Plan Review Details - Permit 16040173
Plan Review Stops For Permit 16040173
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2016-04-13 Cont ID  
Sent By jwitmer Date 2016-04-13 Time 07:59 Rev Time 0.00
Received By jwitmer Date 2016-04-13 Time 07:30 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-04-29 Cont ID  
Sent By vperez Date 2016-04-29 Time 11:35 Rev Time 0.00
Received By vperez Date 2016-04-29 Time 11:35 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-04-13 Cont ID  
Sent By vperez Date 2016-04-08 Time 05:21 Rev Time 0.00
Received By vperez Date 2016-04-13 Time 07:44 Sent To  
Notes
2016-04-08 05:25:35INITIAL ELECTRICAL PLAN REVIEW
  
 APPLICABLE CODES IN EFFECT:
 FLORIDA EXISTING BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70- 2011 NEC
 COMMENTS:
  
 1. PROVISO- SHOW THE MOTORIZED SHADES IN MASTER BATH
 ABOVE TUB AREA TO BE HARDWIRED NOT A RECEPTACLE PER NEC
 406.9C.
 2. FEEL FREE TO CONTACT ME WITH ANY QUESTIONS OR
 CONCERNS.
 VALENTINO PEREZ
 ELECTRICAL PLANS EXAMINER II
 561-805-6717
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2016-04-27 Cont ID  
Sent By pleduc Date 2016-04-27 Time   Rev Time 0.00
Received By pleduc Date 2016-04-27 Time 09:58 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2016-04-06 Cont ID  
Sent By pleduc Date 2016-04-06 Time   Rev Time 0.00
Received By pleduc Date 2016-04-06 Time 16:26 Sent To  
Notes
2016-04-06 16:33:16THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1. SHEET A 1 - THERE IS NO REFERENCE TO THE APPLICABLE
 FIRE CODE INDICATED.
  
 THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE
 5TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING
 THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER
 APPLICABLE CODES OR STANDARDS.
 FIRE SPRINKLER WORK SHALL COMPLY WITH THE REQUIREMENTS
 OF NFPA 13, 2010 EDITION.
 FIRE ALARM WORK SHALL COMPLY WITH THE REQUIREMENTS OF
 NFPA 72, 2010 EDITION.
 CONSTRUCTION WORK SHALL COMPLY WITH THE REQUIREMENTS OF
 NFPA 241, 2009 EDITION.
  
 2. SHEET A 2 - THE EXTENT OF THE REMODEL OR REVISION IS
 UNCLEAR AND DOES NOT INDICATE SUFFICIENT DETAIL TO
 ADDRESS LIFE SAFETY SYSTME CONCERNS OF THE PROPOSED
 PROJECT.
  
 THE NATURE OF THE REMODEL REQUIRES AN EVALUATION OF ANY
 FIRE ALARM AND FIRE SPRINKLER SYSTEM EQUIPMENT FOR CODE
 COVERAGE AND COMPLIANCE. ANY REMOVAL AND/OR
 CONSTRUCTION OF WALLS REQUIRE AN EVALUATION OF THE
 EXISTING EQUIPMENT.
  
 IF EXISTING, THE FIRE ALARM AND FIRE SPRINKLER SYSTEM
 SHALL REMAIN ACTIVE THROUGHOUT THE CONSTRUCTION PERIOD.
  
 ANY AND ALL WORK ON THE FIRE ALARM SYSTEM SHALL BE DONE
 UNDER SEPARATE SHOP DRAWINGS AND BY CERTIFIED LIFE
 SAFETY CONTRACTORS.
  
 ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEM, EXCEEDS 4
 HOURS, A FIRE WATCH SHALL BE IMPLEMENTED AND MAINTAINED
 UNTIL FULL AND COMPLETE PROTECTION IS RETURNED.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-05-02 Cont ID  
Sent By cpuell Date 2016-05-02 Time 09:19 Rev Time 0.00
Received By cpuell Date 2016-04-22 Time 09:15 Sent To  
Notes
2016-04-22 09:15:39B22

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-04-18 Cont ID  
Sent By tklarge Date 2016-04-18 Time 03:54 Rev Time 0.00
Received By tklarge Date 2016-04-05 Time 14:49 Sent To  
Notes
2016-04-05 14:49:57B12

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2016-04-13 Cont ID  
Sent By jwitmer Date 2016-04-13 Time 07:49 Rev Time 0.00
Received By jwitmer Date 2016-04-13 Time 07:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2016-05-02 Cont ID  
Sent By jvalido Date 2016-05-02 Time 09:09 Rev Time 0.00
Received By jvalido Date 2016-05-02 Time 08:38 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-04-06 Cont ID  
Sent By jvalido Date 2016-04-06 Time 10:00 Rev Time 0.00
Received By jvalido Date 2016-04-06 Time 08:58 Sent To  
Notes
2016-04-06 09:59:492014 FBC MECHANICAL
  
 601.5 - BALANCED RETURN AIR.
 PROVIDE RETURN AIR FOR ALL BEDROOMS.
  
 107.2.1 - INFORMATION ON CONSTRUCTION DOCUMENTS
 SHOW RETURN AIR DUCTWORK (TO INCLUDE DUCT DIMENSIONS,
 CFM QUANTITIES AND DIFFUSER SIZES)

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-05-02 Cont ID  
Sent By tklarge Date 2016-05-02 Time 04:13 Rev Time 0.00
Received By tklarge Date 2016-05-02 Time 03:57 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-04-18 Cont ID  
Sent By tklarge Date 2016-04-18 Time 03:54 Rev Time 0.00
Received By tklarge Date 2016-04-18 Time 03:41 Sent To  
Notes
***NONE***