Plan Review Details - Permit 16030488
Plan Review Stops For Permit 16030488
Review Stop AIPP ART IN PUBLIC PLACES
Rev No 1 Status P Date 2016-06-23 Cont ID  
Sent By rbrown Date 2016-06-23 Time 16:43 Rev Time 0.00
Received By rbrown Date 2016-06-23 Time 16:43 Sent To  
Notes
2016-06-23 16:47:05PALM BEACH ATLANTIC UNIVERSITY SUBMITTED A COPY OF
 THEIR 501(C)(3) CERTIFICATE OF EXEMPTION TO SYBILLE
 WELTER. THEY ARE THEREFORE EXEMPT FROM CONTRIBUTION TO
 THE ART IN PUBLIC PLACES FUND.
  
 TELEPHONE: (561) 805 6652 ROBERT BROWN
 E-MAIL: [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-04-20 Cont ID  
Sent By jwitmer Date 2016-04-20 Time   Rev Time 0.00
Received By jwitmer Date 2016-04-20 Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-04-11 Cont ID  
Sent By jwitmer Date 2016-04-11 Time 12:46 Rev Time 0.00
Received By jwitmer Date 2016-04-06 Time 13:01 Sent To  
Notes
2016-04-11 12:46:02BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16030488
 ADD: 900 S. OLIVE AVE./ 10 DORMS 201,202,307, 308, 309,
 407, 408, 409, 505 & 506.
 CONT: ROBLING ARCHITECTURE CONSTRUCTION, INC.
 TEL: 561-649-6705
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: MON. APRIL 11/ 2016
 ACTION: DENIED
  
 1A) 2ND REQUEST. SHEET A-2 SHOWS A NEW EXTERIOR INSWING
 DOOR. THERE WERE NO PRODUCT APPROVALS IN THIS SUBMITTAL
 PACKAGE FOR A INSWING DOOR. . FLORIDA DEPARTMENT OF
 COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31)
 SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT
 WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS. INSWING.
 NOTE: SHEET A-4 DOES HAVE A OUTSWING DOOR. CHEM-PRUF
 DOOR ?OUTSWING DOOR TECHNICAL SHEETS WAS SUBMITTED BUT
 THERE IS NO COVERSHEET SHOWING IT TO BE A MIAMI-DADE
 NOA OR FLORIDA APPROVAL AND UNDER WHICH CODE THE
 APPROVAL WAS GIVEN.
  
 1B) 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA
 RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN WRITING BY
 THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
  
 1C) COMPLIED / WIND DESIGN CRITERIA.
  
 1D) COMPLIED FLOOR SOUND INSULATION FOR TILE. ASTM E
 492/ ASTM E 90 & ASTM 84 OR UL 723
  
 2) COMPLIED FLOOR SOUND INSULATION FOR TILE. ASTM E
 492/ ASTM E 90 & ASTM 84 OR UL 723
  
 3A-B) COMPLIED. SHEET A-4 A NEW OUTSWING EXTERIOR DOOR.
  
 3C) COMPLIED.
  
  
 4-5) COMPLIED
  
 6A) 2ND REQUEST. THE RESPONSE INDICATES COMPLIANCE WITH
 THE ADA OF 1990 SECTION 202.3: EXCEPTION3.
 PLEASE SEE THE SECTIONS LISTED BELOW ARE UNDER THE
 FLORIDA ACCESSIBILITY CODE ENACTED BECAUSE OF
 REMODELING, ALTERATIONS TO THE BUILDING. THE ONLY
 RELIEF TO THIS PORTION OF THE CODE LISTED BELOW AND ALL
 SECTIONS IS THE 20% DISPROPORTIONATE COST. THE ACCESS.
 CODE REQUIRES 20% OF THE CONTRACT VALUE OR AN
 ADDITIONAL $40,000.00 DOLLARS BE SPENT IN ACCESSIBLE
 UPGRADES AS LISTED BELOW. IF FULL COMPLIANCE CANNOT BE
 ACCOMPLISHED WITH THE $40,000.00 DOLLARS THEN AN
 ITEMIZED LIST OF HOW THE FUNDS ARE TO BE SPENT IN THE
 FOLLOWING ORDER, PLEASE HAVE THE ITEMIZED LIST ON
 EITHER THE ARCHITECTS OR CONTRACTORS LETTERHEAD.
  
 202.4.2 ACCESSIBLE FEATURES IN THE EVENT OF
 DISPROPORTIONALITY.
 WHEN THE COST OF ALTERATIONS NECESSARY TO MAKE THE PATH
 OF TRAVEL TO THE ALTERED AREA FULLY ACCESSIBLE IS
 DISPROPORTIONATE TO THE COST OF THE OVERALL ALTERATION,
 THE PATH OF TRAVEL SHALL BE MADE ACCESSIBLE TO THE
 EXTENT THAT IT CAN BE MADE ACCESSIBLE WITHOUT INCURRING
 DISPROPORTIONATE COSTS. IN CHOOSING WHICH ACCESSIBLE
 ELEMENTS TO PROVIDE, PRIORITY SHOULD BE GIVEN TO THOSE
 ELEMENTS THAT WILL PROVIDE THE GREATEST ACCESS, IN THE
 FOLLOWING ORDER: (I) AN ACCESSIBLE ENTRANCE; (II) AN
 ACCESSIBLE ROUTE TO THE ALTERED AREA; (III) AT LEAST
 ONE ACCESSIBLE RESTROOM FOR EACH SEX OR A SINGLE UNISEX
 RESTROOM; (IV) ACCESSIBLE TELEPHONES; (V) ACCESSIBLE
 DRINKING FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL
 ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND
 ALARMS.
  
  
 COMMENTS FROM THE 1ST REVIEW.
 PLEASE NOTE THE PLANS AND PERMIT APPLICATION INDICATE
 THE RENOVATION OF 10 DORMITORY ROOMS. PLEASE REVIEW
 SECTION 224.7 OF THE 2014 FBC-ACCESSIBILITY CODE. 224.7
 HOUSING AT A PLACE OF EDUCATION. HOUSING AT A PLACE OF
 EDUCATION SHALL COMPLY WITH THE REQUIREMENTS FOR
 TRANSIENT LODGING GUEST ROOMS IN SECTIONS 224 AND 806,
 SUBJECT TO THE FOLLOWING EXCEPTIONS. THE TERM SLEEPING
 ROOM IS INTENDED TO BE USED INTERCHANGEABLY WITH THE
 TERM GUEST ROOM AS IT IS USED IN THE TRANSIENT LODGING
 STANDARDS.
  
 FBC - ACCESS. CODE 224.1.1 ALTERATIONS.
 WHERE GUEST ROOMS ARE ALTERED OR ADDED, THE
 REQUIREMENTS OF 224 SHALL APPLY ONLY TO THE GUEST ROOMS
 BEING ALTERED OR ADDED UNTIL THE NUMBER OF GUEST ROOMS
 COMPLIES WITH THE MINIMUM NUMBER REQUIRED FOR NEW
 CONSTRUCTION.
 ADVISORY 224.1.1 ALTERATIONS.
 IN ALTERATIONS AND ADDITIONS, THE MINIMUM REQUIRED
 NUMBER OF ACCESSIBLE GUEST ROOMS IS BASED ON THE TOTAL
 NUMBER OF GUEST ROOMS ALTERED OR ADDED INSTEAD OF THE
 TOTAL NUMBER OF GUEST ROOMS PROVIDED IN A FACILITY.
 TYPICALLY, EACH ALTERATION OF A FACILITY IS LIMITED TO
 A PARTICULAR PORTION OF THE FACILITY. WHEN ACCESSIBLE
 GUEST ROOMS ARE ADDED AS A RESULT OF SUBSEQUENT
 ALTERATIONS, COMPLIANCE WITH 224.5 (DISPERSION) IS MORE
 LIKELY TO BE ACHIEVED IF ALL OF THE ACCESSIBLE GUEST
 ROOMS ARE NOT PROVIDED IN THE SAME AREA OF THE
 FACILITY.
  
 6B) FBC-ACCESS. CODE 224.4 GUEST ROOMS WITH
 COMMUNICATION FEATURES.
 IN TRANSIENT LODGING FACILITIES, GUEST ROOMS WITH
 COMMUNICATION FEATURES COMPLYING WITH 806.3 SHALL BE
 PROVIDED IN ACCORDANCE WITH TABLE 224.4.
  
 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-03-17 Cont ID  
Sent By jwitmer Date 2016-03-17 Time 15:25 Rev Time 0.00
Received By jwitmer Date 2016-03-17 Time 13:02 Sent To  
Notes
2016-03-17 15:25:05BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16030488
 ADD: 900 S. OLIVE AVE./ 10 DORMS 201,202,307, 308, 309,
 407, 408, 409, 505 & 506.
 CONT: ROBLING ARCHITECTURE CONSTRUCTION, INC.
 TEL: 561-649-6705
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. MARCH 17/ 2016
 ACTION: DENIED
  
 1A) SHEET A-2 SHOWS A NEW EXTERIOR INSWING DOOR. THERE
 WERE NO PRODUCT APPROVALS IN THIS SUBMITTAL PACKAGE.
 FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV.
 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION
 SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS. INSWING.
  
 1B) 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA
 RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN WRITING BY
 THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
  
 1C) PLEASE PROVIDE THE WIND DESIGN CRITERIA FOR THE NEW
 EXTERIOR DOOR. THE COVERSHEET IS LISTING A 170 MPH VULT
 BUT IT IS ALSO LISTING A BUILDING RISK CATEGORY III
 WHICH WILL PUT THIS BUILDING INTO A 180 MPH VULT WIND
 ZONE. SEE 2014 FBC-B TABLE 1604.5 & FIGURE 1609B.
  
 2014 FBC-B 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
  
 1C)1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND
 GUST), MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND
 SPEED, VASD, AS DETERMINED IN ACCORDANCE WITH SECTION
 1609.3.1.
  
 1C) 2. RISK CATEGORY.
  
 1C) 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7(2)
 ADJUSTMENT FACTORS FOR HEIGHT & EXPOSURE. PROVIDE THE
 MEAN ROOF HEIGHT FOR THE BUILDING.
  
 1C) 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
  
 1C) 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL
 RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/
 M2).
  
 1D) THE PLANS INDICATE THE INSTALLATION OF NEW
 PORCELAIN TILE ON THE FLOORS, FOR TILE, STONE, MARBLE
 AND WOOD FLOORING ALL NEED TO HAVE HAD THE SOUND
 UNDERLAYMENT TESTED TO THE FOLLOWING STANDARDS AND MEET
 THE QUALIFICATIONS LISTED UNDER EACH OF THE STANDARDS:
 PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH:
 1D)(A) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 1D)(B) FBC-B 2014 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 1D)(C) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 2) SHEET A-3 ALSO INDICATES THE USE OF NEW PORCELAIN
 TILE ON THE FLOORS SHOW COMPLIANCE WITH COMMENT 1D.
  
 3A) SHEET A-4 RENOVATION NOTES INDICATE A NEW OUTSWING
 EXTERIOR DOOR. THERE WERE NO PRODUCT APPROVALS IN THIS
 SUBMITTAL PACKAGE. FLORIDA DEPARTMENT OF COMMUNITY
 AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF
 PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE
 PRODUCT APPROVALS:
 (31)(A) EXTERIOR DOORS. OUTSWING.
  
 3B) 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA
 RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN WRITING BY
 THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
  
 3C) SHEETS A4 THE DEMOLITION AND RENOVATION KEY NOTES
 HAVE BEEN COPIED FROM 201 & 202 WITH THE HEADING FOR
 ROOMS 201 & 202 ARE THESE NOTE CORRECT TO THE SCOPE OF
 WORK FOR THIS UNIT. IN THE UPPER LEFT CORNER OF THE
 PLANS THERE IS A CONTRADICTORY NOTE. 107.2.1.3.
 ADDITIONAL INFORMATION IS REQUIRED.
  
