| 2016-01-19 08:32:42 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 16010199 |
| | ADD: 651 OKEECHOBEE BLVD. SUITE # 150 |
| | CONT: CHANDLIER CONSTRUCTION |
| | TEL: 561-791-6934 |
| | E-MAIL: |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: TUES. JAN. 19/ 2016 |
| | ACTION: DENIED |
| | |
| | 1) SHEET A0.0 UNDER THE HEDING OF BUILDING NFORMATION |
| | LIST THIS AS A 14 STORY BUILDING, TYPE IB. PLEASE NOTE |
| | FOR EITHER A BUSINESS OR R2 OCCUPANCY THE BUILDING TYPE |
| | WOULD BE A TYPE 1A NOT A 1B. SEE 2014 FBC-B TABLE 503. |
| | |
| | 2) SHEET A-1.0 INDICATES THERE ARE 278 OCCUPANTS WHERE |
| | DINING SURFACES ARE PROVIDED FOR THE CONSUMPTION OF |
| | FOOD OR DRINK, AT LEAST 5 PERCENT OF THE SEATING SPACES |
| | AND STANDING SPACES AT THE DINING SURFACES SHALL COMPLY |
| | WITH 902. THE PLANS INDICATE WHERE 13 ACCESSIBLE |
| | OCCUPANT LOCATIONS ON THE PLANS. THE 2014 |
| | FBC-ACCESSIBILITY CODE SECTION 226.1 REQUIRING 5 |
| | PERCENT OF 278 OCCUPANTS (278 X 0.5%= 13.9) OR 14 |
| | ACCESSIBLE SPACES. |
| | |
| | 3) SHEET A-1.0 INDICATES (2) BARS THE TOTAL OCCUPANT |
| | LOAD OF BOTH BARS IS 26. 26 X 0.5%= 1.3 OR 2 ACCESSIBLE |
| | SPACES SHOULD BE OFFERED AT THE BARS, THEY SHOULD BE |
| | DISPERSED. 2014 FBC-ACCESSIBILITY CODE 226.2 |
| | DISPERSION. DINING SURFACES AND WORK SURFACES REQUIRED |
| | TO COMPLY WITH 902 SHALL BE DISPERSED THROUGHOUT THE |
| | SPACE OR FACILITY CONTAINING DINING SURFACES AND WORK |
| | SURFACES. |
| | |
| | 4) NONE OF THE PLANS SHOW COMPLIANCE WITH THE 2014 |
| | FBC-ACCESSIBILITY CODE FOR 902.3 HEIGHT. THE TOPS OF |
| | DINING SURFACES AND WORK SURFACES SHALL BE 28 INCHES |
| | (710 MM) MINIMUM AND 34 INCHES (865 MM) MAXIMUM ABOVE |
| | THE FINISH FLOOR OR GROUND. |
| | |
| | 5) SHEET A5.1 PLEASE PROVIDE THE CALCULATIONS FOR THE |
| | WEIGHT OF THE DROPPED WINE BARREL CEILING, AND PROVIDE |
| | CALCULATIONS FOR THE FASTENERS ULTAMATE LOADS THEY CAN |
| | HOLD ALLOWABLE LOADS FOR TAP CONS THAT WERE NOT |
| | INSPECTED AND THE DERATING TO BE TAKEN, LIST THE TYPE |
| | OF FASTENER, & MANUFACTURER. |
| | |
| | 6) SHEET A5.1 THE DROPPED WINE BARREL CEILING, PLEASE |
| | PROVIDE COMPLIANCE WITH THE 2014 FBC-B SECTION 803.11.2 |
| | SET-OUT CONSTRUCTION. |
| | WHERE WALLS AND CEILINGS ARE REQUIRED TO BE OF |
| | FIRE-RESISTANCE-RATED OR NONCOMBUSTIBLE CONSTRUCTION |
| | AND WALLS ARE SET OUT OR CEILINGS ARE DROPPED DISTANCES |
| | GREATER THAN SPECIFIED IN SECTION 803.11.1, CLASS A |
| | FINISH MATERIALS, IN ACCORDANCE WITH SECTION 803.1.1 OR |
| | 803.1.2, SHALL BE USED. |
| | EXCEPTIONS: |
| | 1. WHERE INTERIOR FINISH MATERIALS ARE PROTECTED ON |
| | BOTH SIDES BY AN AUTOMATIC SPRINKLER SYSTEM IN |
| | ACCORDANCE WITH SECTION 903.3.1.1 OR 903.3.1.2. |
| | |
| | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | JAMES A. WITMER CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |
| | |
| | |