Plan Review Details - Permit 16010985
Plan Review Stops For Permit 16010985
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-09-15 Cont ID  
Sent By cthroop Date 2016-09-15 Time 14:49 Rev Time 0.00
Received By cthroop Date 2016-09-15 Time 14:46 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-07-11 Cont ID  
Sent By cthroop Date 2016-07-11 Time 11:53 Rev Time 0.00
Received By cthroop Date 2016-07-11 Time 11:53 Sent To  
Notes
2016-07-11 11:53:59COMPLY WITH ZONING AND ENGINEERING COMMENTS AND
 RE-SUBMIT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2016-03-04 Cont ID  
Sent By cthroop Date 2016-03-04 Time 10:40 Rev Time 0.00
Received By cthroop Date 2016-03-04 Time 10:40 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 4 Status P Date 2016-09-15 Cont ID  
Sent By Mgonzale Date 2016-09-15 Time   Rev Time 1.00
Received By mgonzale Date 2016-09-15 Time   Sent To I
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 3 Status F Date 2016-07-08 Cont ID  
Sent By mGONZALE Date 2016-07-08 Time   Rev Time 0.25
Received By mgonzale Date 2016-07-08 Time   Sent To B
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2016-05-02 Cont ID  
Sent By Mgonzale Date 2016-05-02 Time   Rev Time 0.50
Received By mgonzale Date 2016-05-02 Time   Sent To I
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2016-02-25 Cont ID  
Sent By Mgonzale Date 2016-02-25 Time   Rev Time 1.00
Received By mgonzale Date 2016-02-25 Time   Sent To B
Notes
2016-02-25 10:20:37PLEASE ADDRESS PLANNING COMMENTS. ENG WILL REVIEW AT
 RESUBMITTAL.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2016-09-15 Cont ID  
Sent By cthroop Date 2016-09-15 Time 14:46 Rev Time 0.00
Received By cthroop Date 2016-08-02 Time 09:57 Sent To  
Notes
2016-08-03 09:58:16ROUTED TO ZONING

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-07-11 Cont ID  
Sent By cthroop Date 2016-07-11 Time 11:53 Rev Time 0.00
Received By cthroop Date 2016-06-21 Time 15:31 Sent To Z
Notes
2016-07-11 07:23:247/11 TO CT DESK
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-05-02 Cont ID  
Sent By cpuell Date 2016-05-02 Time 15:28 Rev Time 0.00
Received By cpuell Date 2016-04-28 Time 14:15 Sent To  
Notes
2016-04-28 14:15:34RESUB ROUTED TO LLOUIE VIA ZONING INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-03-04 Cont ID  
Sent By cthroop Date 2016-03-04 Time 10:40 Rev Time 0.00
Received By cthroop Date 2016-01-29 Time 10:23 Sent To Z
Notes
***NONE***

Review Stop Z ZONING
Rev No 4 Status P Date 2016-08-03 Cont ID  
Sent By llouie Date 2016-08-03 Time   Rev Time 0.00
Received By llouie Date 2016-08-03 Time   Sent To ENG
Notes
2016-08-03 16:39:04ZONING APPROVED WITH THE FOLLOWING PROVISOS:
  
 1.) AT LEAST ONE LADDER SHALL BE PROVIDED FOR THE DOCK,
 EXTENDING FROM THE DOCK SURFACE TO TWO FEET BELOW THE
 MEAN WATER LINE. [ZLDR S.94-314(A)(3)L.]
  
 2.) THE DOCK SHALL HAVE WATER RESISTANT REFLECTIVE
 NUMERALS CORRESPONDING TO THE STREET ADDRESS OF THE
 UPLAND PROPERTY AND SHALL BE VISIBLE FROM THE WATERWAY.
 [ZLDR S.94-314(A)(3)O.]
  
 3.) SEPARATE PERMIT APPLICATION REQUIRED FOR A SECURITY
 FENCE.
  
 CONTACT LINDA LOUIE @ 561-822-1458 IF THERE ARE
 QUESTIONS.
  
  
  
  
  
  
  
2016-08-03 13:40:42ROUTED TO LINDA LOUIE

Review Stop Z ZONING
Rev No 3 Status F Date 2016-06-23 Cont ID  
Sent By cthroop Date 2016-07-11 Time 11:53 Rev Time 0.00
Received By llouie Date 2016-06-23 Time 14:17 Sent To ENG
Notes
2016-06-23 14:18:45** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) THE DOCK HAS SIGNIFICANTLY CHANGED SINCE THE
 ORIGINAL SUBMITTAL (1/29/2016). THE FOLLOWING FORMS
 NEED TO BE UPDATED TO REFLECT THE CHANGES TO THE
 PROPOSED DOCK:
  
 A.) CONSTRUCTION PLANS PREPARED BY AND UNDER THE SEAL
 OF A FLORIDA REGISTERED PROFESSIONAL ENGINEER. [ZLDR
 S.94-314(A)(2)B.]
  
 B.) CROSS SECTION SHOWING ALL ELEMENTS OF THE PROPOSED
 DOCK, THE BOTTOM OF THE WATERWAY, AS WELL AS THE MEAN
 HIGH WATERLINE AND MEAN LOW WATERLINE. [ZLDR
 S.94-314(A)(2)D.]
  
 C.) VALID WRITTEN APPROVAL OF THE PROPOSED DOCK BY THE
 FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION. SUCH
 WRITTEN APPROVAL SHALL CONTAIN THE DATE ON WHICH THE
 PROPOSED DOCK WAS APPROVED. [ZLDR S.94-314(A)(2)E.]
  
 2.) IS A SECURITY FENCE PROPOSED FOR THE DOCK? [ZLDR
 S.94-314(A)(4)]
  
 REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL
 COMMENTS. PLEASE CONTACT LINDA LOUIE @ (561) 822-1458
 IF THERE ARE QUESTIONS.
  

Review Stop Z ZONING
Rev No 2 Status F Date 2016-05-02 Cont ID  
Sent By llouie Date 2016-05-02 Time   Rev Time 0.00
Received By llouie Date 2016-05-02 Time   Sent To ENG
Notes
2016-05-02 12:47:40** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS IN WRITING OR ON
 THE PLANS WHERE APPLICABLE:
  
 1.) 2/2/16 REPEAT COMMENT: THE MAXIMUM WIDTH OF THE
 DOCK SHALL NOT EXCEED 10 FEET. FINGER PIERS AND
 TERMINAL PLATFORMS WHICH ARE GENERALLY PERPENDICULAR TO
 THE DOCK AND PARALLEL TO THE SEAWALL, BULKHEAD, OR
 RIPARIAN PROPERTY LINE, MAY BE GREATER THAN 10 FEET IN
 WIDTH (MEASURED PARALLEL TO THE DOCK) PROVIDED THAT
 THEY REMAIN WITHIN THE MIDDLE ONE-THIRD OF THE PROPERTY
 AND DO NOT EXCEED 10 FEET IN LENGTH (MEASURED
 PERPENDICULAR TO THE DOCK). [ZLDR S.94-314(A)(3)J.]
  
 2.) THE PROPOSED FLOATING KYAK DOCK IS CONSIDERED PART
 OF THE DOCK STRUCTURE AND DOES NOT COMPLY WITH THE
 REQUIREMENTS OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS (ZLDR) FOR DOCK CONSTRUCTION. PLEASE
 ADDRESS.
  
 REVISIONS TO THE PLANS MAY RESULT IN ADDITIONAL
 COMMENTS. PLEASE CONTACT LINDA LOUIE @ (561) 822-1458
 IF THERE ARE QUESTIONS.
  

Review Stop Z ZONING
Rev No 1 Status F Date 2016-02-02 Cont ID  
Sent By cthroop Date 2016-03-04 Time 10:40 Rev Time 0.00
Received By llouie Date 2016-02-02 Time 16:00 Sent To ENG
Notes
2016-02-02 16:01:37** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS IN WRITING AND/OR
 ON THE PLANS WHERE APPLICABLE:
  
 1.) AN UPDATED SIGNED AND SEALED SURVEY OF THE
 PROPERTY, PREPARED BY A FLORIDA LICENSED LAND SURVEYOR
 IS REQUIRED. THE SURVEY MUST ILLUSTRATE THE DIMENSIONS
 OF THE LOT AND ALL APPLICABLE SETBACKS OF THE LOT AS IT
 RELATES TO THE DOCK CONSTRUCTION (I.E. MIDDLE
 ONE-THIRD).
  
 2.) ALL PORTIONS OF THE DOCK, INCLUDING PILINGS,
 BOATLIFTS AND OTHER MOORING-RELATED FACILITIES SHALL BE
 CONSTRUCTED IN THE MIDDLE ONE-THIRD OF THE LOT ON WHICH
 THE DOCK IS CONSTRUCTED. PLEASE ILLUSTRATE THAT ALL
 PORTIONS OF THE DOCK IS PLACED IN THE MIDDLE ONE-THIRD
 OF THE LOT. [ZLDR S.94-314(A)(3)H.]
  
 3.) THE DOCK LENGTH SHALL BE MEASURED FROM THE MEAN
 HIGH WATERLINE OR THE BULKHEAD, TO THE FURTHEST POINT
 OF THE DOCK, FINGER PIER, OR TERMINAL PLATFORM. THE
 MAXIMUM DOCK LENGTH SHALL NOT EXCEED 100 FEET. [ZLDR
 S.94-314(A)(3)I.]
  
 4.) THE MAXIMUM WIDTH OF THE DOCK SHALL NOT EXCEED 10
 FEET. FINGER PIERS AND TERMINAL PLATFORMS WHICH ARE
 GENERALLY PERPENDICULAR TO THE DOCK AND PARALLEL TO THE
 SEAWALL, BULKHEAD, OR RIPARIAN PROPERTY LINE MAY BE
 GREATER THAN 10 FEET IN WIDTH (MEASURED PARALLEL TO THE
 DOCK) PROVIDED THAT THEY REMAIN WITHIN THE MIDDLE
 ONE-THIRD OF THE PROPERTY AND DO NOT EXCEED 10 FEET IN
 LENGTH (MEASURED PERPENDICULAR TO THE DOCK). [ZLDR
 S.94-314(A)(3)J.]
  
 5.) THE PLANS SUBMITTED TO DEP SHOWS A GAZEBO STRUCTURE
 AT THE END OF THE DOCK, WHICH IS NOT NOTED IN THE
 ENGINEERING DRAWINGS. PLEASE NOTE THAT PURSUANT TO
 SECTION 94-314(A)(3)K. OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS (ZLDR), NO STRUCTURES OR
 BUILDINGS SHALL BE CONSTRUCTED ON THE PROPOSED DOCK.
  
 6.) AT LEAST ONE LADDER SHALL BE PROVIDED FOR THE DOCK,
 EXTENDING FROM THE DOCK SURFACE TO 2 FEET BELOW THE
 MEAN WATER LINE. [ZLDR S.94-314(A)(3)L.]
  
 7.) WILL THERE BE A SECURITY FENCE TO PREVENT
 UNAUTHORIZED ENTRY TO THE DOCK? IF SO, THE SECURITY
 FENCE MAY BE CONSTRUCTED ON A DOCK TO CONSIST OF RAILS
 AND STILES WHICH DO NOT EXCEED ONE AND ONE-QUARTER
 INCHES IN CROSS SECTIONS AND WHICH ARE PLACED NO CLOSER
 THAN THREE AND NO FURTHER THAN FOUR INCHES ON CENTER.
 SECURITY FENCES MAY BE CONSTRUCTED OF ALUMINUM, WROUGHT
 IRON, STEEL, OR OTHER SIMILAR METAL. CHAIN LINK FENCING
 SHALL BE PROHIBITED. [ZLDR S.94-314(4)]
  
 PLEASE CALL LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
2016-02-02 10:47:372/2/16


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved