| Plan Review Stops For Permit 16040210 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2016-07-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-07-21 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-07-21 |
Time |
15:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2016-06-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-06-27 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-06-27 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2016-06-27 09:46:18 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER ? PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 3RD REVIEW | | | DATE: | | | ACTION: DENIED | | | | | | 1. COMMENTS FROM 2ND REVIEW HAVE NOT BEEN ADDRESSED. | | | SEE PLAN REVIEW COMMENTS FROM 2ND REVIEW AND CORRECT | | | PRIOR TO RE-SUBMITTING. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-05-18 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-06-06 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-05-18 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2016-06-06 15:52:59 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER ? PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-7918 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | DATE: 6/6/16 | | | ACTION: FAIL | | | | | | MAIN HOUSE SCOPE OF WORK CHANGED TO WINDIWS, DOORS AND | | | SIDING. | | | | | | 1. COMPLY WITH HISTORIC REVIEW COMMENTS. | | | 2. PRODUCT APPROVALS SUBMITTED ARE FOR SINGLE HUNG | | | WINDOWS. WINDOW SCHEDULE ON PG. A1 DOES NOT LIST ANY | | | SINGLE HUNG WINDOWS. PROVIDE PRODUCT APPROVALS FOR | | | WINDOWS, DOORS AND SIDING. DESIGNER TO REVIEW AND SIGN | | | PRODUCT APPROVALS. ALL PRODUCT APPROVALS ON WINDOW AND | | | DOOR SCHEDULE ARE EXPIRED. | | | 3. PG T1 INDICATES GOVERNING CODES AS 2008 FBC. CURRENT | | | GOVERNING CODES ARE 2014 FBC 5TH ED. | | | 4. FLOOR PLAN DETAIL ON PLAN SHEET S-1 IS A COPY OF | | | EXPIRED NOA 02-1120-03. | | | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY | | | FAC RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. SPECIFICALLY, PROVIDE WINDOW AND | | | DOOR SUBMITTALS. | | | | | | | | | | | | | | 2016-05-18 14:42:44 | BUILDING PLAN REVIEW | | | W.P.B. PERMIT NO.: 16040210 | | | ADD: 504 50TH ST | | | CONTR: OWNER - STELIOS HIOTIS | | | TEL: 561-419-1258 | | | E-MAIL: ? | | | | | | 2014 FLORIDA BUILDING CODE | | | W/ 2014 WEST PALM BEACH AMENDMENTS | | | TO THE FLORIDA BUILDING CODE, CHPT. 1, ADMINISTRATION | | | | | | 2ND REVIEW | | | DATE: 5/18/16 | | | ACTION: FAILED | | | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | | BELOW. | | | | | | 1. ORIGINAL SOW CHANGED ON 4/19/16 PER SAK. NEW SOW FOR | | | WINDOWS, DOORS AND SIDING ON MAIN HOUSE, ONLY. | | | | | | 2. INCORRECT CODE REFERENCED ON PLANS. CURRENT CODE IS | | | THE 2014 FBC 5TH ED. | | | | | | 3. SELECTED WINDOWS DO NOT COMPLY WITH THE HISTORIC | | | REQUIREMENTS FOR THIS PROPERTY. COMPLY WITH HISTORIC | | | COMMENTS AND RE-APPLY. | | | | | | 4. PROVIDE PRODUCT APPROVALS FOR THOSE ITEMS SUBJECT TO | | | WIND LOAD. (WINDOWS, DOORS, SIDING). | | | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE | | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH | | | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES | | | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE | | | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE | | | FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | | DESIGN. (SEE ALSO SECTION 107.3.5). | | | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY | | | FAC RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. SPECIFICALLY, PROVIDE WINDOW, DOOR | | | AND SIDING SUBMITTALS. | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | BUILDING PLANS EXAMINER ? PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-7918 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-04-19 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-04-19 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-04-19 |
