| Plan Review Stops For Permit 15120611 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2016-03-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-03-16 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-03-16 |
Time |
09:40 |
Sent To |
|
|
| Notes |
| 2016-03-16 11:52:33 | BUILDING PLAN REVIEW | | | W. P.B. PERMIT: 25120611 | | | ADD: 700 S. ROSEMARY AVE. SUITE # 212 | | | CONT: ADCON ADVANCED CONSTRUCTION | | | TEL: 561-856-6655 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: WED. MARCH 16/2016 | | | ACTION: BUILDING PROVISO | | | | | | 1) PROVISO/ DEFERRED SUBMITTAL :2014 FLORIDA BUILDING | | | CODE W 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION 107.3.4.2. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA | | | RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN WRITING BY | | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP CURBS & | | | ATTACHMENTS TO RTU AND OR ROOF TOP FANS | | | (G) PRE-ENGINEERED A/C STANDS | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-02-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-02-25 |
Time |
06:45 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-02-25 |
Time |
05:47 |
Sent To |
|
|
| Notes |
| 2016-02-25 05:59:53 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 25120611 | | | ADD: 700 S. ROSEMARY AVE. SUITE # 212 | | | CONT: ADCON ADVANCED CONSTRUCTION | | | TEL: 561-856-6655 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | | | | 2ND REVIEW | | | DATE: THURS. FEB. 25/2016 | | | ACTION: DENIED | | | | | | 1-2) COMPLIED. | | | | | | 3) 2ND REQUEST. PLEASE PROVIDE A DEMO SHEET OR PROVIDE | | | A EXISTING LAY OUT AND WHAT IS NEW FOR COMPARISON. THE | | | INTERIOR DEMO PERMIT (15110848) WAS DESIGNED UNDERTHE | | | SAME ARCHITECT. PLEASE NOTE THERE ARE ELEMENTS REMOVED | | | UNDERTHE DEMO PERMIT THAT WILL CONSTITUTE NEW WORK AND | | | HAVE TO COMPLY WITH: 2014 EXISTING BUILDING CODE LEVEL | | | II 701.3 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, | | | COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE | | | REQUIREMENTS OF THE FLORIDA BUILDING CODE, BUILDING. | | | ONE AREA IN QUESTION IS THE REMOVAL OF STAIR LABELED | | | D-8. 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 4) COMPLIED. PLEASE PROVIDE CALCULATIONS FOR PLATFORM | | | CONSTRUCTION INCOMPLIANCE WITH 2014 FBC-B 410.4 WHERE | | | THE PLATFORMS ARE NOT MORE THAN 30 INCHES (762 MM) | | | ABOVE THE MAIN FLOOR, AND NOT MORE THAN ONE-THIRD OF | | | THE ROOM FLOOR AREA AND NOT MORE THAN 3,000 SQUARE FEET | | | (279 M2) IN AREA. | | | | | | 5) 2ND REQUEST. THE AREA OF RAISED PLATFORM INTHE UPPER | | | PORTION OF THE PLANS INDICATES A RAISED PLATFORM WITH | | | AN OCCUPANT LOAD GREATER THAN 50AND WITH ONLY 1 | | | ACCESSIBLE MEANS OF EGRESS(RAMP). WITH THE REMOVAL OF | | | STAIR TO THE LEFT PORTION OF THE RAISED PLATFROM (STAIR | | | D-8 ON DEMO PERMIT) THE 2ND ACCESSIBLE MEANS OF EGRESS | | | CAN NOW BE BUILT WITH THE 2ND RAMP ANS | | | REQUIREDHANDRAILS. SHEET A6 SHOWS (2) RAISED PLATFORM | | | DINING AREAS UPPER PORTION OF THE PLANS BY THE MAIN | | | ENTRY THE OTHER TO THE LOWER PORTION OF THE MAIN ENTRY. | | | IN BOTH DINING AREAS THE OCCUPANT LOAD IS GREATER THAN | | | 50 AND WILL NEED TO SHOW COMPLIANCE WITH THE 2014 | | | FBC-ACCESSIBILITY CODE SECTION 207.1 MEANS OF EGRESS | | | SHALL COMPLY WITH SECTION 1003.2.13 OF THE | | | INTERNATIONAL BUILDING CODE (2000 EDITION AND 2001 | | | SUPPLEMENT) OR SECTION 1007 OF THE INTERNATIONAL | | | BUILDING CODE (2003 EDITION). THE LOWER PORTION IS NOT | | | BEING TOUCHED, UNDER THE EXISITNG BUILDING CODE LEVEL | | | II ALTERATIONS THIS IS NOT ADDRESSED. PLEASE NOTE THAT | | | BEING SAID, IT DOES NOT RELIEVE THE OWNER FROM A | | | BARRIER FREE DESIGN UNDER THE ADA AND LIABLE TO LAW | | | SUIT. | | | | | | ***2003 IBC-B 1007.1 *** WHERE MORE THAN ONE MEANS OF | | | EGRESS IS REQUIRED BY SECTIONS 1014.1 OR 1018.1 FROM | | | ANY ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF THE | | | SPACE SHALL BE SERVED BY NOT LESS THAN TWO MEANS OF | | | EGRESS. | | | | | | | | | 6) 2ND REQUEST. PLEASE SHOW COMPLIANCE WITH 2014 | | | FBC-ACCESSIBILITY CODE: | | | 6A) 2ND REQUEST. 221.2.1.1 GENERAL SEATING. WHEELCHAIR | | | SPACES COMPLYING WITH 802.1 SHALL BE PROVIDED IN | | | ACCORDANCE WITH 2014 ACC.CODE SECTION 226.1 5% OF THE | | | OVERALL SEATING. SEATING COUNT 357 SEATS/.05= 23 | | | ACC.SEATS. | | | | | | | | | 6B) 2ND REQUEST. 226.2 DISPERSION. DINING SURFACES AND | | | WORK SURFACES REQUIRED TO COMPLY WITH 902 SHALL BE | | | DISPERSED THROUGHOUT THE SPACE OR FACILITY CONTAINING | | | DINING SURFACES AND WORK SURFACES. THE PLANS SHOW 3 OF | | | THE ACCESSIBLE SEATS AT A SERVER POINT OF SALE STATION | | | AND NOT IN THE DINING ROOM. THE PLANS DO NOT SHOW ANY | | | ACCESSIBLE SEATING IN THE OUTDOOR SEATING AREA.THE | | | PRIVATE DINING ROOM OR INTHE BOOTH AREAS AS WELL AS THE | | | HIGH TOP SEATING ADJACENT TO THE BAR. | | | | | | 6C) SEMI-COMPLIED. THE PLANS WILL NEED TO SHOW THE | | | ADDITIONAL ACCESSIBLE SEATING REQUIRED. 902.2 CLEAR | | | FLOOR OR GROUND SPACE. A CLEAR FLOOR SPACE COMPLYING | | | WITH 305 POSITIONED FOR A FORWARD APPROACH SHALL BE | | | PROVIDED. KNEE AND TOE CLEARANCE COMPLYING WITH 306 | | | SHALL BE PROVIDED. | | | | | | 6D) 2ND REQUEST. NOT SHOWN 902.3 HEIGHT. THE TOPS OF | | | DINING SURFACES AND WORK SURFACES SHALL BE 28 INCHES | | | (710 MM) MINIMUM AND 34 INCHES (865 MM) MAXIMUM ABOVE | | | THE FINISH FLOOR OR GROUND. | | | | | | 6E) COMPLIED. | | | | | | 7) COMPLIED. EXISITNG. | | | | | | 8) PROVISO/ DEFERRED SUBMITTAL :2014 FLORIDA BUILDING | | | CODE W 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | | BUILDING CODE, CHAPTER 1, ADMINISTRATION 107.3.4.2. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | THE MECHANICAL SHEETS SHOW A ROOF TOP UNIT, OARTU-1. IS | | | THIS A EXISITNG UNIT OR NEW? IF NEW PLEASE PROVIDE THE | | | ENGINEERING FOR THE NEW ROOF TOP OPENING, NEW ROOF TOP | | | CURB AND TIE DOWN OF THE CURB AS WELL AS THE TIE DOWN | | | OF THE ROOF TOP UNIT TO THE CURB. 1609.6.4.4.1 | | | COMPONENTS & CLADDING | | | | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP CURBS | | | (G) PRE-ENGINEERED A/C STANDS | | | | | | 9) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-01-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-01-07 |
Time |
08:33 |
Rev Time |
|
| Received By |
jwitmer |
Date |
2016-01-07 |
Time |
06:30 |
Sent To |
|
|
| Notes |
| 2016-01-07 08:18:44 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 25120611 | | | ADD: 700 S. ROSEMARY AVE. SUITE # 212 | | | CONT: ADCON ADVANCED CONSTRUCTION | | | TEL: 561-856-6655 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | | | | 1ST REVIEW | | | DATE: THURS. JAN. 07/2016 | | | ACTION: DENIED | | | | | | 1) COVERSHEET DOES NOT SHOW A INDEX OF PLANS NOR WITHIN | | | THE SET OF PLANS IS THERE A EGRESS SHEET SHOWING THE | | | EGRESS THROUGH OUT THE TENANT SPACE, EXIT DIRECTIONALS, | | | EXIT LIGHTS NOR EMERGENCY LIGHTS OR EMERGENCY BATTERY | | | BACK UP LIGHTS. | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION 107.3.5.1.1. MINIMUM PLAN REVIEW | | | CRITERIA FOR COMMERCIAL BUILDINGS. | | | (7.) OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: | | | MEANS OF EGRESS | | | EXIT ACCESS | | | EXIT | | | EXIT DISCHARGE | | | STAIRS CONSTRUCTION/GEOMETRY | | | | | | 2) THE COVERSHEET LIST THIS AS A BUILDING TYPE II | | | BUILDING. THIS BUILDING WAS BUILT UNDER THE 1997 SBCCI | | | CODE AS A TYPE II BUILDING. UNDER THE 2014 FBC-B THIS | | | EQUATES TO A TYPE IB BUILDING TYPE, PLEASE UPDATE | | | PLANS. | | | | | | 3) PLEASE PROVIDE A DEMO SHEET OR PROVIDE A EXISTING | | | LAY OUT AND WHAT IS NEW FOR COMPARISON. 107.2.1.3 | | | ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 4) PLEASE PROVIDE CALCULATIONS FOR PLATFORM | | | CONSTRUCTION INCOMPLIANCE WITH 2014 FBC-B 410.4 WHERE | | | THE PLATFORMS ARE NOT MORE THAN 30 INCHES (762 MM) | | | ABOVE THE MAIN FLOOR, AND NOT MORE THAN ONE-THIRD OF | | | THE ROOM FLOOR AREA AND NOT MORE THAN 3,000 SQUARE FEET | | | (279 M2) IN AREA. | | | | | | 5) SHEET A6 SHOWS (2) RAISED PLATFORM DINING AREAS ONE | | | LEFT OF THE MAIN ENTRY THE OTHER TO THE RIGHT OF THE | | | MAIN ENTRY. IN BOTH DINING AREAS THE OCCUPANT LOAD IS | | | GREATER THAN 50 AND WILL NEED TO SHOW COMPLIANCE WITH | | | THE 2014 FBC-ACCESSIBILITY CODE SECTION 207.1 MEANS OF | | | EGRESS SHALL COMPLY WITH SECTION 1003.2.13 OF THE | | | INTERNATIONAL BUILDING CODE (2000 EDITION AND 2001 | | | SUPPLEMENT) OR SECTION 1007 OF THE INTERNATIONAL | | | BUILDING CODE (2003 EDITION). | | | | | | 2003 IBC-B 1007.1 WHERE MORE THAN ONE MEANS OF EGRESS | | | IS REQUIRED BY SECTIONS 1014.1 OR 1018.1 FROM ANY | | | ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF THE SPACE | | | SHALL BE SERVED BY NOT LESS THAN TWO MEANS OF EGRESS. | | | | | | 6) PLEASE SHOW COMPLIANCE WITH 2014 FBC-ACCESSIBILITY | | | CODE: | | | 6A) 221.2.1.1 GENERAL SEATING. WHEELCHAIR SPACES | | | COMPLYING WITH 802.1 SHALL BE PROVIDED IN ACCORDANCE | | | WITH TABLE 221.2.1.1. | | | | | | 6B) 226.2 DISPERSION. DINING SURFACES AND WORK SURFACES | | | REQUIRED TO COMPLY WITH 902 SHALL BE DISPERSED | | | THROUGHOUT THE SPACE OR FACILITY CONTAINING DINING | | | SURFACES AND WORK SURFACES. | | | | | | 6C) 902.2 CLEAR FLOOR OR GROUND SPACE. | | | A CLEAR FLOOR SPACE COMPLYING WITH 305 POSITIONED FOR A | | | FORWARD APPROACH SHALL BE PROVIDED. KNEE AND TOE | | | CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED. | | | | | | 6D) 902.3 HEIGHT. | | | THE TOPS OF DINING SURFACES AND WORK SURFACES SHALL BE | | | 28 INCHES (710 MM) MINIMUM AND 34 INCHES (865 MM) | | | MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | | | | 6E) SHEET A-17 DETAILS D & H BOTH SHOW ACCESSIBLE | | | HANDRAILS FOR STAIRS BUT NO FOR RAMPS, RAMP HANDRAILS | | | REQUIRE COMPLIANCE WITH 2014 FBC-ACCESSIBILITY CODE | | | 505.10.1 RAMPS TOP AND BOTTOM EXTENTIONS AT RAMPS. | | | | | | 7A) SHEET A-17 SHOWS WHAT IS CALLED A EQUIPMENT | | | PLATFORM, PLEASE SGOW COMPLIANCE WITH 505.3.1 AREA | | | LIMITATION. THE AGGREGATE AREA OF ALL EQUIPMENT | | | PLATFORMS WITHIN A ROOM SHALL BE NOT GREATER THAN | | | TWO-THIRDS OF THE AREA OF THE ROOM IN WHICH THEY ARE | | | LOCATED. THIS APPEARS TO BE A STORY. | | | | | | 7B) SHOW COMPLIANCE WITH 505.3.2 AUTOMATIC SPRINKLER | | | SYSTEM. WHERE LOCATED IN A BUILDING THAT IS REQUIRED TO | | | BE PROTECTED BY AN AUTOMATIC SPRINKLER SYSTEM, | | | EQUIPMENT PLATFORMS SHALL BE FULLY PROTECTED BY | | | SPRINKLERS ABOVE AND BELOW THE PLATFORM, WHERE REQUIRED | | | BY THE STANDARDS REFERENCED IN SECTION 903.3. | | | | | | 8) THE MECHANICAL SHEETS SHOW A ROOF TOP UNIT, OARTU-1. | | | IS THIS A EXISITNG UNIT OR NEW? IF NEW PLEASE PROVIDE | | | THE ENGINEERING FOR THE NEW ROOF TOP OPENING, NEW ROOF | | | TOP CURB AND TIE DOWN OF THE CURB AS WELL AS THE TIE | | | DOWN OF THE ROOF TOP UNIT TO THE CURB. 1609.6.4.4.1 | | | COMPONENTS & CLADDING | | | | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP CURBS | | | (G) PRE-ENGINEERED A/C STANDS | | | | | | 9) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2016-03-22 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-03-22 |
Time |
19:09 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-03-22 |
Time |
18:39 |
Sent To |
FIRE |
|
| Notes |
| 2016-03-22 19:10:05 | REVISED SHEET SUBMITTED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2016-03-03 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-03-03 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-03-02 |
Time |
18:41 |
Sent To |
I |
|
| Notes |
| 2016-03-03 11:13:34 | TRYING TO FOLLOW THE NARRATIVE I REALIZED THAT I HAD AN | | | OLD AND UNREVISED SHEET E3.1. WHILE LOOKING FOR THE | | | SHOW WINDOW OUTLETS ON THE OLDER SHEET I WENT TO THE | | | ARCHITECTURAL DRAWINGS AND NOTICED THAT WHAT APPEARS TO | | | BE AN OPEN AREA ON THE ELECTRICAL SHEET IS A CLOSED | | | ROOM ON THE SHEET A3 REQUIRING LIGHTING AND LIGHTING | | | CONTROL. I SPOKE W/GORDON SCOTT THE PROJECT MANAGER TO | | | CONFIRM MY FINDINGS. HE WILL RESUBMIT CORRECTED SHEETS. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-01-21 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-01-21 |
Time |
18:58 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-01-21 |
Time |
13:40 |
Sent To |
I |
|
| Notes |
| 2016-01-21 18:59:41 | THE PLANS FOR THE ABOVE MENTIONED REVISION HAS BEEN | | | REVIEWED FOR COMPLIANCE WITH THE EDITION OF THE NEC, | | | (NATIONAL ELECTRICAL CODE), FIRE CODES AND THE FBC, | | | (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST | | | PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF | | | SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED. | | | | | | 1. THE APPLICABLE EDITION OF THE NEC IS THE 2011, AS | | | REFERENCED IN THE 5TH EDITION OF THE FBC-2014. CORRECT | | | SHEET A1. | | | 2. THERE ARE MANY MISSING EXIT LIGHTS TO NAME EACH. | | | PLEASE SEE YELLOW HIGHLIGHTS ON THE REVIEWED DRAWINGS | | | ON SHEET E2.1 | | | 3. FBC-E C402.4.8 RECESSED LIGHTING. RECESSED LIGHTING | | | INSTALLED IN THE BUILDING THERMAL ENVELOPE SHALL BE IC | | | RATED AND BE SEALED TO LIMIT AIR LEAKAGE BETWEEN | | | CONDITIONED & UNCONDITIONED SPACES. | | | 4. THE MANDATORY LIGHTING CONTROLS OF FBC-EC405 ARE | | | MISSING IN THE AREAS OF THE PROPOSED STORAGE AND | | | PROPOSED BEER COOLER. SEE LIGHTING SHEET HIGHLIGHTED IN | | | GREEN. | | | 5. SHEET E3.1A REFLECTS NEW STAIRS 2R & 3R. IF THESE | | | HAVE MORE THAN 6 RISERS, NEC AND REQUIRES ILLUMINATION | | | AND SWITCHING. | | | 6. NEC 210.62 SHOW WINDOWS. AT LEAST ONE RECEPTACLE | | | OUTLET SHALL BE INSTALLED WITHIN 18? OF THE TOP OF A | | | SHOW WINDOW FOR EVERY 12 LINEAR FT. OR MAJOR PORTION | | | THEREOF AREA MEASURED HORIZONTALLY. | | | 7. NEC 600.5 REQUIRED BRANCH CIRCUIT. EACH COMMERCIAL | | | BUILDING AND EACH COMMERCIAL OCCUPANCY ACCESSIBLE TO | | | PEDESTRIANS SHALL BE PROVIDED WITH AT LEAST ONE 20 AMP | | | DEDICATED OUTLET IN AN ACCESSIBLE LOCATION AT EACH | | | ENTRANCE TO EACH TENANT SPACE FOR SIGN OR OUTLINE | | | LIGHTING. SERVICE HALLWAYS OR CORRIDORS SHALL NOT BE | | | CONSIDERED ACCESSIBLE TO PEDESTRIANS. | | | 8. NEC 210.8(B) GROUND FAULT CIRCUIT-INTERRUPTER | | | PROTECTION OTHER THAN DWELLING UNITS. ALL KITCHEN | | | RECEPTACLES SHALL BE GFCI PROTECTED. | | | 9. THOUGH THE FIRE ALARM REQUIRES A SEPARATE PERMIT AND | | | SUBMITTAL, MAKE NOTE CHANGE TO DUCT DETECTOR TO | | | INITIATE A GENERAL ALARM. | | | 10. ACCORDING TO NFPA 72 SECTION 10.15, SMOKE DETECTOR | | | PROTECTION IS REQUIRED IN AREAS IDENTIFIED BY AN ASTRIX | | | * 10 ON THE FIRE ALARM FLOOR PLANS. | | | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | | RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE | | | LETTER (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE | | | NUMBER WHERE THE CORRECTIONS APPEAR ALONG WITH THE | | | STANDARD CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE | | | INSERT CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK | | | VOID AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | | GREATLY APPRECIATED. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU, | | | MIKE ALBARRAN | | | ELECTRICAL PLANS EXAMINER | | | PH: 561-805-6746 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2016-03-29 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-03-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-03-28 |
Time |
16:37 |
Sent To |
G |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2016-03-02 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-03-02 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-02-29 |
Time |
16:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2015-12-22 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-12-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-12-22 |
Time |
12:33 |
Sent To |
|
|
| Notes |
| 2015-12-22 13:28:37 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1. SHEET A - 1 - THE OCCUPANY LOAD CALCULATIONS FOR THE | | | STORAGE AND COOLER AREA APPEAR TO BE INCORRECT THOUGH | | | IT DOES NOT ADVERSELY AFFECT THE OVER ALL LOAD, IT MUST | | | BE CORRECTED. | | | | | | 2. SHEET A - 3 - DOOR D 1-7 APPEARS TO SWING IN BOTH | | | DIRECTIONS. PROVIDE CLEAR INDICATION THAT IT SWINGS IN | | | THE PATH OF EXIT EGRESS AND THERE IS NO LATCH. | | | | | | 3. SHEET E - 2.1 - EXIT SIGNAGE IS REQUIRED FOR EXIT | | | DOORS D1-5 AND D 1-7. CONFIRM EXIT SIGNS AT THE STORAGE | | | ROOM DOOR AND THE REAR CORRIDOR DOOR. | | | | | | 4. SHEET E 2-1 AND A - 4 - EMERGENCY LIGHTING REQUIRED | | | THROUGHOUT THE OCCUPANCY ONLY 5 ARE NOTED IN THE | | | KITCHEN AREA. PROVIDE INDICATION THAT THE EXIT SIGNS | | | PROVIDE THE REQUIRED EMERGENCY LIGHTING OR PROVIDE | | | ADDITIONAL EMERGENCY LIGHTING TO MEET THE REQUIRED | | | CANDELA PER NFPA 101 THROUGHOUT THE OCCUPANCY. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2016-03-23 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-03-23 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-03-23 |
Time |
13:23 |
Sent To |
|
|
| Notes |
| 2016-03-23 13:24:25 | MANUFACTURER'S SPECIFICATIONS SHALL BE ONSITE FOR | | | INSPECTION. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2016-03-16 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-03-16 |
Time |
17:35 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-03-16 |
Time |
17:35 |
Sent To |
|
|
| Notes |
| 2016-03-16 17:35:21 | GAS COMMENTS: | | | 3RD REQUEST | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL | | | CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS PER | | | FBC-2014 FUEL GAS, SECS. 402.4.1, 402.4.2. | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE EHD NUMBER OF CORRUGATED STAINLESS | | | STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. WPB | | | AMENDMENTS TO FBC SEC. 107.2.1. | | | | | | | | | | | | | | | 3. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, | | | (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING | | | AND/OR SYSTEM PER THE FBC-2014 FUEL GAS APPENDIX A ? | | | USE OF CAPACITY SECTION A.3.1(4) & 2014 FUEL GAS CODE | | | SEC. 402.4.1. | | | | | | 4. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | | FBC-2014 FUEL GAS CODE SEC. 304. | | | | | | 5. INDICATE THE DELIVERY PRESSURE (PSI) PER FBC-2014 | | | FUEL GAS SEC. 402.2. IF NATURAL GAS SPECIFY .5 PSI OR 2 | | | PSI. | | | | | | 6. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | | TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE | | | SEC. 502 THRU 505. | | | | | | 7. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | | | | | | | | 3RD REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2016-02-28 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-02-28 |
Time |
06:59 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-02-28 |
Time |
06:59 |
Sent To |
|
|
| Notes |
| 2016-02-28 07:00:47 | COMPLY WITH GAS COMMENTS FROM PREVIOUS GAS REVIEW. | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2016-01-04 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-01-04 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-01-04 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2016-01-04 12:07:46 | 1ST REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | GAS COMMENTS: | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL | | | CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS PER | | | FBC-2014 FUEL GAS, SECS. 402.4.1, 402.4.2. | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE EHD NUMBER OF CORRUGATED STAINLESS | | | STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. WPB | | | AMENDMENTS TO FBC SEC. 107.2.1. | | | | | | 3. TYPE OF GAS, (LP OR NATURAL). | | | | | | 4. SHEET P0.2 KITCHEN SCHEDULE E108, E99, E96 SHOW GAS | | | CONNECTION THOSE APPLIANCES DO NOT NEED GAS BUT WARE | | | PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 5. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, | | | (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING | | | AND/OR SYSTEM PER THE FBC-2014 FUEL GAS APPENDIX A ? | | | USE OF CAPACITY SECTION A.3.1(4) & 2014 FUEL GAS CODE | | | SEC. 402.4.1. | | | | | | 6. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | | FBC-2014 FUEL GAS CODE SEC. 304. | | | | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) PER FBC-2014 | | | FUEL GAS SEC. 402.2. IF NATURAL GAS SPECIFY .5 PSI OR 2 | | | PSI. | | | | | | 8. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | | TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE | | | SEC. 502 THRU 505. | | | | | | 9. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | | | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-03-29 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-03-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-03-11 |
Time |
10:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-03-03 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-03-03 |
Time |
11:19 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-02-19 |
Time |
09:56 |
Sent To |
|
|
| Notes |
| 2016-03-03 11:27:01 | 3/3/16 FAILED THE LAST OF ALL MP REVIEWS. CONTRACTOR | | | NOTIFIED VIA EMAIL. SENT FILE TO LARGE DENIED BIN "A". | | | MA | | 2016-02-22 09:56:58 | C20 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-01-21 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-01-21 |
Time |
19:01 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-12-17 |
Time |
11:09 |
Sent To |
|
|
| Notes |
| 2016-01-21 19:02:59 | 1/21/16 FAILED THE LAST OF ALL TRADE REVIEWS | | | (ELECTRICAL). CONTRACTOR NOTIFIED VIA EMAIL. SENT FILE | | | TO LARGE DENIED DRAWER "A". MA | | 2015-12-18 11:10:59 | C20 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2016-03-30 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-03-30 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-03-30 |
Time |
16:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2016-03-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-03-21 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-03-21 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2016-03-21 10:51:33 | 3RD REVIEW: FBC 2014 MECHANICAL | | | PERMIT #15120611 | | | 3/21/16 | | | | | | 1) IT APPEARS THE PLAN SHEET M6.2 IS MISSING FROM THE | | | PLAN SETS, AND ALSO THE AC LOAD CALCULATIONS ARE NOT IN | | | THE PERMIT FILE. PLEASE RE-SUBMIT THE REQUIRED PLANS | | | AND DOCUMENTS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2016-02-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-02-29 |
Time |
11:01 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-02-26 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2016-03-01 11:04:15 | 3RD REVIEW: FBC 2014 MECHANICAL | | | PERMIT #15120611 | | | 2/29/16 | | | | | | 1) SUBMIT PLANS SHEET M2.2 AS INDICATED IN THE RESPONSE | | | NARRATIVE FROM KAMM ENGINEERING. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-12-28 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-12-28 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-12-28 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2015-12-28 14:35:09 | 1ST REVIEW 2014 MECHANICAL | | | PERMIT #15120611 | | | 12/28/15 | | | | | | 1) SHEET M2.1: OUTDOOR AIR IS BEING SUPPLIED ONLY TO | | | THE CENTRAL DINING AREA VIA OARTU-1, HOWEVER NO O/A IS | | | BEING SUPPLIED TO THE KITCHEN, THE PRIVATE DINING AREA, | | | THE UPPER DINING AREAS, AND THE BACK BAR AREA THROUGH | | | AHU'S 1, 2, & 3. PLEASE REFER TO TABLE 403.3 FBC-14 | | | MECHANICAL AND REVISE THE PLANS TO SHOW COMPLIANCE. | | | 2) M2.1: DUCT SMOKE DETECTORS ARE REQUIRED TO BE | | | INSTALLED IN THE RETURN AIR SYSTEMS OF AHU'S 1, 2, & 3- | | | SEE SECTION 606.2.1. | | | 3) PROVIDE A CHILLED WATER PIPING LAYOUT PLAN WITH PIPE | | | AND PIPE INSULATION DETAILS. | | | 4) PROVIDE A HVAC ROOF PLAN SHOWING THE LOCATIONS OF | | | THE OARTU-1, THE AC AND REFRIGERATION CONDENSERS, AND | | | THE KITCHEN HOOD EXHAUST AND SUPPLY FANS. PLEASE | | | INCLUDE CLEARANCES DISTANCES AS OUTLINED IN SECTIONS | | | 401.4 AND 501.3.1 FBC-14 MECHANICAL. | | | 5) PROVIDE ENGINEERED TIE DOWN DETAILS FOR THE OARTU-1 | | | AND THE AC CONDENSERS. | | | 6) PLACE A NOTE ON THE PLANS INDICATING THE KITCHEN | | | HOODS, AND WALK-IN COOLER WILL BE DONE UNDER SEPARATE | | | PERMITS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2016-03-16 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-03-16 |
Time |
17:40 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-03-16 |
Time |
17:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2016-02-28 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2016-02-28 |
Time |
06:59 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2016-02-28 |
Time |
05:32 |
Sent To |
|
|
| Notes |
| 2016-02-28 06:29:11 | 1) SHT. A-8 - THE EQUIPMENT SCHEDULE SHOWS GAS TO | | | EQUIPMENT NUMBERS E96, E99, E106 & E117. THIS HAS BEEN | | | CORRECTED ON THE EQUIPMENT SCHEDULE IN THE PLUMBING | | | DRAWINGS AND ALSO NEEDS TO BE CORRECTED ON THIS SHEET. | | | 2) SHOW THE CAPACITY OF THE EXISTING GREASE INTERCEPTOR | | | AND SUBMIT GREASE WASTE CALCULATIONS TO ENSURE THE | | | EXISTING GREASE TRAP HAS THE CAPACITY TO PERFORM AS | | | DESIGNED.FBC SEC. 107.2.1. | | | 3) THE TWO FLOOR SINKS & FLOOR DRAIN LOCATED IN THE | | | ROOM WITH THE WATER HEATEER AND THE EXISTING MOP SINK | | | ARE NOT VENTED. COMPLY WITH 2014 FPC SEC. 910 OR 914. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-01-04 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-01-04 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-01-04 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2016-01-04 11:52:13 | 1ST REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHEET P5.1 GREASE RISER FOR BACK BAR AREA, EACH | | | FIXTURE BRANCH SHALL CONNECT SEPARATELY TO HORIZONTALL | | | BRANCH SHALL COMPLY WITH FBC P SEC 914 | | | 2. SHEET P5.1 GREASE RISER FOR KITCHEN AREA, EACH | | | FIXTURE BRANCH MUST CONNECT TO A VENTED HORIZONTA | | | BRANCH IT CAN NOT CONNECT TO BUILD DRAIN WITH OUT BEING | | | VENTED. SHALL COMPLY WITH FBC PL SEC 910.1 OR 914 | | | 3. SHOW BACKFLOW DEVICE ON RISER DIGRAM FOR FIXTURES | | | THAT REQUIRE A SEPARATE BACKFLOW PER WPB AMEND. TO FBC | | | SEC107.2.1 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2016-03-15 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2016-03-15 |
Time |
14:52 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2016-03-15 |
Time |
14:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2016-02-29 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2016-02-29 |
Time |
10:42 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2016-02-29 |
Time |
10:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2016-01-06 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2016-01-06 |
Time |
13:21 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2016-01-06 |
Time |
13:21 |
Sent To |
|
|
| Notes |
|
|