| Plan Review Stops For Permit 16040173 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2016-04-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-04-13 |
Time |
07:59 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-04-13 |
Time |
07:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-04-29 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-04-29 |
Time |
11:35 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-04-29 |
Time |
11:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2016-04-13 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-04-08 |
Time |
05:21 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-04-13 |
Time |
07:44 |
Sent To |
|
|
| Notes |
| 2016-04-08 05:25:35 | INITIAL ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA EXISTING BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 NEC | | | COMMENTS: | | | | | | 1. PROVISO- SHOW THE MOTORIZED SHADES IN MASTER BATH | | | ABOVE TUB AREA TO BE HARDWIRED NOT A RECEPTACLE PER NEC | | | 406.9C. | | | 2. FEEL FREE TO CONTACT ME WITH ANY QUESTIONS OR | | | CONCERNS. | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2016-04-27 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-04-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-04-27 |
Time |
09:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2016-04-06 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-04-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-04-06 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2016-04-06 16:33:16 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1. SHEET A 1 - THERE IS NO REFERENCE TO THE APPLICABLE | | | FIRE CODE INDICATED. | | | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | | 5TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING | | | THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | | APPLICABLE CODES OR STANDARDS. | | | FIRE SPRINKLER WORK SHALL COMPLY WITH THE REQUIREMENTS | | | OF NFPA 13, 2010 EDITION. | | | FIRE ALARM WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 72, 2010 EDITION. | | | CONSTRUCTION WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 241, 2009 EDITION. | | | | | | 2. SHEET A 2 - THE EXTENT OF THE REMODEL OR REVISION IS | | | UNCLEAR AND DOES NOT INDICATE SUFFICIENT DETAIL TO | | | ADDRESS LIFE SAFETY SYSTME CONCERNS OF THE PROPOSED | | | PROJECT. | | | | | | THE NATURE OF THE REMODEL REQUIRES AN EVALUATION OF ANY | | | FIRE ALARM AND FIRE SPRINKLER SYSTEM EQUIPMENT FOR CODE | | | COVERAGE AND COMPLIANCE. ANY REMOVAL AND/OR | | | CONSTRUCTION OF WALLS REQUIRE AN EVALUATION OF THE | | | EXISTING EQUIPMENT. | | | | | | IF EXISTING, THE FIRE ALARM AND FIRE SPRINKLER SYSTEM | | | SHALL REMAIN ACTIVE THROUGHOUT THE CONSTRUCTION PERIOD. | | | | | | ANY AND ALL WORK ON THE FIRE ALARM SYSTEM SHALL BE DONE | | | UNDER SEPARATE SHOP DRAWINGS AND BY CERTIFIED LIFE | | | SAFETY CONTRACTORS. | | | | | | ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEM, EXCEEDS 4 | | | HOURS, A FIRE WATCH SHALL BE IMPLEMENTED AND MAINTAINED | | | UNTIL FULL AND COMPLETE PROTECTION IS RETURNED. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-05-02 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2016-05-02 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2016-04-22 |
Time |
09:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-04-18 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-04-18 |
Time |
03:54 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-04-05 |
Time |
14:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2016-04-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-04-13 |
Time |
07:49 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-04-13 |
Time |
07:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2016-05-02 |
|
|
Cont ID |
|
| Sent By |
jvalido |
Date |
2016-05-02 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
jvalido |
Date |
2016-05-02 |
Time |
08:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-04-06 |
|
|
Cont ID |
|
| Sent By |
jvalido |
Date |
2016-04-06 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
jvalido |
Date |
2016-04-06 |
Time |
08:58 |
Sent To |
|
|
| Notes |
| 2016-04-06 09:59:49 | 2014 FBC MECHANICAL | | | | | | 601.5 - BALANCED RETURN AIR. | | | PROVIDE RETURN AIR FOR ALL BEDROOMS. | | | | | | 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS | | | SHOW RETURN AIR DUCTWORK (TO INCLUDE DUCT DIMENSIONS, | | | CFM QUANTITIES AND DIFFUSER SIZES) |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2016-05-02 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-05-02 |
Time |
04:13 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-05-02 |
Time |
03:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2016-04-18 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-04-18 |
Time |
03:54 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-04-18 |
Time |
03:41 |
Sent To |
|
|
| Notes |
|
|