Plan Review Details - Permit 16020175
Plan Review Stops For Permit 16020175
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2016-08-09 Cont ID  
Sent By rmcdouga Date 2016-08-09 Time 18:20 Rev Time 0.00
Received By rmcdouga Date 2016-08-09 Time 18:20 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-07-13 Cont ID  
Sent By rmcdouga Date 2016-07-13 Time 17:49 Rev Time 0.00
Received By rmcdouga Date 2016-07-13 Time 14:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-05-19 Cont ID  
Sent By gearl Date 2016-05-19 Time 18:40 Rev Time 0.00
Received By rmcdouga Date 2016-05-19 Time 13:45 Sent To  
Notes
2016-05-19 18:38:57PLAN
 REVIEW COMMENTS
  
 2ND REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE PROJECT IS LOCATED WITHIN 600 FEET OF THE
 INTER-COASTAL WATERWAY. SURFACE ROUGHNESS D PREVAILS IN
 THE UPWIND DIRECTION FOR AT LEAST 5,000 FEET.
 THEREFORE, THIS PROJECT IS CONSIDERED TO BE EXPOSURE
 CATEGORY D. FBC-R301.2.1.4.3 THE EXPOSURE CATEGORY HAS
 NOT BEEN CHANGED ON THE PLANS.
  
 2) REVIEW THE COMPONENT AND CLADDING WIND PRESSURES FOR
 EXPOSURE D AND REVISE AS REQUIRED. FBC-R301.2.1 THE
 COMPONENT AND CLADDING WIND PRESSURES HAVE NOT BEEN
 CHANGED ON THE PLANS.
  
 3) THE WINDOWS OF THE PROPOSED SECOND FLOOR BEDROOM
 ABOVE THE EXISTING LIVING ROOM ARE REQUIRED TO COMPLY
 WITH FBC-R310 FOR EMERGENCY ESCAPE AND RESCUE, THIS IS
 NOT INDICATED ON THE PLANS.
  
 4) PROVIDE DETAILS OF THE GUARDRAIL FOR THE MASTER
 BEDROOM BALCONY. FBC-R312
  
 5) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS
 FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3
 THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD. PROVIDE TWO COMPLETE PRODUCT
 APPROVALS WITH FL OR NOA NUMBERS INCLUDING INSTALLATION
 INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES FOR EACH OF
 THE DIFFERENT ROOFING MATERIALS, WINDOW/GLASS TYPES,
 STRUCTURAL MULLIONS AND EXTERIOR DOOR TYPES. NO PRODUCT
 APPROVALS WERE SUBMITTED FOR THE STRUCTURAL MULLIONS.
  
 6) THE PLANS SPECIFY CEMENT ROOF TILES AND PRODUCT
 APPROVALS FOR TAMKO ASPHALT ASPHALT SHINGLES (NOA NO.
 11-1228.01) WERE SUBMITTED. THE PLANS WILL NEED TO BE
 REVISED AND THE ASPHALT SHINGLES WILL NEED TO BE
 APPROVED BY THE HISTORIC PLANNER.
  
 7) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT A
 RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW
 COMMENTS HAS BEEN ADDRESSED.
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
2016-05-12 09:12:055/3/16 REVIEW COMMENTS DO NOT APPLY, PLEASE DISREGARD.
2016-05-03 13:14:25 
  
  
 1. NEED TO HAVE A CLEAN OUT AT THE BASE OF THE THREE
 INCH STACK FBC/ PLUMBING 708.3.4
  
 2 NEED DETAIL ON TUB DRAIN CONNECTION INSIDE SHOWER PAN
 AREA. CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC
 2010107.2.1
  
  
 3 NEED TO HAVE A VENT FOR THE W/M DISCHARGE FBC
 PLUMBING 901.2.1

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-03-03 Cont ID  
Sent By rmcdouga Date 2016-03-03 Time 17:18 Rev Time 0.00
Received By rmcdouga Date 2016-03-02 Time 17:07 Sent To  
Notes
2016-03-03 13:48:12PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE PLANS INCLUDING THE ENGINEER'S SEAL AND
 SIGNATURE HAVE BEEN PHOTO COPIED AND REDUCED IN SIZE.
 SOME OF THE PRINT IS SO SMALL THAT IT IS ILLEGIBLE. FBC
 107.2.1.4 QUALITY OF BUILDING PLANS. BUILDING PLANS
 SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON
 SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM.
 THIS POLICY MAY INCLUDE SUCH THINGS AS MINIMUM SIZE,
 SHAPE, CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO
 RECORDS MANAGEMENT.
  
