Plan Review Details - Permit 16031054
Plan Review Stops For Permit 16031054
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-10-18 Cont ID  
Sent By rmcdouga Date 2016-10-18 Time 09:48 Rev Time 0.00
Received By rmcdouga Date 2016-10-18 Time 09:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2016-04-21 Cont ID  
Sent By rmcdouga Date 2016-04-21 Time 18:26 Rev Time 0.00
Received By rmcdouga Date 2016-04-21 Time 18:26 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-10-17 Cont ID  
Sent By vperez Date 2016-10-17 Time 10:12 Rev Time 0.00
Received By vperez Date 2016-10-17 Time 10:07 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-03-29 Cont ID  
Sent By vperez Date 2016-03-29 Time 09:04 Rev Time 0.00
Received By vperez Date 2016-03-29 Time 08:52 Sent To  
Notes
2016-03-29 12:59:25POOL BOX
2016-03-29 09:04:58INITIAL ELECTRICAL PLAN REVIEW
  
 APPLICABLE CODES IN EFFECT:
 FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70- 2011
 COMMENTS:
  
 1. PROVIDE A GENERAL NOTE TO COMPLY WITH PART 4 AND 5
 OF NEC ARTICLE 680
 2. PLEASE PROVIDE SPECIFICATION SHEET FOR ALL LIGHTING
 FIXTURES BEING USED IN FOUNTAIN. FBC 107.3.5
 3. SHOW THE BONDING ARRANGEMENTS TO COMPLY WITH NEC
 680.53 SPA AND FOUNTAIN.
 4. PROVIDE GFCI PROTECTION FOR THE LIGHTING CIRCUITS TO
 FOUNTAIN, SHOW ON PANEL BOARD SCHEDULE.
 5. PROVIDE A NOTE TO COMPLY WITH NEC 680.41- EM SWITCH
 SHUTOFF FOR SPA.
 6. FURTHER COMMENTS MAY FOLLOW UPON RESUBMITTAL. FEEL
 FREE TO CONTACT ME AT THE NUMBER LISTED BELOW SHOULD
 YOU HAVE ANY QUESTIONS OR CONCERNS.
  
 VALENTINO PEREZ
 ELECTRICAL PLANS EXAMINER II
 561-805-6717
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2016-04-06 Cont ID  
Sent By tklarge Date 2016-04-06 Time 05:37 Rev Time 0.00
Received By tklarge Date 2016-04-06 Time 05:37 Sent To  
Notes
2016-04-06 05:37:59THERE IS NO GAS ASSOCIATED WITH THIS PERMIT.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-10-18 Cont ID  
Sent By rmcdouga Date 2016-10-18 Time 09:48 Rev Time 0.00
Received By rmcdouga Date 2016-10-03 Time 09:37 Sent To  
Notes
2016-10-04 09:38:18RESUB ROUTED TO ESCHNEIDER VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-04-21 Cont ID  
Sent By rmcdouga Date 2016-04-21 Time 18:27 Rev Time 0.00
Received By rmcdouga Date 2016-03-23 Time 09:19 Sent To  
Notes
2016-03-24 09:19:24ROUTED TO ZONING

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-10-18 Cont ID  
Sent By tklarge Date 2016-10-18 Time 06:43 Rev Time 0.00
Received By tklarge Date 2016-10-18 Time 05:56 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-04-06 Cont ID  
Sent By tklarge Date 2016-04-06 Time 05:51 Rev Time 0.00
Received By tklarge Date 2016-04-06 Time 05:33 Sent To  
Notes
2016-04-06 05:37:091) SUBMIT 2 COPIES OF MANUFACTURER'S SPECIFICATIONS FOR
 THE CHANNEL DRAIN, FBC 107.2.1.
 2) SHT. WF 103 - CROSS OFF ALL DETAILS THAT DO NOT
 SPECIFICALLY PERTAIN TO THE FOUNTAIN.
 3) SUBMIT VERIFICATION THAT AN OP[ERATING PERMIT HAS
 BEEN APPLIED FOR FROM THE PALM BEACH COUNTY HEALTH
 DEPT.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2016-10-13 Cont ID  
Sent By eschneid Date 2016-10-13 Time 15:24 Rev Time 0.25
Received By eschneid Date 2016-10-13 Time 15:24 Sent To E
Notes
2016-10-04 14:07:29ROUTED TO ERIC SCHNEIDER

Review Stop Z ZONING
Rev No 1 Status P Date 2016-03-28 Cont ID  
Sent By eschneid Date 2016-03-28 Time 19:55 Rev Time 0.25
Received By eschneid Date 2016-03-28 Time 19:55 Sent To E
Notes
***NONE***