| 2016-01-22 16:04:12 | 1ST REVIEW: FBC 2014 BUILDING |
| | PERMIT #16010738 |
| | 01/22/16 |
| | |
| | 1) IN ACCORDANCE WITH SECTION 1609.4 FBC-14 BUILDING, |
| | THE HOUSE AND ROOF PROJECT IS LOCATED IN EXPOSURE D. |
| | PROVIDE CORRECTED CALCULATIONS AND AND SUBMITTALS |
| | INDICATING COMPLIANCE. PLEASE NOTE THAT THE PRODUCT |
| | APPROVALS ARE ISSUED WITH ENGINEERING CERTIFICATIONS, |
| | AND THE ENGINEER OF RECORD MAY PROVIDE A REVIEW |
| | SIGNATURE ON THE DOCUMENTS, BUT NOT RAISED SEALS AND |
| | SIGNATURES. |
| | 2) PLEASE SEE NOTE 5.5.1 ON PAGE 3 OF THE ENTEGRA ROOF |
| | TILE PRODUCT APPROVAL AND INDICATE THE TYPE AND SIZE OF |
| | MECHANICAL TILE FASTENERS. THE SUBMITTED WORK SHEET |
| | APPEARS TO INDICATE BOTH SCREWS AND NAILS? |
| | 3) PLEASE REFER TO SECTION 708.8 FBC-14 EXISTING |
| | BUILDING. BECAUSE THE VALUE OF THE HOUSE NEXCEEDS |
| | $300,000, ROOF TO WALL CONNECTIONS MAY HAVE TO BE |
| | IMPROVED. |
| | 708.8 WHEN A ROOF COVERING ON AN EXISTING SITE-BUILT |
| | SINGLE FAMILY RESIDENTIAL STRUCTURE IS REMOVED AND |
| | REPLACED ON A BUILDING THAT IS LOCATED IN THE |
| | WIND-BORNE DEBRIS REGION AS DEFINED IN THE FLORIDA |
| | BUILDING CODE, BUILDING AND THAT HAS AN INSURED VALUE |
| | OF $300,000 OR MORE OR, IF THE BUILDING IS UNINSURED OR |
| | FOR WHICH DOCUMENTATION OF INSURED VALUE IS NOT |
| | PRESENTED, HAS A JUST VALUATION FOR THE STRUCTURE FOR |
| | PURPOSES OF AD VALOREM TAXATION OF $300,000 OR MORE: |
| | (A) ROOF TO WALL CONNECTIONS SHALL BE IMPROVED AS |
| | REQUIRED BY SECTION 708.8.1. |
| | (B) MANDATED RETROFITS OF THE ROOF-TO-WALL CONNECTION |
| | SHALL NOT BE REQUIRED BEYOND A 15-PERCENT INCREASE IN |
| | THE COST OF REROOFING. |
| | EXCEPTION: SINGLE-FAMILY RESIDENTIAL STRUCTURES |
| | PERMITTED SUBJECT TO THE FLORIDA BUILDING CODE ARE NOT |
| | REQUIRED TO COMPLY WITH THIS SECTION. |
| | |