| Plan Review Stops For Permit 16020862 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2016-07-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-07-27 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-07-27 |
Time |
17:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2016-07-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-07-14 |
Time |
18:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-07-14 |
Time |
18:19 |
Sent To |
|
|
| Notes |
| 2016-07-14 18:19:00 | PLAN | | | REVIEW COMMENTS | | | 3RD REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE WIND ZONE PRESSURES ON SHEET S.1 HAVE NOT BEEN | | | REVISED TO REFLECT EXPOSURE D. FBCR 301.2.1 | | | | | | 2) THE WIND PRESSURES FOR ROOF ZONE 3 ARE NOT CORRECT | | | IN THE CALCULATIONS THAT WERE SUBMITTED BY THE | | | ENGINEER. ROOF ZONES TWO (2) AND THREE (3) HAVE THE | | | SAME NEGATIVE PRESSURES (-73.08 PSF). THE UPLIFT | | | PRESSURES FOR ROOF ZONE THREE (3) SHOULD BE MORE. FBC | | | R301.2.1 | | | | | | 3) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE | | | 16' X 8' SECTIONAL GARAGE DOOR +/- 25.5 PSF ARE NOT | | | ADEQUATE. THE PLANS SPECIFY THE REQUIRED PRESSURES FOR | | | THAT DOOR AS +38.7, -42.16 PSF. SUBMIT NEW PRODUCT | | | APPROVALS WITH ADEQUATE DESIGN PRESSURES. FBC R301.2.1 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-05-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-05-20 |
Time |
18:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-05-20 |
Time |
17:32 |
Sent To |
|
|
| Notes |
| 2016-05-20 18:57:21 | PLAN | | | REVIEW COMMENTS | | | 2ND REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE PROPOSED STRUCTURE IS LOCATED WITHIN 600 FEET OF | | | A LARGE LAKE THAT IS AN EXPOSURE D CONDITION. | | | THEREFORE, THE STRUCTURE IS REQUIRED TO BE DESIGNED FOR | | | EXPOSURE D. FBC-R 301.2.1.4.3 THE WIND ZONE PRESSURES | | | WERE NOT INCREASED TO REFLECT THE CHANGE FROM EXPOSURE | | | C TO EXPOSURE D. FBC 301.2.1 | | | | | | 2) THE LAST WIND ZONE LISTED ON SHEET S-1 SHOULD BE | | | ZONE 5 AND NOT ZONE 3. FBC 107.2.1 | | | | | | 3) THE ENERGY COMPLIANCE FORMS ARE REQUIRED TO HAVE THE | | | NAME OF THE PERSON THAT PREPARES THEM. FBC ENERGY | | | CONSERVATION R405.4.2 | | | | | | 4) THE DESIGNER OF RECORD FOR THE PLANS THAT WERE | | | SUBMITTED IS JOHN D. HOLT. MR. HOLT'S FLORIDA | | | PROFESSIONAL ENGINEER'S LICENSE HAS BEEN SUSPENDED. HE | | | CAN NO LONGER SIGN AND SEAL PLANS. A NEW DESIGNER OF | | | RECORD IS REQUIRED. | | | | | | 5) THE PRODUCT APPROVAL'S THAT WERE APPROVED IN WRITING | | | BY MR. HOLT WILL NEED TO BE REVIEWED AND APPROVED IN | | | WRITING BY THE NEW DESIGNER OF RECORD. | | | | | | 6) THE DESIGN LOAD PRESSURES FOR THE PRODUCT APPROVALS | | | WILL NEED TO BE CHECKED TO SEE THAT THEY MEET THE | | | REVISED OPENING PRESSURES FOR EXPOSURE D SPECIFIED ON | | | THE PLANS. FBC-R 301.1 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-04-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-04-08 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-04-06 |
Time |
19:08 |
Sent To |
|
|
| Notes |
