Plan Review Details - Permit 16030671
Plan Review Stops For Permit 16030671
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-12-15 Cont ID  
Sent By cthroop Date 2016-12-15 Time 08:32 Rev Time 0.00
Received By cthroop Date 2016-12-15 Time 08:32 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-12-02 Cont ID  
Sent By cthroop Date 2016-12-02 Time 15:17 Rev Time 0.00
Received By cthroop Date 2016-12-02 Time 15:17 Sent To E
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-03-25 Cont ID  
Sent By cthroop Date 2016-03-25 Time 13:37 Rev Time 0.00
Received By cthroop Date 2016-03-25 Time 13:37 Sent To  
Notes
2016-03-25 15:07:141ST REVIEW: FBC 2014 5TH ED
 CHRISTOPHER S. THROOP, C.B.O.
 BLDG. PLANS EXAMINER ? PX3169
 (561) 805-6718
 [email protected]
  
 GENERAL NOTES:
 PLANS INCLUDE PERGOLA, GARAGE & DECK.
 1. VALUE APPEARS LOW FOR SCOPE OF WORK. PROVIDE COPY OF
 ESTIMATE OR MATERIAL RECEIPTS.
 2. PROVIDE SITE PLAN TO VERIFY SETBACKS. (SEE ZONING
 COMMENTS).
 3. PROVIDE WIND SPEED CALCULATIONS FOR PERGOLA, GARAGE
 AND DECK.
 4. STATE GOVERNING CODES ON PLANS. (FBC 2014 5TH ED.,
 NEC 2011,ETC.).
 DECK NOTES:
 5. PROVIDE DETAIL FOR POST BASE FOUNDATION. PG. A2.0
 6. SPECIFY FLASHING TYPE. PG. A2.0
 7. SPECIFY POST CAP ATTACHMENT FASTENER PER DETAIL 3,
 PG. A2.1
 8. STAIR RISER HEIGHT NOT TO EXCEED 3/8" DEVIATION PER
 DETAIL 6, PG. A2.1.
 9. PROVIDE SPACING FOR 1/2" DIAMETER THRU BOLTS @
 LEDGER BOARD PER DETAIL 5, PG. A2.I.
 10.SPECIFY WOOD SPECIES AND GRADE FOR DECK JOISTS,
 LEDGERS AND BEAMS TO VERIFY ALLOWBLE SPANS. PG. A2.1.
 11. OVERALL DECK WIDTH OF 19FT.-0" EXCEEDS LUMBER
 LENGTH IN MATERIAL SCHEDULE. PROVIDE DETAIL FOR
 SPLICING AND BEARING OF DECK BEAMS. PG. A2.0.
 PERGOLA NOTES: INSUFFECIENT INFORMATION TO COMPLETE
 REVIEW. ADDITIONAL REVIEW NOTES POSSIBLE.
 12. PROVIDE SCHEDULE OF MATERIALS. PG. A2.2.
 13. PROVIDE POST BASE DETAIL. PG. A2.2.
 14. PROVIDE CONNECTOR SCHEDULE AND FASTENER SCHEDULE
 FOR ALL CONNECTIONS. PG. A2.2.
 GARAGE NOTES:
 15. PROVIDE STRUCTURAL DRAWINGS FOR FOUNDATION, CMU
 WALLS AND BEAMS. PG. A1.4.
 16. PROVIDE DETAIL FOR BEAM TO TRUSS CONNECTION. PG
 A1.4.
 17. PROVIDE ROOF SHEATHING FASTENER SCHEDULE BASED ON
 WIND SPPED CALC'S.
 18. PROVIDE PRODUCT APPROVALS FOR EXTERIOR DOOR,
 OVERHEAD DOOR AND ROOF SYSTEM PRODUCTS.
 19. ROOFING PERMIT REQUIRED.
  
 FBC 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE
 TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY
 LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST
 PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS
 SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
 FAILURE TO PROVIDE DOCUMENTATION OF ESTIMATED COSTS MAY
 DELAY THE APPLICATION PROCESS.
  
 FBC 107.3.5.3 ? PROVIDE A SITE PLAN TO DEMONSTRATE
 SETBACKS AND BUILDING SEPARATION.
  
 FBC 107.3.5.3 - PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-R301.2.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES
 SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE
 TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE
 FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE
 DESIGN. (SEE ALSO SECTION 107.3.5).
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING AND DOOR SUBMITTALS.
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2016-12-14 Cont ID  
Sent By mvaldes Date 2016-12-14 Time 18:36 Rev Time 0.00
Received By mvaldes Date 2016-12-14 Time 18:19 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-12-05 Cont ID  
Sent By mvaldes Date 2016-12-05 Time 10:31 Rev Time 0.00
Received By mvaldes Date 2016-12-05 Time 10:20 Sent To  
Notes
2016-12-05 10:33:012ND REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 561-805-6713
 [email protected]
  
 PASSED WITH THE FOLLOWING PROVISO
  
 1] GARAGE & TERRACE RECEPTACLE OUTLETS SHALL BE GFCI
 PROTECTED PER NEC 210.8(A)

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-03-23 Cont ID  
Sent By mvaldes Date 2016-03-23 Time 13:08 Rev Time 0.00
Received By mvaldes Date 2016-03-23 Time 13:08 Sent To B
Notes
2016-03-23 13:17:16REVIEW 2014 5TH FBC ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 516-805-6713
 [email protected]
  
  
 -PROVIDE GFCI PROTECTION FOR GARAGE OUTLETS INCLUDING
 GARAGE DOOR. NEC 210.8A
  
 -CLARIFY IF ANY ELECTRICAL WORK IN THE DECK AREA NEW
 PERBOLA IN THE PATIO ? WBA 107

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-12-15 Cont ID  
Sent By cthroop Date 2016-12-15 Time 08:32 Rev Time 0.00
Received By cthroop Date 2016-12-07 Time 11:12 Sent To  
Notes
2016-12-08 11:12:23RESUB ROUTED TO NJWIRA VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-12-05 Cont ID  
Sent By mvaldes Date 2016-12-05 Time 10:33 Rev Time 0.00
Received By mvaldes Date 2016-11-23 Time 16:41 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-03-25 Cont ID  
Sent By cthroop Date 2016-03-25 Time 15:07 Rev Time 0.00
Received By cthroop Date 2016-03-15 Time 09:58 Sent To  
Notes
2016-03-23 14:06:50MISC 2
2016-03-16 09:58:17ROUTED TO ZONING

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2016-03-25 Cont ID  
Sent By cthroop Date 2016-03-25 Time 13:23 Rev Time 0.00
Received By cthroop Date 2016-03-25 Time 13:23 Sent To  
Notes
2016-03-25 13:29:53IMPACT FEES NOT REQUIRED FOR GARAGE.

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2016-12-15 Cont ID  
Sent By cthroop Date 2016-12-15 Time 08:32 Rev Time 0.00
Received By cthroop Date 2016-12-15 Time 08:32 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2016-12-02 Cont ID  
Sent By cthroop Date 2016-12-02 Time 15:15 Rev Time 0.00
Received By cthroop Date 2016-12-02 Time 15:15 Sent To  
Notes
2016-12-02 15:17:46BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER ? PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW
 RESULTS: DENIED
  
 1. PROVIDE FASTENER SCHEDULE FOR ROOF SHEATHING.
 2. PROVIDE PRODUCT APPROVALS FOR ROOF SYSTEM
 COMPONENTS.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY
 FAC RULE 9N-3 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD. SPECIFICALLY, PROVIDE ROOFING
 SUBMITTALS.
  
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2016-03-25 Cont ID  
Sent By cthroop Date 2016-03-25 Time 13:32 Rev Time 0.00
Received By cthroop Date 2016-03-25 Time 13:32 Sent To  
Notes
2016-03-25 13:37:101ST REVIEW: FBC 2014 5TH ED
 CHRISTOPHER S. THROOP, C.B.O.
 BLDG. PLANS EXAMINER ? PX3169
 (561) 805-6718
 [email protected]
  
 1. PROVIDE WIND SPEED CALCULATIONS.
 2. PROVIDE FASTENER SCHEDULE BASED ON WIND SPEED
 CALC'S.
 3. PROVIDE PRODUCT APPROVALS FOR ROOF SYSTEM.
  
 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED,
 VASD, AS DETERMINED IN ACCORDANCE WITH SECTION
 1609.3.1.
 2. RISK CATEGORY.
 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED.
 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL
 RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/
 M2).
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES
 SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE
 TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE
 FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE
 DESIGN. (SEE ALSO SECTION 107.3.5).
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS.
  

Review Stop Z ZONING
Rev No 3 Status P Date 2016-12-08 Cont ID  
Sent By njwira Date 2016-12-08 Time 16:15 Rev Time 0.00
Received By njwira Date 2016-12-08 Time 15:26 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2016-12-01 Cont ID  
Sent By mvaldes Date 2016-12-05 Time 10:33 Rev Time 0.00
Received By njwira Date 2016-11-28 Time 14:28 Sent To B
Notes
2016-12-01 16:03:5612/1/16- FAILED
  
 SF-7
  
 TREE ALTERATION PERMIT REQUIRED IF YOU ARE MOVING ANY
 TREES
 75% IMPERVIOUS SURFACE IN THE FRONT SETBACK MET
 5FT.1IN. SIDE SETBACK MEETS 5FT. REQUIREMENT
 MEETS FRONT SETBACK REQUIREMENT
 9FT. 9IN. BUILDING HEIGHT MEETS 30FT. LIMIT
  
 PLEASE CONTACT
 NATHAN WIRA
 [email protected]
 (561)822-1442
  

Review Stop Z ZONING
Rev No 1 Status F Date 2016-03-22 Cont ID  
Sent By ajones Date 2016-03-22 Time 16:43 Rev Time 0.00
Received By ajones Date 2016-03-22 Time 16:43 Sent To E
Notes
2016-03-22 16:46:223/22/16- FAILED. THE GARAGE NEEDS TO BE SHOWN ON THE
 SURVEY WITH PROPOSED FRONT AND SIDE SETBACK SHOWN.
 ANGELLA VANN, AICP
 [email protected]
 561-822-1441


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved