Plan Review Details - Permit 16010493
Plan Review Stops For Permit 16010493
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2016-02-09 Cont ID  
Sent By skennedy Date 2016-02-09 Time 13:23 Rev Time 0.00
Received By skennedy Date 2016-02-09 Time 13:23 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-02-09 Cont ID  
Sent By skennedy Date 2016-02-09 Time 13:23 Rev Time 0.00
Received By skennedy Date 2016-02-09 Time 13:23 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2016-02-11 Cont ID  
Sent By pleduc Date 2016-02-11 Time   Rev Time 0.00
Received By pleduc Date 2016-02-11 Time 11:48 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2016-01-26 Cont ID  
Sent By pleduc Date 2016-01-26 Time   Rev Time 0.00
Received By pleduc Date 2016-01-26 Time 12:48 Sent To  
Notes
2016-01-26 13:00:35THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1. PER NFPA 241- STANDARD FOR SAFEGUARDING
 CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS,
 SECTION 4.2 TEMPORARY OFFICES AND SHEDS SHALL BE
 SEPARATED FROM ADJACENT TRAILERS OR STRUCTURES IN
 ACCORDANCE WITH TABLE 4.2.1. PER TABLE 4.2.1:
 1) 20 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 30 FEET
 2) 30 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 35 FEET
 3) 40 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 40 FEET
 4) 50 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 45 FEET
 5) 60 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 50 FEET
 6) GREATER THAN 60 FEET EXPOSED LENGTH SHALL BE
 SEPARATED FROM ADJACENT STRUCTURES BY AT LEAST 60 FEET
 **A 75 PERCENT REDUCTION IN SEPARATION DISTANCES SHALL
 BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC
 SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE.
  
 2. PROVIDE A SITE PLAN, INCLUDING ALL DIMENSIONS TO
 PROPOERTY LINES AND EXISTING AND PROPOSED BUILDINGS
 THAT COMPLY WITH NFPA 241 AS NOTED ABOVE.
  
 3. PROVIDE A STATEMENT INDICATING THE INSTALLATION OF A
 FIRE SPRINKLER SYSTEM UNDER SEPARATE SHOP DRAWINGS IF
 APPLICABLE FOR THE 75 PERCENT REDUCTION NOTED ABOVE.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-02-23 Cont ID  
Sent By lmarchan Date 2016-02-23 Time 12:34 Rev Time 0.00
Received By lmarchan Date 2016-02-09 Time 13:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-02-09 Cont ID  
Sent By skennedy Date 2016-02-09 Time 13:23 Rev Time 0.00
Received By skennedy Date 2016-01-19 Time 12:16 Sent To  
Notes
2016-01-20 12:16:53B30

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2016-02-09 Cont ID  
Sent By skennedy Date 2016-02-09 Time 13:23 Rev Time 0.00
Received By skennedy Date 2016-02-09 Time 13:23 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-02-05 Cont ID  
Sent By ccole Date 2016-02-05 Time 07:50 Rev Time 0.00
Received By ccole Date 2016-02-05 Time 07:49 Sent To  
Notes
2016-02-05 08:04:471ST REVIEW: FBC 2014 MECHANICAL
 PERMIT #16010493
 2/5/16
  
 1) PLEASE REFER TO PARAGRAPH 3 OF THE SUBMITTED LETTER
 FROM ROBERT LORENZO- DBPR MANUFFACTURED BUILDINGS
 PROGRAM: "EACH CODE CHANGE WILL MAKE YOUR PLANS
 OBSOLETE UNTIL THEY HAVE BEEN REVIEWED, APPROVED AND
 INDICATED (ON THE FRONT COVER PAGE OF THE PLANS) FOR
 COMPLIANCE WITH THE CODE BY YOUR THIRD PARTY AGENCY FOR
 PLANS REVIEW".
 PLEASE NOTE THE FRONT COVER PAGE OF THE SUBMITTED PLANS
 IS INDICATING DESIGN IN ACCORDANCE WITH THE 2010
 FLORIDA BUILDING CODES, HOWEVER THE CURRENT CODE IN
 EFFECT IS 2014- PLEASE UPDATE AND RE-SUBMIT THE PLANS
 ACCORDINGLY
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-02-10 Cont ID  
Sent By tklarge Date 2016-02-10 Time 13:36 Rev Time 0.00
Received By tklarge Date 2016-02-10 Time 13:36 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-01-24 Cont ID  
Sent By tklarge Date 2016-01-24 Time 04:49 Rev Time 0.00
Received By tklarge Date 2016-01-24 Time 04:31 Sent To  
Notes
2016-01-24 04:41:011)SUBMIT A SITE PLAN SHOWING HOW WATER AND SEWER
 SERVICE WILL BE PROVIDED TO THE MODULAR STRUCTURE.WPB
 AMEND. TO FBC SEC. 107.2.1.
 2) IF THE STRUCTURE WILL DISCHARGE TO A SEWAGE TANK,
 SHOW THE LOCATION ON THE SITE PLAN AND INDICATE THE
 CAPACITY OF THE TANK. TANKS EXCEEDING 300 GALLONS
 REQUIRE A PERMIT FROM THE PALM BEACH COUNTY HEALTH
 DEPT.
 3) THE WATER SERVICE TO THE STRUCTURE SHALL BE
 PROTECTED BY A BACKFLOW PREVENTION DEVICE. THE DEVICE
 SHALL BE LEAD FREE. SUBMIT TWO COPIES OF THE
 MANUFACTURER'S SPECIFICATIONS FOR THE BACKFLOW
 PREVENTION DEVICE.WPB AMEND. TO FBC SEC. 107.2.1.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2016-02-23 Cont ID  
Sent By eschneid Date 2016-02-23 Time 10:52 Rev Time 0.50
Received By eschneid Date 2016-02-23 Time 10:41 Sent To  
Notes
2016-02-23 10:52:31THE CONSTRUCTION TRAILER SHALL BE REMOVED WITHIN SEVEN
 DAYS OF THE FINAL CONSTRUCTION INSPECTION BY THE CITY
 AND PRIOR TO THE ISSUANCE OF A CERTIFICATE OF
 OCCUPANCY.
  
  

Review Stop Z ZONING
Rev No 1 Status F Date 2016-01-29 Cont ID  
Sent By eschneid Date 2016-01-29 Time 09:03 Rev Time 0.50
Received By eschneid Date 2016-01-28 Time 16:23 Sent To  
Notes
2016-01-29 09:09:58FAILED
  
 1) PROVIDE TWO COPIES OF THE SURVEY FOR THE SITE.
  
 2) PROVIDE THE SITE PLAN FOR THE SITE THAT SHOWS THE
 LOCATION OF THE TRAILER, THE ADA RAMP AND THE REQUIRED
 FIVE (5) PARKING SPACES. IF AN ADA PARKING SPACE IS
 REQUIRED, THEN IT SHALL BE PROVIDED (MAY BE ONE OF THE
 FIVE SPACES) AND BE PAVED AND HAVE A PAVED ACCESS AISLE
 AND BE APPROPRIATELY MARKED. DIMENSIONS TO THE PROPERTY
 LINE AND FOR THE TRAILERS AND PARKING SHALL BE SHOWN ON
 THE SITE PLAN.
  
 3) THE CONSTRUCTION TRAILER SHALL BE REMOVED WITHIN
 SEVEN DAYS OF THE FINAL CONSTRUCTION INSPECTION BY THE
 CITY AND PRIOR TO THE ISSUANCE OF A CERTIFICATE OF
 OCCUPANCY.
  
 4) THE TRAILER ITSELF COMPLIES WITH ZONING STANDARDS.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446.