Time |
17:47 |
Sent To |
|
|
| Notes |
| 2016-04-19 17:52:19 | 1ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL | | | | | | SPOKE TO APPLICANT. HE WISHES TO CHANGE THE SCOPE OF | | | WORK ON THIS APPLICATION TO WINDOWS/DOORS, & SIDING FOR | | | THE MAIN STRUCTURE ONLY. ADDITIONAL APPLICATIONS WILL | | | BE SUBMITTED ON THE MAIN HOUSE FOR INTERIOR | | | ALTERATIONS. THE SEPARATE STRUCTURE IS A SEPARATE | | | DEWELLING UNIT. I HAVE EXPLAINED AN OWNER BUILDER | | | APPLICATION CANNOT BE USE AS THE EXEMPTION DOES NOT | | | APPLY. THE PLANS AS SUBMITTED DO NOT MEET MINIMUM | | | CRITERIA FOR THE THE SMALLER SCOPE. PER FBC 107. NO | | | INFFORMATION IS PROVIDED AS TO WINDOW PRODUCTS OR | | | SIDING. | | | | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2016-07-21 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-07-21 |
Time |
17:07 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-07-21 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2016-07-21 17:10:17 | ROUTED TO GEORGE JOHNSON |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2016-06-27 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-06-27 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-06-27 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2016-06-27 13:54:10 | REVIEW 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 561-805-6713 | | | [email protected] | | | | | | PASSED WITH THE FOLLOWING PROVISO | | | | | | - FBC-E R404.1 A MINIMUM OF 75 PERCENT OF THE LAMPS IN | | | PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE | | | HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF THE | | | PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CONTAIN | | | ONLY HIGH EFFICACY LAMPS. | | | | | | - FBC R E4002.14 TAMPER-RESISTANT RECEPTACLES, E3902.13 | | | ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION FOR | | | BRANCH-CIRCUIT EXTENSIONS OR MODIFICATIONS |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-05-18 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
|
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-05-18 |
Time |
11:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-04-06 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-04-06 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-04-06 |
Time |
17:19 |
Sent To |
|
|
| Notes |
| 2016-04-06 17:35:14 | REVIEW 2014 5TH FBC ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 516-805-6713 | | | [email protected] | | | | | | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE | | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | | ELECTRONIC MEDIA DOCUMENTS SHALL BE | | | SUBMITTED WHEN APPROVED BY THE BUILDING OFFICIAL. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY | | | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH | | | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES | | | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE | | | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE | | | FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | | DESIGN. (SEE ALSO SECTION 107.3.5). | | | | | | - MINIMUM REQUIREMENTS OF NEC 406.11 TAMPER RESISTANT | | | RECEPTACLES , NEC 210.12 B AFCI PROTECTION , NEC 210.8 | | | A GFCI PROTECTION, AND SMOKE ALARMS PER RESIDENTIAL | | | CODE 314 & 315. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
5 |
Status |
P |
Date |
2016-07-22 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2016-07-22 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2016-07-22 |
Time |
16:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
4 |
Status |
F |
Date |
2016-07-20 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2016-07-20 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2016-07-20 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2016-07-20 14:13:39 | WINDOWS SHALL BE REPAIRED AS DISCUSSED WITH OWNER. | | | QUESTIONS CONTATC FRIEDERIKE MITTNER AT 822-1457. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
F |
Date |
2016-06-21 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2016-06-21 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2016-06-21 |
Time |
08:17 |
Sent To |
|
|
| Notes |
| 2016-06-21 08:18:27 | 6/21/16 - COA APPLICATION STILL MISSING. PLEASE CONTACT | | | HISTORIC PRESERVATION PLANNER AT 561.822.1457 TO | | | COMPLETE APPLICATION PRIOR TO PERMITTING. |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
F |
Date |
2016-05-17 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2016-05-24 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2016-05-17 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2016-05-24 10:41:56 | 5/24/16 - THIS PROPERTY AND ITS ANCILLARY BUILDINGS ARE | | | CONTRIBUTING RESOURCES TO THE NORTHWOOD HARBOR HISTORIC | | | DISTRICT. APPLICANT PROVIDED NEW PRODUCT APPROVAL FORMS | | | FOR SINGLE-HUNG ALUMINUM WINDOWS; HOWEVER, APPLICANT | | | MUST ALSO SUBMIT A COA FOR THE EXPANDED SCOPE OF WORK | | | (REMOVAL OF HISTORIC WOOD FRAME WINDOWS, EXTERIOR | | | SIDING REPLACEMENT, REMOVAL OF FIREPLACE PER PLANS, | | | DEMOLITION OF INTERIOR). INTENDED CHANGES AND THE | | | SIGNIFICANT LOSS OF ORIGINAL FABRIC WILL REQUIRE | | | APPROVAL FROM THE HISTORIC PRESERVATION BOARD. PLEASE | | | VISIT OUR WEBSITE TO REVIEW THE COA APPLICATION AND | | | MATERIALS NEEDED FOR SUBMISSION: HTTP://WPB.ORG/DEPARTM | | | ENTS/DEVELOPMENT-SERVICES/HISTORIC-PRESERVATION/APPLICA | | | TIONS?PAGE=2 QUESTIONS MAY BE DIRECTED TO DESIREE | | | ESTABROOK, HISTORIC PRESERVATION PLANNER, 561.822.1428. | | 2016-05-17 13:43:57 | 5/17/16 - NO PHOTOS OF HOUSE PROVIDED - PER GOOGLE | | | STREETVIEW, WINDOWS APPEAR TO BE ORIGINAL 6/1 | | | DOUBLE-HUNG WOOD SASH. APPLICANT IS REQUESTING 'SERIES | | | 70 EXTRUDED VINYL SINGLE HUNG WINDOWS' - VINYL PRODUCTS | | | ARE NOT APPROVED WITHIN HISTORIC DISTRICTS. PLEASE | | | SUBMIT A COA (FOUND HERE: HTTP://WPB.ORG/DEPARTMENTS/DE | | | VELOPMENT-SERVICES/HISTORIC-PRESERVATION/APPLICATIONS?P | | | AGE=2) FOR THE PROPOSED WORK. QUESTIONS MAY BE DIRECTED | | | TO DESIREE ESTABROOK, HISTORIC PRESERVATION PLANNER, | | | 561.822.1428 |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-04-18 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2016-04-18 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2016-04-18 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2016-04-18 11:09:51 | 4-18-2016 - AS A CONTRIBUTING PROPRETY TO THE NORTHWOOD | | | HABOR HISTORIC DISTRICT, MORE DETAIL IS REQUIRED | | | REGARDING THE PROPOSED WORK. VINYL WINDOWS ARE NOT | | | PERMITTED WITHIN HISTORIC DISTRICTS UNLESS REVIEWED AND | | | APPROVED BY THE HISTORIC PRESERVATION BOARD. | | | RESUBMITTAL SHOULD INCLUDE PHOTOS OF THE PROPERTY AND | | | SPECIFY THE EXACT AREAS OF WINDOW REPLACEMENT AND | | | CHANGE IN MATERIAL. IF APPLICANT HAS QUESTIONS, PLEASE | | | CONTACT DESIREE ESTABROOK @ 561.822.1428 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2016-07-25 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-07-25 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-07-18 |
Time |
12:43 |
Sent To |
|
|
| Notes |
| 2016-07-20 12:43:48 | LIBRARY | | | TRAVELLING WITH 16040212 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-06-27 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-06-27 |
Time |
14:00 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-06-09 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2016-06-10 10:41:05 | R23 | | | **TRAVELLING WITH 16040212** |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-06-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-06-06 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-05-16 |
Time |
15:48 |
Sent To |
|
|
| Notes |
| 2016-05-16 15:48:31 | RESUB ROUTED TO DESTABRO VIA ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-04-19 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-04-19 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-04-05 |
Time |
14:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2016-07-25 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-07-25 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-07-25 |
Time |
11:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2016-06-27 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-06-21 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-06-21 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2016-06-21 14:34:18 | 2ND REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: COMMENTS FROM FIRST REVIEW NOT | | | ADDRESSED 2ND REQUEST | | | | | | 1. SHT. A-1 PROPOSED LAUNDRY IT APPEARS THAT YOU HAVE | | | WASHING MACHINE MARKED AS D.W FOR DISHWASHER PLEASE | | | CLARIFY. PER WPB AMEND. TO FBC 107.2.1 | | | | | | 2. SHT A-1 RISER DIAGRAM THE WASHING MACHINE SHALL NOT | | | CONNECT DIRECTLY TO SANITARY IT MUST DRAIN INTO A STAND | | | PIPE WITH AN AIR BREAK. PER FBC PL SEC. P2718.1 | | | | | | 3. SHT A-1 RISER DIAGRAM THE DISHWASHER DRAIN SHALL NOT | | | CONNECT DIRECTLY TO SANITARY IT HAS TO CONNECT TO SINK | | | DRAIN OR DISPOSAL WITH AN AIR BREAK. PER FBC PL SEC. | | | P2717.1 | | | | | | 4. IT IS UNCLEAR HOW THE VENTS FOR THE TOILETS AND | | | SHOWERS ARE CONNECTING TO THE SANITARY , YOU DO NOT | | | NEED SEPARATE VENTS FOR THESE FIXTURES THE VENT ON THE | | | LAVATORY SERVES AS THE VENT FOR THE WHOLE BATHROOM | | | GROUP PLEASE CLARIFY. PER WPB AMEND. TO FBC 107.2.1 | | | | | | 5. THE LAUNDRY SHALL TIE IN DOWNSTREAM OF THE BATHROOM | | | GROUP. PER FBC PL SEC. P3108.1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-05-31 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-05-31 |
Time |
17:43 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-05-31 |
Time |
17:43 |
Sent To |
|
|
| Notes |
| 2016-06-21 14:33:33 | REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: COMMENTS FROM FIRST REVIEW NOT | | | ADDRESSED 2ND REQUEST | | | | | | 1. SHT. A-1 PROPOSED LAUNDRY IT APPEARS THAT YOU HAVE | | | WASHING MACHINE MARKED AS D.W FOR DISHWASHER PLEASE | | | CLARIFY. PER WPB AMEND. TO FBC 107.2.1 | | | | | | 2. SHT A-1 RISER DIAGRAM THE WASHING MACHINE SHALL NOT | | | CONNECT DIRECTLY TO SANITARY IT MUST DRAIN INTO A STAND | | | PIPE WITH AN AIR BREAK. PER FBC PL SEC. P2718.1 | | | | | | 3. SHT A-1 RISER DIAGRAM THE DISHWASHER DRAIN SHALL NOT | | | CONNECT DIRECTLY TO SANITARY IT HAS TO CONNECT TO SINK | | | DRAIN OR DISPOSAL WITH AN AIR BREAK. PER FBC PL SEC. | | | P2717.1 | | | | | | 4. IT IS UNCLEAR HOW THE VENTS FOR THE TOILETS AND | | | SHOWERS ARE CONNECTING TO THE SANITARY , YOU DO NOT | | | NEED SEPARATE VENTS FOR THESE FIXTURES THE VENT ON THE | | | LAVATORY SERVES AS THE VENT FOR THE WHOLE BATHROOM | | | GROUP PLEASE CLARIFY. PER WPB AMEND. TO FBC 107.2.1 | | | | | | 5. THE LAUNDRY SHALL TIE IN DOWNSTREAM OF THE BATHROOM | | | GROUP. PER FBC PL SEC. P3108.1 | | 2016-05-31 17:50:20 | 1ST REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHT. A-1 PROPOSED LAUNDRY IT APPEARS THAT YOU HAVE | | | WASHING MACHINE MARKED AS D.W FOR DISHWASHER PLEASE | | | CLARIFY. PER WPB AMEND. TO FBC 107.2.1 | | | | | | 2. SHT A-1 RISER DIAGRAM THE WASHING MACHINE SHALL NOT | | | CONNECT DIRECTLY TO SANITARY IT MUST DRAIN INTO A STAND | | | PIPE WITH AN AIR BREAK. PER FBC PL SEC. P2718.1 | | | | | | 3. SHT A-1 RISER DIAGRAM THE DISHWASHER DRAIN SHALL NOT | | | CONNECT DIRECTLY TO SANITARY IT HAS TO CONNECT TO SINK | | | DRAIN OR DISPOSAL WITH AN AIR BREAK. PER FBC PL SEC. | | | P2717.1 | | | | | | 4. IT IS UNCLEAR HOW THE VENTS FOR THE TOILETS AND | | | SHOWERS ARE CONNECTING TO THE SANITARY , YOU DO NOT | | | NEED SEPARATE VENTS FOR THESE FIXTURES THE VENT ON THE | | | LAVATORY SERVES AS THE VENT FOR THE WHOLE BATHROOM | | | GROUP PLEASE CLARIFY. PER WPB AMEND. TO FBC 107.2.1 | | | | | | 5. THE LAUNDRY SHALL TIE IN DOWNSTREAM OF THE BATHROOM | | | GROUP. PER FBC PL SEC. P3108.1 |
|
|