Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-09-29 Cont ID  
Sent By skennedy Date 2016-09-29 Time 17:56 Rev Time 0.00
Received By skennedy Date 2016-08-03 Time   Sent To  
Notes
2016-09-29 18:03:002ND REVIEW: FBC 2010
  
 AS NO PRODUCT APPROVAL IS AVAILABLE FOR THE DOOR
 PRODUCTS, PROVIDE EVIDENCE OF COMPLIANCE WITH THE
 REQUIREMENTS OF FBC 1715.5.5.3. OR AN ENGINEER'S LETTER
 DETERMINING THE DOOR IS ENGINEERED IN ACCORDANCE WITH
 ACCEPTED ENGINEERING PRACTICES PER FBC 1215.5.3.2. THE
 TESTING YOU PROVIDED IS AN ASTM TEST APPARENTLY
 PERFORMED BY THE DOOR MANUFACTURER AND NOT A THIRD
 PARTY TESTING AGENCY, BUT APPARENTLY DEMONSTRATING
 CERTAIN RESISTANCE. ADDITIONALLY YOU HAVE PROVIDED A
 SHOP SUBMITTAL WITH EVIDENCE OF REVIEW BY THE
 ENGINEERING FIRM. THIS IS HELPFUL, BUT THERE IS NO
 PRODUCT APPROVAL OR AN ENGINEER SIGNING AND SEALING THE
 SUBMITTAL TAKING RESPONSIBILITY TO ASSURE THE CODE
 REQUIREMENTS ARE MET, AS I DO NOT BELIEVE THE
 EXCEPTIONS TO FBC 1715.5.5.3 ARE APPLICABLE,
  
 WHAT YOU SHOULD DO IS PROVIDE THIS TESTING INFORMATION
 TO THE ENGINEER OF RECORD OR A DELEGATED ENGINEER AND
 THAT PERSON SHOULD ANALYZE THE TEST REPORTS AND THE
 PRODUCT INFORMATION ALONG WITH THE DESIGN PARAMETERS
 FOR THE BUILDING AND THE MANUFACTURERS INSTALLATION
 INSTRUCTION AND DETERMINE THAT THE DOORS ARE ENGINEERED
 IN ACCORDANCE WITH ACCEPTED ENGINEERING PRACTICE AND
 SIGN AND SEAL A LETTER TO THAT EFFECT. SUCH LETTER, IF
 BY A DELEGATED ENGINEER MUST BEAR EVIDENCE OF REVIEW BY
 THE ENGINEER OF RECORD. YOU SHOULD THEN SUBMIT ALL OF
 THAT INFORMATION TO ME IN DUPLICATE AND I WILL ISSUE
 THE PERMIT.
  
  
 STEVEN KENNEDY, CBO
 CHIEF PLANS EXAMINER
 (561) 805-6710
 [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-06-07 Cont ID  
Sent By skennedy Date 2016-02-17 Time 09:35 Rev Time 0.00
Received By skennedy Date 2016-02-17 Time 09:36 Sent To  
Notes
2016-06-07 09:37:53PROVIDE PRODUCT APPROVALS/SHOP DRAWINGS OR DELEGATED
 ENGINEERED SUBMITTALS WITH EVIDENCE OF REVIEW BY THE
 EOR.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-09-29 Cont ID  
Sent By skennedy Date 2016-09-29 Time 17:56 Rev Time 0.00
Received By skennedy Date 2016-02-01 Time 09:35 Sent To  
Notes
***NONE***