 4) SHEET A-4 THE DEMOLITION NOTE INDICATES THE REMOVAL
 OF THE KITCHEN BUT THERE ARE NO KITCHEN DETAILS.
 DISCREPANCY IN PLANS. 107.2.1.3 ADDITIONAL INFORMATION
 IS REQUIRED.
  
 5) SHEETS A5-A8 HAVE THE SAME NOTES THAT MAKE IT NOT
 CLEAR AS TO WHAT WORK IS BEING ACCOMPLISHED UNDER THIS
 PERMIT. DISCREPANCY IN PLANS. 107.2.1.3.
  
 6A) PLEASE NOTE THE PLANS AND PERMIT APPLICATION
 INDICATE THE RENOVATION OF 10 DORMITORY ROOMS. PLEASE
 REVIEW SECTION 224.7 OF THE 2014 FBC-ACCESSIBILITY
 CODE. 224.7 HOUSING AT A PLACE OF EDUCATION. HOUSING AT
 A PLACE OF EDUCATION SHALL COMPLY WITH THE REQUIREMENTS
 FOR TRANSIENT LODGING GUEST ROOMS IN SECTIONS 224 AND
 806, SUBJECT TO THE FOLLOWING EXCEPTIONS. THE TERM
 ?SLEEPING ROOM? IS INTENDED TO BE USED INTERCHANGEABLY
 WITH THE TERM ?GUEST ROOM? AS IT IS USED IN THE
 TRANSIENT LODGING STANDARDS.
  
 FBC ? ACCESS. CODE 224.1.1 ALTERATIONS.
 WHERE GUEST ROOMS ARE ALTERED OR ADDED, THE
 REQUIREMENTS OF 224 SHALL APPLY ONLY TO THE GUEST ROOMS
 BEING ALTERED OR ADDED UNTIL THE NUMBER OF GUEST ROOMS
 COMPLIES WITH THE MINIMUM NUMBER REQUIRED FOR NEW
 CONSTRUCTION.
 ADVISORY 224.1.1 ALTERATIONS.
 IN ALTERATIONS AND ADDITIONS, THE MINIMUM REQUIRED
 NUMBER OF ACCESSIBLE GUEST ROOMS IS BASED ON THE TOTAL
 NUMBER OF GUEST ROOMS ALTERED OR ADDED INSTEAD OF THE
 TOTAL NUMBER OF GUEST ROOMS PROVIDED IN A FACILITY.
 TYPICALLY, EACH ALTERATION OF A FACILITY IS LIMITED TO
 A PARTICULAR PORTION OF THE FACILITY. WHEN ACCESSIBLE
 GUEST ROOMS ARE ADDED AS A RESULT OF SUBSEQUENT
 ALTERATIONS, COMPLIANCE WITH 224.5 (DISPERSION) IS MORE
 LIKELY TO BE ACHIEVED IF ALL OF THE ACCESSIBLE GUEST
 ROOMS ARE NOT PROVIDED IN THE SAME AREA OF THE
 FACILITY.
  
 6B) FBC-ACCESS. CODE 224.4 GUEST ROOMS WITH
 COMMUNICATION FEATURES.
 IN TRANSIENT LODGING FACILITIES, GUEST ROOMS WITH
 COMMUNICATION FEATURES COMPLYING WITH 806.3 SHALL BE
 PROVIDED IN ACCORDANCE WITH TABLE 224.4.
  
