Plan Review Details - Permit 16010076
Plan Review Stops For Permit 16010076
Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2016-02-18 Cont ID  
Sent By mgonzale Date 2016-02-18 Time   Rev Time 1.00
Received By mgonzale Date 2016-02-18 Time   Sent To  
Notes
2016-02-18 12:25:19PBC HEALTH DEPARTMENT PERMIT.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2016-02-23 Cont ID  
Sent By wjolin Date 2016-02-23 Time 11:19 Rev Time 0.00
Received By wjolin Date 2016-02-23 Time 10:50 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2016-02-03 Cont ID  
Sent By wjolin Date 2016-02-03 Time 16:40 Rev Time 0.00
Received By wjolin Date 2016-02-03 Time 16:26 Sent To  
Notes
2016-02-03 16:26:255001 NORTH MILITARY TRAIL
 PERMIT #16010076
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 IN ORDER TO WORK ON A DEDICATED FIRE WATER MAIN, THE
 CONTRACTOR NEEDS TO BE STATE OF FLORIDA CONTRACTOR I OR
 CONTRACTOR V PER FLORIDA STATUTE 633. THE CURRENT
 APPLICANT IS A CGC1514178.
  
 JOINT RESTRAINT: PER NFPA 13 & 24, SECTION 10.8.1.1,
 ALL TEES, PLUGS, CAPS, BENDS, REDUCERS, VALVES, AND
 HYDRANT BRANCHES SHALL BE RESTRAINED AGAINST MOVEMENT
 BY USING THRUST BLOCKS OR RESTRAINED JOINT SYSTEMS.
  
 CORROSION RESISTANCE: PER NFPA 13 & 24, SECTION
 10.8.3.5, AFTER INSTALLATION, RODS, NUTS, BOLTS,
 WASHERS, CLAMPS, AND OTHER RESTRAINING DEVICES SHALL BE
 CLEANED AND THOROUGHLY COATED WITH A BITUMINOUS OR
 OTHER ACCEPTABLE CORROSION-RETARDING MATERIAL.
  
 ACCEPTANCE REQUIREMENTS: PER NFPA 13 & 24, SECTION
 10.10.2.1.3, UNDERGROUND PIPING, FROM THE WATER SUPPLY
 TO THE SYSTEM RISER, AND LEAD-IN CONNECTIONS TO THE
 SYSTEM RISER SHALL BE COMPLETELY FLUSHED BEFORE
 CONNECTION IS MADE TO DOWNSTREAM FIRE PROTECTION SYSTEM
 PIPING. THE MINIMUM RATE OF FLOW SHALL BE NOT LESS THAN
 THE FLOW NECESSARY TO PROVIDE A VELOCITY OF 10 FEET PER
 SECOND.
  
 FLUSHING PAPERS: PER NFPA 13 & 24, SECTION 10.10.1, THE
 INSTALLING CONTRACTOR SHALL BE RESPONSIBLE FOR THE
 COMPLETING AND SIGNING THE CONTRACTOR'S MATERIAL AND
 TEST CERTIFICATE(S) SHOWN IN FIGURE 10.10.1.
  
 HYDROSTATIC TESTING: PER NFPA 13 & 24, SECTION
 10.10.2.2.1 ALL PIPING AND ATTACHED APPURTENANCES
 SUBJECTED TO SYSTEM WORKING PRESSURE SHALL BE
 HYDROSTATICALLY TESTED AT 200 PSI OR 50 PSI IN EXCESS
 OF THE SYSTEM WORKING PRESSURE, WHICHEVER IS GREATER,
 AND SHALL MAINTAIN THAT PRESSURE +/-5 PSI FOR 2 HOURS.
  
 PROVIDE CHAIN WITH LOCK AND TAMPER SWITCHES FOR
 SUPERVISING THE BACKFLOW PREVENTER IN THE OPEN
 POSITION.
  
 PROVIDE LOCKING KNOX CAPS ON FIRE DEPARTMENT
 CONNECTION.
  
 PROVIDE PERMANENT WEATHERPROOF SIGN MARKING THE FIRE
 DEPARTMENT CONNECTION.
  
 WESLEY JOLIN
 ASSISTANT FIRE MARSHAL
 FIRE INVESTIGATOR & INSPECTOR
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 805-6730

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-03-01 Cont ID  
Sent By ccole Date 2016-03-01 Time 16:13 Rev Time 0.00
Received By ccole Date 2016-02-19 Time 13:08 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-02-19 Cont ID  
Sent By lmarchan Date 2016-02-19 Time 07:40 Rev Time 0.00
Received By lmarchan Date 2016-01-20 Time 10:44 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2016-03-01 Cont ID  
Sent By ccole Date 2016-03-01 Time 16:13 Rev Time 0.00
Received By ccole Date 2016-03-01 Time 16:13 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-02-04 Cont ID  
Sent By ccole Date 2016-02-04 Time 16:58 Rev Time 0.00
Received By ccole Date 2016-02-04 Time 16:58 Sent To  
Notes
2016-02-04 17:02:521ST REVIEW: FBC 2014 MECHANICAL
 PERMIT #16010076
 2/4/16
  
 1) PROVIDE DETAILS ON THE PLAN FOR JOINT RESTRAINT OF
 TEES, PLUGS, CAPS, BENDS, REDUICERS, VALVES, AND
 HYDRANT BRANCHES.
 2) PROVIDE A SUBMITTAL PACKAGE THAT INCLUDES CUT SHEETS
 FOR THE PIPING, PIPE CONNECTORS, AND THE BACKFLOW
 PREVENTOR. ALL SUBMITTALS SHALL BE REVIEWED AND
 APPROVED WITH SIGNATURE BY THE DESIGN PROFESSIONAL OF
 RECORD.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2016-03-07 Cont ID  
Sent By skennedy Date 2016-03-07 Time 16:43 Rev Time 0.00
Received By skennedy Date 2016-03-07 Time 16:43 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2016-03-01 Cont ID  
Sent By skennedy Date 2016-03-01 Time 16:59 Rev Time 0.00
Received By skennedy Date 2016-03-01 Time 16:59 Sent To  
Notes
2016-03-01 17:00:22ALL SHEETS NOT S&S.