Plan Review Details - Permit 15120538
| Plan Review Stops For Permit 15120538 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2016-01-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-01-19 |
Time |
17:47 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-01-19 |
Time |
17:47 |
Sent To |
|
|
| Notes |
| 2016-01-19 17:56:01 | RE-ROOF SECOND BUILDING REVIEW CHECKLIST. | | | CODE: FBC-5TH EDITION (2014). | | | | | | 1- ENGINEER TO REVISE RAS 117 CALCULATIONS SUBMITTED: | | | A) ACCORDING TO SECTION 8.1 OF RAS 117 "THE MINIMUM | | | FASTENER SEPARATION SHALL NOT BE LESS THAN 4 IN. O.C." | | | . ENGINEER SUBMITTED SOME RAS 117 CALCULATIONS WITH | | | FASTENER SPACING LESS THAN 4 IN. O.C. REVISE AS | | | REQUIRED TO COMPLY WITH SEC. 8.1. | | | | | | | | | NOTE: | | | ANY A/C UNITS REMOVAL, PROPOSED 8 NEW SKYLIGHTS, | | | RETROFIT AND NEW ROOF DRAINS, ELECTRICAL WORK, ETC. | | | REQUIRE COMPLETE INFORMATION UNDER SEPARATE PERMITS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-01-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-01-14 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-01-14 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2016-01-14 07:54:45 | RE-ROOF SECOND BUILDING REVIEW CHECKLIST. | | | CODE: FBC-5TH EDITION (2014). | | | | | | 1- ENGINEER TO REVISE RAS 117 CALCULATIONS SUBMITTED: | | | A) ACCORDING TO SECTION 8.1 OF RAS 117 "THE MINIMUM | | | FASTENER SEPARATION SHALL NOT BE LESS THAN 4 IN. O.C." | | | . ENGINEER SUBMITTED SOME RAS 117 CALCULATIONS WITH | | | FASTENER SPACING LESS THAN 4 IN. O.C. REVISE AS | | | REQUIRED TO COMPLY WITH SEC. 8.1. | | | | | | | | | NOTE: | | | ANY A/C UNITS REMOVAL, PROPOSED 8 NEW SKYLIGHTS, | | | RETROFIT AND NEW ROOF DRAINS, ELECTRICAL WORK, ETC. | | | REQUIRE COMPLETE INFORMATION UNDER SEPARATE PERMITS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-12-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2015-12-16 |
Time |
17:13 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2015-12-16 |
Time |
17:05 |
Sent To |
|
|
| Notes |
| 2015-12-16 17:13:32 | RE-ROOF BUILDING REVIEW COMMENTS. | | | CODE: FBC-5TH EDITION (2014). | | | | | | 1- ROOF ASSEMBLIES WITH MECHANICAL ATTACHMENT NEED | | | FASTENER PULL OUT TEST (TAS 105) AS REQUIRED BY | | | LIGHTWEIGHT CONCRETE DECK SYSTEM LIMITATION #1 AND BY | | | GENERAL LIMITATION #6 ON LAST PAGE OF NOA 15-1008.02 | | | SUBMITTED. PROVIDE 2 COMPLETE TAS 105 PULL OUT TEST | | | REPORTS. NOTE: ENGINEER TO REVISE RAS 117 CALCULATIONS | | | ACCORDINGLY. | | | | | | 2- ENGINEER TO REVISE RAS 117 CALCULATIONS SUBMITTED: | | | A) THE BUILDING RISK CATEGORY IS INCORRECT. THIS | | | BUILDING IS I-3, THEREFORE THE RISK CATEGORY IS III NOT | | | II. REVISE AS AS REQUIRED. SEE TABLE 1604.5 OF FBC-5TH | | | EDITION (2014). ALSO, REVISE DESIGN WIND SPEED AND ALL | | | DESIGN PRESSURES AS REQUIRED BY FIGURE 1609B OF FBC-5TH | | | EDITION (2014). | | | | | | B) CLARIFY WHY THE ENCLOSURE CLASS IS OPEN. SEC. 1609 | | | OF FBC-5TH EDITION (2014). | | | | | | NOTE: | | | ANY A/C UNITS REMOVAL, PROPOSED 8 NEW SKYLIGHTS, | | | RETROFIT AND NEW ROOF DRAINS, ELECTRICAL WORK, ETC. | | | REQUIRE COMPLETE INFORMATION UNDER SEPARATE PERMITS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-01-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-01-19 |
Time |
17:47 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-01-15 |
Time |
15:02 |
Sent To |
|
|
| Notes |
| 2016-01-19 15:02:56 | RESUB ROUTED TO JGOMEZ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-01-14 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2016-01-14 |
Time |
07:54 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2016-01-08 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2016-01-08 11:24:59 | RESUB ROUTED JGOMEZ |
|
|
|