Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-01-15 Cont ID  
Sent By jgomez Date 2016-01-15 Time 17:43 Rev Time 0.00
Received By jgomez Date 2016-01-15 Time 17:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-01-07 Cont ID  
Sent By jgomez Date 2016-01-07 Time 16:51 Rev Time 0.00
Received By jgomez Date 2016-01-07 Time 16:19 Sent To  
Notes
2016-01-07 16:57:52RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS.
 CODE: FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 1- FLAT ROOF NOA 14-0224.03 SUBMITTED:
 A) CLEARLY IDENTIFY WHICH APPROVED ASSEMBLY IS GOING TO
 BE INSTALLED TO VERIFY COMPLIANCE WITH THE DESIGN
 PRESSURES OF SEC. R301 OF FBC-RESIDENTIAL, 5TH EDITION
 (2014).
  
 B) PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS AS
 REQUIRED BY GENERAL LIMITATION #7 ON LAST PAGE OF NOA
 14-0224.03 SUBMITTED. NEED THE RAS 117 CALCULATIONS TO
 MEET THE DESIGN PRESSURES OF SEC.R301 OF
 FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 NOTE: NOTICE OF COMMENCEMENT WILL BE REQUIRED FOR THE
 ROOFING WORK.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-01-15 Cont ID  
Sent By jgomez Date 2016-01-15 Time 17:31 Rev Time 0.00
Received By jgomez Date 2016-01-15 Time 17:30 Sent To  
Notes
2016-01-15 17:30:45MET WITH JIM TO GO OVER COMMENTS. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-01-07 Cont ID  
Sent By jgomez Date 2016-01-07 Time 16:19 Rev Time 0.00
Received By jgomez Date 2016-01-06 Time 14:51 Sent To  
Notes
***NONE***