| Plan Review Stops For Permit 16030035 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-05-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-05-13 |
Time |
06:29 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-05-13 |
Time |
06:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-03-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-03-15 |
Time |
07:16 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-03-15 |
Time |
06:30 |
Sent To |
|
|
| Notes |
| 2016-03-15 07:16:25 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 16030035 | | | ADD: 100 S. DIXIE HWY. SUITE # 200 | | | CONT: NORTHSTAR CONSTRUCTION | | | TEL: 718-208-3011 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. MARCH 15/ 2016 | | | ACTION: DENIED | | | | | | 1) SHEET A2. THE COVERSHEET INDICATES THIS IS A | | | BUSINESS OCCUPANCY. PLEASE EXPLAIN THE USE OF THIS | | | SPACE IF THIS IS A BUSINESS OCCUPANCY. | | | 2014 FBC-B 304.1 BUSINESS GROUP B. BUSINESS GROUP B | | | OCCUPANCY INCLUDES, AMONG OTHERS, THE USE OF A BUILDING | | | OR STRUCTURE, OR A PORTION THEREOF, FOR OFFICE, | | | PROFESSIONAL OR SERVICE-TYPE TRANSACTIONS, INCLUDING | | | STORAGE OF RECORDS AND ACCOUNTS. | | | | | | 2) SHEET A2. THE PLANS INDICATE IN OFFICE # 5 2 DOORS | | | IN SERIES, PLEASE PROVIDE COMPLIANCE WITH: 2014 | | | FBC-ACCESSIBILITY CODE 404.2.6 DOORS IN SERIES. | | | | | | 3) SHEET A2 PLEASE PROVIDE COMPLIANCE WITH 2014 | | | FBC-ACCESSIBILITY CODE 403.5.2 FOR THE OFFICES 3-6. | | | | | | 4) SHEET A2 PLEASE SHOW COMPLIANCE WITH THE DOOR FROM | | | THE LOBBY INTO THE TENANT CORRIDOR2014 FBC-ACCESS. CODE | | | 404.2.4 MANEUVERING CLEARANCES. | | | FIGURE 404.2.4.1(A). | | | | | | 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-05-03 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-05-03 |
Time |
07:10 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-05-03 |
Time |
07:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-03-08 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-03-08 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-03-08 |
Time |
08:19 |
Sent To |
|
|
| Notes |
| 2016-03-08 11:04:11 | INITIAL ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA EXISTING BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 NEC | | | COMMENTS: | | | | | | 1.PLEASE DELETE FROM GENERAL NOTES ALL REFERENCES | | | PERTAINING TO RESIDENTIAL INSTALLATIONS. | | | 2.ADD GENERAL NOTES INDICATING NEC 410.130G | | | REQUIREMENTS FOR FLORESCENT LUMINAIRES. | | | 3.CLARIFY MEANS OF AUTOMATIC CONTROLS PER FBC ENERGY | | | CONSERVATION CODE 2014 5TH EDITION FOR ALL LIGHTINGS. | | | FBC EC 405.2 | | | 4.CORRECT TYPO TO INDICATE NEC 2011 NOT NEC 2010. | | | 5.SHOW LIGHTING AND POWER CIRCUIT DESIGNATION ON FLOOR | | | PLAN. FBC 107.3.5 | | | 6.SHOW PER NEC 700.12F THAT UNIT EQUIPMENT IS SERVED | | | FROM THE NORMAL LIGHTING IN THE AREA AND CONNECTED | | | AHEAD OF ANY LOCAL SWITCH. | | | 7.CLARIFY EXISTING PANEL C VOLTAGE. IS IT A SINGLE | | | PHASE 120/240? SHOWN AS 208/240. NOTE THAT SINGLE PHASE | | | IS CALLED OUT BUT PHASE A, B, C 3/PHASE ARRANGEMENT IS | | | SHOWN. REFLECT AN ACCURATE PANEL SCHEDULE FOR APPROVAL. | | | FBC 107.3.5 | | | 8.FURTHER COMMENTS MAY FOLLOW UPON RE-REVIEW. FEEL FREE | | | TO CONTACT ME AT THE NUMBER LISTED BELOW SHOULD YOU | | | HAVE ANY QUESTIONS OR CONCERNS. | | | | | | | | | | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2016-04-27 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-04-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-04-27 |
Time |
09:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2016-03-07 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-03-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-03-04 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2016-03-07 11:51:33 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | 1. SHEET A & A 3 - THERE IS AN INCORRECT REFERENCE TO | | | THE FIRE CODE - | | | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | | 5TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING | | | THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | | APPLICABLE CODES OR STANDARDS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-05-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-05-26 |
Time |
17:39 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-05-26 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2016-05-26 10:55:00 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2016-04-19 |
Time |
15:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-03-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-03-15 |
Time |
07:16 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-03-01 |
Time |
12:26 |
Sent To |
|
|
| Notes |
| 2016-03-08 11:04:27 | 3/8 TO C12 | | 2016-03-02 12:27:01 | C12 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2016-05-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-05-26 |
Time |
17:39 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-05-27 |
Time |
07:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2016-04-25 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-04-25 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-04-25 |
Time |
16:56 |
Sent To |
|
|
| Notes |
| 2016-04-25 17:09:09 | 2ND REVIEW: FBC 2014 MECHANICAL | | | PERMIT #16030035 | | | 4/25/16 | | | | | | 1) THE NEW AC PLAN SHOWS 5" DIAMETER FLEX DUCTS | | | CONNECTING TO NEW 4X4 DIFFUSERS- PLEASE CLARIFY HOW THE | | | 5" WILL CONNECT TO THE 4" COLLAR AND PROVIDE AN AIR | | | DEVICE SCHEDULE ON THE PLANS. | | | 2) THE VENTILATION CALCULATIONS ARE NOT IN COMPLIANCE | | | WITH TABLE 403.3 WHICH REQUIRES OFFICE SPACES TO BE | | | CALCULATED USING AN OCCUPANT DENSITY OF 5 PERSONS PER | | | SF. AND LOBBIES AT 10 PERSONS PER SF. THE VENTILATION | | | IS THEN CALCULATED AT 5CFMS PER PERSON + .06 CFMS PER | | | SF. | | | 3) PLEASE SHOW ALL DUCT ALTERATIONS IN THE NEW LOBBY | | | AND OPEN OFFICE ROOMS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-03-10 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-03-10 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-03-10 |
Time |
15:43 |
Sent To |
|
|
| Notes |
| 2016-03-10 15:53:21 | 1ST REVIEW: FBC 2014 MECHANICAL, EXISTING BUILDING | | | PERMIT #16030035 | | | 3/10/16 | | | | | | 1) REFER TO SECTION 809.2 FBC-14 EXISTING BUILDING: | | | ALTERED EXISTING SYSTEMS. | | | "IN MECHANICALLY VENTILATED SPACES, EXISTING MECHANICAL | | | VENTILATION SYSTEMS THAT ARE ALTERED, RECONFIGURED, OR | | | EXTENDED SHALL PROVIDE NOT LESS THAN 5 CUBIC FEET PER | | | MINUTE (CFM) (0.0024 M3/S) PER PERSON OF OUTDOOR AIR | | | AND NOT LESS THAN 15 CFM (0.0071 M3/S) OF VENTILATION | | | AIR PER PERSON; OR NOT LESS THAN THE AMOUNT OF | | | VENTILATION AIR DETERMINED BY THE INDOOR AIR QUALITY | | | PROCEDURE OF ASHRAE 62." PLEASE PROVIDE A VENTILATION | | | CALCULATION IN ACCORDANCE WITH TABLE 403.3 FBC-14 | | | MECHANICAL. | | | 2) THE PLAN IS IN COMPLETE: SOME DUCT SIZES NOT SHOWN, | | | DUCT TYPES NOT IDENTIFIED, CFM'S AT DIFFUSERS AND | | | RETURNS NOT SHOWN, RETURN GRILLS AT BACK ROOMS OF | | | OFFICES 3 & 4 NOT SHOWN. | | | 3) PLEASE CLARIFY IF THIS IS A PLENUM CEILING: PROVIDE | | | A NOTE. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2016-05-03 |
|
|
Cont ID |
|
| Sent By |
gearl |
Date |
2016-05-03 |
Time |
11:49 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-05-03 |
Time |
|
Sent To |
|
|
| Notes |
| 2016-05-20 18:09:59 | THERE IS NO PLUMBING WORK. | | 2016-05-03 11:49:07 | | | | | | | 1. 918.8 FBC PLUMBING -- VENT REQUIRED/ NEED TO HAVE | | | ONE VENT TO EXTENT TO THE OUTDOORS |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-03-12 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-03-12 |
Time |
06:38 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-03-12 |
Time |
06:22 |
Sent To |
|
|
| Notes |
| 2016-03-12 06:35:40 | 1) SHT. A - SCOPE OF WORK STATES THAT THERE IS NO | | | PLUMBING WORK TO BE DONE, YET THERE IS A PLUMBING SHEET | | | SHOWING A NEW HANDICAPPED TOILET ROOM, DRINKING | | | FOUNTAINS AND A BREAK ROOM. CLARIFY. IF NO PLUMBING | | | WORK IS TO BE DONE, REMOVE THIS SCOPE FROM THE PLANS | | | AND ALSO THE PERMIT APPLICATION. FBC 107.2.1. | | | 2) THE ADDRESS ON THE PLUMBING PLAN IS 9070 KIMBERLY | | | BLVD.#12, BOCA RATON. I DO NOT THINK THIS PLAN BELONGS | | | IN THIS PACKAGE. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | |
|
|