Plan Review Details - Permit 16031253
| Plan Review Stops For Permit 16031253 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-05-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-05-20 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-05-20 |
Time |
09:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-03-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-03-28 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-03-28 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2016-03-28 11:37:18 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS. | | | CODE: FBC-5TH EDITION (2014). | | | | | | | | | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.002(33) FOR THE FLAT ROOF TO BE INSTALLED. | | | | | | 2- FROM FLAT ROOF PRODUCT APPROVAL REQUIRED BY ITEM #1 | | | ABOVE: | | | A) CLEARLY IDENTIFY WHICH APPROVED ASSEMBLY IS GOING TO | | | BE INSTALLED TO VERIFY COMPLIANCE WITH THE DESIGN | | | PRESSURES OF SEC. R301 OF FBC-RESIDENTIAL, 5TH EDITION | | | (2014). | | | | | | B) IF SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | | PRESSURES REQUIRED BY R301, THEN SIGNED AND SEALED RAS | | | 117 WILL BE REQUIRED. SEE LIMITATIONS ON PRODUCT | | | APPROVAL SUBMITTED. | | | | | | 3- NOTICE OF COMMENCEMENT REQUIRED. SEC. 713 FL. ST. | | | | | | 4- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW. SEC. 109.3 CITY AMENDMENTS. VALUATION WAS UPDATED | | | TO $7,060. THE PERMIT FEE BALANCE IS $248.13. | | | | | | 5- SPECIFY THE SHINGLES ROOF PITCH. SEC. R905.2.2 OF | | | FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-05-20 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-05-20 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-05-19 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2016-05-19 13:25:07 | RESUB ROUTED TO JGOMEZ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-03-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-03-28 |
Time |
15:03 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-03-25 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2016-03-25 13:17:39 | JGOMEZ |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |