|
 |
 |
 |
 |
 |
Plan Review Details - Permit 16031303
| Plan Review Stops For Permit 16031303 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2016-04-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-04-11 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-04-11 |
Time |
08:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2016-03-31 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-03-31 |
Time |
07:23 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-03-31 |
Time |
07:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-04-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-04-13 |
Time |
06:51 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-04-12 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2016-04-12 16:26:12 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-04-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-04-11 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-03-28 |
Time |
15:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2016-04-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-04-13 |
Time |
06:52 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-04-13 |
Time |
06:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-03-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-03-31 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-03-31 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2016-03-31 17:01:28 | 1ST REVIEW: FBC 2014 MECHANICAL | | | REVISION PERMIT #16031303 | | | PERMIT #16020244 | | | 3/31/16 | | | | | | 1) SHEET M-1: INDICATE THE CFM SUPPLY FOR THE 12X8 | | | DIFFUSERS IN THE CONFERENCE ROOM, AND THE 10X8 IN THE | | | PM3 ROOM. | | | 2) M-1: THE 8" FLEX DUCTS SUPPLYING AIR TO THE ALLEN | | | AND PRIVATE OFFICE ROOMS NEED TO REMAIN SIZED AT 9" AS | | | THE ORIGINAL PLAN INDICATED. | | | 3) M-1: SHOW DOOR OPENINGS INTO THE KITCHENETTE, AND | | | STORAGE-3 ROOMS. | | | 4) A-1 & M-1: THE WOOD LOUVERED DOOR FOR STORAGE ROOM-3 | | | IS NOT IN COMPLIANCE WITH SECTION C403.2.7.2 FBC-14 | | | ENERGY CONSERVATION. PROVIDE A NON-COMBUSTIBLE DOOR. | | | 5) THE PLANS DON'T CLEARLY SHOW HOW SUPPLY AIR IS BEING | | | RETRUNED TO SYSTEM B: PLEASE CLARIFY. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |