Plan Review Details - Permit 15120581
| Plan Review Stops For Permit 15120581 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2015-12-30 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2015-12-30 |
Time |
06:30 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2015-12-30 |
Time |
06:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-02-10 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-02-10 |
Time |
09:01 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-02-10 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2016-02-10 09:02:16 | DISREGARD PREVIOUS ELECTRICAL COMMENT AS DESCRIPTION IS | | | CHANGED TO DEMO. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-01-27 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-01-27 |
Time |
17:36 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-01-27 |
Time |
16:15 |
Sent To |
I |
|
| Notes |
| 2016-01-27 17:40:05 | YOU ARE APPROVED FOR THE DEMOLITION PORTION OF THIS | | | PERMIT BUT THE RENOVATION SHALL COMPLY WITH THE | | | FOLLOWING. YOU SHALL SUBMIT A COMPLETE SET OF | | | ELECTRICAL PLANS FOR THE INTERIOR RENOVATION. THE | | | DRAWINGS SUBMITTED ARE ONLY FOR THE DEMOLITION PHASE OF | | | THE PROJECT AND ITS RESPECTIVE PERMIT (16010826). THIS | | | PLAN SHALL INCLUDE A POWER PLAN, A LIGHTING PLAN | | | INCLUSIVE OF LIGHTING CONTROL AND A ALLOWABLE LIGHT | | | DENSITY CHART, A RISER DIAGRAM, A PANEL SCHEDULE, AND | | | EVERY OTHER USUAL AND CUSTOMARY INCLUSION OF AN | | | ELECTRICAL PLAN. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2015-12-22 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-12-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-12-22 |
Time |
12:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-01-27 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-01-27 |
Time |
17:42 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-12-17 |
Time |
12:42 |
Sent To |
|
|
| Notes |
| 2016-01-27 17:43:10 | 1/27/16 FAILED ELECTRICAL REVIEW AS NOTED. CONTRACTOR | | | NOTIFIED VIA EMAIL. SENT FILE TO LARGE DENIED BIN "H". | | | MA | | 2015-12-17 12:42:30 | B08 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2015-12-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-12-23 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-12-23 |
Time |
10:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2015-12-20 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-12-20 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-12-20 |
Time |
11:36 |
Sent To |
|
|
| Notes |
|
|
|