Plan Review Details - Permit 16031325
| Plan Review Stops For Permit 16031325 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2016-04-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-04-07 |
Time |
06:42 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-04-07 |
Time |
06:30 |
Sent To |
|
|
| Notes |
| 2016-04-07 06:42:51 | BUILDING PROVISO: IF WOOD FRAMING IS TO BE USED, TYPE | | | I/ TYPE II | | | BUILDING.2014 FBC-B 603.1.1.1 FIRE RETARDANT-TREATED | | | WOOD. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-04-13 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-04-13 |
Time |
19:40 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-04-13 |
Time |
19:30 |
Sent To |
I |
|
| Notes |
| 2016-04-13 19:44:30 | APPROVED WITH PROVISO AS NOTED ON PLANS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-03-30 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-03-30 |
Time |
19:12 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-03-30 |
Time |
19:12 |
Sent To |
|
|
| Notes |
| 2016-03-30 19:12:33 | ELECTRICAL REVIEW COMMENTS | | | REVIEWED FOR COMPLIANCE WITH: | | | 5TH EDITION FBC 2014, NFPA 70 2011 (NEC) | | | | | | CORRECTIONS REQUIRED: | | | 1. BEING THE FIRST REVIEWER I FAILED THIS PERMIT AS | | | STATED BELOW. IF PASSED BY ALL OTHER TRADES I WILL | | | PROVISO MY REVIEW OTHERWISE CORRECT ACCORDINGLY AND | | | RESUBMIT. | | | 2. THE MANUFACTURER SPECS SUBMITTED WITH THIS HYDRO | | | MASSAGE TUB DOES NOT COMPLY WITH THE CHANGES OF SECTION | | | 680.73 OF THE NEC. | | | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | | RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER | | | (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER | | | WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD | | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID | | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | | GREATLY APPRECIATED. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU, | | | MIKE ALBARRAN | | | ELECTRICAL PLANS EXAMINER | | | PH: 561-805-6746 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-04-13 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-04-13 |
Time |
19:43 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-03-29 |
Time |
15:42 |
Sent To |
|
|
| Notes |
| 2016-04-13 19:43:49 | 4/13/16 PASSED ELECTRICAL REVIEW WITH PROVISO AS NOTED. | | | CONTRACTOR NOTIFIED VIA EMAIL. FILE SENT TO SMALL READY | | | BIN P. MA | | 2016-03-29 15:42:31 | B09 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2016-04-13 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-04-13 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-04-13 |
Time |
12:03 |
Sent To |
|
|
| Notes |
|
|
|