| Plan Review Stops For Permit 16031054 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-10-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-10-18 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-10-18 |
Time |
09:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2016-04-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-04-21 |
Time |
18:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-04-21 |
Time |
18:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-10-17 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-10-17 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-10-17 |
Time |
10:07 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-03-29 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-03-29 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-03-29 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2016-03-29 12:59:25 | POOL BOX | | 2016-03-29 09:04:58 | INITIAL ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 | | | COMMENTS: | | | | | | 1. PROVIDE A GENERAL NOTE TO COMPLY WITH PART 4 AND 5 | | | OF NEC ARTICLE 680 | | | 2. PLEASE PROVIDE SPECIFICATION SHEET FOR ALL LIGHTING | | | FIXTURES BEING USED IN FOUNTAIN. FBC 107.3.5 | | | 3. SHOW THE BONDING ARRANGEMENTS TO COMPLY WITH NEC | | | 680.53 SPA AND FOUNTAIN. | | | 4. PROVIDE GFCI PROTECTION FOR THE LIGHTING CIRCUITS TO | | | FOUNTAIN, SHOW ON PANEL BOARD SCHEDULE. | | | 5. PROVIDE A NOTE TO COMPLY WITH NEC 680.41- EM SWITCH | | | SHUTOFF FOR SPA. | | | 6. FURTHER COMMENTS MAY FOLLOW UPON RESUBMITTAL. FEEL | | | FREE TO CONTACT ME AT THE NUMBER LISTED BELOW SHOULD | | | YOU HAVE ANY QUESTIONS OR CONCERNS. | | | | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2016-04-06 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-04-06 |
Time |
05:37 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-04-06 |
Time |
05:37 |
Sent To |
|
|
| Notes |
| 2016-04-06 05:37:59 | THERE IS NO GAS ASSOCIATED WITH THIS PERMIT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-10-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-10-18 |
Time |
09:48 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-10-03 |
Time |
09:37 |
Sent To |
|
|
| Notes |
| 2016-10-04 09:38:18 | RESUB ROUTED TO ESCHNEIDER VIA ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-04-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-04-21 |
Time |
18:27 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-03-23 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2016-03-24 09:19:24 | ROUTED TO ZONING |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2016-10-18 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-10-18 |
Time |
06:43 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-10-18 |
Time |
05:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-04-06 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-04-06 |
Time |
05:51 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-04-06 |
Time |
05:33 |
Sent To |
|
|
| Notes |
| 2016-04-06 05:37:09 | 1) SUBMIT 2 COPIES OF MANUFACTURER'S SPECIFICATIONS FOR | | | THE CHANNEL DRAIN, FBC 107.2.1. | | | 2) SHT. WF 103 - CROSS OFF ALL DETAILS THAT DO NOT | | | SPECIFICALLY PERTAIN TO THE FOUNTAIN. | | | 3) SUBMIT VERIFICATION THAT AN OP[ERATING PERMIT HAS | | | BEEN APPLIED FOR FROM THE PALM BEACH COUNTY HEALTH | | | DEPT. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2016-10-13 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2016-10-13 |
Time |
15:24 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2016-10-13 |
Time |
15:24 |
Sent To |
E |
|
| Notes |
| 2016-10-04 14:07:29 | ROUTED TO ERIC SCHNEIDER |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2016-03-28 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2016-03-28 |
Time |
19:55 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2016-03-28 |
Time |
19:55 |
Sent To |
E |
|
| Notes |
|
|