Plan Review Details - Permit 16020194
Plan Review Stops For Permit 16020194
Review Stop AD ADDRESSING
Rev No 3 Status P Date 2016-09-09 Cont ID  
Sent By shill Date 2016-09-09 Time 09:26 Rev Time 0.00
Received By shill Date 2016-09-09 Time 09:26 Sent To  
Notes
2016-09-09 09:31:44OLD ADDRESS IN COMMUNITY PLUS FOR VIBROFLOTATION PERMIT
 WAS 410 DATURA
 NEW PRIMARY ADDRESS IS 499 EVERNIA STREET, PENDING
 REPLAT AND NEW PARCEL ID
 OTHER ADDRESSES ASSIGNED, WILL BE ENTERED INTO
 COMMUNITY PLUS AFTER
 UNIT NUMBERS PROVIDED BY OWNER (MR. ANDERSON) AND
 APPROVED, PENDING REPLAT AND PARCEL ID
  
 PER MIKE ORIO, [email protected]
 561-494-1080
  

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2016-07-01 Cont ID  
Sent By shill Date 2016-07-01 Time 13:38 Rev Time 0.00
Received By shill Date 2016-07-01 Time 13:38 Sent To  
Notes
2016-07-01 13:39:43IN ADDRESSING WITH MIKE ORIO
 FINAL ADDRESSES WILL BE ASSIGNED PRIOR TO PERMIT
 ISSUANCE (OR PRIOR TO C.O.)
  

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2016-03-18 Cont ID  
Sent By shill Date 2016-03-18 Time 08:11 Rev Time 0.00
Received By shill Date 2016-03-18 Time 08:11 Sent To  
Notes
2016-03-18 08:36:05****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. THIS PROJECT HAS BEEN FORWARDED TO OUR ADDRESSING
 DEPARTMENT. ADDRESSING WILL BE COMPLETE PRIOR TO PERMIT
 ISSUANCE. ADDITIONAL INFORMATION FROM DESIGNER OR OWNER
 MAY BE REQUIRED.
  
  
  
  
  
2016-03-16 14:11:22ADDRESSING WILL BE PRIOR TO ISSUANCE, NOT A PART OF THE
 FIRST REVIEW.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2016-10-21 Cont ID  
Sent By shill Date 2016-10-21 Time 13:58 Rev Time 0.00
Received By shill Date 2016-10-21 Time 13:58 Sent To  
Notes
2016-10-21 14:01:26****PROVISO****
 ****ISSUED AT CONTRACTOR'S RISK****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. AS THE POOL COURTYARD OCCUPANT LOAD IS NOW OVER 500
 (WAS 395 IN PREVIOUS REVIEW), THREE MEANS OF EGRESS ARE
 REQUIRED, FBC 1004.5, 1021.2.4.
  
 ALSO SEE FBC 1005.5 REGARDING LOSS OF AN EXIT.
  
 THE RESPONSE LETTER AND EGRESS CAPACITY TABULATIONS
 CALCULATE GATE 161 AS A DOUBLE 4 FT, BUT THE PLANS
 (A2.1, LS 0.1, OTHER SHEETS) DEPICT A SINGLE GATE.
  
 A SINGLE GATE IS SHOWN ADJACENT TO THE DOUBLE GATE 160.
 AS THIS MEANS OF EGRESS IS REQUIRED, REVISE THE EGRESS
 CAPACITY CALCULATIONS TO INCLUDE THIS GATE.
  
 PER ARCHITECT, THE POOL COURTYARD OCCUPANT LOAD WAS
 OVERSTATED DUE TO AREAS OF LARGE PLANTERS /
 LANDSCAPING. A REVISION SHOWING AN OCCUPANT LOAD UNDER
 500 OR THREE MEANS OF EGRESS IS REQUIRED.
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2016-09-09 Cont ID  
Sent By shill Date 2016-09-09 Time 15:42 Rev Time 0.00
Received By shill Date 2016-09-09 Time 08:29 Sent To  
Notes
2016-09-09 15:42:27****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. AS THE POOL COURTYARD OCCUPANT LOAD IS NOW OVER 500
 (WAS 395 IN PREVIOUS REVIEW), THREE MEANS OF EGRESS ARE
 REQUIRED, FBC 1004.5, 1021.2.4.
  
 ALSO SEE FBC 1005.5 REGARDING LOSS OF AN EXIT.
  
 THE RESPONSE LETTER AND EGRESS CAPACITY TABULATIONS
 CALCULATE GATE 161 AS A DOUBLE 4 FT, BUT THE PLANS
 (A2.1, LS 0.1, OTHER SHEETS) DEPICT A SINGLE GATE.
  
 A SINGLE GATE IS SHOWN ADJACENT TO THE DOUBLE GATE 160.
 AS THIS MEANS OF EGRESS IS REQUIRED, REVISE THE EGRESS
 CAPACITY CALCULATIONS TO INCLUDE THIS GATE.
  
 2. THIS REVIEW CAN BE PASSED WITH PROVISO THAT AFFECTED
 SHEETS ARE REVISED PRIOR TO BUILDING DRY IN. ARCHITECT
 IS TO REQUEST PROVISO VIA EMAIL WITH AN EXPLANATION OF
 POOL DECK MEANS OF EGRESS FUTURE REVISION.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-07-01 Cont ID  
Sent By shill Date 2016-07-01 Time 13:36 Rev Time 0.00
Received By shill Date 2016-07-01 Time 13:36 Sent To  
Notes
2016-07-01 13:37:02****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 GOVERNING CODE: FBC 5TH EDITION (FBC 2014)
  
 1-6. OK; ALSO SEE THRESHOLD AND IMPACT FEE REVIEWS.
  
 7. TWO DOCUMENTS WERE UPLOADED AS LAND AND TITLE SURVEY
 (003-01 AND 004-02) BUT BOTH DOCUMENTS ARE ONE PAGE,
 FIRST PAGE OF A TWO PAGE SURVEY. PROVIDE THE SECOND
 PAGE, FBC 107.
  
 8-10. OK
  
 11. LS0.1, A SURFACE MOUNT FIRE EXTINGUISHER IS
 DEPICTED ON THE RAMP (S2 TO BUSINESS/RESIDENTIAL) BUT
 DOES NOT APPEAR ON SHEET A2.1; THIS DOES NOT APPEAR TO
 COMPLY WITH FBC 1003.3, 1012.8, FBC 5TH ED.
 ACCESSIBILITY 405.5.
  
 2ND REVIEW, RESPONSE STATES THAT THIS WAS RELOCATED BUT
 A SFE IS NOW SHOWN ON THE LANDING OF THE RAMP ON LS0.1,
 BUT IS NOT ON SHEET A2.1 (AND RESPONSE LETTER APPEARS
 TO IMPLY THAT INTENT WAS TO REMOVE IT FROM THE RAMP);
 SAME COMMENTS APPLY. EITHER REMOVE OR CORRELATE WITH
 A2.1 AND PROVIDE DIMENSIONS TO CLARIFY COMPLIANCE.
  
 12-16. OK
  
 17. LS 0.1, IT APPEARS THAT INTERMEDIATE HANDRAILS ARE
 REQUIRED AT THE STAIR AT DOOR 115, FBC 1012.9. REVISE
 THIS SHEET AND PROVIDE A DIMENSIONED DETAIL FOR THE
 STAIR, FBC 107.
  
 RESPONSE LETTER STATES THAT THIS WAS ADDED, BUT LS0.1
 AND A2.1 DO NOT APPEAR TO BE REVISED AT THIS LOCATION,
 PLEASE CORRELATE.
  
 18-20. OK
  
 21. LS 0.1, REVISE PLAN TO CLARIFY THE NUMBER OF
 OCCUPANTS EXITING THROUGH GATE 160. EXIT STAIR 4, EXIT
 STAIR 6, POOL AREA, CLUBHOUSE, 1ST FLOOR RESIDENTIAL
 LEAD TO THIS EXIT.
  
 2ND REVIEW, OCCUPANCY CALCS AND RESPONSE LETTER SHOW AN
 OCCUPANT LOAD OF 395. PLEASE REVISE; PLAN SHOWS AT
 LEAST 468 (POOL DECK 375, POOL 50, GRILL AREA 20, A3
 COVERED 23) OR CLARIFY. ALSO INCLUDE THE AREA WHICH IS
 NOT DESIGNATED ON THE LIFE SAFETY PLAN BUT IS SHOWN ON
 A2.1 AS OUTDOOR LIVING.
 LS0.1 EGRESS CAPACITY TABULATIONS INDICATE THAT THERE
 IS A 38IN EXIT IN ADDITION TO TWO 68IN EXITS. I WAS
 UNABLE TO LOCATE THE 38IN EXIT FOR THIS AREA, PLEASE
 CLARIFY OR REVISE. NOTE THAT EXITING APPEARS COMPLIANT
 WITHOUT THE THIRD EXIT.
  
 22-25. OK
  
 26. LS 0.2 AND OTHER SHEETS, A SURFACE MOUNT FIRE
 EXTINGUISHER IS SHOWN WHERE IT APPEARS TO OBSTRUCT THE
 ACCESSIBLE PARKING ACCESS AISLE. PROVIDE DIMENSIONS TO
 SHOW THAT THE ACCESS AISLE IS NOT OBSTRUCTED.
  
 2ND REVIEW, RESPONSE LETTER STATES THIS WAS MOVED BUT
 THIS STILL APPEARS ON LS0.2, PLEASE CHECK ALL FLOORS
 AND REVISE.
  
 27. LS 0.2, LS 0.4, UNITS A1 AND C2, TENANT / OCCUPANCY
 SEPARATION BETWEEN THE R2 UNITS AND THE A2 CORRIDOR IS
 LACKING, FBC TABLE 508.4.
  
 2ND REVIEW, RESPONSE LETTER STATES THIS WAS PROVIDED
 BUT PLAN WAS NOT REVISED. PLEASE SEE WALL BETWEEN S2
 AND R2 ADJACENT TO STAIR 2.
  
 28. LS 0.4, THE DOORS SERVING THE NORTH ROOF DECK ARE
 TO SWING IN THE DIRECTION OF EGRESS TRAVEL, FBC
 1008.1.10.
  
 2ND REVIEW, PLEASE ALSO CLARIFY COMPLIANCE WITH FBC
 1015.2.1. 11FT IS SHOWN BETWEEN THE TWO EXITS, BUT IT
 APPEARS THAT THE DIAGONAL IS GREATER THAN 33.
  
 29-30. OK
  
 31. SHEET S1 2A, SPECIFY FLOOR LOADS FOR THE ASSEMBLY
 AREAS (CLUBHOUSE ROOF DECK, GYM, EXERCISE ROOM).
  
 2ND REVIEW, RESPONSE LETTER REFERS TO LS SHEETS BUT I
 WAS UNABLE TO LOCATE THIS REVISION. PLEASE ALSO
 INCORPORATE INTO THE APPLICABLE STRUCTURAL SHEET.
  
 33-36. OK
  
 36. S6.0, WALL PRESSURES SPECIFIED AND SOME PRODUCT
 APPROVALS WERE SUBMITTED BUT THE CHART IS A GENERAL
 ONE, NOT SPECIFIC TO EACH OPENING. THE PRODUCT
 APPROVALS ARE NOT MARKED TO INDICATE WHICH OF THE
 OPTIONS IS PROPOSED. EITHER PROVIDE A SCHEDULE TO SHOW
 DESIGN PRESSURES FOR EACH OPENING AND PRODUCT APPROVALS
 MARKED TO SHOW WHICH OPTION PROPOSED FOR EACH OPENING
 (OR ONE TO BE USED FOR ALL OPENINGS TO COMPLY WITH
 WORST CASE), OR THIS WILL BE A PROVISO ITEM (PROVIDE
 FOR REVIEW PRIOR TO INSTALLATION).
  
 2ND REVIEW, RESPONSE LETTER DIRECTED ME TO THE PAGE
 WHERE FOUR PRODUCTS ARE REFERENCED. THE FOLLOWING
 ISSUES ARE NOTED:
  
 THE FIXED WINDOW PRODUCT APPROVAL REFERENCED ON SHEET
 A4.7 IS FOR SMALL MISSILE IMPACT; LMI REQUIRED BELOW
 30FT (LMI NOA NOT INCLUDED IN THE PRODUCTS REVIEWED,
 BUT NOA UPLOADED, PLEASE CORRELATE).
  
 THE SERIES 9500 LMI FIXED WINDOW WAS UPLOADED, BUT IS
 NOT INCLUDED IN THE PRODUCTS REVIEWED (SHEET A4.7).
  
 THE FRENCH DOOR NOA 150611.10 PROVIDED DOES NOT APPEAR
 TO INCLUDE PANIC BAR HARDWARE OPTION, SO THIS PRODUCT
 CANNOT BE USED IN THE MEANS OF EGRESS FOR ASSEMBLY
 OCCUPANCY. THIS HAS BEEN INCLUDED IN THE PROVISO LIST
 (SUBMIT PRIOR TO INSTALLATION).
  
 ALL PRODUCT APPROVALS WERE REVIEWED FOR COMPLIANCE WITH
 WORST CASE DESIGN PRESSURES. MOST OPTIONS COMPLY.
 PROVISO; COMPONENT AND CLADDING TO COMPLY WITH WORST
 CASE DESIGN PRESSURES OR SUBMIT A SCHEDULE OF
 APPLICABLE OPENINGS AND PROPOSED INSTALLATION.
  
 37. 2ND REVIEW, THE SOFFIT DETAIL LACKS A BOND BREAK
 REQUIRED (TWO LAYERS VAPOR BARRIER); PLEASE REVISE
 DETAIL ACCORDINGLY, FBC 1403.2, ASTM C926.
  
 38-40. OK
  
 41. SEE PLUMBING COMMENTS REGARDING FAIR HOUSING. ALL
 COMMENTS ARE ALSO APPLICABLE FOR BUILDING REVIEW.
  
 42. REGARDING ENERGY CALCS, IT APPEARS THAT THERE IS A
 47,771 SF DISCREPANCY BETWEEN THE AREA ON THE ENERGY
 CALCS (CONDITIONED AREA 312,869) AND THE A SHEETS.
 NUMBER OF STORIES ON EC IS 5, NOT CONSISTENT WITH PLAN.
 THE DIGITAL SIGNATURE IS FOR VIVIANA FRANYIE, BUT THE
 PRINTED SEAL IS FOR ALEJANDRO FRANYIE (THIS APPLIES TO
 SOME OF THE FMEP SHEETS AS WELL, PLEASE CORRECT,
 FS471).
  
 43-46. OK
  
 47. SIGNED & SEALED SOILS REPORT WAS NOT UPLOADED BUT
 AN ORIGINAL WAS SUBMITTED WITH THE (ISSUED)
 VIBROFLOTATION PERMIT, SO NOT REQUIRED FOR THIS PERMIT.
  
 THE STRUCTURAL CALCS ARE NOT DIGITALLY SIGNED AND
 SEALED; PLEASE ADDRESS.
  
 48-49. OK
  
 49. PROVISO;
  
 50. ADVISORY ONLY; SOME (BUT NOT ALL) PRODUCT APPROVALS
 HAVE BEEN SUBMITTED. APPLICANT MAY ELECT TO DEFER
 PRODUCT APPROVAL SUBMITTAL. THEY CAN BE SUBMITTED AFTER
 PERMIT ISSUANCE, PRIOR TO INSTALLATION, WITH NO
 ADDITIONAL FEES.
  
 51. SEE ROOF REVIEW COMMENTS:
  
 ROOF NOAS FOR JM TPO SUBMITTED; 14-0618.03, 13-0529.02
  
 A. ROOF PRODUCT APPROVALS WERE SUBMITTED BUT THE
 ASSEMBLY PROPOSED WAS NOT SELECTED AND ENGINEERING FOR
 ENHANCED FASTENING (WOOD DECK) WAS NOT PROVIDED. IF
 THIS INFORMATION IS NOT PROVIDED PRIOR TO PERMIT
 ISSUANCE, THE INFORMATION WILL BE REQUIRED AT TIME OF
 ROOF SUB PERMIT SUBMITTAL. AN "N" WILL BE ENTERED FOR
 THE ROOF PLAN REVIEW.
  
 ROOF ASSEMBLIES SELECTED TO COMPLY WITH THE (VULT)
 PRESSURES SPECIFIED ON SHEET S6-1.
  
 B. SHEET S6-1, CLARIFY THE DIFFERENCE BETWEEN THE "ROOF
 MEMBRANE DESIGN PRESSSURE" VS. "GROSS UPLIFT DESIGN
 PRESSURES." THE DESIGN PRESSURES TO BE UTILIZED FOR THE
 TPO ROOF IS NOT CLEAR.
  
 C. SHEET S6-1, IT APPEARS THAT ROOF PRESSURES SPECIFIED
 USE ZONE 2 PRESSURES FOR ZONE 3. THE STAIR ROOFS,
 ELEVATOR ROOFS, CANOPIES (DETAIL 1-S4.1, A SHEETS
 BUILDING SECTIONS, OTHER PLACES) DO NOT INCLUDE A 3FT
 PARAPET, FBC 1609, ASCE7 10 30.6-1 NOTE 7. SEE ALSO
 ROOF REVIEW COMMENTS. IT IS NOT CLEAR WHICH DESIGN
 PRESSURES ARE SPECIFIED FOR THE ROOF.
  
 D. PLAN SHEET S1.9C AND OTHER SHEETS INCLUDE AN
 INDICATOR FOR DETAIL 1 S9.1A; UNABLE TO LOCATE THIS
 SHEET (S9.1A). PLEASE PROVIDE SHEET OR REVISE DETAIL
 INDICATOR TO CORRECT LOCATION.
  
 54-56. OK
  
 RESPONSE LETTER STOPS AT COMMENT #56. AS IT IS NOT
 CLEAR WHICH OF THE ITEMS HAVE BEEN REVISED, OR WHERE,
 COMMENTS REMAIN.
  
 58. A2.1, THE DOOR FOR UNIT 140 AND OTHER UNITS ARE NOT
 LABELED, FBC 107. THE INDEX SHOWS A DOOR SCHEDULE FOR
 THE AMENITY AREA. PLEASE ADVISE AS TO WHERE THE UNIT
 ENTRY DOOR SCHEDULE IS LOCATED OR PROVIDE.
  
 59. FBC 424.1.3.1.9, 424.2.17, POOL BARRIER PROPOSED IS
 NOT CLEAR (WINDOWS LOCATED IN THE WALL WHICH SERVES AS
 THE POOL BARRIER).
  
 2ND REVIEW; A NOTE WAS ADDED TO STATE THAT ALL UNIT
 BALCONY RAILINGS ARE AT 48IN (LS0.1). PLEASE REVISE
 PLAN TO SHOW INTENT FOR POOL BARRIER FOR THE FIRST
 FLOOR WINDOWS WHICH DIRECTLY FACE THE POOL.
  
 60. SHEET A6.1, ITEM 68 SPECIFIES RIGID INSULATION, NOA
 11-0516.02; THIS IS THE NOA NUMBER FOR WATERPROOFING,
 REVISE; ALSO SEE OTHER COMMENTS REGARDING NOA NUMBERS
 ON THE PLAN.
  
 61. PROVIDE A GRAB BAR BACKING DETAIL, FBC 107.
  
 62. FHA, NOT ALL OF THE SLIDING GLASS DOORS PROPOSED
 ARE 6FT; FOR INSTANCE, SEE UNIT S2, SHEET A4.1. SEE
 PAGE 3.10 OF THE FAIR HOUSING ACT DESIGN MANUAL AND THE
 GUIDANCE REGARDING SLIDING GLASS PATIO DOORS (SECONDARY
 DOOR) AND REVISE PLAN TO DEMONSTRATE COMPLIANCE.
  
 63. DETAIL 2-S4.1 GRAPHICALLY DEPICTS AN EMBEDDED STRAP
 BUT DOES NOT SPECIFY. PLEASE EITHER PROVIDE INFORMATION
 AS TO WHERE THIS INFORMATION CAN BE FOUND OR REVISE
 PLAN TO SPECIFY CONNECTORS.
  
 64. DETAILS 1 AND 2, S4.1, PLEASE PROVIDE DIRECTION AS
 TO WHICH PLAN VIEW SHEET THE DETAIL INDICATOR FOR THESE
 DETAILS ARE LOCATED.
  
 65. FIRST FLOOR (LS 0.1 AND OTHER SHEETS), ADJACENT TO
 STAIR 3, A RAMP IS SHOWN BUT NO STAIR TO ACCESS THE
 RESIDENTIAL CORRIDOR FROM THE GARAGE. IT IS SUGGESTED
 THAT AN ACCESSIBLE STAIR BE ADDED. THE RAMP ADDS
 DISTANCE TO THE PATH OF TRAVEL WHICH COULD BE A
 HARDSHIP FOR SOMEONE WHO IS DISABLED OR COMPROMISED,
 DOES NOT USE A WHEELCHAIR AND IS ABLE TO NAVIGATE A
 STAIR.
  
 66. OK
  
 NEW COMMENT:
  
 67. WHEN RESUBMITTING, PLEASE PROVIDE AN UPDATED INDEX
 SPREADSHEET TO INDICATE WHICH SHEETS CHANGED IN THIS
 AND NEXT REVIEWS. ALL SHEETS HAVE NOT BEEN REVIEWED AT
 THIS TIME AS ALL SHEETS WERE REPLACED DUE TO DIGITAL
 SIGNATURE, ONLY SHEETS WHICH WERE AFFECTED BY THIS
 COMMENT LIST. IF PROVIDED WITH A LIST OF ALL SHEETS
 WITH CHANGES FOR THIS SUBMITTAL, THIS WILL EXPEDITE THE
 LAST REVIEW AS ALL SHEETS WILL BE CHECKED PRIOR TO
 ISSUANCE.
  
 THIS LIST MAY BE SENT TO ME VIA EMAIL PRIOR TO
 RESUBMITTAL AND THE SHEETS WILL BE REVIEWED IN THIS
 CYCLE.
  
