Plan Review Details - Permit 16020449
Plan Review Stops For Permit 16020449
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2016-03-10 Cont ID  
Sent By cthroop Date 2016-03-10 Time 14:17 Rev Time 0.00
Received By cthroop Date 2016-03-10 Time 13:47 Sent To  
Notes
2016-03-09 18:22:423/9/2016 MECH FAIL - SMALL DENIED C. JV.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-03-04 Cont ID  
Sent By rlecky Date 2016-03-04 Time 12:47 Rev Time 0.00
Received By rlecky Date 2016-03-02 Time 14:50 Sent To  
Notes
2016-03-04 13:08:3816020449
 7230 WINDING BAY LN.
 INTERIOR REMODEL
  
  
 PLANS ISSUED WITH THE FOLLOWING PROVISO.
  
 REMODELING OF AN EXISTING STRUCTURE IS REQUIRED TO
 INCLUDE INTERCONNECTED SMOKE ALARMS BOTH WITHIN AND
 OUTSIDE EACH SLEEPING AREA. IF THE BUILDING HAS GAS
 APPLIANCES, AN ATTACHED GARAGE OR A FIREPLACE, A CARBON
 MONOXIDE DETECTOR IS REQUIRED WITHIN TEN FEET OF EACH
 ROOM USED FOR SLEEPING. 2014 FBC R314, 315
  
 PROVIDE GFCI PROTECTED RECEPTACLES IN REMODELED BATH
 ROOMS. NEC 210.8; FBC R 3902
  
 VERIFY THE NEW HIGH HAT CEILING LIGHTING FIXTURES THAT
 ARE IN CONTACT WITH INSULATION ARE IC RATED. NEC
 410.116; FBC R 4004
  
 CEILING ELECTRICAL BOXES IF INTENDED FOR SUPPORT OF
 PADDLE FANS MUST BE LISTED FOR THAT USE. NEC 422.18;
 FBC R 3905.9
  
  
 ROBERT LECKY
 ELECTRICAL PLANS EXAMINER
 561-373-3701
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2016-02-20 Cont ID  
Sent By tklarge Date 2016-02-20 Time 08:58 Rev Time 0.00
Received By tklarge Date 2016-02-20 Time 08:58 Sent To  
Notes
2016-02-20 08:58:39GAS PLAN REVIEW
 A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE
 REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK.
 PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT
 SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE
 SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC.
 107.2.1.
  
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-03-15 Cont ID  
Sent By cpuell Date 2016-03-15 Time 17:24 Rev Time 0.00
Received By cpuell Date 2016-03-15 Time 13:19 Sent To  
Notes
2016-03-15 13:19:19RESUB ROUTED TO JVALIDO

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-03-10 Cont ID  
Sent By jvalido Date 2016-03-10 Time 14:17 Rev Time 0.00
Received By cthroop Date 2016-02-12 Time 13:21 Sent To  
Notes
2016-03-09 19:12:423/9/2016 MECH FAILED - SMALL DENIED C. JV.
2016-02-12 13:21:53R01

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2016-03-15 Cont ID  
Sent By jvalido Date 2016-03-15 Time 15:16 Rev Time 0.00
Received By jvalido Date 2016-03-15 Time 15:16 Sent To  
Notes
2016-03-15 15:16:25MECHANICAL CONTRACTOR TO PROVIDE SEPERATE PLANS AND
 PULL A SEPERATE PERMIT FOR AHU RELOCATION. ALL OTHER
 HVAC EQUIPMENT TO REMAIN IN EXISTING LOCATIONS. AS PER
 SUBMITTED PLANS.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-03-09 Cont ID  
Sent By jvalido Date 2016-03-09 Time 19:10 Rev Time 0.00
Received By jvalido Date 2016-03-09 Time 19:10 Sent To  
Notes
2016-03-09 18:06:30107.2.1 PROVIDE ON PLANS LOCATION OF MAKE UP AIR FOR
 NEW GAS BURNING FIREPLACE. CONFIRM IF THERE IS AN
 EXISTING DUCT. IF IT IS SUFFICIENT FOR NEW GAS BURNING
 FIRE PLACE. PROVIDE MANUFACTURER SPECIFICATION.

Review Stop P PLUMBING
Rev No 1 Status P Date 2016-02-20 Cont ID  
Sent By tklarge Date 2016-02-20 Time 08:57 Rev Time 0.00
Received By tklarge Date 2016-02-20 Time 08:31 Sent To  
Notes
2016-02-20 08:57:33PROVISO
 SUBMIT SANITARY RISER FOR ALL CHANGES MADE TO THE
 PLUMBING SYSTEM PRIOR TO THE FIRST PLUMBING
 INSPECCTION.FBC 107.3.5.3.
  
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  