| 2016-04-04 09:33:47 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 16031479 |
| | ADD: 1501 N. AUSTRALIAN BLVD. |
| | CONT: HI-TECH ROOFING & SHEET METAL, INC. |
| | TEL: 561-586-3110 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: MON. APRIL 04/2016 |
| | ACTION: DENIED |
| | |
| | 1) UNDER THE SCOPE OF WORK THE DOCUMENT INDICATES THE |
| | CONTRACTOR SHAL REPAIR OR REPLACE PORTIONS OF THE ROOF |
| | MEMBRANE COVERING. |
| | PLEASE UPDATE NOTES THE ROOF WILL EITHER BE REPAIRED. |
| | THE ROOF WILL BE REPLACED, THE WORD OR CANNOT BE USED |
| | IN THE DESCRIPTION OF WORK. PLEASE REVIEW 2014 FLORIDA |
| | BUILDING CODE W 2014 WEST PALM BEACH AMENDMENTS TO THE |
| | FLORIDA BUILDING CODE, CHAPTER 1, ADMINISTRATION |
| | SECTION 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | SUCH DRAWINGS AND SPECIFICATIONS SHALL CONTAIN |
| | INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, AS TO |
| | THE QUALITY OF MATERIALS, WHERE QUALITY IS ESSENTIAL TO |
| | CONFORMITY WITH THE TECHNICAL CODES. SUCH INFORMATION |
| | SHALL BE SPECIFIC, AND THE TECHNICAL CODES SHALL NOT BE |
| | CITED AS A WHOLE OR IN PART, NOR SHALL THE TERM "LEGAL" |
| | OR ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC |
| | INFORMATION. |
| | |
| | 2) PLEASE PROVIDE THE SQUARE FOOTAGE OF THE ROOF WHERE |
| | WORK IS TO OCCUR. THE SQUARE FOOTAGE AREA OF WORK IS |
| | OVER THE 255 SQ. FT LISTED IN THE 11 WORK AREAS LISTED |
| | ON EXHIBIT A. ITEM (I) ALONE IS 255 SQUARE FEET ALONE, |
| | 85 SQ. FT. X3= 255 SQ. FT. 2014 FBC-EXISITNG BUILDING |
| | CODE |
| | 708.1.1 NOT MORE THAN 25 PERCENT OF THE TOTAL ROOF AREA |
| | OR ROOF SECTION OF ANY EXISTING BUILDING OR STRUCTURE |
| | SHALL BE REPAIRED, REPLACED OR RECOVERED IN ANY |
| | 12-MONTH PERIOD UNLESS THE ENTIRE ROOFING SYSTEM OR |
| | ROOF SECTION CONFORMS TO REQUIREMENTS OF THIS CODE. |
| | |
| | 3) EXHIBIT A NOTE (F) INDICATES THE REMOVAL OF CLEAN |
| | AND RESEAT/ RESEAL ALL ROOF DRAINS (6). PLEASE EXPLAIN |
| | IF THE MATERIALS USED IN SEATING OF THE ROOF DRAINS ARE |
| | USED? REMOVAL OF, CLEAN AND RESEAT SOUNDS LIKE THEY ARE |
| | USED MATERIALS? |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | 104.9.1 USED MATERIALS AND EQUIPMENT. THE USE OF USED, |
| | RECYCLED, OR RECLAIMED MATERIALS WHICH MEET THE |
| | REQUIREMENTS OF THIS CODE FOR NEW MATERIALS IS |
| | PERMITTED. USED EQUIPMENT AND DEVICES SHALL NOT BE |
| | REUSED UNLESS APPROVED BY THE BUILDING OFFICIAL. |
| | |
| | 2014 FBC-EXISITING BLDG. CODE 602.2 NEW AND REPLACEMENT |
