Plan Review Details - Permit 16020418
| Plan Review Stops For Permit 16020418 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2016-05-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-05-16 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-05-14 |
Time |
10:30 |
Sent To |
|
|
| Notes |
| 2016-05-14 11:29:38 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 16020418 / STADIUM, NATIONALS | | | CLUBHOUSE & PRACTICE FIELDS | | | W. P. B. PERMIT: 16020419/ ASTROS CLUBHOUSE | | | W. P. B. PERMIT: 16020417/ TEAM STORE & BAR | | | | | | ADD: 5444 N. HAVERHILL RD. | | | | | | CONT: HUNT CONSTRUCTION | | | | | | TEL: 561-568-8045 / MICHAEL SANCHEZ | | | | | | E-MAIL: [email protected] | | | | | | HCS ARCHITECT/ INTERIOR DESIGNER | | | ASSOCIATE ARCHITECT/ INTERIOR DESIGNER | | | GLIDDEN SPINA INTERIORS | | | STRUCTURAL ENGINEER | | | BLISS & NYITRAY, INC | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 3RD REVIEW | | | DATE: SAT. MAY 17/016 | | | ACTION: BUILDING PROVISO | | | | | | | | | 1) BUILDING PROVISO: SHEET 0349_A2-120 & 0350_A2-121. | | | ROOF TOP MECHANICAL SCREENS. DETAILS 8 &9/ A6.21 & | | | 08/A7.21 . FINAL DIMENSIONS & LOCATION OF THE | | | MECHANICAL SCREEN TO BE DETERMINED BY THE LOCATION AND | | | SIZE OF THE MECHANICAL EQUIPMENT. | | | | | | 2A) BUILDING PROVISO: DELEGATE ENGINEER. ADDITIONAL | | | INFORMATION REQUIRED. 2014 FBC-B 410.4./ FBC-B 410.4, | | | LOADING REQUIREMENTS FOR THE RAISED DECK( TABLE | | | 1607.1), HANDRAIL , GUARDRAIL ASSEMBLY (1607.8) AND | | | STAIR(TABLE 1607.1). | | | | | | 2B) PROVISO: RESPONSE COMMENT: 1ST ROUND OF COMMENTS. | | | FOR BOTH PLATFORMS PLEASE SHOW HOW COMPLIANCE WITH | | | VERTICAL ACCESSIBILITY WILL BE MET.2014 201.1.1 | | | VERTICAL ACCESSIBILITY REQUIREMENTS. | | | | | | 2C ) BUILDING PROVISO: DELEGATE ENGINEER. THE INTERVIEW | | | ROOM 50/ 11709 ON THE RIGHT INDICATES A STAGE DETAIL ON | | | SHEET 07 / A2.712 . 107.2.1.3 ADDITIONAL INFORMATION | | | REQUIRED. 2014 FBC-B 410.4./ FBC-B 410.4, LOADING | | | REQUIREMENTS FOR THE RAISED DECK( TABLE 1607.1), | | | HANDRAIL , GUARDRAIL ASSEMBLY (1607.8) AND STAIR(TABLE | | | 1607.1). | | | | | | 3) REVISION REQUIRED. SHEET 0392_A2-421 NOW DOES SHOW | | | THE 6 HANDICAPPED SHEETS ON THE SAME LEVEL AS WELL AS | | | THE STRUCTURAL SHEET 0612_S4.31 DETAIL 8. THE 2 SHEETS | | | MENTIONED ABOVE DO NOT HAVE ANY ELEVATION TAGS STATING | | | AT WHAT ELEVATION THE AISLE TOP OF SLABS FINISH. | | | THE DETAIL SHEET 0487_A6.11 DETAIL 07 STILL SHOW THE | | | VIP DUG OUT SEATS AT ELEVATION 99.0 FT. NGVD. SHEET | | | 0389_A2.411 JUST TO THE DETAIL TAG DETAIL 07/A6.11 | | | STILL SHOWS THE MAIN CONCURS AISLE AT ELEVATION 99 FT. | | | AND IN THE SAME DETAIL THE 6 HANDICAPPED WHEEL CHAIRS | | | ARE AT A FINISH SLAB OF 100 FT.NGVD. | | | | | | 4) PROVISO: BUILDER AT OWN RISK!!! SHEET 0390_A2-412. | | | THE PLANS INDICATE THE USE OF (3) INCLINED STAIRWAY | | | CHAIRLIFT. PLEASE PROVIDE DOCUMENTATION THAT THIS | | | PRODUCT WILL MEET THE REQUIREMENTS OF ASME A18.1. 2014 | | | FBC-ACCESSIBILITY CODE 410.1. | | | | | | 5) BUILDING PROVISO: SHEET 0540_A8-31. PLEASE PROVIDE | | | THE ELEVATOR MANUFACTURERS PRODUCT AND DATA AND SHOP | | | DRAWINGS WILL BE SUBMITTED TO THE DESIGN PROFESSIONAL | | | FOR REVIEW AND SHOP DRAWING STAMP OF APPROVAL BEFORE | | | BEING SUBMITTED TO THE CITY BUILDING DEPARTMENT FOR | | | REVIEW. 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 6) SHEET 0601_S2.611 MILB OBSERVATION TOWER PLANS NOT | | | IN THIS THIS OF DOCUMENTS, TO BE PERMITTED SEPARATELY. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-04-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-04-17 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-04-16 |
Time |
06:32 |
Sent To |
|
|
| Notes |
| 2016-04-17 12:03:15 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 16020418 / STADIUM, NATIONALS | | | CLUBHOUSE & PRACTICE FIELDS | | | W. P. B. PERMIT: 16020419/ ASTROS CLUBHOUSE | | | W. P. B. PERMIT: 16020417/ TEAM STORE & BAR | | | | | | ADD: 5444 N. HAVERHILL RD. | | | | | | CONT: HUNT CONSTRUCTION | | | | | | TEL: 561-568-8045 / MICHAEL SANCHEZ | | | | | | E-MAIL: [email protected] | | | | | | HCS ARCHITECT/ INTERIOR DESIGNER | | | ASSOCIATE ARCHITECT/ INTERIOR DESIGNER | | | GLIDDEN SPINA INTERIORS | | | STRUCTURAL ENGINEER | | | BLISS & NYITRAY, INC | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2ND REVIEW | | | DATE: SAT.-SUN. APRIL 16-17/2016 | | | ACTION: | | | | | | 1-3) COMPLIED . | | | | | | 4)BUILDING PROVISO: SHEET 0349_A2-120 & 0350_A2-121. | | | ROOF TOP MECHANICAL SCREENS. DETAILS 8 &9/ A6.21 & | | | 08/A7.21 . FINAL DIMENSIONS & LOCATION OF THE | | | MECHANICAL SCREEN TO BE DETERMINED BY THE LOCATION AND | | | SIZE OF THE MECHANICAL EQUIPMENT. | | | | | | 5-6) COMPLIED. | | | | | | 7) SHEET 0374_A2.217: | | | | | | 7A) BUILDING PROVISO: DELEGATE ENGINEER. ADDITIONAL | | | INFORMATION REQUIRED. 2014 FBC-B 410.4./ FBC-B 410.4, | | | LOADING REQUIREMENTS FOR THE RAISED DECK( TABLE | | | 1607.1), HANDRAIL , GUARDRAIL ASSEMBLY (1607.8) AND | | | STAIR(TABLE 1607.1). | | | | | | 7B) PROVISO: RESPONSE COMMENT: | | | 1ST ROUND OF COMMENTS. FOR BOTH PLATFORMS PLEASE SHOW | | | HOW COMPLIANCE WITH VERTICAL ACCESSIBILITY WILL BE | | | MET.2014 201.1.1 VERTICAL ACCESSIBILITY REQUIREMENTS. | | | | | | 7C ) BUILDING PROVISO: DELEGATE ENGINEER. THE INTERVIEW | | | ROOM 50/ 11709 ON THE RIGHT INDICATES A STAGE DETAIL ON | | | SHEET 07 / A2.712 . 107.2.1.3 ADDITIONAL INFORMATION | | | REQUIRED. 2014 FBC-B 410.4./ FBC-B 410.4, LOADING | | | REQUIREMENTS FOR THE RAISED DECK( TABLE 1607.1), | | | HANDRAIL , GUARDRAIL ASSEMBLY (1607.8) AND STAIR(TABLE | | | 1607.1). | | | | | | 7D-E) COMPLIED. | | | | | | 8-13) COMPLIED. | | | | | | 14) 0389_A2-411: | | | 14A) COMPLIED. SHEET A6.11 DETAIL 8 DOES SHOW THE | | | PLATFORM LIFT. NEW CONSTRUCTION ALLOWS THE USE OF | | | PLATFORM LIFTS UNDER THE 2014 FBC-ACCESSIBILITY | | | CODE206.7,2FOR ACCESSIBILITY AND DISPERSION AND LINE OF | | | SITE REQUIREMENTS OF 221 AND 802. | | | | | | 14B) SEMI-COMPLIED. THIS WILL BE A GENERAL COMMENT FOR | | | THE WHOLE OF THE STADIUM SEATING. PLEASE PROVIDE HOW | | | CODE COMPLIANCE WITH THE 2014 FBC-ACCESSIBILITY CODE | | | SECTIONS IS ACHIEVED: | | | 14B)(1) 221.2.1.1 SEMI COMPLIED. GENERAL SEATING. | | | WHEELCHAIR SPACES COMPLYING WITH 802.1 SHALL BE | | | PROVIDED IN ACCORDANCE WITH TABLE 221.2.1.1. | | | | | | 14B)(2) 2ND REQUEST. THERE SEEMS TO BE A DISCREPANCY | | | BETWEEN SHEET 0541_A9-01, 0389_A2-411 & 0487_A6-11 | | | DETAIL 5 & 0612_S4-31. THE (6) ACCESSIBLE SEATS IN BOWL | | | SECTION 01 THE VIP DUGOUT SEATS ARE NOT ACCESSIBLE ON | | | THE SHEETS LISTED ABOVE WITH EXCEPTION TO THE | | | ACCESSIBLE SEATING CHART FOUND ON 0541_A9-01. THE | | | DISPERSION OF SEATS WOULD APPEAR TO BE A LITTLE OFF AS | | | WELL AS THE COUNT.!!!! MARK UPS ON SHEET 0541_A9-01 | | | COMMENT FROM THE 1ST SET OF COMMENTS. 221.2.1.2 LUXURY | | | BOXES, CLUB BOXES, AND SUITES IN ARENAS, STADIUMS, AND | | | GRANDSTANDS. IN EACH LUXURY BOX, CLUB BOX, AND SUITE | | | WITHIN ARENAS, STADIUMS, AND GRANDSTANDS, WHEELCHAIR | | | SPACES COMPLYING WITH 802.1 SHALL BE PROVIDED IN | | | ACCORDANCE WITH TABLE 221.2.1.1. | | | | | | | | | 14B)(3) 221.2.1.3 OTHER BOXES. IN BOXES OTHER THAN | | | THOSE REQUIRED TO COMPLY WITH 221.2.1.2, THE TOTAL | | | NUMBER OF WHEELCHAIR SPACES REQUIRED SHALL BE | | | DETERMINED IN ACCORDANCE WITH TABLE 221.2.1.1. | | | WHEELCHAIR SPACES SHALL BE LOCATED IN NOT LESS THAN 20 | | | PERCENT OF ALL BOXES PROVIDED. WHEELCHAIR SPACES SHALL | | | COMPLY WITH 802.1. | | | | | | 14C) COMPLIED | | | | | | 14D) 2ND REQUEST. THE SEATING PLAN FOUND ON 0541_A9-01 | | | IN THE BERM AREA 02 SHOWS 11 ACCESSIBLE SEATS AT WHAT | | | APPEARS TO BE GRADE LEVEL. SHEET 0336_A2.02 & | | | 0385_A2-424 IN THE BOWL SECTION 4 DOES SHOW CONTOUR | | | LINES AND IT WOULD APPEAR WHERE THESE SEATS ARE LOCATED | | | THE BERM IS IN FRONT OF THEM, THE BALL GAME WOULD NOT | | | BE VISIBLE? 2014 FBC-ACCESS. CODE 802.2.LINE OF SIGHT. | | | COMMENT 1ST ROUND. ACCESS. CODE 221.5 LAWN SEATING. | | | LAWN SEATING AREAS AND EXTERIOR OVERFLOW SEATING AREAS, | | | WHERE FIXED SEATS ARE NOT PROVIDED, SHALL CONNECT TO AN | | | ACCESSIBLE ROUTE. | | | | | | 14E) SEMI- COMPLIED. ACCESS. CODE 221.6 STADIUMS, | | | ARENAS, AND GRANDSTANDS. WHEELCHAIR SPACES AND | | | COMPANION SEATS SHALL BE DISPERSED TO ALL LEVELS THAT | | | INCLUDE SEATING SERVED BY AN ACCESSIBLE ROUTE. | | | | | | 14F) SEMI-COMPLIED. ACCESS. CODE 221.7 SEATING | | | ENCIRCLING A FIELD OF PLAY OR PERFORMANCE. IN ASSEMBLY | | | AREAS THAT ARE REQUIRED TO HORIZONTALLY DISPERSE | | | WHEELCHAIR SPACES AND COMPANION SEATS BY SECTION | | | 221.2.3.1 AND THAT HAVE SEATING ENCIRCLING, IN WHOLE OR | | | IN PART, A FIELD OF PLAY OR PERFORMANCE, WHEELCHAIR | | | SPACES AND COMPANION SEATS SHALL BE DISPERSED AROUND | | | THAT FIELD OF PLAY OR PERFORMANCE AREA. | | | | | | 15) PROVISO: BUILDER AT OWN RISK!!! SHEET 0390_A2-412. | | | THE PLANS INDICATE THE USE OF (3) INCLINED STAIRWAY | | | CHAIRLIFT. PLEASE PROVIDE DOCUMENTATION THAT THIS | | | PRODUCT WILL MEET THE REQUIREMENTS OF ASME A18.1. 2014 | | | FBC-ACCESSIBILITY CODE 410.1. | | | | | | 16) COMPLIED, HYDROTHERAPY POOLS. | | | | | | 17) SHEET 0509_A7-11: PROVISO : HOW RAILINGS ARE TO BE | | | READ. SHEET A2.421- A2. 424. THE DRAWING ARE TO BE READ | | | FROM THE PLAN TO DETAIL. THEY SHOULD DETERMINE THE | | | RAILING REQUIREMENTS BY REVIEWWING THE PLANS, WHICH | | | PROVIDE A RAILING DESIGNATION, THEN REVIEIWING THE | | | RAILING SCHEDULE TO CONFIRM WHICH RAIL TYPE IS | | | REQUIRED. SHOP DRAWING ARE TO BE SUBMITTED TO THE | | | DESIGNER OF RECORD FOR APPROVAL WITH SHOP DRAWING STAMP | | | OF APPROVAL BEFORE BEING SUBMITTED TO THE CITY BUILDING | | | DEPARTMENT. | | | | | | 18) SHEET 0533_A8-01: | | | | | | 18A) COMPLIED. | | | | | | 18B) COMPLIED/ 2 ? INCHES BETWEEN WALL AND HANDRAIL | | | NFPA REQUIREMENT. | | | | | | 19-20) COMPLIED. | | | | | | 21) BUILDING PROVISO: SHEET 0540_A8-31. PLEASE PROVIDE | | | THE ELEVATOR MANUFACTURER?S PRODUCT AND DATA AND SHOP | | | DRAWINGS WILL BE SUBMITTED TO THE DESIGN PROFESSIONAL | | | FOR REVIEW AND SHOP DRAWING STAMP OF APPROVAL BEFORE | | | BEING SUBMITTED TO THE CITY BUILDING DEPARTMENT FOR | | | REVIEW. 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 22) SHEET 0601_S2.611 MILB OBSERVATION TOWER PLANS NOT | | | IN THIS THIS OF DOCUMENTS, TO BE PERMITTED SEPARATELY. | | | | | | 23) ELECTRONIC SIGNATURES MISSING ON SHEETS: | | | 0542-1_A9-111 | | | 0542-2_A9-115 | | | 0543_A9-121 | | | 0543_A9-122 | | | 054-2_A9-124 | | | 054-3_A9-125 | | | 0543-4_A9-126 | | | 0543-5_A9-128 | | | 0543-6_A9-129 | | | 0544_A9-132 | | | 0544-1_A9-134 | | | 0544-2_A9-135 | | | 0545_A9-217 | | | 0545-1_A9-218 | | | 0545-2_A9-219 | | | 0545-3_A9-227 | | | 0545-2_A9-228 | | | 0546_A9-312 | | | 0546-1_A9-313 | | | 0546-2_A9-314 | | | 0546-3_A9-324 | | | 0547_A10-110 | | | 0547-1_A10-111 | | | 0547-2_A10-115 | | | 0548_A10-121 | | | 0548-1_A10-122 | | | 0548-2_A10-124 | | | 0548-3_A10-125 | | | 0548-4_A10-126 | | | 0548-5_A10-128 | | | 0548-6_A10-129 | | | 0549_A10-132 | | | 0549-1_A10-134 | | | 0549-2_A10-125 | | | 0550_A10-217 | | | 0550-1_A10-217 | | | 0550-1_A10-218 | | | 0550-2_A10-219 | | | 0550-3_A10-227 | | | 0550-4_A10-228 | | | 0550-5_A10-312 | | | 0550-6_A10-313 | | | 0550-8_A10-324 | | | | | | 0598_S2-424 REUSED FROM STRUCTURE ONLY PERMIT CITY | | | STAMP APPLIED. | | | 0600_S2-512 REUSED FROM STRUCTURE ONLY PERMIT CITY | | | STAMP APPLIED. | | | 0614_S4-33 REUSED FROM STRUCTURE ONLY PERMIT CITY STAMP | | | APPLIED. | | | 0618_S6-12 REUSED FROM STRUCTURE ONLY PERMIT CITY STAMP | | | APPLIED. | | | 0622_S7-14 REUSED FROM STRUCTURE ONLY PERMIT CITY STAMP | | | APPLIED. | | | | | | | | | 24) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-03-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-03-04 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-02-23 |
Time |
10:50 |
Sent To |
|
|
| Notes |
| 2016-03-04 09:51:35 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 16020418 / STADIUM, NATIONALS | | | CLUBHOUSE & PRACTICE FIELDS | | | W. P. B. PERMIT: 16020419/ ASTROS CLUBHOUSE | | | W. P. B. PERMIT: 16020417/ TEAM STORE & BAR | | | | | | ADD: 5444 N. HAVERHILL RD. | | | CONT: HUNT CONSTRUCTION | | | TEL: 561-568-8045 / MICHAEL SANCHEZ | | | E-MAIL: [email protected] | | | | | | HCS ARCHITECT/ INTERIOR DESIGNER | | | ASSOCIATE ARCHITECT/ INTERIOR DESIGNER | | | GLIDDEN SPINA INTERIORS | | | | | | STRUCTURAL ENGINEER | | | BLISS & NYITRAY, INC | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 1ST REVIEW | | | DATE: | | | ACTION: DENIED | | | | | | 1) SHEET 0339_A2-110 STADIUM CLUBHOUSE LEVEL SECTOR A. | | | THIS COMMENT WILL STAND AS A COMMON COMMENT FOR ALL | | | SHEETS. SEE ROOMS 11029A, 11025 & 11032, ALL HAVE A | | | SIMILAR WALL DETAIL, WHAT APPEARS TO BE POSSIBLY A WALL | | | ACCESS PANEL TO GAIN ACCESS TO A WALL CLEAN OUT, PLEASE | | | PROVIDE ADDITIONAL INFORMATION ON THIS DETAIL. IT MAY | | | INTERFERE WITH THE CLEAR FLOOR SPACE FOR FIXTURES IF | | | NOT AN ACCESS COVER. 2014 FBC- ACCESSIBILITY CODE | | | 604.3.2 OVERLAP. SEE ROOM 11032. | | | | | | 2) SHEET 0340_A2-111 110 STADIUM CLUBHOUSE LEVEL SECTOR | | | B. THE DOOR 11103 PLEASE DIMENSION THE CLEAR FLOOR | | | SPACE TO THE RIGHT SIDE OF THE LATCH, IT MAY NOT MEET | | | THE MANEUVERING CLEARANCES REQUIRED BY THE 2014 | | | FBC-ACCESSIBILITY CODE 404.2.4 AND FIGURE 404.2.4.`(A). | | | REQUIRED 18 INCHES. | | | | | | 3) SHEETS 0345_A2-115 & 0355_A2-125 BOTH SHOW GATE G1 | | | THAT CAN BE LOCKED & BLOCKS AN ELEVATOR AND STAIRWAY. | | | THIS GATE IS NOT FOUND ON THE 3 SHEETS OF DOOR | | | SCHEDULE?S AND WOULD NEED TO COMPLY WITH EITHER | | | 2014 FBC-B 1008.1.10 PANIC HARDWARE OR 1008.2.1. PANIC | | | HARDWARE IS NOT REQUIRED ON GATES SURROUNDING STADIUMS | | | WHERE SUCH GATES ARE UNDER CONSTANT IMMEDIATE | | | SUPERVISION WHILE THE PUBLIC IS PRESENT, AND WHERE SAFE | | | DISPERSAL AREAS BASED ON 3 SQUARE FEET (0.28 M2) PER | | | OCCUPANT ARE LOCATED BETWEEN THE FENCE AND ENCLOSED | | | SPACE. SUCH REQUIRED SAFE DISPERSAL AREAS SHALL NOT BE | | | LOCATED LESS THAN 50 FEET (15 240 MM) FROM THE ENCLOSED | | | SPACE. SEE SECTION 1027.5 FOR MEANS OF EGRESS FROM SAFE | | | DISPERSAL AREAS. | | | | | | 4) SHEET 0349_A2-120 & 0350_A2-121. PROVISO: ROOF TOP | | | MECHANICAL SCREENS. DETAILS 8 &9/ A6.21 & 08/A7.21 . | | | FINAL DIMENSIONS & LOCATION OF THE MECHANICAL SCREEN TO | | | BE DETERMINED BY THE LOCATION AND SIZE OF THE | | | MECHANICAL EQUIPMENT. | | | | | | 5) SHEET 0351_AS-122 DRINKING FOUNTAIN. SHOWS A DETAIL | | | 06/0527-4_A7.65. THIS DETAIL SHOWS RAILINGS ON EACH | | | SIDE OF THE DRINKING FOUNTAIN, IT APPEARS TO TRY | | | COMPLYING WITH THE 2014 FBC-ACCESSIBILITY CODE | | | PROTRUDING OBJECTS SECTION 307.3. SEE NOTE: RAIL TYPE | | | XX, XX INCHES HIGH. | | | | | | 6) SHEET 0428_A3-58 DETAIL # 1 SHOWS A BAR AT A HEIGHT | | | OF 3 FT. 6 INCHES. PLEASE SHOW COMPLIANCE WITH THE: | | | 2014 FBC-ACCESSIBILITY CODE 226.1 WHERE DINING SURFACES | | | ARE PROVIDED FOR THE CONSUMPTION OF FOOD OR DRINK, AT | | | LEAST 5 PERCENT OF THE SEATING SPACES AND STANDING | | | SPACES AT THE DINING SURFACES SHALL COMPLY WITH 902. | | | | | | 2014 FBC-ACCESSIBILITY CODE 226.2 DISPERSION. DINING | | | SURFACES AND WORK SURFACES REQUIRED TO COMPLY WITH 902 | | | SHALL BE DISPERSED THROUGHOUT THE SPACE OR FACILITY | | | CONTAINING DINING SURFACES AND WORK SURFACES. | | | | | | 7) SHEET 0374_A2.217: | | | | | | 7A) THE INTERVIEW ROOM 50/ 11709 ON THE LEFT END OF THE | | | ROOM SHOWS A RAISED PLATFORM BUT THERE APPEARS TO BE A | | | DETAIL TAG THAT WAS BURIED INTO A WALL LINE DOES NOT | | | IDENTIFY WHERE TO LOCATE THE DETAIL. 107.2.1.3 | | | ADDITIONAL INFORMATION REQUIRED. 2014 FBC-B 410.4./ | | | FBC-B 410.4, LOADING REQUIREMENTS FOR THE RAISED DECK( | | | TABLE 1607.1), HANDRAIL , GUARDRAIL ASSEMBLY (1607.8) | | | AND STAIR(TABLE 1607.1). | | | | | | 7B) FOR BOTH PLATFORMS PLEASE SHOW HOW COMPLIANCE WITH | | | VERTICAL ACCESSIBILITY WILL BE MET.2014 201.1.1 | | | VERTICAL ACCESSIBILITY REQUIREMENTS. | | | | | | 7C ) THE INTERVIEW ROOM 50/ 11709 ON THE RIGHT | | | INDICATES A STAGE DETAIL ON SHEET 07 / A2.712 . | | | 107.2.1.3 ADDITIONAL INFORMATION REQUIRED. 2014 FBC-B | | | 410.4./ FBC-B 410.4, LOADING REQUIREMENTS FOR THE | | | RAISED DECK( TABLE 1607.1), HANDRAIL , GUARDRAIL | | | ASSEMBLY (1607.8) AND STAIR(TABLE 1607.1). | | | | | | 7D) DOOR JAMB 11713 IT APPEARS TO BE DEEPER ON THE | | | INSIDE THAN 8 INCHES WILL NEED TO COMPLY WITH 2014 | | | FBC-ACCESSIBILITY CODE 404.2.4.3. | | | | | | 7E) ASTROS LOBBY CLUBHOUSE STAIR DETAIL 01/A8.20 PLEASE | | | PROVIDE CODE COMPLIANCE WITH 2014 FBC-ACCESS. CODE | | | 307.4 & FIGURE 307.4. | | | | | | 8) SHEET 0375_A2-218. DOOR 11829B THIS DOOR IS A 3?-6? | | | DOOR, IT MAY OR MAY NOT PROVIDE THE 18 INCHES ON THE | | | PULL SIDE OF THE LATCH. 2014 FBC-ACCESSIBILITY CODE. | | | 404.2.4. MANEUVERING CLEARANCES. | | | | | | 9) 0381_A2-237 THE BRIDGE SHOW A CUT SECTION THROUGH, | | | SECTION0501_ A7.03. DETAIL 06. SHOWS AIPP BRIDGE | | | GUARDRAIL BY OTHERS. THIS PLAN DOES NOT GIVE THE | | | GUARDRAIL THE CODE DESIGN CRITERIA AS FOUND IN THE 2014 | | | FBC-B 1607.8.1. FOR THE OTHER DESIGNERS TO USE AS A | | | GUIDELINE. | | | | | | 10) SHEET 0384_A2-312. | | | 10A) MILB KITCHEN DOOR 11234 MAY NOT HAVE 18 INCHES FOR | | | MANEUVERING CLEARANCES PULL LATCH SIDE OF THE DOOR, NOT | | | DIMENSIONED AS TO 18 INCHES MINIMUM. 2014 FBC-ACCESS. | | | CODE 404.2.4.MANEUVERING CLEARANCES & FIGURE | | | 404.2.4.1.(A). | | | | | | 10B) DESIGNER OF RECORD SHOWS THE LAUNDRY ROOM 11211 IS | | | INDICATED 1 HR. RATED. NEITHER DOOR 11211 NOR 11211B | | | SHOW A DOOR RATING DOOR SCHEDULE 0411_A3-32. FBC-B | | | TABLE 716.5. NOT A SINGLE DOOR IS SHOWN TO BE FIRE | | | RATED. | | | | | | 11) SHEET 0385_A2-313. | | | 11A) THE DESIGNER OF RECORD INDICATES THE LAUNDRY ROOM | | | 11313 TO HAVE 1 HOUR FIRE RATING. THE DOOR SCHEDULE ON | | | 0411_A3-32 IS MISSING THE DOOR RATING. FBC-B TABLE | | | 716.5. | | | | | | 11B) PLEASE SEE MLB TRAVEL EQUIPMENT MANAGER ROOM 11309 | | | ENTRY DOOR THE WALL THICKNESS APPEARS TO BE | | | APPROXIMATELY 1 FOOT THICK. THE DOOR WILL NEED TO BE IN | | | COMPLIANCE WITH FBC-ACCESSIBILITY CODE 404.2.4.3 | | | RECESSED DOOR AND GATES. | | | | | | 12) SHEET 0386_A2-314: | | | 12A) EXAM ROOM 11425. ENTRY DOOR 11425 APPEARS TO BE IN | | | A WALL THICKER THAN 8 INCHES K1/R8, SHOW COMPLIANCE | | | WITH 2014 WITH FBC-ACCESSIBILITY CODE 404.2.4.3 | | | RECESSED DOOR AND GATES. | | | | | | 12B) DOOR 11237B WILL NEED TO SHOW COMPLIANCE WITH 2014 | | | FBC-ACCESSIBILITY 404.2.4.3 RECESSED DOOR AND GATES. | | | | | | 12C) THE ELECTRIC ROOM DOOR 11412 IS SHOWN TO BE IN A 1 | | | HOUR RATED WALL, SHOW COMPLIANCE WITH FBC-B TABLE | | | 716.5. | | | | | | 12D) THE ELECTRIC ROOM DOOR 11412 IS SHOWN TO BE IN A | | | WALL DEEPER THAN 8 INCHES K1/R8 WILL NEED TO COMPLY | | | WITH 2014 FBC-ACCESSIBILITY 404.2.4.3 RECESSED DOOR AND | | | GATES. | | | | | | 13) 0388_A2-324: | | | 13A) JUST TO THE LEFT OF DOOR 12412B THERE IS A 6INCH | | | DIMENSION AND ARROW TO A LINE BUT THERE IS NO REFERENCE | | | TO WHAT THE 6 INCHES IS INDICATING CHANGE IN GRADE? IF | | | SO PLEASE REVIEW 2014 1003.5 ELEVATION CHANGES. | | | | | | 13B) DOOR 12419 NOT DIMENSIONED IT APPEARS THAT IT MAY | | | NEED TO COMPLY WITH 2014 FBC-ACCESS. CODE 404.2.4 | | | MANEUVERING CLEARANCES, 18 INCHES LATCH SIDE OF THE | | | DOOR. | | | | | | 14) 0389_A2-411: | | | 14A) THERE IS NOMENCLATURE ON THE PLANS WITH A | | | DIRECTIONAL ARROW INDICATING A PLATFORM LIFT BUT THE | | | DIRECTIONAL ARROW APPEARS TO BE POINTING AT A STAIR OR | | | POSSIBLE ROOF? THE PROVIDED SECTION THROUGH THIS AREA | | | DETAIL 07/A6.11 SHOWS STAIRS NO ACCESSIBLE LIFT. | | | PROVIDE CODE COMPLIANCE. 2014 FBC202.1 & 410. | | | | | | 14B) THIS WILL BE A GENERAL COMMENT FOR THE WHOLE OF | | | THE STADIUM SEATING. PLEASE PROVIDE HOW CODE COMPLIANCE | | | WITH THE 2014 FBC-ACCESSIBILITY CODE SECTIONS IS | | | ACHIEVED: | | | 14B)(1) 221.2.1.1 GENERAL SEATING. WHEELCHAIR SPACES | | | COMPLYING WITH 802.1 SHALL BE PROVIDED IN ACCORDANCE | | | WITH TABLE 221.2.1.1. | | | | | | 14B)(2) 221.2.1.2 LUXURY BOXES, CLUB BOXES, AND SUITES | | | IN ARENAS, STADIUMS, AND GRANDSTANDS. IN EACH LUXURY | | | BOX, CLUB BOX, AND SUITE WITHIN ARENAS, STADIUMS, AND | | | GRANDSTANDS, WHEELCHAIR SPACES COMPLYING WITH 802.1 | | | SHALL BE PROVIDED IN ACCORDANCE WITH TABLE 221.2.1.1. | | | | | | 14B)(3) 221.2.1.3 OTHER BOXES. IN BOXES OTHER THAN | | | THOSE REQUIRED TO COMPLY WITH 221.2.1.2, THE TOTAL | | | NUMBER OF WHEELCHAIR SPACES REQUIRED SHALL BE | | | DETERMINED IN ACCORDANCE WITH TABLE 221.2.1.1. | | | WHEELCHAIR SPACES SHALL BE LOCATED IN NOT LESS THAN 20 | | | PERCENT OF ALL BOXES PROVIDED. WHEELCHAIR SPACES SHALL | | | COMPLY WITH 802.1. | | | | | | 14C) JUST TO THE RIGHT OF THE VIP SEATING THERE IS | | | ANOTHER SET OF STADIUM STYLE SEATS, THERE IS NO | | | ELEVATIONS PROVIDED FOR EACH TIER TO BE ABLE TO JUDGE | | | THE SIZE OF THE STEPS. | | | | | | 14D) ACCESS. CODE 221.5 LAWN SEATING. LAWN SEATING | | | AREAS AND EXTERIOR OVERFLOW SEATING AREAS, WHERE FIXED | | | SEATS ARE NOT PROVIDED, SHALL CONNECT TO AN ACCESSIBLE | | | ROUTE. | | | | | | 14E) ACCESS. CODE 221.6 STADIUMS, ARENAS, AND | | | GRANDSTANDS. WHEELCHAIR SPACES AND COMPANION SEATS | | | SHALL BE DISPERSED TO ALL LEVELS THAT INCLUDE SEATING | | | SERVED BY AN ACCESSIBLE ROUTE. | | | | | | 14F) ACCESS. CODE 221.7 SEATING ENCIRCLING A FIELD OF | | | PLAY OR PERFORMANCE. IN ASSEMBLY AREAS THAT ARE | | | REQUIRED TO HORIZONTALLY DISPERSE WHEELCHAIR SPACES AND | | | COMPANION SEATS BY SECTION 221.2.3.1 AND THAT HAVE | | | SEATING ENCIRCLING, IN WHOLE OR IN PART, A FIELD OF | | | PLAY OR PERFORMANCE, WHEELCHAIR SPACES AND COMPANION | | | SEATS SHALL BE DISPERSED AROUND THAT FIELD OF PLAY OR | | | PERFORMANCE AREA. | | | | | | 15) SHEET 0390_A2-412. THE PLANS INDICATE THE USE OF | | | (3) INCLINED STAIRWAY CHAIRLIFT. PLEASE PROVIDE | | | DOCUMENTATION THAT THIS PRODUCT WILL MEET THE | | | REQUIREMENTS OF ASME A18.1. 2014 FBC-ACCESSIBILITY CODE | | | 410.1. | | | | | | 16) SHEETS 0399_A2-613 & 0400_A2-614: | | | 16A) DETAIL 02/NATIONS. THE HYDROTHERAPY POOLS DO NOT | | | SHOW HANDRAILS/ GUARDRAILS REQUIRED BY THE 2014 FBC-B | | | 454.1.2.5.5. | | | | | | 16B) DETAIL 02 / NATIONALS. THE TREADMILL HYDROTHERAPY | | | POOL DOES NOT INDICATE ANY ACCESS POINTS INTO THE POOL | | | REQUIRED BY THE FBC-B 454.1.2.5. | | | | | | 16C) THERE IS NOT ENOUGH INFORMATION TO BE ABLE TO DO A | | | COMPLETE AND THOROUGH REVIEW OF THE HYDROTHERAPY POOL | | | TO BE ABLE TO COMPLY WITH THE SECTION 454.1 OF THE | | | FLORIDA BUILDING CODE. | | | THE EXCEPTIONS FOUND UNDER F.S. 514.0115 (5) DOES ALLOW | | | FOR A VARIANCE FROM THE FBC-B. THE DEPARTMENT MAY GRANT | | | VARIANCES FROM ANY RULE ADOPTED UNDER THIS CHAPTER | | | PURSUANT TO PROCEDURES ADOPTED BY DEPARTMENT RULE. THE | | | DEPARTMENT MAY ALSO GRANT, PURSUANT TO PROCEDURES | | | ADOPTED BY DEPARTMENT RULE, VARIANCES FROM THE | | | PROVISIONS OF THE FLORIDA BUILDING CODE SPECIFICALLY | | | PERTAINING TO PUBLIC SWIMMING POOLS AND BATHING PLACES | | | WHEN REQUESTED BY THE POOL OWNER OR THE POOL OWNER?S | | | REPRESENTATIVE TO RELIEVE HARDSHIP IN CASES INVOLVING | | | DEVIATIONS FROM THE FLORIDA BUILDING CODE PROVISIONS, | | | WHEN IT IS SHOWN THAT THE HARDSHIP WAS NOT CAUSED | | | INTENTIONALLY BY THE ACTION OF THE APPLICANT, WHERE NO | | | REASONABLE ALTERNATIVE EXISTS, AND THE HEALTH AND | | | SAFETY OF THE POOL PATRONS IS NOT AT RISK. | | | | | | 17) SHEET 0509_A7-11: RAIL TYPE SCHEDULE INDICATES | | | VARIOUS RAIL TYPES AND HEIGHTS. IT WOULD HELP IS THERE | | | WAS A COLUMN THAT WOULD GIVE THE SHEET NUMBER WE COULD | | | LOCATE THE USE OF EACH RAIL TYPE SINCE THEY ALL ARE NOT | | | 42 INCHES IN HEIGHT. 2014 FBC-B 1013.3 HEIGHT. REQUIRED | | | GUARDS SHALL NOT BE LESS THAN 42 INCHES (1067 MM) HIGH, | | | MEASURED VERTICALLY. | | | | | | 18) SHEET 0533_A8-01: | | | 18A) DETAILS 2 , 3 & 4 ALL INDICATE STEEL STRINGER | | | STAIRS WITH WHAT APPEARS TO BE OPEN STAIRS. PLEASE SHOW | | | COMPLIANCE WITH: | | | 2014 FBC-B 1009.7.5.3 SOLID RISERS. | | | 2014 FBC-ACCESS. CODE 504.3. OPEN RISERS ARE NOT | | | PERMITTED. | | | | | | 18B) DETAILS 06 & 12 BOTH SHOW THE HANDRAILS 2 ? INCHES | | | FROM THE WALL. THE 2014 FBC-B SECTION 1012.7 CLEARANCE | | | INDICATES A MINIMUM OF 1 ? INCHES FROM A WALL OR OTHER | | | SURFACES. THE 2014 FBC-ACCESSIBILITY CODE SECTION 505.5 | | | CLEARANCE INDICATES THE 1 ? INCH MEASUREMENT AS AN | | | ABSOLUTE, NOTE THIS IS NOT A FLORIDA SPECIFIC GRAY BOX | | | BUT FEDERAL ADA REQUIREMENT. THE REASONING BEHIND THIS | | | REQUIREMENT IS A PERSON WITH ACCESSIBILITY ISSUES MAY | | | SLIP AND FALL AND GET THEIR ARM IS PINCHED HIGHER UP | | | THE ARM AND CAN BREAK THEIR ARM, AT 1 ? INCHES IT IS | | | MORE LIKELY THEY WILL GET THEIR WRIST PINCHED WHICH HAS | | | A MOVABLE JOINT. | | | THIS OCCURRENCE WOULD BE WHERE THERE IS NO VERTICAL | | | ACCESSIBILITY BY ELEVATOR OR BY A PLATFORM LIFT. | | | OTHERWISE SIGNAGE SHOULD BE PLACED WHERE THE ACCESSIBLE | | | STAIRS ARE LOCATED. | | | | | | 19) SHEET 035_A8-10 STADIUM STAIR PLAN AND DETAILS DOES | | | NOT PROVIDE WHAT THE MINIMUM DESIGN CRITERIA UNIFORM | | | LIVE LOADS 2014 FBC-B TABLE 1607.1. | | | | | | 20) SHEET 0538_A8-21 SECTIONS 01 & 04. PROVIDE CODE | | | COMPLIANCE WITH THE 2014 FBC-B: | | | 3011.1 ELECTROLYSIS PROTECTION FOR UNDERGROUND | | | HYDRAULIC ELEVATOR CYLINDERS. | | | ALL NEWLY INSTALLED UNDERGROUND HYDRAULIC PRESSURE | | | CYLINDERS SHALL BE ENCASED IN OUTER PLASTIC CONTAINMENT | | | TO MINIMIZE ELECTROLYTIC CORROSION BETWEEN THE METAL | | | CYLINDER AND GROUND CATHODE. | | | 3011.1.1 THE PLASTIC CASING SHALL BE CAPPED AT THE | | | BOTTOM, AND ALL JOINTS MUST BE SOLVENT OR HEAT WELDED | | | TO ENSURE WATER TIGHTNESS. | | | | | | 21) SHEET 0540_A8-31. PLEASE PROVIDE MANUFACTURES | | | SPECIFICATIONS ON THE TYPE OF ELEVATOR WILL BE IN THIS | | | INSTALLATION. 107.2.1.3 ADDITIONAL INFORMATION IS | | | REQUIRED. | | | | | | 22) SHEET 0601_S2.611 MILB OBSERVATION TOWER PLANS NOT | | | IN THIS THIS OF DOCUMENTS, TO BE PERMITTED SEPARATELY. | | | | | | 23) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION | | | DEVELOPMENT SERVICES DEPARTMENT | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
N |
Date |
2016-06-16 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-06-16 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-06-16 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2016-06-16 09:42:46 | INITIAL ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 NEC | | | COMMENTS: | | | | | | 1. PLEASE NOTE THAT ALL L/V SYSTEMS ARE TO BE PERMITTED | | | SEPARATELY. FBC 107.3.5 | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2016-05-19 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-05-19 |
Time |
15:47 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-05-19 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2016-05-19 15:47:47 | ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 | | | COMMENTS: | | | | | | 1. PROVISO- EMERGENCY LIGHTING AS ADDRESSED BY EOR | | | SUBJECT TO FIELD INSPECTOR APPROVAL | | | | | | | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2016-04-22 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-04-22 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-04-15 |
Time |
08:25 |
Sent To |
|
|
| Notes |
| 2016-04-22 11:00:26 | 2ND ELECTRICAL REVIEW COMMENTS | | | REVIEWED FOR COMPLIANCE WITH: | | | 5TH EDITION OF THE FBC 2014 & NFPA 70 (NEC) 2011 | | | EDITION | | | | | | WITH THE EXCEPTION OF THE MISSING ILLUMINATION ISSUES, | | | THE BELOW MENTIONED ITEMS CAN BE EASILY ADDRESSED WITH | | | THE PROPER NOTES. THEREFORE A NARRATIVE ADDRESSING THE | | | ISSUES CAN BE ACCEPTED AND PLANS ISSUED WITH A PROVISO | | | RELATING THERETO. | | | | | | AS USUAL, IF DURING THE PLAN REVIEW I MISUNDERSTOOD A | | | SHEET?S INTENTION AND THE COMMENTS ISSUED ARE | | | NON-APPLICABLE PLEASE CORRECT ME AND EXPLAIN. | | | | | | CORRECTIONS REQUIRED: | | | SHEET E1.00-2, E2.111, E3.127, UPLOAD CORRUPTED, | | | SHEET E2.110 | | | 1. PER NEC 680.62 HYDRO TUB OUTLETS SHALL BE GFI | | | PROTECTED. | | | 2. NEC 210.8(B)(7) LOCKER ROOM OUTLETS WITH AN | | | ASSOCIATED SHOWER FACILITY SHALL BE GFCI PROTECTED. | | | SHEET E2.119, E2.112, E2.113, E2.114, E2.117, | | | 1. NEC 210.8(B)(7) LOCKER ROOM OUTLETS WITH AN | | | ASSOCIATED SHOWER FACILITY SHALL BE GFCI PROTECTED. | | | SHEET E2.127 | | | 1. NEC 210.63 REQUIRES A GFCI PROTECTED OUTLET WITH 25? | | | OF EQUIPMENT. AD.0-AE.0/A04.5-A05 | | | SHEET E2.129 | | | 1. EXPLAIN 208/1PH | | | 2. NEC 210.63 REQUIRES A GFCI PROTECTED OUTLET WITH 25? | | | OF EQUIPMENT. OUTLET SHOWN ON PLANS IS OUTSIDE THE | | | ROOM. A08.3-A08.9/AD | | | 3. SAME APPLIES FOR ADJACENT AREA. AD-AB.5/A07.5-A08 | | | SHEET E2.134, E2.132, | | | 1. TYPICAL PADDLE FAN NOTE ADDED TO PLANS. | | | SHEET E2.411, E2.128, E2.126, E2.125, E2.122, | | | 1. EXPLAIN 208/1 PH | | | 2. PANEL SCHEDULE ON SHEET E5.01 DOES NOT INDICATE ANY | | | LOADS ON CKTS 76,9 OF LP-NB-1 | | | SHEET E2.413, E2.412, | | | 1. MISSING THE WEATHER-RESISTANT NOTE ADDED TO ALL | | | OTHER SHEETS. | | | SHEET E3.112, E3.113, E3.114, E3.115, E3.117, E3.118, | | | E3.119, E3.124, E30125, E3.126, E3.128, E3.134, | | | 1. ADDITIONAL EMERGENCY LIGHTING REQUIRED IN ROOMS, | | | 1240, 1235, (SHOWER AND TOILET AREAS OF 1204, 1207), | | | 1211, 1214, 1301, 1310, 1313, 1406, 1413, 1414, 1417, | | | 1419, 1506, 1508, 1512, 1713, 1706, 1708, 1707, 1801, | | | 1831, 1832, 1820, 1901, 1916, 1909, 2428, 2517, 2603, | | | 2607, 2608, 2605, 2616, AREA OF SO5-SO6/SC.5-SB.6, | | | 2811, 2509, | | | 2. LIGHTING CONTROL MISSING IN ROOMS 1205, 1206, 1208, | | | 1321, 1322, 1429, 1417, 1419, 1710, AREA OF | | | SO5-SO6/SC.5-SB.6, 2811, JAN CLOSET BETWEEN 3410 & | | | 3413, 3407, NO3-NO3.5/NC-ND, | | | 3. ILLUMINATION AND CONTROL MISSING IN ROOM 1806, 1907, | | | 1908, 2504, 2508, 2509, CORRIDOR SH-SF/S13.25-S13.5, | | | 3421, | | | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | | RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER | | | (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER | | | WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD | | | CITY RE-SUBMITTAL FORM. CLOUDING THE CHANGES WILL BE | | | GREATLY APPRECIATED. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU, | | | MIKE ALBARRAN | | | ELECTRICAL PLANS EXAMINER | | | PH: 561-805-6746 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2016-03-10 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-03-10 |
Time |
18:56 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-03-07 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2016-03-10 18:57:59 | 1ST ELECTRICAL REVIEW NOTES FOR REVISION #: | | | 16020418, 16020417, 16020419 | | | REVIEWED FOR COMPLIANCE WITH: | | | 5TH EDITION FBC 2014 | | | NFPA 70 2011 (NEC) | | | | | | CORRECTIONS REQUIRED: | | | SHEET E0.01 | | | 0. INCLUDE ON THE SHEET DRAWINGS THE DRAWING SCALE | | | BEING USED. CITY OF WEST PALM BEACH AMENDMENTS LIMITS | | | DRAWINGS TO NO LESS THAN 1/8? SCALE. | | | 1. THIS SYMBOL MAY INTERFERE OR BE CONFUSED WITH THAT | | | OF THE EXIT LIGHTS. | | | 2. NEC 406.9(B), WEATHER-PROOF RECEPTACLES IN ?WET | | | LOCATIONS? SHALL BE LISTED ?WEATHER-RESISTANT?. | | | 3. INDICATE ON THE LIGHTING LEGEND WHICH OF THE | | | FIXTURES WILL HAVE A BATTERY PACK OR BE TIED INTO AN | | | EMERGENCY LIGHTING CIRCUIT. | | | SHEET E0.02 | | | 1. INDICATE ON THE FIXTURE SCHEDULE WHICH OF THE | | | FIXTURES WILL HAVE BATTERY BALLAST. | | | SHEET E2.110, E2.111, E2.112, E2.113, E2.114, E2.115, | | | E2.117, E2.118, E2.119, E2.121, E2.122, E2.123, E2.124, | | | E2.125, E2.126, E2.127, E2.128, E2.129, E2.132, E2.134, | | | E2.135, E2.136, E2.137, E2.145, E2.411, E2.412, E2.413, | | | 1. NEC 210.8(B)(7) RECEPTACLES IN LOCKER ROOMS WITH | | | ASSOCIATED SHOWERS SHALL BE GFCI PROTECTED. | | | 2. NEC 408.9(B) .....AND BE LISTED "WEATHER-RESISTANT" | | | "WR". | | | SHEET E2.113 | | | 1. IDENTIFY OR CORRECT THE ?NG? FOLLOWING THE NUMERIC | | | RATING IN THE NUMBERED NOTES. | | | SHEETS E2.116, E2.130, E2131, E2.140, E2.141, E2.142, | | | E2.143, E2.144, E3.116, | | | 1. THESE SHEETS ARE MISSING. IS THIS PAGE INTENTIONALLY | | | SKIPPED OR IS IT AN ERROR. | | | SHEET E2.126 STORE AREA | | | 1. NEC 210.62 SHOW WINDOW REQUIREMENT, THERE SHALL BE A | | | 120 VAC OUTLET WITH 18? OF THE TOP OF EVERY SHOW WINDOW | | | FOR EVERY 12? OF SHOW WINDOW OR MAJOR PORTION THEREOF. | | | 2. NEC 600.5 SIGN OUTLET REQUIREMENT. THERE SHALL BE A | | | DEDICATED SIGN OUTLET AT EVERY PEDESTRIAN ENTRY DOOR. | | | SHEET E3.110, E3.111, | | | 1. IN ADDITION TO THE MISSING EMERGENCY LIGHTING, YOU | | | SHALL SHOW COMPLIANCE WITH FBC-EC405 FOR LIGHT | | | REDUCTION. | | | 2. ACCORDING TO THE FIXTURE SCHEDULE THE EXIT LIGHTS DO | | | NOT HAVE BATTERY BACK UP. (TYPICAL) | | | SHEET E3.513 | | | 1. EXHAUST FANS REQUIRED FOR THE TOILET ROOMS. | | | | | | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | | RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER | | | (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER | | | WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD | | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID | | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | | GREATLY APPRECIATED. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU, | | | MIKE ALBARRAN | | | ELECTRICAL PLANS EXAMINER | | | PH: 561-805-6746 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-03-03 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-03-03 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-03-03 |
Time |
12:00 |
Sent To |
|
|
| Notes |
| 2016-03-03 14:10:17 | THERE IS A PROBLEM WITH THE PLANS AND/OR PROJECTDOX | | | MAKING THE PLANS ILLEGIBLE. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
P |
Date |
2016-04-20 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2016-04-20 |
Time |
|
Rev Time |
0.50 |
| Received By |
mgonzale |
Date |
2016-04-20 |
Time |
|
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2016-04-19 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2016-04-19 |
Time |
10:23 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2016-04-19 |
Time |
10:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2016-03-09 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2016-03-09 |
Time |
17:05 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2016-03-09 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2016-03-09 11:01:15 | 5444 NORTH HAVERHILL ROAD | | | PERMIT #16020418 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | NOTE: UNLESS NOTED OTHERWISE, ALL FIRE/LIFE SAFETY | | | REVIEW COMMENTS REFERENCE NFPA 101-THE LIFE SAFETY CODE | | | (2012 EDITION WITH FLORIDA AMENDMENTS.) | | | | | | SHEET LS1.02: A FIRE IN CORRIDOR #11237 HAS THE | | | POTENTIAL TO BLOCK BOTH EXITS FROM COACH'S LOCKER | | | #11415. PER SECTION 7.5.1.3.1 WHERE MORE THAN ONE EXIT, | | | EXIT ACCESS, OR EXIT DISCHARGE IS REQUIRED FROM A | | | BUILDING OR PORTION THEREOF, SUCH EXITS, EXIT ACCESSES, | | | OR EXIT DISCHARGES SHALL BE REMOTELY LOCATED FROM EACH | | | OTHER AND BE ARRANGED TO MINIMIZE THE POSSIBILITY THAT | | | MORE THAN | | | ONE HAS THE POTENTIAL TO BE BLOCKED BY ANY ONE FIRE OR | | | OTHER EMERGENCY CONDITION. | | | | | | SHEET A2.227: 1ST FLOOR LOBBY #11711 IS OPEN TO THE | | | SECOND FLOOR RECEPTION #12704. PER SECTION 8.6.9.2 | | | UNENCLOSED VERTICAL OPENINGS CREATED BY CONVENIENCE | | | STAIRWAYS SHALL BE PERMITTED AS FOLLOWS: 1) THE | | | CONVENIENCE STAIR OPENING SHALL NOT SERVE AS A REQUIRED | | | MEANS OF EGRESS 2) THE CONVENIENCE STAIR OPENING SHALL | | | BE PROTECTED IN ACCORDANCE WITH THE METHOD DETAILED FOR | | | THE PROTECTION OF VERTICAL OPENINGS IN NFPA 13, | | | STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS. | | | | | | SHEET A2.324 1ST FLOOR LOBBY #11408 IS OPEN TO THE | | | SECOND FLOOR CORRIDOR #12412B. PER SECTION 8.6.9.2 | | | UNENCLOSED VERTICAL OPENINGS CREATED BY CONVENIENCE | | | STAIRWAYS SHALL BE PERMITTED AS FOLLOWS: 1) THE | | | CONVENIENCE STAIR OPENING SHALL NOT SERVE AS A REQUIRED | | | MEANS OF EGRESS 2) THE CONVENIENCE STAIR OPENING SHALL | | | BE PROTECTED IN ACCORDANCE WITH THE METHOD DETAILED FOR | | | THE PROTECTION OF VERTICAL OPENINGS IN NFPA 13, | | | STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS. | | | | | | SHEET E1.00: PROVIDE AMBULANCE/RESCUE VEHICLE120V SHORE | | | POWER RECHARGING STATION ALONG FIRE LANE NEAR SITE PLAN | | | MARKER #8. | | | | | | SHEET E2.411: PROVIDE AMBULANCE/RESCUE VEHICLE120V | | | SHORE POWER RECHARGING STATION IN VEHICLE ENTRANCE | | | TUNNEL ADJACENT TO THE BULLPEN. | | | | | | IN GENERAL THE EMERGENCY LIGHTING AND EXIT SIGN | | | PLACEMENT IS INCONSISTENT. FOR EXAMPLE: | | | SHEET E3.110: COULD ONLY LOCATE 1 EMERGENCY LIGHT | | | FIXTURE. | | | SHEET E3.111: CORRIDOR #11130 INDICATES A LIGHT FIXTURE | | | F7 WITH AN "EM" DESIGNATION. THIS APPEARS TO BE | | | POSSIBLY EMERGENCY LIGHTING BUT THE EM ABBREVIATION IS | | | NOT FOUND OR DESCRIBED ON SHEET E0.01. ALSO CORRIDOR | | | #11130 HAS AN EXIT SIGN LEADING OCCUPANTS THROUGH A | | | HIGHER HAZARD (MAINT. SHOP) WHICH IS NOT PERMITTED. | | | SHEET E3.111: NO EMERGENCY LIGHTING ON MEZZANINE AND | | | ONLY 1 EXIT SIGN PROVIDED IN MAINTENANCE SHOP #11125. | | | SHEET E3.118: NO EXIT SIGNS IN LOCKER ROOM #11718. | | | SHEET E3.119: NO EXIT SIGNS OR EMERGENCY LIGHTS IN MLB | | | EQUIP. #11917; OTHER LARGE ROOMS SIMILAR TO THIS ROOM | | | HAVE BOTH. | | | | | | FIRE ALARM PLANS DO NOT INDICATE A SCALE. | | | | | | FA2.110: DOES NOT APPEAR TO BE SUFFICIENT VISUAL | | | COVERAGE IN UMPIRE SHOWER #11031. | | | | | | FA2.113: NO NOTIFICATION PROVIDED IN SAUNAS. INADEQUATE | | | COVERAGE PROVIDED FOR EAST PORTION OF WEIGHTS #11318. | | | NO NOTIFICATION CONFERENCE #11301. | | | | | | FA2.118: NO NOTIFICATION PROVIDED IN EAST PORTION OF | | | KITCHEN. NO PULL STATION PROVIDED AT GYM STAIR EXIT | | | DOOR. | | | | | | FA2.122: NO NOTIFICATION PROVIDED IN EAST PORTION OF | | | KITCHEN. | | | | | | FA2.124: NO NOTIFICATION IN NORTH ROOM OF COMMISSARY | | | #12405 AND WEST ROOM OF CONCESSION #12404. | | | | | | FA2.127: NO PULL STATION AT EXIT DOOR. | | | | | | FA2.128: NO PULL STATION AT EXIT DOOR. | | | | | | FA2.134: NO NOTIFICATION IN WOMENS' RESTROOM #13414. | | | | | | SIGNAGE: PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT | | | DOORS WITH EXIT SIGNS. | | | | | | SIGNAGE: EVERY ASSEMBLY OCCUPANCY ROOM NOT HAVING FIXED | | | SEATS SHALL HAVE THE OCCUPANT LOAD OF THE ROOM POSTED | | | IN A CONSPICUOUS PLACE NEAR THE MAIN EXIT FROM THE | | | ROOM. SIGNS SHALL BE DURABLE AND INDICATE THE NUMBER OF | | | OCCUPANTS PERMITTED FOR EACH ROOM. | | | | | | DISCLAIMER: REVIEW AND APPROVAL BY THE AHJ SHALL NOT | | | RELIEVE THE OWNER, CONTRACTOR, ETC. OF THE | | | RESPONSIBILITY OF COMPLIANCE WITH CODE (NFPA 1, SECTION | | | 1.14.4). FBC SECTION 105.4.1 PERMIT INTENT: A PERMIT | | | ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED | | | WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, | | | ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE | | | TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT | | | THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A | | | CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR | | | VIOLATIONS OF THIS CODE. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2016-03-03 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2016-03-03 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2016-02-23 |
Time |
12:08 |
Sent To |
|
|
| Notes |
| 2016-02-24 16:00:49 | 5444 NORTH HAVERHILL ROAD | | | PERMIT #16020418 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | NOTE: UNLESS NOTED OTHERWISE, ALL FIRE/LIFE SAFETY | | | REVIEW COMMENTS REFERENCE NFPA 101-THE LIFE SAFETY CODE | | | (2012 EDITION WITH FLORIDA AMENDMENTS.) | | | | | | SHEET LS1.02: A FIRE IN CORRIDOR #11237 HAS THE | | | POTENTIAL TO BLOCK BOTH EXITS FROM COACH'S LOCKER | | | #11415. PER SECTION 7.5.1.3.1 WHERE MORE THAN ONE EXIT, | | | EXIT ACCESS, OR EXIT DISCHARGE IS REQUIRED FROM A | | | BUILDING OR PORTION THEREOF, SUCH EXITS, EXIT ACCESSES, | | | OR EXIT DISCHARGES SHALL BE REMOTELY LOCATED FROM EACH | | | OTHER AND BE ARRANGED TO MINIMIZE THE POSSIBILITY THAT | | | MORE THAN | | | ONE HAS THE POTENTIAL TO BE BLOCKED BY ANY ONE FIRE OR | | | OTHER EMERGENCY CONDITION. | | | | | | SHEET A2.227: 1ST FLOOR LOBBY #11711 IS OPEN TO THE | | | SECOND FLOOR RECEPTION #12704. PER SECTION 8.6.9.2 | | | UNENCLOSED VERTICAL OPENINGS CREATED BY CONVENIENCE | | | STAIRWAYS SHALL BE PERMITTED AS FOLLOWS: 1) THE | | | CONVENIENCE STAIR OPENING SHALL NOT SERVE AS A REQUIRED | | | MEANS OF EGRESS 2) THE CONVENIENCE STAIR OPENING SHALL | | | BE PROTECTED IN ACCORDANCE WITH THE METHOD DETAILED FOR | | | THE PROTECTION OF VERTICAL OPENINGS IN NFPA 13, | | | STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS. | | | | | | SHEET A2.324 1ST FLOOR LOBBY #11408 IS OPEN TO THE | | | SECOND FLOOR CORRIDOR #12412B. PER SECTION 8.6.9.2 | | | UNENCLOSED VERTICAL OPENINGS CREATED BY CONVENIENCE | | | STAIRWAYS SHALL BE PERMITTED AS FOLLOWS: 1) THE | | | CONVENIENCE STAIR OPENING SHALL NOT SERVE AS A REQUIRED | | | MEANS OF EGRESS 2) THE CONVENIENCE STAIR OPENING SHALL | | | BE PROTECTED IN ACCORDANCE WITH THE METHOD DETAILED FOR | | | THE PROTECTION OF VERTICAL OPENINGS IN NFPA 13, | | | STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS. | | | | | | ALL OF THE E2 AND E3 SERIES ELECTRICAL DRAWINGS ARE | | | CORRUPT FILES OR THE PLANS HAVE NOT BEEN COMPLETED. | | | | | | SHEET E5-04 FIRE ALARM RISER: FILE IS CORRUPT OR PLAN | | | HAS NOT BEEN COMPLETED. | | | | | | ALL OF THE FA2 SERIES FIRE ALARM DRAWINGS ARE CORRUPT | | | FILES OR THE PLANS HAVE NOT BEEN COMPLETED. | | | | | | SIGNAGE: PROVIDE TACTILE SIGNAGE AT ALL REQUIRED EXIT | | | DOORS WITH EXIT SIGNS. | | | | | | SIGNAGE: EVERY ASSEMBLY OCCUPANCY ROOM NOT HAVING FIXED | | | SEATS SHALL HAVE THE OCCUPANT LOAD OF THE ROOM POSTED | | | IN A CONSPICUOUS PLACE NEAR THE MAIN EXIT FROM THE | | | ROOM. SIGNS SHALL BE DURABLE AND INDICATE THE NUMBER OF | | | OCCUPANTS PERMITTED FOR EACH ROOM. | | | | | | DISCLAIMER: REVIEW AND APPROVAL BY THE AHJ SHALL NOT | | | RELIEVE THE OWNER, CONTRACTOR, ETC. OF THE | | | RESPONSIBILITY OF COMPLIANCE WITH CODE (NFPA 1, SECTION | | | 1.14.4). FBC SECTION 105.4.1 PERMIT INTENT: A PERMIT | | | ISSUED SHALL BE CONSTRUED TO BE A LICENSE TO PROCEED | | | WITH THE WORK AND NOT AS AUTHORITY TO VIOLATE, CANCEL, | | | ALTER OR SET ASIDE ANY OF THE PROVISIONS OF THE | | | TECHNICAL CODES, NOR SHALL ISSUANCE OF A PERMIT PREVENT | | | THE BUILDING OFFICIAL FROM THEREAFTER REQUIRING A | | | CORRECTION OF ERRORS IN PLANS, CONSTRUCTION OR | | | VIOLATIONS OF THIS CODE. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | (561) 805-6730 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2016-05-12 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-05-12 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-05-12 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2016-05-12 10:45:39 | THE GAS SHALL BE DONE UNDER A SEPARATE PERMIT. PLANS | | | AND SPECIFICATIONS SHALL BE SUBMITTED FOR REVIEW. TKL. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2016-04-28 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-04-28 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-04-27 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2016-04-27 15:02:26 | 1) THE RESPONSE FROM WSP FOR COMMENT #32 DOES NOT | | | SATISFY THE COMMENT. SUBMIT A DETAIL SHOWING THE TYPE, | | | LOCATION SIZE AND TERMINATION OF ALL GAS VENTS FROM | | | EQUIPMENT AND APPLIANCES THAT ARE REQUIRED TO BE VENTED | | | TO THE EXTERIOR.2014 FGC SECS.502 THRU 505. THE REVIEW | | | COMMENT WAS NOT SPECIFIC AS TO THE TYPE OF VENT | | | INFORMATION THAT WAS BEING REQUESTED. | | | 2) SUBMIT A GAS EQUIPMENT SCHEDULE LISTING EACH GAS | | | APPLIANCE/ PIECE OF EQUIPMENT, THE BTU VALUE, THE TAG / | | | ITEM NUMBER AND THE PIPE SIZE FOR THE APPLIANCE | | | /EQUIPMENT. I HAVE ALREADY REVIEWED THE K DRAWINGS. | | | 3) SHT. P5.401 & P5.401.3 - THE RISER SHOWS THE TOTAL | | | BTU LOAD ON THE MAIN AND AT THE METER AS 9258 MBH. | | | AFTER THE TWO GWH-2 WATER HEATERS THE LOAD IS REDUCED | | | TO 5358 MBH. PLEASE CLARIFY AS TO HOW 9258 MBH MINUS | | | 1980 MBH EQUALS 5358 MBH. MY CALCULATION COMES TO 7278 | | | MBH .THIS LINE IS UNDERSIZED AND NEEDS TO BE 4 INCHES | | | IN SIZE. THE ENTIRE LINE SHALL BE CHECKED FOR PROPER | | | SIZING IN ACCORDANCE WITH 2014 FGC TABLE 402.4 (5). | | | CLARIFY. | | | 4) A LISTED SHUTOFF VALVE SHALL BE INSTALLED | | | IMMEDIATELY AHEAD OF EACH MEDIUM PRESSURE REGULATOR. | | | 2014 FGC SEC.409.4. | | | 5) SHT. P5.401 & P5.401.1 - THE 1 1/4 INCH LINE TO | | | APPLIANCES #1047 & #1048 IS UNDERSIZED. THE MAXIMUM BTU | | | LOAD ON A 1 INCH PIPE AT 30 FT. DEVELOPED LENGTH IS 583 | | | MBH PER FGC TABLE 402.4 (1). | | | 6) SHT. P5.401.1 - SIZE THE GAS LINE TO GWH-3 AND SHOW | | | THE BTU LOAD ON THE RISER. | | | 7) SHT. P5.401.2 - SIZE THE PIPE TO GWH-3 DOWNSTREAM OF | | | THE MP REGULATOR. THE LINE SHALL BE A MINIMUM OF 1 INCH | | | PER FGC TABLE 402.4 (1).THE MEDIUM PRESSURE SIDE SHALL | | | ALSO BE 1 INCH PER TABLE 403.4 (5). | | | 8) SHT. P5.402.1 - THE 3/4 INCH LINE TO ITEM #243 IS | | | UNDERSIZED.THE MAXIMUM MBH ON A 3/4 INCH LINE AT 20 FT. | | | IS 188 MBH. THE 1 INCH LINE CARRYING 440 MBH IS | | | UNDERSIZED. THE MAXIMUM BTU LOAD ON A 1 INCH LINE AT 20 | | | FT. IS 353 MBH PER TABLE 402.4 (1) OF FGC. | | | 9) SHT. P5.402.1 - SIZE THE LINES TO UNITS MUA-A-2-2 | | | AND ERU-A-3-1 DOWNSTREAM OF THE MP REGULATOR. THE SIZE | | | OF THE LINE TO ERU-A-3-1 SHALL BE A MINIMUM OF 1 INCH. | | | FGC TABLE 402.4 (1). | | | 10) SIZE ALL SECTIONS OF PIPING DOWNSTREAM OF ALL MP | | | REGULATORS. | | | 11) SHT. P5.402.1- THE LOW PRESSURE LINE SUPPLYING 440 | | | MBH TO ITEMS # 243, 246 & 247 IS UNDERSIZED. THE | | | MINIMUM SIZE PIPE SHALL BE 1 1/4 INCHES. FGC TABLE | | | 402.4 (1). | | | 12) SHT. P5.402.1 - THE 3/4 INCH LOW PRESSURE LINE TO | | | ITEM # 243 IS UNDERSIZED. THE MINIMUM SIZE SHALL BE 1 | | | INCH PER FGC TABLE 402.4.(1). | | | 13) SHT. P5.402.2 - SIZE THE LOW PRESSURE LINE | | | DOWNSTREAM OF THE MP REGULATOR TO UNIT MUA-A-2-1. | | | 14) SHT. P5.402.2 - THE RISER SHOWS A 3/4 INCH LOW | | | PRESSURE LINE TO ITEM #L2 CARRYING 350 MBH. THE MAXIMUM | | | MBH ON A 3/4 INCH LINE AT 20 FT. IS 188 MBH. THE | | | MINIMUM SIZE OF THIS LINE SHALL BE 1 INCH PER FGC TABLE | | | 402.4 (1). | | | 15) SHT. P5.402.2 - THE RISER SHOWS A 3/4 INCH LINE TO | | | ITEM # L2 WITH A BTU LOAD OF 350 MBH AND ALSO A 1 INCH | | | LINE SUPPLYING TWO ITEMS WITH THE SAME MBH LOAD OF 350. | | | CLARIFY AND SHOW THE CORRECT PIPE SIZE. | | | 16) SHT. P5.402.2 - SIZE THE LOW PRESSURE LINE | | | DOWNSTREAM OF THE PRESSURE REGULATOR AT GWH-1 AND TO | | | EACH HEATER AND SHOW THE MBH LOAD FOR BOTH HEATERS. | | | COMPLY WITH FGC TABLE 402.4 (1). | | | 17) SHT. P-5.402.2 - SIZE THE LOW PRESSURE LINES | | | DOWNSTREAM OF THE MP REGULATOR TO EQUIPMENT ITEMS | | | ERU-A-2-5 AND ERU-A-2-6. | | | 18) SHT. P5.403.1 - SIZE THE LOW PRESSURE LINE TO THE | | | FUTURE POOL HEATER DOWNSTREAM OF THE MP REGULATOR. THE | | | LINE SHALL BE A MINIMUM OF 1 1/4 INCHES PER 2014 FGC | | | TABLE 402.4 (1). | | | 19) SHT. P5.403.1 - SIZE THE LOW PRESSURE LINE TO UNIT | | | ERU-N-2-5 DOWNSTREAM OF THE MP REGULATOR. THE MINIMUM | | | SIZE SHALL BE 1 INCH. SHOW THE BTU LOAD AND SIZE THE | | | LINE UPSTREAM OF THE MP REGULATOR. | | | 20.) SHT. P5.403.1 - SIZE THE LOW PRESSURE LINE TO | | | ITEMS # 146 & #148. THE MINIMUM SIZE SHALL BE 1 INCH. | | | TABLE 402.4 (1) FGC. | | | 21) SHT. P5403.1 - THE 3/4 INCH MEDIUM PRESSURE LINE TO | | | ITEMS #146 AND 148 IS UNDERSIZED. THE MINIMUM SIZE | | | SHALL BE 1 INCH. TABLE 402.4 (5) FGC. | | | 22) SHT.P5.403.1 - THERE IS 1 INCH LOW PRESSURE LINE | | | SERVING OUTLETS ADJACENT TO ITEMS # 146 AND # 148 WITH | | | 350 MBH. THIS LINE IS UNDERSIZED AND SHALL BE 1 1/4 | | | INCHES. ALSO, IDENTIFY THE APPLIANCES ON THESE OUTLETS. | | | FGC TABLE 402.4 (1). THERE IS ALSO A 3/4 INCH LOW | | | PRESSURE LINE CARRYING 175 MBH. THIS LINE IS | | | UNDERSIZED. THE MINIMUM SIZE SHALL BE 1 INCH. | | | 23) SHT. P5.403.1 - SIZE THE LOW PRESSURE LINE TO | | | DHU-N-2-1. THE MINIMUM SIZE OF THIS LINE SHALL BE 1 | | | INCH. FGC TABLE 402.4 (1). | | | 24) SHT. P5.403.2 - THE 1 1/4 INCH LOW PRESSURE LINE TO | | | THE FOUR L2 ITEMS IS UNDERSIZED. THE MINIMUM SIZE SHALL | | | BE 1 1/2 INCHES. A MAXIMUM OF 583 MBH IS ALLOWED ON A 1 | | | 1/4 INCH LINE, 284 MBH ON A 1 INCH LINE, AND 151MBH ON | | | A 3/4 INCH LINE. THESE LINES ARE ALSO UNDERSIZED. THE | | | RISER SHOWS 700 MBH ON THIS LINE. ALSO, SHOW THE SIZE | | | OF THE DROPS TO THE EQUIPMENT AND THE BTU LOAD OF AT | | | EACH OUTLET. SIZE ALL SECTIONS OF THE SYSTEM AT THIS | | | AREA. FGC TABLE 402.4 (1). | | | 25) SHT. P5.403.2 - THE 1 INCH AND 3/4 INCH LOW | | | PRESSURE LINES TO ITEMS #37 AND #38 ARE UNDERSIZED. THE | | | MAXIMUM MBH LOAD ON A 3/4 INCH LINE AT 30 FT. IS 151 | | | MBH AND 284 MBH ON A 1 INCH LINE. THESE LINES SHALL BE | | | INCREASED TO 1 INCH AND 1 1/4 INCHES. FGC TABLE 402.4 | | | (1). | | | 26) SHT.P5.403.2 - THE 2 1/2 INCH LOW PRESSURE LINE TO | | | THE TWO GWH-1 WATER HEATERS IS UNDERSIZED. THE MAXIMUM | | | MBH ON A 2 1/2 INCH LINE AT 30 FT. IS 2680 MBH. THE | | | LINE NEEDS TO BE 3 INCH. TABLE 402.4 (1). | | | 27) SHT. K2.111.1 - ITEM #38 IS SHOWN WITH A 3/4 INCH | | | GAS SIZE BUT THE SCHEDULE ON SHT. P5.403 SHOWS THE GAS | | | SIZE AS 1 1/4 INCH. CLARIFY. | | | 28) SHT. K2.112.1 - THE UTILITY SCHEDULE SHOWS ITEM | | | 3146 WITH A 3/4 INCH GAS SIZE BUT SHT. P5.403 SHOWS AN | | | 1 1/4 GAS SIZE. CLARIFY. | | | 29) SHT. K2.113.1 - THE UTILITY SCHEDULE SHOWS ITEM # | | | 246 WITH A 3/4 INCH GAS SIZE BUT SHT. P5.402 SCHEDULE | | | SHOWS 1 1/4 INCHES.CLARIFY. | | | 30) SHT.K2.114.1 - THE UTILITY SCHEDULE SHOWS ITEM # | | | 354 WITH A 3/4 INCH GAS SIZE BUT SHT. P5.402 SCHEDULE | | | SHOWS 1 1/4 INCHES. CLARIFY. | | | 31) IDENTIFY THE L 2 APPLIANCE. I COULD NOT FIND THIS | | | ON THE UTILITY SCHEDULE. | | | 32) ENSURE THE GAS PIPE SIZES ON THE UTILITY SCHEDULES | | | CORRELATE WITH THE SCHEDULES ON THE GAS PLANS.2014 FBC | | | 107.2.1. | | | 33) THERE ARE STILL NUMEROUS AREAS ON THE GAS RISERS | | | WHERE PIPE SIZES ARE NOT SHOWN AND EQUIPMENT NOT | | | LABELED.ENSURE ALL SECTIONS ARE CLEARLY SIZED AND | | | OUTLETS LABELED AS TO THE EQUIPMENT BEING SERVED. 2014 | | | FBC 107.2.1. | | | 34) SUBMIT MANUFACTURER'S SPECIFICATION SHEETS FOR THE | | | LOUVERS BEING USED TO PROVIDE THE COMBUSTION AIR FOR | | | THE DRYERS AND SHOW THE LOCATIONS OF THE LOUVERS ON THE | | | ARCHITECTURAL AND PLUMBING PLANS. LOUVERS SHALL COMPLY | | | WITH THE 2014 FBC SEC.1609.1.2.1. SUBMIT PRODUCT | | | APPROVALS FOR THE LOUVERS SHOWING COMPLIANCE FOR WIND | | | LOAD REQUIREMENTS. | | | 35) WHERE ARE COMBUSTION AIR CALCULATIONS FOR THE REST | | | OF THE APPLIANCES SUCH AS THE COOKING EQUIPMENT IN THE | | | CONCESSION AREAS AND OTHER AREAS WHERE GAS FUELED | | | EQUIPMENT IS LOCATED IN ROOMS, AREAS OR OTHER TYPE OF | | | ENCLOSURES? 2014 FGC SEC.304.1, 304.5. | | | | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-05-24 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-05-24 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-05-11 |
