| Plan Review Stops For Permit 16020238 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2017-01-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-01-12 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-01-12 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2017-01-12 15:34:24 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | 1- REVISE ENERGY CALCULATIONS SUBMITTED: | | | A) REVISE THE BUILDING ORIENTATION OF THE WALLS, DOORS | | | AND WINDOWS ON PAGE 3 OF 4. SEE SURVEY AND PROVIDE | | | ACTUAL ORIENTATION. | | | B) REVISE THE WINDOWS OVERHANG DEPTH AND SEPARATION | | | SHOWN ON PAGE 3 OF 4 TO MATCH PLANS. NOTE: SEE GABLE | | | END WALLS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2016-12-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-12-07 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-12-07 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2016-12-07 12:28:39 | | | | MAIN HOUSE: | | | RESIDENTIAL (R3) ALTERATIONS THIRD BUILDING REVIEW | | | CHECKLIST. | | | CODE: FBC-5TH EDITION (2014). | | | | | | | | | NOTE: | | | ENGINEER OF RECORD MAY BE CHARGED FOUR TIMES THE PLAN | | | REVIEW FEE IF PLANS ARE DENIED THREE OR MORE TIMES AS | | | REQUIRED BY FLORIDA STATUTE 553.80(2)(B). | | | | | | | | | 1- REVISE ENERGY CALCULATIONS SUBMITTED: | | | A) ENERGY CALCULATIONS AND A/C EQUIPMENT SIZING | | | CALCULATIONS NEED TO BE COORDINATED. SEE EQUIPMENT | | | SIZING CALCULATIONS FOR COOLING AND HEATING LOADS AND | | | REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC-ENERGY | | | CONSERVATION, 5TH EDITION (2014). | | | | | | B) PROVIDE COMPLETE INFORMATION ON TOP OF FORM. SEC. | | | R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION | | | (2014). | | | RESPONSE: MISSING THE OWNER INFORMATION (REPEAT | | | COMMENT). | | | | | | C) ITEM #1 IS INCORRECT. THIS IS NOT NEW CONSTRUCTION. | | | REVISE AS REQUIRED. | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL. | | | | | | D) PROVIDE MANUFACTURER'S INFORMATION FOR THE WINDOWS | | | AND DOORS SHOWING COMPLIANCE WITH THE U-FACTOR AND SHGC | | | FACTOR SPECIFIED ON THE ENERGY CALCULATIONS ON ITEM #7. | | | NOTE: THIS IS ONLY REQUIRED WHEN THE PERSON PREPARING | | | THE CALCULATIONS IS TAKING A FACTOR OTHER THAN THE | | | DEFAULT FACTOR OF THE ENERGY CALCULATIONS SOFTWARE. | | | SEC. R405.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION | | | (2014). | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. | | | | | | E) REVISE ITEM #10 R-30 INSULATION DOESN'T FIT ON 2X8 | | | ROOF JOIST. SEE PLANS AND REVISE AS REQUIRED. SEC. | | | R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION | | | (2014). | | | RESPONSE: REPEAT COMMENT. R-30 INSULATION DOESN'T FIT. | | | R-30 BUTT INSULATION IS +/- 9-1/2" THICK AND NEED A | | | MINIMUM OF 1 INCH SPACE BETWEEN THE INSULATION AND THE | | | ROOF SHEATHING FOR CROSS VENTILATION. TYPICAL WALL | | | SECTION ON SHEET "B" SPECIFIES ADDITIONAL L 2X2 | | | MAILERS. THE ADDITION OF THESE MAILERS STILL DON'T | | | PROVIDE ENOUGH ROOM FOR THE R-30 INSULATION AND | | | REQUIRED 1" VENTING SPACE. REVISE AS REQUIRED. | | | | | | F) REVISE TYPE OF ROOF SPECIFIED ON PAGE 2 OF 4. | | | ACCORDING TO PLANS SUBMITTED THIS IS NOT A HIP ROOF. | | | SEE PLANS AND REVISE AS REQUIRED. SEC. R101.5.1.1.2 | | | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | | RESPONSE: REPEAT COMMENT. THE PERSON PREPARING THE | | | CALCULATIONS NEED TO REVISE THE INFORMATION. HAND | | | WRITTEN CHANGES ARE NOT ALLOWED. INFORMATION NEEDS TO | | | BE CHANGED ON THE SOFTWARE INPUT NOT BY HAND. REVISE AS | | | REQUIRED. | | | | | | G) REVISE INSULATION TYPE SHOWN ON THE CEILING | | | INFORMATION ON PAGE 2 OF 4. ACCORDING TO PLANS | | | SUBMITTED THERE IS NOT BLOWN INSULATION. SEE PLANS AND | | | REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC-ENERGY | | | CONSERVATION, 5TH EDITION (2014). | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL. | | | | | | H) SPECIFY THE BUILDING ORIENTATION OF THE WALLS, DOORS | | | AND WINDOWS ON PAGE 3 OF 4. SEC. R101.5.1.1.2 | | | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL. | | | | | | I) REVISE THE WINDOWS OVERHANG DEPTH AND SEPARATION | | | SHOWN ON PAGE 3 OF 4 TO MATCH PLANS. SEE PLANS AND | | | REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC-ENERGY | | | CONSERVATION, 5TH EDITION (2014). | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED AT ALL. | | | | | | 2- GABLE END SECTION ON SHEET "B": | | | A) SPECIFY