Plan Review Details - Permit 15120730
Plan Review Stops For Permit 15120730
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2016-01-07 Cont ID  
Sent By cthroop Date 2016-01-07 Time 15:22 Rev Time 0.00
Received By cthroop Date 2016-01-07 Time 15:22 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-01-14 Cont ID  
Sent By mvaldes Date 2016-01-14 Time 14:28 Rev Time 0.00
Received By mvaldes Date 2016-01-14 Time 14:28 Sent To  
Notes
2016-01-14 14:50:36FBC 2014 5TH ED. NEC 2011/RESIDENTIAL
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 516-805-6700
 [email protected]
 ALTERNATE CONTACT
 MIKE ALBARRAN
 561-805-6746
 [email protected]
  
 THIS PERMIT SHALL BE ISSUED WITH A PROVISO ON GFCI
 PROTECTION ON BOAT HOIST NEC 210.8 C

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-01-07 Cont ID  
Sent By mvaldes Date 2016-01-07 Time 16:41 Rev Time 0.00
Received By mvaldes Date 2016-01-07 Time 16:40 Sent To  
Notes
2016-01-07 16:49:181ST REVIEW: FBC 2014 5TH ED. NEC 2011
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 516-805-6700
 [email protected]
 ALTERNATE CONTACT
 MIKE ALBARRAN
 561-805-6746
 [email protected]
  
 PLEASE PROVIDE LOCATION OF ELECTRICAL EQUIPMENT IN
 RELATION TO EACH OTHER ON SITE PLAN. WPB FBC 107.3.1.2
 PLEASE GIVE ME A PANEL SCHEDULE SHOWING CIRCUIT
 IDETIFICATION WIRE, CONDUIT, AND PROTECTION SIZE NEC
 408.4
 FBC E C405.7.3.1 FEEDERS AND CUSTOMER OWNED SERVICE
 CONDUCTORS.
 FEEDER AND CUSTOMER OWNED SERVICE CONDUCTORS SHALL BE
 SIZED FOR A MAXIMUM VOLTAGE DROP OF 2 PERCENT AT DESIGN
 LOAD.
 FBC E C405.7.3.2 BRANCH CIRCUITS.
 BRANCH CIRCUIT CONDUCTORS SHALL BE SIZED FOR A MAXIMUM
 VOLTAGE DROP OF 3 PERCENT AT DESIGN LOAD.
 PROVIDE MAINTNANCE GFCI OUTLET FOR BOAT DOCKS NEC 555
 NEC 210.8C BOAT HOISTS. GFCI PROTECTION SHALL BE
 PROVIDED FOR
 OUTLETS NOT EXCEEDING 240 VOLTS THAT SUPPLY BOAT HOISTS
 INSTALLED
 IN DWELLING UNIT LOCATIONS.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-01-19 Cont ID  
Sent By lmarchan Date 2016-01-19 Time 10:33 Rev Time 0.00
Received By lmarchan Date 2016-01-13 Time 10:50 Sent To  
Notes
2016-01-13 10:51:02RESUB ROUTED TO MVALDES

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-01-08 Cont ID  
Sent By cpuell Date 2016-01-08 Time 09:59 Rev Time 0.00
Received By cpuell Date 2015-12-22 Time 13:32 Sent To Z
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2016-01-06 Cont ID  
Sent By cpuell Date 2016-01-08 Time 09:59 Rev Time 0.00
Received By sgraham Date 2016-01-06 Time 15:49 Sent To AIPP
Notes
***NONE***