 2) THE ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE IS
 REQUIRED ON THE PLANS PER FAC 61G15-23.002. THE
 ENGINEER'S SEAL SHALL BE A MINIMUM OF 1 7/8 INCHES IN
 DIAMETER PER FAC61G15-23.001.
  
 3) THE PROJECT IS LOCATED WITHIN 600 FEET OF THE
 INTER-COASTAL WATERWAY. SURFACE ROUGHNESS D PREVAILS IN
 THE UPWIND DIRECTION FOR AT LEAST 5,000 FEET.
 THEREFORE, THIS PROJECT IS CONSIDERED TO BE EXPOSURE
 CATEGORY D. FBC-R301.2.1.4.3
  
 4) REVIEW THE COMPONENT AND CLADDING WIND PRESSURES FOR
 EXPOSURE D AND REVISE AS REQUIRED. FBC-R301.2.1
  
 5) PROVIDE AN EVALUATION REPORT FROM A FLORIDA LICENSED
 ENGINEER THAT SPECIFIES THAT THE EXISTING GARAGE
 FOUNDATION IS CAPABLE OF SUPPORTING THE SECOND STORY
 ADDITION. FBC 107.2.1
  
 6) THE WINDOWS OF THE PROPOSED SECOND FLOOR BEDROOM
 ABOVE THE EXISTING LIVING ROOM ARE REQUIRED TO COMPLY
 WITH FBC-R310 FOR EMERGENCY ESCAPE AND RESCUE,
  
 7) PROVIDE A DETAIL OR WALL SECTION THAT SHOWS HOW THE
 NEW FLOOR TRUSSES FOR THE PROPOSED BEDROOM OVER THE
 EXISTING LIVING ROOM WILL BE ATTACHED TO THE EXTERIOR
 AND INTERIOR WALLS. FBC 107.2.1
  
 8) PROVIDE STRUCTURAL DETAILS OF THE MASTER BEDROOM
 BALCONY AND GUARDRAIL. FBC-R301.1, R501.2 & R312
  
 9) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS
 FOR THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9N-3
 THAT HAVE BEEN REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD. PROVIDE TWO COMPLETE PRODUCT
 APPROVALS WITH FL OR NOA NUMBERS INCLUDING INSTALLATION
 INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES FOR EACH OF
 THE DIFFERENT ROOFING MATERIALS, WINDOW/GLASS TYPES,
 STRUCTURAL MULLIONS AND EXTERIOR DOOR TYPES. NO PRODUCT
 APPROVALS WERE SUBMITTED FOR THE EXTERIOR FRENCH DOORS,
 THE FRONT DOOR, THE FIXED WINDOWS AND STRUCTURAL
 MULLIONS.
  
 10) THE DRAWINGS FOR THE SINGLE HUNG WINDOWS (NOA NO.
 15-0512.10) ARE MISSING INFORMATION. IT APPEARS THAT
 THE DRAWINGS WERE NOT SHRUNK TO FIT ON THE SMALLER
 PAPER WHEN THEY WERE PRINTED. FBC 107.2.1
  
 11) SPECIFY THE METHOD OF ATTACHMENT THAT WILL BE USED
 TO INSTALL THE CEMENT ROOF TILES (NOA NO. 15-0223.18)
 AND RESIST THE REQUIRED OVERTURN MOMENT. IF A ROOF TILE
 ADHESIVE WILL BE USED PROVIDE TWO COPIES OF THE PRODUCT
 APPROVALS FOR IT.
  
 12) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT
 A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW
 COMMENTS HAS BEEN ADDRESSED.
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-04-27 Cont ID  
Sent By vperez Date 2016-04-27 Time 11:23 Rev Time 0.00
Received By vperez Date 2016-04-27 Time 10:48 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-02-25 Cont ID  
Sent By rlecky Date 2016-02-25 Time 14:35 Rev Time 0.00
Received By rlecky Date 2016-02-25 Time 12:57 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 4 Status P Date 2016-08-10 Cont ID  
Sent By destabro Date 2016-08-10 Time 10:26 Rev Time 0.00
Received By destabro Date 2016-08-10 Time 10:26 Sent To B
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 3 Status P Date 2016-07-07 Cont ID  
Sent By destabro Date 2016-07-07 Time 10:19 Rev Time 0.00
Received By destabro Date 2016-07-07 Time 10:19 Sent To B
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2016-05-09 Cont ID  
Sent By destabro Date 2016-05-09 Time 08:14 Rev Time 0.00
Received By destabro Date 2016-05-09 Time 08:14 Sent To  
Notes
2016-05-09 08:14:47APPROVED BY HISTORIC PRESERVATION BOARD - 12/07/2015 -
 DLE

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2016-03-07 Cont ID  
Sent By fmittner Date 2016-03-07 Time 16:14 Rev Time 0.00
Received By fmittner Date 2016-03-07 Time 16:14 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2016-08-10 Cont ID  
Sent By skennedy Date 2016-08-10 Time 10:35 Rev Time 0.00
Received By skennedy Date 2016-07-29 Time 11:33 Sent To  
Notes
2016-07-29 11:33:08R16

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-07-13 Cont ID  
Sent By rmcdouga Date 2016-07-13 Time 18:03 Rev Time 0.00
Received By rmcdouga Date 2016-06-21 Time 10:23 Sent To  
Notes
2016-06-21 10:23:36R31

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-05-19 Cont ID  
Sent By rmcdouga Date 2016-05-19 Time 18:39 Rev Time 0.00
Received By rmcdouga Date 2016-04-20 Time 13:37 Sent To  
Notes
2016-04-20 13:38:02R20

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-03-08 Cont ID  
Sent By cpuell Date 2016-03-08 Time 09:31 Rev Time 0.00
Received By cpuell Date 2016-02-04 Time 09:46 Sent To  
Notes
2016-02-05 09:46:43R04

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status P Date 2016-08-09 Cont ID  
Sent By rmcdouga Date 2016-08-09 Time 17:16 Rev Time 0.00
Received By rmcdouga Date 2016-08-09 Time 17:16 Sent To  
Notes
2016-08-09 17:29:04MU 2016 - 18843 , NO FEES WE DUE.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2016-07-13 Cont ID  
Sent By rmcdouga Date 2016-07-13 Time 17:50 Rev Time 0.00
Received By rmcdouga Date 2016-07-13 Time 17:50 Sent To  
Notes
2016-07-13 17:50:51BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2016-05-19 Cont ID  
Sent By rmcdouga Date 2016-05-19 Time 17:35 Rev Time 0.00
Received By rmcdouga Date 2016-05-19 Time 17:35 Sent To  
Notes
2016-05-19 17:35:39BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2016-03-03 Cont ID  
Sent By rmcdouga Date 2016-03-03 Time 14:57 Rev Time 0.00
Received By rmcdouga Date 2016-03-03 Time 14:57 Sent To  
Notes
2016-03-03 14:58:33BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2016-08-10 Cont ID  
Sent By rmcdouga Date 2016-08-10 Time 07:18 Rev Time 0.00
Received By rmcdouga Date 2016-08-09 Time 18:19 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2016-07-13 Cont ID  
Sent By rmcdouga Date 2016-07-13 Time 17:51 Rev Time 0.00
Received By rmcdouga Date 2016-07-13 Time 14:56 Sent To  
Notes
2016-07-13 18:02:54PLAN
 REVIEW COMMENTS
  
 3RD REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY MECHANICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SPECIFY THE DUCT AND GRILL SIZES ON THE PLANS. FBC
 107.2.1
  
 2) SHOW COMPLIANCE WITH FBCR-M1602.4 FOR BALANCED
 RETURN AIR ON THE PLANS. SPECIFY THE SIZES OF THE
 TRANSFER DUCTS AND THEIR GRILLS ON THE MECHANICAL
 PLANS. FBC 107.2.1.3
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2016-05-19 Cont ID  
Sent By rmcdouga Date 2016-05-19 Time 17:32 Rev Time 0.00
Received By rmcdouga Date 2016-05-19 Time 13:45 Sent To  
Notes
2016-05-19 17:32:48PLAN
 REVIEW COMMENTS
  
 2ND REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY MECHANICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE ENERGY COMPLIANCE FORMS ARE REQUIRED TO BE
 SIGNED AND DATED BY THE OWNER OR AUTHORIZED AGENT
 LEGALLY DESIGNATED BY THE OWNER. FBC ENERGY
 CONSERVATION R103.1.1.2
  
 2) SPECIFY THE DUCT AND GRILL SIZES ON THE PLANS. FBC
 107.2.1
  
 3) PROVIDE AN EQUIPMENT SCHEDULE ON THE PLANS THAT
 MATCHES THE SIZING CALCULATIONS. FBCR-M1401.3
  
 4) SHOW COMPLIANCE WITH FBCR-M1602.4 FOR BALANCED
 RETURN AIR ON THE PLANS.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-03-02 Cont ID  
Sent By rmcdouga Date 2016-03-02 Time 17:06 Rev Time 0.00
Received By rmcdouga Date 2016-03-02 Time 16:10 Sent To  
Notes
2016-03-02 17:42:48PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY MECHANICAL
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) SUBMIT TWO SETS OF ENERGY COMPLIANCE FORMS AND
 EQUIPMENT SIZING CALCULATIONS FOR THE PROJECT. FBC
 ENERGY CONSERVATION R101.5.1.1 AND FBCR-M1401.3
  
 2) SPECIFY THE DUCT AND GRILL SIZES ON THE PLANS. FBC
 107.2.1
  
 3) PROVIDE AN EQUIPMENT SCHEDULE ON THE PLANS THAT
 MATCHES THE SIZING CALCULATIONS. FBCR-M1401.3
  
 4) SHOW COMPLIANCE WITH FBCR-M1602.4 FOR BALANCED
 RETURN AIR ON THE PLANS.
  
 5) THE PLANS ARE REQUIRED TO HAVE THE ORIGINAL
 HANDWRITTEN SIGNATURE AND SEAL OF THE ENGINEER. COPIES
 AND OTHER FACSIMILES ARE NOT ACCEPTABLE. FS471 & FAC
 61G15-23.002
  
 6) THE PLANS ARE REQUIRED TO BE DRAWN TO A MINIMUM 1/8
 INCH SCALE PER FBC 107.2.1.4.
  
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2016-08-09 Cont ID  
Sent By rmcdouga Date 2016-08-09 Time 18:53 Rev Time 0.00
Received By rmcdouga Date 2016-08-09 Time 18:53 Sent To  
Notes
2016-08-09 18:37:55PLUMBING PROVISO
 APPROVED WITH EXCEPTIONS
 PROVIDE MANUFACTURER'S SPECS. AND INSTALLATION
 INSTRUCTIONS FOR FREE STANDING BATH TUB DRAIN
 CONNECTION INSIDE OF SHOWER IN THE MASTER BATHROOM.
 REQUIRED FOR ROUGH INSPECTION !
 REVISED RISER DIAGRAM WITH CORRECTIONS IS REQUIRED TO
 BE SUBMITTED AND APPROVED PRIOR TO FINAL PLUMBING
 INSPECTION.

Review Stop P PLUMBING
Rev No 3 Status F Date 2016-06-24 Cont ID  
Sent By gearl Date 2016-06-24 Time 09:23 Rev Time 0.00
Received By gearl Date 2016-06-24 Time 09:32 Sent To  
Notes
2016-06-24 09:32:47NEED VENT BETWEEN W/C AND SHOWER AT NEW SECOND FLOOR
 BATHROOM , NEED TO SHOW CLEAN OUT ON BASE OF STACK ,
 DRAWING SHOW STUDOR VENT AND VTR NEED TO KNOW WHICH IS
 BEING USED
2016-06-24 09:23:11PROVIDE MANUFACTURE SPEC'S AND INSTALLATION INSTRUCTION
 FOR MASTER BATH TUB AT ROUGH INSPECTION

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-05-12 Cont ID  
Sent By gearl Date 2016-05-12 Time 12:43 Rev Time 0.00
Received By gjohnson Date 2016-05-12 Time 12:08 Sent To  
Notes
2016-05-12 12:42:47 
  
  
 PLUMBING PROVISO
  
 1. PROVIDE MANUFACTURE SPECS AND INSTALLATION
 INSTRUCTIONS FOR MASTER BATH TUB DRAIN CONNECTION
 INSIDE SHOWER, REQUIRED FOR ROUGH INSPECTION !!
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  
2016-05-03 13:26:58 
  
  
  
  
 1. NEED CO AT BASE OF STACK ( 3 " ) FBC PLUMBING
 SECTION 708.3.4
  
 2. NEED DETAIL ON TUB DRAIN CONNECTION IN THE TUB AREA
  
  
 3. NEED TO HAVE A VENT ON THE W/M DRAIN FBC PLUMBING
 SECTION 901.2.1

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-02-23 Cont ID  
Sent By gjohnson Date 2016-02-18 Time 14:52 Rev Time 0.00
Received By gjohnson Date 2016-02-18 Time 11:22 Sent To  
Notes
2016-02-18 11:33:431ST REVIEW: FBC 2014
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1.PLANS ARE TO SMALL TO READ CLEARLY PROVIDE A SET OF
 PLANS THAT COMPLY WITH WPB AMEND. TO FBC SEC. 107.2.1.4
 QUALITY OF BUILDING PLANS. BUILDING PLANS SHALL BE
 DRAWN TO A MINIMUM 1/8 INCH
 SCALE UPON SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE
 MEDIUM. THE BUILDING OFFICIAL MAY
 ESTABLISH THROUGH DEPARTMENTAL POLICY, OTHER STANDARDS
 FOR PLANS AND SPECIFICATIONS, IN
 ORDER TO PROVIDE CONFORMITY TO ITS RECORD RETENTION
 PROGRAM. THIS POLICY MAY INCLUDE SUCH
 THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR
 OTHER ITEMS RELATED TO RECORDS
 MANAGEMENT. ELECTRONIC MEDIA MUST BE COMPATIBLE WITH
 THE ARCHIVE REQUIREMENTS OF
 FLORIDA STATUTES.
  
 2. ENGINEERS SEAL AND SIGNATURE CAN NOT BE A COPY SHALL
 COMPLY WITH FL AMEND. CODE 61G15-23.001(1)
  
 3. PLEASE PROVIDE A CLEAR SCOPE OF WORK FOR PLUMBING
 WHAT IS EXISTING TO REMAIN AND WHAT IS NEW.
 PER WPB AMEND. TO FBC SEC. 107.2.1.3
  
 DO TO THE PLANS BEING UNCLEAR A COMPLETE AND
 COMPREHENSIVE REVIEW CAN NOT BE DONE AT THIS TIME
 ADDITIONAL COMMENT MAY BE GENERATED ON 2ND REVIEW.

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2016-08-10 Cont ID  
Sent By rmcdouga Date 2016-08-10 Time 07:12 Rev Time 0.00
Received By rmcdouga Date 2016-08-10 Time 07:12 Sent To  
Notes
2016-08-10 07:18:11TAMKO ASPHALT SHINGLES, NOA NO.11-1228.01

Review Stop Z ZONING
Rev No 4 Status P Date 2016-08-10 Cont ID  
Sent By destabro Date 2016-08-10 Time 10:27 Rev Time 0.00
Received By destabro Date 2016-08-10 Time 10:27 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2016-07-07 Cont ID  
Sent By destabro Date 2016-07-07 Time 15:59 Rev Time 0.00
Received By destabro Date 2016-07-07 Time 15:59 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2016-05-09 Cont ID  
Sent By destabro Date 2016-05-09 Time 08:16 Rev Time 0.00
Received By destabro Date 2016-05-09 Time 08:16 Sent To  
Notes
2016-05-09 08:17:26CURRENT SITE SURVEY INCLUDED, MEETS FAR AND LOT
 COVERAGE REQUIREMENTS PER THE LDR - DLE

Review Stop Z ZONING
Rev No 1 Status F Date 2016-03-07 Cont ID  
Sent By fmittner Date 2016-03-07 Time 16:14 Rev Time 0.00
Received By fmittner Date 2016-03-07 Time 16:14 Sent To  
Notes
2016-03-07 16:16:24NEED TWO CURRENT SURVEYS.