| 2016-03-01 08:54:39 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 16020859 |
| | ADD: 8055 IRONHORSE BLVD./ CLUBHOUSE |
| | CONT: DARLING CONSTRUCTION |
| | TEL: 772-215-9818 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: TUES. MARCH 01/2016 |
| | ACTION: DENIED |
| | |
| | NOTICE: 2014 FBC-ACCESSIBILITY CODE, SCOPE 201.1. THIS |
| | CODE ESTABLISHES STANDARDS FOR ACCESSIBILITY TO PLACES |
| | OF PUBLIC ACCOMMODATION AND COMMERCIAL FACILITIES BY |
| | INDIVIDUALS WITH DISABILITIES, PRIVATE CLUBS PURSUANT |
| | TO SECTION 553.505, F.S. |
| | |
| | 1) SHEET ALR-3.0 THE NEW GUEST MENS LOCKER ROOM DOES |
| | NOT SHOW COMPLIANCE WITH THE 2014 FBC-ACCESS. CODE |
| | BENCHES SHALL COMPLY WITH 903.1 (2-6). |
| | |
| | 2) SHEET ALR-3.0 THE NEW MENS TV ROOM: |
| | 2A) SEE NOTE 11 WALL HUNG TV SHEET ALR-5.0 DETAIL 3 |
| | WALL MOUNTED TV MUST MEET REACH RANGES, 2014 |
| | FBC-ACCESSIBILITY CODE EITHER; |
| | |
| | 308.2.1FORWARD REACH UNOBSTRUCTED. WHERE A FORWARD |
| | REACH IS UNOBSTRUCTED, THE HIGH FORWARD REACH SHALL BE |
| | 48 INCHES (1220 MM) MAXIMUM AND THE LOW FORWARD REACH |
| | SHALL BE 15 INCHES (380 MM) MINIMUM ABOVE THE FINISH |
| | FLOOR OR GROUND. |
| | |
| | 308.3.2 OBSTRUCTED HIGH REACH. WHERE A CLEAR FLOOR OR |
| | GROUND SPACE ALLOWS A PARALLEL APPROACH TO AN ELEMENT |
| | AND THE HIGH SIDE REACH IS OVER AN OBSTRUCTION, THE |
| | HEIGHT OF THE OBSTRUCTION SHALL BE 34 INCHES (865 MM) |
| | MAXIMUM AND THE DEPTH OF THE OBSTRUCTION SHALL BE 24 |
| | INCHES (610 MM) MAXIMUM. THE HIGH SIDE REACH SHALL BE |
| | 48 INCHES (1220 MM) MAXIMUM FOR A REACH DEPTH OF 10 |
| | INCHES (255 MM) MAXIMUM. |
| | |
| | 2B) SEE DETAIL # 7 CABINETRY NO DIMENSIONS GIVEN. 2014 |
| | FBC-ACCESSIBILITY CODE 902.3 HEIGHT. THE TOPS OF WORK |
| | SURFACES SHALL BE 28 INCHES (710 MM) MINIMUM AND 34 |
| | INCHES (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR |
| | GROUND. |
| | |
| | |
| | 3) SHEET ALR-3.1: |
| | 3A) NOTE # 7. OPENINGS FROM THE MENS AND LADIES LOCKER |
| | ROOM TO ATTENDANT ROOM. PLEASE REVIEW OPENING TO THE |
| | LOCKER ROOM TO BE 3 FEET 3 INCHES TO THE BOTTOM OF THE |
| | OPENING. 2014 FBC-ACCESSIBILITY CODE 902.3 HEIGHT. THE |
| | TOPS OF WORK SURFACES SHALL BE 28 INCHES (710 MM) |
| | MINIMUM AND 34 INCHES (865 MM) MAXIMUM ABOVE THE FINISH |
| | FLOOR OR GROUND. |
| | |
| | 3B) NOTE # 9 MILLWORK CABINETRY. 2014 FBC-ACCESSIBILITY |
| | CODE 902.3 HEIGHT. THE TOPS OF WORK SURFACES SHALL BE |
| | 28 INCHES (710 MM) MINIMUM AND 34 INCHES (865 MM) |
| | MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. |
| | |
| | 3C) SINK IN MILLWORK CABENTRY TO COMPLY WITH 2014 |
| | FBC-ACCESS. CODE 606.3 HEIGHT. |
| | LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT |
| | OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES |
| | (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. |
| | |
| | 3D) THE DOOR BETWEEN THE MENS TV ROOM AND THE |
| | ATTENDANTS ROOM ON THE ATTENDANTS ROOM SIDE DOES NOT |
| | HAVE THE REQUIRED 18 INCHES ON THE LATCH SIDE OF THE |
| | DOOR. 2014 FBC-ACCESS. CODE 404.2.4 MANEUVERING |
| | CLEARANCES. |
| | |
| | 3E) THE WOMENS TV ROOM NOTE 11 NEW WALL HUNG TV. 2014 |
| | FBC-ACCESSIBILITY CODE EITHER; |
| | |
| | 308.2.1FORWARD REACH UNOBSTRUCTED. WHERE A FORWARD |
| | REACH IS UNOBSTRUCTED, THE HIGH FORWARD REACH SHALL BE |
| | 48 INCHES (1220 MM) MAXIMUM AND THE LOW FORWARD REACH |
| | SHALL BE 15 INCHES (380 MM) MINIMUM ABOVE THE FINISH |
| | FLOOR OR GROUND. |
| | |
| | 308.3.2 OBSTRUCTED HIGH REACH. WHERE A CLEAR FLOOR OR |
| | GROUND SPACE ALLOWS A PARALLEL APPROACH TO AN ELEMENT |
| | AND THE HIGH SIDE REACH IS OVER AN OBSTRUCTION, THE |
| | HEIGHT OF THE OBSTRUCTION SHALL BE 34 INCHES (865 MM) |
| | MAXIMUM AND THE DEPTH OF THE OBSTRUCTION SHALL BE 24 |
| | INCHES (610 MM) MAXIMUM. THE HIGH SIDE REACH SHALL BE |
| | 48 INCHES (1220 MM) MAXIMUM FOR A REACH DEPTH OF 10 |
| | INCHES (255 MM) MAXIMUM. |
| | |
| | 4) PLEASE ALSO REVIEW 2014 FBC-ACCESS. CODE 202.4.1 |
| | DISPROPORTIONATE COST. ALTERATIONS MADE TO PROVIDE AN |
| | ACCESSIBLE PATH OF TRAVEL TO THE ALTERED AREA WILL BE |
| | DEEMED DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN |
| | THE COST EXCEEDS 20% OF THE COST OF THE ALTERATION TO |
| | THE PRIMARY FUNCTION AREA. COSTS THAT MAY BE COUNTED AS |
| | EXPENDITURES REQUIRED TO PROVIDE AN ACCESSIBLE PATH OF |
| | TRAVEL MAY INCLUDE: (I) COSTS ASSOCIATED WITH PROVIDING |
| | AN ACCESSIBLE ENTRANCE AND AN ACCESSIBLE ROUTE TO THE |
| | ALTERED AREA; (II) COSTS ASSOCIATED WITH MAKING |
| | RESTROOMS ACCESSIBLE, SUCH AS INSTALLING GRAB BARS, |
| | ENLARGING TOILET STALLS, INSULATING PIPES, OR |
| | INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COSTS |
| | ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH |
| | AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT, |
| | INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT |
| | TELEPHONE (TTY); (IV) COSTS ASSOCIATED WITH RELOCATING |
| | AN INACCESSIBLE DRINKING FOUNTAIN. |
| | |
| | 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |
| | 3) |
| | |
| | |
| | |
| | |
| | |