Time |
12:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-04-28 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2016-04-28 |
Time |
15:22 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2016-04-15 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2016-04-15 09:09:12 | PLANS UNDER 16020418 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-03-11 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2016-03-11 |
Time |
07:50 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2016-02-16 |
Time |
10:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2016-05-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-05-19 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-05-17 |
Time |
13:44 |
Sent To |
|
|
| Notes |
| 2016-05-19 09:41:07 | MECHANICAL PROVISOS | | | 5/19/16 | | | | | | SEPARATE PERMITS ARE REQUIRED FOR ALL KITCHEN EXHAUST | | | HOODS AND FIRE SUPPRESSION SYSTEMS. | | | REVISIONS TO THE APPROVED PLANS SHALL BE PROVIDED TO | | | SHOW COMPLIANCE WITH THE FOLLOWING PROVISIONS. | | | | | | 1) DUCT SMOKE DETECTORS SHALL BE PROVIDED IN THE RETURN | | | AIR SYSTEMS OF THE ERUS. PROVIDE A NOTE IN THE | | | EQUIPMENT SCHEDULE. | | | | | | 2) THE DRYER EXHAUST DUCTS SHALL NOT EXTEND THROUGH THE | | | RETURN AIR PLENUMS. THE DUCTS SHALL BE RE-ROUTED OR | | | INSTALLED IN AN ENCLOSURE. | | | | | | 3) THE CONTRACTOR SHALL SUBMIT APPROVED SHOP DRAWINGS | | | FOR EQUIPMENT ACCESS PANELS. | | | | | | 4) CHEMICAL AND PAINT STORAGE ROOMS: PROVIDE ON THE | | | ARCHITECTURAL PLANS A COMPLETE LIST OF CHEMICALS AND | | | PAINTS TO BE STORED IN THE ROOMS, THE HAZARD | | | CLASSIFICATIONS FOR EACH PRODUCT, THE MAXIMUM ALLOWABLE | | | QUANTITIES FOR EACH, AND THE ACTUAL AMOUNTS TO BE | | | STORED. | | | | | | 5) FIRE DAMPER LOCATIONS, SCHEDULES, AND INSTALLATION | | | DETAILS. | | | | | | 6) FLORIDA PRODUCT APPROVALS AND/OR MIAMI-DADE NOA'S | | | FOR ALL EXTERIOR MECHANICAL EQUIPMENT INCLUDING RTU AND | | | FAN CURBS, ROOF AND WAL-MOUNTED FANS, AC STANDS, AND | | | LOUVERS ETC. SHALL BE REVIEWED AND APPROVED BY THE EOR, | | | AND SUBMITTED TO THE BUILDING DEPARTMENT FOR REVIEW AND | | | APPROVAL PRIOR TO 1ST INSPECTION. | | | | | | 7) PRIOR TO PASSING THE FINAL MECHANICAL INSPECTION, | | | THE REGISTERED DESIGN PROFESSIONAL SHALL PROVIDE | | | EVIDENCE OF MECHANICAL SYSTEM COMMISSIONING AND | | | COMPLETION IN ACCORDANCE WITH SECTION C408.2.4 AND | | | C408.2.5 FBC-14 ENERGY CONSERVATION. | | | | | | 8) REVISE SHEETS M2.114 & M2.117 TO INDICATE ADEQUATE | | | EXHAUST CAPACITIES IN THE LOCKER AND BATH ROOMS PER THE | | | CALCULATIONS ON SHEET M0.07. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2016-04-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-04-21 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-04-19 |
Time |
08:15 |
Sent To |
|
|
| Notes |
| 2016-04-21 11:45:57 | 2ND REVIEW: FBC 2014 MECHANICAL | | | PERMIT 16020418 | | | 4/19/16 | | | | | | THE SECOND REVIEW OF THE PROJECT IS BASED ON THE | | | REVISED PLANS AND NARRATIVE RESPONSES FROM WSP, AND | | | SOME OF THE1ST REVIEW ISSUES THAT STILL EXIST. | | | | | | 1) 1ST REVIEW COMMENT #2: REFER TO SHEET M0.07 & THE | | | FOLLOWING SHEETS WHERE LOCKER ROOM EXHAUST AT A RATE OF | | | .5 CFM PER SF. IS MISSING. A) M2.111- MEN'S AND WOMEN'S | | | LOCKER ROOMS 11102 &11103. B) M2.113- MLB COACHES | | | LOCKER 11302. C) M2.114- STAFF/COACHES LOCKER 11415 | | | (SEE SHEET M2.113 AND LABEL THE 16X14 EXHAUST RISER AND | | | ROOF FAN). M2.117- MLB COACHES LOCKER 11702. | | | 2) 1ST REVIEW COMMENT #4: M0.07, ERU CALCULATIONS- | | | REFER TO SECTION 403.2.1 ITEM #4. IT APPEARS BY THE | | | CALCULATION THAT MORE THAN 10% OF THE EXHAUST AIR FROM | | | THE LOCKER ROOM AND BATH AREAS IS BEING RECIRCULATED. | | | PLEASE SUBMIT MANUFACTURER'S PRODUCT DATA SHEETS FOR | | | THE ERU'S. | | | 3) 1ST REVIEW COMMENT #2: M0.07: VENTILATION | | | CALCULATIONS FOR THE DHU'S NOT PROVIDED. PLEASE PROVIDE | | | THE CALCULATIONS AND MANUFACTURER'S PRODUCT DATA | | | SHEETS. | | | 4) 1ST REVIEW COMMENT #5: A) SHEET M0.02: PLACE A NOTE | | | FOR REQUIRED DUCT SMOKE DETECTORS IN THE ERU SCHEDULE. | | | B) M0.05: PLACE A NOTE REQUIRING A DUCT SMOKE DETECTOR | | | FOR AHU-S-4-1. C) M701, NOTE M: PLEASE PROVIDE | | | ADDITIONAL INFORMATION PERTAINING TO FAN SHUT DOWN. | | | CLARIFY WHICH FANS WILL SHUT DOWN WHEN A DETECTOR | | | ACTIVATES- THE UNIT FAN, FANS IN THE FIRE AREA, BOTH | | | SUPPLY AND EXHAUST FANS IN THE FIRE AREA? D) IT MAY BE | | | HELPFUL TO PLACE DS SYMBOLS AT THE REQUIRED LOCATIONS | | | ON THE LAYOUT PLANS. | | | 5) M2.111, CHEMICAL AND PAINT STORAGE, 1ST REVIEW | | | COMMENT #6: A) THE LETTER TITLED "LTAS BALLPARK OF THE | | | PALM BEACHES-HAZMAT STORAGE.." AS NOTED IN THE | | | NARRATIVE RESPONSE, WAS NOT UPLOADED FOR REVIEW, | | | THEREFORE A COMPLETE REVIEW CANNOT BE COMPLETED AT THIS | | | TIME. B) COMMENTS #6C- EXHAUST VENTILATION | | | CALCULATIONS, AND #6D- MAKE UP AIR SOURCE LOCATION FOR | | | THE EXHAUST STILL EXIST. | | | 6) M0.06, COMMENT #16: PLEASE INDICATE WHICH MUA'S | | | LISTED IN THE SCHEDULE ON M0.05 CORRESPOND WITH THE AIR | | | BALANCE CALCULATIONS. AS PREVIOUSLY NOTED, THE KITCHEN | | | HOODS AND ALL ASSOCIATED MAKE-UP AIR AND EXHAUST | | | SYSTEMS AND FIRE SUPPRESSION WILL BE DONE UNDER | | | SEPARATE PERMIT. A) PLEASE REVIEW THE MUA SCHEDULE ON | | | M0.05: THE SECTOR LOCATIONS OF THE MUA'S ON THE | | | CONCOURSE LEVELS DO NOT APPEAR TO MATCH THE LOCATIONS | | | SHOWN ON THE PLANS. | | | 7) M2.112, M2.117, M2.118, M2.119 COMMENT #17: PLEASE | | | CLARIFY IF THE C, E & G TRANSFERS ARE TRANSFERRING THE | | | AIR ABOVE OR BELOW THE CORRIDOR CEILINGS ON THESE PLANS | | | AND OTHER PLANS WITH CORRIDORS. | | | 8) M2.113, COMMENT #21: COMBUSTION AIR AND LOCATION OF | | | GIH-N-2-1 NOT SHOWN. | | | 9) M2.114, COMMENT #22 STILL EXISTS. REFER TO COMMENT | | | #2 OF THIS REVIEW. | | | 10) M2.117, COMMENT #25 COMBUSTION AIR CALCULATION AND | | | SOURCE OF THE AIR. | | | 11) M2.120, COMMENT #26: FOR CLARIFICATION PLEASE | | | INDICATE THE TYPE OF EXHAUST DUCTWORK FOR THE TYPE 1 | | | HOODS. | | | 12) 1ST REVIEW COMMENT #27: THE REQUESTED WIND LOAD | | | ENGINEERED INSTALLATION DETAILS FOR THE ROOFTOP | | | MECHANICAL EQUIPMENT HAS NOT BEEN PROVIDED. REFERENCE | | | IS MADE TO THE STRUCTURAL DRAWINGS IN THE NARRATIVE, | | | HOWEVER NO EXACT SHEET IS REFERENCED AND THE REFERENCE | | | TO ARCHITECTURAL SHEET A7.21 DOES NOT PROVIDE ANY INFO. | | | PLEASE NOTE THAT THE REQUIRED ENGINEERING CAN BE DONE | | | AS A DEFERRED SUBMITTAL, HOWEVER REQUIRED MECHANICAL | | | INSPECTIONS WILL BE ON HOLD UNTIL ENGINEERING HAS BEEN | | | REVIEWED AND APPROVED. GIVEN THE AMOUNT OF EQUIPMENT TO | | | BE INSTALLED, IT IS HIGHLY RECOMMENDED THAT ENGINEERING | | | IS EXPEDITED BY THE DESIGN PROFESSIONALS IN ORDER TO | | | AVOID ANY DELAYS. | | | 13) M2.125, COMMENT #28: ENVIRONMENTAL AIR AS DEFINED | | | IN SECTION 202 DOES NOT INCLUDE AIR EXHAUSTED FROM | | | STORAGE ROOMS. PLEASE RELOCATE ALL EXHAUST OUTLETS TO | | | MINIMUM 10' ABOVE ADJOINING GRADE AND REFER TO SECTIONS | | | 501.3, 501.3.1 (2), AND 501.3.1.1 FOR ADDITIONAL | | | COMPLIANCES. | | | 14) 1ST REVIEW COMMENT #31A: IN RESPONSE TO THIS | | | COMMENT ABOUT REQUIRED EQUIPMENT ACCESS PANELS, THE | | | NARRATIVE STATES THE CONTRACTOR MAY PROVIDE A CEILING | | | COORDINATION DRAWING DURING CONSTRUCTION. RESPECTFULLY, | | | THE BUILDING DIVISION WILL REQUIRE THE DESIGN | | | PROFESSIONALS TO PROVIDE THOSE DRAWINGS INDICATING | | | PANEL LOCATIONS, PANEL SIZES, AND CONSTRUCTION DETAILS. | | | PLEASE NOTE THAT PANELS SHALL BE SIZED LARGE ENOUGH TO | | | REMOVE AND REPLACE THE EQUIPMENT LOCATED ABOVE THE | | | CEILINGS- SECTION 306.1. | | | 15) 1ST REVIEW COMMENT #33A: UL APPROVED FIRE STOPPING | | | ASSEMBLIES ARE REQUIRED FOR REFRIGERANT PIPING | | | PENETRATING FIRE-RATED WALLS AND FLOORS. PLEASE REVISE | | | DETAIL 2/M6.-01. | | | 16) 1ST REVIEW COMMENT #34: THE REQUESTED DETAILS WERE | | | NOT PROVIDED, AND REFERENCE TO THE PROJECT | | | SPECIFICATION BOOK WAS MADE IN THE NARRATIVE, HOWEVER | | | WE DO NOT REVIEW SPEC BOOKS. PLEASE PROVIDE DETAILS ON | | | THE PLANS. | | | 17) 1ST REVIEW COMMENT #35, SHEET M7.02: PLEASE PROVIDE | | | THE CONTROLS OPERATION FOR THE DHU'S AND A SYMBOL | | | LEGEND. | | | 18) SHEET M0.04: THE GAGE OF ALUMINUM DUCTWORK IS | | | INDICATED TO BE 14 INCHES- PLEASE CLARIFY. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-03-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-03-09 |
Time |
17:37 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-03-08 |
Time |
12:16 |
Sent To |
|
|
| Notes |
| 2016-03-09 17:41:06 | 1ST REVIEW: FBC 2014 MECHANICAL | | | PERMIT #16020418 | | | BALLPARK OF THE PALM BEACHES | | | 3/8/16 | | | | | | 1) THE DESIGN PROFESSIONALS OF RECORD MUST SIGN AND | | | PROVIDE THEIR PROFESSIONAL REGISTRATION NUMBERS ON PAGE | | | 3 OF THE ENERGY CONSERVATION FORM SUBMITTAL- SEE | | | SECTION C103.1.1.1.2 FBC-14 ENERGY CONSERVATION. | | | 2) DISCREPANCIES BETWEEN THE ENERGY FORM AND THE | | | MECHANICAL PLANS: | | | A) THE FORM LISTS ERU-A-2-5 CAPACITY AT 75300 BTUH , | | | THE AC SCHEDULE ON SHEET M0.02 LISTS THE CAPACITY AT | | | 92000 BTUH | | | B) ENERGY FORM LISTS ERU-A-2-6 AT 75300, SCHEDULE- | | | 92,000. | | | C) ENERGY FORM LISTS COMPLIANCE DATA FOR AHU-S-2-4 , | | | HOWEVER THIS SYSTEM IS NOT INCLUDED IN THE EQUIPMENT | | | SCHEDULES ON THE PLANS. | | | D) THE SPLIT SYSTEMS, THE 100% O/A SYSTEMS, THE DHU'S, | | | THE COMPUTER ROOM AC, AND MANY OF THE VRF SYSTEMS ARE | | | NOT LISTED IN THE ENERGY CONSERVATION FORM. | | | 3) THE AC COOLING AND HEATING CALCULATIONS MUST BE | | | SIGNED AND SEALED BY THE DESIGN PROFESSIONAL OF RECORD: | | | SECTION C403.2.1 FBC-14 ENERGY CONSERVATION. | | | 4) DISCREPANCIES BETWEEN THE AC CALCULATIONS AND THE | | | MECHANICAL PLANS: | | | A) CALCULATED COOLING LOAD FOR ACC-S-4 IS 391 MBH, | | | HOWEVER THE SCHEDULE ON SHEET M0.04 INDICATES THE | | | CAPACITY AT 528 MBH. | | | B) AHU-A-2-1 COOLING LOAD- 925 MBH / SCHEDULE ON SHEET | | | M0.02 INDICATES CAPACITY AT 836 MBH | | | C) AHU-N-2-1 LOAD- 695 MBH/ SCHEDULE- 835 MBH. | | | D) AHU-N-2-2 LOAD- 786 MBH/ SCHEDULE- 732 MBH. | | | E) AHU- S-3-1 LOAD- 121.9 MBH/SCHEDULE- 197 MBH. | | | F) AHU-S-3-2 LOAD- 52.8 MBH/ SCHEDULE- 87 MBH. | | | G) AHU-S-3-4 LOAD- 58 MBH/ SCHEDULE-83. | | | H) AHU-S-2-4 IS SHOWN IN THE CALCS BUT NOT IN THE | | | SCHEDULES. | | | I) AHU-S-3-5 IS SHOWN IN THE SCHEDULE BUT NOT IN THE | | | CALCS. | | | J) DHU-N-2-1 LOAD- 81.3 MBH/SCHEDULE- 133 MBH. | | | K) ERU-A-2-5 LOAD- 245.7 MBH/ SCHEDULE- 92 MBH | | | L) ERU-A-3-1 LOAD- 131.8 MBH/ SCHEDULE- 92 MBH. | | | M) ERU-N-2-5 LOAD- 180 MBH/ SCHEDULE- 112.5 MBH. | | | N) ERU-N-2-6 LOAD- 286.6 MBH/ SCHEDULE- 92 MBH. | | | O) CLARIFY WHICH SYSTEMS WERE SIZED UNDER THE LOAD | | | CALCULATIONS PAGES TITLED "MISC" AND "SYSTEM 023": I | | | CANNOT CONNECT THESE UP WITH THE AC SCHEDULES. | | | IN REFERENCE TO THE DISCREPANCIES ABOVE PLEASE REFER TO | | | SECTION C403.2.2 FBC-14 ENERGY CONSERVATION. | | | | | | 2) SHEETS M0.03: INDICATE HOW EACH EXHAUST FAN IN THE | | | SCHEDULE WAS SIZED: PROVIDE EXHAUST VENTILATION | | | CALCULATIONS IN ACCORDANCE WITH TABLE 403.3 FBC-14 | | | MECHANICAL, AND TABLE 6-4 ASHRAE 62.1-2010. | | | 3) M0.04: REFER TO TABLE C403.2.3(10) FBC ENERGY | | | CONSERVATION AND PROVIDE THE SCOP RATING FOR THE | | | COMPUTER ROOM AC UNITS. | | | 4) M2.03 & M2.04: THE PLANS APPEAR TO INDICATE | | | MECHANICAL SYSTEMS ON THE SUITE AND ROOF LEVELS OF | | | SECTOR A, HOWEVER THERE ARE NO ENLARGED PLANS FOR THOSE | | | AREAS IN THE SETS AND THERE ARE ROOF TOP UNITS ON THE | | | CONCOURSE LEVEL OF SECTOR A- PLEASE CLARIFY. | | | 5) DUCT SMOKE DETECTORS ARE REQUIRED IN RETURN AIR | | | SYSTEMS WITH DESIGN CAPACITIES GREATER THAN 2000 CFM | | | PER SECTION 606.2.1 FBC-14 MECHANICAL. MANY OF THE | | | PROPOSED AC SYSTEMS FOR THE PROJECT HAVE RETURN AIR | | | SYSTEMS EXCEEDING THAT THRESHOLD. PLEASE PROVIDE DS | | | DETECTOR SYMBOLS ON THE PLANS WHERE APPLICABLE, AND | | | PROVIDE NOTES AND DETAILS CLARIFYING THE SEQUENCE OF | | | OPERATION FOR THE DETECTORS AND HOW THEY WILL BE | | | SUPERVISED- SECTION 606.4.1. PLEASE INCLUDE AN | | | INSTALLATION DETAIL FOR THE DEVICES AND A PRODUCT | | | SUBMITTAL APPROVED BY THE ENGINEER OF RECORD. | | | 6) M2.110 AND ALL MECH. PLAN SHEETS: NUMEROUS SYMBOLS | | | FOR ACCESS PANELS ARE SHOWN FOR THE ABOVE CEILING CAV'S | | | AND VAV'S. REFER TO SECTION 306.1 AND PROVIDE THE | | | DIMENSION AND CONSTRUCTION DETAILS FOR THE PANELS. | | | PLEASE NOTE THE PANELS SHALL BE LARGE ENOUGH TO REMOVE | | | AND REPLACE THE EQUIPMENT WITHOUT REMOVING PERMANENT | | | CONSTRUCTION. | | | 7) M2.111: PROVIDE A KEY NOTE IDENTIFYING WHICH AC | | | SYSTEM IS PROVIDING THE 20X16 SUPPLY AND RETURN DUCT | | | DROPS. | | | 8) M2.111: PROVIDE KEY NOTES IDENTIFYING WHICH EXHAUST | | | FANS ARE SERVICING THE EXHAUST DUCT RISERS SHOWN IN THE | | | AREA OF THE CHEMICAL AND PAINT STORAGE ROOMS. | | | 9) M2.111: CHEMICAL AND PAINT STORAGE ROOMS: A) REFER | | | TO SECTION 414.1.3 FBC-14 BUILDING: [F] 414.1.3 | | | INFORMATION REQUIRED. | | | A REPORT SHALL BE SUBMITTED TO THE BUILDING OFFICIAL | | | IDENTIFYING THE MAXIMUM EXPECTED QUANTITIES OF | | | HAZARDOUS MATERIALS TO BE STORED, USED IN A CLOSED | | | SYSTEM AND USED IN AN OPEN SYSTEM, AND SUBDIVIDED TO | | | SEPARATELY ADDRESS HAZARDOUS MATERIAL CLASSIFICATION | | | CATEGORIES BASED ON TABLES 307.1(1) AND 307.1(2). THE | | | METHODS OF PROTECTION FROM SUCH HAZARDS, INCLUDING BUT | | | NOT LIMITED TO CONTROL AREAS, FIRE PROTECTION SYSTEMS | | | AND GROUP H OCCUPANCIES SHALL BE INDICATED IN THE | | | REPORT AND ON THE CONSTRUCTION DOCUMENTS. THE OPINION | | | AND REPORT SHALL BE PREPARED BY A QUALIFIED PERSON, | | | FIRM OR CORPORATION APPROVED BY THE BUILDING OFFICIAL | | | AND PROVIDED WITHOUT CHARGE TO THE ENFORCING AGENCY. | | | FOR BUILDINGS AND STRUCTURES WITH AN OCCUPANCY IN GROUP | | | H, SEPARATE FLOOR PLANS SHALL BE SUBMITTED IDENTIFYING | | | THE LOCATIONS OF ANTICIPATED CONTENTS AND PROCESSES SO | | | AS TO REFLECT THE NATURE OF EACH OCCUPIED PORTION OF | | | EVERY BUILDING AND STRUCTURE. | | | B) PROVIDE ON THE PLAN AN ITEMIZED LIST OF THE | | | HAZARDOUS MATERIALS TO BE STORED AND THEIR EXPECTED | | | QUANTITIES, AND SUBMIT MSDS SHEETS FOR EACH ITEM. C) | | | PROVIDE EXHAUST VENTILATION CALCULATIONS FOR EACH | | | EXHAUST SYSTEM, INDICATE THE TYPE OF EXHAUST DUCTWORK | | | TO BE INSTALLED, AND SEQUENCE OF OPERATION FOR THE | | | FANS- SEE SECTIONS 502.8.1.1 & 510.1- 510.9. PLEASE | | | NOTE THAT FIRE SUPPRESSION MAY BE REQUIRED FOR THE | | | EXHAUST DUCTS. D) REFER TO SECTION 510.5.5 AND INDICATE | | | HOW MAKE-UP AIR IS BEING PROVIDED FOR THE SYSTEMS AND | | | THE RATE. PLEASE NOTE THAT THE SOURCE OF THE MAKE-UP | | | AIR MUST BE DIRECTLY FROM THE OUTDOORS AND TRANSFER | | | DUCTS FROM ADJOINING ROOMS CANNOT BE USED. | | | 10) M2.111: FIRE DAMPERS ARE REQUIRED FOR THE 12X12 | | | LOCKER AND RESTROOM EXHAUST DUCT PENETRATING THE | | | FIRE-RATED PAINT STORAGE WALLS IN ACCORDANCE WITH | | | SECTION 607.5.2 FBC-14 MECHANICAL. | | | 11) M2.111: PROVIDE THROUGH-PENETRATION FIRESTOPPING | | | SYSTEM DETAILS FOR DUCTS PENETRATING FIRE-RATED WALLS- | | | SEE SECTION 714.1.1 FBC-14 BUILDING. | | | 12) M2.111: INDICATE THE REQUIRED CLEARANCES FOR THE | | | EXHAUST OUTLETS FROM EF S-1-1 AND EF S-1-2: REFER TO | | | SECTION 501.3.1 FBC-14 MECHANICAL. IDENTIFY THE ROOMS | | | IN THE MAINTENANCE MEZZANINE AND INDICATE A SOURCE OF | | | MAKE-UP AIR FOR THE EXHAUST SYSTEMS. | | | 13) M2.111: PLEASE NOTE THAT ALL EXTERIOR EXHAUST | | | OUTLET AND AIR INTAKE OPENINGS SHOWN ON THIS PLAN SHEET | | | AND ALL OTHERS MUST BE PROTECTED IN ACCORDANCE WITH | | | SECTIONS 1609.1.2 AND 1609.6.4.4.1 FBC-14 BUILDING. | | | MIAMI-DADE NOA'S AND/OR FLORIDA PRODUCT APPROVALS SHALL | | | BE SUBMITTED FOR ALL COMPONENTS AND CLADDINGS WITH | | | REVIEW AND APPROVAL SIGNATURES FROM THE DESIGN | | | PROFESSIONALS OF RECORD. | | | | | | 14) M2.112, LAUNDRY: A) PROVIDE AN EQUIPMENT SCHEDULE | | | ON THE PLAN FOR THE DRYERS AND SUBMIT MANUFACTURER'S | | | SPECIFICATIONS REVIEWED AND APPROVED BY THE DESIGN | | | PROFESSIONAL OF RECORD. B) A COMBUSTION AIR INTAKE DUCT | | | IS INDICATED- PROVIDE COMBUSTION AIR CALCULATIONS FOR | | | SIZING THE DUCT. C) EXPAND NUMBERED NOTE #5 TO INDICATE | | | THE TYPE AND GAGE OF DUCT MATERIAL, THE INTAKE HOOD THE | | | DUCT IS CONNECTED TO, AND HOW THE DUCT WILL BE | | | SUPPORTED. D) EXPAND NUMBERED NOTE #1 TO INDICATE | | | COMPLIANCE WITH SECTION 504.7: COMMERCIAL CLOTHES | | | DRYERS. | | | THE INSTALLATION OF DRYER EXHAUST DUCTS SERVING | | | COMMERCIAL CLOTHES DRYERS SHALL COMPLY WITH THE | | | APPLIANCE MANUFACTURER'S INSTALLATION INSTRUCTIONS. | | | EXHAUST FAN MOTORS INSTALLED IN EXHAUST SYSTEMS SHALL | | | BE LOCATED OUTSIDE OF THE AIRSTREAM. IN MULTIPLE | | | INSTALLATIONS, THE FAN SHALL OPERATE CONTINUOUSLY OR BE | | | INTERLOCKED TO OPERATE WHEN ANY INDIVIDUAL UNIT IS | | | OPERATING. DUCTS SHALL HAVE A MINIMUM CLEARANCE OF 6 | | | INCHES (152 MM) TO COMBUSTIBLE MATERIALS. CLOTHES DRYER | | | TRANSITION DUCTS USED TO CONNECT THE APPLIANCE TO THE | | | EXHAUST DUCT SYSTEM SHALL BE LIMITED TO SINGLE LENGTHS | | | NOT TO EXCEED 8 FEET (2438 MM) IN LENGTH AND SHALL BE | | | LISTED AND LABELED FOR THE APPLICATION. TRANSITION | | | DUCTS SHALL NOT BE CONCEALED WITHIN CONSTRUCTION. E) | | | SEE TABLE 403.3 AND PROVIDE OUTSIDE AIR CALCULATIONS | | | FOR THE LAUNDRY AREA. F) SUBMIT SPECS FOR THE ENERVEX | | | MEC 18 EXHAUST CONTROL SYSTEM REVIEWED AND APPROVED BY | | | THE DESIGN PROFESSIONAL OF RECORD. | | | 15) M2.112: PROVIDE NUMBERED KEY NOTES AT THE MAIN | | | SUPPLY AND RETURN DUCT DROPS TO IDENTIFY WHICH AC AND | | | ERU SYSTEMS ARE SERVICING THE AREAS. | | | 16) M2.112: THE KITCHEN HOOD EXHAUST AND FIRE | | | SUPPRESSION SYSTEMS SHALL BE DONE UNDER A SEPARATE | | | PERMIT- PLEASE PLACE A NOTE ON THE PLAN ACCORDINGLY AND | | | PROVIDE AN AIR BALANCE CALCULATION FOR THE AREA. PLEASE | | | NOTE ALL OTHER KITCHEN HOOD EXHAUST AND FIRE | | | SUPPRESSION SYSTEMS THROUGHOUT THE FACILITY WILL ALSO | | | BE DONE UNDER SEPARATE PERMIT WITH AIR BALANCE CALCS | | | REQUIRED FOR EACH. | | | 17) M2.112: I AM NOT SEEING ANY OUTSIDE AIR | | | CALCULATIONS IN THE SCHEDULES FOR THE CORRIDOR | | | SERVICING THIS SECTOR OR CALCULATIONS FOR ANY OF THE | | | OTHER SECTOR CORRIDORS- REFER TO TABLE 403.3 AND | | | PROVIDE THE CALCULATIONS. IT ALSO NEEDS TO BE VERIFIED | | | THAT THE CORRIDORS IN ALL SECTORS ARE NOT SERVING AS | | | SUPPLY, RETURN, EXHAUST, RELIEF, OR VENTILATION AIR | | | DUCTS PER SECTION 601.2. AS NOTED IN SECTION 601.2.1, | | | THE CEILINGS ABOVE THE CORRIDORS MAY SERVE AS RETURN | | | AIR PLENUMS. | | | 18) M2.113: EXPAND NUMBERED NOTE #11 TO INDICATE WHICH | | | AC SYSTEM | | | 19) M2.113: PLACE A NUMBERED NOTE ON THE PLAN TO | | | INDICATE WHERE THE HVAC SYSTEMS FOR THE HYDRO ROOM CAN | | | BE FOUND. | | | 20) INDICATE THE REQUIRED CLEARANCE DISTANCE | | | MEASUREMENTS FOR THE EXHAUST OUTLET FOR EF N-1-3. REFER | | | TO COMMENT #12 ABOVE FOR MORE INFO. | | | 21) M2.113: REFER TO COMMENTS # 13 AND 15 FOR THE | | | LAUNDRY AND KITCHEN AREAS ON THIS PLAN SHEET. | | | 22) M2.114: PROVIDE AN EXHAUST SYSTEM AND CALCULATIONS | | | FOR THE STAFF/COACHES LOCKER ROOM- SEE TABLE 403.3. | | | 23) M2.115 & M2.412: THE 8" ROUND UNDERGROUND EXHAUST | | | DUCT FROM THE DUGOUT SHALL BE CONSTRUCTED OF PVC HAVING | | | A MINIMUM PIPE STIFFNESS OF 8 PSI AT 5-PERCENT | | | DEFLECTION WHEN TESTED IN ACCORDANCE WITH ASTM D2412. | | | PROVIDE A SUBMITTAL FOR THE DUCT REVIEWED AND APPROVED | | | BY THE DESIGN PROFESSIONAL OF RECORD. | | | 24) M2.115: PROVIDE A NUMBERED KEY NOTE IDENTIFYING | | | WHICH AC SYSTEM THE 24X14 SUPPLY AND 26X20 RETURN DUCT | | | DROPS ARE CONNECTED TO. | | | | | | 25) SHEETS M2.117, 118, & 119- CLUBHOUSE SECTORS H, J, | | | & K: MANY OF THE COMMENTS PRINTED ABOVE FOR SHEETS | | | M2.111, 112, 113, 114, & 115 (NATIONAL'S CLUBHOUSE) CAN | | | APPLIED TO THESE PLAN SHEETS AND SECTORS FOR THE ASTROS | | | CLUBHOUSE INCLUDING: A) REQUIRED EXHAUST SYSTEM AND | | | CALCULATIONS FOR THE MLB COACHES LOCKER ROOM (M2.117). | | | B) LAUNDRY AND KITCHEN AREAS. C) AC SYSTEM | | | IDENTIFICATIONS AT DUCT DROPS. D) EXHAUST OUTLET AND | | | AIR INLET CLEARANCE DISTANCES. E) NOA?S AND PRODUCT | | | APPROVALS. F) OUTSIDE AIR FOR CORRIDORS. | | | 26) M2.120: EXPAND GENERAL NOTE A TO INDICATE THE GAGE | | | OF ALUMINUM DUCTWORK. | | | 27) M2.120, 121, 122, 123, 127, 128, 129, 132, 134, | | | 135, 136, 137, 138, 139, 145: WIND LOAD ENGINEERING IS | | | REQUIRED FOR THE ROOF-MOUNTED ERU'S, AHU'S, ACC'S CU'S, | | | EF'S, MUA'S, DUH'S, GIH'S, AND ALL OTHER ROOF MOUNTED | | | EQUIPMENT, COMPONENTS, AND DUCTWORK- SECTION 301.15 | | | PROVIDE STRUCTURAL DETAILS ACCORDINGLY INCLUDING | | | SECTION CUTS INDICATING CURB HEIGHTS ABOVE THE ROOF | | | SURFACES, CURB TO STRUCTURE AND UNIT TO CURB | | | ATTACHMENTS, STAND TO STRUCTURE AND UNIT TO STAND | | | ATTACHMENTS ETC. IF THE DETAILS ARE FOUND ON | | | ARCHITECTURAL OR STRUCTURAL SHEETS PLEASE PLACE NOTES | | | ON THE PLAN INDICATING THE SHEET AND DETAIL NUMBERS. | | | 28) M2.125: A) PROVIDE EXHAUST OUTLET CLEARANCE | | | DISTANCES FOR EF-S-2-5 AND PROTECTION FOR THE OPENING. | | | B) IDENTIFY WITH A NUMBERED NOTE WHICH AC SYSTEM IS | | | PROVIDING THE O/A DROP. C) SEPARATE PERMITS REQUIRED | | | FOR THE KITCHEN HOOD GREASE EXHAUST AND FIRE | | | SUPPRESSION SYSTEMS D) IDENTIFY WITH A NOTE WHICH AC | | | SYSTEM IS PROVIDING THE 28X20 SA AND RA DROPS. E) | | | NUMBERED NOTE #5 INDICATES CONDENSATE FROM AC S-2-1 & | | | S-2-4 DISCHARGING INTO A PLUMBING DRAIN- PLEASE NOTE | | | THAT THIS CONDENSATE AND ALL OTHER CONDENSATE FROM AC | | | COOLING COILS IS PROHIBITED TO DRAIN INTO THE WPB | | | SANITY SEWER SYSTEM PER SEC. 90-126 WPB CODE OF | | | ORDINANCES. | | | 29) M2.126: IDENTIFY WITH A NOTE WHICH AC SYSTEM IS | | | PROVIDING THE 20X12 AND 18X12 SA AND RA DROPS. | | | 30) M2.129: I AM NOT SEEING MAU S-3-6 IN THE EQUIPMENT | | | SCHEDULES- PLEASE INDICATE WHERE IT IS LOCATED. PLEASE | | | NOTE THAT THE VENTILATION CALCULATION AND EQUIPMENT | | | SCHEDULES DO NOT LIST THIS UNIT. MAU-N-2-6 & MAU-N-2-7 | | | ARE LISTED IN THE VENTILATION SCHEDULES HOWEVER I CAN?T | | | FIND THEM ON THE PLANS ON IN THE EQUIPMENT SCHEDULES- | | | PLEASE CLARIFY AND INDICATE HOW THESE SYSTEMS WERE | | | SIZED. | | | 31) M2.132, 134, 135 & M0.07: THE VENTILATION | | | CALCULATIONS ARE INCORRECT FOR THE SUITES AND OTHER | | | SPECTATOR AREAS ON THE SUITE LEVEL. REFER TO TABLE | | | 403.3 FBC-14 MECHANICAL: SPECTATOR AREAS ARE CALCULATED | | | AT 150 PEOPLE PER 1000 SQ.FT. AND REQUIRE 7.5 CFM PER | | | PERSON- PLEASE CORRECT. A) PROVIDE ACCESS PANEL SYMBOLS | | | FOR THE FCU?S AND DIMENSIONED DETAILS FOR INSTALLATION | | | OF THE PANELS. | | | 32) M4.01, 402: EXPAND NOTE #3 TO INDICATE WHICH AC | | | SYSTEM IS PROVIDING THE SA AND RA DROPS TO THE AREAS. | | | 33) M4.02: PROVIDE AN EQUIPMENT SCHEDULE FOR THE SF | | | N-1-4, AND DETAILS FOR WIND LOAD ENGINEERING FOR | | | ANCHORING THE FAN AND DUCTWORK- SECTION 301.15. | | | 34) M4.02 & 403.: THE REFRIGERANT PIPING DIAGRAMS ARE | | | INCOMPLETE: PROVIDE DIAGRAMS FOR ALL SYSTEMS AND | | | INCLUDE PIPE AND PIPE INSULATION SPECIFICATIONS, AND | | | FIRESTOPPING DETAILS FOR ALL PIPES PENETRATING | | | FIRE-RATED WALLS OR FLOOR/CEILING ASSEMBLIES | | | 34) M.602 & 603: PROVIDE SUPPORT AND HANGING DETAILS | | | FOR INSTALLATION OF THE FCU?S, THE VAV AND CAV BOXES, | | | THE INLINE FANS, THE G90 AND ALUMINUM DUCTWORK, AND THE | | | FLEX DUCTS. INCLUDE CONNECTION AND REINFORCEMENT | | | DETAILS FOR ALL DUCTWORK, AND TYPES AND SIZES OF | | | HANGERS AND FASTENERS- REFER TO TABLE C403.2.7.2 FBC-14 | | | ENERGY CONSERVATION AND SMACNA HVAC DUCT CONSTRUCTION | | | STANDARDS-2005. | | | | | | 35) REFER TO SECTION C403.2.4.4 FBC-14 ENERGY | | | CONSERVATION: PROVIDE SHUTOFF DAMPER CONTROLS FOR | | | OUTDOOR AIR SUPPLY AND EXHAUST DUCTS WHERE REQUIRED. | | | 36) REFER TO SECTION C408: COMMISSIONING OF THE | | | MECHANICAL AND ELECTRICAL POWER AND LIGHTING SYSTEMS IS | | | REQUIRED. PLEASE REVIEW ALL SUB-SECTIONS UNDER C408 AND | | | SUBMIT A COMMISSIONING PLAN FOR REVIEW. | | | 37) PROVIDE A SUBMITTAL PACKAGE FOR ALL MECHANICAL | | | EQUIPMENT AND COMPONENTS INCLUDING BUT NOT LIMITED TO | | | THE AC SYSTEMS, EXHAUST AND SUPPLY FANS, ROOF TOP CURBS | | | AND STANDS, EXHAUST OUTLET AND AIR INLET LOUVERS, DUCT | | | SMOKE DETECTORS, FIRE DAMPERS, THE DRYERS, ETC. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2016-06-16 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-06-16 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-06-16 |
Time |
08:43 |
Sent To |
|
|
| Notes |
| 2016-06-16 08:44:52 | PROVISO | | | | | | PLANS SHALL BE SUBMITTED FOR THE OZONE GENERATING | | | EQUIPMENT PRIOR TO THE INSTALLATION OF THE EQUIPMENT. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2016-05-12 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-05-12 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-05-12 |
Time |
03:45 |
Sent To |
|
|
| Notes |
| 2016-05-12 09:55:17 | THESE PROVISO NOTES ARE ALSO ON THE PLANS. | | | **** NOTE**** THE FOLLOWING COMMENTS ARE PROVISOS FOR | | | THE PLUMBING PLAN REVIEW ONLY. | | | 1) THE GAS PERMIT AND PLAN REVIEW WILL BE DONE AS A | | | SEPARATE PERMIT AND IS NOT PART OF THIS SUBMITTAL | | | PACKAGE. | | | 2) SHT.IR1.07 - THE ACID INJECTION SYSTEM FOR THE | | | IRRIGATION SYSTEM SHALL BE UNDER A SEPARATE PERMIT. | | | COMPLETE PLANS AND SPECIFICATIONS SHALL BE SUBMITTED | | | FOR REVIEW. | | | 3) THE LAUNDRY AREAS IN THE CLUBHOUSES SHALL COMPLY | | | WITH THE 2014 FBC- ACCESSIBILITY SECS. 611 & 309. ALL | | | WASHERS AND DRYERS SHALL COMPLY WITH THE REQUIREMENTS | | | FOR CLEAR FLOOR SPACE, OPERABLE PARTS, AND HEIGHT. | | | 4) SHT.P4.003 - APPROVAL IS REQUIRED FROM THE PALM | | | BEACH COUNTY DEPARTMENT OF ENVIRONMENTAL RESOURCE | | | MANAGEMENT FOR THE ABOVE GROUND FUEL STORAGE TANKS AND | | | DISPENSING SYSTEM PER PALM BEACH COUNTY ORDINANCE | | | #2015-008. THE FUEL TANKS AND FUEL DISPENSING SYSTEM | | | SHALL BE DONE AS A SEPARATE PERMIT. | | | 5) THE SANITARY AND WATER RISERS ARE INCOMPLETE AND | | | DEFICIENT AND A THOROUGH AND COMPREHENSIVE REVIEW COULD | | | NOT BE DONE AT THIS TIME. AS-BUILT SANITARY AND WATER | | | RISERS SHALL BE SUBMITTED DURING THE INSPECTION PROCESS | | | FOR THESE SYSTEMS. | | | 6) SHT. A3.23 - ACCESSIBLE ROLL-IN SHOWER WITH GRAB BAR | | | AND SEAT DETAIL SH - 3. ALTERNATE ROLL-IN SHOWER | | | COMPARTMENTS SHALL COMPLY WITH 2014 FBC-ACCESSIBILITY | | | SEC. 608.2.3 FOR ENTRY OPENING AND LAYOUT, SEC.608.3 | | | FOR THE LOCATION OF GRAB BARS, SEC. 608.5.3 FOR THE | | | LOCATION OF CONTROLS, FAUCETS AND SHOWER SPRAY UNITS, | | | AND SEC.610.3 FOR SEATS. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2016-04-28 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-04-28 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-04-18 |
Time |
09:35 |
Sent To |
|
|
| Notes |
| 2016-04-27 06:02:24 | 1) ) SHT. A3.23 - ACCESSIBLE ROLL-IN SHOWER WITH GRAB | | | BAR AND SEAT DETAIL SH 3 - THIS IS CONSIDERED AS AN | | | ALTERNATE ROLL-IN SHOWER DUE TO THE SIZE (36 X 60 | | | INCHES). THE LOCATION OF THE SHOWER SEAT SHALL COMPLY | | | WITH THE 2014 FBC-ACCESSIBILITY SEC.610.3 AND THE | | | LOCATION OF THE SHOWER CONTROLS SHALL COMPLY | | | FBC-ACCESSIBILITY SEC.608.5.3.PROVIDE DETAILS THAT SHOW | | | COMPLIANCE. | | | 2) DEFINE THE OCCUPANCY FOR THIS STRUCTURE. THE AMOUNT | | | OF COMBUSTIBLE/FLAMMABLE LIQUID STORAGE APPEARS TO | | | DEFINE THIS STRUCTURE AS AN "H" OCCUPANCY PER CHAPT. | | | 307.4, 307.5 & CHAPT. 4 OF THE 2014 FBC. PLEASE SUBMIT | | | A COPY OF THE LETTER FROM HOWE ENGINEERS DATED MARCH23, | | | 2016 PROVIDED IN A RESPONSE COMMENT TO WESLEY JOLIN | | | WHICH INDICATES THAT THE QUANTITIES OF THE VARIOUS | | | MATERIALS STORED DO NOT REQUIRE THE BUILDING TO BE | | | CONSIDERED AN "H" OCCUPANCY. I COULD NOT FIND THIS | | | LETTER IN THE SUPPRTING DOCUMENT FOLDER. SEE RESPONSE | | | TO PLUMBING PLAN REVIEW COMMENTS FROM HKS DATED APRIL | | | 14, 2016. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | | | | **** NOTE**** THE FOLLOWING COMMENTS ARE PROVISOS FOR | | | THE PLUMBING PLAN REVIEW ONLY. THE GAS PLAN REVIEW WILL | | | BE LISTED AS A SEPARATE REVIEW. THE PROVISOS SHALL BE | | | SATISFIED BY THE SUBMITTAL OF THE REQUIRED INFORMATION | | | PRIOR TO ANY PLUMBING INSPECTIONS BEING PERFORMED AT | | | THESE AREAS. TIM LARGE, CHIEF PLUMBING INSPECTOR. | | | 3) SHT.IR 1.07 - SUBMIT COMPLETE DETAILS FOR THE ACID | | | INJECTION SYSTEM FOR THE IRRIGATION SYSTEM, CONTAINMENT | | | SYSTEM, PUMPS,VALVES,PIPING, ETC. SHOW HOW THIS AREA | | | WILL BE PROTECTED AGAINST UNAUTHORIZED ENTRY. 2014 FBC | | | SEC.107.2.1. | | | 4) SUBMIT MSDS DATA FOR THE CHEMICALS TO BE USED FOR | | | THE ACID INJECTION SYSTEM FOR THE IRRIGATION SYSTEM. | | | 2014 FBC SEC.107.2.1. | | | 5) THE LAUNDRY AREAS IN THE CLUBHOUSES SHALL COMPLY | | | WITH THE 2014 FBC- ACCESSIBILITY SECS .611 & 309. ALL | | | WASHERS AND DRYERS SHALL COMPLY WITH THE REQUIREMENTS | | | FOR CLEAR FLOOR SPACE, OPERABLE PARTS, AND HEIGHT. | | | 6) SHT.P4.003 - APPROVAL IS REQUIRED FROM THE PALM | | | BEACH COUNTY DEPARTMENT OF ENVIRONMENTAL RESOURCE | | | PROTECTION FOR THE ABOVE GROUND FUEL STORAGE TANKS PER | | | PALM BEACH COUNTY ORDINANCE #2015-008. | | | 7) THE SANITARY AND WATER RISERS ARE INCOMPLETE AND | | | DEFICIENT AND A THOROUGH AND COMPREHENSIVE REVIEW COULD | | | NOT BE DONE AT THIS TIME. AS-BUILT SANITARY AND WATER | | | RISERS SHALL BE SUBMITTED DURING THE INSPECTION PROCESS | | | FOR THESE SYSTEMS. | | | 8) MANUFACTURER'S SPECIFICATIONS FOR THE FUEL | | | DISPENSERS, TANKS, VALVES, ETC. SHALL BE SUBMITTED FOR | | | REVIEW. 2014 FBC SEC.107.2.1. | | | 9) THE FUEL TANKS, DISPENSERS AND ALL ASSOCIATED PIPING | | | SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 30, 2012 | | | EDITION AS ADOPTED BY THE 2014 FBC. | | | 10) SUBMIT A CONDENSATE RISER FOR REVIEW. THE | | | CONDENSATE SHALL NOT DISCHARGE INTO THE SANITARY SYSTEM | | | OR THE GREASY WASTE SYSTEM PER THE CITY OF WEST PALM | | | BEACH CODE OF ORDINANCES AND 2014 FBC SEC.1003.2. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-03-10 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-03-10 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-02-27 |
Time |
10:20 |
Sent To |
|
|
| Notes |
| 2016-03-08 08:59:02 | 1) SHT.C9.21 - GREASE/WATER SEPARATOR DETAIL - THE CITY | | | DETAIL ON THE PLAN IS AN OUTDATED DETAIL. REFER TO | | | DETAIL GS 7 ISSUED IN 2015. | | | 2) SHT. IR1.07 - SUBMIT COMPLETE DETAILS FOR THE ACID | | | INJECTION SYSTEM FOR THE IRRIGATION SYSTEM, CONTAINMENT | | | SYSTEM, PUMPS, VALVES, PIPING, ETC. FBC 107.2.1. SHOW | | | HOW THIS AREA WILL BE PROTECTED AGAINST UNAUTHORIZED | | | ENTRY. | | | 3) SUBMIT MSDS DATA FOR THE CHEMICALS USED FOR THE ACID | | | INJECTION SYSTEM FOR THE IRRIGATION SYSTEM.FBC 107.2.1. | | | 4) SHT. A1.22 - DETAIL #2 - THE GUTTERS FOR THE BATTING | | | TUNNEL ROOF SHALL BE SIZED IN ACCORDANCE WITH TABLE | | | 1106.6 OF THE 2014 FL. PLUMBING CODE. CLEARLY THE | | | LOCATION OF ALL GUTTERS ON THE PLAN. | | | 5) THE ROOM FINISH PLAN ON SHT. A3.40 SHOWS THE WALLS | | | IN SOME OF THE RESTROOMS AND TOILET ROOMS AS PAINT. | | | 2014 FBC SEC. 1210.2.2 REQUIRES WALLS AND PARTITIONS | | | WITHIN 2 FEET OF SERVICE SINKS, URINALS AND WATER | | | CLOSETS TO HAVE A SMOOTH, HARD, NONABSORBENT SURFACE TO | | | A HEIGHT OF NOT LESS THAN 4 FEET ABOVE THE | | | FLOOR.EXCEPTION:TOILET ROOMS THAT ARE NOT ACCESSIBLE TO | | | THE PUBLIC AND WHICH HAVE NOT MORE THAN ONE WATER | | | CLOSET. | | | 6) SINKS LOCATED IN BREAK ROOM AREAS SHALL COMPLY WITH | | | THE 2014 FAC SEC.212 & 606. | | | 7) THE LAUNDRY AREAS SHALL COMPLY WITH THE 2014 FAC | | | SEC.611. | | | 8) SHT. A2.913 - DETAIL # 01 - THE WATER CLOSET SHALL | | | BE LOCATED DIAGONALLY OF THE COMPARTMENT DOOR PER 2014 | | | FAC SEC.604.8.1.2. | | | 9) SHT. A2.914 - DETAILS # 3 & #4 - THE DOOR SHALL BE | | | LOCATED PER FAC SEC.604.8.1.2. | | | 10) SHT.A3.23 - DETAIL EWC 3 - THE SPOUT ON THE HIGH | | | SIDE DRINKING FOUNTAIN SHALL BE LOCATED 38-43 INCHES | | | ABOVE THE FINISH FLOOR OR GROUND PER THE FAC SEC.602.7. | | | 11) SHT.A#.23 - ACCESSIBLE ROLL IN SHOWER WITH GRAB BAR | | | AND SEAT - THIS IS CONSIDERED AN ALTERNATE ROLL- IN | | | TYPE SHOWER DUE TO THE SIZE (36" X 60") AND THE | | | LOCATION OF THE SHOWER SEAT SHALL COMPLY WITH THE 2014 | | | FAC SEC.610.3 AND THE LOCATION OF THE CONTROLS SHALL | | | COMPLY WITH SEC.608.5.3. | | | 12) SHT. A3.23 - ACCESSIBLE SHOWER TRANSFER - THE | | | CONTROLS SHALL BE A MINIMUM OF 38 INCHES AND A MAXIMUM | | | OF 48 INCHES ABOVE THE SHOWER FLOOR AND SHALL BE | | | LOCATED ON THE CONTROL WALL 15 INCHES MAXIMUM FROM THE | | | CENTERLINE OF THE SEAT TOWARD THE SHOWER OPENING. FAC | | | SEC.608.5.1. | | | 13) TOILET PAPER DISPENSERS IN THE ACCESSIBLE TOILET | | | ROOMS/COMPARTMENTS SHALL BE LOCATED A MINIMUM OF 7 | | | INCHES AND A MAXIMUM OF 9 INCHES IN FRONT OF THE WATER | | | CLOSET MEASURED TO THE CENTERLINE OF THE DISPENSER. FAC | | | SEC.604.7. | | | 14) SHT. A8.21 - ALL NEWLY INSTALLED UNDERGROUND | | | HYDRAULIC PRESSURE CYLINDERS SHALL BE ENCASED IN OUTER | | | PLASTIC CONTAINMENT TO MINIMIZE ELECTROLYTIC CORROSION | | | BETWEEN THE METAL CYLINDER AND GROUND CATHODE. 2014 FBC | | | SEC.3011.1. | | | 15) SHT. P0.03 - THE PLUMBING FIXTURE SCHEDULE SHOWS | | | LAVATORY FAUCETS 2B & 2C WITH COLD WATER ONLY. HOT OR | | | TEMPERED SHALL BE SUPPLIED TO THE LAVATORIES PER FPC | | | SEC.607.1.THE WATER RISERS SHALL CLEARLY SHOW | | | HOT/TEMPERED WATER TO THE REQUIRED FIXTURES. | | | 16) SHT. P2.001, 002 & 003 - THE OVERALL PLANS ARE | | | PEPPERED WITH DARK MARKS AND ARE IMPOSSIBLE TO SEE WHAT | | | THEY REPRESENT. CLARIFY. | | | 17) SHT. P2.114 - THERE IS A GREASY WASTE LINE THAT | | | APPEARS TO BE ALSO LABELED AS A SANITARY LINE.SEE AREA | | | BETWEEN GRID LINES S17 & S18 AND SG & SH. PLEASE CHECK | | | ALL SHEETS TO ENSURE THE DRAINAGE LINES ARE PROPERLY | | | LABELED. | | | 18) SHT.P4.003 - APPROVAL IS REQUIRED FROM THE PALM | | | BEACH COUNTY DEPT. OF ENVIRONMENTAL RESOURCE PROTECTION | | | FOR THE ABOVE GROUND FUEL STORAGE TANKS. PBC ORD. # | | | 2015 - 008. | | | 19) SHT. P4.003 - THE FUELING SCHEMATIC REFERS TO | | | SEVERAL DETAILS ( A,B,C, ETC.) WHERE ARE THESE DETAILS? | | | CLARIFY. | | | 20) SHT.P4.003 - NUMBERED NOTE #1 REFERS TO A ONE | | | THOUSAND GALLON DIVIDED FUEL TANK BUT THE FUELING | | | SYSTEM SCHEMATIC SHOWS A DIVIDED 2500 GALLON TANK. | | | CLARIFY. | | | 21) THE SANITARY AND WATER RISERS ARE INCOMPLETE AND | | | DEFICIENT AND A THOROUGH AND COMPREHENSIVE REVIEW COULD | | | NOT BE DONE AT THIS TIME. AS-BUILT SANITARY AND WATER | | | RISERS WILL BE SUBMITTED DURING THE INSPECTION PROCESS. | | | 22) PLACE THE ROOM NUMBERS ON THE ENLARGED PLANS. IT IS | | | DIFFICULT TO LOCATE THESE AREAS ON THE PLAN VIEW | | | LAYOUT. FBC 107.2.1. | | | 23) SAMPLING PORTS ARE REQUIRED ON THE DISCHARGE SIDE | | | OF EACH GREASE INTERCEPTOR PER THE CWPB STANDARD | | | DRAWING GS-7.1. | | | 24) SUBMIT MANUF. SPECIFICATIONS FOR THE RETROCEPTOR | | | SHOWN IN THE STADIUM SUITE LEVEL PARTY DECK. | | | 25) SHT. S5.101.5 - THERE ARE NUMBERED NOTE TAGS ON THE | | | RISER DIAGRAM BUT THERE ARE NO NUMBERED NOTES ON THE | | | DRAWING. CLARIFY. | | | 26) SHT.P5.401 - THE SHEET DRAWING NUMBERS THAT SHOW | | | THE CONTINUATION OF THE FUEL GAS SYSTEM ARE ILLEGIBLE . | | | SUBMIT A PLAN THAT CLEARLY SHOWS THE SHEET DRAWING | | | NUMBERS. FBC 107.2.1. | | | 27) CLEARLY SHOW THE LOCATION OF ALL MEDIUM PRESSURE | | | GAS REGULATORS ON THE GAS RISERS. FBC 107.2.1. | | | 28) CLEARLY SHOW THE PIPE SIZES OF THE PIPING | | | DOWNSTREAM OF THE MP REGULATOR.FBC 107.2.1. | | | 29) SIZE ALL SECTIONS OF THE PIPING ON ALL GAS | | | RISERS.FBC 107.2.1. | | | 30) IDENTIFY THE GAS METER ON THE GAS RISER ON | | | SHT.P5.401. | | | 31) IDENTIFY EACH PIECE OF GAS EQUIPMENT ON THE GAS | | | RISER AND THE BTU LOAD FOR EACH PICE OF | | | EQUIPMENT/APPLIANCE.FBC 107.2.1. | | | 31) SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE 2014 | | | FBC-FUEL GAS CODE SEC.304.1. | | | 32) SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE | | | AND TERMINATION OF THE GAS VENTS PER 2014 FBC-FUEL GAS | | | SECS. 502 THRU 505. | | | 33) ALL EQUIPMENT SHALL BE LISTED AND LABELED IN | | | ACCORDANCE WITH 2014 FGC SEC.301.3. | | | 34) SHT. P5.401 - MEP EQUIPMENT SCHEDULE SHOWS THE | | | GWH-2 AS 1950 MBH BUT SHEET P5.401.1 APPEARS TO SHOW | | | GWH-2 WITH LESS BTU'S. CLARIFY. | | | 