| Plan Review Stops For Permit 16030772 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2016-03-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-03-24 |
Time |
16:29 |
Rev Time |
|
| Received By |
jwitmer |
Date |
2016-03-24 |
Time |
2:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2016-03-17 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2016-03-17 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2016-03-17 |
Time |
12:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2016-03-24 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2016-03-24 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2016-03-24 |
Time |
10:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-04-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-04-11 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-04-05 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2016-04-05 14:54:55 | ROUTED TO TKLARGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-03-26 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-03-26 |
Time |
05:18 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-03-26 |
Time |
05:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2016-03-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-03-24 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-03-24 |
Time |
16:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2016-04-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-04-11 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-04-11 |
Time |
10:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-03-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-03-21 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-03-21 |
Time |
11:46 |
Sent To |
|
|
| Notes |
| 2016-03-21 12:13:57 | 1ST REVIEW: FBC 2014 MECHANICAL | | | PERMIT #16030772 | | | 3/21/16 | | | | | | | | | 1) SHEET M1: ALL CODE REQUIRED DUCT SMOKE DETECTORS | | | SHALL BE INSTALLED IN THE RETURN AIR SYSTEMS, PLEASE | | | REVISE NOTE #1 AND INDICATE IF ALL THE SYSTEMS WILL BE | | | LINKED TOGETHER FOR FAN SHUT IF ANY SINGLE DETECTOR | | | ACTIVATES. | | | 2) M1: THE 10" FLEX DUCTS SUPPLYING 350 CFMS FOR AHU'S | | | #1, 2, & 6 NEED TO INCREASE TO 12". | | | 3) M1: THE EXHAUST FROM EF-1 SHALL DISCHARGE TO THE | | | OUTDOORS IN ACCORDANCE WITH SECTION 501.3 FBC-14 | | | MECHANICAL. | | | 4) M2: THERE IS A DETAIL FOR TIE DOWN OF A AC CONDENSER | | | UNIT TO AN EXISTING ROOF STAND, HOWEVER THERE ARE NO | | | NEW CONDENSERS SHOWN ON THE PLANS: PLEASE CLARIFY | | | 5) PROVIDE NOTE AND DETAILS INDICATING HOW ACCESS FOR | | | SERVICE AND REPLACEMENT OF THE ABOVE CEILING AHU'S AND | | | MOTORIZED DAMPERS WILL BE PROVIDED. | | | 6) M2: PROVIDE HANGING, REINFORCEMENT, AND CONNECTION | | | DETAILS FOR THE RIGID DUCTS IN ACCORDANCE WITH TABLE | | | C403.2.7.2 FBC-14 ENERGY CONSERVATION. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2016-04-09 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-04-09 |
Time |
03:56 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-04-09 |
Time |
03:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-03-26 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-03-26 |
Time |
05:18 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-03-26 |
Time |
05:08 |
Sent To |
|
|
| Notes |
| 2016-03-26 05:18:14 | 1) PROVIDE SANITARY & WATER RISER DIAGRAMS FOR ALL | | | CHANGES TO THE PLUMBING SYSTEM. CLARIFY.FBC | | | 107.3.5.1.3. | | | 2) THE WATER SUPPLY TO THE COFFEE MACHINES SHALL BE | | | PROTECTED AGAINST BACKFLOW PER 2014 FBC-PLUMBING | | | SEC.608.16.10. | | | 3) HOT WATER SHALL BE SUPPLIED TO THE BREAKROOM SINK | | | PER 2014 FBC-PLUMBING SEC.607.1. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2016-03-17 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2016-03-17 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2016-03-17 |
Time |
12:13 |
Sent To |
|
|
| Notes |
| 2016-03-17 12:16:10 | ZONING APPROVAL WITH PERMIT # 16030424 AS BOTH SUITES | | | WERE INCLUDED WITH THE INITIAL APPLICATION. RL |
|
|