 THIS PERMIT WILL BE ISSUED WITH THE FOLLOWING PROVISOS:
  
 1. PER FS 553.79, ALL SHORING/RE-SHORE ENGINEERING IS
 TO BE REVIEWED BY ENGINEER OF RECORD AND THREE SIGNED
 AND SEALED ORIGINAL SETS ARE TO BE SUBMITTED FOR PLAN
 REVIEW. THE SHORING/RESHORE ENGINEERING IS TO BE
 REVIEWED AND APPROVED PRIOR TO INSPECTION. THE CITY
 APPROVED (CITY STAMPED) SHORING/RE-SHORE ENGINEERING IS
 TO BE AVAILABLE ON THE JOB AT THE TIME OF INSPECTION.
  
 2. PRIOR TO INSTALLATION, A SHORING/RESHORE GUARD RAIL
 DETAIL IS TO BE SUBMITTED FOR PLAN REVIEW. THIS SHOULD
 BE SUBMITTED WITH THE SHORING/RESHORE ENGINEERING.
  
 3. A REPLAT IS REQUIRED PRIOR TO C.O. AS THE PROPOSED
 CONSTRUCTION CROSSES PROPERTY LINE, FBC 705.8. PROVIDE
 THE BOOK AND PAGE WHERE THIS HAS BEEN RECORDED WHEN
 AVAILABLE.
  
 4. PROVISO, ACCESSIBLE MEANS OF EGRESS, FBC 5TH EDITION
 ACCESSIBILITY 207, NO METHOD SELECTED; COMPLIANCE WITH
 BOTH REQUIRED OR, IF ANY FIELD ISSUES ARISE, A REVISION
 IS REQUIRED.
  
 5. PROVISO, A SEPARATE ROOF PERMIT IS REQUIRED. PRODUCT
 APPROVALS REVIEWED BY DESIGNER OF RECORD IS TO BE
 SUBMITTED WITH A PERMIT APPLICATION. CONTRACTOR IS TO
 INDICATE ASSEMBLY PROPOSED AND, IF APPLICABLE, PROVIDE
 ENGINEERING.
  
 6. PROVISO; COMPONENT AND CLADDING TO COMPLY WITH WORST
 CASE DESIGN PRESSURES OR SUBMIT AS A REVISION; PROVIDE
 A SCHEDULE OF APPLICABLE OPENINGS AND PROPOSED
 INSTALLATION.
  
 7. PROVISO; SEPARATE PERMITS (APPLICATION, PLANS, FEES,
 REVIEW) REQUIRED FOR POOL. THE PLANS HAVE BEEN MARKED
 ?VOID? AND HAVE NOT BEEN REVIEWED.
  
 8. PROVISO; THE FOLLOWING PRODUCT APPROVALS OR SITE
 SPECIFIC ENGINEERING ARE REQUIRED TO BE SUBMITTED AS A
 REVISION AND REVIEWED PRIOR TO INSTALLATION:
  
 PRODUCT APPROVALS:
 MECHANICAL LOUVERS
 WINDOWS (WITH EXCEPTION OF NOAS ALREADY SUBMITTED)
 SERIES 8000 ALUMINUM WINDOW WALL SYSTEM (15-0727.05,
 SHEET A5.5)
 EXTERIOR DOORS
 ASSEMBLY OCCUPANCY EXTERIOR DOORS
 GENSTORM OPTION #1 LOUVER OUTSWING STEEL DOOR, DOUBLE
 (A5.4)
 OHD
 BAR TELS FRAMELESS DOORS (A5.4)
 ALL OTHER COMPONENTS AND CLADDING NOT SUBMITTED AND
 REVIEWED PRIOR TO PERMIT ISSUANCE
  
 DELEGATED ENGINEERING:
 GREEN SCREEN ALUMINUM FRAME SYSTEM
 2ND LEVEL METAL CANOPY
 TRELLIS
 SHADE STRUCTURES
 RAILINGS
 PRECAST CONCRETE (S7.0, DELEGATED ENGINEERING
 CONNECTIONS)
 PRECAST STAIRS AND LANDINGS
 AWNINGS AND CANOPIES
 OTHER DELEGATED ENGINEERING ITEMS
  
 9. PROVISO, ALL PRODUCT APPROVALS TO BE PRINTED IN AN
 EASILY LEGIBLE FORMAT (PLAN PAGES MINIMUM OF 8.5X11IN
 FULL SHEET OR, PREFERABLY 11X17).
  
 10. PROVISO, THE FOLLOWING TEST REPORTS FOR THE
 FLOORING UNDERLAYMENT WILL BE REQUIRED PRIOR TO
 INSTALLATION (INFORMATIONAL NOTE: PER S2.4, S3.1 FLOOR
 SLABS ARE 8IN, SO STC AND IIC TESTS ON AN 8IN SLAB OR
 LESS ARE ACCEPTABLE): STC (FBC 1207.2), IIC (FBC
 1207.3), ASTM E 84 (FBC 603.1).
  
 11. FS 553.79(7)(C) ALL SHORING AND RESHORING
 PROCEDURES, PLANS, AND DETAILS BE SUBMITTED TO THE
 ENFORCEMENT AGENCY FOR RECORDKEEPING. SHORING/RESHORE
 ENGINEERING IS TO BE SUBMITTED AT EACH LIFT. FAILURE TO
 SUBMIT SHORING/RESHORE PLANS TO THE BUILDING DIVISION
 FOR PLAN REVIEW AT THE TIME OF EACH LIFT MAY RESULT IN
 A STOP WORK ORDER. AS THIS ISSUE HAS BEEN PROBLEMATIC
 IN THE PAST, IT IS RECOMMENDED THAT A NOTE BE
 INCORPORATED INTO THE PLAN.
  
 12. PROVISO, ALL DOORS AND GATES IN THE MEANS OF EGRESS
 FOR ASSEMBLY OCCUPANCY SHALL HAVE PANIC DEVICES OR FIRE
 EXIT HARDWARE, FBC 1008. A REVISION INCLUDING PRODUCT
 APPROVALS WITH PANIC DEVICES PROPOSED IS TO BE
 SUBMITTED PRIOR TO INSTALLATION.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-03-10 Cont ID  
Sent By shill Date 2016-03-10 Time 16:43 Rev Time 0.00
Received By shill Date 2016-03-01 Time 16:34 Sent To  
Notes
2016-03-10 16:43:50****CORRECTIONS****
 REVISED 3/25/16
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 GOVERNING CODE: FBC 5TH EDITION (FBC 2014)
  
 1. FLORIDA STATUTE 553.71, THIS BUILDING QUALIFIES AS A
 THRESHOLD BUILDING; ANY BUILDING WHICH IS GREATER THAN
 (3) STORIES OR 50 FT. IN HEIGHT, OR WHICH HAS AN
 ASSEMBLY OCCUPANCY CLASSIFICATION AS DEFINED IN THE
 FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SF IN AREA
 AND AN OCCUPANT CONTENT OF GREATER THAN 500 PERSONS.
  
 2. AS A THRESHOLD BUILDING, THE FOLLOWING IS REQUIRED:
  
 A. THRESHOLD INSPECTION PLAN; FS 553.79(5)(A), 2010
 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION 109.3.6.1. THE
 ENFORCING AGENCY SHALL REQUIRE A SPECIAL INSPECTOR TO
 PERFORM STRUCTURAL INSPECTIONS ON A THRESHOLD BUILDING
 PURSUANT TO A STRUCTURAL INSPECTION PLAN PREPARED BY
 THE ENGINEER OR ARCHITECT OF RECORD. THE STRUCTURAL
 INSPECTION PLAN MUST BE SUBMITTED TO AND APPROVED BY
 THE ENFORCING AGENCY BEFORE THE ISSUANCE OF A BUILDING
 PERMIT FOR THE CONSTRUCTION OF A THRESHOLD BUILDING.
 THE PURPOSE OF THE STRUCTURAL INSPECTION PLAN IS TO
 PROVIDE SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO
 THAT THE BUILDING CAN BE ADEQUATELY INSPECTED FOR
 COMPLIANCE WITH THE PERMITTED DOCUMENTS.
  
 B. THRESHOLD INSPECTOR: WPB AMENDMENT 109.3.6.2 W.P.B.
 CONSTRUCTION SERVICES DEPARTMENT REQUESTS FOR THRESHOLD
 BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY FS
 553.79(5)(A) TO THE MINIMUM INSPECTIONS REQUIRED BY
 THIS CODE. THE THRESHOLD INSPECTION FORMS ARE REQUIRED
 TO BE FILED OUT BY ALL PARTIES, NOTARIZED AND RETURNED
 TO THIS OFFICE, REVIEWED AND APPROVED PRIOR TO PERMIT
 ISSUANCE. CONTACT KEN CONRAD, MANAGER OF THE SPECIAL
 INSPECTOR PROGRAM, AT 561-805-6666 FOR ADDITIONAL
 INFORMATION.
 FORMS WERE SENT TO: [email protected] ON 3/1/16.
  
 C. SPECIAL INSPECTOR RESUME': PROVIDE A RESUME' OF
 INSPECTION EXPERIENCE ON PREVIOUS PROJECTS FOR REVIEW
 BY THE BUILDING OFFICIAL OR HIS DESIGNEE. AFTER THE
 RESUME' IS REVIEWED, AN INTERVIEW WILL BE SCHEDULED.
 UNDER NO CIRCUMSTANCES WILL AN INSPECTOR BE INTERVIEWED
 FOR WORK WITHOUT FIRST MEETING THE ABOVE CRITERIA. THE
 RESUME' IS TO BE SUBMITTED TO KEN CONRAD (AND COPY
 SAMANTHA HILL), 561-805-6666, [email protected],
 [email protected]
  
 ALL PROSPECTIVE INSPECTORS ARE TO BE APPROVED BY THE
 CHIEF BUILDING INSPECTOR AND ALL ARE REQUIRED TO SIGN
 THE SPECIAL INSPECTOR AGREEMENT.
  
 D. CONTRACTOR RESUME': PROVIDE A JOB SUMMARY OR HISTORY
 FOR THIS TYPE OF CONSTRUCTION. THIS MAY BE SUBMITTED TO
 KEN CONRAD, (PLEASE COPY SAMANTHA HILL) VIA E-MAIL
 ([email protected], [email protected]).
  
 3. ADVISORY ONLY; PER FS 553.79, ALL SHORING/RE-SHORE
 ENGINEERING IS TO BE REVIEWED BY ENGINEER OF RECORD AND
 THREE SIGNED AND SEALED ORIGINAL SETS ARE TO BE
 SUBMITTED FOR PLAN REVIEW. THE SHORING/RESHORE
 ENGINEERING IS TO BE REVIEWED AND APPROVED PRIOR TO
 INSPECTION. THE CITY APPROVED (CITY STAMPED)
 SHORING/RE-SHORE ENGINEERING IS TO BE AVAILABLE ON THE
 JOB AT THE TIME OF INSPECTION.
  
 4. ADVISORY ONLY; PRIOR TO INSTALLATION, A
 SHORING/RESHORE GUARD RAIL DETAIL IS TO BE SUBMITTED
 FOR PLAN REVIEW. THIS SHOULD BE SUBMITTED WITH THE
 SHORING/RESHORE ENGINEERING.
  
 5. PRIOR TO PERMIT ISSUANCE, IMPACT FEE ASSESSMENT BY
 PALM BEACH COUNTY IS REQUIRED. PLEASE CONTACT
 561-233-5025 FOR MORE INFORMATION.
  
 6. THE PROPOSED CONSTRUCTION CROSSES PROPERTY LINE, FBC
 705.8. PLEASE ADVISE; HAS A REPLAT BEEN FILED?
  
 7. TWO DOCUMENTS WERE UPLOADED AS LAND AND TITLE SURVEY
 (003-01 AND 004-02) BUT BOTH DOCUMENTS ARE ONE PAGE,
 FIRST PAGE OF A TWO PAGE SURVEY. PROVIDE THE SECOND
 PAGE, FBC 107.
  
 8. ADVISORY ONLY; DEMOLITION OF EACH BUILDING REQUIRES
 A SEPARATE PERMIT. PLEASE SEE THE DEMOLITION PERMIT
 APPLICATION CHECKLIST ON OUR WEBSITE: HTTP://WPB.ORG/DE
 PARTMENTS/DEVELOPMENT-SERVICES/CONSTRUCTION/PERMITS
  
 9. DOOR 101 TO RESIDENTIAL LOBBY 143, PLEASE REVISE
 PLAN TO SHOW MANEUVERING CLEARANCE (18IN MINIMUM), PULL
 SIDE, SEE ANSI 117.1 FIG.B4.13.5 (PER FAIR HOUSING
 ACCESSIBILITY GUIDELINES, REQUIREMENT 3, USABLE DOORS).
  
 10. STAIR 2, A2.1 AND LS 0.1, DOES NOT HAVE A DOOR,
 WEST SIDE, SEE FBC 1022.3.1.
  
 11. LS0.1, A SURFACE MOUNT FIRE EXTINGUISHER IS
 DEPICTED ON THE RAMP (S2 TO BUSINESS/RESIDENTIAL) BUT
 DOES NOT APPEAR ON SHEET A2.1; THIS DOES NOT APPEAR TO
 COMPLY WITH FBC 1003.3, 1012.8, FBC 5TH ED.
 ACCESSIBILITY 405.5.
  
 12. FIRST FLOOR, IT IS NOT CLEAR WHICH PARKING SPACES
 SERVE THE BUSINESS OCCUPANCY AND RESIDENTIAL OCCUPANCY,
 REVISE PLAN TO CLARIFY AND SHOW COMPLIANCE WITH FBC 5TH
 EDITION ACCESSIBILITY TABLE 208.2, FHA REQUIREMENT 2.
 PROVIDE THE TOTAL NUMBER OF PARKING SPACES (FOR
 BUSINESS AND RESIDENTIAL), NUMBER OF ACCESSIBLE SPACES
 (FOR BUSINESS AND RESIDENTIAL), SHEET GA2.1. NOTE THAT
 ALL OF THE VAN ACCESSIBLE PARKING SPACES ARE ON THE
 PUBLIC SIDE OF THE VEHICLE BARRIER GATE ARM AS WELL AS
 SEVERAL ACCESSIBLE SPACES. MORE INFORMATION REGARDING
 PARKING FOR RESIDENTS AND BUSINESS VISITORS IS NEEDED.
 PLEASE FEEL FREE TO CONTACT ME TO DISCUSS.
  
 13. GA PAGES, FAIR HOUSING ACT REQUIREMENT 2,
 ACCESSIBLE AND USABLE COMMON USE AREA, STATES THAT THE
 BUILDING BE DESIGNED SO THAT THE PUBLIC AND COMMON USE
 AREAS ARE READILY ACCESSIBLE TO AND USABLE BY
 HANDICAPPED PERSONS. NONE OF THE ACCESSIBLE SPACES
 INCLUDE A CHARGING STATION, AND NONE OF THE CHARGING
 STATION SPACES INCLUDE AN ACCESS AISLE; PLEASE REVISE
 TO COMPLY WITH THIS REQUIREMENT.
  
 14. FBC 5TH EDITION ACCESSIBILITY 207, REVISE PLAN TO
 STATE WHICH METHOD OF COMPLIANCE IS ELECTED FOR
 ACCESSIBLE MEANS OF EGRESS (OFFICE SPACE).
  
 15. LS0.1, NOTE UNDER PARKING GARAGE (MECHANICALLY
 VENTILATED) STATES "AREA OF REFUGED #1", PLEASE
 CLARIFY.
  
 16. LS 0.1, REVISE PLAN TO INCLUDE GRILL AREA OCCUPANT
 LOAD, FBC 1004.
  
 17. LS 0.1, IT APPEARS THAT INTERMEDIATE HANDRAILS ARE
 REQUIRED AT THE STAIR AT DOOR 115, FBC 1012.9. REVISE
 THIS SHEET AND PROVIDE A DIMENSIONED DETAIL FOR THE
 STAIR, FBC 107.
  
 18. LS 0.1, THE HANDRAIL FOR THE RAMP IS SHOWN
 GRAPHICALLY AS A PROTRUSION INTO THE PATH OF TRAVEL.
  
 19. LS 0.1, THE CLUBHOUSE DOORS 170 AT THE VESTIBULE
 ARE DOUBLE DOORS, BUT GATE 160 IS 3FT; FBC 1005.4. SEE
 ALSO FBC 1008.2; GATES USED AS A COMPONENT IN A MEANS
 OF EGRESS SHALL CONFORM TO THE APPLICABLE REQUIREMENTS
 FOR DOORS.
  
 20. LS 0.1, REVISE PLAN TO INCLUDE THE SIDEWALK WIDTH
 FROM GATE 160 TO THE PUBLIC WAY, FBC 1005.4.
  
 21. LS 0.1, REVISE PLAN TO CLARIFY THE NUMBER OF
 OCCUPANTS EXITING THROUGH GATE 160. EXIT STAIR 4, EXIT
 STAIR 6, POOL AREA, CLUBHOUSE, 1ST FLOOR RESIDENTIAL
 LEAD TO THIS EXIT.
  
 22. LS 0.1, EXIT STRATEGY FOR POOL DECK AMENITY AREA
 AND CLUBHOUSE IS NOT CLEAR. EGRESS CAPACITY TABULATIONS
 DOES NOT INCLUDE POOL DECK AREAS; REVISE TO INCLUDE.
  
 23. LS 0.1, TOTAL OCCUPANTS IN THE POOL AREA IS 414
 (NOT INCLUDING THE GRILL AREA), WHICH REQUIRES 82.8IN
 OF EGRESS WIDTH, 1005.3.2; 68IN PROVIDED. SEE ALSO FBC
 1005.5 (REGARDING LOSS OF ONE EXIT); IT APPEARS THAT
 BOTH GATES (160, 161) ARE REQUIRED TO BE WIDER.
  
 24. LS 0.1, WILL RESIDENTS HAVE ACCESS FROM THE STREET
 SIDE OF GATE 160? THIS GATE LACKS THE MANEUVERING
 CLEARANCE REQUIRED BY ANSI 117.1 (FHA), 18IN PULL SIDE,
 ANSI 117.1 FIG.B4.13.5.
  
 25. LS 0.1, IT IS NOT CLEAR IF GATE 160A HAS THE
 MANEUVERING CLEARANCE REQUIRED BY ANSI 117.1 (FHA),
 18IN PULL SIDE, ANSI 117.1 FIG.B4.13.5. REVISE PLAN TO
 CLARIFY.
  
 26. LS 0.2 AND OTHER SHEETS, A SURFACE MOUNT FIRE
 EXTINGUISHER IS SHOWN WHERE IT APPEARS TO OBSTRUCT THE
 ACCESSIBLE PARKING ACCESS AISLE. PROVIDE DIMENSIONS TO
 SHOW THAT THE ACCESS AISLE IS NOT OBSTRUCTED.
  
 27. LS 0.2, LS 0.4, UNITS A1 AND C2, TENANT / OCCUPANCY
 SEPARATION BETWEEN THE R2 UNITS AND THE A2 CORRIDOR IS
 LACKING, FBC TABLE 508.4.
  
 28. LS 0.4, THE DOORS SERVING THE NORTH ROOF DECK ARE
 TO SWING IN THE DIRECTION OF EGRESS TRAVEL, FBC
 1008.1.10.
  
 29. LS 0.4 IS LABELED LEVELS 4 THROUGH 7, BUT THE 4TH
 FLOOR IS NOT THE SAME AS FLOORS 5 THROUGH 7, PLEASE
 CORRELATE.
  
 30. LS 0.5, UNIT C1 TO CORRIDOR LACKS THE 1 HOUR RATING
 REQUIRED BY FBC 1018, PLEASE REVISE.
  
 31. SHEET S1 2A, SPECIFY FLOOR LOADS FOR THE ASSEMBLY
 AREAS (CLUBHOUSE ROOF DECK, GYM, EXERCISE ROOM).
  
 33. SHEET A2.9 SPECS MIAMI DADE NOAS 14-0618.03,
 13-0529.02 (JM TPO) ROOF SYSTEM. ADVISORY ONLY; A
 SPECIFIC REFERENCE TO A ROOFING PRODUCT WILL REQUIRE A
 REVISION IF A DIFFERENT PRODUCT IS SELECTED AT TIME OF
 INSTALLATION. IT IS RECOMMENDED THAT, IF UNSURE OF
 FINAL PRODUCT TO BE INSTALLED, REFERENCES ARE LEFT OFF
 OF THE PLAN AND PRODUCT APPROVALS (REVIEWED BY DESIGNER
 OF RECORD) SUBMITTED PRIOR TO INSTALLATION. THIS
 COMMENT DOES NOT NEED TO BE ADDRESSED SUBJECT TO
 DESIGNER?S DISCRETION.
  
 34. ROOF PRODUCT APPROVALS WERE SUBMITTED BUT THE
 ASSEMBLY PROPOSED WAS NOT SELECTED AND ENGINEERING FOR
 ENHANCED FASTENING WAS NOT PROVIDED. IF THIS
 INFORMATION IS NOT PROVIDED AT THIS TIME, THE
 INFORMATION WILL BE REQUIRED AT TIME OF ROOF SUB PERMIT
 SUBMITTAL.
  
 35. DETAIL 9-A2.9 SPECIFIES PLYWOOD SHEATHING; 1-S4.1
 SPECS WOOD FRAMED CANOPY (ALSO OTHER DETAILS THROUGH
 PLANS). PLEASE SEE FBC 603 AND REVISE.
  
 36. S6.0, WALL PRESSURES SPECIFIED AND SOME PRODUCT
 APPROVALS WERE SUBMITTED BUT THE CHART IS A GENERAL
 ONE, NOT SPECIFIC TO EACH OPENING. THE PRODUCT
 APPROVALS ARE NOT MARKED TO INDICATE WHICH OF THE
 OPTIONS IS PROPOSED. EITHER PROVIDE A SCHEDULE TO SHOW
 DESIGN PRESSURES FOR EACH OPENING AND PRODUCT APPROVALS
 MARKED TO SHOW WHICH OPTION PROPOSED FOR EACH OPENING
 (OR ONE TO BE USED FOR ALL OPENINGS TO COMPLY WITH
 WORST CASE), OR THIS WILL BE A PROVISO ITEM (PROVIDE
 FOR REVIEW PRIOR TO INSTALLATION).
  
 37. DETAIL 1-S4.1, PROVIDE A DETAIL FOR THE SOFFIT (OR
 ADVISE AS TO WHERE THIS INFORMATION IS LOCATED). PLAN
 STATES ?STUCCO & OTHER FINISHES, REF. ARCHITECTURAL.?
  
 38. SHEET S1.9A IS INCORRECTLY NAMED AS 8TH FLOOR
 PARTIAL PLAN (BUT IS A PARTIAL ROOF PLAN), PLEASE
 ADDRESS.
  
 39. SHEET S6.1 STATES THAT PARAPET PRESSURES ARE BASED
 ON A SOLID PARAPET WITH NO INTERNAL PRESSURE AND THAT
 INTERNAL PRESSURE MAY NEED TO BE ADDED. THE PARAPETS
 SHOWN ON S4.1 ARE WOOD FRAME. IT APPEARS THAT SOME OF
 THE PARAPETS ARE NOT SOLID. PLEASE INCLUDE PARAPET
 DESIGN PRESSURES FOR FRAME PARAPETS.
  
 40. DETAIL 6-4.0, 1-S7.0 SPECIFIES A LINTEL, BUT I WAS
 UNABLE TO LOCATE A LINTEL SCHEDULE, FBC 16, FBC 107,
 PLEASE DIRECT OR REVISE TO INCLUDE LINTEL
 SPECIFICATION.
  
 41. SEE PLUMBING COMMENTS REGARDING FAIR HOUSING. ALL
 COMMENTS ARE ALSO APPLICABLE FOR BUILDING REVIEW.
  
 42. SEE MECHANICAL COMMENTS REGARDING ENERGY CALCS. ALL
 COMMENTS ARE ALSO APPLICABLE FOR BUILDING REVIEW.
  
 43. SHEET LS 0.1 STATES THAT STAIRS ARE PRESSURIZED BUT
 I WAS UNABLE TO LOCATE STAIR PRESSURIZATION DETAILS,
 PLEASE CLARIFY.
  
 44. A5.3.1, ITEM 22, WOOD COMPOSITE PANELS ON METAL
 CHANNELS, PLEASE ADVISE; IS THIS APPLICABLE FOR THIS
 JOB, AND WHERE? FBC 603.
  
 45. A5.4, SEE FBC TABLE 716.5, DOORS 106, 106A ARE
 REQUIRED TO HAVE A 1.5 HR RATING AS THEY ARE LOCATED IN
 A 2 HOUR WALL, 45 MINUTES SPECIFIED. DOOR 110 ON THE
 PLAN IS DEPICTED IN A 1 HOUR WALL, BUT THE DOOR
 SCHEDULE DOES NOT SPECIFY A FIRE RATING. CHECK ALL AND
 REVISE AS NECESSARY PRIOR TO RESUBMITTAL.
  
 46. FBC 501.2, ADDRESS IDENTIFICATION REQUIRED.
  
 47. THE SOILS REPORT IS NOT DIGITALLY SIGNED. THE
 REPORT ALSO LACKS THE ENGINEERING COMPANY CERTIFICATE
 OF AUTHORIZATION ON THE DOCUMENT. PLEASE REVISE TO
 INCLUDE. IF THE ENGINEER (RAMAKUMAR V. VEDULA, PE) HAS
 A DIGITAL SIGNATURE, PLEASE PROVIDE A DIGITALLY SIGNED
 SOILS REPORT. IF THE ENGINEER DOES NOT HAVE A DIGITAL
 SIGNATURE, PLEASE PROVIDE AN ORIGINAL SIGNED AND SEALED
 SOILS REPORT. FS471, FAC61G15.
  
 THE STRUCTURAL CALCS ARE NOT DIGITALLY SIGNED; PLEASE
 ADDRESS.
  
 48. PRODUCT APPROVALS ARE TO BE REVIEWED BY DESIGNER OF
 RECORD, FBC 107. IF THE DESIGNER DOES NOT HAVE A
 REFERENCE IN THE PLAN TO A SPECIFIC PRODUCT, A SHOP
 DRAWING REVIEW STAMP ON EACH PRODUCT APPROVAL OR A
 LETTER IS REQUIRED. THE ROOF PRODUCT APPROVALS AND SOME
 WINDOWS AND DOORS (A4.7) ARE SPECIFICALLY REFERENCED IN
 THE PLAN SO DO NOT REQUIRE DOR REVIEW STAMP. FOR ALL
 OTHER ITEMS, PLEASE PROVIDE EVIDENCE OF DOR REVIEW.
  
 49. NOA 14-0923.10 (AND OTHER PRODUCT APPROVALS) WERE
 PRINTED AND UPLOADED WITH THE DRAWING PAGES REDUCED TO
 HALF SIZE. THIS RESULTS IN ILLEGIBLE PRODUCT APPROVALS
 WHEN PRINTED. PRODUCT APPROVALS IN THE FIELD ARE
 REQUIRED FOR INSPECTION PURPOSES. PLEASE REPRINT THE
 DRAWING PAGES IN LANDSCAPE ORIENTATION AND UPLOAD. THE
 PAGES ON THE MIAMI DADE WEBSITE ARE DESIGNED TO BE
 PRINTED 11X17, SO THE PAGES PROVIDED ARE 25% OF THE
 INTENDED SIZE. CHECK ALL PRODUCT APPROVALS AND UPLOAD
 AS NEEDED. PLEASE CONTACT ME IF YOU NEED ADDITIONAL
 INFORMATION.
  
 50. ADVISORY ONLY; SOME (BUT NOT ALL) PRODUCT APPROVALS
 HAVE BEEN SUBMITTED. APPLICANT MAY ELECT TO DEFER
 PRODUCT APPROVAL SUBMITTAL. THEY CAN BE SUBMITTED AFTER
 PERMIT ISSUANCE, PRIOR TO INSTALLATION, WITH NO
 ADDITIONAL FEES.
  
 51. SEE ROOF REVIEW COMMENTS:
  
 ROOF NOAS FOR JM TPO SUBMITTED; 14-0618.03, 13-0529.02
  
 A. ROOF PRODUCT APPROVALS WERE SUBMITTED BUT THE
 ASSEMBLY PROPOSED WAS NOT SELECTED AND ENGINEERING FOR
 ENHANCED FASTENING (WOOD DECK) WAS NOT PROVIDED. IF
 THIS INFORMATION IS NOT PROVIDED PRIOR TO PERMIT
 ISSUANCE, THE INFORMATION WILL BE REQUIRED AT TIME OF
 ROOF SUB PERMIT SUBMITTAL. AN "N" WILL BE ENTERED FOR
 THE ROOF PLAN REVIEW.
  
 ROOF ASSEMBLIES SELECTED TO COMPLY WITH THE (VULT)
 PRESSURES SPECIFIED ON SHEET S6-1.
  
 B. SHEET S6-1, CLARIFY THE DIFFERENCE BETWEEN THE "ROOF
 MEMBRANE DESIGN PRESSSURE" VS. "GROSS UPLIFT DESIGN
 PRESSURES." THE DESIGN PRESSURES TO BE UTILIZED FOR THE
 TPO ROOF IS NOT CLEAR.
  
 C. SHEET S6-1, IT APPEARS THAT ROOF PRESSURES SPECIFIED
 USE ZONE 2 PRESSURES FOR ZONE 3. THE STAIR ROOFS,
 ELEVATOR ROOFS, CANOPIES (DETAIL 1-S4.1, A SHEETS
 BUILDING SECTIONS, OTHER PLACES) DO NOT INCLUDE A 3FT
 PARAPET, FBC 1609, ASCE7 10 30.6-1 NOTE 7. SEE ALSO
 ROOF REVIEW COMMENTS. IT IS NOT CLEAR WHICH DESIGN
 PRESSURES ARE SPECIFIED FOR THE ROOF.
  
 D. PLAN SHEET S1.9C AND OTHER SHEETS INCLUDE AN
 INDICATOR FOR DETAIL 1 S9.1A; UNABLE TO LOCATE THIS
 SHEET (S9.1A). PLEASE PROVIDE SHEET OR REVISE DETAIL
 INDICATOR TO CORRECT LOCATION.
  
  
 52. ADVISORY ONLY, THE ART IN PUBLIC PLACES WAS SENT
 VIA EMAIL, CITY OF WEST PALM BEACH CODE OF ORDINANCES
 78-123, 78-126.
  
 THIS PERMIT WILL BE ISSUED WITH THE PROVISO THAT,
 WITHIN 90 DAYS OF ISSUANCE, THE APPROVAL WILL BE
 PROVIDED. PLEASE SEND A COPY OF THE APPROVAL WHEN
 AVAILABLE VIA EMAIL TO [email protected] IN ORDER TO
 DOCUMENT THE PERMIT FILE.
  
 PLEASE VERIFY THAT APPLICANT UNDERSTANDS THE
 REQUIREMENTS. PLEASE FEEL FREE TO CONTACT ME FOR MORE
 INFORMATION.
  
 53. PROVISO; SEPARATE PERMITS (APPLICATION, PLANS,
 FEES, REVIEW) REQUIRED FOR POOL. THE PLANS HAVE BEEN
 MARKED ?VOID? AND HAVE NOT BEEN REVIEWED.
  
 54. PROVISO; THE FOLLOWING PRODUCT APPROVALS OR SITE
 SPECIFIC ENGINEERING ARE REQUIRED TO BE SUBMITTED AND
 REVIEWED PRIOR TO INSTALLATION:
  
 MECHANICAL LOUVERS
 WINDOWS
 SERIES 8000 ALUMINUM WINDOW WALL SYSTEM (15-0727.05,
 SHEET A5.5)
 DOORS
 GENSTORM OPTION #1 LOUVER OUTSWING STEEL DOOR, DOUBLE
 (A5.4)
 OHD
 BAR TELS FRAMELESS DOORS (A5.4)
 ALL OTHER COMPONENTS AND CLADDING NOT SUBMITTED AND
 REVIEWED PRIOR TO PERMIT ISSUANCE
  
 GREEN SCREEN ALUMINUM FRAME SYSTEM
 2ND LEVEL METAL CANOPY
 TRELLIS
 SHADE STRUCTURES
 RAILINGS
 PRECAST CONCRETE (S7.0, DELEGATED ENGINEERING
 CONNECTIONS)
 PRECAST STAIRS AND LANDINGS
 AWNINGS AND CANOPIES
 OTHER DELEGATED ENGINEERING ITEMS
  
 55. PROVISO, THE FOLLOWING TEST REPORTS FOR THE
 FLOORING UNDERLAYMENT WILL BE REQUIRED PRIOR TO
 INSTALLATION (INFORMATIONAL NOTE: PER S2.4, S3.1 FLOOR
 SLABS ARE 8IN, SO STC AND IIC TESTS ON AN 8IN SLAB OR
 LESS ARE ACCEPTABLE): STC (FBC 1207.2), IIC (FBC
 1207.3), ASTM E 84 (FBC 603.1).
  
 56. ADVISORY ONLY, FS 553.79(7)(C) ALL SHORING AND
 RESHORING PROCEDURES, PLANS, AND DETAILS BE SUBMITTED
 TO THE ENFORCEMENT AGENCY FOR RECORDKEEPING.
 SHORING/RESHORE ENGINEERING IS TO BE SUBMITTED AT EACH
 LIFT. FAILURE TO SUBMIT SHORING/RESHORE PLANS TO THE
 BUILDING DIVISION FOR PLAN REVIEW AT THE TIME OF EACH
 LIFT MAY RESULT IN A STOP WORK ORDER. AS THIS ISSUE HAS
 BEEN PROBLEMATIC IN THE PAST, IT IS RECOMMENDED THAT A
 NOTE BE INCORPORATED INTO THE PLAN.
  
 57. ADVISORY ONLY, WINDOW AND DOOR PRODUCT APPROVALS
 SPECIFIED ON SHEET A4.7:
 NOAS 15-0611.10, 15-0629.01, 13-0617.28, 14092309.09
 SPECIFIED. CHANGES FROM THE WINDOW AND DOORS SPECIFIED
 WILL REQUIRE A REVISION (REVISED PLAN SHEET, NEW
 PRODUCT APPROVALS).
  
 58. A2.1, THE DOOR FOR UNIT 140 AND OTHER UNITS ARE NOT
 LABELED, FBC 107. THE INDEX SHOWS A DOOR SCHEDULE FOR
 THE AMENITY AREA. PLEASE ADVISE AS TO WHERE THE UNIT
 ENTRY DOOR SCHEDULE IS LOCATED OR PROVIDE.
  
 59. FBC 424.1.3.1.9, 424.2.17, POOL BARRIER PROPOSED IS
 NOT CLEAR (WINDOWS LOCATED IN THE WALL WHICH SERVES AS
 THE POOL BARRIER).
  
 60. SHEET A6.1, ITEM 68 SPECIFIES RIGID INSULATION, NOA
 11-0516.02; THIS IS THE NOA NUMBER FOR WATERPROOFING,
 REVISE; ALSO SEE OTHER COMMENTS REGARDING NOA NUMBERS
 ON THE PLAN.
  
 61. PROVIDE A GRAB BAR BACKING DETAIL, FBC 107.
  
 62. FHA, NOT ALL OF THE SLIDING GLASS DOORS PROPOSED
 ARE 6FT; FOR INSTANCE, SEE UNIT S2, SHEET A4.1. SEE
 PAGE 3.10 OF THE FAIR HOUSING ACT DESIGN MANUAL AND THE
 GUIDANCE REGARDING SLIDING GLASS PATIO DOORS (SECONDARY
 DOOR) AND REVISE PLAN TO DEMONSTRATE COMPLIANCE.
  
  
 63. DETAIL 2-S4.1 GRAPHICALLY DEPICTS AN EMBEDDED STRAP
 BUT DOES NOT SPECIFY. PLEASE EITHER PROVIDE INFORMATION
 AS TO WHERE THIS INFORMATION CAN BE FOUND OR REVISE
 PLAN TO SPECIFY CONNECTORS.
  
 64. DETAILS 1 AND 2, S4.1, PLEASE PROVIDE DIRECTION AS
 TO WHICH PLAN VIEW SHEET THE DETAIL INDICATOR FOR THESE
 DETAILS ARE LOCATED.
  
 65. FIRST FLOOR (LS 0.1 AND OTHER SHEETS), ADJACENT TO
 STAIR 3, A RAMP IS SHOWN BUT NO STAIR TO ACCESS THE
 RESIDENTIAL CORRIDOR FROM THE GARAGE. IT IS SUGGESTED
 THAT AN ACCESSIBLE STAIR BE ADDED. THE RAMP ADDS
 DISTANCE TO THE PATH OF TRAVEL WHICH COULD BE A
 HARDSHIP FOR SOMEONE WHO IS DISABLED OR COMPROMISED,
 DOES NOT USE A WHEELCHAIR AND IS ABLE TO NAVIGATE A
 STAIR.
  
 66. SEE THE ROOF REVIEW:
  
 ROOF NOAS FOR JM TPO SUBMITTED; 14-0618.03, 13-0529.02
  
 A. ROOF PRODUCT APPROVALS WERE SUBMITTED BUT THE
 ASSEMBLY PROPOSED WAS NOT SELECTED AND ENGINEERING FOR
 ENHANCED FASTENING (WOOD DECK) WAS NOT PROVIDED. IF
 THIS INFORMATION IS NOT PROVIDED PRIOR TO PERMIT
 ISSUANCE, THE INFORMATION WILL BE REQUIRED AT TIME OF
 ROOF SUB PERMIT SUBMITTAL. AN "N" WILL BE ENTERED FOR
 THE ROOF PLAN REVIEW.
  
 ROOF ASSEMBLIES SELECTED TO COMPLY WITH THE (VULT)
 PRESSURES SPECIFIED ON SHEET S6-1.
  
 B. SHEET S6-1, CLARIFY PURPOSE OF "ROOF MEMBRANE DESIGN
 PRESSSURE" VS. "GROSS UPLIFT DESIGN PRESSURES." THE
 DESIGN PRESSURES TO BE UTILIZED FOR THE TPO ROOF IS NOT
 CLEAR.
  
 C. SHEET S6-1, ROOF PRESSURES SPECIFIED USE ZONE 2
 PRESSURES FOR ZONE 3. IT APPEARS THAT THE STAIR ROOF,
 ELEVATOR ROOF DO NOT INCLUDE A 3FT PARAPET, FBC 1609,
 ASCE7 10 30.6-1 NOTE 7.
  
  
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2016-10-25 Cont ID  
Sent By vperez Date 2016-10-25 Time 14:54 Rev Time 0.00
Received By vperez Date 2016-10-25 Time 14:54 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2016-08-15 Cont ID  
Sent By albarran Date 2016-08-15 Time 14:49 Rev Time 0.00
Received By albarran Date 2016-08-15 Time 12:46 Sent To  
Notes
2016-08-15 14:49:50STAMPED NEW SHEETS PREVIOUSLY REVIEWED AND APPROVED BY
 VP

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-06-16 Cont ID  
Sent By vperez Date 2016-06-16 Time 15:00 Rev Time 0.00
Received By vperez Date 2016-06-16 Time 15:00 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-02-24 Cont ID  
Sent By vperez Date 2016-02-24 Time 05:25 Rev Time 0.00
Received By vperez Date 2016-02-24 Time 05:25 Sent To  
Notes
2016-02-24 05:25:43INITIAL ELECTRICAL PLAN REVIEW
  
 APPLICABLE CODES IN EFFECT:
 FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70- 2011 NEC
 COMMENTS:
  
 1. SHEET LT-1- PROVIDE A BLOCK NOTE INDICATING THE
 REQUIRED SEPARATE PERMITS AND DATA CUT SHEET SUBMITTALS
 FOR ALL SITE LIGHTING AND ASSOCIATED EQUIPMENT. A NOTE
 WILL SUFFICE.
 2. GENERAL NOTES- PROVIDE A BLOCK NOTE INDICATING THE
 REQUIRED SEPARATE PERMITS AND DATA CUT SHEET SUBMITTALS
 FOR FIRE PUMP ALL LOW VOLTAGE SYSTEMS TO INCLUDE BUT
 NOT LIMITED TO FIRE ALARM, ACCESS CONTROLS, CCTV, PHONE
 AND DATA, SIGNAGE, WIRELESS SYSTEMS, CAR CHARGING
 STATIONS, ETC. A NOTE WILL SUFFICE.
 3. PLEASE PROVIDE DATA SHEETS FOR THE EMERGENCY
 INVERTERS SHOWN ON DESIGN. FBC 107.3.5
 4. SHOW TWO MEANS OF ACCESS AND EGRESS FOR THE MAIN
 ELECTRICAL ROOM #1. COULD NOT DETERMINE SIZE OF THE
 ELECTRICAL EQUIPMENT IN ROOM. NEC 110.26C2
 5. SHEET E3.3- PLEASE LABEL RECEPTACLE IN WORK ROOM TO
 BE GFCI PROTECTED PER NEC 210.8B5- IF WITHIN 6FT OF
 SINK ALL TO BE GFCI.
 6. SHEET E3.5- PLEASE LABEL RECEPTACLE IN KITCHEN AND
 PRIVATE LOUNGE TO BE GFCI PROTECTED PER NEC 210.8B5- IF
 WITHIN 6FT OF SINK, ALL TO BE GFCI.
 7. ON UNIT PLANS DRAWINGS CORRECT TYPO ON APARTMENT
 FEEDER SCHEDULE TO INDICATE ALUMINUM CONDUCTORS BEING
 USED NOT COPPER. PLEASE CORRELATE FBC 107.3.5
 8. SHEET E5.2- RISER DIAGRAM; PLEASE CLARIFY MAIN 2 OF
 2 3500A MCB WITH 6 SETS OF 600 ALUMINUM WIRES. 600AL IS
 GOOD FOR 340AMP AT 75 DEGREE TERMINAL RATINGS, NEC
 310.15B16. UNDERSIZED AS SHOWN FOR A 3500 MCB. CLARIFY
 AND CORRECT.
 9. NOTE THAT PER NEC 230.2 THIS PROJECT MEETS THE
 REQUIREMENTS FOR MULTIPLE SERVICES DUE TO CAPACITY
 LIMITS. REGARDLESS, SPECIAL PERMISSION FROM AHJ TO BE
 GRANTED PER DESIGN SHOWN. PROVIDE IN WRITING A REQUEST
 PER CODE SECTION CITED TO AHJ. GENERAL NOTES TO BE
 PLACED FOR FIRST RESPONDERS SAFETY. FIRE REVIEW MIGHT
 REQUIRE OTHER MEANS TO SHUNT SERVICES. FBC 107.3.5
 10. PROVIDE FROM UTILITY PROVIDER (FPL), ACTUAL
 AVAILABLE FAULT CURRENT AT THE TRANSFORMERS. NOTE NOT
 SUFFICIENT AT THIS TIME. FBC 107.3.5
 11. PROVIDE AIC CALCULATION PER NEC 110.10- FBC 107.3.5
 12. PROVIDE A NOTE/SIGN TO INDICATE THE REQUIREMENTS
 NEC 110.24 THE MAX. AVAILABLE FAULT CURRENT SHALL BE
 DURABLY MARKED AND DATED ON ALL ELECTRICAL APPARATUS
 AND NEC 110.16 ARC-FLASH HAZARD WARNING LABELS
 REQUIRED.
 13. PER FBC EC 405.7.3- SHOW VOLTAGE DROP CALCULATIONS
 FOR FEEDERS AND BRANCH CIRCUITS.
 14. CLARIFY SELECTION OF SERVICE AND FEEDER CONDUCTORS
 AS SHOWN ON RISER DIAGRAM. FOR EXAMPLE PANEL 3UDP SHOWS
 A 3500A MCB WITH SERVICE CONDUCTORS SIZED AT 2040AMP (2
 SETS OF 4#600 AL.). THE CALCULATED LOADS ON SHEET E5.01
 FOR THE METER CENTERS IS SHOWN AT 608+680=(1288) * 2=
 2576AMPS DEMAND LOADS. PLEASE REVISIT LOADS AND
 CONDUCTOR SIZES AS SHOWN. SEE NEC 240.4C- PROTECTION OF
 CONDUCTORS. NEC 310.15B16 TABLE OF AMPACITIES BASED ON
 75 DEGREE COLUMN FOR TERMINAL RATINGS. NEC 110.14C.
 VERIFY ENTIRE RISER DIAGRAM.
 15. COMMENTS MAY FOLLOW UPON RE-REVIEW. PLEASE FEEL
 FREE TO CONTACT ME SHOULD YOU HAVE ANY QUESTIONS
 REGARDING THIS PROJECT.
  
  
 VALENTINO PEREZ
 ELECTRICAL PLANS EXAMINER II
 561-805-6717
 [email protected]
  
  
  
  
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2016-07-20 Cont ID  
Sent By Mgonzale Date 2016-07-20 Time   Rev Time 0.00
Received By mgonzale Date 2016-07-20 Time   Sent To Z
Notes
2016-07-20 08:55:16NO OBJECTION, PRJECT HAS FORMALLY BEEN SUBMITTED THRU
 ENGINEERING.
  
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 PUBLIC WORKS DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
 IMPORTANT MESSAGE: AS OF DECEMBER 20, 2015 THE CITY OF
 WEST PALM BEACH
 CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED,
 MAKING KNOWN THAT "ALL BACKFLOW DEVICES MUST BE LEAD
 FREE."
 FOR MORE INFORMATION REFER TO THE LINK BELOW:
 HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLI
 CATIONS/BACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL
  
  
  
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2016-03-31 Cont ID  
Sent By Mgonzale Date 2016-03-31 Time   Rev Time 1.00
Received By mgonzale Date 2016-03-31 Time   Sent To I
Notes
2016-03-31 19:43:27PLAN REVISIONS WILL HAVE TO BE SUBMITTED TO REFLECT
 CITY OF WEST PALM BEACH ENGINEERING DEVELOPMENT REVIEW
 SUBMITTAL.
  
 [email protected]
2016-03-16 14:10:18ENGINEERING REVIEW WILL BE PERFORMED DURING THE 2ND
 REVIEW CYCLE.

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2016-09-01 Cont ID  
Sent By rlindow Date 2016-08-31 Time   Rev Time 0.00
Received By rlindow Date 2016-08-29 Time   Sent To  
Notes
2016-08-29 15:53:53 
  
 8/29/2016
 R. LINDOW
  
  
 APPROVED WITH THE FOLLOWING PROVISO:
  
 1) THE FIRE PLACE IS NOT APPROVED AT THIS TIME. PROVIDE
 ADDITIONAL INFORMATION ON GAS APPLIANCE TO COMPLY WITH
 ALL APLICABLE REQUIREMENTS. THIS SHOULD INCLUDE
 OPERATIONAL SAFE GUARDS, MAINTENANCE PROCESSES,
 ETC......
  
 2) SHEET 039-LS-0.1 ADD ADDITIONAL DOOR/ GATE TO
 ACCOMODATE OCCUPANT LOAD AT NORTH EXIT FROM POOL AREA.
  
 3) "NO PARKING FIRE LANE" SIGNAGE IS REQUIRED. SEE
 SHEET 012-C-09
  
 4) THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF
 THE 5TH EDITION OF FLORIDA FIRE PREVENTION CODE
 INCLUDING THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND
 ALL OTHER APPLICABLE CODES OR STANDARDS.
  
 5) SEPARATE PLANS AND PERMITS NEEDED FOR PRIVATE
 UNDERGROUND FIRE LINE AND FIRE HYDRANTS.
  
 6) EMERGENCY ILLUMINATION SHALL BE PROVIDED FOR A
 MINIMUM OF 1.5 HOURS IN THE EVENT OF FAILURE OF NORMAL
 LIGHTING. EMERGENCY LIGHTING FACILITIES SHALL BE
 ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS NOT
 LESS THAN AN AVERAGE OF 1 FT-CANDLE AND, AT ANY POINT,
 NOT LESS THAN 0.1 FT-CANDLE, MEASURED ALONG THE PATH OF
 EGRESS AT FLOOR LEVEL.
  
 7)PER SECTION 7.2.2.5.4 - STAIRWAY IDENTIFICATION: NEW
 ENCLOSED STAIRS SERVING THREE OR MORE STORIES AND
 EXISTING ENCLOSED STAIRS SERVING FIVE OR MORE STORIES
 SHALL COMPLY WITH (A) THROUGH (L).
 (A) THE STAIRS SHALL BE PROVIDED WITH SPECIAL SIGNAGE
 WITHIN THE ENCLOSURE AT EACH FLOOR LANDING.
 (B) THE SIGNAGE SHALL INDICATE THE FLOOR LEVEL.
 (C) THE SIGNAGE SHALL INDICATE THE TERMINUS OF THE TOP
 AND BOTTOM OF THE STAIR ENCLOSURE.
 (D) THE SIGNAGE SHALL INDICATE THE IDENTIFICATION OF
 THE STAIR ENCLOSURE.
 (E) THE SIGNAGE SHALL INDICATE THE FLOOR LEVEL OF, AND
 THE DIRECTION TO, EXIT DISCHARGE.
 (F) THE SIGNAGE SHALL BE LOCATED INSIDE THE ENCLOSURE
 APPROXIMATELY 60-INCHES ABOVE THE FLOOR LANDING IN A
 POSITION THAT IS VISIBLE WHEN THE DOOR IS IN THE OPEN
 OR CLOSED POSITION.
 (G) THE FLOOR LEVEL DESIGNATION SHALL ALSO BE TACTILE.
 (H) THE SIGNAGE SHALL BE PAINTED OR STENCILED ON THE
 WALL OR ON A SEPARATE SIGN SECURELY ATTACHED TO THE
 WALL.
 (I) THE STAIRWAY IDENTIFICATION LETTER SHALL BE LOCATED
 AT THE TOP OF THE SIGN IN MINIMUM 1-INCH HIGH
 LETTERING.
 (J) SIGNAGE THAT READS ?NO ROOF ACCESS? AND IS LOCATED
 UNDER THE STAIRWAY IDENTIFICATION LETTER SHALL
 DESIGNATE STAIRWAYS THAT DO NOT PROVIDE ROOF ACCESS.
 LETTERING SHALL BE A MINIMUM OF 1-INCH HIGH.
 (K) THE FLOOR LEVEL NUMBER SHALL BE LOCATED IN THE
 MIDDLE OF THE SIGN IN MINIMUM 5-INCH HIGH NUMBERS.
 MEZZANINE LEVELS SHALL HAVE THE LETTER ?M? OR OTHER
 APPROPRIATE IDENTIFICATION LETTER PRECEDING THE FLOOR
 NUMBER, WHILE BASEMENT LEVELS SHALL HAVE THE LETTER ?B?
 OR OTHER APPROPRIATE IDENTIFICATION LETTER PRECEDING
 THE FLOOR LEVEL NUMBER.
 (L) IDENTIFICATION OF THE LOWER AND UPPER TERMINUS OF
 THE STAIRWAY SHALL BE LOCATED AT THE BOTTOM OF THE SIGN
 IN MINIMUM 1-INCH HIGH LETTERS OR NUMBERS.
  
 8) WET FIRE HYDRANTS ARE REQUIRED PRIOR TO, DURING AND
 AFTER CONSTRUCTION.
  
 9) WHERE THE MOST REMOTE PORTION OF A NONSPRINKLERED
 FLOOR OR STORY IS LOCATED IN EXCESS OF 150 FT (45.7 M)
 OF TRAVEL DISTANCE FROM A REQUIRED EXIT CONTAINING OR
 ADJACENT TO A HOSE CONNECTION OR THE MOST REMOTE
 PORTION OF A SPRINKLERED FLOOR OR STORY IS LOCATED IN
 EXCESS OF 200 FT (61 M) OF TRAVEL DISTANCE FROM A
 REQUIRED EXIT CONTAINING OR ADJACENT TO A HOSE
 CONNECTION,
 ADDITIONAL HOSE CONNECTIONS SHALL BE PROVIDED, IN
 APPROVED LOCATIONS, WHERE REQUIRED BY THE LOCAL FIRE
 DEPARTMENT OR THE AHJ.
  
 10) NFPA 13, A BUILDING, WHERE PROTECTED BY AN
 AUTOMATIC SPRINKLER SYSTEM INSTALLATION, SHALL BE
 PROVIDED WITH SPRINKLERS IN ALL AREAS EXCEPT WHERE
 SPECIFIC SECTIONS OF THIS STANDARD PERMIT THE OMISSION
 OF SPRINKLERS.
  
 11) THE CITY OF WEST PALM BEACH REQUIRES CONSTRUCTION
 TRAILERS LARGER THAN A SINGLE "DOUBLE WIDE" (OR TWO
 "SINGLE WIDE") TO EITHER BE PROTECTED BY AN AUTOMATIC
 SPRINKLER SYSTEM OR COMPLY WITH THE SEPARATION
 REQUIREMENTS OF NFPA 241. TEMPORARY CONSTRUCTION
 TRAILERS OR MODULAR BUILDINGS WILL REQUIRE A PERMIT AND
 COMPLIANCE WITH THE FOLLOWING:
 PER NFPA 241- STANDARD FOR SAFEGUARDING CONSTRUCTION,
 ALTERATION, AND DEMOLITION OPERATIONS, SECTION 4.2:
 TEMPORARY OFFICES, TRAILERS, AND OTHER FACILITIES OF
 COMBUSTIBLE CONSTRUCTION OR HOUSING COMBUSTIBLE
 CONTENTS SHALL BE SEPARATED FROM ADJACENT BUILDINGS,
 TRAILERS OR STRUCTURES IN ACCORDANCE WITH TABLE 4.2.1.
 PER TABLE 4.2.1:
 1) 20 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 30 FEET
 2) 30 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 35 FEET
 3) 40 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 40 FEET
 4) 50 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 45 FEET
 5) 60 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 50 FEET
 6) GREATER THAN 60 FEET EXPOSED LENGTH SHALL BE
 SEPARATED FROM ADJACENT STRUCTURES BY AT LEAST 60 FEET
 **A 75 PERCENT REDUCTION IN SEPARATION DISTANCES SHALL
 BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC
 SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE.
  
 PER NFPA 241 SECTION 4.2.2: DETACHMENT BETWEEN
 TEMPORARY STRUCTURES, ADEQUATE TEMPORARY FIXED FIRE
 PROTECTION SYSTEMS, AND PORTABLE EQUIPMENT SHALL BE
 PROVIDED AS REQUIRED BY THE AUTHORITY HAVING
 JURISDICTION.
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2016-06-23 Cont ID  
Sent By rlindow Date 2016-06-23 Time   Rev Time 0.00
Received By rlindow Date 2016-06-23 Time   Sent To  
Notes
2016-06-23 15:20:27ROY LINDOW-6/23/16
 FIRE PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
  
 1) SHEET 20?M3.1C, THIS SHEET SHOWS KITCHEN RANGE ON
 DRAWING. THE EXHAUST HOOD SHOWN ON PLANS IS NOT SHOWN
 OVER RANGE. KITCHEN EXHAUST AND FIRE SUPPRESSION SYSTEM
 REQUIRE SEPARATE PERMIT AND DRAWINGS.
 2) SHEET 094-A-5.4 & SHEET 095-A-5.4.1 DOOR SCHEDULE,
 THE REMARKS KEY DOES NOT SHOW A SEPARATE KEY ITEM FOR
 LISTED FIRE EXIT HARDWARE. PROVIDE A KEY FOR ALL FIRE
 RATED DOORS TO HAVE LISTED FIRE EXIT HARDWARE.
  
 7.2.1.7.2 ONLY APPROVED PANIC HARDWARE SHALL BE USED ON
 DOOR
 ASSEMBLIES THAT ARE NOT FIRE-RATED DOOR ASSEMBLIES.
 ONLY APPROVED FIRE
 EXIT HARDWARE SHALL BE USED ON FIRE-RATED DOOR
 ASSEMBLIES. NEW PANIC
 HARDWARE AND NEW FIRE EXIT HARDWARE SHALL COMPLY WITH
 ANSI/UL
 305, STANDARD FOR SAFETY PANIC HARDWARE, AND ANSI/BHMA
 A156.3, EXIT DEVICES.
  
 3) SHEET 012-C-09, PROVIDE NO PARKING FIRE LANE SIGNAGE
 (SEE PROVISO).
  
 4) SHEET 042-LS-0.4, LEVELS 4-7, EXIT DOORS FROM THIS
 SPACE ARE NOT REMOTE PER SECTION,
 7.5.1.3.3 IN BUILDINGS PROTECTED THROUGHOUT BY AN
 APPROVED,
 SUPERVISED AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE
 WITH SECTION
 9.7, THE MINIMUM SEPARATION DISTANCE BETWEEN TWO EXITS,
 EXIT
 ACCESSES, OR EXIT DISCHARGES, MEASURED IN ACCORDANCE
 WITH 7.5.1.3.2,
 SHALL BE NOT LESS THAN ONE-THIRD THE LENGTH OF THE
 MAXIMUM OVERALL
 DIAGONAL DIMENSION OF THE BUILDING OR AREA TO BE
 SERVED.
  
 5) SHEET 051-A-2.4, EXIT DOORS FROM ASSEMBLY AREAS AND
 OTHER SPACES THAT EXCEED 100 OCCUPANT LOAD ARE NOT
 PROVIDED WITH PANIC HARDWARE. COORDINATE WITH DOOR
 SCHEDULE TO INDICATE CORRECT HARDWARE IS PROVIDED.
 EXAMPLES OF DOORS (412, 413, ST 401, ST 403 AND ST
 406).
  
 12.2.2.2.3 ANY DOOR IN A REQUIRED MEANS OF EGRESS FROM
 AN AREA
 HAVING AN OCCUPANT LOAD OF 100 OR MORE PERSONS SHALL BE
 PERMITTED TO BE PROVIDED WITH A LATCH OR LOCK ONLY IF
 THE LATCH OR
 LOCK IS PANIC HARDWARE OR FIRE EXIT HARDWARE COMPLYING
 WITH
 7.2.1.7, UNLESS OTHERWISE PERMITTED BY ONE OF THE
 FOLLOWING:
  
 6) SHEET 051-A-2.4, EXIT DOOR SHOWN ON PLANS AS ST-405
 SWINGS IN THE WRONG DIRECTION IN ADDITION IT IS NOT
 INCLUDED ON THE DOOR SCHEDULE AND WILL ALSO REQUIRE
 PANIC HARDWARE.
  
 7) SHEET 044-A-2.1, DOORS SHOWN AS DOOR 139, 131 & 132
 APPEAR TO SWING GREATER THAT 50% OF THE REQUIRED EXIT
 WIDTH AND EXCEED MAXIMUM PROJECTION PER SECTION,
 7.2.1.4.3
  
 8) THIS IS FROM A PREVIOUS LIST OF COMMENTS #12 ON
 PREVIOUS LIST.
 SHEET 040-LS-0.2, PROVIDE ONE HOUR RATING TO SEPARATE
 CORRIDOR FROM GARAGE.
 ARROW POINTS TO AREA IN QUESTION.
  
 9) SHEET 092-A-5.2.2, DUPLICATE NOTE. PLEASE REMOVE GAS
 FIREPLACE FROM PLANS.
  
 10) SHEET 317-FS2.7B, AND SHEET 316-FS2.7A, REQUIRED
 FIRE SPRINKLER COVERAGE IS NOT PROVIDED FOR ELEVATOR
 MACHINE ROOMS.
  
 11) SHEET-044-A-2.1, PROVISO NOTE ADDED TO PLANS.
  
 12) GENERAL COMMENT, DO NOT UTILIZE EXIT MARKING
 SIGNAGE AS A METHOD TO DIRECT VEHICLES OUT OF GARAGE.
  
 13) SHEET 241-E2.7A AND SHEET 242-E2.7B, PROVIDE
 REQUIRED EMERGENCY LIGHTING FOR EGRESS FROM ROOF.
  
 14) PER NFPA 241 SECTION 8.7.2.3, WHERE UNDERGROUND
 WATER MAINS AND HYDRANTS ARE TO BE PROVIDED, THEY SHALL
 BE INSTALLED, COMPLETED, AND IN SERVICE PRIOR TO
 CONSTRUCTION WORK.
  
 15) REVIEW AND APPROVAL BY THE AHJ SHALL NOT RELIEVE
 THE OWNER, CONTRACTOR, ETC. OF THE RESPONSIBILITY OF
 COMPLIANCE WITH CODE (NFPA 1, SECTION 1.14.4).
  
 16) EVERY ASSEMBLY OCCUPANCY ROOM NOT HAVING FIXED
 SEATS SHALL HAVE THE OCCUPANT LOAD OF THE ROOM POSTED
 IN A CONSPICUOUS PLACE NEAR THE MAIN EXIT FROM THE
 ROOM. SIGNS SHALL BE DURABLE AND INDICATE THE NUMBER OF
 OCCUPANTS PERMITTED FOR EACH ROOM.
  
 17) FIRE-RATED WALLS
 PER SECTION 8.3.2.4, EACH FIRE BARRIER SHALL BE
 PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING READING
 FIRE BARRIER-PROTECT ALL OPENINGS. CHARACTERS SHALL BE
 AT LEAST 4-INCHES IN HEIGHT AND HALF-INCH IN WIDTH.
 IDENTIFICATION SHALL BE SPACED NOT MORE THAN 15 FEET ON
 CENTER.
 PER SECTION 8.3.5.1, PENETRATIONS THROUGH A FIRE-RATED
 WALL ASSEMBLY SHALL BE PROTECTED BY A FIRE STOP SYSTEM
 OR DEVICE
 .
 18) TACTILE SIGNAGE SHALL BE INSTALLED AT ALL EXIT
 DOORS.
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2016-03-17 Cont ID  
Sent By rlindow Date 2016-03-17 Time   Rev Time 0.00
Received By rlindow Date 2016-03-08 Time   Sent To  
Notes
2016-03-08 13:24:10THE FOLLOWING COMMENTS WERE SUBMITTED BY ROY LINDOW(
 [email protected]), FIRE INSPECTOR, BUREAU OF FIRE
 PREVENTION, WEST PALM BEACH FIRE RESCUE.
  
 THIS REVIEW CAN ONLY BE CONSIDERED PRELIMINARY AS THE
 DRAWINGS THAT WERE REVIEWED WERE NOT COMPLETE.
 ADDITIONAL COMMENTS CAN BE EXPECTED WHEN FULL DRAWINGS
 ARE SUBMITTED FOR PERMIT.
  
 1) -SHEET 043- LS 0.5
 ONE HOUR RATED WALL IS NOT PROVIDED FOR CORRIDOR OF SE
 CORNER OF BUILDING ACROSS FROM STAIR #4.
  
 2) -SHEET 043- LS 0.5
 ADD REQUIRED EXIT SIGNS TO SOUTH AND NORTH CORRIDOR.
 DISTANCE EXCEEDS MAXIMUM OF 100 FT.
  
 3) -SHEET 043- LS 0.5
 ACCOUNT FOR CAPACITY OF EACH EXIT DOOR AND HOW
 OCCUPANCY LOAD IS SPLIT UP.
  
 4) -SHEET 042- LS-0.4
 ADD REQUIRED EXIT SIGNS TO SOUTH AND NORTH CORRIDOR.
 DISTANCE EXCEEDS MAXIMUM OF 100 FT.
  
 5) -SHEET 042- LS-0.4
 EXIT DOORS SWING WRONG DIRECTION FOR ASSEMBLY SPACE AT
 NORTH SIDE OF BUILDING (TERRACE FLOOR 4).
  
 6) -SHEET 042- LS-0.4
 ONE HOUR RATED WALL IS NOT PROVIDED FOR CORRIDOR OF SE
 CORNER OF BUILDING ACROSS FROM STAIR #4.
  
 7) -SHEET 042- LS-0.4
 PROVIDE ONE HOUR RATING TO SEPARATE THE ASSEMBLY
 OCCUPANCY FROM APARTMENT OCCUPANCY.
  
 8) -SHEET 042- LS-0.4
 ACCOUNT FOR CAPACITY OF EACH EXIT DOOR AND HOW
 OCCUPANCY LOAD IS SPLIT UP.
  
 9)-SHEET 041-LS-0.3
 ADD REQUIRED EXIT SIGNS TO SOUTH AND NORTH CORRIDOR.
 DISTANCE EXCEEDS MAXIMUM OF 100 FT.
  
 10)-SHEET 041-LS-0.3
 ACCOUNT FOR CAPACITY OF EACH EXIT DOOR AND HOW
 OCCUPANCY LOAD IS SPLIT UP.
  
 11) -SHEET 040-LS-0.2
 PER SECTION 6.1.14.4.1
 PROVIDE ONE HOUR RATING TO SEPARATE THE ASSEMBLY
 OCCUPANCY FROM APARTMENT OCCUPANCY.
  
 12) -SHEET 040-LS-0.2
 PROVIDE ONE HOUR RATING TO SEPARATE CORRIDOR FROM
 GARAGE.
  
 13) -SHEET 040-LS-0.2
 ADD REQUIRED EXIT SIGNS TO SOUTH CORRIDOR. DISTANCE
 EXCEEDS MAXIMUM OF 100 FT.
  
 14) -SHEET 040-LS-0.2
 ACCOUNT FOR CAPACITY OF EACH EXIT DOOR AND HOW
 OCCUPANCY LOAD IS SPLIT UP.
  
 15) -SHEET 039- LS-0.1
 TWO HOUR ENCLOURE FOR STAIR #2 MISSING DOOR.
  
 16) -SHEET 039- LS-0.1
 ADD REQUIRED EXIT SIGNS TO GARAGE. DISTANCE EXCEEDS
 MAXIMUM OF 100 FT.
  
 17) -SHEET 039- LS-0.1
 ADD REQUIRED EXIT SIGNS TO SOUTH CORRIDOR. DISTANCE
 EXCEEDS MAXIMUM OF 100 FT.
  
 18) -SHEET 039- LS-0.1
 ELECTRIC ROOM, PER NFPA 70, PROVIDE REQUIRED PANIC
 HARDWARE.
  
 19) -SHEET 039- LS-0.1
 ACCOUNT FOR CAPACITY OF EACH EXIT DOOR AND HOW
 OCCUPANCY LOAD IS SPLIT UP.
  
 20) -SHEET 039- LS-0.1
 COMMON PATH OF TRAVEL EXCEEDED IN PARKING GARAGE(100
 FEET).
  
 21) -SHEET 039- LS-0.1
 PLANS SHOW "AREA OF REFUGED#1"? PROVIDE ADDITIONAL
 INFORMATION PERTAINING TO THIS AREA.
  
 22) -SHEET 092-A5.2.2
 GAS FIREPLACE IS NOT PERMITTED.
 PER SECTION 10.11.8.1- INCINERATORS, OUTDOOR
 FIREPLACES, PERMANENT BARBECUES,
 AND GRILLS SHALL NOT BE BUILT, INSTALLED, OR MAINTAINED
 WITHOUT
 PRIOR APPROVAL OF THE AHJ.
  
 23) -SHEET 044-A-2.1
 3' GATE IN THE MEANS OF EGRESS USED FOR ACCESS CONTROL
 REQUIRED TO COMPLY WITH FFPC PER SECTION 7.2.1.6.2
  
 24) -SHEET-090-A-5.1.6
 CONDITION SHOWN ON PLAN.SEPARATE FIRE SUPPRESSION AND
 EXHAUST HOOD PLANS REQUIRED.
  
 25) -SHEET-249-E-4.1
 PLAN SHOWS SMOKE DETECTORS WHERE SMOKE ALARMS ARE
 REQUIRED.
  
 26) -SHEET-012-C-09
 FIRE HYDRANTS ARE TO BE ON THE SAME SIDE OF THE STREET
 AS FIRE DEPARTMENT CONNECTION.
  
 27) -ALL EXISTING AND NEW FIRE HYDRANTS PLANNED FOR
 THIS DEVELOPMENT SHALL BE CLEARLY INDICATED
 AND IDENTIFIED ON THE PLAN AND CLOSELY COORDINATED WITH
 THE BUREAU OF FIRE PREVENTION.
  
 28) -ALL FIRE DEPARTMENT SPRINKLER SYSTEM CONNECTIONS
 (FDC,S) FOR THE PROJECT SHALL BE IDENTIFIED
 AND COORDINATED WITH THE BUREAU OF FIRE PREVENTION.
  
 29) -LIFE SAFETY PLANS AND ELECTRICAL PLANS. SHOW ALL
 EMERGENCY LIGHTING. PLANS NEED TO BE SIMILAR IN
 LOCATION AND IN CONCEPT.
  
 30) - DOOR SCHEDULE DOES NOT INCLUDE ALL RATED DOORS IN
 BUILDING. VERIFY ACCURACY TO INCLUDE ALL RATED DOORS.
  
  
  
 GENERAL COMMENTS NOTED BELOW:
  
 -ALL PARKING STRUCTURES SHALL COMPLY WITH NFPA 88A.
  
 -ALL ELEVATORS SHALL BE EQUIPPED WITH A REGION 7 KEYWAY
 SYSTEM.
  
 -CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY
 WITH NFPA 241. EXTRA ATTENTION SHALL BE GIVEN TO THE
 PERMITTING AND LOCATION OF CONSTRUCTION TRAILERS.
 A PERMIT IS REQUIRED FOR ANY CONSTRUCTION TRAILER
 RELATED TO THIS PROJECT. SEPARATION DISTANCES FROM MAIN
 STRUCTURES AS WELL AS OTHER TRAILERS SHALL BE CLOSELY
 MONITORED FOR THE REQUIREMENTS OF FIRE SPRINKLER
 PROTECTION.
  
 -SITE ACCESS AND EXIT POINTS ARE TO BE CLEARLY
 IDENTIFIED AND MAINTAINED FOR EMERGENCY VEHICLES DURING
 ALL CONSTRUCTION ACTIVITIES.
  
 -THE BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM ALL
 ACCESS ROADWAYS, INCLUDING DURING CONSTRUCTION. ADDRESS
 NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND
 AND SHALL NOT BE LESS THAN SIX (6) INCHES IN HEIGHT
 WITH A ONE (1) INCH STROKE FOR ALL BUILDINGS.
  
 -DURING CONSTRUCTION, TRASH AND DEBRIS IS TO BE REMOVED
 FROM THE SITE DAILY OR MORE OFTEN TO REDUCE THE
 ACCUMULATION OF POTENTIAL LIFE AND FIRE SAFETY HAZARDS.
  
 -ALL STAIRWELL ENCLOSURES.
 PER SECTION 7.2.2.5.4 - STAIRWAY IDENTIFICATION: NEW
 ENCLOSED STAIRS SERVING THREE OR MORE STORIES AND
 EXISTING ENCLOSED STAIRS SERVING FIVE OR MORE STORIES
 SHALL COMPLY WITH (A) THROUGH (L).
 (A) THE STAIRS SHALL BE PROVIDED WITH SPECIAL SIGNAGE
 WITHIN THE ENCLOSURE AT EACH FLOOR LANDING.
 (B) THE SIGNAGE SHALL INDICATE THE FLOOR LEVEL.
 (C) THE SIGNAGE SHALL INDICATE THE TERMINUS OF THE TOP
 AND BOTTOM OF THE STAIR ENCLOSURE.
 (D) THE SIGNAGE SHALL INDICATE THE IDENTIFICATION OF
 THE STAIR ENCLOSURE.
 (E) THE SIGNAGE SHALL INDICATE THE FLOOR LEVEL OF, AND
 THE DIRECTION TO, EXIT DISCHARGE.
 (F) THE SIGNAGE SHALL BE LOCATED INSIDE THE ENCLOSURE
 APPROXIMATELY 60-INCHES ABOVE THE FLOOR LANDING IN A
 POSITION THAT IS VISIBLE WHEN THE DOOR IS IN THE OPEN
 OR CLOSED POSITION.
 (G) THE FLOOR LEVEL DESIGNATION SHALL ALSO BE TACTILE.
 (H) THE SIGNAGE SHALL BE PAINTED OR STENCILED ON THE
 WALL OR ON A SEPARATE SIGN SECURELY ATTACHED TO THE
 WALL.
 (I) THE STAIRWAY IDENTIFICATION LETTER SHALL BE LOCATED
 AT THE TOP OF THE SIGN IN MINIMUM 1-INCH HIGH
 LETTERING.
 (J) SIGNAGE THAT READS ?NO ROOF ACCESS? AND IS LOCATED
 UNDER THE STAIRWAY IDENTIFICATION LETTER SHALL
 DESIGNATE STAIRWAYS THAT DO NOT PROVIDE ROOF ACCESS.
 LETTERING SHALL BE A MINIMUM OF 1-INCH HIGH.
 (K) THE FLOOR LEVEL NUMBER SHALL BE LOCATED IN THE
 MIDDLE OF THE SIGN IN MINIMUM 5-INCH HIGH NUMBERS.
 MEZZANINE LEVELS SHALL HAVE THE LETTER ?M? OR OTHER
 APPROPRIATE IDENTIFICATION LETTER PRECEDING THE FLOOR
 NUMBER, WHILE BASEMENT LEVELS SHALL HAVE THE LETTER ?B?
 OR OTHER APPROPRIATE IDENTIFICATION LETTER PRECEDING
 THE FLOOR LEVEL NUMBER.
 (L) IDENTIFICATION OF THE LOWER AND UPPER TERMINUS OF
 THE STAIRWAY SHALL BE LOCATED AT THE BOTTOM OF THE SIGN
 IN MINIMUM 1-INCH HIGH LETTERS OR NUMBERS.
  
 -FOR ASSEMBLY AND EDUCATIONAL OCCUPANCIES WITH AN
 OCCUPANT LOAD OF 100 OR MORE PERSONS (50 PERSONS PER
 THE FLORIDA BUILDING CODE), PANIC HARDWARE SHALL BE
 PROVIDED ON DOORS TO RELEASE THE LOCK/LATCH. NO OTHER
 LOCKS OR LATCHES ARE PERMITTED THAT WOULD NOT BE
 RELEASED BY THE PANIC HARDWARE. AS A SUBSTITUTE FOR
 PANIC HARDWARE, THE MAIN ENTRANCE IS PERMITTED TO HAVE
 AN INTERIOR KEYED DOOR LOCK (AND NO LATCH) WITH A
 READILY VISIBLE SIGN STATING THIS DOOR TO REMAIN
 UNLOCKED WHEN THE BUILDING IS OCCUPIED. SIGN LETTERS
 SHALL BE AT LEAST 1 INCH IN HEIGHT. A THUMB TURN STYLE
 LOCK IS NOT PERMITTED TO BE SUBSTITUTED FOR A KEYED
 LOCK.
  
 -PROVIDE DRAWING NOTE INDICATING ALL CONSTRUCTION AND
 DEMOLITION WORK SHALL CONFORM TO THE REQUIREMENTS OF
 NFPA 241. TRASH AND CONSTRUCTION DEBRIS SHALL BE
 REMOVED FROM THE SITE DAILY. SMOKING SHALL BE
 PROHIBITED EXCEPT IN DESIGNATED EXTERIOR AREAS. ALL
 OTHER DEMOLITION OR CONSTRUCTION AREAS SHALL HAVE "NO
 SMOKING" SIGNS POSTED. WHERE SMOKING IS PERMITTED, SAFE
 RECEPTACLES FOR SMOKING MATERIALS SHALL BE PROVIDED.
  
 -SEPARATE PLANS AND PERMITS NEEDED FOR PRIVATE
 UNDERGROUND FIRE LINE AND FIRE HYDRANTS.
  
 -PROVIDE AN EXTERIOR KEY SAFE TO ALLOW EMERGENCY
 RESPONDERS NON-FORCIBLE ENTRY INTO THE BUILDING DURING
 NON-BUSINESS HOURS. A KEY SAFE CAN BE ORDERED FROM
 WWW.KNOXBOX.COM.
  
 -PROVIDE A KNOX KEY SWITCH TO ALLOW GATE ACCESS TO
 EMERGENCY RESPONDERS. KEY SWITCH CAN BE ORDERED FROM
 WWW.KNOXBOX.COM.
  
 -PER SECTION 10.12.1.2 (NFPA 1), PROVIDE BUILDING
 ADDRESS VISIBLE FROM THE STREET. NUMBERS SHALL BE
 ATTACHED TO THE BUILDING AND BE AT LEAST SIX-INCHES IN
 HEIGHT WITH 1-INCH STROKE AND SHALL CONTRAST THE
 BACKGROUND.
  
 -PER SECTION 8.3.2.4
 EACH NEW FIRE WALL, FIRE BARRIER, FIRE PARTITION, SMOKE
 BARRIER, SMOKE PARTITION, OR ANY OTHER NEW WALL
 REQUIRED TO HAVE
 PROTECTED OPENINGS SHALL BE PERMANENTLY IDENTIFIED WITH
 SIGNS OR
 STENCILING ABOVE ANY DECORATIVE CEILING AND IN
 CONCEALED SPACES
 WITH THE WORDING, "FIRE AND SMOKE BARRIER PROTECT
 ALL OPENINGS" OR SIMILAR LANGUAGE. SUCH SIGNS OR
 STENCILING
 SHALL BE IN 4 INCH HIGH LETTERS, ? INCH STROKE, AND NOT
 MORE THAN 15
 FEET ON-CENTER.
  
  
  

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2016-10-21 Cont ID  
Sent By gjohnson Date 2016-10-21 Time 12:59 Rev Time 0.00
Received By gjohnson Date 2016-10-21 Time 12:59 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2016-09-12 Cont ID  
Sent By gjohnson Date 2016-09-12 Time 14:07 Rev Time 0.00
Received By gjohnson Date 2016-09-12 Time 14:07 Sent To  
Notes
2016-09-12 15:23:372ND REVIEW: FBC 2014
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  
 GAS COMMENTS: 2ND REQUEST
  
 1. CLEARLY SHOW ALL CUT SECTIONS OF PIPE AND
 CORRESPONDING LENGTHS PER FBC-2014 FUEL GAS, SECS.
 402.4.1, 402.4.2.
  
 2. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED ON
 RISER , ALL PIPE SIZES, AND THE EHD NUMBER OF
 CORRUGATED STAINLESS STEEL TUBING FOR EACH PIPE SIZE IF
 BEING USED. WPB AMENDMENTS TO FBC SEC. 107.2.1.
  
 3. SHOW PIPE SIZE DOWN STEAM OF REGULATORS. WPB
 AMENDMENTS TO FBC SEC. 107.2.1.
  
 4. SUBMIT CALCULATIONS FOR COMBUSTION AIR ON RANGE PER
 THE FBC-2014 FUEL GAS CODE SEC. 304.
  
 5. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL
 GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA
 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2
  
 6. PLEASE CLARIFY SYSTEM PRESSURE IT APPEARS TO BE A
 2LB SYSTEM BEING REDUCED DOWN TO .5LB AT EACH APPLIANCE
 BY REGULATORS. THE TABLES YOU REFERENCE INDICATE .5LB
 PLEASE INDICATE ON THE RISER THE PRESSURE IN EACH
 SECTION OF THE SYSTEM. PER WPB AMEND TO FBC 107.2.1
  
 7. PROVIDE EMERGENCY SHUT OF VALVE ON GAS SUPPLY TO
 RANGE
  
 DO TO PLANS BEING INCOMPLETE OR UNCLEAR, A
 COMPREHENSIVE PLAN REVIEW CANNOT BE DONE AT THIS TIME,
 THERE MAYBE ADDITIONAL COMMENTS ON RESUBMITTAL OF
 PLANS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE
 PREVIOUSLY REVIEWED SHEETS.
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2016-06-16 Cont ID  
Sent By gjohnson Date 2016-06-16 Time 08:24 Rev Time 0.00
Received By gjohnson Date 2016-06-16 Time 08:24 Sent To  
Notes
2016-06-16 08:39:031ST REVIEW: FBC 2014
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  
 GAS COMMENTS:
  
 1. CLEARLY SHOW ALL CUT SECTIONS OF PIPE AND
 CORRESPONDING LENGTHS PER FBC-2014 FUEL GAS, SECS.
 402.4.1, 402.4.2.
  
 2. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL
 PIPE SIZES, AND THE EHD NUMBER OF CORRUGATED STAINLESS
 STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. WPB
 AMENDMENTS TO FBC SEC. 107.2.1.
  
 3. SHOW PIPE SIZE DOWN STEAM OF REGULATORS. WPB
 AMENDMENTS TO FBC SEC. 107.2.1.
  
 4. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE
 FBC-2014 FUEL GAS CODE SEC. 304.
  
 5. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL
 GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA
 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2
  
  
  
 DO TO PLANS BEING INCOMPLETE OR UNCLEAR, A
 COMPREHENSIVE PLAN REVIEW CANNOT BE DONE AT THIS TIME,
 THERE MAYBE ADDITIONAL COMMENTS ON RESUBMITTAL OF
 PLANS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE
 PREVIOUSLY REVIEWED SHEETS.
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2016-10-28 Cont ID  
Sent By cpuell Date 2016-10-28 Time 11:18 Rev Time 0.00
Received By cpuell Date 2016-10-18 Time 11:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-09-28 Cont ID  
Sent By shill Date 2016-09-16 Time 10:15 Rev Time 0.00
Received By shill Date 2016-08-10 Time 10:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-08-01 Cont ID  
Sent By lmarchan Date 2016-08-01 Time 16:10 Rev Time 0.00
Received By lmarchan Date 2016-05-25 Time 13:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-04-11 Cont ID  
Sent By cpuell Date 2016-04-11 Time 08:40 Rev Time 0.00
Received By cpuell Date 2016-02-08 Time 08:16 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status P Date 2016-10-25 Cont ID  
Sent By shill Date 2016-10-25 Time 14:50 Rev Time 0.00
Received By shill Date 2016-10-25 Time 14:50 Sent To  
Notes
2016-10-25 14:51:07ROUTED STAMPED PLAN TO RECORDS
  
 MU-2016-023753-0000
 MU-2016-24011-0000
 MU-2016-024046-0000
  
2016-10-25 12:42:44GIVEN TO SHILL

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2016-10-25 Cont ID  
Sent By shill Date 2016-10-25 Time 08:01 Rev Time 0.00
Received By shill Date 2016-10-21 Time 14:30 Sent To  
Notes
2016-10-21 14:35:11****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 PROVIDE THE PLAN STAMPED BY THE COUNTY
 THIS MAY BE SUBMITTED AT ANY TIME (DO NOT NEED TO WAIT
 FOR THE REVIEW CYCLE TO BE COMPLETE)
  
 MU-2016-023753-0000
 MU-2016-24011-0000
 MU-2016-024046-0000
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2016-06-07 Cont ID  
Sent By shill Date 2016-06-07 Time 07:36 Rev Time 0.00
Received By shill Date 2016-06-07 Time 07:36 Sent To  
Notes
2016-06-07 07:36:37****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED
 PRIOR TO PERMIT ISSUANCE. THE PLANS ARE TO BE STAMPED
 AND THE RECEIPT SHOWING THAT FEES WERE PAID IS TO BE
 PROVIDED. THIS MAY BE DONE AT ANY POINT DURING THE PLAN
 REVIEW PROCESS.
  
 FOR MORE INFORMATION, CONTACT 561-233-5025.
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2016-03-01 Cont ID  
Sent By shill Date 2016-03-01 Time 17:14 Rev Time 0.00
Received By shill Date 2016-03-01 Time 17:14 Sent To  
Notes
2016-03-01 17:16:27****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED
 PRIOR TO PERMIT ISSUANCE. THE PLANS ARE TO BE STAMPED
 AND THE RECEIPT SHOWING THAT FEES WERE PAID IS TO BE
 PROVIDED. THIS MAY BE DONE AT ANY POINT DURING THE PLAN
 REVIEW PROCESS.
  
 FOR MORE INFORMATION, CONTACT 561-233-5025.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2016-10-27 Cont ID  
Sent By ccole Date 2016-10-27 Time 15:16 Rev Time 0.00
Received By ccole Date 2016-10-26 Time 18:02 Sent To  
Notes
2016-10-27 15:31:27MECHANICAL PROVISOS
 10/27/16
  
 1) THE UPLOADED ENGINEERING DOCUMENTS FOR ANCHORING THE
 CARRIER, MITSUBISHI, AND FIRST COMPANY EXTERIOR UNITS
 MUST BEAR THE ORIGINAL SIGNATURES AND SEALS OF THE
 ENGINEERS WHO PREPARED THE DOCUMENTS.
  
 2) PROVIDE AHRI CERTIFICATES FOR THE THORUGH THE WALL
 APARTMENT AC SYSTEMS.
  
 3) SEPARATE PERMITS AND PLANS ARE REQUIRED FOR THE
 KITCHEN HOOD AND FIRE SUPPRESSION SYSTEM IN THE
 CLUBHOUSE.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2016-08-26 Cont ID  
Sent By ccole Date 2016-08-26 Time 08:34 Rev Time 0.00
Received By ccole Date 2016-08-25 Time 09:24 Sent To  
Notes
2016-08-26 09:57:253RD REVIEW FBC-2014 MECHANICAL
 PERMIT #16020194
 8/26/16
  
 1) THE REVISED AC COOLING AND HEATING CALCULATIONS ARE
 MISSING THE A1, A1 COR, A2, AND A3 SYSTEMS.
  
 2) THE ENERGY/GAUGE COMPLIANCE SUBMITTAL IS MISSING THE
 DATA FOR THE MITSUBISHI SYSTEMS.
  
 3) COMMENT #1 FROM THE PREVIOUS REVIEW HAS NOT
 COMPLETELY ADDRESSED. A) PROVIDE A REVISED FAN SCHEDULE
 ON SHEET M-5.2 THAT SHOWS THE NEW, LARGER CAPACITY
 GARAGE EXHAUST FANS. B) SHEETS M-2.1A & M-2.2A: THE
 6000 EXHAUST CFM'S SHOWN AT THE SOUTH SIDE OF THE
 GARAGE FOR LEVELS 1 & 2 DO NOT MATCH WITH THE EXHAUST
 CFMS SHOWN ON THE RISER DRAWING ON SHEET M-6.2.
  
 4) COMMENT #15 FROM THE PREVIOUS REVIEW HAS NOT BEEN
 COMPLETELY ADDRESSED. A) DEMAND CONTROLLED VENTILATION
 IS REQUIRED FOR THE THEATRE- PLEASE PLACE A NOTE ON THE
 PLAN AND SHOW THE LOCATIONS OF CO2 SENSORS. B) SUBMIT
 MANUFACTURER'S SPECIFICATIONS FOR THE SENSORS REVIEWED
 WITH SIGNATURE BY THE EOR. THE SPECS SHALL PROVIDE
 INSTRUCTIONS FOR INSTALLATION OF THE SENSORS
  
 INCLUDING PLACEMENT AND SPACING OF THE DEVICES.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2016-06-09 Cont ID  
Sent By ccole Date 2016-06-09 Time 07:58 Rev Time 0.00
Received By ccole Date 2016-06-07 Time 15:23 Sent To  
Notes
2016-06-09 08:39:502ND REVIEW: FBC 2014 MECHANICAL, ENERGY CONSERVATION
 PERMIT #16020194
 6/9/16
  
 1) REFER TO SECTION 404.2: THE TOTAL 153900 SQUARE
 FOOTAGE OF THE GARAGE LEVELS 1-7 WILL REQUIRE AN
 EXHAUST VENTILATION SYSTEM CAPABLE OF PRODUCING A
 MAXIMUM VENTILATION AIR FLOW RATE OF 115,470 CFMS AT
 .75 CFMS PER SF. GEF-3 WHICH HAS A MAX RATE OF 20,000
 CFMS IS ADEQUATELY SIZED FOR THE 2ND LEVEL GARAGE IT IS
 SERVICING, HOWEVER THE ROOF-MOUNTED GEF-1 & 2 DO NOT
 HAVE THE CAPACITIES TO SERVICE THE REMAINING LEVELS.
  
 2) REFER TO SECTION 501.4 AND CLARIFY HOW MAKEUP AIR
 FOR THE GARAGE EXHAUST SYSTEMS IS BEING PROVIDED: THE
 CONTROL DIAGRAM ON M-6.3 DEPICTS NORTH AND SOUTH
 OUTSIDE AIR SHAFTS AND SPECIFES SUPPLY FANS IN THE
 SEQUENCE NOTES, HOWEVER THESE SHAFTS AND SUPPLY FANS DO
 NOT APPEAR TO BE SHOWN ON THE GARAGE MECHANICAL PLANS.
  
 3) SHEETS M-6.3 AND M-2.1A & M-2.2A: THE CONTROLS
 DIAGRAM SHOWS THE AMS AT BOTH NORTH AND SOUTH LOCATIONS
 FOR GARAGE LEVELS 1 & 2, HOWEVER THEY ARE NOT SHOWN ON
 THE MECHANICAL PLANS FOR THE THOSE LEVELS.
  
 4) REFERENCE WAS MADE TO SECTION C403.2.9 FBC-14 ENERGY
 CONSERVATION (COMMENT #18) WHICH REQUIRES COMMISSIONING
 OF THE MECHANICAL SYSTEMS ON THE PROPOSED PROJECT.
 PLEASE REVIEW SECTION C408 AND SUBMIT A COMMISSIONING
 PLAN IN ACCORDANCE WITH SECTION C408.2.1.
  
 5) THE SUBMITTED AC COOLING AND HEATING SUMMARY
 CALCULATIONS FROM DTM TECH INC. MUST BE SIGNED AND
 SEALED BY THE ENGINEER OF RECORD- SECTION C403.2.1.
  
 6) SHEET M3.1A: THE REDCIRCULATION OF AIR FROM THE DOG
 PARLOR IS PROHIBITED PER TABLE 403.3 FOOTNOTE B. PLEASE
 REMOVE THE TRANSFER DUCT.
  
 7) M3.1A: THE SUPPLY AIR STREAM IN THE ZOOM LOCKER ROOM
 SHALL NOT CONTAIN MORE THAN 10% OF REIRCULATED AIR FROM
 THE SPACE. IT APPEARS THAT THE 48X6 RETURN AIR GRILL
 WILL ALLOW RECIRCULATION EXCEEDING THE ALLOWABLE LIMIT.
 PLEASE PROVIDE A CALCULATION TO VERIFY COMPLIANCE.
  
 8) AS PREVIOUSLY REQUESTED, AND IN ACCORDANCE WITH
 ASHRAE 62.1 AND TABLE 403.3, PROVIDE VENTILATION FOR
 THE TELECOM AND STORAGE ROOMS.
  
 9) AS PREVIOUSLY REQUESTED, AND IN ACCORDANCE WITH
 ASHRAE 62.1 AND TABLE 403.3, PROVIDE EXHAUST SYSTEMS
 FOR THE TRASH ROOMS.
  
 10) M-2.2C: REFER TO SECTION 501.3.1(2) AND INDICATE
 ALL REQUIRED CLEARANCE DISTANCES FOR THE TWO EXHAUST
 OUTLETS ON THE NORTH SIDE OF THE BUILDING. AS
 PREVIOUISLY NOTED, FL. PRODUCT APPROVALS AND/OR
 MIAMI-DADE NOA'S MUST BE SUBMITTED FOR THE EXHAUST
 OUTLET LOUVERS WITH APPROVAL SIGNATURE BY THE EOR. THE
 LOUVERS SHALL ALSO COMPLY WITH AMCA STANDARD 550.
  
 11) M-3.1A, 3.1B: REFER TO COMMENT #10 ABOVE AND SHOW
 COMPLIANCE FOR ALL EXHAUST OUTLETS ON THE WEST SIDE,
 AND ALSO SEE SECTION 401.4 AND PROVIDE CLEARANCE
 DISTANCE MEASUREMENTS FOR THE OUTDOOR AIR INLETS FOR
 AC-4, 4A, 5, 6, 7, & 8.
  
 12) M3.2C: PER THE NARRATIVE RESPONSE, THE LOCATION OF
 CU-8 IS SHOWN ON THIS PLAN, HOWEVER THIS PLAN SHEET IS
 NOT IN THE UPLOADED PLAN SETS ON THE INDEX.
  
 13) M-2.7A & 7B: AS PREVIOUSLY REQUESTED PROVIDE SIZING
 CALCULATIONS FOR THE ELEVATOR HOISTWAY VENTS IN
 COMPLIANCE WITH SECTION 3004.3 FBC-14 BUILDING.
  
 14) M-3.1B: IT APPEARS THAT NON-METALLIC FLEXIBLE DUCTS
 ARE BEING USED FOR EXHAUST IN THE POOL BATHROOMS PLEASE
 PROVIDE A MANUFACTURER'S SPECIFICATION SHEET INDICATING
 THE DUCTS CAN BE USED FOR THIS PURPOSE.
  
 15) M-3.1C: PLEASE INDICATE HOW DEMAND CONTROLLED
 VENTILATION IS BEING CONTROLLED AND SHOW THE LOCATION
 OF THE C02 SENSORS.
  
 16) M-7.2: AS PREVIOUSLY NOTED IN THE 1ST REVIEW, NOA
 #07-0509.09 FOR THE ROOF STAND IS EXPIRED. PLEASE
 PROVIDE THE CORRECT NOA # ON THE PLAN, AND THE WIND
 LOAD DESIGN CRITERIA FOR ALL EXTERIOR INSTALLATIONS
 SHOWN ON THE PLAN.
  
 17) PLEASE PROVIDE AN AIR DEVICE SCHEDULE INDICATING
 MAKES, MODELS, AND DIMENSIONS OF ALL SUPPLY DIFFUSERS
 AND RETURN GRILLS, AND ACCESSORIES.
  
 18) PROVIDE CONDENSATE DISPOSAL PLANS AND DETAILS FOR
 ALL AC SYSTEMS SHOWN ON THE PLANS. IF LOCATED IN THE
 PLUMBING DRAWINGS AND RISER DIAGRAMS, PLEASE INDICATE
 ON WHICH PLAN SHEETS.
  
 19) M-4.1, 4.2, & 4.3: SUBMIT MANUFACTURER'S
 SPECIFICATIONS FOR THE DRYERS AND KITCHEN EXHAUST
 HOODS. THE DRYER EXHAUST DUCT RUNS FOR ALL UNITS EXCEED
 THE ALLOWABLE 35' MAXIMUM ALLOWABLE BY SECTION
 504.6.4.1, PLEASE NOTE THE DUCT RUN CHART ON SHEET
 M-4.3 DOES NOT INDICATE THE MANUFACTURER.
  
 20) M-4.1, 4.2, & 4.3: THE O/A INTAKES ON MANY OF THE
 UNITS APPEAR TO BE LOCATED IN PROXIMITY OF THE
 CONDENSER EXHAUST GRILLS. REFER TO SECTION 401.4 AND
 ADD CLEARANCE MEASUREMENTS TO VERIFY COMPLIANCE.
  
 21) M-4.2: THE BEDROOM RETURN TRANSFER FOR ALL UNITS ON
 THIS SHEET APPEAR TO BE POINTING IN THE WRONG
 DIRECTION- PLEASE CORRECT.
  
 22) EACH UPLOADED WIND LOAD ENGINEERING DOCUMENT FOR
 THE CARRIER, MITSUBISHI, FIRST COMPANY UNITS, AND THE
 ROOF STANDS AND WALL BRACKETS HAVE SCANNED ENGINEER'S
 SEALS- EACH MUST BE DIGITALLY SIGNED AND SEALED BY THE
 ENGINEER WHO PREPARED THEM. THE DOCUMENTS MUST ALSO BE
 APPROVAL WITH SIGNATURE BY THE PROJECT ENGINEER OF
 RECORD.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-02-24 Cont ID  
Sent By ccole Date 2016-02-24 Time 16:51 Rev Time 0.00
Received By ccole Date 2016-02-23 Time 12:20 Sent To  
Notes
2016-02-24 16:51:431ST REVIEW: FBC 2014 MECHANICAL
 PERMIT #16020194
 2/23/16
  
 1) DISCREPANCIES BETWEEN THE FIFTH EDITION 2014 ENERGY
 EFFICIENCY COMPLIANCE FORM SUBMITTAL AND THE AC PLANS
 AND EQUIPMENT SCHEDULES:
 A) COMPLIANCE FORM LISTS RTU'S 1-5 AT 338,000 BTUH
 COOLING EACH AT 11.30 EER EACH,
 -THE AC SCHEDULE INDICATES 322,130 BTUH COOLING AT 12.8
 EER.
 B) FORM LISTS THE FITNESS CENTER SPLIT SYSTEM AT
 150,000 BTUH COOLING AT 12 EER,
 - THE SCHEDULE INDICATES 120,000 BTUH COOLING AT 11.2
 EER
 C) FORM LISTS THE OFFICE 136 AND 137 SPLIT SYSTEMS AT
 42,000 BTUH COOLING AT 14 SEER,
 - THE SCHEDULE INDICATES TOTAL COOLING CAPACITY FOR
 EACH AT 30,000 BTUH AT 14 SEER.
 D) FORM LISTS THE THEATER SPLIT SYSTEM AT 23,000 BTUH
 COOLING AT 16 SEER,
 - THE SCHEDULE INDICATES 24,000 BTUH COOLING AT 16.5
 SEER.
 E) TWO LEASING CENTER SPLIT SYSTEMS ARE INDICATED ON
 THE SCHEDULE WITH CAPACITIES AND EFFICIENCY RATINGS
 THAT DON'T MATCH THE SINGLE LEASING CENTER SYSTEM
 LISTED ON THE COMPLIANCE FORM.
 F) FORM LISTS AHU-5 AT 46,000/14 SEER, THE SCHEDULE
 LISTS 30,000/14.
 G) FORM LISTS RES LOBBY-N & S AT 12,000/14 SEER,
 SCHEDULE LISTS 9,000/14.5 SEER.
 H) FORM LISTS THE CLUBHOUSE FITNESS AT 90,000/12 EER,
 THE SCHEDULE ON SHEET M-5.3 LISTS THRE FITNESS ROOM AT
 2.5TON/15 SEER.
 I) FORM LISTS ST1 & ST2 SYSTEMS AT 12,000/14 SEER, THE
 SCHEDULE LISTS RESIDENTIAL AC-1.2 AT 15,000/14 SEER.
 J) THERE IS NO COMPLIANCE DATA LISTED ON THE ENERGY
 FORM FOR RTU'S A & B SHOWN IN THE SCHEDULE ON M-5.3,
 AND FOR THE DUCTLESS SYSTEMS AC-1- AC-13 SHOWN ON SHEET
 M-5.1.
  
 2) THE AC IDENTIFICATION LABELS FOR THE RESIDENTIAL
 UNITS USED IN THE ENERGY AND AC COOLING AND HEATING
 LOAD SUMMARIES SUBMITTALS DO NOT DIRECTLY CORRELATE
 WITH THE LABELING SHOWN IN THE SCHEDULE ON SHEET M-5.1.
 THE LOAD SUMMARIES ARE ALSO INDICATING EACH SYSTEM AS A
 SINGLE ZONE HOWEVER EACH OF THESE SYSTEMS ARE SHOWN ON
 THE PLANS TO BE LOCATED IN MULTIPLE DIRECTIONAL
 ORIENTATIONS- PLEASE REFER TO SECTIONS C407.4.2-
 C407.5.2.3 FBC-14 ENERGY CONSERVATION-
 MULTIFAMILY RESIDENTIAL BUILDINGS.
 RESIDENTIAL SPACES SHALL BE MODELED USING ONE THERMAL
 BLOCK PER SPACE EXCEPT THAT THOSE FACING THE SAME
 ORIENTATIONS ARE PERMITTED TO BE COMBINED INTO ONE
 THERMAL BLOCK. CORNER UNITS AND UNITS WITH ROOF OR
 FLOOR LOADS SHALL ONLY BE COMBINED WITH UNITS SHARING
 THESE FEATURES.
 AS STATED IN THE ABOVE CODE SECTIONS CALCULATIONS SHALL
 BE DONE USING THERMAL BLOCKS AND ZONES. REVISE THE
 CALCULATIONS ACCORDINGLY AND PROVIDE A THERMAL ZONE
 DIAGRAM AND SCHEDULE TO ACCOMPANY THE CALCULATIONS. THE
 SCHEDULE SHALL CLEARLY INDICATE WHICH SYSTEMS ARE IN
 WHICH BLOCK OR ZONE, AND THE DIRECTIONAL ORIENTATIONS.
 A) PLEASE NOTE THAT AC CALCULATIONS HAVE NOT BEEN
 SUBMITTED FOR THE DUCTLESS SYSTEMS.
 B) THE CALCULATIONS FOR THE FITNESS ROOM INDICATE 127.9
 MBH OR 10.7 TONS, HOWEVER THE SCHEDULE IS INDICATING
 2.5 TONS FOR FITNESS ROOM RTU-A ON SHEET M-5.3.
 C) THE SUBMITTED AC SYSTEM SIZING SUMMARY SHEETS MUST
 BE SIGNED AND SEALED BY A LICENSED DESIGN PROFESSIONAL
 PER SECTION C403.2.1 FBC-14 ENERGY CONSERVATION.
  
 3) SHEET M-5.3, OUTSIDE AIR CALCULATIONS: PROVIDE
 CALCULATIONS FOR THE RESIDENTIAL UNITS, THE CORRIDORS,
 THE BRIDGE AREA, THE WORK ROOMS, AND THE DOG PARLOR PER
 TABLE 403.3 FBC-14 MECHANICAL.
 4) PROVIDE EXHAUST VENTILATION CALCULATIONS FOR THE
 TRASH ROOMS, RESIDENTIAL BATHROOMS, POOL BATHROOMS,
 POOL EQUIPMENT ROOMS, MAINTENANCE ROOMS, ELECTRICAL
 ROOMS, STORAGE ROOMS, PUMP ROOMS, DOG PARLOR, OFFICE
 136 & 137 & OFFICE AREA TOILET ROOMS, SERVICE COURT,
 AND THE FITNESS CLUB ROOM.
 5) PROVIDE AIR BALANCE CALCULATIONS.
 6) PROVIDE EXHAUST VENTILATION CALCULATIONS FOR EACH
 LEVEL OF THE GARAGE- REFER TO SECTION 404.2 FBC-14
 MECHANICAL. PLEASE NOTE THAT THE GROUND AND SECOND
 LEVEL PLANS M-2.1A AND M-2.1A APPEAR TO INDICATE A
 SUPPLY AIR FAN "GE-1A" HOWEVER I AM NOT SEEING ANY DATA
 FOR THE FANS IN THE SCHEDULES, NOR ARE THESE FANS SHOWN
 ON THE 3RD- 8TH LEVELS.
 7) GARAGE- ALL LEVELS: INDICATE HOW ALL THE FANS, AC
 CONDENSERS, AND OTHER MECHANICAL EQUIPMENT AND
 COMPONENTS WILL BE PROTECTED FROM VEHICLE DAMAGE-
 SECTION 303.4 FBC-14 MECHANICAL
 8) SHEETS M-2.1A- M-2.6B: VENTILATION NOT SHOWN FOR THE
 ELECTRICAL ROOMS, THE TELECOM ROOMS, AND THE STORAGE
 ROOMS ON ANY OF THE MECHANICAL FLOOR PLANS FROM THE
 GROUND LEVEL TO LEVEL 8. HOW WILL THESE ROOMS BE
 VENTILATED.
 8) SHEET M-2.1A: IT APPEARS THAT THE AMS IS MISSING FOR
 THE GARAGE EXHAUST FAN AT THE NORTH END OF THE GARAGE.
 9) SHEET M-2.1A: LABEL THE AC UNIT IN THE TRASH ROOM
 AND PROVIDE AN EXHAUST VENTILATION SYSTEM- TABLE 6-4
 ASHRAE 62.1-2010.
 10) M-2.1A: PROVIDE AN EXHAUST VENTILATION SYSTEM FOR
 THE ZOOM LOCKERS ROOM- TABLE 6-4 ASHRAE 62.1-2010.
 11) M-2.1A: INDICATE THE HEIGHT FROM THE GARAGE FLOOR
 TO THE BOTTOM OF THE RF-1 FAN ON ALL GARAGE FLOOR
 LEVELS- SECTION 304.6 FBC-14 MECHANICAL.
 12) M-2.1C: THE NOTE IN THE SERVICE COURT REFERENCES
 SHEET M2.2 WHICH IS NOT INCLUDED WITH THE PLAN SETS.
 14) M-2.2A: IT APPEARS THAT THE AMS IS MISSING FOR THE
 EXHAUST FAN AT THE NORTH END OF THE GARAGE.
 15) M-2.2C: REFER TO SECTION 501.3.1 FBC-14 MECHANICAL
 AND PROVIDE CLEARANCES FOR THE EXHAUST TERMINATIONS ON
 THE NORTH SIDE. PLEASE NOTE THAT A FLORIDA PRODUCT
 APPROVAL OR MIAMI-DADE NOA FOR THE EXHAUST LOUVER MUST
 BE SUBMITTED WITH A REVIEW AND APPROVAL SIGNATURE BY
 THE DESIGN PROFESSIONAL OF RECORD. A) INDICATE THE
 REQUIRED CLEARANCES FOR THE GARAGE AIR INTAKE ON THE
 NORTH SIDE AS REQUIRED BY SECTION 401.4. B) AS
 PREVIOUSLY NOTED, THE "GE-1A" TAG BY THE GARAGE INTAKE
 GRILL APPEARS TO BE INDICATING A FAN, HOWEVER I AM NOT
 SEEING THE FAN IN ANY OF THE HVAC SCHEDULES: PLEASE
 CLARIFY.
 16) M-2.2C: THERE IS A NOTE BY THE NORTH TELECOM ROOM
 REFERENCING SHEET M3.1 WHICH IS NOT INCLUDED WITH THE
 PLAN SETS.
 17) M-2.4B: INDICATE HOW THE BRIDGE WILL BE VENTILATED
 18) REFER TO SECTION C403.2.9 FBC ENERGY CONSERVATION
 AND VERIFY COMPLIANCE FOR ALL EXHAUST AND SUPPLY FANS
 TO BE USED ON THE PROJECT.
  
 19) M-2.6A: IT APPEARS THAT THE AMS EQUIPMENT IS
 MISSING FOR THE GARAGE EXHAUST FANS AT THE NORTH AND
 SOUTH ENDS.
 20) M-2.7A & 7B: SITE SPECIFIC WIND LOAD ENGINEERING IS
 REQUIRED FOR ANCHORING AND TIE-DOWN OF ALL ROOF TOP
 MECHANICAL EQUIPMENT AND COMPONENTS INCLUDING THE ROOF
 AND EXTERIOR WALL-MOUNTED FANS, THE RTU'S, THE CU'S,
 THE RTU CURBS AND CU STANDS, THE DUCTWORK AND DUCT
 STANDS AND BRACKETS, ETC. . PLEASE NOTE THAT FLORIDA
 PRODUCT APPROVALS AND/OR MIAMI-DADE NOA'S ARE REQUIRED
 FOR THE CURBS AND STANDS WITH REVIEW AND APPROVAL
 SIGNATURES FROM THE DESIGN PROFESSIONAL OF RECORD-
 SECTION 301.15 MECHANICAL.
 21) M-2.7A & 7B: PLEASE INDICATE THE LOCATION OF CU-8
 ON THE ROOF PLAN.
 22) M-2.7A & 7B: REFER TO SECTION 3004 FBC-14
 MECHANICAL AND PROVIDE DETAILS FOR THE REQUIRED
 ELEVATOR HOISTWAY VENTING. SEE SECTION 3004.3 FOR
 SIZING.
 23) M-3.1A: EXHAUST SYSTEMS ARE REQUIRED FOR THE DOG
 PARLOR AND THE ZOOM LOCKERS ROOM- TABLE 403.3 FBC-14
 MECHANICAL.
 24) M-3.1A: PROVIDE DIMENSIONED ELEVATION VIEWS OF THE
 O/A INTAKES FOR AC- 4, 4A, AND 5 TO VERIFY THE
 LOCATIONS MEET THE REQUIRED CLEARANCES AS OUTLINED IN
 SECTION 401.4 FBC-14 MECHANICAL.
 25) M-3.1A: SHUT OFF DAMPER CONTROLS FOR THE O/A
 INTAKES ARE REQUIRED IN ACCORDANCE WITH SECTION
 C403.2.4.4 FBC-14 ENERGY CONSERVATION- INDICATE
 COMPLIANCE ON THE PLAN.
 26) M-3.1A: PLEASE CLARIFY HOW O/A IS BEING SUPPLIED TO
 AHU-9 SERVICING THE RESIDENTIAL LOBBY-N.
 27) M-3.1B: PROVIDE DIMENSIONED ELEVATION VIEWS OF THE
 O/A INTAKES FOR AC- 6, 7, & 8 TO VERIFY THE LOCATIONS
 MEET THE REQUIRED CLEARANCES AS OUTLINED IN SECTION
 401.4 FBC-14 MECHANICAL.
 28) M-3.1B: SHUT OFF DAMPER CONTROLS FOR THE O/A
 INTAKES ARE REQUIRED IN ACCORDANCE WITH SECTION
 C403.2.4.4 FBC-14 ENERGY CONSERVATION- INDICATE
 COMPLIANCE ON THE PLAN.
 29) M-3.1B: PROVIDE A CLEAR AIR DISTRIBUTION PLAN WITH
 NOTES AND DETAILS FOR AHU-8.
 30) M-3.1B: REFER TO SECTION 501.3.1 FBC-14 MECHANICAL
 AND INDICATE ALL REQUIRED CLEARANCE DISTANCE
 MEASUREMENTS FOR THE TOILET AND POOL BATHROOM EXHAUST
 FAN OUTLETS. CLARIFY IF CONDITIONED SUPPLY AIR OR
 MAKE-UP AIR WILL BE PROVIDED TO THE POOL BATHROOMS.
 31) M-3.1C: THE CITY OF WPB DEVELOPMENT SERVICES
 DIVISION REQUIRES A SEPARATE PERMIT AND PLANS FOR
 COMMERCIAL KITCHEN HOOD AND EXHAUST SYSTEMS. PLEASE
 INDICATE THAT THE NOTES AND DETAILS ON THE PLANS ARE
 FOR REFERENCE ONLY. A) PROVIDE NOTES AND DETAILS ON THE
 PLAN INDICATING THAT THE KITCHEN HOOD SUPPLY AIR INTAKE
 AND EXHAUST FAN DISCHARGE ARE IN COMPLIANCE WITH
 SECTIONS 401.4 AND 506.3.13.3 FBC-14 MECHANICAL.
 32) M-3.1C: VERIFY REQUIRED CLEARANCES FOR THE AHU-2
 O/A INTAKE AT THE SOUTH WALL OF THE THEATER.
 33) M-3.1C: PROVIDE WIND LOAD TIE-DOWN ENGINEERING FOR
 CU-2 & 3, & RTU- A & B- SECTION 301.15 FBC-14
 MECHANICAL.
 34) M-3.1C: THE 450 O/A CFM'S FOR RTU-B LISTED IN THE
 AIR BALANCE SCHEDULE DOES NOT MATCH WITH THE 325 CFM'S
 FOR THE CLUB LOUNGE LISTED IN THE O/A CALCULATIONS ON
 SHEET M-5.3.
 35) M-3.1C: DEMAND CONTROLLED VENTILATION IS REQUIRED
 FOR THE FITNESS ROOM IN ACCORDANCE WITH SECTION
 C403.2.5.1 FBC-14 ENERGY CONSERVATION. INDICATE HOW
 COMPLIANCE WITH THIS SECTION WILL BE MET (I.E.) THE USE
 OF CO2 DETECTORS.
 36) M-3.1C: PROVIDE ENLARGED TYPICAL DRAWINGS OF THE
 AHU'S IN THE CLOSETS INDICATING REQUIRED CLEARANCES,
 CONDENSATE DISPOSAL DETAILS, CLOSET CONSTRUCTION AND
 LOUVERED DOOR MATERIALS- REFER TO SECTION 602.1 FBC-14
 MECHANICAL AND C403.2.7.2 FBC-14 ENERGY CONSERVATION.
  
 37) RESIDENTIAL PLANS M-4.1, M-4.1, & M-4.3:
 A) PROVIDE AHRI CERTIFICATES FOR THE AC SYSTEMS.
 B) REFER TO COMMENT #2 OF THIS REVIEW FOR AC LOAD
 CALCULATION REQUIREMENTS.
 C) PLACE A NOTE THAT THE BEDROOM DOORS WILL EACH HAVE A
 1" UNDERCUT PER SECTION 601.5 FBC-14 MECHANICAL.
 D) REFER TO COMMENT #3 FOR O/A CALCULATIONS REQUIRED
 FOR THE RESIDENTIAL UNITS AND SHOW COMPLIANCE.
 E) PROVIDE SHUTOFF DAMPER CONTROLS FOR THE O/A INTAKES.
 F) PROVIDE CLEARANCE DISTANCE MEASUREMENTS OR NOTES ON
 THE PLAN INDICATING COMPLIANCE WITH SECTIONS 401.4
 FBC-14 MECHANICAL.
 G) INDICATE COMPLIANCE WITH SECTION 401.5 FOR THE O/A
 OPENING PROTECTION.
 H) PROVIDE A PRODUCT APPROVAL OR NOA FOR THE O/A
 LOUVER.
 I) KITCHEN VENTILATION: SHOW COMPLIANCE WITH TABLE
 403.3 FOR REQUIRED EXHAUST RATE IN THE KITCHENS. IF
 RANGE HOODS ARE TO BE USED, PROVIDE AN EQUIPMENT
 SCHEDULE ON THE PLAN AND SUBMIT SPECIFICATIONS REVIEWED
 AND APPROVED BY THE DESIGN PROFESSIONAL OF RECORD.
 J) INDICATE THE TOTAL RUN LENGTHS OF THE DRYER EXHAUST
 RUNS AND SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE
 DRYERS REVIEWED AND APPROVED BY THE DESIGN PROFESSIONAL
 OF RECORD.
  
 39) M-7.1: DETAIL 10- INDICATE THAT THE LOUVERED CLOSET
 DOORS WILL BE NON-COMBUSTIBLE FOR ALL AC CLOSETS
 INCLUDING THE RESIDENTIAL UNITS.
 40) M-7.2: PROVIDE FIRESTOPPING DETAILS FOR DUCTS
 PENETRATING FIRE-RATED WALLS AND SHAFTS.
 41) M-7.2, DETAIL 5: THE NOA #07-0509.09 SPECIFIED IS
 OUTDATED AND HAS BEEN SUPERSEDED. PLEASE PROVIDE A
 CURRENT NOA #.
 42) M-7.2, DETAIL 5: THE ASCE 7-05 REFERENCED IN THE
 DETAIL IS OUTDATED. ASCE 7-10 IS THE CURRENT STANDARD
 IN EFFECT.
 43) PROVIDE REFRIGERANT PIPING RISER DRAWINGS FOR THE
 AMENITY AC SYSTEMS 4-9, AND MANUFACTURER?S LINE LENGTH
 SPECIFICATIONS AND LIMITATIONS. B) PROVIDE THE TYPE AND
 SIZE OF REFRIGERANT PIPE INSULATION AND INDICATE HOW
 THE INSULATION SHALL BE PROTECTED FROM UV AND
 WEATHERING DEGRADATION.
 44) REFER TO SECTION C403.2.10 FBC-14 ENERGY
 CONSERVATION AND PROVIDE EVIDENCE OF COMPLIANCE-
 C403.2.10.1 ALLOWABLE FAN MOTOR HORSEPOWER.
 EACH HVAC SYSTEM AT FAN SYSTEM DESIGN CONDITIONS SHALL
 NOT EXCEED THE ALLOWABLE FAN SYSTEM MOTOR NAMEPLATE HP
 (OPTION 1) OR FAN SYSTEM BHP (OPTION 2) AS SHOWN IN
 TABLE C403.2.10.1(1). THIS INCLUDES SUPPLY FANS,
 RETURN/RELIEF FANS, AND FAN-POWERED TERMINAL UNITS
 ASSOCIATED WITH SYSTEMS PROVIDING HEATING OR COOLING
 CAPABILITY. SINGLE ZONE VARIABLE-AIR-VOLUME SYSTEMS
 SHALL COMPLY WITH THE CONSTANT VOLUME FAN POWER
 LIMITATION.
 EXCEPTION: THE FOLLOWING FAN SYSTEMS ARE EXEMPT FROM
 ALLOWABLE FAN FLOOR HORSEPOWER REQUIREMENT.
 1. HOSPITAL, VIVARIUM AND LABORATORY SYSTEMS THAT
 UTILIZE FLOW CONTROL DEVICES ON EXHAUST AND/OR RETURN
 TO MAINTAIN SPACE PRESSURE RELATIONSHIPS NECESSARY FOR
 OCCUPANT HEALTH AND SAFETY OR ENVIRONMENTAL CONTROL
 SHALL BE PERMITTED TO USE VARIABLE VOLUME FAN POWER
 LIMITATION.
 2. INDIVIDUAL EXHAUST FANS WITH MOTOR NAMEPLATE
 HORSEPOWER OF 1 HP OR LESS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2016-10-21 Cont ID  
Sent By gjohnson Date 2016-10-21 Time 12:59 Rev Time 0.00
Received By gjohnson Date 2016-10-21 Time 12:59 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2016-09-12 Cont ID  
Sent By gjohnson Date 2016-09-12 Time 13:06 Rev Time 0.00
Received By gjohnson Date 2016-09-12 Time 13:06 Sent To  
Notes
2016-09-12 14:05:143RDT REVIEW
  
  
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
  
 PLUMBING COMMENTS:
  
 1. SHT. A-10.6 PLEASE SHOW COMPLIANCE WITH FBC ACC.
 604.7 DISPENSERS.
 TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230
 MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO
 THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE
 DISPENSER SHALL BE 15 INCHES (380 MM) MINIMUM AND 48
 INCHES (1220 MM) MAXIMUM ABOVE THE FINISH FLOOR AND
 SHALL NOT BE LOCATED BEHIND GRAB BARS. DISPENSERS SHALL
 NOT BE OF A TYPE THAT CONTROLS DELIVERY OR THAT DOES
 NOT ALLOW CONTINUOUS PAPER FLOW.
  
 2. THE KITCHEN SINK IN CH 103 SHALL DRAIN THRU GREASE
 INTERCEPTOR. PER FBC PL 1003.1
  
 3. SHT.P2.1B ON THE OUTLET SIDE OF GREASE INTERCEPTOR A
 ONE DIRECTIONAL CLEAN IS SHOWN PLEASE SHOW A TWO WAY
 CLEAN OUT. ALSO DOWN STEAM OF THE CLEANOUT WE REQUIRE A
 TEST PORT MIN SIZE IS 6IN. PER WPB UTIL. DEPT.
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2016-06-15 Cont ID  
Sent By gjohnson Date 2016-06-16 Time 08:23 Rev Time 0.00
Received By gjohnson Date 2016-06-06 Time 16:42 Sent To  
Notes
2016-06-15 16:09:58 
 2ND REVIEW: FBC 2014
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  
 FAIR HOUSING AND ACCESSIBILITY COMMENTS:
  
 PREVIOUS COMMENTS
 #3. DID NOT COMPLY PLEASE SHOW THE MIN AND MAX
 DIMINSIONS OF THE REINFORCEMENT FOR THE GRAB BARS
 MEASURED FROM FINISHED FLOOR TO THE BOTTOM AND TOP OF
 REINFORCEMENT. PER FHA DESIGN MANUAL REQUIREMENT 6
  
 #8 DID NOT COMPLY PLEASE SHOW DEMINSIONS OF VANITY FROM
 FRONT TO BACK NOT SIDE TO SIDE. PER FHA DESIGN MANUAL
 REQUIREMENT 5
  
 #10 DID NOT COMPLY PLEASE SHOW DEMINSION OF THE WING
 WALL ON RIGHT SIDE OF TOILET FROM BACK OF TOILET TO THE
 END OF THE WALL. PER FHA DESIGN MANUAL REQUIREMENT 7
 PART B
  
 NEW COMMENTS:
 1. SHT. A-5.1.5 SHOW THE CLEAR FLOOR SPACE FOR ALL
 ACCESSIBLE FIXTURES IN EACH BATHROOM AND BREAKROOM SINK
 IN LEASING OFFICE. PER FBC ACC. SEC. 305
  
 2. SHT. A-5.1.5 DETAIL A THE URINAL IS SHOWN AS
 STANDARD PER ACCESSIBILITY LEGEND IT NEEDS TO BE SHOWN
 AS ACCESSIBLE. PER FBC ACC. SEC 605
  
 3. THE BREAKROOM SINK IN LEASING OFFICE SHALL COMPLY
 WITH FBC ACC. SEC. 606.3 HEIGHT.
 LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT
 OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES
 (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 PLUMBING COMMENTS:
  
 PREVIOUS COMMENTS:
  
 #11 DID NOT COMPLY SHT. P-6.2 DETAIL #2 STILL SHOWS
 SUCTION AS 5IN EVERYTHING ELSE IS SHOWN AS 6IN. PLEASE
 CLARIFY. PER WPB AMEND. TO FBC SEC.107.2.1
  
 # 18 DID NOT COMPLY PROVIDE DETAIL WITH THE DEMISIONS
 AND THE SQUARE FOOTAGE THAT IT IS SERVING FOR OVERFLOW
 SCUPPERS. PER WPB AMEND. TO FBC SEC.107.2.1
  
 #20 DID NOT COMPLY PLEASE PROVIDE DEMINSIONS OF STORM
 SUMP PIT. PER WPB AMEND. TO FBC SEC.107.2.1
  
 NEW COMMENTS:
  
 1. CUB HOUSE KITCHEN SINK AND MOP SINK ALONG WITH 3
 COMPARTMENT SINK SHALL DRAIN THROUGH GREASE
 INTERCEPTOR. PER FBC PL SEC. 1003.1 WHERE REQUIRED.
 INTERCEPTORS AND SEPARATORS SHALL BE PROVIDED TO
 PREVENT THE DISCHARGE OF OIL, GREASE, SAND AND OTHER
 SUBSTANCES HARMFUL OR HAZARDOUS TO THE PUBLIC SEWER,
 THE PRIVATE SEWAGE SYSTEM OR THE SEWAGE TREATMENT PLANT
 OR PROCESSES.
  
 2. SHT. P-2.1B MATCHLINE P-2.1B APPEARS TO BE INCORRECT
 IT SHOULD BE P-2.1A PLEASE CLARIFY. PER WPB AMEND. TO
 FBC SEC.107.2.1
  
  
 DO TO PLANS BEING INCOMPLETE OR UNCLEAR, A
 COMPREHENSIVE PLAN REVIEW CANNOT BE DONE AT THIS TIME,
 THERE MAYBE ADDITIONAL COMMENTS ON RESUBMITTAL OF
 PLANS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND LEAVE THE
 PREVIOUSLY REVIEWED SHEETS.
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-03-11 Cont ID  
Sent By gjohnson Date 2016-03-11 Time 09:22 Rev Time 0.00
Received By gjohnson Date 2016-02-27 Time 07:21 Sent To  
Notes
2016-03-10 14:28:401ST REVIEW: FBC 2014
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 (FHA)
  
 1. SHT. A-10.4 UNIT C2 WHAT SPECIFICATION IS THE MASTER
 BATH.
 UNDER FAIR HOUSING ACT DESIGN MANUAL REQUIREMENT7 PART
 B
 2. A CLEAR FLOOR SPACE WITH A PARALLEL APPROACH IS
 REQUIRED FOR ALL SHOWERS.
 UNDER FAIR HOUSING ACT DESIGN MANUAL REQUIREMENT7 PART
 B
 3. SHOW HEIGHT OF REINFORCEMENT FOR GRAB BARS AND
 SHOWER SEATS.
 UNDER FAIR HOUSING ACT DESIGN MANUAL REQUIREMENT 6
 4. SHT. A-10.4 UNIT C1 ALL SHOWERS SHALL HAVE PARALLEL
 APPROACH CLEAR FLOOR SPACE SHOWERS IN TYPE A BATHROOM
 CANNOT COMPLY.
 UNDER FAIR HOUSING ACT DESIGN MANUAL REQUIREMENT7 PART
 B
 5. SHT. A-10.4 UNIT C3 A MEANS OF PROVIDING KNEE SPACE
 FOR LAVATORY'S WITH FRONT APPROACH CLEAR FLOOR SHALL BE
 SHOWN ON PLANS.
 UNDER FAIR HOUSING ACT DESIGN MANUAL REQUIREMENT7 PART
 B
 6. SHT. A-10.1 UNITS S1-S2-A4 SHOW CLEAR FLOOR SPACE
 FOR TUBS.
 UNDER FAIR HOUSING ACT DESIGN MANUAL REQUIREMENT7 PART
 B
 7. SHT. A10.1 UNIT A1-3 MIN. DIMENSION OF SHOWER DOOR
 SHOULD BE 32IN. WIDE.
 UNDER FAIR HOUSING ACT DESIGN MANUAL REQUIREMENT7 PART
 B
 8. PLEASE INDICATE DEPTH OF LAVATORY VANITY MAX. OF
 24IN. .
 UNDER FAIR HOUSING ACT DESIGN MANUAL REQUIREMENT5
 9. SHT.A01.4 UNIT C1 CLEAR FLOOR SPACE FOR TUB SHALL BE
 FLUSH WITH CONTROL WALL OF TUB.
 UNDER FAIR HOUSING ACT DESIGN MANUAL REQUIREMENT7 PART
 B
 10. SHT. A-10.4 UNIT C3 WING WALL NEXT TO TOILET SHALL
 BE MAX OF 24IN.
 UNDER FAIR HOUSING ACT DESIGN MANUAL REQUIREMENT7 PART
 B
 11. PLEASE SHOW IN ALL KITCHENS A 3'-4" CLEARANCE
 BETWEEN APPOSING CABINETS AND APPLIANCES.
 UNDER FAIR HOUSING ACT DESIGN MANUAL REQUIREMENT7 PART
 A
  
 (PLUMBING)
  
 1. SHT.P-2.1A STACK B1 SHALL CONNECT TO BUILDING DRAIN
 DOWN STREAN OF THE POOL BATHROOM GROUP MENS BATH.
 PER FBC PL SEC. 912.1
 2. PLEASE PROVIDE MANUFACTURE SPEC SHEETS AND SIZING
 CALCULATIONS FOR GREASE INTERCEPTOR IN KITCHEN OF
 CLUBHOUSE.
 WPB AMEND. TO FBC SEC. 107.2.1.3
 3. THERE IS NO FLOOR DRAIN IN TRASH SHUTE ROOMWHERE
 WILL WATER DRAIN WHEN FLOOR IS DRAINED.
 WPB AMEND. TO FBC SEC. 107.2.1
 4. SHT. P-5.5 MOP SINK IN MAINTANCE ROOM IS NOT SHOWN
 ON RISER DIAGRAM PLEASE CLARIFY.
 WPB AMEND. TO FBC SEC. 107.2.1
 5. SHT. P5.3 STACK C-C1-C2 SHOWS THE WC, SH. AND LAV
 BRANCH FITTINGS ARE STACKED ON TOP OF EACH OTHER, IS
 THIS THE WAY IT WILL BE PIPED UNDER THE SLAB, IT WILL
 BE DEFACUIT TO DO IT THAT WAYPLEASE CLARIFY.
 MAY BE UNDERSIZED.
 PER FBC PL TABLE E201.1
 6. P-5.7 PROVIDE SANITARY AND WATER RISER DIAGRAM
 BATHROOMS IN OFFICES AND LEASING CENTER.
 WPB AMEND. TO FBC SEC. 107.3.5.1.3
 7. SHT. C-09 THE TOTAL DFU'S OF THE BUILDING SEWER
 EXCEEDS THE MAXIMUM ALLOWED ON THE EXISTING 8" CITY
 SEWER LATERAL .
 PER FBC PL TABLE 710.1(1) CONTACT MANUAL GONZALEZ AT
 561-494-1040 EX.1085
 8. SHT. P-5.1 UNIT C1- C2 THE 1/2" COLD WATER LINE
 SUPPLING THE MASTER BATH AND WASHING MACHINE MAY BE
 UNDERSIZED.
 PER FBC PL TABLE E201.1
 9. SHT. P-5.1 UNIT A1-4 THE 1/2" COLD WATERLINE
 SUPPLYING BOTH BATHROOMS MAY BE UNDERSIZED.
 PER FBC PL TABLE E201.1
 10. SHT. P-5.2 RISER #3 MAY BE UNDERSIZED.
 PER FBC PL TABLE E201.1
 11. SHT. P-6.2 DETAIL #2 SHOWS 5" SUCTION AND DISCHARGE
 DETAIL #3 AND SHT.P-5.7 SHOWS 6" PLEASE CLARIFY.
 WPB AMEND. TO FBC SEC. 107.2.1
 12. PLEASE PROVIDE MANUFACTURE SPECS FOR DOMESTIC
 PUMP,WATER HEATERS, SUMP PUMPS, OIL SPILL ALARM.
 WPB AMEND. TO FBC SEC. 107.2.1
 13. SHOW DRAINS FOR ELEVATOR SUMP PITS ON SANITARY
 COLLECTION DIAGRAM.
 WPB AMEND. TO FBC SEC. 107.2.1
 14. SHT. P-2.7A+B THE MATCH LINES REFER TO P-2.6 A+B IS
 THIS CORRECT P-2.7 ARE ROOF PLANS AND P-2.6 ARE EIGHT
 FLOOR PLANS PLEASE CLARIFY.
 WPB AMEND. TO FBC SEC. 107.2.1
 15. SHT. P-2.7 B RD ON TOP OF STAIRWELL #1 IS NOT SHOWN
 ON RISER DIAGRAM PLEASE CLARIFY.
 WPB AMEND. TO FBC SEC. 107.2.1
 16. SHT. P-2.7A WHERE IS THE RAIN WATER FROM ELEVATOR
 SHAFT ROOF DRAIN TO.
 WPB AMEND. TO FBC SEC. 107.2.1
 17. SHOW OVERFLOW SCUPPERS ON ROOF PLAN WITH DETAILS.
 WPB AMEND. TO FBC SEC. 107.2.1
 18. PLEASE CLARIFY HOW ARE YOU DRAINING ROOF OF
 CLUBHOUSE SHT. P-5.8 SHOWS STORM DRAIN FOR CLUB HOUSE
 BUT NO RISER DIAGRAM.
 WPB AMEND. TO FBC SEC. 107.2.1
 19. PROVIDE DETAIL FOR STORM SUMP PIT NEXT TO BICYCLE
 RACK.
 WPB AMEND. TO FBC SEC. 107.2.1
 20. SHT. A-5.1.5 SHOWS TOILET CLEARANCE OFF SIDE WALLAT
 18 MIN. IT SHOULD SHOW 16" MIN 18" MAX TO COMPLY WITH
 FBC ACC. SEC. 604.2 ALL PUBLIC ACC. TOILETS SHALL
 COMPLY.
 21. FLUSHING RING REQUIRED ON TRASH AND RECYCLING
 SHUTE. PROVIDE DETAIL AND SHOW ON WATER RISER DIAGRAM.
 WPB AMEND. TO FBC SEC. 107.2.1
  
 (IRRIGATION)
  
 1. SHT. LR-1 NOTER ON WATER SUPPLY FOR FOUNTAIN TO PUMP
 VAULT CONNECT BETWEEN PVB AND MASTER VALVE IS THAT
 CONNECTION BEING MADE ON THE DOWN STREAM SIDE OF PVB.
 WPB AMEND. TO FBC SEC. 107.2.1
 2. SHOW LOCATION OF RAIN SENSOR.
 WPB AMEND. TO FBC SEC. 107.2.1
 3. SHT. LR-1A CLUBHOUSE DECK IRRIGATION SHALL HAVE
 BACKFLOW PROTECTION IF CONNECTED TO POTABLE WATER
 SYSTEM AND BE SHOWN ON RISER DIAGRAM.
 WPB AMEND. TO FBC SEC. 107.2.1
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status N Date 2016-09-09 Cont ID  
Sent By shill Date 2016-09-09 Time 15:37 Rev Time 0.00
Received By shill Date 2016-09-09 Time 15:37 Sent To  
Notes
2016-09-09 15:38:53PRODUCT APPROVALS REVIEWED BY DESIGNER OF RECORD WILL
 BE REQUIRED TO BE SUBMITTED WITH A ROOF PERMIT
 APPLICATION PRIOR TO INSTALLATION.
  
 ROOF CONTRATOR IS TO INDICATE ASSEMBLY PROPOSED AND TO
 INCLUDE ENHANCED FASTENING ENGINEERING IF APPLICABLE.
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status N Date 2016-06-29 Cont ID  
Sent By shill Date 2016-06-29 Time 13:57 Rev Time 0.00
Received By shill Date 2016-06-29 Time 13:57 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2016-03-11 Cont ID  
Sent By shill Date 2016-03-11 Time 14:02 Rev Time 0.00
Received By shill Date 2016-03-11 Time 14:02 Sent To  
Notes
2016-03-11 14:14:51****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 ROOF NOAS FOR JM TPO SUBMMITTED; 14-0618.03, 13-0529.02
  
 1. ROOF PRODUCT APPROVALS WERE SUBMITTED BUT THE
 ASSEMBLY PROPOSED WAS NOT SELECTED AND ENGINEERING FOR
 ENHANCED FASTENING (WOOD DECK) WAS NOT PROVIDED. IF
 THIS INFORMATION IS NOT PROVIDED PRIOR TO PERMIT
 ISSUANCE, THE INFORMATION WILL BE REQUIRED AT TIME OF
 ROOF SUB PERMIT SUBMITTAL. AN "N" WILL BE ENTERED FOR
 THE ROOF PLAN REVIEW.
  
 ROOF ASSEMBLIES SELECTED TO COMPLY WITH THE (VULT)
 PRESSURES SPECIFIED ON SHEET S6-1.
  
 2. SHEET S6-1, CLARIFY PURPOSE OF "ROOF MEMBRANE DESIGN
 PRESSSURE" VS. "GROSS UPLIFT DESIGN PRESSURES." THE
 DESIGN PRESSURES TO BE UTILIZED FOR THE TPO ROOF IS NOT
 CLEAR.
  
 3. SHEET S6-1, ROOF PRESSURES SPECIFIED USE ZONE 2
 PRESSURES FOR ZONE 3. IT APPEARS THAT THE STAIR ROOF,
 ELEVATOR ROOF DO NOT INCLUDE A 3FT PARAPET, FBC 1609,
 ASCE7 10 30.6-1 NOTE 7.
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2016-10-27 Cont ID  
Sent By shill Date 2016-10-27 Time 17:22 Rev Time 0.00
Received By shill Date 2016-10-27 Time 17:22 Sent To  
Notes
2016-10-28 09:32:4710/28/16
 PLUMBING PROVISO:
  
 PLUMBING PAGES P2.1C ,P2.2C, P2.3C, P2.5B, P2.6B, P4.1,
 P4.2, P4.3, P5.1, P5.2, P5.3, P5.4, P5.5, P5.7, P5.8,
 P5.9, P6.1, P6.3, P6.4. HAVE A WET STAMP BY ONE
 ENGINEER AND A DIGITAL STAMP BY A DIFFERENT ENGINEER.
 PLEASE RESUBMIT THESE PAGES WITH A SINGLE ENGINEER.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
2016-10-27 17:23:10PROVISO
  
 PLUMBING PAGES SIGNATURE DOCUMENT REQUIRED
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2016-10-27 Cont ID  
Sent By shill Date 2016-10-27 Time 16:08 Rev Time 0.00
Received By shill Date 2016-10-27 Time 16:08 Sent To  
Notes
2016-10-27 17:22:28SOME PLUMBING SHEETS WERE PREPARED BY ONE ENGINEER AND
 DIGITALLY SIGNED AND SEALED BY A DIFFERENT ENGINEER.
  
  
2016-10-27 15:15:52DIGITAL SIGNATURES FOR MECHANICAL PLANS AND
 CALCULATIONS VERIFIED/CC
 10/27/2016
2016-10-21 14:38:4810/21/16 3RD BUILDING REVIEW, SIGNATURE / SEAL
 VERIFICATION
  
 THE FOLLOWING HAVE BEEN REVIEWED AND APPROVED:
  
 9/9/16, 6/7/16 VERIFIED A & S SHEET DIGITAL SIGNATURES,
 2ND & 3RD REVIEW & BUILDING SUBMITTALS (SH)
  
 9/9/16 DIGITAL SIGNATURE ON STRUCTURAL CALCS VERIFIED
 ORIGINAL SIGNED & SEALED SOILS REPORT WAS PROVIDED FOR
 PERMIT 16020199 (VIBROFLOTATION PERMIT)
 DIGITAL SIGNATURES ON EACH SHEET (S, LS, A, GA) OK
 ORIGINAL SURVEY NOT REQUIRED AS IT IS NOW SUPERSEDED BY
 REPLAT RECORDED BOOK 122, PAGES 16-17.
  
  
2016-06-09 12:52:036/9/16
 CCOLE
  
 EACH UPLOADED WIND LOAD ENGINEERING DOCUMENT FOR THE
 CARRIER, MITSUBISHI, FIRST COMPANY UNITS, AND FOR THE
 ROOF STANDS AND WALL BRACKETS HAVE SCANNED ENGINEER'S
 SEALS- EACH MUST BE DIGITALLY SIGNED AND SEALED BY THE
 ENGINEER WHO PREPARED THEM. THE DOCUMENTS MUST ALSO BE
 APPROVED WITH SIGNATURE BY THE ENGINEER OF RECORD.
2016-06-07 07:23:539/9/2016 FAILED
  
 1. ENERGY CALCS AND SOME MECHANICAL PAGES (FOR
 EXAMPLES, SEE SHEETS M2.6B, M2.3B, CHECK ALL) ARE
 PREPARED BY ALEJANDRO FRANYIE, BUT IS DIGITALLY SIGNED
 AND SEALED BY VIVIANA FRANYIE.
 2. SEE ALSO OTHER REVIEWER('S) LIST(S).
  
 THE FOLLOWING HAVE BEEN REVIEWED AND APPROVED:
  
 9/9/16, 6/7/16 VERIFIED A & S SHEET DIGITAL SIGNATURES,
 2ND SUBMITTAL & 3RD SUBMITTALS (SH)
  
 9/9/16 DIGITAL SIGNATURE ON STRUCTURAL CALCS VERIFIED
 ORIGINAL SIGNED & SEALED SOILS REPORT WAS PROVIDED FOR
 PERMIT 16020199 (VIBROFLOTATION PERMIT)
 DIGITAL SIGNATURES ON EACH SHEET (S, LS, A, GA) OK
 ORIGINAL SURVEY NOT REQUIRED AS IT IS NOW SUPERSEDED BY
 REPLAT RECORDED BOOK 122, PAGES 16-17.
  
 3/16 ALL TITLE BLOCKS CHECKED, LICENSES VERIFIED
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2016-03-16 Cont ID  
Sent By shill Date 2016-03-16 Time 13:57 Rev Time 0.00
Received By shill Date 2016-03-16 Time 13:57 Sent To  
Notes
2016-03-16 12:41:543/16 ALL TITLE BLOCKS CHECKED, LICENSES VERIFIED
 DIGITAL SIGNATURE OR BACKUP DOCUMENTS REQUIRED FOR
 SOILS REPORT, SURVEY, STRUCTURAL CALCS
 SEE BUILDING COMMENT REGARDING SOILS REPORT
 DIGITAL SIGNATURES ON EACH SHEET WILL BE REVIEWED PRIOR
 TO PERMIT ISSUANCE
  
  

Review Stop THRESHOLD THRESHOLD INSPECTOR DOCUMENTS
Rev No 3 Status P Date 2016-09-16 Cont ID  
Sent By shill Date 2016-09-16 Time 06:35 Rev Time 0.00
Received By shill Date 2016-08-22 Time 14:55 Sent To  
Notes
2016-09-16 06:35:339/16 OK PER KC
  
2016-08-22 14:55:448/22 ALL DOCUMENTS RECEIVED AND COMPLETE; ROUTED TO KEN
 CONRAD DESK FOR APPROVAL
  
  

Review Stop THRESHOLD THRESHOLD INSPECTOR DOCUMENTS
Rev No 2 Status F Date 2016-06-28 Cont ID  
Sent By shill Date 2016-06-28 Time 14:10 Rev Time 0.00
Received By shill Date 2016-06-28 Time 14:10 Sent To  
Notes
2016-06-06 16:37:34****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. A RESUME FOR ENRIQUE XAVIER BURBANO WAS SUBMITTED,
 BUT THIS INSPECTOR HAS NOT SIGNED THE SPECIAL INSPECTOR
 AGREEMENT.
  
 2. A RESUME FOR THE CONTRACTOR (ALLIANCE RESIDENTIAL
 BUILDERS) HAS NOT BEEN SUBMITTED.
  
 AFTER ALL DOCUMENTS HAVE BEEN RECEIVED, THE PACKAGE
 WILL BE FORWARDED TO KEN CONRAD FOR APPROVAL. THESE
 DOCUMENTS MAY BE SENT VIA EMAIL.
  
  

Review Stop THRESHOLD THRESHOLD INSPECTOR DOCUMENTS
Rev No 1 Status F Date 2016-03-01 Cont ID  
Sent By shill Date 2016-03-01 Time 17:13 Rev Time 0.00
Received By shill Date 2016-02-29 Time 18:45 Sent To  
Notes
2016-03-01 17:13:38****CORRECTIONS****
 PLAN REVIEW IN PROGRESS
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 SI AGREEMENT AND POLICY SENT TO [email protected]
 VIA EMAIL ON 3/1/16
  
  

Review Stop Z ZONING
Rev No 4 Status P Date 2016-10-26 Cont ID  
Sent By aaponte Date 2016-10-26 Time 09:53 Rev Time 0.00
Received By aaponte Date 2016-10-26 Time 09:53 Sent To  
Notes
2016-10-26 09:55:23PROVISO: 1. BEFORE FINAL CO A SIDEWALK ACCESS EASEMENT
 WILL BE REQUIRED ALONG QUADRILLE BOULEVARD.
 2. BEFORE FINAL CO A MAINTENANCE AGREEMENT WILL BE
 REQUIRED FOR THE MAINTENANCE OF ANY LANDSCAPE,
 IRRIGATION, TREE GRATES AND SPECIALY PAVERS INSTALLED
 WITHIN THE ROW.

Review Stop Z ZONING
Rev No 3 Status F Date 2016-09-16 Cont ID  
Sent By aaponte Date 2016-09-16 Time 08:56 Rev Time 0.00
Received By aaponte Date 2016-09-16 Time 08:56 Sent To  
Notes
2016-09-16 09:25:541. REPLAT- DONE.
 2. BEFORE FINAL CO A SIDEWALK ACCESS EASEMENT WILL BE
 REQUIRED ALONG QUADRILLE BOULEVARD.
 3. BEFORE FINAL CO A MAINTENANCE AGREEMENT WILL BE
 REQUIRED FOR THE MAINTENANCE OF ANY LANDSCAPE,
 IRRIGATION, TREE GRATES AND SPECIALY PAVERS INSTALLED
 WITHIN THE ROW.
 4. NOT SAFISFIED- SECTION AA ON SHEET C-6 SHOWS THE
 CROSS SLOPE BUT DOES NOT CONFIRM THE SIDEWALK ELEVATION
 IS MAINTAINED AS IT CROSSES DRIVEWAY AREA. STAFF
 SENDING E-MAIL WITH FURTHER EXPLANATION.- PLEASE
 CONFIRM THAT ANY VEHICULAR ENTRANCE IS DESIGNED TO HAVE
 THE PEDESTRIAN CROSSING AREA AT THE SAME LEVEL OF THE
 ADJACENT SIDEWALK.PLEASE PROVIDE DETAILS WITH SECTION.
 5. DONE-PLEASE CONSIDER THE PROPOSED DESIGN FOR THE
 PUBLIC OPEN SPACE TO LOCATE THE YARD DRAIN
 LINESINDICATED IN CIVIL DRAWINGS.
 6.DONE- ANY ABOVE GROUND UTILITY EQUIPMENT SHALL BE
 LOCATED AWAY FROM PUBLIC VIEW AND SCREENED WITH
 VEGETATION.
 7. NOT-SATISFIED - PLEASE PROVIDE PHOTOMETRICS OF ALL
 THE AREAS OUTSIDE THE BUILDING, INCLUDING THE SIDEWALK
 TO CONFIRM COMPLIANCE WITH THE 0.6 FOOTCANDLE AT1 FOOT
 ABOVE THE SIDEWALK AT THEBACK OF CURB LINE (SEC
 94-113(B)).
 8. DONE- THE REMOVAL OF THE WINDOWS ABOVE THE GARAGE
 ENTRANCE IMPACTS THE APPEARANCE OF VEHICULAR ENTRANCE.
 THE DOUBLE HEIGHT OPENING WAS ORIGINALLY MITIGATED BY
 THE WINDOWS. PLEASE PROVIDE AN ALTERNATIVE TO MINIMIZE
 THE VISUAL IMPACT OF THE GARAGE ENTRANCE. A DIFFERENT
 DECORATIVE ELEMENT CAN BE PROVIDED AT THE FACADE LINE
 TO REDUCE THE HEIGHT OF THE GARAGE OPENING TO THE
 MINIMUM CLEARANCE NEEDED FOR VEHICULAR ACCESS.
 9. DONE-PLEASE INDICATE IF THE PROPOSED TENANT STORAGE
 HAS AC AND IT IS FULLY ENCLOSED (SEE SEC 94-109
 DEFINITION OF GROSS BUILDING AREA).
 10. DONE- PARKING PAINTING DETAIL FOR ON-STREET PARKING
 AND ON-SITE PARKING SHALL MEET CITY'S PAINTING DETAIL
 INCLUDED IN SEC 94-485.
 11. DONE-PLEASE ADJUST ALL DRAWINGS FOR CONSISTENCY
 WITH REVISED OPEN SPACE DESIGN.
 12. DONE-PLEASE PROVIDE INFORMATION TO CONFIRM
 COMPLIANCE WITH COVERED AREAS FOR GARGARE ROOF LEVEL.
 13. PLEASE SUBMIT A RESPONSE LETTER EXPLAINING HOW THE
 COMMENTS HAVE BEEN ADDRESSED.
 14. DONE-A SEPARATE LANDSCAPE AND IRRIGATION PERMIT IS
 REQUIRED. PLEASE SUBMIT SEPARATE APPLICATION FOR
 REVIEW.
 FOR ADDIITONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.

Review Stop Z ZONING
Rev No 2 Status F Date 2016-07-29 Cont ID  
Sent By aaponte Date 2016-07-29 Time 11:34 Rev Time 0.00
Received By aaponte Date 2016-07-29 Time 11:34 Sent To  
Notes
2016-07-29 13:10:591. REPLAT- DONE.
 2. A SIDEWALK ACCESS EASEMENT WILL BE REQUIRED ALONG
 QUADRILLE BOULEVARD.
 3. A MAINTENANCE AGREEMENT WILL BE REQUIRED FOR THE
 MAINTENANCE OF ANY LANDSCAPE, IRRIGATION, TREE GRATES
 AND SPECIALY PAVERS INSTALLED WITHIN THE ROW.
 4. PLEASE CONFIRM THAT ANY VEHICULAR ENTRANCE IS
 DESIGNED TO HAVE THE PEDESTRIAN CROSSING AREA AT THE
 SAME LEVEL OF THE ADJACENT SIDEWALK.PLEASE PROVIDE
 DETAILS WITH SECTION.
 5. DONE-PLEASE CONSIDER THE PROPOSED DESIGN FOR THE
 PUBLIC OPEN SPACE TO LOCATE THE YARD DRAIN
 LINESINDICATED IN CIVIL DRAWINGS.
 6. ANY ABOVE GROUND UTILITY EQUIPMENT SHALL BE LOCATED
 AWAY FROM PUBLIC VIEW AND SCREENED WITH VEGETATION.
 7. PLEASE PROVIDE PHOTOMETRICS OF ALL THE AREAS OUTSIDE
 THE BUILDING, INCLUDING THE SIDEWALK TO CONFIRM
 COMPLIANCE WITH THE 0.6 FOOTCANDLE AT1 FOOT ABOVE THE
 SIDEWALK AT THEBACK OF CURB LINE (SEC 94-113(B)).
 8. DONE- THE REMOVAL OF THE WINDOWS ABOVE THE GARAGE
 ENTRANCE IMPACTS THE APPEARANCE OF VEHICULAR ENTRANCE.
 THE DOUBLE HEIGHT OPENING WAS ORIGINALLY MITIGATED BY
 THE WINDOWS. PLEASE PROVIDE AN ALTERNATIVE TO MINIMIZE
 THE VISUAL IMPACT OF THE GARAGE ENTRANCE. A DIFFERENT
 DECORATIVE ELEMENT CAN BE PROVIDED AT THE FACADE LINE
 TO REDUCE THE HEIGHT OF THE GARAGE OPENING TO THE
 MINIMUM CLEARANCE NEEDED FOR VEHICULAR ACCESS.
 9. PLEASE INDICATE IF THE PROPOSED TENANT STORAGE HAS
 AC AND IT IS FULLY ENCLOSED (SEE SEC 94-109 DEFINITION
 OF GROSS BUILDING AREA).
 10. PARKING PAINTING DETAIL FOR ON-STREET PARKING AND
 ON-SITE PARKING SHALL MEET CITY'S PAINTING DETAIL
 INCLUDED IN SEC 94-485.
 11. PLEASE ADJUST ALL DRAWINGS FOR CONSISTENCY WITH
 REVISED OPEN SPACE DESIGN.
 12. PLEASE PROVIDE INFORMATION TO CONFIRM COMPLIANCE
 WITH COVERED AREAS FOR GARGARE ROOF LEVEL.
 13. PLEASE SUBMIT A RESPONSE LETTER EXPLAINING HOW THE
 COMMENTS HAVE BEEN ADDRESSED.
 14. A SEPARATE LANDSCAPE AND IRRIGATION PERMIT IS
 REQUIRED. PLEASE SUBMIT SEPARATE APPLICATION FOR
 REVIEW.
 FOR ADDIITONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.

Review Stop Z ZONING
Rev No 1 Status F Date 2016-04-08 Cont ID  
Sent By aaponte Date 2016-04-08 Time 16:32 Rev Time 0.00
Received By aaponte Date 2016-04-01 Time 11:37 Sent To  
Notes
2016-04-01 11:43:371.PROPERTY RE-PLAT IS REQUIRED. ALLEY ABANDONMENT
 PROCESS NEEDS COMPLETION (PAYMENT AND RECORDING) TO
 PROCEED WITH THE RE-PLAT. RESULTING SITE AREA IS
 117,949SF (2.7 ACRE) ACCORDING TO RE-PLAT DOCUMENTATION
 SUBMITTED NOV 18, 2015. PLEASE REVIEW AND CONFIRM
 INFORMATION.
 2. A SIDEWALK ACCESS EASEMENT WILL BE REQUIRED ALONG
 QUADRILLE BOULEVARD.
 3. A MAINTENANCE AGREEMENT WILL BE REQUIRED FOR THE
 MAINTENANCE OF ANY LANDSCAPE, IRRIGATION, TREE GRATES
 AND SPECIALY PAVERS INSTALLED WITHIN THE ROW.
 4. PLEASE CONFIRM THAT ANY VEHICULAR ENTRANCE IS
 DESIGNED TO HAVE THE PEDESTRIAN CROSSING AREA AT THE
 SAME LEVEL OF THE ADJACENT SIDEWALK.
 5. PLEASE CONSIDER THE PROPOSED DESIGN FOR THE PUBLIC
 OPEN SPACE TO LOCATE THE YARD DRAIN LINESINDICATED IN
 CIVIL DRAWINGS.
 6. ANY ABOVE GROUND UTILITY EQUIPMENT SHALL BE LOCATED
 AWAY FROM PUBLIC VIEW AND SCREENED WITH VEGETATION.
 7. PLEASE PROVIDE PHOTOMETRICS OF ALL THE AREAS OUTSIDE
 THE BUILDING, INCLUDING THE SIDEWALK TO CONFIRM
 COMPLIANCE WITH THE 0.6 FOOTCANDLE AT1 FOOT ABOVE THE
 SIDEWALK AT THEBACK OF CURB LINE (SEC 94-113(B)).
 8. THE REMOVAL OF THE WINDOWS ABOVE THE GARAGE ENTRANCE
 IMPACTS THE APPEARANCE OF VEHICULAR ENTRANCE. THE
 DOUBLE HEIGHT OPENING WAS ORIGINALLY MITIGATED BY THE
 WINDOWS. PLEASE PROVIDE AN ALTERNATIVE TO MINIMIZE THE
 VISUAL IMPACT OF THE GARAGE ENTRANCE. A DIFFERENT
 DECORATIVE ELEMENT CAN BE PROVIDED AT THE FACADE LINE
 TO REDUCE THE HEIGHT OF THE GARAGE OPENING TO THE
 MINIMUM CLEARANCE NEEDED FOR VEHICULAR ACCESS.
 9. PLEASE INDICATE IF THE PROPOSED TENANT STORAGE HAS
 AC AND IT IS FULLY ENCLOSED (SEE SEC 94-109 DEFINITION
 OF GROSS BUILDING AREA).
  
 FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA
 APONTE AT 561-822-1439.
  
  
2016-02-16 16:16:282/16/16