35) SHT. P5.401.3 - SUBMIT AN EXPANDED GAS RISER | | | DIAGRAM FOR THE WATER HEATERS AND SHOW THE REGULATOR. | | | IT IS IMPOSSIBLE TO SEE WHERE THE MEDIUM PRESSURE AND | | | LOW PRESSURE PIPING BEGINS AND ENDS. | | | 36) THE FOLLOWING COMMENTS ARE ALL FOR SHT. P5.402 - | | | THE 2" MEP LINE IS UNDERSIZED.TABLE 402.4 (5) LIMITS A | | | 2' LINE TO 2010MBH.THE DRAWING SHOWS A BTU LOAD FROM | | | 2010 MBH UP TO 3030 MBH. | | | 37) THE 1 1/4 " LINE WITH 700MBH IS UNDERSIZED.MAXIMUM | | | ALLOWED BY TABLE 402.4 (5) IS 695 MBH. THE LINE SHALL | | | BE 1 1/2" MINIMUM. | | | 38) THE 1" MEDIUM PRESSURE LINE WITH 440 MBH IS | | | UNDERSIZED. MAXIMUM IS 339MBH.THE LINE SHALL BE 1 1/4". | | | 39) THE 1 1/2" MEDIUM PRESSURE LINE CARRYING 1640MBH | | | NEEDS TO BE 2" PER TABLE 402.4 (5). | | | 40) THE 1 1/2" MEDIUM PRESSURE LINE CARRYING 1440 MBH | | | NEEDS TO BE 2". | | | 41) THE 1"MP LINE CARRYING 440 MBH NEEDS TO BE 1 1/4". | | | 42) SHT. P5.402.1 - THE FOLLOWING COMMENTS ARE ALL | | | APPLICABLE TO SHT.P5.402.1. | | | 43) THE 1 1/4" MP LINE CARRYING 700 MBH IS UNDERSIZED. | | | IT NEEDS TO BE 1 1/2". | | | 44) THE 1" MP & LOW PRESSURE LINE CARRYING 440 MBH IS | | | UNDERSIZED. BOTH LINES NEED TO BE 1 1/4". | | | 45) THE 3/4" MP LINE CARRYING 300 MBH IS UNDERSIZED. IT | | | NEEDS TO BE 1". THE LOW PRESSURE SAID NEEDS TO BE 1 | | | 1/4". | | | 46) THE 1 1/2" MP LINE CARRYING 1440 MBH IS UNDERSIZED. | | | IT NEEDS TO BE 2". TABLE 402.4 (5). | | | 47) THE 1 1/2" MP LINE CARRYING 1640MBH IS UNDERSIZED. | | | IT NEEDS TO BE 2". TABLE 402.4 (5). | | | 48)SHT. P5.402.2. - THE FOLLOWING COMMENTS ARE ALL | | | APPLICABLE TO SHT. P5.402.2. - | | | 49) THE 1 1/2" MP LINE CARRYING 1640MBH IS UNDERSIZED. | | | IT NEEDS TO BE 2". | | | 50) THE 2" MP LINE CARRYING 2080MBH IS UNDERSIZED. IT | | | NEEDS TO BE 2 1/2". TABLE 402.4 (5). | | | 51) THE 1" MP LINE CARRYING 440MBH IS UNDERSIZED. IT | | | NEEDS TO BE 1 1/4". | | | 52) THE 2" MP LINE CARRYING 2130 IS UNDERSIZED. IT | | | NEEDS TO BE 2 1/2". | | | 53) THE 1 1/4" LOW PRESSURE LINE CARRYING 700MBH IS | | | UNDERSIZED. IT NEEDS TO BE 1 1/2". | | | 54) THE 2" MP LINE CARRYING 3030MBH IS UNDERSIZED.IT | | | NEEDS TO BE 2 1/2". | | | 55) THE 3" MP LINE CARRYING 6930MBH IS UNDERSIZED. IT | | | NEEDS TO BE 4". | | | 56) THE 2 1/2" MP LINE CARRYING 3900 IS UNDERSIZED. IT | | | NEEDS TO BE 3". | | | 57) THE 2" LOW PRESSURE LINE CARRYING 1950MBH IS | | | UNDERSIZED. IT NEEDS TO BE 2 1/2'. | | | 58) THE FOLLOWING COMMENTS ARE ALL APPLICABLE TO | | | SHT.P5.403. | | | 59) PROVIDE THE TEXT FOR NUMBERED NOTE #1. | | | 60) THE 1" MP LINE CARRYING 500MBH IS UNDERSIZED. IT | | | NEEDS TO BE 1 1/4". | | | 61) THE 1 1/2" MP LINE CARRYING 1320MBH IS UNDERSIZED. | | | IT NEEDS TO BE 2". | | | 62) THE 1 1/4"MP LINE CARRYING 700MBH IS UNDERSIZED. IT | | | NEEDS TO BE 1 1/2". | | | 63) THE 2" MP LINE CARRYING 2020MBH, 2220MBH, AND 2320 | | | MBH IS UNDERSIZED. IT NEEDS TO BE 2 1/2". | | | 64) THE 3/4" MP LINE CARRYING 200MBH IS UNDERSIZED. IT | | | NEEDS TO BE 1". | | | 65) THE 1 1/2" MP LINE CARRYING 1320MBH IS UNDERSIZED. | | | IT NEEDS TO BE 2". | | | 66) THE 3" MP LINE CARRYING 6970 MBH IS UNDERSIZED. IT | | | NEEDS TO BE 4". | | | 67) THE 2 1/2" MP LINE CARRYING 3900MBH IS UNDERSIZED. | | | IT NEEDS TO BE 3". | | | 68) SHT.P5.403.1 - CHECK THE ENTIRE RISER FOR CORRECT | | | SIZING AND COMPLY WITH 2014 FGC TABLES 402.4 (1) AND | | | 402.4 (5). THE RISER IS UNDERSIZED FOR THE BTU LOAD. | | | 69) SHT. P5.403.2 - CHECK THE ENTIRE RISER FOR CORRECT | | | SIZING AND COMPLY WITH 2014 FGC TABLES 402.4 (1) AND | | | 402.4 (5). THE RISER IS UNDERSIZED FOR THE BTU LOAD. | | | 70) SHT.P4.003 - SUBMIT A LEGEND FOR ALL THE COMPONENT | | | TAGS THAT ARE SHOWN ON THE PLAN. FBC 107.2.1. | | | 71) INDICATE THE LIQUID CLASS FOR THE GASOLINE ON THE | | | PLANS IN ACCORDANCE WITH CHAPT.2 OF 2014 FBC. | | | 72) MANUFACTURER'S SPECIFICATIONS FOR DISPENSERS, | | | TANKS, VALVES, ETC. SHALL BE SUBMITTED FOR REVIEW. THE | | | DOCUMENTS CAN BE SUBMITTED NOW OR BE A DEFERRED | | | SUBMITTAL IN ACCORDANCE WITH FBC 107.3.4.2. | | | 73) DEFINE THE OCCUPANCY FOR THIS STRUCTURE. THE AMOUNT | | | OF COMBUSTIBLE/FLAMMABLE LIQUID STORAGE APPEARS TO | | | DEFINE THIS STRUCTURE AS AN "H" OCCUPANCY PER CHAPT. | | | 307.4, 307.5 & CHAPT. 4 OF THE 2014 FBC. | | | 74) THE TANKS,DISPENSERS AND ALL ASSOCIATED PIPING AND | | | CONSTRUCTION OF THE ENCLOSURE SHALL COMPLY WITH NFPA 30 | | | AND 2014 FBC. | | | 75) SUBMIT A CONDENSATE RISER FOR REVIEW. THE | | | CONDENSATE SHALL NOT DISCHARGE TO THE SANITARY PER CITY | | | ORDINANCE OR TO THE GREASY WASTE SYSTEM. 2014 FBC SEC. | | | 1003.2. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
P |
Date |
2016-05-24 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-05-24 |
Time |
08:58 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-05-24 |
Time |
08:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2016-05-23 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2016-05-23 |
Time |
17:07 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2016-05-23 |
Time |
17:07 |
Sent To |
|
|
| Notes |
| 2016-05-23 17:09:43 | 5/23/16- PASSED WITH THE PROVISO THAT SEPARATE PERMITS | | | ARE REQUIRED FOR FENCING, LIGHT POLES, SIGTGNAGE, | | | LANDSCAPING, HARDSCAPE (PUBLIC PATHS) AND IRRIGATION. | | | | | | ANGELLA VANN | | | 561-822-1441 | | | [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2016-04-21 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2016-04-21 |
Time |
18:03 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2016-04-21 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2016-04-21 18:01:42 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | | | 4/21/16 | | | | | | 1. [PREVIOUS COMMENT #1] THERE APPEARS TO BE MORE THAN | | | ONE SITE PLAN SUBMITTED - SP0.01, C2.01 AND A1-00 | | | DEPICTING DIFFERENT AMOUNTS OF INFORMATION. THE | | | SUBMITTED SITE PLANS ARE EITHER NOT COMPLETE OR DO NOT | | | REPRESENT CHANGES MADE TO THE SINCE CITY COMMISSION | | | APPROVAL. PLEASE INCLUDE A COPY OF THE MINOR PD | | | AMENDMENT SITE PLAN WHICH WILL ADDRESS THIS COMMENT AND | | | THE FOLLOWING PREVIOUS COMMENTS: | | | A. INCLUDE ALL SITE DATA AND CALCULATIONS. THIS | | | INFORMATION WILL NEED TO BE UPDATED TO REFLECT ANY | | | CHANGES TO THE SITE PLAN. | | | B. BUBBLE ALL CHANGES ON THE SITE PLAN. | | | C. PROVIDE LABELS FOR ITEMS ON THE PLAN (I.E. COVERED | | | BATTING TUNNELS, POOL, DUGOUT, ETC.). | | | D. INCLUDE DIMENSIONS, SETBACKS, ETC. TO DEMONSTRATION | | | COMPLIANCE OR DEVIATIONS FROM THE APPROVED SITE PLAN. | | | | | | 2. SHEET C9.01 - CORRECT STRIPING DETAIL FOR ADA SPACE | | | TO SHOWN DOUBLE STRIPED LINES CONNECTED AT THE BOTTOM. | | | WHERE ON THE PLANS ARE THE REGULAR PARKING SPACE WIDTHS | | | INDICATED. STRIPING DETAIL INDICATES 'STALL WIDTH', BUT | | | NO DIMENSION INDICATED. | | | | | | GENERAL COMMENTS: | | | | | | 3. SHEET L3.08 - DETAIL 2 FOR PLAZA BIKE RACK - BASED | | | ON MINIMUM SPACING (2.5 FEET BETWEEN RACKS, 2 FEET | | | BETWEEN END RACK AND EDGE OF PAD), PROPOSED 12 RACKS, | | | AND WIDTH OF EACH RACK BEING 3 INCHES, THE PAD DEPTH ON | | | THE DETAIL NEEDS TO BE A MINIMUM OF 34.5 FEET. A NOTE | | | HAS BEEN ADDED TO THE PLAN BUT SHOULD BE CORRECTED WITH | | | A RESUBMITTAL. | | | | | | 4. SHEET A7.06 - ENTRY LOGO SCULPTURES WILL NEED TO BE | | | PERMITTED UNDER A SEPARATE PERMIT. PLEASE NOTE THAT | | | ADDITIONAL REVIEW WILL BE REQUIRED BASED ON THE SIGNAGE | | | REGULATIONS AND PLACEMENT. THE PROPOSED LOCATION OF | | | NATIONAL ENTRY LOGO SPANS OVER A SIDEWALK AND 3 OF THE | | | 6 PROPOSED UPLIGHTS ARE ALSO LOCATED ON THE SIDEWALK. | | | NOTE HAS BEEN ADDED TO THE PLANS. | | | | | | 5. SEPARATE PERMITS REQUIRED FOR FENCING, LIGHT POLES, | | | SIGNAGE, LANDSCAPING, AND IRRIGATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2016-03-08 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2016-03-08 |
Time |
17:34 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2016-02-26 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2016-03-10 13:17:16 | PLANNING AND ZONING COMMENTS **UPDATE** | | | | | | 3/10/16 | | | | | | IN FOLLOW-UP TO COMMENT #7, THE PROPOSED CAPITOL BIKE | | | RACK WILL NOT BE AN ACCEPTED MODEL FOR USE AS IT LACKS | | | TWO POINTS OF SUPPORT AND HAS LIMITED ABILITY TO HANDLE | | | A MIX OF BICYCLE LOCKING MECHANISMS. IF OBLIGATED TO | | | USE A BICYCLE RACK MODEL PROVIDED BY FORMS + SURFACES, | | | THE FOLLOWING MODELS WILL BE ACCEPTED - TRIO BIKE RACK, | | | CORDIA BIKE RACK, SUMMIT BIKE RACK, AND TWIST BIKE | | | RACK. OTHERWISE, YOU CAN ALSO WORK WITH ANOTHER VENDOR | | | TO PROVIDE AN ACCEPTABLE MODEL. | | | | | | | | 2016-03-08 17:37:27 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | | | 3/8/16 | | | | | | 1. THERE APPEARS TO BE MORE THAN ONE SITE PLAN | | | SUBMITTED ? C2.01 AND A1-00 DEPICTING DIFFERENT AMOUNTS | | | OF INFORMATION. THE SUBMITTED SITE PLAN IS NOT COMPLETE | | | AND THE FOLLOWING MUST BE ADDRESSED: | | | A. INCLUDE ALL SITE DATA AND CALCULATIONS. THIS | | | INFORMATION WILL NEED TO BE UPDATED TO REFLECT ANY | | | CHANGES TO THE SITE PLAN. | | | B. BUBBLE ALL CHANGES ON THE SITE PLAN. | | | C. PROVIDE LABELS FOR ITEMS ON THE PLAN (I.E. COVERED | | | BATTING TUNNELS, POOL, DUGOUT, ETC.). | | | D. INCLUDE DIMENSIONS, SETBACKS, ETC. TO DEMONSTRATION | | | COMPLIANCE OR DEVIATIONS FROM THE APPROVED SITE PLAN. | | | E. THE HARDSCAPE PLAN SHOWS CHANGES TO FENCE HEIGHTS | | | AND LOCATIONS WHICH WILL ALSO NEED TO BE UPDATED ON THE | | | MASTER SITE PLAN. ADDITIONALLY IT IS DIFFICULT TO | | | LOCATE 4 FOOT FENCE TYPE ON HARDSCAPE PLAN L3.00 THRU | | | L3.06. | | | | | | 2. A MINOR PD AMENDMENT IS REQUIRED FOR ALL CHANGES | | | FROM THE APPROVED SITE PLAN. THE MINOR PD AMENDMENT | | | SUBMITTAL NEEDS TO HAVE CALCULATIONS DEMONSTRATING THAT | | | NONE OF THE MAJOR PD AMENDMENT THRESHOLDS IN RES. | | | 205-15 ARE EXCEEDED. | | | | | | 3. SHEET 7.04 SHOWS THERE IS NO LONGER A 5 FOOT | | | LANDSCAPE ISLAND NEXT TO THE SOUTHEASTERN MOST PARKING | | | SPACE BECAUSE THE LIFT STATION APPEARS TO HAVE BEEN | | | ENLARGED. PLEASE CONFIRM CONFLICTS WITH THE SITE PLAN. | | | A MINIMUM 5 FOOT LANDSCAPE ISLAND WILL BE REQUIRED. | | | | | | 4. SHEET 9.01 - CORRECT STRIPING DETAIL TO PROVIDE 4" | | | DOUBLE STRIPES, SEPARATED BY 12", AND CONNECTED AT THE | | | BOTTOM [ZLDR SEC. 94-485, STALL PAINING DETAIL]. SINGLE | | | STRIPED PARKING SPACES IS NOT PERMITTED. | | | | | | 5. SHEET L3.00 - PLEASE NOTE THAT THE COLOR CHOSEN ON | | | THE HARDSCAPE PLAN TO REPRESENT THE CRUSHED GRAVEL | | | PATHWAY IS A VERY SIMILAR IN COLOR TO THE PAVED PARKING | | | AREAS. PLEASE PROVIDE ANOTHER COLOR OR SYMBOL TO | | | DISTINGUISH THE DIFFERENCE BETWEEN THE CRUSHED GRAVEL | | | PATHWAY AND PAVED PARKING AREAS. | | | | | | 6. SHEET L3.08 - DETAIL 1 FOR STANDARD BIKE RACK DETAIL | | | - THE BICYCLE RACK SPACING DIMENSIONS ARE FROM THE RACK | | | ITSELF AND NOT THE CENTER OF THE RACK. PLEASE ACCOUNT | | | FOR WIDTH OF RACKS IN OVERALL WIDTH OF THE BICYCLE | | | PARKING PADS TO ENSURE 2.5 FEET CAN BE PROVIDED BETWEEN | | | RACKS AND 2 FEET FROM THE END RACK TO EDGE OF PAD. | | | ADJUST SIZES ON SITE PLAN AS NECESSARY. | | | | | | 7. SHEET L3.08 - DETAIL 2 FOR CAPITOL BIKE RACK - THIS | | | MODEL IS UNDER REVIEW AS AN ACCEPTABLE BICYCLE RACK | | | STYLE FOR USE IN THE CITY. IF APPROVED, PROVIDE A | | | SPACING DETAIL FOR THE BICYCLE RACKS TO DEMONSTRATE A | | | MINIMUM 2.5 FEET BETWEEN RACKS, 2 FEET BETWEEN END RACK | | | AND EDGE OF PAD, AND 6 FEET MINIMUM LENGTH FOR THE | | | PARKING PAD. | | | | | | 8. PLEASE REVIEW ALL PLANS FOR CONSISTENCY WITH BICYCLE | | | PARKING LOCATIONS. FOR EXAMPLE, PLAZA PARKING IS | | | DEPICTED DIFFERENTLY IN SHEETS L3.03 AND L4.04. | | | | | | 9. ALL EQUIPMENT CORRALS MUST BE SCREENED IN ACCORDANCE | | | WITH ZLDR SEC. 94-444(B) AND (C). WINDSCREENS ON A | | | CHAIN-LINK FENCE IS NOT SUFFICIENT. | | | | | | 10. SHEET A7.06 - ENTRY LOGO SCULPTURES WILL NEED TO BE | | | PERMITTED UNDER A SEPARATE PERMIT. PLEASE NOTE THAT | | | ADDITIONAL REVIEW WILL BE REQUIRED BASED ON THE SIGNAGE | | | REGULATIONS AND PLACEMENT. THE PROPOSED LOCATION OF | | | NATIONAL ENTRY LOGO SPANS OVER A SIDEWALK AND 3 OF THE | | | 6 PROPOSED UPLIGHTS ARE ALSO LOCATED ON THE SIDEWALK. | | | | | | 11. SHEET E1-00-3, SHEET E1-00-4 - THERE ARE WALL | | | MOUNTED JUNCTION BOXES WITHIN THE SETBACK. HOW HIGH ARE | | | THESE JUNCTION BOXES MOUNTED? | | | | | | 12. SEPARATE PERMITS REQUIRED FOR FENCING, LIGHT POLES, | | | SIGNAGE, LANDSCAPING, AND IRRIGATION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |