|
 |
 |
 |
 |
 |
Plan Review Details - Permit 16030424
| Plan Review Stops For Permit 16030424 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2016-03-25 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2016-03-25 |
Time |
06:29 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-03-25 |
Time |
05:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2016-03-17 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2016-03-17 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2016-03-17 |
Time |
12:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2016-03-24 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2016-03-24 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2016-03-24 |
Time |
09:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-04-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-04-11 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-04-05 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2016-04-05 15:07:16 | RESUB ROUTED TO TKLARGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-03-26 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-03-26 |
Time |
05:07 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-03-10 |
Time |
10:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2016-03-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-03-25 |
Time |
06:29 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-03-25 |
Time |
05:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2016-04-11 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-04-11 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-04-11 |
Time |
09:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-03-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-03-21 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-03-21 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2016-03-21 11:25:08 | 1ST REVIEW: FBC 2014 MECHANICAL | | | PERMIT #16030424 | | | 3/21/16 | | | | | | 1) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE | | | NEW AHU'S #4 & 7- SEE SECTION C403.2.1 FBC-14 ENERGY | | | CONSERVATION. | | | 2) SHEET M1: ALL CODE REQUIRED DUCT SMOKE DETECTORS | | | SHALL BE INSTALLED IN THE RETURN AIR SYSTEMS, PLEASE | | | REVISE NOTE #1 AND INDICATE IF ALL THE SYSTEMS WILL BE | | | LINKED TOGETHER FOR FAN SHUT IF ANY SINGLE DETECTOR | | | ACTIVATES. | | | 3) M1: THE 10" FLEX DUCTS SUPPLYING 350 AND 340 CFMS | | | FOR AHU-3 & 5 NEED TO INCREASE TO 12". | | | 4) M1: THE EXHAUST FROM EF-3 SHALL DISCHARGE TO THE | | | OUTDOORS IN ACCORDANCE WITH SECTION 501.3 FBC-14 | | | MECHANICAL. | | | 5) M1: NOTE #4: INDICATES THE NEW CU'S TO BE MOUNTED ON | | | EXISTING ROOF STANDS- PLEASE PROVIDE ENGINEERED DETAILS | | | FOR TIE DOWN OF THE UNITS- SECTION 301.15 FBC-14 | | | MECHANICAL. | | | 6) M2: PLEASE PROVIDE THE REQUIRED AND PROVIDED CFM'S | | | IN THE O/A CALCULATION TABLE. | | | 7) PROVIDE NOTE AND DETAILS INDICATING HOW ACCESS FOR | | | SERVICE AND REPLACEMENT OF THE ABOVE CEILING AHU'S AND | | | MOTORIZED DAMPERS WILL BE PROVIDED. | | | 8) M2: PROVIDE HANGING, REINFORCEMENT, AND CONNECTION | | | DETAILS FOR THE RIGID DUCTS IN ACCORDANCE WITH TABLE | | | C403.2.7.2 FBC-14 ENERGY CONSERVATION. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2016-04-09 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-04-09 |
Time |
04:06 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-04-09 |
Time |
03:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-03-26 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-03-26 |
Time |
05:07 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-03-26 |
Time |
04:42 |
Sent To |
|
|
| Notes |
| 2016-03-26 05:07:00 | 1) PROVIDE SANITARY & WATER RISER DIAGRAMS FOR ALL | | | CHANGES TO THE PLUMBING SYSTEM.NOTE #5 ON SHT. M1 NOTES | | | THAT THE NEW SINK IS CONNECTING TO EXISTING SANITARY & | | | WATER LINES BUT AN EXISTING SINK IS NOT SHOWN ON | | | SHT.2.1. CLARIFY.FBC 107.3.5.1.3. | | | 2) THE WATER SUPPLY TO THE COFFEE MACHINES SHALL BE | | | PROTECTED AGAINST BACKFLOW PER 2014 FBC-PLUMBING | | | SEC.608.16.10. | | | 3) SUBMIT PIPING DETAILS FOR THE WATER HEATER AND PAN | | | DRAIN.WHAT TYPE OF FIXTURE IS THE PAN DRAIN DRAINING | | | TO? FBC 107.3.5.1.3. | | | 4) HOT WATER SHALL BE SUPPLIED TO THE BREAKROOM SINK | | | PER 2014 FBC-PLUMBING SEC.607.1. | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2016-03-15 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2016-03-15 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2016-03-15 |
Time |
11:39 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |