| Plan Review Stops For Permit 16020175 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2016-08-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-08-09 |
Time |
18:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-08-09 |
Time |
18:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2016-07-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-07-13 |
Time |
17:49 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-07-13 |
Time |
14:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-05-19 |
|
|
Cont ID |
|
| Sent By |
gearl |
Date |
2016-05-19 |
Time |
18:40 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-05-19 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2016-05-19 18:38:57 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE PROJECT IS LOCATED WITHIN 600 FEET OF THE | | | INTER-COASTAL WATERWAY. SURFACE ROUGHNESS D PREVAILS IN | | | THE UPWIND DIRECTION FOR AT LEAST 5,000 FEET. | | | THEREFORE, THIS PROJECT IS CONSIDERED TO BE EXPOSURE | | | CATEGORY D. FBC-R301.2.1.4.3 THE EXPOSURE CATEGORY HAS | | | NOT BEEN CHANGED ON THE PLANS. | | | | | | 2) REVIEW THE COMPONENT AND CLADDING WIND PRESSURES FOR | | | EXPOSURE D AND REVISE AS REQUIRED. FBC-R301.2.1 THE | | | COMPONENT AND CLADDING WIND PRESSURES HAVE NOT BEEN | | | CHANGED ON THE PLANS. | | | | | | 3) THE WINDOWS OF THE PROPOSED SECOND FLOOR BEDROOM | | | ABOVE THE EXISTING LIVING ROOM ARE REQUIRED TO COMPLY | | | WITH FBC-R310 FOR EMERGENCY ESCAPE AND RESCUE, THIS IS | | | NOT INDICATED ON THE PLANS. | | | | | | 4) PROVIDE DETAILS OF THE GUARDRAIL FOR THE MASTER | | | BEDROOM BALCONY. FBC-R312 | | | | | | 5) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 | | | THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. PROVIDE TWO COMPLETE PRODUCT | | | APPROVALS WITH FL OR NOA NUMBERS INCLUDING INSTALLATION | | | INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES FOR EACH OF | | | THE DIFFERENT ROOFING MATERIALS, WINDOW/GLASS TYPES, | | | STRUCTURAL MULLIONS AND EXTERIOR DOOR TYPES. NO PRODUCT | | | APPROVALS WERE SUBMITTED FOR THE STRUCTURAL MULLIONS. | | | | | | 6) THE PLANS SPECIFY CEMENT ROOF TILES AND PRODUCT | | | APPROVALS FOR TAMKO ASPHALT ASPHALT SHINGLES (NOA NO. | | | 11-1228.01) WERE SUBMITTED. THE PLANS WILL NEED TO BE | | | REVISED AND THE ASPHALT SHINGLES WILL NEED TO BE | | | APPROVED BY THE HISTORIC PLANNER. | | | | | | 7) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT A | | | RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | | COMMENTS HAS BEEN ADDRESSED. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | 2016-05-12 09:12:05 | 5/3/16 REVIEW COMMENTS DO NOT APPLY, PLEASE DISREGARD. | | 2016-05-03 13:14:25 | | | | | | | | | | 1. NEED TO HAVE A CLEAN OUT AT THE BASE OF THE THREE | | | INCH STACK FBC/ PLUMBING 708.3.4 | | | | | | 2 NEED DETAIL ON TUB DRAIN CONNECTION INSIDE SHOWER PAN | | | AREA. CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC | | | 2010107.2.1 | | | | | | | | | 3 NEED TO HAVE A VENT FOR THE W/M DISCHARGE FBC | | | PLUMBING 901.2.1 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-03-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-03-03 |
Time |
17:18 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-03-02 |
Time |
17:07 |
Sent To |
|
|
| Notes |
| 2016-03-03 13:48:12 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE PLANS INCLUDING THE ENGINEER'S SEAL AND | | | SIGNATURE HAVE BEEN PHOTO COPIED AND REDUCED IN SIZE. | | | SOME OF THE PRINT IS SO SMALL THAT IT IS ILLEGIBLE. FBC | | | 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS | | | SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON | | | SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. | | | THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, | | | SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO | | | RECORDS MANAGEMENT. | | | | | | 2) THE ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE IS | | | REQUIRED ON THE PLANS PER FAC 61G15-23.002. THE | | | ENGINEER'S SEAL SHALL BE A MINIMUM OF 1 7/8 INCHES IN | | | DIAMETER PER FAC61G15-23.001. | | | | | | 3) THE PROJECT IS LOCATED WITHIN 600 FEET OF THE | | | INTER-COASTAL WATERWAY. SURFACE ROUGHNESS D PREVAILS IN | | | THE UPWIND DIRECTION FOR AT LEAST 5,000 FEET. | | | THEREFORE, THIS PROJECT IS CONSIDERED TO BE EXPOSURE | | | CATEGORY D. FBC-R301.2.1.4.3 | | | | | | 4) REVIEW THE COMPONENT AND CLADDING WIND PRESSURES FOR | | | EXPOSURE D AND REVISE AS REQUIRED. FBC-R301.2.1 | | | | | | 5) PROVIDE AN EVALUATION REPORT FROM A FLORIDA LICENSED | | | ENGINEER THAT SPECIFIES THAT THE EXISTING GARAGE | | | FOUNDATION IS CAPABLE OF SUPPORTING THE SECOND STORY | | | ADDITION. FBC 107.2.1 | | | | | | 6) THE WINDOWS OF THE PROPOSED SECOND FLOOR BEDROOM | | | ABOVE THE EXISTING LIVING ROOM ARE REQUIRED TO COMPLY | | | WITH FBC-R310 FOR EMERGENCY ESCAPE AND RESCUE, | | | | | | 7) PROVIDE A DETAIL OR WALL SECTION THAT SHOWS HOW THE | | | NEW FLOOR TRUSSES FOR THE PROPOSED BEDROOM OVER THE | | | EXISTING LIVING ROOM WILL BE ATTACHED TO THE EXTERIOR | | | AND INTERIOR WALLS. FBC 107.2.1 | | | | | | 8) PROVIDE STRUCTURAL DETAILS OF THE MASTER BEDROOM | | | BALCONY AND GUARDRAIL. FBC-R301.1, R501.2 & R312 | | | | | | 9) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS | | | FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3 | | | THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD. PROVIDE TWO COMPLETE PRODUCT | | | APPROVALS WITH FL OR NOA NUMBERS INCLUDING INSTALLATION | | | INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES FOR EACH OF | | | THE DIFFERENT ROOFING MATERIALS, WINDOW/GLASS TYPES, | | | STRUCTURAL MULLIONS AND EXTERIOR DOOR TYPES. NO PRODUCT | | | APPROVALS WERE SUBMITTED FOR THE EXTERIOR FRENCH DOORS, | | | THE FRONT DOOR, THE FIXED WINDOWS AND STRUCTURAL | | | MULLIONS. | | | | | | 10) THE DRAWINGS FOR THE SINGLE HUNG WINDOWS (NOA NO. | | | 15-0512.10) ARE MISSING INFORMATION. IT APPEARS THAT | | | THE DRAWINGS WERE NOT SHRUNK TO FIT ON THE SMALLER | | | PAPER WHEN THEY WERE PRINTED. FBC 107.2.1 | | | | | | 11) SPECIFY THE METHOD OF ATTACHMENT THAT WILL BE USED | | | TO INSTALL THE CEMENT ROOF TILES (NOA NO. 15-0223.18) | | | AND RESIST THE REQUIRED OVERTURN MOMENT. IF A ROOF TILE | | | ADHESIVE WILL BE USED PROVIDE TWO COPIES OF THE PRODUCT | | | APPROVALS FOR IT. | | | | | | 12) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT | | | A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW | | | COMMENTS HAS BEEN ADDRESSED. | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-04-27 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-04-27 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-04-27 |
Time |
10:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2016-02-25 |
|
|
Cont ID |
|
| Sent By |
rlecky |
Date |
2016-02-25 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
rlecky |
Date |
2016-02-25 |
Time |
12:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
4 |
Status |
P |
Date |
2016-08-10 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2016-08-10 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2016-08-10 |
Time |
10:26 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
3 |
Status |
P |
Date |
2016-07-07 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2016-07-07 |
Time |
10:19 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2016-07-07 |
Time |
10:19 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-05-09 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2016-05-09 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2016-05-09 |
Time |
08:14 |
Sent To |
|
|
| Notes |
| 2016-05-09 08:14:47 | APPROVED BY HISTORIC PRESERVATION BOARD - 12/07/2015 - | | | DLE |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2016-03-07 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2016-03-07 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2016-03-07 |
Time |
16:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2016-08-10 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-08-10 |
Time |
10:35 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-07-29 |
Time |
11:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-07-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-07-13 |
Time |
18:03 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-06-21 |
Time |
10:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-05-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-05-19 |
Time |
18:39 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-04-20 |
Time |
13:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-03-08 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2016-03-08 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2016-02-04 |
Time |
09:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
P |
Date |
2016-08-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-08-09 |
Time |
17:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-08-09 |
Time |
17:16 |
Sent To |
|
|
| Notes |
| 2016-08-09 17:29:04 | MU 2016 - 18843 , NO FEES WE DUE. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2016-07-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-07-13 |
Time |
17:50 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-07-13 |
Time |
17:50 |
Sent To |
|
|
| Notes |
| 2016-07-13 17:50:51 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2016-05-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-05-19 |
Time |
17:35 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-05-19 |
Time |
17:35 |
Sent To |
|
|
| Notes |
| 2016-05-19 17:35:39 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2016-03-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-03-03 |
Time |
14:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-03-03 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2016-03-03 14:58:33 | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2016-08-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-08-10 |
Time |
07:18 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-08-09 |
Time |
18:19 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2016-07-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-07-13 |
Time |
17:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-07-13 |
Time |
14:56 |
Sent To |
|
|
| Notes |
| 2016-07-13 18:02:54 | PLAN | | | REVIEW COMMENTS | | | | | | 3RD REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY MECHANICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SPECIFY THE DUCT AND GRILL SIZES ON THE PLANS. FBC | | | 107.2.1 | | | | | | 2) SHOW COMPLIANCE WITH FBCR-M1602.4 FOR BALANCED | | | RETURN AIR ON THE PLANS. SPECIFY THE SIZES OF THE | | | TRANSFER DUCTS AND THEIR GRILLS ON THE MECHANICAL | | | PLANS. FBC 107.2.1.3 | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2016-05-19 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-05-19 |
Time |
17:32 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-05-19 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2016-05-19 17:32:48 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY MECHANICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE ENERGY COMPLIANCE FORMS ARE REQUIRED TO BE | | | SIGNED AND DATED BY THE OWNER OR AUTHORIZED AGENT | | | LEGALLY DESIGNATED BY THE OWNER. FBC ENERGY | | | CONSERVATION R103.1.1.2 | | | | | | 2) SPECIFY THE DUCT AND GRILL SIZES ON THE PLANS. FBC | | | 107.2.1 | | | | | | 3) PROVIDE AN EQUIPMENT SCHEDULE ON THE PLANS THAT | | | MATCHES THE SIZING CALCULATIONS. FBCR-M1401.3 | | | | | | 4) SHOW COMPLIANCE WITH FBCR-M1602.4 FOR BALANCED | | | RETURN AIR ON THE PLANS. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-03-02 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-03-02 |
Time |
17:06 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-03-02 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2016-03-02 17:42:48 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY MECHANICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SUBMIT TWO SETS OF ENERGY COMPLIANCE FORMS AND | | | EQUIPMENT SIZING CALCULATIONS FOR THE PROJECT. FBC | | | ENERGY CONSERVATION R101.5.1.1 AND FBCR-M1401.3 | | | | | | 2) SPECIFY THE DUCT AND GRILL SIZES ON THE PLANS. FBC | | | 107.2.1 | | | | | | 3) PROVIDE AN EQUIPMENT SCHEDULE ON THE PLANS THAT | | | MATCHES THE SIZING CALCULATIONS. FBCR-M1401.3 | | | | | | 4) SHOW COMPLIANCE WITH FBCR-M1602.4 FOR BALANCED | | | RETURN AIR ON THE PLANS. | | | | | | 5) THE PLANS ARE REQUIRED TO HAVE THE ORIGINAL | | | HANDWRITTEN SIGNATURE AND SEAL OF THE ENGINEER. COPIES | | | AND OTHER FACSIMILES ARE NOT ACCEPTABLE. FS471 & FAC | | | 61G15-23.002 | | | | | | 6) THE PLANS ARE REQUIRED TO BE DRAWN TO A MINIMUM 1/8 | | | INCH SCALE PER FBC 107.2.1.4. | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2016-08-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-08-09 |
Time |
18:53 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-08-09 |
Time |
18:53 |
Sent To |
|
|
| Notes |
| 2016-08-09 18:37:55 | PLUMBING PROVISO | | | APPROVED WITH EXCEPTIONS | | | PROVIDE MANUFACTURER'S SPECS. AND INSTALLATION | | | INSTRUCTIONS FOR FREE STANDING BATH TUB DRAIN | | | CONNECTION INSIDE OF SHOWER IN THE MASTER BATHROOM. | | | REQUIRED FOR ROUGH INSPECTION ! | | | REVISED RISER DIAGRAM WITH CORRECTIONS IS REQUIRED TO | | | BE SUBMITTED AND APPROVED PRIOR TO FINAL PLUMBING | | | INSPECTION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2016-06-24 |
|
|
Cont ID |
|
| Sent By |
gearl |
Date |
2016-06-24 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
gearl |
Date |
2016-06-24 |
Time |
09:32 |
Sent To |
|
|
| Notes |
| 2016-06-24 09:32:47 | NEED VENT BETWEEN W/C AND SHOWER AT NEW SECOND FLOOR | | | BATHROOM , NEED TO SHOW CLEAN OUT ON BASE OF STACK , | | | DRAWING SHOW STUDOR VENT AND VTR NEED TO KNOW WHICH IS | | | BEING USED | | 2016-06-24 09:23:11 | PROVIDE MANUFACTURE SPEC'S AND INSTALLATION INSTRUCTION | | | FOR MASTER BATH TUB AT ROUGH INSPECTION |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2016-05-12 |
|
|
Cont ID |
|
| Sent By |
gearl |
Date |
2016-05-12 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-05-12 |
Time |
12:08 |
Sent To |
|
|
| Notes |
| 2016-05-12 12:42:47 | | | | | | | | | | PLUMBING PROVISO | | | | | | 1. PROVIDE MANUFACTURE SPECS AND INSTALLATION | | | INSTRUCTIONS FOR MASTER BATH TUB DRAIN CONNECTION | | | INSIDE SHOWER, REQUIRED FOR ROUGH INSPECTION !! | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | 2016-05-03 13:26:58 | | | | | | | | | | | | | | | | 1. NEED CO AT BASE OF STACK ( 3 " ) FBC PLUMBING | | | SECTION 708.3.4 | | | | | | 2. NEED DETAIL ON TUB DRAIN CONNECTION IN THE TUB AREA | | | | | | | | | 3. NEED TO HAVE A VENT ON THE W/M DRAIN FBC PLUMBING | | | SECTION 901.2.1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-02-23 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-02-18 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-02-18 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2016-02-18 11:33:43 | 1ST REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1.PLANS ARE TO SMALL TO READ CLEARLY PROVIDE A SET OF | | | PLANS THAT COMPLY WITH WPB AMEND. TO FBC SEC. 107.2.1.4 | | | QUALITY OF BUILDING PLANS. BUILDING PLANS SHALL BE | | | DRAWN TO A MINIMUM 1/8 INCH | | | SCALE UPON SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE | | | MEDIUM. THE BUILDING OFFICIAL MAY | | | ESTABLISH THROUGH DEPARTMENTAL POLICY, OTHER STANDARDS | | | FOR PLANS AND SPECIFICATIONS, IN | | | ORDER TO PROVIDE CONFORMITY TO ITS RECORD RETENTION | | | PROGRAM. THIS POLICY MAY INCLUDE SUCH | | | THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR | | | OTHER ITEMS RELATED TO RECORDS | | | MANAGEMENT. ELECTRONIC MEDIA MUST BE COMPATIBLE WITH | | | THE ARCHIVE REQUIREMENTS OF | | | FLORIDA STATUTES. | | | | | | 2. ENGINEERS SEAL AND SIGNATURE CAN NOT BE A COPY SHALL | | | COMPLY WITH FL AMEND. CODE 61G15-23.001(1) | | | | | | 3. PLEASE PROVIDE A CLEAR SCOPE OF WORK FOR PLUMBING | | | WHAT IS EXISTING TO REMAIN AND WHAT IS NEW. | | | PER WPB AMEND. TO FBC SEC. 107.2.1.3 | | | | | | DO TO THE PLANS BEING UNCLEAR A COMPLETE AND | | | COMPREHENSIVE REVIEW CAN NOT BE DONE AT THIS TIME | | | ADDITIONAL COMMENT MAY BE GENERATED ON 2ND REVIEW. |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2016-08-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2016-08-10 |
Time |
07:12 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2016-08-10 |
Time |
07:12 |
Sent To |
|
|
| Notes |
| 2016-08-10 07:18:11 | TAMKO ASPHALT SHINGLES, NOA NO.11-1228.01 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2016-08-10 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2016-08-10 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2016-08-10 |
Time |
10:27 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2016-07-07 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2016-07-07 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2016-07-07 |
Time |
15:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2016-05-09 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2016-05-09 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2016-05-09 |
Time |
08:16 |
Sent To |
|
|
| Notes |
| 2016-05-09 08:17:26 | CURRENT SITE SURVEY INCLUDED, MEETS FAR AND LOT | | | COVERAGE REQUIREMENTS PER THE LDR - DLE |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2016-03-07 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2016-03-07 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2016-03-07 |
Time |
16:14 |
Sent To |
|
|
| Notes |
| 2016-03-07 16:16:24 | NEED TWO CURRENT SURVEYS. |
|
|