 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2016-04-22 Cont ID  
Sent By vperez Date 2016-04-22 Time 13:10 Rev Time 0.00
Received By vperez Date 2016-04-22 Time 13:10 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-03-28 Cont ID  
Sent By vperez Date 2016-03-28 Time 09:01 Rev Time 0.00
Received By vperez Date 2016-03-28 Time 09:00 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-03-15 Cont ID  
Sent By vperez Date 2016-03-15 Time 10:58 Rev Time 0.00
Received By vperez Date 2016-03-15 Time 07:28 Sent To  
Notes
2016-03-15 10:58:52INITIAL ELECTRICAL PLAN REVIEW
  
 APPLICABLE CODES IN EFFECT:
 FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70- 2011 NEC
 COMMENTS:
  
 1. PLEASE PROVIDE A GENERAL NOTE TO INDICATE REQUIRED
 SEPARATE PERMITS FOR ALL LOW VOLTAGE SYSTEMS SHOWN ON
 SCOPE. FBC 107.3.5
 2. PLEASE PROVIDE A PANEL SCHEDULE FOR REFERENCE AS TO
 WHAT CIRCUIT DESIGNATION WILL POWER OR ENERGIZE THE NEW
 LIGHTING AND RECEPTACLES OUTLETS AND LABEL THE FLOOR
 PLAN WITH THE CIRCUIT DESIGNATION. FBC 107.3.5
 3. PROVIDE GENERAL NOTES TO REFLECT REQUIRED AFCI
 PROTECTED CIRCUITS AND TAMPER RESISTANT RECEPTACLES PER
 NEC 210.12A AND 406.12. A NOTE WILL SUFFICE
 4. ADDRESS WALL SPACE REQUIREMENTS FOR RECEPTACLE
 OUTLET THROUGHOUT UNITS SHOWN. NEC 210.52A2
 5. ADDRESS COUNTER WALL SPACE REQUIREMENTS FOR
 RECEPTACLE OUTLET THROUGHOUT KITCHEN UNITS SHOWN. NEC
 210.52C1
 6. SHOW THE REQUIRED OUTDOOR BALCONY RECEPTACLE OUTLETS
 PER NEC 210.52E3
 7. SHOW THE SMOKE DETECTOR PLACEMENT PER FBC RES 314
 REQUIREMENTS.
 8. FURTHER COMMENTS MAY FOLLOW UPON RESUBMITTAL. FEEL
 FREE TO CONTACT ME AT THE NUMBER BELOW, SHOULD YOU HAVE
 ANY QUESTIONS OR CONCERNS.
  
 VALENTINO PEREZ
 ELECTRICAL PLANS EXAMINER II
 561-805-6717
 [email protected]
  
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2016-04-13 Cont ID  
Sent By wjolin Date 2016-04-13 Time 15:28 Rev Time 0.00
Received By wjolin Date 2016-04-13 Time 15:25 Sent To  
Notes
2016-04-13 15:28:17900 SOUTH OLIVE AVENUE
 PERMIT #16030488
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 PROVISO:
  
 PROVIDE DRAWING NOTE INDICATING, "FIRE PROTECTION
 SYSTEMS SHALL REMAIN ACTIVE DURING DEMOLITION AND
 RENOVATION ACTIVITIES. IN THE EVENT A FIRE PROTECTION
 SYSTEM IS OUT OF SERVICE FOR MORE THAN 4-HOURS IN A
 24-HOUR PERIOD, THE BUILDING SHALL BE PLACED UNDER A
 FIRE WATCH. ALL FIRE WATCH REQUESTS MUST BE SUBMITTED
 BY EMAIL ([email protected]) AND APPROVED BY THE OFFICE OF
 THE FIRE MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY."
  
 SHEET E-1: NO SMOKE ALARMS PROVIDED NEAR BEDROOM A OF
 SUITE #201 AND NO SMOKE ALARMS PROVIDED FOR SUITE #202.
  
 WESLEY JOLIN
 ASSISTANT FIRE MARSHAL
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2016-03-24 Cont ID  
Sent By wjolin Date 2016-03-24 Time 09:48 Rev Time 0.00
Received By wjolin Date 2016-03-24 Time 09:26 Sent To  
Notes
2016-03-24 09:37:35900 SOUTH OLIVE AVENUE
 PERMIT #16030488
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 PROVISO:
  
 PROVIDE DRAWING NOTE INDICATING, "FIRE PROTECTION
 SYSTEMS SHALL REMAIN ACTIVE DURING DEMOLITION AND
 RENOVATION ACTIVITIES. IN THE EVENT A FIRE PROTECTION
 SYSTEM IS OUT OF SERVICE FOR MORE THAN 4-HOURS IN A
 24-HOUR PERIOD, THE BUILDING SHALL BE PLACED UNDER A
 FIRE WATCH. ALL FIRE WATCH REQUESTS MUST BE SUBMITTED
 BY EMAIL ([email protected]) AND APPROVED BY THE OFFICE OF
 THE FIRE MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY."
  
 SHEET E-1: NO SMOKE ALARMS PROVIDED NEAR BEDROOM A OF
 SUITE #201 AND NO SMOKE ALARMS PROVIDED FOR SUITE #202.
  
 WESLEY JOLIN
 ASSISTANT FIRE MARSHAL
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-04-27 Cont ID  
Sent By gjohnson Date 2016-04-27 Time 16:57 Rev Time 0.00
Received By gjohnson Date 2016-04-15 Time 10:20 Sent To  
Notes
2016-04-18 10:20:47C04

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-04-13 Cont ID  
Sent By wjolin Date 2016-04-13 Time 15:28 Rev Time 0.00
Received By wjolin Date 2016-03-25 Time 11:15 Sent To  
Notes
2016-03-25 11:16:04C02

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-03-24 Cont ID  
Sent By wjolin Date 2016-03-24 Time 09:48 Rev Time 0.00
Received By wjolin Date 2016-03-10 Time 16:22 Sent To  
Notes
2016-03-15 10:59:073/15 TO C07
2016-03-10 16:22:39C07

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2016-03-17 Cont ID  
Sent By jwitmer Date 2016-03-17 Time 15:25 Rev Time 0.00
Received By jwitmer Date 2016-03-17 Time 15:25 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2016-04-25 Cont ID  
Sent By ccole Date 2016-04-25 Time 14:39 Rev Time 0.00
Received By ccole Date 2016-04-25 Time 14:39 Sent To  
Notes
2016-04-25 14:44:35MECHANICAL PROVISO:
  
 THE CONTRACTOR MUST SUBMIT AC CHANGEOUT FORMS TO THE
 BUILDING DEPARTMENT PRIOR TO CALLING FOR 1ST
 INSPECTION.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2016-04-04 Cont ID  
Sent By ccole Date 2016-03-29 Time 10:01 Rev Time 0.00
Received By ccole Date 2016-03-29 Time 17:29 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-03-15 Cont ID  
Sent By ccole Date 2016-03-15 Time 16:41 Rev Time 0.00
Received By ccole Date 2016-03-15 Time 16:41 Sent To  
Notes
2016-03-15 16:46:341ST REVIEW: FBC 2014 MECHANICAL
 PERMIT #16030488
 3/15/16
  
 1) PROVIDE AC CHANGE OUT FORMS FOR ALL THE PROPOSED AHU
 AND FAN COIL REPLACEMENTS.
 2) PROVIDE AN INSTALLATION DETAIL FOR AHU-201 SHOWING
 HOW THE UNIT WILL BE ATTACHED AND SUPPORTED FROM THE
 STRUCTURE. PLEASE INCLUDE THE DETAILS FOR THE PRIMARY
 AND AUXILIARY CONDENSATE DISPOSAL SYSTEMS.
 3) SHEET MVP-1: PROVIDE A VENTILATION AIR CALCULATION.
 4) CLARIFY IF THE EXISTING CHILLER/CONDENSER SYSTEM IIS
 BEING REPLACED AND PROVIDE DETAILS IF APPLICABLE.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2016-04-27 Cont ID  
Sent By gjohnson Date 2016-04-27 Time 16:51 Rev Time 0.00
Received By gjohnson Date 2016-04-27 Time 16:51 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-04-12 Cont ID  
Sent By gjohnson Date 2016-04-12 Time 15:20 Rev Time 0.00
Received By gjohnson Date 2016-04-12 Time 15:20 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-03-17 Cont ID  
Sent By gjohnson Date 2016-03-17 Time 16:13 Rev Time 0.00
Received By gjohnson Date 2016-03-17 Time 16:13 Sent To  
Notes
***NONE***