ALL THE STRUCTURAL CONNECTORS ON THE GABLE | | | WALL FRAMING DETAIL. SEC. R601.2 AND R801.2 OF | | | FBC-RESIDENTIAL, 5TH EDITION (2014). | | | RESPONSE: REPEAT COMMENT. IT'S NOT CLEAR HOW THE | | | SIMPSON H10A CONNECTOR IS INSTALLED AT THE BOTTOM OF | | | THE 2X4 STUDS. ALSO, HOW IS THE METAL CONNECTOR #2 (SEE | | | METAL CONNECTOR SCHEDULE) IS INSTALLED. #2 CONNECTOR IS | | | TO BE EMBEDDED IN CONCRETE. THIS IS AN EXISTING | | | CONCRETE BEAM. HOW IS IT EMBEDDED IN THE EXISTING BEAM | | | AND CLARIFY HOW IS THIS #2 CONNECTOR INSTALLED AT TOP | | | OF THE 2X4 STUD. THERE IS NO WAY TO EMBED THIS | | | CONNECTOR IN WOOD FRAMING. | | | | | | B) INFORMATION SHOWN AT THE ROOF JOIST SECTION IS NOT | | | LEGIBLE. THE BACKGROUND DOESN'T ALLOW LETTERING TO BE | | | READ. REVISE AS REQUIRED. SEC. 107.2.1.4 CITY | | | AMENDMENTS. | | | RESPONSE: REPEAT COMMENT. | | | | | | C) R-30 BATT INSULATION DOESN'T FIT ON THE SIZE OF ROOF | | | JOIST SPECIFIED. REVISE AS REQUIRED. SEC. 107.2.1 CITY | | | AMENDMENTS. | | | RESPONSE: REPEAT COMMENT. SEE COMMENT #1(E) ABOVE. | | | | | | 3- WINDOW DETAILS ON SHEET "B": SPECIFY ALL CONNECTORS | | | OF THE WOOD FRAMING MEMBERS ON THE HEAD DETAIL. SEC. | | | R301.1 FBC-RESIDENTIAL. | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. | | | | | | 4- SHEET "A": | | | A) CLARIFY STRUCTURAL NOTES BELOW THE "DESIGN | | | STANDARDS". TYPICALLY, SPECIFICATIONS FOR THE | | | ATTACHMENT OF DOORS AND WINDOWS TO THE SUBSTRATE ARE | | | INCLUDED IN THE PRODUCT APPROVALS. WHAT ARE THESE NOTES | | | FOR?. IS THE ENGINEER OF RECORD CHANGING THE PRODUCT | | | APPROVAL SPECIFICATIONS? IF SO, THEN COMPLETE | | | ENGINEERING ANALYSIS IS REQUIRED. SEC. R301.1 | | | FBC-RESIDENTIAL. | | | RESPONSE: REPEAT COMMENT. NOT ADDRESSED. | | | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-11-18 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-11-18 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-11-17 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2016-11-17 16:31:45 | | | | MAIN HOUSE: | | | RESIDENTIAL (R3) ALTERATIONS SECOND BUILDING REVIEW | | | CHECKLIST. | | | CODE: FBC-5TH EDITION (2014). | | | | | | 1- REVISE ENERGY CALCULATIONS SUBMITTED: | | | A) PROVIDE COMPLETE INFORMATION ON TOP OF FORM, | | | INCLUDING OWNER NAME, BUILDER NAME, PERMIT OFFICE AND | | | JURISDICTION NUMBER. SEC. R101.5.1.1.2 FBC-ENERGY | | | CONSERVATION, 5TH EDITION (2014). | | | | | | B) ITEM #1 IS INCORRECT. THIS IS NOT NEW CONSTRUCTION. | | | REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC-ENERGY | | | CONSERVATION, 5TH EDITION (2014). | | | | | | C) PROVIDE MANUFACTURER'S INFORMATION FOR THE WINDOWS | | | AND DOORS SHOWING COMPLIANCE WITH THE U-FACTOR AND SHGC | | | FACTOR SPECIFIED ON THE ENERGY CALCULATIONS ON ITEM #7. | | | NOTE: THIS IS REQUIRED WHEN THE PERSON PREPARING THE | | | CALCULATIONS IS TAKING A FACTOR OTHER THAN THE DEFAULT | | | FACTOR OF THE ENERGY CALCULATIONS SOFTWARE. | | | SEC. R405.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION | | | (2014). | | | | | | D) REVISE ITEM #10 R-30 INSULATION DOESN'T FIT ON 2X8 | | | ROOF JOIST. SEE PLANS AND REVISE AS REQUIRED. SEC. | | | R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION | | | (2014). | | | | | | E) OWNER/AGENT TO CERTIFY AND DATE BOTTOM OF FORM AS | | | REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION, | | | 5TH EDITION (2014). | | | | | | F) BUILDER TO COMPLETE THE EPL DISPLAY CARD AS REQUIRED | | | BY SEC. R405.4.3 FBC-ENERGY CONSERVATION, 5TH EDITION | | | (2014). | | | | | | G) REVISE TYPE OF ROOF SPECIFIED ON PAGE 2 OF 4. | | | ACCORDING TO PLANS SUBMITTED THIS IS NOT A HIP ROOF. | | | SEE PLANS AND REVISE AS REQUIRED. SEC. R101.5.1.1.2 | | | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | | | | | H) REVISE INSULATION TYPE SHOWN ON THE CEILING | | | INFORMATION ON PAGE 2 OF 4. ACCORDING TO PLANS | | | SUBMITTED THERE IS NOT BLOWN INSULATION. SEE PLANS AND | | | REVISE AS REQUIRED. COORDINATE WITH ITEM #1(D) ABOVE. | | | SEC. R101.5.1.1.2 FBC-ENERGY CONSERVATION, 5TH EDITION | | | (2014). | | | | | | I) SPECIFY THE BUILDING ORIENTATION OF THE WALLS, DOORS | | | AND WINDOWS ON PAGE 3 OF 4. SEC. R101.5.1.1.2 | | | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | | | | | J) REVISE THE WINDOWS OVERHANG DEPTH AND SEPARATION | | | SHOWN ON PAGE 3 OF 4 TO MATCH PLANS. SEE PLANS AND | | | REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC-ENERGY | | | CONSERVATION, 5TH EDITION (2014). | | | | | | K) COMPLETE THE INSPECTION CHECKLIST (TABLE 402.4.1.1 | | | SUBMITTED) AS REQUIRED BY SEC. R405.4.2 FBC-ENERGY | | | CONSERVATION, 5TH EDITION (2014). | | | | | | | | | 2- PLANS SUBMITTED ARE NOT LEGIBLE. THERE IS TOO MUCH | | | OVERLAPPING BACKGROUND INFORMATION THAT DOESN'T ALLOW | | | PLANS AND LETTERING TO BE READ. REVISE AS REQUIRED. | | | SEC. 107.2.1.4 CITY AMENDMENTS. | | | | | | ORIGINAL COMMENT: | | | 3- SPECIFY ALL THE STRUCTURAL CONNECTORS ON THE TYPICAL | | | GABLE WALL FRAMING DETAIL. SEC. R601.2 AND R801.2 OF | | | FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | | | RESPONSE: | | | THERE ARE TWO DIFFERENT GABLE END DETAILS ON SHEET "B". | | | ONE SHOWS AN EXISTING CONCRETE BEAM AND THE OTHER ONE | | | SHOWS AN EXISTING WOOD BEAM. | | | A) GABLE END WITH EXISTING CONCRETE BEAM DETAIL: | | | (1) IT IS NOT CLEAR HOW THE SIMPSON H10A CONNECTOR IS | | | INSTALLED AT THE BOTTOM OF 2X4 STUD. PROVIDE DETAIL | | | SHOWING HOW THE SIMPSON H10A CONNECTOR IS INSTALLED AT | | | THE BOTTOM 2X4 STUD. SEC. R301.1 FBC-RESIDENTIAL. | | | | | | (2) INFORMATION SHOWN AT THE ROOF JOIST SECTION IS NOT | | | LEGIBLE. REVISE AS REQUIRED. SEC. 107.2.1.4 CITY | | | AMENDMENTS. | | | | | | (3) R-30 BATT INSULATION DOESN'T FIT ON THE SIZE OF | | | ROOF JOIST SPECIFIED. REVISE AS REQUIRED. SEC. 107.2.1 | | | CITY AMENDMENTS. | | | NOTE: REVISE INSULATION R-VALUE SHOWN ON THE TYPICAL | | | WALL SECTION ALSO. | | | | | | B) GABLE END WITH EXISTING WOOD BEAM DETAIL: | | | (1) SPECIFY FRAMING CONNECTORS FOR ALL STRUCTURAL | | | FRAMING MEMBERS. SEC. R301.1 FBC-RESIDENTIAL. | | | | | | 4- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.002(33) FOR: | | | ORIGINAL COMMENT: | | | A) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON | | | PLANS. PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL NUMBER | | | AND PAGE SHOWING THE SPECIFIED CONNECTOR OR ENGINEER TO | | | LIST THE FLORIDA PRODUCT APPROVAL NUMBER NEXT TO EACH | | | SPECIFIED CONNECTOR. | | | | | | RESPONSE: | | | REPEAT COMMENT. NOT ADDRESSED. | | | | | | NEW COMMENT: | | | B) GLASS BLOCK AS SHOWN ON REVISED PLANS. | | | | | | 5- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | ABOVE PRODUCT APPROVALS AS REQUIRED BY SEC. 107.3.4.1 | | | CITY AMENDMENTS. | | | | | | NEW COMMENTS: | | | 6- WINDOW DETAILS ON SHEET "B": SPECIFY ALL CONNECTORS | | | OF THE WOOD FRAMING MEMBERS ON THE HEAD DETAIL. SEC. | | | R301.1 FBC-RESIDENTIAL. | | | | | | 7- SHEET "A": | | | A) CLARIFY SECOND NOTE SHOWN ON THE MIDDLE TOP OF SHEET | | | "A". IF EXTERIOR DOORS AE NOT REPLACED, WHY IS THIS | | | NOTE INCLUDED. ALSO, CLARIFY WHY ARE THE DOORS RATED | | | FOR 140 MPH WIND LOAD?. SEE DESIGN STANDARDS ON SAME | | | DRAWING. ALSO, CLARIFY WHAT IS "(AS PER ASD)"?. SEC. | | | 107.2.1 CITY AMENDMENTS. | | | | | | B) CLARIFY STRUCTURAL NOTES BELOW THE "DESIGN | | | STANDARDS". TYPICALLY, SPECIFICATIONS FOR THE | | | ATTACHMENT OF DOORS AND WINDOWS TO THE SUBSTRATE ARE | | | INCLUDED IN THE PRODUCT APPROVALS. WHAT ARE THESE NOTES | | | FOR?. IS THE ENGINEER OF RECORD CHANGING THE PRODUCT | | | APPROVAL SPECIFICATIONS? IF SO, THEN COMPLETE | | | ENGINEERING ANALYSIS IS REQUIRED. SEC. R301.1 | | | FBC-RESIDENTIAL. | | | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-03-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-03-03 |
Time |
18:25 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-03-03 |
Time |
18:13 |
Sent To |
|
|
| Notes |
| 2016-03-03 18:44:30 | RESIDENTIAL (R3) ALTERATIONS BUILDING REVIEW COMMENTS. | | | CODE: FBC-5TH EDITION (2014). | | | | | | 1- THERE ARE TWO STRUCTURES SHOWN ON PLANS SUBMITTED. | | | CONTRACTOR TO SUBMIT A PERMIT APPLICATION FOR EACH | | | STRUCTURE. SEC. 105.1 AND SEC. 107.2.1.4 CITY | | | AMENDMENTS. | | | NOTE: SAME DRAWINGS CAN BE USED FOR BOTH PERMITS, BUT | | | NEED PERMIT APPLICATION FOR EACH STRUCTURE FOR PROPER | | | INSPECTIONS AND RECORD KEEPING. | | | | | | 2- AFTER PLANS ARE APPROVED BY ZONING, BRING THEM TO | | | PALM BEACH COUNTY (2300 N. JOG RD.) FOR IMPACT FEES | | | ASSESSMENT. NOTE: MAKE SURE PALM BEACH COUNTY REVIEWS | | | THE MAIN HOUSE AND THE GARAGE CONVERSION TO LIVABLE | | | SPACE. COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED LAND | | | DEVELOPMENT CODE. | | | | | | 3- PROVIDE ENERGY CALCULATIONS (ONE FOR EACH STRUCTURE) | | | AS REQUIRED BY SEC. R101.4.3 OF FBC-ENERGY | | | CONSERVATION, 5TH EDITION (2014). | | | NOTE: COORDINATE INFORMATION SHOWN ON PLANS AND ENERGY | | | CALCULATIONS TO AVOID CONFLICTS. | | | | | | 4- COMMENTS FOR MAIN HOUSE: | | | A) CLEARLY SPECIFY SCOPE OF WORK. ARE THE EXISTING | | | EXTERIOR DOORS AND WINDOWS GOING TO BE REPLACED. IF SO, | | | THEN SPECIFY THE TYPE AND SIZE OF EXISTING BEDROOM | | | WINDOWS AND SIZE AND TYPE OF PROPOSED BEDROOM WINDOWS | | | TO VERIFY COMPLIANCE WITH THE EGRESS REQUIREMENTS OF | | | SEC. 704 OF FBC-EXISTING BUILDING, 5TH EDITION (2014). | | | | | | B) SPECIFY SAFETY GLAZING FOR WINDOWS LOCATED IN THE | | | NEW FAMILY ROOM, WINDOWS IN THE KITCHEN AREA BY THE | | | EXTERIOR DOOR, BATHROOM WINDOW, WINDOW ADJACENT TO THE | | | ENTRY DOOR AND WINDOW IN BEDROOM #3. (NOTE: IF WINDOWS | | | HAVE IMPACT GLAZING, THEN IT WILL SATISFY THIS CODE | | | REQUIREMENT). | | | | | | C) SPECIFY ALL THE STRUCTURAL CONNECTORS ON THE TYPICAL | | | GABLE WALL FRAMING DETAIL. SEC. R601.2 AND R801.2 OF | | | FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | | | D) PROVIDE GABLE END BRACING DETAIL AS REQUIRED BY SEC. | | | R609.4 AND FIGURE R609.4 OF FBC-RESIDENTIAL, 5TH | | | EDITION (2014). | | | | | | E) REVISE THE STUCCO THICKNESS SPECIFIED ON THE TYPICAL | | | GABLE WALL FRAMING DETAIL. SEE TABLE R702.1(1) OF | | | FBC-RESIDENTIAL, 5TH EDITION (2014) AND REVISE AS | | | REQUIRED. | | | | | | F) SPECIFY ALL THE STRUCTURAL CONNECTORS ON THE TYPICAL | | | WALL DETAIL. SEC. R601.2 AND R801.2 OF FBC-RESIDENTIAL, | | | 5TH EDITION (2014). | | | | | | G) THE CARDINAL ORIENTATION SPECIFIED ON THE EXTERIOR | | | ELEVATIONS AND WALL SECTIONS IS INCORRECT. SEE SURVEY, | | | SITE PLAN OR PALM BEACH COUNTY PROPERTY APPRAISER | | | AERIAL VIEW AND REVISE AS REQUIRED SHOWING THE CORRECT | | | ORIENTATION OF EACH ELEVATION AND WALL SECTION. | | | | | | H) CLARIFY WHY THE NEW FLOOR PLAN CALLS FOR "FAMILY AND | | | BATHROOM ALTERATION" WHILE THE MECHANICAL PLAN CALLS | | | THIS ROOM "MASTER BEDROOM AND MASTER BATH". IT'S | | | IMPORTANT TO DEFINE THE PROPOSED USE OF THIS ROOM TO | | | MAKE THE PROPER BUILDING REVIEW. REVISE AS REQUIRED TO | | | MATCH. SEC. 107.2.1 CITY AMENDMENTS. | | | | | | 5- COMMENTS FOR REAR STRUCTURE: | | | A) SHOW COMPLIANCE WITH THE HEAT REQUIREMENTS OF SEC. | | | R303.9 OF FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | | | B) PROVIDE SURVEY OR SITE PLAN SHOWING ALL SETBACKS | | | FROM THE PROPERTY LINES TO VERIFY COMPLIANCE WITH THE | | | FIRE-RESISTANCE CONSTRUCTION SEC. R02 OF | | | FBC-RESIDENTIAL, 5TH EDITION (2014). | | | | | | C) THE CARDINAL ORIENTATION SPECIFIED ON THE EXTERIOR | | | ELEVATIONS IS INCORRECT. SEE SURVEY, SITE PLAN OR PALM | | | BEACH COUNTY PROPERTY APPRAISER AERIAL VIEW AND REVISE | | | AS REQUIRED SHOWING THE CORRECT ORIENTATION OF EACH | | | ELEVATION. | | | | | | D) THE PROPOSED USE OF THE GARAGE IS NOT CLEAR. SEC. | | | 107.2.1 CITY AMENDMENTS. PROPOSED FLOOR PLAN SHOWS ONE | | | STORAGE ROOM WITH A CLOSET AND AN EXERCISE ROOM. THEY | | | LOOK MORE LIKE BEDROOMS. IF THE INTENTION IS NOT TO USE | | | THEM AS BEDROOMS, THEN CLEARLY IDENTIFY ON PLANS THAT | | | ROOMS ARE NOT TO BE USED FOR SLEEPING PURPOSES. THIS | | | WAY THE BUILDING REVIEW WILL BE APPROVED BASED ON THE | | | PROPOSED USE. | | | | | | E) TYPICAL WALL SECTION: | | | (1) SPECIFY VENTILATION. SEC. R806 OF FBC-RESIDENTIAL, | | | 5TH EDITION (2014). | | | (2) REVISE THE STUCCO THICKNESS SPECIFIED. SEE TABLE | | | R702.1(1) OF FBC-RESIDENTIAL, 5TH EDITION (2014) AND | | | REVISE AS REQUIRED. | | | (3) CLEARLY SHOW THE 6" CLEARANCE REQUIRED BY SEC. | | | R318.7 FOR TERMITE INSPECTION. WALL SECTION SHOWS THAT | | | THE STUCCO IS 2" INTO THE 6" CLEARANCE. REVISE AS | | | REQUIRED. | | | | | | F) ELECTRIC RISER SHOWS "STACKED W/D". NEW FLOOR PLAN | | | DOESN'T SHOW THE LOCATION OF THE WASHER/DRYER. CLARIFY | | | REVISE AS REQUIRED. SEC. 107.2.1 CITY AMENDMENTS. | | | | | | 6- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | | FAC 61G20-3.002(33) FOR: | | | A) ALL EXTERIORS DOORS SHOWN ON PLANS. | | | | | | B) ALL WINDOWS SHOWN ON PLANS. | | | | | | C) HURRICANE SHUTTERS IF DOOR AND WINDOWS DON'T HAVE | | | IMPACT GLAZING. AND PROVIDE COMPLETE INSTALLATION | | | SCHEDULE. | | | | | | D) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON | | | PLANS. PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL NUMBER | | | AND PAGE SHOWING THE SPECIFIED CONNECTOR OR ENGINEER TO | | | LIST THE FLORIDA PRODUCT APPROVAL NUMBER NEXT TO EACH | | | SPECIFIED CONNECTOR. | | | | | | E) WINDOW MULLIONS AS SPECIFIED ON PLANS. AND CLEARLY | | | IDENTIFY MULLION SIZE TO VERIFY COMPLIANCE WITH THE | | | DESIGN PRESSURES OF SEC R301. | | | | | | 7- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | ALL PRODUCT APPROVALS AS REQUIRED BY SEC. 107.3.4.1 | | | CITY AMENDMENTS. | | | | | | 8- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW. VALUATION TO INCLUDE ALL LABOR, MATERIALS, | | | CONTRACTOR'S OVERHEAD AND PROFIT AND ALL DESIGN | | | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY | | | AMENDMENTS. PROVIDE AN UPDATED VALUATION ON EACH PERMIT | | | APPLICATION FOR EACH STRUCTURE. | | | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2017-01-13 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-01-13 |
Time |
08:49 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-01-13 |
Time |
08:49 |
Sent To |
|
|
| Notes |
| 2017-01-12 18:47:57 | NEW PLANS SUBMITTED. NEED RE-STAMP. JG. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2017-01-06 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-01-06 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-01-06 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2016-12-09 10:05:56 | BACK TO SHELF FOR ZONING APPROVAL FIRST |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2016-10-31 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-10-31 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-10-31 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2016-10-31 14:36:09 | 2ND ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA RESIDENTIAL BUILDING CODE 2014 5TH EDITION | | | FLORIDA EXISTING BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 NEC | | | COMMENTS: | | | | | | 1.PLEASE NOTE THAT PREVIOUS COMMENTS HAVE BEEN | | | ADDRESSED. NEW PLANS SHOW TWO NEW METERS FOR PROPOSED | | | WORK. ZONING WILL HAVE TO APPROVE THE SEPERATE METERING | | | TO STUCTURES. ALSO THE SERVICE CONDUCTOR SIZE MUST BE | | | SHOWN, AND REVISED GROUNDING ELECTRODE SIZE BASED ON | | | SERVICE CONDUCTORS SIZE FOR SERVICE. FBC 107.3.5 | | | 2.FURTHER COMMENTS MAY FOLLOW UPON RE-REVIEW. FEEL FREE | | | TO CONTACT ME AT THE NUMBER LISTED BELOW SHOULD YOU | | | HAVE ANY QUESTIONS OR CONCERNS. | | | | | | | | | | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-03-02 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-03-02 |
Time |
05:57 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-03-01 |
Time |
13:21 |
Sent To |
|
|
| Notes |
| 2016-03-02 06:11:55 | INITIAL ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA RESIDENTIAL BUILDING CODE 2014 5TH EDITION | | | FLORIDA EXISTING BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 NEC | | | COMMENTS: | | | | | | 1.PLEASE PROVIDE A PANEL LOAD SCHEDULE REFLECTING ALL | | | LOADS. FBC 107.3.5 | | | 2.ADDRESS RECEPTACLE SPACING IN KITCHEN COUNTERTOP | | | AREA. FBC RES E3901.2.4 | | | 3.ADDRESS RECEPTACLE WALL SPACING IN BEDROOM #2 PER FBC | | | RES E3901.2.2 | | | 4.GFCI PROTECTION REQUIRED FOR ALL RECEPTACLES IN | | | BATHROOM AREA, SEE GUEST BATH. FBC RES E3902.1 | | | 5.PROVIDE NOTES ON PLANS TO REFLECT AFCI AND TAMPER | | | RESISTANT RECEPTACLE REQUIREMENTS. FBC RES E3902.12, | | | FBC RES E4002.14 | | | 6.PROVIDE AND SHOW OUTDOOR RECEPTACLES OUTLETS AT THE | | | FRONT AND BACK OF THE DWELLING PER. FBC RES E3901.7 | | | 7.PROVIDE A HVAC OUTLET PER. FBC RES E3902.12 WITHIN | | | 25FT OF UNIT. | | | 8.FURTHER COMMENTS MAY FOLLOW UPON RE-REVIEW. FEEL FREE | | | TO CONTACT ME AT THE NUMBER LISTED BELOW SHOULD YOU | | | HAVE ANY QUESTIONS OR CONCERNS. | | | | | | | | | | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2017-01-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-01-31 |
Time |
18:36 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-01-12 |
Time |
15:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-01-06 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-01-06 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-01-06 |
Time |
15:32 |
Sent To |
|
|
| Notes |
| 2016-12-01 14:42:58 | R05 - TRAVELLING WITH 16100865 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-11-18 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-11-18 |
Time |
18:12 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-10-27 |
Time |
13:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
F |
Date |
2016-03-11 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2016-03-11 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2016-02-05 |
Time |
08:55 |
Sent To |
|
|
| Notes |
| 2016-03-02 06:12:22 | 3/02 TO BIN R12 | | 2016-02-08 08:56:08 | R12 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
5 |
Status |
N |
Date |
2017-01-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-01-31 |
Time |
18:34 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-01-31 |
Time |
18:07 |
Sent To |
|
|
| Notes |
| 2017-01-31 18:36:08 | NO IMPACT FEES. IMPACT FEES PAID FOR SEPARATE GUEST | | | HOUSE UNDER MU-2017-002418. $180.65. | | 2017-01-31 10:56:31 | 1/30/17 RESUB ROUTED TO JGOMEZ |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
F |
Date |
2017-01-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-01-12 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-01-12 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2017-01-12 15:51:11 | 1- AFTER PLANS ARE APPROVED BY ZONING, BRING THEM TO | | | PALM BEACH COUNTY (2300 N. JOG RD.) FOR IMPACT FEES | | | ASSESSMENT. COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED | | | LAND DEVELOPMENT CODE. | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2016-12-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-12-07 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-12-07 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2016-12-07 15:32:07 | 1- AFTER PLANS ARE APPROVED BY ZONING, BRING THEM TO | | | PALM BEACH COUNTY (2300 N. JOG RD.) FOR IMPACT FEES | | | ASSESSMENT. COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED | | | LAND DEVELOPMENT CODE. | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2016-11-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-11-17 |
Time |
16:45 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-11-17 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2016-11-17 16:46:57 | 1- AFTER PLANS ARE APPROVED BY ZONING, BRING THEM TO | | | PALM BEACH COUNTY (2300 N. JOG RD.) FOR IMPACT FEES | | | ASSESSMENT. COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED | | | LAND DEVELOPMENT CODE. | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2016-03-03 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-03-03 |
Time |
18:44 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-03-03 |
Time |
18:44 |
Sent To |
|
|
| Notes |
| 2016-03-03 18:45:12 | 1- AFTER PLANS ARE APPROVED BY ZONING, BRING THEM TO | | | PALM BEACH COUNTY (2300 N. JOG RD.) FOR IMPACT FEES | | | ASSESSMENT. COUNTY IMPACT FEE ORDINANCE OF THE UNIFIED | | | LAND DEVELOPMENT CODE. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2017-01-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-01-12 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-01-12 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2017-01-12 15:45:49 | MECHANICAL REVIEW APPROVED WITH PROVISO: | | | 1- BALANCED AIR TEST REQUIRED. SEE A/C PLANS SUBMITTED. | | | 2- EQUIPMENT SIZING CALCULATIONS WERE REVISED AND ONLY | | | THE PROJECT SUMMARY SHEET WAS SUBMITTED. PROVIDE | | | COMPLETE LOAD CALCULATIONS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2016-12-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-12-07 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-12-07 |
Time |
15:32 |
Sent To |
|
|
| Notes |
| 2016-12-07 15:33:18 | MECHANICAL REVIEW APPROVED WITH PROVISO: | | | | | | 1- BALANCED AIR TEST REQUIRED. SEE A/C PLANS SUBMITTED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2016-11-18 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-11-18 |
Time |
17:28 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-11-18 |
Time |
17:28 |
Sent To |
|
|
| Notes |
| 2016-11-18 18:12:44 | RESIDENTIAL (R3) ALTERATIONS SECOND MECHANICAL REVIEW | | | CHECKLIST. | | | CODE: FBC-5TH EDITION (2014). | | | | | | 1- PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS. | | | INFORMATION SUBMITTED IS ONLY THE SUMMARY. NEED TO | | | PROVIDE THE COMPLETE CALCULATIONS SHOWING THE ACTUAL | | | BUILDING ORIENTATION AND COMPLETE EQUIPMENT INFORMATION | | | AS REQUIRED BY SEC. R403.6.1 FBC-ENERGY CONSERVATION, | | | 5TH EDITION (2014). | | | | | | 2- A/C PLAN SUBMITTED: | | | A) EQUIPMENT SHOWN ON PLANS DON'T MATCH EQUIPMENT | | | LISTED ON THE NEW SUMMARY SUBMITTED. REVISE AS | | | REQUIRED. SEC. 107.2.1 CITY AMENDMENTS. | | | | | | B) A/C PLAN DON'T SHOW COMPLIANCE WITH THE BALANCED | | | RETURN AIR AS REQUIRED BY SEC. M1602.4 OF | | | FBC-RESIDENTIAL, 5TH EDITION (2014). TYPICALLY, | | | TRANSFER DUCTS OR TRANSFER GRILLES ARE INSTALLED FOR | | | BALANCED RETURN AIR. AND, THE DOOR HAS AT LEAST AN | | | UNRESTRICTED 1 INCH UNDERCUT TO ACHIEVE PROPER RETURN | | | AIR BALANCE. SEE EXCEPTIONS ON SEC. M1602.4 | | | FBC-RESIDENTIAL. NOTE: THERE IS A NOTE STATING "RETURN | | | AIR BALANCE WILL BE PROVIDED BY UNDERCUTTING ALL DOORS | | | A MIN. OF 1-1/2" OFF THE FINISHED FLOOR". THIS MAY NOT | | | BE ENOUGH TO ACCOMPLISH TO BALANCED RETURN AIR. A | | | BALANCED RETURN TEST NEED TO BE PERFORMED TO VERIFY | | | COMPLIANCE. ENGINEER OF RECORD TO SPECIFY ON PLANS THAT | | | BALANCE TEST IS REQUIRED OR SHOW COMPLIANCE WITH THE | | | EXCEPTIONS OF SEC. M1602.4. | | | | | | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-03-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-03-04 |
Time |
18:09 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-03-04 |
Time |
16:57 |
Sent To |
Z |
|
| Notes |
| 2016-03-04 18:34:18 | RESIDENTIAL (R3) ALTERATIONS MECHANICAL REVIEW | | | COMMENTS. | | | CODE: FBC-5TH EDITION (2014). | | | | | | 1- THERE ARE TWO STRUCTURES SHOWN ON PLANS SUBMITTED. | | | CONTRACTOR SUBMITTED ONLY MECHANICAL INFORMATION FOR | | | THE MAIN HOUSE. IF MECHANICAL WORK IS PROPOSED FOR THE | | | GARAGE CONVERSION, THEN PROVIDE COMPLETE INFORMATION | | | UNDER SEPARATE PERMIT APPLICATION. SEC. 105.1 AND SEC. | | | 107.2.1.4 CITY AMENDMENTS. | | | | | | 2- REVISE THE EQUIPMENT SIZING CALCULATIONS SUBMITTED: | | | A) COORDINATE EQUIPMENT SIZING CALCULATIONS WITH THE | | | INFORMATION ON THE ENERGY CALCULATIONS REQUIRED BY ITEM | | | #3 OF BUILDING REVIEW COMMENTS. SEC. R103.2 OF | | | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | | | | | B) HOME ADDRESS IS INCORRECT. SEC. 107.2.1 CITY | | | AMENDMENTS. | | | | | | C) NUMBER OF BEDROOMS IS INCORRECT. SEC. R103.2 OF | | | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | | | | | D) SQUARE FOOTAGE DOESN'T MATCH SQUARE FOOTAGE SHOWN ON | | | ENGINEER'S PLANS. SEC. R103.2 OF FBC-ENERGY | | | CONSERVATION, 5TH EDITION (2014). | | | | | | E) CLARIFY WHY THE NUMBER OF OCCUPANTS IS 9. HOW MANY | | | OCCUPANTS ARE CONSIDERED PER BEDROOM?. NUMBER OF | | | OCCUPANTS DOESN'T MATCH NUMBER SHOWN ON THE REPORT | | | INVESTMENT #2 AND #3. .SEC. R103.2 OF FBC-ENERGY | | | CONSERVATION, 5TH EDITION (2014). | | | | | | F) WINDOWS INFORMATION IS INCORRECT. SEC. R103.2 OF | | | FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | | | | | G) ENGINEER PLANS DON'T SHOW ANY GAS WATER HEATER. SEC. | | | R103.2 OF FBC-ENERGY CONSERVATION, 5TH EDITION (2014). | | | | | | H) PROJECT SUMMARY IS MISSING THE SELECTED EQUIPMENT | | | SENSIBLE COOLING, LATENT COOLING AND TOTAL COOLING | | | CAPACITY. SEC. R403.6.1 OF FBC-ENERGY CONSERVATION, 5TH | | | EDITION (2014). | | | | | | 3- A/C PLAN SUBMITTED: | | | A) THERE IS A DISCREPANCY WITH THE ENGINEER PLANS AND | | | THE A/C PLAN. COORDINATE WITH THE ENGINEER OF RECORD | | | AND CLARIFY WHY THE NEW FLOOR PLAN CALLS FOR "FAMILY | | | AND BATHROOM ALTERATION" WHILE THE MECHANICAL PLAN | | | CALLS THIS ROOM "MASTER BEDROOM AND MASTER BATH". IT'S | | | IMPORTANT TO DEFINE THE PROPOSED USE OF THIS ROOM TO | | | MAKE THE PROPER BUILDING REVIEW. REVISE AS REQUIRED TO | | | MATCH. SEC. 107.2.1 CITY AMENDMENTS. | | | NOTE: THIS WILL ALSO AFFECT THE INFORMATION ON THE | | | EQUIPMENT SIZING CALCULATIONS AND A/C PLAN. COORDINATE | | | AS REQUIRED TO AVOID CONFLICTS. | | | | | | 4- MASTER BEDROOM TRANSFER GRILL SIZE DOESN'T COMPLY | | | WITH THE BALANCED RETURN AIR SEC. M1602.4 OF | | | FBC-RESIDENTIAL, 5TH EDITION (2014). NOTE: KEEP IN MIND | | | THAT THE SIZE OF THE GRILL IS BASED ON ALL THE SUPPLY | | | AIR TO THE MASTER BEDROOM AND MASTER BATHROOM. | | | | | | 5- ADDITIONAL BEDROOMS: PROVIDE COMPLIANCE WITH THE | | | BALANCED RETURN AIR SEC. M1602.4 OF FBC-RESIDENTIAL, | | | 5TH EDITION (2014). | | | | | | 6- PROVIDE THE NAME AND SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR THE DESIGN AS REQUIRED BY SEC. 107.2.1 | | | CITY AMENDMENTS. | | | | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2017-01-20 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-01-20 |
Time |
10:14 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-01-20 |
Time |
10:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2016-12-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-12-22 |
Time |
16:32 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-12-22 |
Time |
13:52 |
Sent To |
|
|
| Notes |
| 2016-12-22 16:29:39 | 2ND REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. WATER HEATER SHALL COMPLY WITH FBC RES M1305.1.3 | | | APPLIANCES IN ATTICS. | | | ATTICS CONTAINING APPLIANCES SHALL BE PROVIDED WITH AN | | | OPENING AND A CLEAR AND UNOBSTRUCTED PASSAGEWAY LARGE | | | ENOUGH TO ALLOW REMOVAL OF THE LARGEST APPLIANCE, BUT | | | NOT LESS THAN 30 INCHES (762 MM) HIGH AND 22 INCHES | | | (559 MM) WIDE AND NOT MORE THAN 20 FEET (6096 MM) LONG | | | MEASURED ALONG THE CENTERLINE OF THE PASSAGEWAY FROM | | | THE OPENING TO THE APPLIANCE. THE PASSAGEWAY SHALL HAVE | | | CONTINUOUS SOLID FLOORING IN ACCORDANCE WITH CHAPTER 5 | | | NOT LESS THAN 24 INCHES (610 MM) WIDE. A LEVEL SERVICE | | | SPACE AT LEAST 30 INCHES (762 MM) DEEP AND 30 INCHES | | | (762 MM) WIDE SHALL BE PRESENT ALONG ALL SIDES OF THE | | | APPLIANCE WHERE ACCESS IS REQUIRED. THE CLEAR ACCESS | | | OPENING DIMENSIONS SHALL BE A MINIMUM OF 20 INCHES BY | | | 30 INCHES (508 MM BY 762 MM), AND LARGE ENOUGH TO ALLOW | | | REMOVAL OF THE LARGEST APPLIANCE. P2801 WATER HEATERS | | | | | | 2. WASHING MACHINE STACK SHALL CONNECT TO THE BUILDING | | | DRAIN DOWN STEAM OF BATHROOM GROUP. PER FBC RES P3108.1 | | | | | | 3. COMPLY WITH BUILDING COMMENTS. PER WPB AMEND TO FBC | | | 107.2.1 | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2016-11-18 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-11-07 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-11-07 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2016-11-18 15:42:31 | 2ND REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE WATER HEATER SHALL NOT BE INSTALLED IN CORNER OF | | | THE KITCHEN CABINETS PROPER ACCESS CAN NOT BE PROVIDED. | | | PER FBC PL | | | P2801.3 LOCATION. | | | WATER HEATERS AND STORAGE TANKS SHALL BE INSTALLED IN | | | ACCORDANCE WITH SECTION M1305 AND SHALL BE LOCATED AND | | | CONNECTED TO PROVIDE ACCESS FOR OBSERVATION, | | | MAINTENANCE, SERVICING AND REPLACEMENT. | | | M1305.1 APPLIANCE ACCESS FOR INSPECTION SERVICE, REPAIR | | | AND REPLACEMENT. | | | APPLIANCES SHALL BE ACCESSIBLE FOR INSPECTION, SERVICE, | | | REPAIR AND REPLACEMENT WITHOUT REMOVING PERMANENT | | | CONSTRUCTION, OTHER APPLIANCES, OR ANY OTHER PIPING OR | | | DUCTS NOT CONNECTED TO THE APPLIANCE BEING INSPECTED, | | | SERVICED, REPAIRED OR REPLACED. A LEVEL WORKING SPACE | | | AT LEAST 30 INCHES DEEP AND 30 INCHES WIDE (762 MM BY | | | 762 MM) SHALL BE PROVIDED IN FRONT OF THE CONTROL SIDE | | | TO SERVICE AN APPLIANCE. INSTALLATION OF ROOM HEATERS | | | SHALL BE PERMITTED WITH AT LEAST AN 18-INCH (457 MM) | | | WORKING SPACE. A PLATFORM SHALL NOT BE REQUIRED FOR | | | ROOM HEATERS. | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-02-18 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-02-18 |
Time |
13:27 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-02-18 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2016-02-18 13:38:44 | 1ST REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | | | | 1.ON MAIN HOUSE THE DRAIN FOR WASHING MACHINE SHALL TIE | | | INTO BUILDING DRAIN DOWNSTREAM OF BATHROOM GROUP. | | | PER FBC PL. SEC. 912.1 | | | 2. IN GUEST HOUSE KITCHEN DRAIN SHALL TIE INTO BUILDING | | | DRAIN DOWN STEAM OF BATHROOM GROUP. | | | PER FBC PL. SEC. 912.1 | | | 3. PROVIDE MANUFACTURE SPECS FOR ANY NEW WATER HEATERS. | | | PER WPB AMEND. TO FBC SEC.107.2.1.3 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-01-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2017-01-12 |
Time |
11:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2016-12-19 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2016-12-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2016-12-19 |
Time |
11:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2016-11-02 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2016-11-02 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2016-11-02 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2016-11-02 15:13:13 | 11/2/16- FAILED- THE REAR STRUCTURE CAN NOT HAVE A | | | SEPERATE METER. | | | ANGELLA VANN | | | [email protected] | | | 561-822-1441 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2016-03-11 |
|
|
Cont ID |
|
| Sent By |
ajones |
Date |
2016-03-11 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
ajones |
Date |
2016-03-11 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2016-03-11 11:08:54 | 3/11/16- FAILED- NEED A SURVEY OF THE PROPERTY | | | INIDICATING THE AREAS BEING AFFECTED. | | | ANGELLA VANN, AICP | | | 561-822-1441 | | | [email protected] |
|
|