Plan Review Details - Permit 16010118
Plan Review Stops For Permit 16010118
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-03-25 Cont ID  
Sent By jwitmer Date 2016-03-25 Time 06:45 Rev Time 0.00
Received By jwitmer Date 2016-03-25 Time 06:31 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-02-02 Cont ID  
Sent By jwitmer Date 2016-02-02 Time 07:45 Rev Time 0.00
Received By jwitmer Date 2016-02-02 Time 07:01 Sent To  
Notes
2016-02-02 07:45:13BUILDING PLAN REVIEW
 W. P. B. PERMIT: 16010118
 ADD: 330 SOUTHERN BLVD.
 CONT: PRIME MECHANICAL SERVICES
 TEL: 954-448-8870
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. FEB. 02/ 2016
 ACTION: DENIED
  
 1) TARNOWSKI ENGINEERING SHEET 1 OF 2 SHOWS THE SIZE OF
 THE SLAB BUT THERE IS NO CROSS SECTION OF THE SLAB
 SHOWING THE DEPTH SLAB REINFORCING NOR THE THICKENED
 MONOLITHIC FOUNDATION. 2014 FBC-B 1809.4 DEPTH AND
 WIDTH OF FOOTINGS. THE MINIMUM DEPTH OF FOOTINGS BELOW
 THE UNDISTURBED GROUND SURFACE SHALL BE 12 INCHES (305
 MM). WHERE APPLICABLE, THE REQUIREMENTS OF SECTION
 1809.5 SHALL ALSO BE SATISFIED. THE MINIMUM WIDTH OF
 FOOTINGS SHALL BE 12 INCHES.
  
 2) 2014 FBC-B 1810.3.9.2 REQUIRED REINFORCEMENT. WHERE
 SUBJECT TO UPLIFT OR WHERE THE REQUIRED MOMENT STRENGTH
 DETERMINED USING THE LOAD COMBINATIONS OF SECTION
 1605.2
  
 3) 2014 FBC-B 1816.1 TERMITE PROTECTION. TERMITE
 PROTECTION SHALL BE PROVIDED BY REGISTERED
 TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES,
 BAITING SYSTEMS, AND PESTICIDES APPLIED TO WOOD, OR
 OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED
 FOR USE AS A PREVENTATIVE TREATMENT TO NEW
 CONSTRUCTION.
  
 4) MIAMI TECH SHEET FOR A CONDENSOR BRACKET IS A
 PHOTO-COPIED SEAL NOT ORIGINAL, SEAL STATES THAT IT IS
 NOT VALID UNLESS IT IS A RAISED SEAL. PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS PREPARED BY
 THE DESIGN PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE DESIGN
 PROFESSIONAL AFFIXED TO THE DOCUMENT.
 FL ADMIN CODE 61G15-23.002 ENGINEERS/ EFFECTIVE DATE
 05/06/2009
  
 5) PLEASE SHOW ON THE FLOOR SLAB PLANS WHERE THE
 CONDENSOR AND CONDENSOR BRACKET ARE TO BE INSTALLED,
 LOCATED IN A WALL ZONE 4 OR WALL ZONE 5?
 2014 FBC-B 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
  
 5.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED,
 VASD, AS DETERMINED IN ACCORDANCE WITH SECTION
 1609.3.1.
  
 5.2. RISK CATEGORY.
  
 5.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED.
  
 5.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
  
 5.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL
 RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/
 M2).
  
 6) TARNOWSKI ENGINEERING SHEET 1 OF 2 SHOWS A NEW
 PROPOSED RAMP OF 11 FEET LONG. PLEASE PROVIDE
 COMPLIANCE WITH 2014 FBC-B :
 1010.1 SCOPE.
 THE PROVISIONS OF THIS SECTION SHALL APPLY TO RAMPS
 USED AS A COMPONENT OF A MEANS OF EGRESS.
  
 EXCEPTIONS:
  
 1. OTHER THAN RAMPS THAT ARE PARTS OF ACCESSIBLE ROUTES
 PROVIDING ACCESS IN ACCORDANCE WITH THE PROVISIONS OF
 THE FLORIDA BUILDING CODE, ACCESSIBILITY, RAMPED AISLES
 WITHIN ASSEMBLY ROOMS OR SPACES SHALL CONFORM TO THE
 PROVISIONS IN 1028.11.
  
 2. CURB RAMPS NOT SUBJECT TO FLORIDA BUILDING CODE,
 ACCESSIBILITY, SHALL COMPLY WITH ICC ANSI A117.1.
  
 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-03-29 Cont ID  
Sent By vperez Date 2016-03-29 Time 09:42 Rev Time 0.00
Received By vperez Date 2016-03-29 Time 09:41 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-02-02 Cont ID  
Sent By skennedy Date 2016-02-02 Time 15:52 Rev Time 0.00
Received By skennedy Date 2016-02-02 Time 15:52 Sent To  
Notes
2016-02-02 15:57:31FIRST REVIEW
  
 NEC 2011
  
 PLEASE PROVIDE A PANEL LOAD CALCULATION REFLECTING NEW
 LOADS TO NEW EXTERIOR WALK-IN COOLER FROM EXISTING
 400AMP PANELBOARD.
 FBC 107, NEC 220.16B
  
 VAL PEREZ
 561-805-6717
 ELECTRICAL PLANS EXAMINER

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-03-29 Cont ID  
Sent By vperez Date 2016-03-29 Time 09:46 Rev Time 0.00
Received By vperez Date 2016-03-29 Time 09:46 Sent To  
Notes
2016-03-29 09:47:03TO CAROLINE FOR COMPLETION
2016-03-22 13:16:29B07

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-02-04 Cont ID  
Sent By ajones Date 2016-02-04 Time 17:27 Rev Time 0.00
Received By ajones Date 2016-01-06 Time 16:30 Sent To  
Notes
2016-01-06 16:30:40B28

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2016-03-28 Cont ID  
Sent By ccole Date 2016-03-28 Time 10:07 Rev Time 0.00
Received By ccole Date 2016-03-28 Time 10:07 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-01-25 Cont ID  
Sent By ccole Date 2016-01-25 Time 14:02 Rev Time 0.00
Received By ccole Date 2016-01-25 Time 14:02 Sent To  
Notes
2016-01-25 14:15:371ST REVIEW: FBC 2014 MECHANICAL
 PERMIT #16010118
 01/25/16
  
 1) PROVIDE REFRIGERATION EQUIPMENT SCHEDULES THAT
 INCLUDE THE MAKES AND MODELS OF THE EVAPORATOR AND
 CONDENSER, AND THE TYPE AND QUANITY OF REFRIGERANT IN
 THE SYSTEM.
 2) SHOW THE LOCATION OF THE CONDENSER ON THE PLAN, AND
 PROVIDE SITE-SPECIFIC ENGINEERING FOR THE BRACKET
 ATTACHMENT, AND TIE-DOWN OF THE CONDENSER TO THE
 BRACKET. PLEASE NOTE THE SUBMITTAL FOR THE MIAMI-TECH
 CU BRACKET HAS A COPIED ENGINEER'S SEAL- AN ORIGINAL
 SEAL AND SIGNATUTRE IS REQUIRED PER FAC SECTION
 61G15-23.002.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status P Date 2016-02-04 Cont ID  
Sent By sgraham Date 2016-02-04 Time 17:25 Rev Time 0.00
Received By ajones Date 2016-02-04 Time 17:25 Sent To  
Notes
***NONE***