| Plan Review Stops For Permit 16031458 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2016-05-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-05-10 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-05-10 |
Time |
15:50 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-05-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-05-02 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-05-02 |
Time |
15:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-04-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-04-12 |
Time |
12:21 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-04-12 |
Time |
11:50 |
Sent To |
|
|
| Notes |
| 2016-04-12 12:24:58 | 1ST REVIEW: FBC 2014 5TH ED | | | CHRISTOPHER S. THROOP, C.B.O. | | | BLDG. PLANS EXAMINER ? PX3169 | | | (561) 805-6718 | | | [email protected] | | | | | | 1. STRUCTURAL ENGINEER TO SIGN AND SEAL PLAN SHEET | | | S-1.0 | | | | | | FBC-107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF | | | CONSTRUCTION DOCUMENTS - THE CONSTRUCTION DOCUMENTS | | | SHALL BE PREPARED BY A REGISTERED DESIGN PROFESSIONAL | | | WHERE REQUIRED BY CHAPTER 471, FLORIDA STATUTES& 61G15 | | | FLORIDA ADMINISTRATIVE CODE OR CHAPTER 481, FLORIDA | | | STATUTES& 61G1 FLORIDA ADMINISTRATIVE CODE, THEN HE OR | | | SHE SHALL AFFIX HIS OR HER OFFICIAL SEAL TO SAID | | | DRAWINGS, SPECIFICATIONS AND ACCOMPANYING DATA, AS | | | REQUIRED BY FLORIDA STATUTE. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-05-02 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-05-02 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-05-02 |
Time |
16:43 |
Sent To |
I |
|
| Notes |
| 2016-05-02 17:14:25 | ALL PREVIOUSLY MENTIONED COMMENTS HAVE BEEN | | | SATISFACTORILY ADDRESSED. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-04-01 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-04-01 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-04-01 |
Time |
09:29 |
Sent To |
B |
|
| Notes |
| 2016-04-01 11:46:10 | FAILED 1ST ELECTRICAL REVIEW AS INDICATED BELOW | | | REVIEWED FOR COMPLIANCE WITH: | | | 5TH EDITION FBC 2014 AND NFPA 70 2011 (NEC) | | | | | | CORRECTIONS REQUIRED: | | | 1. THE MANUFACTURER'S SPECS ON THE PROPOSED UNITS | | | INDICATE AN OPERATING VOLTAGE OF 208V/3 PHASE; | | | ACCORDING TO THE MARKINGS ON THE PLANS, THE AVAILABLE | | | VOLTAGE IS 277/480V/3 PHASE. VERIFY EXISTING CONDITIONS | | | TO CONFIRM COMPATIBILITY OF PROPOSED UNITS. | | | 2. THE SAME MANUFACTURER'S SPEC SHEET SPECIFICALLY | | | CALLS FOR THE USE OF COPPER CONDUCTORS W/A 90 DEGREE | | | INSULATION. THE PROVIDED RISER DIAGRAM OFFERS THE | | | UNACCEPTABLE OPTION OF USING ALUMINUM CONDUCTORS, | | | CONTRARY TO MANUFACTURER'S SPECS. | | | 3. THE RISERS AS SHOWN FAIL TO INCLUDE THE REQUIRED | | | 115V/20A CIRCUITS FOR THE HEATERS AND CONTROL PANEL | | | POWER SUPPLY. | | | 4. PROVIDE LOAD CALCS TAKING INTO ACCOUNT THE REQUIRED | | | DERATION FOR CONDUIT FILL AND AMBIENT TEMPERATURE | | | EXPOSURE. MAKE SURE YOU INDICATE THE REQUIRED 90 DEGREE | | | CONDUCTOR INSULATION. | | | 5. ACCORDING TO THE FLOOR PLAN THE EXISTING SERVICE | | | OUTLET IS BEYOND THE MAXIMUM 25 FEET MANDATED BY THE | | | NEC. | | | 6. THE NEW OUTLET SHALL COMPLY WITH NEC406.12 WHEREAS | | | THE ACTUAL DEVICE IS LISTED WEATHER-RESISTANT. | | | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | | RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER | | | (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER | | | WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD | | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID | | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | | GREATLY APPRECIATED. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON'T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU, | | | MIKE ALBARRAN | | | ELECTRICAL PLANS EXAMINER | | | PH: 561-805-6746 | | | EMAIL: [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-05-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-05-11 |
Time |
06:59 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-05-10 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2016-05-10 11:22:51 | RESUB ROUTED TO CTHROOP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-05-02 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-05-02 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-04-20 |
Time |
13:13 |
Sent To |
|
|
| Notes |
| 2016-05-02 17:38:21 | 5/2/16 PASSED ELECTRICAL REVIEW BUT FAILED MECHANICAL. | | | CONTRACTOR NOTIFIED VIA EMAIL. FILE SENT TO LARGE | | | DENIED DRAWER "S". MA | | 2016-04-20 13:14:49 | B12 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-04-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-04-12 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-03-31 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2016-03-31 15:11:51 | ROUTED TO MECHANICAL |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2016-05-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-05-11 |
Time |
06:57 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-05-11 |
Time |
06:57 |
Sent To |
|
|
| Notes |
| 2016-05-11 06:59:07 | MECHANICAL PROVISOS: | | | | | | 1) WELDER'S CERTIFICATE AND WELDING PROCEDURE | | | SECIFICATION MUST BE ON-SITE AT TIME OF INSPECTION. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2016-05-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-05-02 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-05-02 |
Time |
15:42 |
Sent To |
|
|
| Notes |
| 2016-05-02 15:42:54 | OPENED M-STOP BY MISTAKE. CST |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2016-04-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-04-26 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-04-26 |
Time |
11:02 |
Sent To |
|
|
| Notes |
| 2016-04-26 11:06:43 | 1ST REVIEW: FBC 2014 MECHANICAL | | | PERMIT #16031458 | | | 4/26/16 | | | | | | 1) PROVIDE A COMMISSIONING PLAN IN COMPLIANCE WITH | | | SECTION C408.2 AND C408.2.3.1 FBC-14 ENERGY | | | CONSERVATION | | | 2) INDICATE THE CLEARANCE HEIGHT FROM THE FINISHED ROOF | | | SURFACE TO THE BOTTOM OF THE SUPPORT STRUCTURE- TABLE | | | 1509.6.5 FBC-14 BUILDING. | | | 3) PROVIDE ENGINEERED ATTACHMENT DETAILS FOR MOUNTING | | | THE CHILLERS TO THE NEW AND RE-FURBISHED SUPPORT | | | PLATFORM- SECTION 301.15 FBC-14 MECHANICAL. | | | 4) PROVIDE GUARD AND HANDRAIL DETAILS FOR THE EQUIPMENT | | | PLATFORMS- SECTIONS 1012 & 1013 FBC-14 BUILDING. | | | 4) PROVIDE A SITE PLAN SHOWING THE TEMPORARY LOCATION | | | OF OF THE CHILLER ON THE NORTH GRADE AND INCLUDE | | | DETAILS FOR PROTECTION OF THE EQUIPMENT AND COMPONENTS | | | FROM VEHICULAR IMPACT, AND SAFE GUARDS TO PROTECT THE | | | PUBLIC- SECTIONS 303.4 FBC-14 MECHANICAL, AND 3301.2 | | | FBC-14 BUILDING. | | | 5) PROVIDE A TEMPORARY HYDRONIC PIPING PLAN INDICATING | | | THE PIPING RUNS, PIPE ANCHORAGE AND SUPPORT, AND | | | PROTECTIONS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-03-31 |
|
|
Cont ID |
|
| Sent By |
jvalido |
Date |
2016-03-31 |
Time |
19:18 |
Rev Time |
0.00 |
| Received By |
jvalido |
Date |
2016-03-31 |
Time |
18:58 |
Sent To |
E |
|
| Notes |
| 2016-03-31 19:18:31 | 107.1 - PROVIDE OFFICIAL SEAL AND SIGNATURE TO | | | STRUCTURAL PLANS. |
|
|