| | MATERIALS. EXCEPT AS OTHERWISE REQUIRED OR PERMITTED BY |
| | THIS CODE, MATERIALS PERMITTED BY THE APPLICABLE CODE |
| | FOR NEW CONSTRUCTION SHALL BE USED. LIKE MATERIALS |
| | SHALL BE PERMITTED FOR REPAIRS AND ALTERATIONS, |
| | PROVIDED NO DANGEROUS OR UNSAFE CONDITION, AS DEFINED |
| | IN CHAPTER 2, IS CREATED. HAZARDOUS MATERIALS, SUCH AS |
| | ASBESTOS AND LEAD-BASED PAINT, SHALL NOT BE USED WHERE |
| | THE CODE FOR NEW CONSTRUCTION WOULD NOT PERMIT THEIR |
| | USE IN BUILDINGS OF SIMILAR OCCUPANCY, PURPOSE AND |
| | LOCATION. |
| | |
| | 107.2.1.2 FOR ROOF ASSEMBLIES REQUIRED BY THE CODE, THE |
| | CONSTRUCTION DOCUMENTS SHALL ILLUSTRATE, DESCRIBE AND |
| | DELINEATE THE TYPE OF ROOFING SYSTEM, MATERIALS, |
| | FASTENING REQUIREMENTS, FLASHING REQUIREMENTS AND WIND |
| | RESISTANCE RATING THAT ARE REQUIRED TO BE INSTALLED. |
| | PRODUCT EVALUATION AND INSTALLATION SHALL INDICATE |
| | COMPLIANCE WITH THE WIND CRITERIA REQUIRED FOR THE |
| | SPECIFIC SITE OR A STATEMENT BY AN ARCHITECT OR |
| | ENGINEER FOR THE SPECIFIC SITE MUST BE SUBMITTED WITH |
| | THE CONSTRUCTION DOCUMENTS. |
| | |
| | 4) THE EXHIBIT A NOTE (E) INDICATES INSTALL ADDITIONAL |
| | HVAC CURB FLASHING PLEASE PROVIDE COMPLIANCE WITH: |
| | 107.2.1.2 FOR ROOF ASSEMBLIES REQUIRED BY THE CODE, THE |
| | CONSTRUCTION DOCUMENTS SHALL ILLUSTRATE, DESCRIBE AND |
| | DELINEATE THE TYPE OF ROOFING SYSTEM, MATERIALS, |
| | FASTENING REQUIREMENTS, FLASHING REQUIREMENTS AND WIND |
| | RESISTANCE RATING THAT ARE REQUIRED TO BE INSTALLED. |
| | PRODUCT EVALUATION AND INSTALLATION SHALL INDICATE |
| | COMPLIANCE WITH THE WIND CRITERIA REQUIRED FOR THE |
| | SPECIFIC SITE OR A STATEMENT BY AN ARCHITECT OR |
| | ENGINEER FOR THE SPECIFIC SITE MUST BE SUBMITTED WITH |
| | THE CONSTRUCTION DOCUMENTS. |
| | |
| | 5) NOTES B & C BOTH DEAL WITH THE HVAC DUCTWORK STANDS |
| | AND HVACMEMBRANE WRAPS AROUND THE HVAC SUPPLY AND |
| | RETURNS. AGAIN PLEASE SUPPLY DOCUMENTS THAT ILLUSTRATE, |
| | DESCRIBE AND DELINEATE THE TYPE OF ROOFING SYSTEM, |
| | MATERIALS, FASTENING REQUIREMENTS, FLASHING |
| | REQUIREMENTS AND WIND RESISTANCE RATING THAT ARE |
| | REQUIRED TO BE INSTALLED. PRODUCT EVALUATION AND |
| | INSTALLATION SHALL INDICATE COMPLIANCE WITH THE WIND |
| | CRITERIA REQUIRED FOR THE SPECIFIC SITE OR A STATEMENT |
| | BY AN ARCHITECT OR ENGINEER FOR THE SPECIFIC SITE MUST |
| | BE SUBMITTED WITH THE CONSTRUCTION DOCUMENTS.107.2.1.2. |
| | |
| | 6) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A |
| | RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |
| | |