| 2016-04-08 15:57:51 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE PROPOSED STRUCTURE IS LOCATED WITHIN 600 FEET OF | | | A LARGE LAKE THAT IS AN EXPOSURE D CONDITION. | | | THEREFORE, THE STRUCTURE IS REQUIRED TO BE DESIGNED FOR | | | EXPOSURE D. FBC-R 301.2.1.4.3 | | | | | | 2) THE ENERGY COMPLIANCE FORMS CONTAINS ERRORS. THE | | | DESIGN LOCATION IS WEST PALM BEACH, NOT BELLE GLADE. | | | THE PLANS SPECIFY R-5 INSULATION ON THE EXTERIOR | | | CONCRETE BLOCK WALLS AND THE FORM HAS R-30. THE OWNER'S | | | OR AGENTS SIGNATURE IS REQUIRED ON THE FORM NOT THE | | | NAME OF THEIR COMPANY. THE WALL BETWEEN THE LIVING | | | SPACE AND THE GARAGE, THE ADJACENT WALL, IS NOT LISTED | | | ON THE ENERGY COMPLIANCE FORM. THE PLAN SPECIFIES R-11 | | | IN THE ADJACENT WALL AND R-13 IS REQUIRED BY SECTION | | | R402.1.1 OF THE ENERGY CODE. | | | | | | 3) THE PRODUCT APPROVAL FOR THE SECTIONAL GARAGE DOOR | | | IS FOR THE 2010 CODE VERSION. THE 2014 FLORIDA BUILDING | | | CODE APPLIES TO THIS PROJECT. | | | | | | 4) THE DESIGN LOAD PRESSURES LISTED IN THE PRODUCT | | | APPROVAL FOR THE SECTIONAL GARAGE DOOR ARE NOT | | | ADEQUATE, BASED ON THE OPENING PRESSURES SPECIFIED ON | | | THE PLANS. FBC-R 301.1 | | | | | | 5) THE DESIGN LOAD PRESSURES LISTED IN THE PRODUCT | | | APPROVAL FOR THE DOUBLE OUTSWING FRONT ENTRY DOOR ARE | | | NOT ADEQUATE, BASED ON THE OPENING PRESSURES SPECIFIED | | | ON THE PLANS. FBC-R 301.1 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | 2016-03-28 13:15:52 | OPENED IN ERROR. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-04-29 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-04-29 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-04-29 |
Time |
14:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-03-03 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-03-03 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-03-03 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2016-03-03 13:35:42 | INITIAL ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA BUILDING CODE RESIDENTIAL 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 NEC | | | COMMENTS: | | | | | | 1.PLEASE ADD A RECEPTACLE FOR WALL SPACE IN MASTER | | | BEDROOM, UNDER 2GANG SWITCH SHOWN. FBC RES E3901.2.2 | | | 2.PROVIDE ON PANEL SCHEDULE THE AIC RATING OF | | | EQUIPMENT. | | | 3.SHOW ON ELECTRICAL CALCULATION 2- 1500VA SMALL | | | APPLIANCE CIRCUITS NOT 1 AS CALCULATED. FBC RERS E | | | 3703.2 | | | 4. LABEL GDO TO BE GFCI PROTECTED ON FLOOR PLAN. FBC | | | RES E3902.2 | | | 4.FEEL FREE TO CONTACT ME AT THE NUMBER BELOW, SHOULD | | | YOU HAVE ANY QUESTIONS OR CONCERNS. | | | | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2016-08-05 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2016-08-05 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2016-08-03 |
Time |
09:09 |
Sent To |
|
|
| Notes |
| 2016-08-04 09:09:58 | RESUB ROUTED TO ESCHNEIDER VIA ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2016-07-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-07-27 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-07-20 |
Time |
10:14 |
Sent To |
|
|
| Notes |
| 2016-07-21 10:14:26 | RESUB ROUTED TO ESCHNEIDER VIA ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-07-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-07-14 |
Time |
18:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-06-20 |
Time |
09:53 |
Sent To |
|
|
| Notes |
| 2016-06-21 09:53:38 | RESUB ROUTED TO ESCHNEIDER VIA ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-05-20 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-05-20 |
Time |
18:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-04-21 |
Time |
13:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-04-08 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-04-08 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-02-23 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2016-03-03 13:36:13 | 3/3 TO CAROLINE | | 2016-02-23 12:54:55 | R19 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
P |
Date |
2016-08-29 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-08-29 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-08-29 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2016-08-29 11:09:28 | 2016 - MU - 20851, PAID $9766.49 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2016-07-27 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-07-27 |
Time |
17:09 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-07-27 |
Time |
17:09 |
Sent To |
|
|
| Notes |
| 2016-07-27 17:23:43 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2016-07-14 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-07-14 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-07-14 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2016-07-14 14:01:46 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2016-04-06 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-04-06 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-04-06 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2016-04-06 14:11:37 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2016-05-02 |
|
|
Cont ID |
|
| Sent By |
jvalido |
Date |
2016-05-02 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
jvalido |
Date |
2016-05-02 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2016-05-02 13:16:50 | FLORIDA ENERGY CODE 2014 | | | | | | R103.1.1.2 CODE COMPLIANCE CERTIFICATION. | | | THE BUILDING'S OWNER, THE OWNER'S ARCHITECT, OR OTHER | | | AUTHORIZED AGENT LEGALLY DESIGNATED BY THE OWNER SHALL | | | CERTIFY THAT THE BUILDING IS IN COMPLIANCE WITH THE | | | CODE, AS PER SECTION 553.907, FLORIDA STATUTES, PRIOR | | | TO RECEIVING THE PERMIT TO BEGIN CONSTRUCTION OR | | | RENOVATION. | | | | | | PROVIDE NAME AND SIGNATURE ON PREPARED BY: AND DATE ON | | | FORM R405-2014. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-03-28 |
|
|
Cont ID |
|
| Sent By |
jvalido |
Date |
2016-03-28 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
jvalido |
Date |
2016-03-28 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2016-03-28 13:20:22 | R403.6.1 - HEATING AND COOLING EQUIPMENT SHALL BE SIZED | | | IN ACCORDANCE WITH ACCA MANUAL S BASED ON THE EQUIPMENT | | | LOADS CALCULATED IN ACCORDANCE WITH ACCA MANUAL J OR | | | OTHER APPROVED HEATING AND COOLING CALCULATION | | | METHODOLOGIES, BASED ON BUILDING LOADS FOR THE | | | DIRECTIONAL ORIENTATION OF THE BUILDING. THE | | | MANUFACTURER AND MODEL NUMBER OF THE OUTDOOR AND INDOOR | | | UNITS (IF SPLIT SYSTEM) SHALL BE SUBMITTED ALONG WITH | | | THE SENSIBLE AND TOTAL COOLING CAPACITIES AT THE DESIGN | | | CONDITIONS DESCRIBED IN SECTION R302.1. | | | | | | R403.6.1.1 COOLING EQUIPMENT CAPACITY. COOLING ONLY | | | EQUIPMENT SHALL BE SELECTED SO THAT ITS TOTAL CAPACITY | | | IS NOT LESS THAN THE CALCULATED TOTAL LOAD, BUT NOT | | | MORE THAN 1.15 TIMES GREATER THAN THE TOTAL LOAD | | | CALCULATED ACCORDING TO THE PROCEDURE SELECTED IN | | | SECTION 403.6, OR THE CLOSEST AVAILABLE SIZE PROVIDED | | | BY THE MANUFACTURER?S PRODUCT LINES. THE CORRESPONDING | | | LATENT CAPACITY OF THE EQUIPMENT SHALL NOT BE LESS THAN | | | THE CALCULATED LATENT LOAD. | | | | | | PROVIDE APPROVED HEAT LOAD CACULATIONS AS PER 403.6.1 | | | AND 403.6.1.1. CONFIRM CFM QUANTITIES. AHU CFM | | | QUANTITIES MUST MATCH OR EXCEED CFM QUANTITIES SHOWN ON | | | SUPPLY OUTLETS ON PLANS. SPECIFIED UNIT ON EQUIPMENT | | | SCHEDULE DOES NOT MEET CFM QUANTITIES SPECIFIED ON | | | PLANS FOR SUPPLY OUTLETS. PROVIDE MANUFACTURER DATA | | | SHEETS OF EQUIPMENT TO BE INSTALLED. | | | | | | CONDENSER UNIT MOUNTING DETAIL IS DIFFERENT THAN | | | CONDENSER LOCATION NOTES ON PLANS. MAKE CORRECTIONS AS | | | PER FBC AND MANUFACTURER SPECIFICATIONS. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2016-05-04 |
|
|
Cont ID |
|
| Sent By |
gearl |
Date |
2016-05-04 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
gearl |
Date |
2016-05-04 |
Time |
13:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2016-02-28 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-02-28 |
Time |
04:45 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-02-28 |
Time |
04:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2016-08-05 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2016-08-05 |
Time |
15:08 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2016-08-05 |
Time |
15:08 |
Sent To |
PC |
|
| Notes |
| 2016-08-05 08:34:27 | ROUTED TO ERIC SCHNEIDER |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
2016-07-26 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2016-07-26 |
Time |
09:20 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2016-07-26 |
Time |
09:20 |
Sent To |
B |
|
| Notes |
| 2016-07-26 09:25:19 | FAILED | | | | | | 1) REPEAT COMMENT: SHEET S.P AND THE SURVEY SHOW | | | DIFFERING DIMENSIONS FOR THE A/C PAD FROM THE HOUSE (SP | | | 1.5 FEET VS. SURVEY 1 FOOT), WHICH AFFECTS THE DISTANCE | | | TO THE PROPERTY LINE. BOTH DRAWINGS SHALL SHOW THE SAME | | | DIMENSION CONDITION. | | | | | | 2) REPEAT COMMENT: YOU ARE REQUIRED TO PROVIDE A | | | CONTINUOUS SIDEWALK IN FRONT OF THE PROPERTY. PLEASE | | | CONTACT THE ENGINEERING SERVICES DIVISION AT (561) | | | 494-1040 FOR DETAILS. THE SIDEWALK SHALL BE SHOWN ON | | | THE SITE PLAN. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | | | 2016-07-21 13:14:41 | ROUTED TO ERIC SCHNEIDER |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2016-06-30 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2016-06-30 |
Time |
11:15 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2016-06-30 |
Time |
11:15 |
Sent To |
B |
|
| Notes |
| 2016-06-30 11:17:36 | FAILED | | | | | | 1) REPEAT COMMENT: SHEET S.P AND THE SURVEY SHOW | | | DIFFERING DIMENSIONS FOR THE A/C PAD FROM THE HOUSE (SP | | | 1.5 FEET VS. SURVEY 1 FOOT), WHICH AFFECTS THE DISTANCE | | | TO THE PROPERTY LINE. BOTH DRAWINGS SHALL SHOW THE SAME | | | DIMENSION CONDITION. | | | | | | 2) REPEAT COMMENT: YOU ARE REQUIRED TO PROVIDE A | | | CONTINUOUS SIDEWALK IN FRONT OF THE PROPERTY. PLEASE | | | CONTACT THE ENGINEERING SERVICES DIVISION AT (561) | | | 494-1040 FOR DETAILS. THE SIDEWALK SHALL BE SHOWN ON | | | THE SITE PLAN. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2016-05-06 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2016-05-06 |
Time |
10:31 |
Rev Time |
0.75 |
| Received By |
eschneid |
Date |
2016-05-06 |
Time |
09:51 |
Sent To |
|
|
| Notes |
| 2016-05-06 10:03:55 | FAILED | | | | | | 1) REPEAT COMMENT - PRIOR TO ZONING APPROVAL OF THIS | | | PERMIT, SUBMIT A LANDSCAPE BUILDING PERMIT WHICH | | | COMPLIES WITH CITY LANDSCAPE REQUIREMENTS. NO LANDSCAPE | | | PERMIT HAS BEEN SUBMITTED. | | | | | | 2) NEW COMMENT: SHEET S.P AND THE SURVEY SHOW DIFFERING | | | DIMENSIONS FOR THE A/C PAD FROM THE HOUSE (SP 1.5 FEET | | | VS. SURVEY 1 FOOT), WHICH AFFECTS THE DISTANCE TO THE | | | PROPERTY LINE. BOTH DRAWINGS SHALL SHOW THE SAME | | | DIMENSION CONDITION. | | | | | | 3) PLEASE REMEMBER - A SEPARATE DRIVEWAY PERMIT IS | | | REQUIRED WHICH SHALL ADHERE TO THE FOLLOWING: | | | | | | A.SECTION 94-313 - A SINGLE DRIVEWAY WITH A WIDTH OF NO | | | GREATER THAN 20 FEET AT THE PROPERTY LINE OR WHERE THE | | | DRIVEWAY ADJOINS THE APRON IF THE APRON IS NOT LOCATED | | | WHOLLY WITHIN THE RIGHT-OF-WAY. | | | B. SECTION 94-482(A) - REQUIRED OFF-STREET PARKING | | | SPACES FOR LESS THAN THREE RESIDENTIAL DWELLING UNITS | | | SHALL BE PROVIDED ON THE PROPERTY ON WHICH THE UNITS | | | ARE LOCATED. REQUIRED PARKING MAY BE LOCATED IN A FRONT | | | YARD; HOWEVER, THE LESSER OF 1,000 SQUARE FEET OR 75 | | | PERCENT OF THE FRONT YARD AREA SHALL BE LANDSCAPED WITH | | | LIVING PLANT MATERIAL (SUCH AS GRASS, GROUND COVER, | | | SHRUBS, HEDGES, VINES OR TREES). PROVIDE AREA | | | CALCULATIONS. | | | C. SECTION 94-482(D)1 NEW OFF-STREET PARKING SPACES AND | | | DRIVEWAYS WITHIN A FRONT YARD OR A CORNER SIDE YARD | | | SHALL BE SET BACK A MINIMUM OF FIVE FEET FROM A FRONT | | | AND/OR CORNER SIDE PROPERTY LINE AND THREE FEET FROM A | | | SIDE OR REAR PROPERTY LINE, EXCEPT FOR THAT PORTION OF | | | THE DRIVEWAY ADJOINING THE APRON. PROVIDE DIMENSIONS. | | | | | | 4) PLEASE NOTE - YOU WILL BE REQUIRED TO PROVIDE A | | | CONTINUOUS SIDEWALK IN FRONT OF THE PROPERTY. PLEASE | | | CONTACT THE ENGINEERING SERVICES DIVISION AT (561) | | | 494-1040 FOR DETAILS. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2016-03-09 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2016-03-09 |
Time |
09:30 |
Rev Time |
1.00 |
| Received By |
eschneid |
Date |
2016-03-08 |
Time |
17:26 |
Sent To |
|
|
| Notes |
| 2016-03-09 10:58:00 | FAILED | | | | | | 1) THE SETBACK DIMENSION ON THE SITE PLAN SHALL SHOW | | | THE HOUSE IS 25 FEET FROM THE SOUTHEAST CORNER OF THE | | | HOUSE TO THE PROPERTY LINE (SAME MEASURE POINT AS THE | | | SURVEY) SINCE THE FRONT OF THE HOUSE IS NOT PARALLEL TO | | | THE FRONT PROPERTY LINE. | | | | | | 2) PROVIDE HEIGHT DIMENSIONS TO THE PEAK, MIDPOINT AND | | | EAVES IN ACCORDANCE WITH FOLLOWING CITY CODE | | | REQUIREMENT - HEIGHT OF STRUCTURE MEANS THE VERTICAL | | | DISTANCE FROM THE AVERAGE ELEVATION OF THE FINISHED | | | GRADE OF THE STRUCTURE TO THE HIGHEST PORTION OF THE | | | STRUCTURE, SUBJECT TO SPECIFIED HEIGHT REQUIREMENTS OF | | | THIS CHAPTER. FOR BUILDINGS, THE HEIGHT SHALL BE | | | MEASURED AS THE VERTICAL DISTANCE FROM THE AVERAGE | | | ELEVATION OF THE FINISHED GRADE OF THE BUILDING TO THE | | | HIGHEST POINT OF THE TOP OF THE STRUCTURE OF A FLAT | | | ROOF, OR TO THE DECK LINE OF A MANSARD ROOF, OR TO THE | | | MEAN HEIGHT LEVEL BETWEEN EAVES AND RIDGE FOR GABLE, | | | HIP, AND GAMBREL ROOFS. | | | | | | 3) PROVIDE THE SETBACK DIMENSIONS TO THE A/C EQUIPMENT | | | AND THE A/C PAD. | | | | | | 4) A SEPARATE DRIVEWAY PERMIT IS REQUIRED WHICH SHALL | | | ADHERE TO THE FOLLOWING: | | | | | | A.SECTION 94-313, CIRCULAR DRIVEWAY OPENINGS SHALL NOT | | | EXCEED TEN FEET IN WIDTH AT THE PROPERTY LINE. PROVIDE | | | DIMENSIONS. | | | B. SECTION 94-482(A) - REQUIRED OFF-STREET PARKING | | | SPACES FOR LESS THAN THREE RESIDENTIAL DWELLING UNITS | | | SHALL BE PROVIDED ON THE PROPERTY ON WHICH THE UNITS | | | ARE LOCATED. REQUIRED PARKING MAY BE LOCATED IN A FRONT | | | YARD; HOWEVER, THE LESSER OF 1,000 SQUARE FEET OR 75 | | | PERCENT OF THE FRONT YARD AREA SHALL BE LANDSCAPED WITH | | | LIVING PLANT MATERIAL (SUCH AS GRASS, GROUND COVER, | | | SHRUBS, HEDGES, VINES OR TREES). PROVIDE AREA | | | CALCULATIONS. | | | C. SECTION 94-482(D)1 NEW OFF-STREET PARKING SPACES AND | | | DRIVEWAYS WITHIN A FRONT YARD OR A CORNER SIDE YARD | | | SHALL BE SET BACK A MINIMUM OF FIVE FEET FROM A FRONT | | | AND/OR CORNER SIDE PROPERTY LINE AND THREE FEET FROM A | | | SIDE OR REAR PROPERTY LINE, EXCEPT FOR THAT PORTION OF | | | THE DRIVEWAY ADJOINING THE APRON. PROVIDE DIMENSIONS. | | | D. SECTION 94-482(D)5 - FOR CIRCULAR DRIVEWAYS THE | | | INTERIOR ARC MAY BE AN IRREGULAR SHAPE, BUT SHALL HAVE | | | A MINIMUM RADIUS OF FIVE FEET, AS DEPICTED IN FIGURE | | | XV-1. THE INTERIOR ARC SHALL BE LANDSCAPED WITH LIVING | | | PLANT MATERIAL. PROVIDE DIMENSIONS. | | | | | | 5) THE SURVEY AND SITE PLAN SHOW DIFFERENT DRIVEWAY | | | CONDITIONS - SIZE AND LOCATION. ALL PLANS SHALL SHOW | | | SAME CONDITIONS. | | | | | | 6) PRIOR TO ZONING APPROVAL OF THIS PERMIT, SUBMIT A | | | LANDSCAPE BUILDING PERMIT WHICH COMPLIES WITH CITY | | | LANDSCAPE REQUIREMENTS. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. |
|
|