Plan Review Details - Permit 16030881
| Plan Review Stops For Permit 16030881 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2016-05-11 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-05-11 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-05-11 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2016-05-11 09:19:08 | 3RD ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 NEC | | | COMMENTS: | | | | | | 1. PROVISO TO PROVIDE AS-BUILT TO REFLECT UPDATED | | | GOVERNING CODES AS STATED ABOVE AND ITEMS LISTED BELOW. | | | 2. SHOW GROUNDING ELECTRODE CONDUCTOR SIZE AT THE | | | SERVICE PER SERVICE CHANGE. #2 GEC PER NEC 250.66 | | | TABLE. | | | 3. PROVIDE AN INTERSYSTEM BONDING CONNECTION. NEC | | | 250.94 | | | 4. LABEL MAINS PER NEC 230.2 FOR ALL 100A BREAKERS | | | SHOWN AT THE METER GANG BOX. EXAMPLE MAIN #1 OF 4, 2 OF | | | 4, ETC. | | | 5. PER FBC RES 315- PROVIDE SD/CO MONOXIDE DETECTORS ON | | | THE EXTERIOR OF ROOMS. | | | 6. PLEASE FEEL FREE TO CONTACT ME SHOULD YOU HAVE ANY | | | QUESTIONS REGARDING THIS PROJECT. | | | | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2016-04-04 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-04-04 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-04-04 |
Time |
14:04 |
Sent To |
|
|
| Notes |
| 2016-04-04 18:02:54 | ELECTRICAL REVIEW COMMENTS | | | REVIEWED FOR COMPLIANCE WITH: | | | 2010 FBC & 2008 NEC | | | | | | CORRECTIONS REQUIRED: | | | 1. THIS IS A LEVEL 2 ALTERATION OF AN R2 OCCUPANCY. | | | 2. HOW DID THE ELECTRICAL GO FROM WHAT WAS PRESENTED ON | | | THE INITIAL PLAN APPROVED ON 4/9/15 TO THE PLAN | | | SUBMITTED ON 3/21/16. THE INITIAL PLANS SHOW THE | | | ELECTRIC PANEL INSIDE THE UNIT AND THE NEW ONE HAS THE | | | PANEL IN THE ELECTRIC ROOM. | | | 3. DO ALL OF THE UNITS HAVE GAS OR ELECTRIC COOKING | | | APPLIANCES. IF ELECTRIC, THE RESPECTIVE LOAD SHALL | | | APPEAR ON THE LOAD CALCS. | | | 4. DOES EACH UNIT HAVE AN INDEPENDENT WATER HEATER OR | | | IS THERE A COMMON UNIT. THE SAME ARISES, ARE THEY GAS | | | OR ELECTRIC. IF ELECTRIC THE LOAD SHALL APPEAR ON THE | | | LOAD CALCS. | | | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | | RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER | | | (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER | | | WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD | | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID | | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | | GREATLY APPRECIATED. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU, | | | MIKE ALBARRAN | | | ELECTRICAL PLANS EXAMINER | | | PH: 561-805-6746 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-03-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-03-22 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-03-22 |
Time |
16:07 |
Sent To |
I |
|
| Notes |
| 2016-03-22 17:13:12 | TRYING TO GET THE SCOPE OF WORK I LOOKED AT THE | | | VERBIAGE ON THE PERMIT. IT DIDN'T MATCH THE DRAWING | | | WHICH PROMPTED ME TO GO INTO FILENET TO DIG IN FURTHER. | | | IN DOING SO I NOTICED THAT THE INITIAL PERMIT | | | APPLICATION DID NOT CONCUR WITH THE APPROVED PLANS, BUT | | | FURTHER THE DRAWINGS WERE SUFFICIENTLY DIFFERENT THAT I | | | CONTACTED THE ENGINEER OF RECORD TO DISCUSS THE MATTER. | | | WE DISCUSSED THE THIS AND MR. ROJAS WILL SUBMIT | | | CORRECTED DRAWINGS FOR REVIEW. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-05-11 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-05-11 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-05-11 |
Time |
09:19 |
Sent To |
|
|
| Notes |
| 2016-05-10 14:29:56 | RESUB OF REVISION ROUTED TO ELEC <5K |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-04-04 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-04-04 |
Time |
18:03 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-04-01 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2016-04-04 18:05:38 | I SPOKE W/SAM FISH AND EXPLAINED THE REQUIRED | | | CORRECTIONS TO HIM. I ADVISED HIM THAT THIS WILL BE IN | | | THE DENIED BIN "B" WAITING FOR A RESUBMITTAL. MA | | | | | 2016-04-01 16:00:45 | RESUB ROUTED TO MALBARRAN |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-03-22 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-03-22 |
Time |
17:13 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-03-21 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2016-03-22 17:15:15 | 3/22/16 FAILED ELECTRICAL REVIEW AS NOTED. ENGINEER | | | NOTIFIED VIA PHONE CONVERSATION. SENT FILE TO SMALL | | | DENIED BIN "B'". MA | | 2016-03-21 17:29:24 | REVISION SHOWS FOUR METERS IN AN ELECTRIC ROOM. NO | | | LONGER A TWO FAMILY DWELLING. GAVE TO M. ALBERRAN FOR | | | REVIEW. RM | | 2016-03-21 15:24:10 | REVISION ROUTED TO RMCDOUGAL |
|
|
|
Account Summary | Usage Policy | Privacy Policy