Plan Review Details - Permit 16020948
Plan Review Stops For Permit 16020948
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-03-18 Cont ID  
Sent By cthroop Date 2016-03-18 Time 11:29 Rev Time 0.00
Received By cthroop Date 2016-03-18 Time 11:29 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-03-09 Cont ID  
Sent By cthroop Date 2016-03-09 Time 15:47 Rev Time 0.00
Received By cthroop Date 2016-03-09 Time 10:51 Sent To Z
Notes
2016-03-09 15:58:231ST REVIEW: FBC 2014 5TH ED
 CHRISTOPHER S. THROOP, C.B.O.
 BLDG. PLANS EXAMINER ? PX3169
 (561) 805-6718
 [email protected]
  
 1. PROVIDE DETAIL FOR CMU INFILL WALL AT GARAGE DOOR
 OPENING. INCLUDE VERTICAL AND HORIZONTAL RE-INFORCING
 AND CONNECTION TO EXISTING SLAB AND BEAM.
  
 FBC 117 - THE BUILDING OFFICIAL MAY REQUIRE TESTS OR
 TEST REPORTS AS PROOF OF COMPLIANCE PLEASE BE ADVISED
 THE INSPECTOR MAY REQUIRE PREVIOUSLY COMPLETED WORK TO
 BE MADE ACCESSIBLE AND OPEN FOR INSPECTION OR REQUIRE
 ADDITIONAL DOCUMENTATION FOR ALL CONCEALED WORK
 PREVIOUSLY COMPLETED PURSUANT TO FBC 110 & FBC 117.
 FBC 110.1 GENERAL. CONSTRUCTION OR WORK FOR WHICH A
 PERMIT IS REQUIRED SHALL BE SUBJECT TO INSPECTION BY
 THE BUILDING OFFICIAL AND SUCH CONSTRUCTION OR WORK
 SHALL REMAIN ACCESSIBLE AND EXPOSED FOR INSPECTION
 PURPOSES UNTIL APPROVED.
 REQUIRED TESTS ARE TO BE MADE AT THE EXPENSE OF THE
 OWNER, OR AGENT, BY AN APPROVED TESTING LABORATORY OR
 OTHER APPROVED AGENCY.
  
 2. PROVIDE PRODUCT APPROVALS FOR IMPACT FIXED GLASS.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE WINDOW SUBMITTALS.
  
 3. BASED ON THE REQUIREMENTS OF THE EXISTING BUILDING
 CODE, SEC R322, IT MUST BE ESTABLISHED WHAT LEVEL OF
 WORK WILL BE REQUIRED. PROVIDE DOCUMENTATION
 ESTABLISHING "MARKET VALUE" OF THE RESIDENCE SO IT CAN
 BE DETERMINED IF THE PROPOSED IMPROVEMENTS EXCEED 50%
 OF MARKET VALUE. THE LEVEL OF WORK REQUIRED WILL BE
 DETERMINED BY THIS INFORMATION. SEE BELOW.
  
 [B] 402.2 FLOOD HAZARD AREAS.
 FOR BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS
 ESTABLISHED IN SECTION 1612.3 OF THE FLORIDA BUILDING
 CODE, BUILDING OR SECTION R322 OF THE FLORIDA BUILDING
 CODE, RESIDENTIAL, AS APPLICABLE, ANY ADDITION THAT
 CONSTITUTES SUBSTANTIAL IMPROVEMENT OF THE EXISTING
 STRUCTURE, AS DEFINED IN SECTION 202, SHALL COMPLY WITH
 THE FLOOD DESIGN REQUIREMENTS FOR NEW CONSTRUCTION, AND
 ALL ASPECTS OF THE EXISTING STRUCTURE SHALL BE BROUGHT
 INTO COMPLIANCE WITH THE REQUIREMENTS FOR NEW
 CONSTRUCTION FOR FLOOD DESIGN.
  
 FOR BUILDINGS AND STRUCTURES IN FLOOD HAZARD AREAS
 ESTABLISHED IN SECTION 1612.3 OF THE FLORIDA BUILDING
 CODE, BUILDING, OR SECTION R322 OF THE FLORIDA BUILDING
 CODE, RESIDENTIAL, AS APPLICABLE ANY ADDITIONS THAT DO
 NOT CONSTITUTE SUBSTANTIAL IMPROVEMENT OF THE EXISTING
 STRUCTURE, AS DEFINED IN SECTION 202, ARE NOT REQUIRED
 TO COMPLY WITH THE FLOOD DESIGN REQUIREMENTS FOR NEW
 CONSTRUCTION.
  
 FBC 202
 SUBSTANTIAL IMPROVEMENT. ANY REPAIR, RECONSTRUCTION,
 REHABILITATION, ALTERATION, ADDITION OR OTHER
 IMPROVEMENT OF A BUILDING OR STRUCTURE, THE COST OF
 WHICH EQUALS OR EXCEEDS 50 PERCENT OF THE MARKET VALUE
 OF THE STRUCTURE BEFORE THE IMPROVEMENT OR REPAIR IS
 STARTED. IF THE STRUCTURE HAS SUSTAINED SUBSTANTIAL
 DAMAGE, ANY REPAIRS ARE CONSIDERED SUBSTANTIAL
 IMPROVEMENT REGARDLESS OF THE ACTUAL REPAIR WORK
 PERFORMED.
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-03-09 Cont ID  
Sent By mvaldes Date 2016-03-09 Time 09:57 Rev Time 0.00
Received By mvaldes Date 2016-03-09 Time 09:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-03-18 Cont ID  
Sent By skennedy Date 2016-03-18 Time 11:39 Rev Time 0.00
Received By skennedy Date 2016-03-18 Time 11:39 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-03-14 Cont ID  
Sent By ccole Date 2016-03-14 Time 15:48 Rev Time 0.00
Received By ccole Date 2016-02-25 Time 10:40 Sent To  
Notes
2016-02-25 10:41:01ROUTED TO TIM LARGE

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2016-03-18 Cont ID  
Sent By skennedy Date 2016-03-18 Time 11:30 Rev Time 0.00
Received By skennedy Date 2016-03-18 Time 11:30 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2016-03-09 Cont ID  
Sent By cthroop Date 2016-03-09 Time 10:48 Rev Time 0.00
Received By cthroop Date 2016-03-09 Time 10:48 Sent To  
Notes
2016-03-09 10:51:361ST REVIEW: FBC 2014 5TH ED
 CHRISTOPHER S. THROOP, C.B.O.
 BLDG. PLANS EXAMINER ? PX3169
 (561) 805-6718
 [email protected]
  
 PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN AND
 TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURN STAMPED
 WITH A COPY OF RECEIPT AS APPLICABLE.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2016-03-18 Cont ID  
Sent By skennedy Date 2016-03-18 Time 11:39 Rev Time 0.00
Received By skennedy Date 2016-03-18 Time 11:30 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-03-14 Cont ID  
Sent By ccole Date 2016-03-14 Time 15:32 Rev Time 0.00
Received By ccole Date 2016-03-14 Time 15:32 Sent To  
Notes
2016-03-14 15:48:161ST REVIEW: FBC 2014 MECHANICAL
 PERMIT #16020948
 3/14/16
  
 1) IDENTIFY THE ROOMS, AND PROVIDE ROOM DIMENSIONS ON
 THE AC LAYOUT PLANS.
 2) PROVIDE A NORTH DIRECTIONAL ARROW ON THE AC PLANS.
 3) INDICATE THE SEER OF THE AC SYSTEM ON THE PLANS, AND
 SUBMIT AN AHRI CERTIFICATE.
 4) IT APPEARS THAT THE AHU IS IN THE ATTIC SPACE-
 PLEASE SHOW AN ACCESS PANEL ON THE PLAN, AND PROVIDE
 DETAILS IN ACCORDANCE WITH SECTION M1305.1.3 FBC-14
 RESIDENTIAL, AND SECTION R403.2.4 FBC-14 ENERGY
 CONSERVATION.
 5) PROVIDE A RETURN AIR SYSTEM THAT MEETS COMPLIANCE
 WITH SECTION M1602.1, AND M1602.4 FBC-14 RESIDENTIAL.
 6) PROVIDE MANUFACTURER'S SPECIFICATIONS FOR TIE DOWN
 OF THE AC CONDENSER AND CONSTRUCTION OF THE CONDENSER
 PAD-
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-02-25 Cont ID  
Sent By tklarge Date 2016-02-25 Time 11:50 Rev Time 0.00
Received By tklarge Date 2016-02-25 Time 11:50 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2016-03-11 Cont ID  
Sent By ajones Date 2016-03-11 Time 11:35 Rev Time 0.00
Received By ajones Date 2016-03-11 Time 11:35 Sent To M
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy