| Plan Review Stops For Permit 16020625 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2016-06-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-06-24 |
Time |
18:41 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-06-24 |
Time |
18:41 |
Sent To |
|
|
| Notes |
| 2016-06-24 19:00:40 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1-PROVIDE PRODUCT APPROVAL (2 COPIES) FOR: | | | A) GARAGE EXTERIOR SWING DOOR AS SHOWN ON PLANS. PLANS | | | CALL FOR SOLID CORE METAL DOOR WITH RAISED PANELS. | | | JELD-WEN DOOR INFORMATION SUBMITTED IS FOR STEEL DOOR | | | WITH GLAZING. IT DOESN'T MATCH PLANS AND DOESN'T HAVE A | | | FLORIDA PRODUCT APPROVAL NUMBER. | | | B) ROOF SHINGLES AS SHOWN ON PLANS. | | | C) PRECAST LINTELS AS SPECIFIED ON PLANS. NOA | | | 14-0903.03 SUBMITTED IS FOR 4", 6" & 12" LINTELS. NEED | | | NOA FOR 8" LINTELS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-04-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-04-25 |
Time |
07:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-04-25 |
Time |
07:41 |
Sent To |
|
|
| Notes |
| 2016-04-25 07:42:49 | RESIDENTIAL (R3) ADDITION, SECOND BUILDING REVIEW | | | CHECKLIST. | | | CODE: FBC-5TH EDITION (2014). | | | | | | NOTE: BUILDING REVIEW MAY BE APPROVED WITH PROVISO. | | | REQUIRED INFORMATION WILL BE PROVIDED AFTER THE PERMIT | | | IS ISSUED AND BEFORE REQUESTING INSPECTIONS. FEES MAY | | | APPLY. CONTRACTOR TO ADVICE IF PROVISO OPTION IS | | | PREFERRED AT THIS TIME. | | | | | | 1- ENERGY CALCULATIONS SUBMITTED: | | | A) NEED THE NAME OF THE PERSON COMPLETING THE | | | COMPLIANCE REPORT. AS REQUIRED BY SEC. R405.4.2 OF | | | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | | | | | B) NEED THE INSPECTION CHECKLIST AS REQUIRED BY SEC. | | | R405.4.2 OF FBC-ENERGY CONSERVATION, 5TH EDITION | | | (2014). | | | | | | C) NEED THE EPL DISPLAY CARD SIGNED BY THE BUILDER AS | | | REQUIRED BY SEC. R405.4.3 OF FBC-ENERGY CONSERVATION, | | | 5TH EDITION (2014). | | | | | | D) PROVIDE COMPLETE INFORMATION ON TOP OF THE FORM, | | | INCLUDING THE NAME OF THE BUILDER. SEC. R101.5.1.1.2 OF | | | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | | | | | NOTE: | | | LABEL FOR WINDOWS AND DOORS SHOWING THE U-FACTOR AND | | | SHGC FACTOR SPECIFIED ON THE ENERGY CALCULATIONS WILL | | | BE REQUIRED WHEN THE ENERGY CALCULATIONS ARE NOT USING | | | THE DEFAULT FACTOR FOR GLAZING. | | | | | | 2- ICYNENE ICC EVALUATION REPORT SUBMITTED IS EXPIRED. | | | PROVIDE CURRENT EVALUATION REPORT. AND ARCHITECT OF | | | RECORD TO REVIEW/APPROVE REPORT PRIOR TO SUBMITTAL. | | | SEC. R316 FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | | | 3- SHEET S1.0: REVISE DESIGN PARAMETERS INFORMATION | | | ITEM #5. WHAT DOES "ALL CALCULATIONS ARE BASED ON 2010" | | | STANDS FOR? REVISE AS REQUIRED. SEC. 107.2.1 CITY | | | AMENDMENTS. (REPEAT COMMENT). | | | | | | 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.002(33) FOR: | | | A) GARAGE EXTERIOR SWING DOOR AS SHOWN ON PLANS. PLANS | | | CALL FOR SOLID CORE METAL DOOR WITH RAISED PANELS. | | | JELD-WEN DOOR INFORMATION SUBMITTED IS FOR STEEL DOOR | | | WITH GLAZING. IT DOESN'T MATCH PLANS AND DOESN'T HAVE A | | | FLORIDA PRODUCT APPROVAL NUMBER. | | | | | | B) ROOF SHINGLES AS SHOWN ON PLANS (REPEAT COMMENT). | | | | | | C) ROOF SELF ADHERED UNDERLAYMENT AS SPECIFIED ON THE | | | TYPICAL WALL SECTIONS. NOA 13-0514.12 SUBMITTED IS FOR | | | FLAT ROOF ASSEMBLIES. IT'S NOT A SELF ADHERED | | | UNDERLAYMENT FOR SHINGLES. | | | | | | D) PRECAST LINTELS AS SPECIFIED ON PLANS. FLORIDA | | | PRODUCT APPROVAL FL158-R7 SUBMITTED IS INCOMPLETE . | | | IT'S MISSING THE TECHNICAL DRAWINGS THAT WERE SUBMITTED | | | FOR APPROVAL. PROVIDE COMPLETE INFORMATION. | | | | | | ***PLEASE PROVIDE REPONSE LETTER ADDRESSING EACH | | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | | DRAWING. DON'T STAPLE OLD DRAWINGS TO PLANS. SUBMIT OLD | | | DRAWINGS FOR REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-03-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-03-14 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-03-14 |
Time |
09:46 |
Sent To |
|
|
| Notes |
| 2016-03-14 11:27:00 | RESIDENTIAL (R3) ADDITION, BUILDING REVIEW COMMENTS. | | | CODE: FBC-5TH EDITION (2014). | | | | | | 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.) | | | FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED | | | PLANS AND COPY OF THE PAID RECEIPT IF FEES ARE DUE. | | | COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED LAND | | | DEVELOPMENT CODE. | | | | | | 2- PROVIDE ENERGY CALCULATIONS. SEC. R101.4.3 OF | | | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | | | | | 3- SPECIFY ATTIC ACCESS SIZE AND LOCATION SHOWING | | | COMPLIANCE WITH SEC. R807 OF FBC-RESIDENTIAL, 5TH | | | EDITION (2014). | | | | | | 4- SPECIFY CARBON MONOXIDE ALARMS BY THE BEDROOMS AS | | | REQUIRED BY SEC. R315 OF FBC-RESIDENTIAL, 5TH EDITION | | | (2014). INCLUDING EXISTING BEDROOMS. | | | | | | 5- MASONRY GABLE WALL VERTICAL REINFORCEMENT SPACING TO | | | COMPLY WITH SEC. R609.4.2 OF FBC-RESIDENTIAL, 5TH | | | EDITION (2014). REVISE PLANS AS REQUIRED. | | | | | | 6- PROVIDE ICC EVALUATION REPORT (2 COPIES) FOR THE | | | FOAM INSULATION SPECIFIED ON PLANS. ARCHITECT OF RECORD | | | TO REVIEW/APPROVE REPORT PRIOR TO SUBMITTAL. | | | | | | 7- SHEET S1.0: REVISE DESIGN PARAMETERS INFORMATION. | | | WHAT DOES "ALL CALCULATIONS ARE BASED ON 2010" STANDS | | | FOR? REVISE AS REQUIRED. SEC. 107.2.1 CITY AMENDMENTS. | | | | | | 8- SHEET S2.0: | | | A) UPDATE THE BUILDING CODE SPECIFIED ON THE | | | ENGINEERING CRITERIA AND TRUSS DESIGN CRITERIA. | | | REFERENCE CURRENT CODE. CHAPTER 553 F. S. | | | | | | B) REVISE THE BOTTOM CHORD LIVE LOAD. SEE NOTES "B" AND | | | "G" OF TABLE R301.5 AND REVISE AS REQUIRED. | | | | | | C) REVISE DESIGN PARAMETERS INFORMATION. WHAT DOES "ALL | | | CALCULATIONS ARE BASED ON 2010" STANDS FOR? REVISE AS | | | REQUIRED. SEC. 107.2.1 CITY AMENDMENTS. | | | | | | 9- SHEET S3.0: UPDATE THE DESIGN PARAMETERS AND | | | CASCRETE PERIMETER BEAM SYSTEM UPLIFT CALCULATIONS | | | INFORMATION. REFER TO THE CURRENT 2014 CODE. CHAPTER | | | 553 F.S. | | | | | | 10- SPECIFY HOW COMPLYING WITH THE HEATING REQUIREMENTS | | | OF SEC. R303.9 OF FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | | | 11- CLARIFY IF THE SOFFIT VENT SPECIFIED ON THE EAST | | | ELEVATION ON SHEET A2.0 IS A DECORATIVE VENT OR WORKING | | | VENT. IF WORKING VENT, THEN PRODUCT APPROVAL (2 COPIES) | | | IS REQUIRED BY FAC 61G20-3.002(33. | | | | | | 12- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.002(33) FOR: | | | A) DOUBLE FRENCH DOORS WITH SIDELITES AS SHOWN ON PLANS | | | AND THAT MEETS THE CALCULATED DESIGN PRESSURES. | | | NOTE: FLORIDA FL7630.2 PRODUCT APPROVAL SUBMITTED IS | | | FOR SINGLE DOOR WITH SIDELITE AND IT DOESN'T MEET THE | | | DESIGN PRESSURES CALCULATED BY THE ARCHITECT ON SHEET | | | S2.0. | | | | | | B) GARAGE EXTERIOR SWING DOOR AS SHOWN ON PLANS. | | | | | | C) SOFFIT VENT. SEE ITEM #11 ABOVE. | | | | | | D) ROOF SHINGLES AS SHOWN ON PLANS. | | | | | | E) ROOF SELF ADHERED UNDERLAYMENT AS SPECIFIED ON THE | | | TYPICAL WALL SECTIONS. | | | | | | F) PRECAST LINTELS AS SPECIFIED ON PLANS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-04-20 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-04-20 |
Time |
09:40 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-04-20 |
Time |
09:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-03-03 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-03-03 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-03-03 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2016-03-03 11:31:11 | JOB PERMIT NUMBER: 16020625 | | | JOB ADDRESS: 308 COLONIAL RD | | | WEST PALM BEACH FLORIDA | | | DATE: MARCH 3 2016 | | | ELECTRICAL PLAN REVIEW COMMENTS | | | | | | THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION | | | HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF | | | THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC, | | | (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST | | | PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF | | | SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED. | | | | | | - ADJUST AND RECONFIGURE ACCORDINGLY. LOAD CALCULATIONS | | | SHOW SQUARE FOOTAGE AS 1766 AND SHEET SP1 STATES 2865 | | | SQFT TOTAL ? FURTHERMORE SHOW ALL PANEL SCHEDULES AND | | | SERVICE EQUIPMENT/PANELBOARDS LOCATIONS EXISTING & NEW | | | ON FLOOR PLANS . WBA 107 | | | - INSERT INTERSYSTEM BONDING ON RISER DIAGRAM AS WELL | | | AS AIC RATINGS OF EQUIPMENT OCPD NEC 110.9, 110.10 NEC | | | 250.94. EXISTING METER CAN LUGS MUST BE RATED FOR DUAL | | | WIRE NEC 110.14 | | | - INSULATIONS OF FEEDER CONDUCTORS IS SHOWN AS THHN | | | WHICH IS NOT RATED FOR WET LOCATIONS NEC 300.5 , 300.7 | | | . SEALING IS REQUIRED IF EXPOSED TO DIFFERENT | | | TEMPERATURES. | | | - ROMEX IS A BRAND NAME PROPER ELECTRICAL TERMINOLOGY | | | IS NM CABLE PER NEC 334 | | | - FAN BOXES MUST BE SECURED AND INSTALLED ACCORDING TO | | | NEC 314.27 C | | | - SMOKE / CARBON ALARMS REQUIRED PER RESIDENTIAL CODE | | | SECTIONS 314 & 315 | | | - RECESSED LIGHTS SHALL BE 75 % HIGH EFFICIENCY , IC | | | RATED, AND SEALED TO NOT COMPROMISE BUILDING THERMAL | | | ENVELOPE. ( 2 CFM ) FBC ER 404.1.1 / 402.4.4 | | | | | | | | | | | | PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE | | | MENTIONED DEFICIENCIES. | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | | RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE | | | LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE | | | STANDARD CITY RE-SUBMITTAL FORM. THE NARRATIVE SHOULD | | | INCLUDE THE PLAN REVIEWER?S COMMENTS AND YOUR RESPONSE | | | OR ACTION TO SAME. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE | | | PREVIOUSLY REVIEWED SHEETS FOR COMPARISON. | | | CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | FBC 2014 5TH ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 516-805-6713 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2016-06-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-06-27 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-06-02 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2016-06-02 13:48:27 | RESUB ROUTED TO JGOMEZ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-04-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-04-26 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-04-12 |
Time |
11:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-04-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-04-06 |
Time |
17:35 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-03-21 |
Time |
14:41 |
Sent To |
|
|
| Notes |
| 2016-03-21 14:41:50 | IMPACT FEES ROUTED TO JGOMEZ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-03-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-03-14 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-02-17 |
Time |
14:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2016-04-06 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-04-06 |
Time |
17:34 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-04-06 |
Time |
17:34 |
Sent To |
|
|
| Notes |
| 2016-04-06 17:34:59 | $242.50 PAID. MU-2016-006368. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2016-03-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-03-14 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-03-14 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2016-03-14 11:13:08 | 1- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.) | | | FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED | | | PLANS AND COPY OF THE PAID RECEIPT IF FEES ARE DUE. | | | COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED LAND | | | DEVELOPMENT CODE. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2016-06-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-06-27 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-06-27 |
Time |
10:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-04-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-04-26 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-04-26 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2016-04-26 10:59:44 | RESIDENTIAL (R3) ADDITION, MECHANICAL REVIEW CHECKLIST. | | | CODE: FBC-5TH EDITION (2014). | | | | | | NOTE: MECHANICAL REVIEW MAY BE APPROVED WITH PROVISO. | | | REQUIRED INFORMATION WILL BE PROVIDED AFTER THE PERMIT | | | IS ISSUED AND BEFORE REQUESTING INSPECTIONS. FEES MAY | | | APPLY. CONTRACTOR TO ADVICE IF PROVISO OPTION IS | | | PREFERRED AT THIS TIME. | | | | | | 1- CLARIFY/REVISE THE INFORMATION SHOWN ON SHEET M.1 | | | FOR BEDROOM #2 AIR SUPPLY GRILL . WHAT'S 168/109? | | | WHAT'S THE ACTUAL QUANTITY OF CFM'S ENTERING TO THIS | | | ROOM? WHAT'S THE SIZE OF THE GRILL?. SEC. 107.2.1 CITY | | | AMENDMENTS. | | | | | | 2- PROVIDE THE NAME AND SIGNATURE OF PERSON RESPONSIBLE | | | FOR THE DESIGN. SEC. 107.2.1 CITY AMENDMENTS. | | | | | | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | | DRAWING. DON'T STAPLE OLD DRAWINGS TO PLANS. SUBMIT OLD | | | DRAWINGS FOR REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2016-02-27 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-02-27 |
Time |
06:51 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-02-27 |
Time |
06:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2016-06-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-06-27 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-06-27 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2016-06-27 10:26:16 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1-PROVIDE PRODUCT APPROVAL (2 COPIES) FOR: | | | A) ROOF SHINGLES AS SHOWN ON PLANS. | | | | | | APPROVED PRODUCT APPROVALS: | | | A) POLYGLASS SHINGLES UNDERLAYMENT NOA 14-0717.08. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2016-04-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-04-26 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-04-26 |
Time |
07:55 |
Sent To |
|
|
| Notes |
| 2016-04-26 10:29:43 | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.002(33) FOR: | | | A) ROOF SHINGLES AS SHOWN ON PLANS (REPEAT COMMENT). | | | | | | B) ROOF SELF ADHERED UNDERLAYMENT AS SPECIFIED ON THE | | | TYPICAL WALL SECTIONS. NOA 13-0514.12 SUBMITTED IS FOR | | | FLAT ROOF ASSEMBLIES. IT'S NOT A SELF ADHERED | | | UNDERLAYMENT FOR SHINGLES. | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2016-03-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-03-14 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-03-14 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2016-03-14 15:51:18 | 1- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.002(33) FOR: | | | A) ROOF SHINGLES AS SHOWN ON PLANS. | | | | | | B) ROOF SELF ADHERED UNDERLAYMENT AS SPECIFIED ON THE | | | TYPICAL WALL SECTIONS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2016-04-22 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2016-04-22 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2016-04-22 |
Time |
|
Sent To |
|
|
| Notes |
| 2016-04-22 09:27:35 | ZONING PASSED WITH THE FOLLOWING PROVISO: | | | | | | 1.) SEPARATE PERMIT APPLICATION AND REVIEW REQUIRED FOR | | | DRIVEWAY AND WALK MODIFICATION. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2016-02-26 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2016-02-26 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2016-02-26 |
Time |
08:26 |
Sent To |
|
|
| Notes |
| 2016-02-26 17:08:00 | ** FAILED ** | | | | | | 1.) THE VALUE OF THE CONSTRUCTION ($130,000) EXCEEDS 50 | | | PERCENT OF THE STRUCTURE'S VALUE ($90,854) ACCORDING TO | | | THE P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, | | | PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE | | | SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE | | | SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A | | | LANDSCAPE PLAN DEMONSTRATING COMPLIANCE SHALL BE | | | INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE SITE DOES | | | NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE ZONING | | | APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE PERMIT AND | | | IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING MATERIAL | | | TO BRING THE SITE INTO CONFORMITY. | | | | | | 2.) PROVIDE ALL BUILDING SETBACK DIMENSIONS IN THE | | | PROPOSED SITE PLAN, INCLUDING, BUT NOT LIMITED TO THE | | | RESIDENCE (EXISTING SIDE), ALL MECHANICAL EQUIPMENT, | | | RELOCATED PORTION OF THE DRIVEWAY, ETC. | | | | | | 3.) A SEPARATE PERMIT APPLICATION IS REQUIRED FOR THE | | | DRIVEWAY MODIFICATION. | | | | | | 4.) THE SURVEY SHOWS THE LOCATION OF THE TWO (2) A/C | | | UNITS ON THE NORTHWEST CORNER OF THE RESIDENCE, FACING | | | NORTH; HOWEVER, THE SITE PLAN SHOWS THE A/C UNITS | | | RELOCATED TO THE WEST SIDE OF THE RESIDENCE. PLEASE | | | CLARIFY. IF THE A/C UNITS ARE TO BE RELOCATED, A | | | SEPARATE PERMIT APPLICATION WILL BE REQUIRED FOR THE | | | RELOCATION OF THE A/C UNITS. | | | | | | 5.) THE LOT AREA IN THE PROJECT DATA TABLE NEEDS TO BE | | | CORRECTED TO 12,870 SQ. FT. | | | | | | PLEASE NOTE THAT ANY CHANGES ON THE RESUBMITTED PLANS | | | MAY RESULT IN ADDITIONAL COMMENTS. CONTACT LINDA LOUIE | | | @ (561) 822-1458 IF YOU HAVE QUESTIONS. | | | |
|
|