Plan Review Details - Permit 15120919
Plan Review Stops For Permit 15120919
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-02-08 Cont ID  
Sent By skennedy Date 2016-02-08 Time 08:48 Rev Time 0.00
Received By skennedy Date 2016-02-08 Time 08:48 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-01-29 Cont ID  
Sent By jgomez Date 2016-01-28 Time 18:35 Rev Time 0.00
Received By jgomez Date 2016-01-27 Time 11:27 Sent To  
Notes
2016-01-28 18:35:48NEW SINGLE FAMILY RESIDENCE (R3), BUILDING REVIEW
 COMMENTS.
 CODE: FBC 5TH EDITION (2014)
  
 NOTE:
 BUILDING REVIEW MAY BE APPROVED WITH PROVISO. REVISION
 FEES MAY APPLY. CONTRACTOR TO ADVICE IF PROVISO OPTION
 IS ACCEPTABLE.
  
 1- ENERGY CALCULATIONS SUBMITTED ARE TAKING THE CROSS
 VENTILATION CREDIT. PROVIDE COMPLETE INFORMATION
 SHOWING HOW THE PLANS COMPLY WITH ALL THE REQUIREMENTS
 OF SEC. R405.7.4 OF FBC-ENERGY CONSERVATION, 5TH
 EDITION (2014).
  
 2- ENERGY CALCULATIONS SUBMITTED:
 A) ITEM #5 OF ENERGY CALCULATIONS STATE THAT THE
 CALCULATIONS ARE NO WORST CASE SCENARIO, BUT PAGE 2 OF
 4 STATES THAT HOUSE WAS ROTATED 90 DEGREES. THIS IS NOT
 CLEAR. REVISE AS REQUIRED. SEC. 107.2.1 CITY
 AMENDMENTS.
 NOTE: ENERGY CALCULATIONS MAY BE DONE FOR WORST CASE
 SCENARIO, BUT EQUIPMENT SIZING CALCULATIONS NEED TO BE
 DONE TO THE ACTUAL ORIENTATION OF THE BUILDING.
  
 B) OWNER/AGENT TO CERTIFY AND DATE BOTTOM OF FORM AS
 REQUIRED BY SEC. R103.1.1.2 OF FBC-ENERGY CONSERVATION,
 5TH EDITION (2014).
  
 C) REVISE THE CLIMATE ZONE SHOWN ON PAGE 2 OF 4. SEE
 TABLE C301.1 OF FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014).
  
 D) REVISE THE TYPE OF ROOF SHOWN ON PAGE 2 OF 4. PLANS
 SUBMITTED DON'T SHOW HIP ROOF. SEC. R103.2 OF
 FBC-ENERGY CONSERVATION, 5TH EDITION (2014).
  
 E) REVISE THE WINDOWS OVERHANG DEPTH AND SEPARATION TO
 MATCH PLANS. SEC. R103.1.1.2 OF FBC-ENERGY
 CONSERVATION, 5TH EDITION (2014).
  
 F) COMPLETE THE CHECK LIST ON TABLE 402.4.1.1
 SUBMITTED.
  
 G) COMPLETE THE ENERGY PERFORMANCE LEVEL (EPL) DISPLAY
 CARD SUBMITTED.
  
 NOTE:
 LABEL FOR DOORS AND WINDOWS SHOWING THE U-FACTOR AND
 SHGC FACTOR SPECIFIED ON THE ENERGY CALCULATIONS WILL
 BE REQUIRED WHEN THE ENERGY CALCULATIONS ARE NOT USING
 THE SOFTWARE DEFAULT FACTOR FOR GLAZING.
  
 3- WINDOW AND DOOR SCHEDULE ON SHEET A-3.0: ENTRY DOOR
 SAYS "NR". CLARIFY WHY THE ENTRY DOOR DOESN'T HAVE TO
 COMPLY WITH THE EGRESS REQUIREMENTS. SEC. R11 OF
 FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 4- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. VALUATION WAS UPDATED TO $150,000. THE PERMIT FEE
 BALANCE IS $973.38. SEC. 109.3 CITY AMENDMENTS.
  
 5- REVISE THE DESIGN PARAMETERS NOTE ON SHEET A-3.0:
 THE BUILDING DOESN'T HAVE A HIP ROOF. THE DESIGN
 PRESSURES ON A HIP ROOF AND A GABLE ROOF ARE DIFFERENT.
 REVISE AS REQUIRED. SEC. R301 OF FBC-RESIDENTIAL, 5TH
 EDITION (2014).
  
 6- SIZE OF FOOTING S1 SHOWN ON SHEET S-1.0 DOESN'T
 MATCH SIZE SHOWN ON TYPICAL WALL SECTION.
 REVISE/CLARIFY AS REQUIRED. WHICH ONE IS THE CORRECT
 SIZE?. SEC. R301 OF FBC-RESIDENTIAL, 5TH EDITION
 (2014).
  
 7- RE-SUBMIT PRODUCT APPROVAL REQUIRED BY FAC
 61G20-3.002(33) FOR: EXTERIOR DOORS. FLORIDA PRODUCT
 APPROVAL FL11136-R1 SUBMITTED IS FOR THE 2010 CODE
 VERSION. NEED THE CURRENT 2014 CODE VERSION.
 NOTE: REVISE ALL PRODUCT APPROVAL NUMBERS ON SHEET
 A-3.0 AS WELL.
  
 8- DESIGNER OF RECORD TO APPROVED ABOVE PRODUCT
 APPROVALS PRIOR TO SUBMITTAL. SEC. 107.3.4.1 CITY
 AMENDMENTS.
  
 9- REVISE SURVEY. BUILDING IS LOCATED IN FLOOD ZONE "B"
 NOT "C". SEC. 107.2.1 CITY AMENDMENTS.
  
 10- PROVIDE SOIL TEST REPORT AS REQUIRED BY SEC. R401.4
 OF FBC-RESIDENTIAL, 5TH EDITION (2014).
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSIGN EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2016-02-08 Cont ID  
Sent By skennedy Date 2016-02-08 Time 08:47 Rev Time 0.00
Received By skennedy Date 2016-02-08 Time 08:47 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-01-27 Cont ID  
Sent By mvaldes Date 2016-01-27 Time 17:50 Rev Time 0.00
Received By mvaldes Date 2016-01-27 Time 17:27 Sent To  
Notes
2016-01-27 17:54:071ST REVIEW: FBC 2014 5TH ED. NEC 2011/RESIDENTIAL
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 516-805-6700
 [email protected]
 ALTERNATE CONTACT
 MIKE ALBARRAN
 561-805-6746
 [email protected]
  
  
 PROVISO
  
 -NEC 406.11- PROVIDE TAMPER RESISTANT RECEPTACLES.
 -NEC 210.63 - PROVIDE A GFI SERVICE OUTLET FOR WITHIN
 25? OF MECHANICAL EQUIPMENT.
 -FBC-ER 404.1.1 / 402.4.4
 RECESSED LIGHTS SHALL BE 75 % HIGH EFFICIENT
 AS WELL AS IC RATED AND SEALED TO NOT COMPROMISE
 BUILDING THERMAL ENVELOPE. ( 2 CFM )
 - PLEASE INSTALL 50 AMP BKR FOR RANGE NEC 210.21 B

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-02-08 Cont ID  
Sent By skennedy Date 2016-02-08 Time 08:48 Rev Time 0.00
Received By skennedy Date 2016-02-02 Time 11:03 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-01-29 Cont ID  
Sent By jgomez Date 2016-01-29 Time 16:21 Rev Time 0.00
Received By jgomez Date 2016-01-04 Time 14:17 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2016-02-08 Cont ID  
Sent By skennedy Date 2016-02-08 Time 08:48 Rev Time 0.00
Received By skennedy Date 2016-02-08 Time 08:48 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2016-01-28 Cont ID  
Sent By jgomez Date 2016-01-28 Time 18:36 Rev Time 0.00
Received By jgomez Date 2016-01-28 Time 18:36 Sent To  
Notes
2016-01-28 18:38:481- BRING PLANS TO PALM BEACH COUNTY (2300 N. JOG RD.)
 FOR IMPACT FEES ASSESSMENT. BRING BACK COUNTY STAMPED
 PLANS AND COPY OF PAID RECEIPT IF FEES ARE DUE. COUNTY
 IMPACT FEE ORDINANCE OF THE UNIFIED LAND DEVELOPMENT
 CODE.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2016-02-08 Cont ID  
Sent By skennedy Date 2016-02-08 Time 08:48 Rev Time 0.00
Received By skennedy Date 2016-02-08 Time 08:48 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-01-29 Cont ID  
Sent By jgomez Date 2016-01-29 Time 15:22 Rev Time 0.00
Received By jgomez Date 2016-01-29 Time 09:29 Sent To  
Notes
2016-01-29 15:30:01NEW SINGLE FAMILY RESIDENCE (R3), MECHANICAL REVIEW
 COMMENTS.
 CODE: FBC 5TH EDITION (2014)
  
 NOTE:
 MECHANICAL REVIEW MAY BE APPROVED WITH PROVISO.
 REVISION FEES MAY APPLY. CONTRACTOR TO ADVICE IF
 PROVISO OPTION IS ACCEPTABLE.
  
 1- EQUIPMENT SIZING CALCULATIONS NEED TO BE DONE WITH
 THE ACTUAL ORIENTATION OF THE BUILDING AS REQUIRED BY
 SEC. R403.06 OF FBC-ENERGY CONSERVATION, 5TH EDITION
 (2014). CALCULATIONS SUBMITTED ARE NOT DONE FOR THE
 ACTUAL ORIENTATION OF THE BUILDING. FOR EXAMPLE, THERE
 ARE NOT WINDOWS ON THE WEST SIDE WITH AN OVERHANG
 LENGTH OF 6.5FT. REVISE ALL CALCULATIONS AS REQUIRED TO
 MATCH PLANS.
  
 ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH
 COMMENT TO EXPEDITE THE REVIEW PROCESS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 (561)805-6712
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-02-08 Cont ID  
Sent By skennedy Date 2016-02-08 Time 08:48 Rev Time 0.00
Received By skennedy Date 2016-02-08 Time 08:48 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-01-09 Cont ID  
Sent By tklarge Date 2016-01-09 Time 06:10 Rev Time 0.00
Received By tklarge Date 2016-01-09 Time 05:37 Sent To  
Notes
2016-01-09 06:09:451) CLEARLY SHOW ON THE RISER HOW THE SHOWER IN THE
 MASTER BATH IS CONNECTED TO THE BELOW SLAB BUILDING
 DRAIN. THE RISER IS UNCLEAR, PIPING IS NOT CLEARLY
 SHOWN . WPB AMEND. TO FBC SEC. 107.2.1.
 2) THE VENT FOR THE WATER CLOSET IN THE MASTER BATH
 APPEARS TO BE DRAWN AS A FLAT, DRY VENT. THE BASE OF
 THE VENT MUST BE WASHED BY A FIXTURE. THE VENT SHALL
 CONNECT TO THE HORIZONTAL DRAIN ABOVE THE CENTERLINE OF
 THE HORIZONTAL DRAIN PIPE PER 2014 FBCR SEC.P3104.3.
 THE SEPARATE VENT FOR THE WATER CLOSET IS NOT REQUIRED,
 IT IS VENTED BY THE STACK FOR THE LAVATORY.
 3) PLEASE CLARIFY HOW THE TUB AND WATER CLOSET ARE
 VENTED IN BATH #2. THE VENT FOR THE TUB ALSO APPEARS TO
 BE A FLAT, DRY VENT. CLARIFY.
 4) SHT. L1.0 SHOWS THAT DROUGHT TOLERANT PLANTS & SOD
 WILL BE INSTALLED. DOES THIS MEAN THAT THERE WILL NOT
 BE AN IRRIGATION SYSTEM INSTALLED ON THIS STRUCTURE?
 CLARIFY. IF AN IRRIGATION SYSTEM WILL BE INSTALLED,
 THEN AN APPROVED BACCKFLOW PREVENTER, CONTROLLER, AND
 RAIN SENOSR WILL BE REQUIRED ON THE SYSTEM.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2016-01-29 Cont ID  
Sent By jgomez Date 2016-01-29 Time 16:19 Rev Time 0.00
Received By jgomez Date 2016-01-29 Time 16:19 Sent To  
Notes
2016-01-29 16:21:011- SHINGLES NOA 12-0309.01.
  
 2- ROOF VENTS. NOA 13-0820.08.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2016-02-08 Cont ID  
Sent By skennedy Date 2016-02-08 Time 08:56 Rev Time 0.00
Received By skennedy Date 2016-02-08 Time 08:56 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2016-02-04 Cont ID  
Sent By dkittred Date 2016-02-04 Time 16:48 Rev Time 0.00
Received By dkittred Date 2016-02-04 Time 16:00 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2016-01-14 Cont ID  
Sent By sgraham Date 2016-01-14 Time 11:49 Rev Time 0.00
Received By sgraham Date 2016-01-14 Time 11:49 Sent To  
Notes
2016-01-14 11:50:321/14/16 ZONING FAILED
  
 1. SUBMIT TWO CERTIFIED UP TO DATE SURVEYS. ALL NEW
 CONTRUCTION PROJECTS REQUIRE UP TO DATE SURVEYS.
2016-01-08 15:50:321/8/16