Plan Review Details - Permit 16010349
| Plan Review Stops For Permit 16010349 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-01-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-01-28 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-01-27 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2016-01-27 09:55:04 | SENT TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-01-14 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-01-14 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-01-13 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2016-01-13 15:07:58 | MECHANICAL INBOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2016-01-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-01-28 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-01-28 |
Time |
08:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-01-14 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-01-14 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-01-14 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2016-01-14 11:42:26 | 1ST REVIEW: FBC 2014 MECHANICAL | | | PERMIT #16010349 | | | 01/14/16 | | | | | | 1) THE EQUIPMENT SCHEDULES ON M-3 ARE NOT LEGIBLE AND | | | WILL NOT BE ABLE TO BE SCANNED AND COPIED FOR PUBLIC | | | RECORD FILING- REFER TO SECTION 107.2.1 WPB AMENDMENTS | | | TO THE FBC-10 BUILDING. | | | 2) THE PLANS SHALL BE SIGNED AND SEALED BY THE ENGINEER | | | OF RECORD BARRY P. PITTS P.E. IN ACCORDANCE WITH | | | SECTION 61G15-23.002 FLORIDA ADMINISTRATIVE CODE. THE | | | SEAL MUST BE A RAISED SEAL OR INK SEAL: ELECTRONIC | | | SEALS ON PAPER PLANS ARE NOT ACCEPTED BY THE WPB | | | CONSTRUCTION SERVICES DEPT. | | | 3) SHEET S-1: PROVIDE THE WIND LOAD DESIGN CRITERIA | | | INCLUDING: WIND DESIGN CRITERIA | | | 2010 FBC-B 1609.1.1 DETERMINATION OF WIND DESIGN- | | | CHAPTER 6 OF ASCE 7-10. | | | 1609.3 BASIC WIND SPEED FIGURE 1609.A-C | | | 1609.3 WIND SPEED CONVERSION | | | A) THE BASIC WIND SPEED, VU, SHALL BE DETERMINED IN | | | ACCORDANCE WITH 1609.3.1 & ASCE 7-10 | | | B) AN IMPORTANCE FACTOR, FIGURE 1609 A-C, ASCE 7-10. | | | C) AN EXPOSURE CATEGORY SHALL BE DETERMINED IN | | | ACCORDANCE WITH 1609.4 & ASCE 7-10 | | | D) A HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENT, * | | | SHALL BE DETERMINED FROM TABLE 1609.7.2. ASCE 7-10. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
|