|
 |
 |
 |
 |
 |
Plan Review Details - Permit 16021059
| Plan Review Stops For Permit 16021059 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2016-03-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-03-11 |
Time |
06:00 |
Rev Time |
|
| Received By |
jwitmer |
Date |
2016-03-11 |
Time |
05:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2016-03-08 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-03-08 |
Time |
07:29 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-03-08 |
Time |
07:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2016-03-04 |
|
|
Cont ID |
|
| Sent By |
fstal |
Date |
2016-03-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
fstal |
Date |
2016-03-04 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2016-03-04 11:06:31 | COMMENTS: | | | LICENSED FIRE ALARM CONTRACTOR IS REQUIRED TO SUBMIT | | | SHOP DRAWINGS THAT INCLUDE A STAMPED APPROVAL BY THE | | | ENGINEER OF RECORD, VOLTAGE CALCULATIONS, BATTERY | | | CALCULATIONS, ALL WIRE SIZES AND TYPES, AND ALL DEVICE | | | TYPES AND LOCATIONS FOR APPROVAL PRIOR TO THE | | | INSTALLATION OF ANY PART OF THE SYSTEM. FIRE ALARM | | | INSTALLATION SHALL COMPLY WITH NFPA 70 AND 72, STATE | | | AND LOCAL ORDINANCES. | | | | | | NFPA 72-17.14.5: MANUAL FIRE ALARM BOXES SHALL BE | | | INSTALLED SO THAT THEY ARE CONSPICUOUS, UNOBSTRUCTED, | | | AND ACCESSIBLE. | | | NFPA 72-17.14.6: MANUAL FIRE ALARM BOXES SHALL BE | | | LOCATED WITHIN 60 IN. (1.52 M) OF THE EXIT DOORWAY | | | OPENING AT EACH EXIT ON EACH FLOOR. | | | | | | LICENSED FIRE SPRINKLER CONTRACTOR IS REQUIRED TO | | | SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO | | | INSTALLATION. FIRE SPRINKLER INSTALLATION SHALL COMPLY | | | WITH NFPA 13, STATE AND LOCAL ORDINANCES. | | | | | | FRANK STALLWORTH, FIRE INSPECTOR I | | | WEST PALM BEACH FIRE PREVENTION BUREAU | | | 500 N. DIXIE HWY | | | WEST PALM BEACH, FLORIDA 33401 | | | OFFFICE: 561-840-4780 | | | FAX: 561-840-4774 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-04-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-04-22 |
Time |
07:36 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-04-19 |
Time |
10:10 |
Sent To |
|
|
| Notes |
| 2016-04-20 10:10:31 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-03-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-03-11 |
Time |
06:01 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-02-29 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2016-03-08 07:29:45 | 3/8 TO BIN B07 | | 2016-02-29 11:01:15 | B07 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2016-03-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-03-11 |
Time |
06:01 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-03-11 |
Time |
06:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2016-04-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-04-22 |
Time |
07:36 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-04-22 |
Time |
07:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-03-10 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-03-10 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-03-10 |
Time |
08:56 |
Sent To |
|
|
| Notes |
| 2016-03-10 09:10:07 | 1ST REVIEW: FBC 2014 MECHANICAL | | | PERMIT #16021059 | | | 3/10/16 | | | | | | 1) M1.1: IT IS NOT CLEAR HOW THE RETURN AIR SYSTEMS | | | WILL FUNCTION FOR HP-1 & 2 SUPPLYING THE STORAGE AREAS- | | | SEE WALL TYPE-1 DETAIL ON SHEET A-1: IT APPEARS BY THE | | | DETAIL THAT THE WHOLE STORAGE AREA AND THE INDIVIDUAL | | | STORAGE ROOMS WILL BE CLOSED OFF FROM FLOOR TO | | | UNDERSIDE OF ROOF DECK. HOW WILL THE AIR RETURN BACK TO | | | THE UNITS? | | | 2) M1.1: THE 8X6 TRANSFER DUCT IS UNDERSIZED PER | | | SECTION 601.5. | | | 3) M1.1: INDICATE THE WIDTH AND GAGE OF THE STRAP | | | HANGERS AND THE DIAMETER OF THE RODS SHOWN IN THE M1 | | | DETAIL, AND INDICATE THE TYPE AND SIZE OF FASTENERS FOR | | | ANCHORING TO THE STRUCTURE ABOVE. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |