Plan Review Details - Permit 15120845
Plan Review Stops For Permit 15120845
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-03-21 Cont ID  
Sent By jwitmer Date 2016-03-21 Time 13:38 Rev Time 0.00
Received By jwitmer Date 2016-03-21 Time 13:23 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-03-10 Cont ID  
Sent By jwitmer Date 2016-03-10 Time 07:00 Rev Time 0.00
Received By jwitmer Date 2016-03-10 Time 06:31 Sent To  
Notes
2016-03-10 06:52:14BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15120845
 ADD: 1801 S. FLAGLER DR. SUITE # 911
 CONT: TO BE DETERMINED
 TEL: 561-582-1945 K. MANCHEN ARCH.
 E-MAIL: ????????
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: THURS. MARCH 10/2016
 ACTION: DENIED
  
 1) SHEET 1&2 OF 5 TILE AND STONE WORK NOTES INDICATE
 THE FLOOR SOUND INSULATION TO BE AN APPROVED SOUND
 LAYER OF WHISPER MAT HC-71.
  
 1A) COMPLIED.
  
 1B) PLEASAE PROVIDE THE ACTUAL TEST REPORTS FOR THE
 WHISPER MAT HC-17. MUST MEET THE 3 TEST LISTED BELOW,
  
 BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION (FBC-B
 2014)
 PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH:
 1C) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 1D) FBC-B 2014 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 1E) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 2) COMPLIED.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-01-09 Cont ID  
Sent By jwitmer Date 2016-01-09 Time 08:30 Rev Time  
Received By jwitmer Date 2016-01-09 Time 08:00 Sent To  
Notes
2016-01-09 08:35:33BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15120845
 ADD: 1801 S. FLAGLER DR. SUITE # 911
 CONT: TO BE DETERMINED
 TEL: 561-582-1945 K. MANCHEN ARCH.
 E-MAIL: ????????
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: SAT. JAN. 09/2016
 ACTION: DENIED
  
 1) SHEET 1 OF 5 TILE AND STONE WORK NOTES INDICATE THE
 FLOOR SOUND INSULATION TO BE AN APPROVED SOUND LAYER OF
 EASY MAT OR EQUAL.
  
 1A) THE WORDING OF OR EQUAL DOES NOT MEET THE
 REQUIREMENTS OF 2014 FLORIDA BUILDING CODE W 2014 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1, ADMINISTRATION 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS. DRAWINGS AND SPECIFICATIONS
 SHALL CONTAIN INFORMATION, IN THE FORM OF NOTES OR
 OTHERWISE, AS TO THE QUALITY OF MATERIALS, WHERE
 QUALITY IS ESSENTIAL TO CONFORMITY WITH THE TECHNICAL
 CODES. SUCH INFORMATION SHALL BE SPECIFIC, AND THE
 TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE OR IN
 PART, NOR SHALL THE TERM "LEGAL" OR ITS EQUIVALENT BE
 USED AS A SUBSTITUTE FOR SPECIFIC INFORMATION.
  
 1B) EASY MAT DOES NOT HAVE TESTING REPORTS MEETING THE
 3 CODE SECTIONS BELOW.
  
 BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION (FBC-B
 2014)
 PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH:
 1C) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 1D) FBC-B 2014 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 1E) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
 2) SHEETS 2 & 5 BOTH SHOW TILE WORK ON THE BATH WALLS,
 THE PLANS DO NOT MENTION THE TYPE OF BACKER BOARD
 (WALL) THE TILE WORK SHALL ADHERE. PLEASE INDICATE HOW
 CODE COMPLIANCE WITH THE 2014 FBC-B SECTION
 2509.2 BASE FOR TILE.
 GLASS MAT WATER-RESISTANT GYPSUM BACKING PANELS,
 DISCRETE NONASBESTOS FIBER-CEMENT INTERIOR SUBSTRATE
 SHEETS OR NONASBESTOS FIBER-MAT REINFORCED CEMENTITIOUS
 BACKER UNITS IN COMPLIANCE WITH ASTM C 1178, C 1288 OR
 C 1325 AND INSTALLED IN ACCORDANCE WITH MANUFACTURER
 RECOMMENDATIONS SHALL BE USED AS A BASE FOR WALL TILE
 IN TUB AND SHOWER AREAS AND WALL AND CEILING PANELS IN
 SHOWER AREAS. WATER-RESISTANT GYPSUM BACKING BOARD
 SHALL BE USED AS A BASE FOR TILE IN WATER CLOSET
 COMPARTMENT WALLS WHEN INSTALLED IN ACCORDANCE WITH
 GA-216 OR ASTM C 840 AND MANUFACTURER RECOMMENDATIONS.
 REGULAR GYPSUM WALLBOARD IS PERMITTED UNDER TILE OR
 WALL PANELS IN OTHER WALL AND CEILING AREAS WHEN
 INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C 840.
  
 2509.3 LIMITATIONS.
 WATER-RESISTANT GYPSUM BACKING BOARD SHALL NOT BE USED
 IN THE FOLLOWING LOCATIONS:
  
 1. OVER A VAPOR RETARDER IN SHOWER OR BATHTUB
 COMPARTMENTS.
  
 2. WHERE THERE WILL BE DIRECT EXPOSURE TO WATER OR IN
 AREAS SUBJECT TO CONTINUOUS HIGH HUMIDITY.
  
 3. ON CEILINGS WHERE FRAME SPACING EXCEEDS 12 INCHES
 (305 MM) O.C. FOR 1/2-INCH THICK (12.7 MM)
 WATER-RESISTANT GYPSUM BACKING BOARD AND MORE THAN 16
 INCHES (406 MM) O.C. FOR 5/8-INCH THICK (15.9 MM)
 WATER-RESISTANT GYPSUM BACKING BOARD.
  
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-03-09 Cont ID  
Sent By mvaldes Date 2016-03-09 Time 16:09 Rev Time 0.00
Received By mvaldes Date 2016-03-09 Time 16:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-02-04 Cont ID  
Sent By mvaldes Date 2016-02-04 Time 18:29 Rev Time 0.00
Received By mvaldes Date 2016-02-04 Time 18:29 Sent To  
Notes
2016-02-04 18:30:111ST REVIEW: FBC 2014 5TH ED. NEC 2011/RESIDENTIAL
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 516-805-6713
 [email protected]
 ALTERNATE CONTACT
 MIKE ALBARRAN
 561-805-6746
 [email protected]
  
 -FBC-ER 404.1.1 / 402.4.4 ( ADD TO NOTES )
 RECESSED LIGHTS SHALL BE 75 % HIGH EFFICIENT
 AS WELL AS IC RATED AND SEALED TO NOT COMPROMISE
 BUILDING THERMAL ENVELOPE. ( 2 CFM )
  
 -PLEASE PROVIDE A PANEL SCHEDULE NEC 408.4A TO ENSURE
 THAT KITCHEN COUNTER TOP RECEPTACLES SHALL BE SUPPLIED
 BY NO FEWER THAN TWO SMALL APPLIANCE BRANCH CIRCUITS.
 NEC 210.52 B3
  
 -SMOKE ALARMS REQUIRED PER RESIDENTIAL CODE SECTIONS
 314 & 315. VERIFY LOCATIONS TO THE FOLLOWING :
 SMOKE ALARMS AND SMOKE DETECTORS SHALL NOT BE INSTALLED
 WITHIN A 36 IN. (910 MM) OF AC DUCTS AND HORIZONTAL
 PATH FROM A DOOR TO A BATHROOM CONTAINING A SHOWER OR
 TUB UNLESS LISTED FOR INSTALLATION IN CLOSE PROXIMITY
 TO SUCH LOCATIONS. RELOCATE THE UNITS ACCORDINGLY.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2016-03-04 Cont ID  
Sent By pleduc Date 2016-03-04 Time   Rev Time 0.00
Received By pleduc Date 2016-03-04 Time 12:50 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-12-30 Cont ID  
Sent By pleduc Date 2015-12-31 Time   Rev Time 0.00
Received By pleduc Date 2015-12-30 Time 16:16 Sent To  
Notes
2015-12-30 16:18:29THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
 1. THE NATURE OF THE REMODEL MAY REQUIRE AN EVALUATION
 OF THE FIRE ALARM AND SPRINKLER SYSTEM FOR CODE
 COVERAGE AND COMPLIANCE.
  
 2. THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE
 SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE
 CONSTRUCTION PERIOD.
  
 3. ANY AND ALL WORK ON THE FIRE ALARM AND FIRE
 SPRINKLER SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP
 DRAWINGS AND BY CERTIFIED LIFE SAFETY CONTRACTORS.
  
 4. ANY TIME THAT WORK ON THE LIFE SAFETY SYSTEMS,
 SPRINKLER AND/OR FIRE ALARM, EXCEEDS 4 HOURS, A FIRE
 WATCH SHALL BE IMPLEMENTED AND MAINTAINED UNTIL FULL
 AND COMPLETE PROTECTION IS RETURNED.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-03-21 Cont ID  
Sent By jwitmer Date 2016-03-21 Time 13:38 Rev Time 0.00
Received By jwitmer Date 2016-03-17 Time 15:44 Sent To  
Notes
2016-03-17 15:44:44RESUB ROUTED TO JWITMER

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-03-10 Cont ID  
Sent By ccole Date 2016-03-10 Time 16:56 Rev Time 0.00
Received By ccole Date 2016-03-02 Time 13:04 Sent To  
Notes
2016-03-10 16:58:43MECHANICAL PROVISO:
 PERMITT #15120845
 3/10/16
  
 1) PER ARCHITECT KAREN MANNCHEN, A REVISED AC PLAN WILL
 BE SUBMITTED FOR REVIEW AND APPROVAL PRIOR TO1ST
 MECHANICAL INSPECTION.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  
2016-03-02 13:04:34B09

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-02-05 Cont ID  
Sent By cpuell Date 2016-02-05 Time 08:58 Rev Time 0.00
Received By cpuell Date 2015-12-29 Time 14:56 Sent To  
Notes
2015-12-29 14:57:34B02

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2016-03-10 Cont ID  
Sent By ccole Date 2016-03-10 Time 16:56 Rev Time 0.00
Received By ccole Date 2016-03-10 Time 16:29 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-01-04 Cont ID  
Sent By ccole Date 2016-01-04 Time 07:26 Rev Time 0.00
Received By ccole Date 2016-01-04 Time 06:59 Sent To  
Notes
2016-01-04 07:38:131ST REVIEW: FBC 2014 MECHANICAL
 PERMIT #15120845
 01/04/15
  
 1) SHEET #2: THE LOUVERED DOOR AT THE AHU CLOSET CANNOT
 BE WOOD AS SPECIFIED IN THE SCHEDULE. IN ACCORDANCE
 WITH C403.2.7.2 FBC-14 ENERGY CONSERVATION AND SECTION
 602 FBC-14 MECHANICAL THE DOOR SHALL BE MADE OF
 NON-COMBUSTIBLE MATERIALS.
 2) SHEET #3: INDICATE A MEANS OF RETURN AIR FROM THE
 BEDROOM AND THE GUEST ROOM IN ACCORDANCE WITH SECTION
 601.5 FBC-14 MECHANICAL.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-03-07 Cont ID  
Sent By tklarge Date 2016-03-07 Time 05:46 Rev Time 0.00
Received By tklarge Date 2016-03-07 Time 05:32 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2016-01-04 Cont ID  
Sent By gjohnson Date 2016-01-04 Time 15:45 Rev Time 0.00
Received By gjohnson Date 2016-01-04 Time 15:45 Sent To  
Notes
2016-01-04 15:53:411ST REVIEW: FBC 2014
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
 1.SCOPE OF PLUMBING WORK IS UNCLEAR PLEASE PROVIDE A
 COMPLEATE SCOPE OF PLUMBING WORK .PER WPB AMEND TO FBC
 SEC107.2.1
 2. SHEET 1 BATH 1 SHOWS TUB SHEET 2 BATH 2 SHOWS SHOWER
 PLEASE CLARIFY.PER WPB AMEND TO FBC SEC107.2.1
 3.SHEET 1 SHOWS OPEN SPACE IN BATH 2 SHEET2 SHOWS
 SHOWER IN BATH 2 PLEASE CLERIFY.PER WPB AMEND TO FBC
 SEC107.2.1
 4. IS THER A EXISTING WASHING MACHINE. PER WPB AMEND TO
 FBC SEC107.2.1
 5.PROVIDE PLUMBING RISER DIAGRAM FOR ALL NEW PLUMBING.
 PER WPB AMEND TO FBC SEC 107.3.5.3(11)