| Plan Review Stops For Permit 16010287 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2016-02-16 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2016-02-16 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2016-02-16 |
Time |
16:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-02-08 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2016-02-08 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2016-02-08 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2016-02-08 16:12:13 | ****CORRECTIONS**** | | | | | | ART LANGE - BUILDING INSPECTOR | | | 561-805-6667 [email protected] | | | FBC FLORIDA BUILDING CODE 2014 5TH EDITION | | | | | | NO NEW INFORMATION SUBMITTED FOR REVIEW: | | | | | | 1. PLEASE PROVIDE TIE DOWN ENGINEERING COMPLYING WITH | | | FBC 1603.1.4. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-01-21 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2016-01-21 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2016-01-21 |
Time |
16:58 |
Sent To |
E |
|
| Notes |
| 2016-01-21 17:01:43 | ****CORRECTIONS**** | | | | | | ART LANGE - BUILDING INSPECTOR | | | 561-805-6667 [email protected] | | | FBC FLORIDA BUILDING CODE 2014 5TH EDITION | | | | | | 1. PLEASE PROVIDE TIE DOWN ENGINEERING COMPLYING WITH | | | FBC 1603.1.4. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-02-05 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-02-05 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-02-05 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2016-02-05 10:03:34 | SENT TO CAROLYN/LAURA DESK |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-01-28 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-01-28 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-01-28 |
Time |
14:08 |
Sent To |
I |
|
| Notes |
| 2016-01-28 14:39:30 | 1ST ELECTRICAL REVIEW NOTES: | | | REVIEWED FOR COMPLIANCE WITH: | | | FBC 5TH EDITION 2014 | | | NFPA 70 2011 (NEC) | | | | | | CORRECTIONS REQUIRED: | | | 1. ACCORDING TO THE MANUFACTURER?S SPECS THIS UNIT HAS | | | A 125 AMP PANEL, (ASSUMED TO BE 120/240 VAC 1? | | | SERVICE), THE REQUIRED EXTERNAL LIGHT AND GFCI | | | PROTECTED OUTLET. | | | 2. YOU NEED TO SUBMIT AN ELECTRICAL RISER DIAGRAM AS | | | REQUIRED BY NEC 215.5. THIS DIAGRAM MUST INCLUDE | | | CONDUCTOR SIZING AND TYPE. THE CONDUCTORS MUST BE SIZED | | | TO SO AS NOT TO PERMIT GREATER THAN 3% VOLTAGE DROP. | | | 3. YOU NEED TO MARK ON THE SITE PLAN THE LOCATION OF | | | THE POWER SOURCE FOR THE UNIT. | | | 4. IF A SERVICE RACK IS GOING TO BE ERECTED, PROTECTION | | | FROM PHYSICAL DAMAGE MUST BE PROVIDED. | | | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | | RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER | | | (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER | | | WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD | | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID | | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | | GREATLY APPRECIATED. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU, | | | MIKE ALBARRAN | | | ELECTRICAL PLANS EXAMINER | | | PH: 561-805-6746 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-02-16 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2016-02-16 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2016-02-11 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2016-02-11 10:25:57 | RESUB ROUTED TO ACLANGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-02-08 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2016-02-08 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2016-02-02 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2016-02-02 12:54:43 | RESUB ROUTED TO MALBARRAN |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-01-28 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-01-28 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-01-12 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2016-01-28 14:48:35 | 1/28/16 FAILED TRADE REVIEWS. CONTRACTOR NOTIFIED VIA | | | EMAIL TO [email protected]. SENT FILE TO SMALL | | | DENIED BIN "L".MA | | 2016-01-12 14:35:40 | ROUTED TO ZONING |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2016-01-20 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2016-01-20 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2016-01-20 |
Time |
14:29 |
Sent To |
B |
|
| Notes |
| 2016-01-20 14:30:27 | PROVISO | | | | | | ALL CONSTRUCTION TRAILERS SHALL BE REMOVED WITHIN SEVEN | | | DAYS OF THE FINAL CONSTRUCTION INSPECTION BY THE CITY | | | AND PRIOR TO THE ISSUANCE OF A CERTIFICATE OF | | | OCCUPANCY. | | | | | | QUESTIONS/COMMENTS, CONTACT | | | JOHN ROACH, PRINCIPAL PLANNER, AT | | | [email protected] OR (561) 822-1448. | | | |
|
|