| 2016-03-24 07:23:49 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 16030973 |
| | ADD: 2709 EMBASSY DR. |
| | CONT: LEO ROOFING |
| | TEL: 561-935-4979 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: THURS. MARCH 24/ 2016 |
| | ACTION: DENIED |
| | |
| | 1) ROOFING FORM 100 THE EXPOSURE IS FILED OUT AS A B |
| | EXPOSURE, NOTE THE EXPOSURE IS A C EXPOSURE AND MINIMUM |
| | ROOF HEIGHTS ARE TAKEN AT 15 FEET.2014 FBC-B 1603.1.4 |
| | WIND DESIGN DATA. PLEASE CORRECT. |
| | |
| | 2) SUBMITTED ROOFING TILE PRODUCT APPROVAL FL 7804-R8. |
| | 2A) PAGE2-3 OF 7 THE TYPE OF ROOF TILE NOT IDENTIFIED. |
| | 2B) NONE OF THE TABLES ON PAGES 4-6 WERE FILED OUT FOR |
| | ATTACHMENT. |
| | 107.2.1.3 ADDITIONAL INFORMATION REQUIRED. FBC-B |
| | 1609.5.3 RIGID TILE. WIND LOADS ON RIGID TILE ROOF |
| | COVERINGS SHALL BE DETERMINED IN ACCORDANCE WITH THE |
| | FOLLOWING EQUATION: |
| | |
| | 3) ROOFING UNDERLAYMENT FL 5259-R23 LIMITATION 5.5 |
| | ALLOWABLE ROOF COVERS TABLE 1 THE TYPE OF UNDERLAYMENT |
| | NOT IDENTIFIED. 107.2.1.3 ADDITIONAL INFORMATION |
| | REQUIRED TO DETERMINE CODE COMPLIANCE. |
| | |
| | 4A) THIS RESIDENCE WAS BUILT IN 1990. THE IMPROVEMENT |
| | VALUE FOR THE RESIDENCE IS $338,865.00 DOLLARS, PLEASE |
| | PROVIDE COMPLIANCE WITH THE 2014 EXISITNG BUILDING CODE |
| | 708.8 |
| | WHEN A ROOF COVERING ON AN EXISTING SITE-BUILT SINGLE |
| | FAMILY RESIDENTIAL STRUCTURE IS REMOVED AND REPLACED ON |
| | A BUILDING THAT IS LOCATED IN THE WIND-BORNE DEBRIS |
| | REGION AS DEFINED IN THE FLORIDA BUILDING CODE, |
| | BUILDING AND THAT HAS AN INSURED VALUE OF $300,000 OR |
| | MORE OR, IF THE BUILDING IS UNINSURED OR FOR WHICH |
| | DOCUMENTATION OF INSURED VALUE IS NOT PRESENTED, HAS A |
| | JUST VALUATION FOR THE STRUCTURE FOR PURPOSES OF AD |
| | VALOREM TAXATION OF $300,000 OR MORE: |
| | |
| | (A) ROOF TO WALL CONNECTIONS SHALL BE IMPROVED AS |
| | REQUIRED BY SECTION 708.8.1. |
| | |
| | (B) MANDATED RETROFITS OF THE ROOF-TO-WALL CONNECTION |
| | SHALL NOT BE REQUIRED BEYOND A 15-PERCENT INCREASE IN |
| | THE COST OF REROOFING. |
| | |
| | |
| | |
| | 4B) 2014 FBC-EXIST. BLDG. CODE 708.8.1 ROOF-TO-WALL |
| | CONNECTIONS FOR SITE-BUILT SINGLE FAMILY RESIDENTIAL |
| | STRUCTURES. |
| | WHERE REQUIRED BY SECTION 708.8, THE INTERSECTION OF |
| | ROOF FRAMING WITH THE WALL BELOW SHALL PROVIDE |
| | SUFFICIENT RESISTANCE TO MEET THE UPLIFT LOADS |
| | SPECIFIED IN TABLE 708.8.1, EITHER BECAUSE OF EXISTING |
| | CONDITIONS OR THROUGH RETROFIT MEASURES. AS AN |
| | ALTERNATIVE TO AN ENGINEERED DESIGN, THE PRESCRIPTIVE |
| | RETROFIT SOLUTIONS PROVIDED IN SECTIONS 708.8.1.1 |
| | THROUGH 708.8.1.7 SHALL BE ACCEPTED AS MEETING THE |
| | MANDATED ROOF-TO-WALL RETROFIT REQUIREMENTS. |
| | |
| | EXCEPTIONS: |
| | |
| | 1. WHERE IT CAN BE DEMONSTRATED (BY CODE ADOPTION DATE |
| | DOCUMENTATION AND PERMIT ISSUANCE DATE) THAT |
| | ROOF-TO-WALL CONNECTIONS AND/OR ROOF-TO FOUNDATION |
| | CONTINUOUS LOAD PATH REQUIREMENTS WERE REQUIRED AT THE |
| | TIME OF ORIGINAL CONSTRUCTION. |
| | |
| | 2. ROOF-TO-WALL CONNECTIONS SHALL NOT BE REQUIRED |
| | UNLESS EVALUATION AND INSTALLATION OF CONNECTIONS AT |
| | GABLE ENDS OR ALL CORNERS CAN BE COMPLETED FOR 15 |
| | PERCENT OF THE COST OF ROOF REPLACEMENT. |
| | |