| Plan Review Stops For Permit 15120533 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-05-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-05-04 |
Time |
08:43 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-05-04 |
Time |
08:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-01-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2016-01-19 |
Time |
13:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2016-01-19 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2016-01-19 13:45:53 | CHRISTOPHER S. THROOP, C.B.O. | | | BLDG. PLANS EXAMINER ? PX3169 | | | (561) 805-6718 | | | [email protected] | | | | | | PROVIDE ENERGY CALCS. | | | PROVIDE DETAIL FOR LOAD BEARING WALL OPENINGS. | | | PROVIDE PRODUCT APPROVALS FOR NEW WINDOWS AND DOORS, | | | (INCLUDE PRODUCT APPROVALS FOR WINDOW MULLIONS). | | | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND | | | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM | | | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, | | | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE | | | TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC, | | | AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE | | | OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS | | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | | INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | | SECTION 107.3.5). | | | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW, AND DOOR SUBMITTALS. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-04-25 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-04-25 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-04-25 |
Time |
12:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-01-20 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2016-01-20 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2016-01-20 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2016-01-20 10:43:36 | JOB PERMIT NUMBER: 15120533 | | | JOB ADDRESS: 215 MARLBOROUGH RD | | | WEST PALM BEACH 33405 | | | DATE: JAN 20, 2016 | | | ELECTRICAL PLAN REVIEW COMMENTS | | | THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION | | | HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF | | | THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC, | | | (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST | | | PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF | | | SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED. | | | | | | 1- PLEASE PROVIDE A RISER DIAGRAM AND LOAD CALCULATIONS | | | . FBC- 107.3.5.3 ? ELECTRIC SERVICE RISER WITH WIRE | | | SIZES, CONDUIT DETAIL AND GROUNDING DETAIL. COMPLETE | | | LOAD CALCULATIONS, PANEL SCHEDULES AND SHOW CIRCUITS ON | | | FLOOR PLAN. | | | 2- MISSING GFCI SERVICE RECEPTACLE FOR CU-1. FBC-R E | | | 390.11 - PROVIDE A GFI SERVICE OUTLET FOR WITHIN 25? OF | | | MECHANICAL EQUIPMENT. | | | 3- MISSING LIGHTING OUTLET BY ATTIC ENTRANCE TO SERVICE | | | HVAC EQUIPMENT. FBC-R E3903.4 | | | 4- PERMANENT LADDERS OR STAIRWAYS SHALL BE PROVIDED TO | | | GIVE SAFE ACCESS TO THE WORKING SPACE AROUND ELECTRICAL | | | EQUIPMENT INSTALLED IN ATTICS. NEC 110.33 B | | | PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE | | | MENTIONED DEFICIENCIES. | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | | RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE | | | LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE | | | STANDARD CITY RE-SUBMITTAL FORM. THE NARRATIVE SHOULD | | | INCLUDE THE PLAN REVIEWER?S COMMENTS AND YOUR RESPONSE | | | OR ACTION TO SAME. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE | | | PREVIOUSLY REVIEWED SHEETS FOR COMPARISON. | | | CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | 1ST REVIEW: FBC 2014 5TH ED. NEC 2011/RESIDENTIAL | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 516-805-6700 | | | [email protected] | | | ALTERNATE CONTACT | | | MIKE ALBARRAN | | | 561-805-6746 | | | [email protected] | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
P |
Date |
2016-05-04 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2016-05-04 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2016-05-04 |
Time |
14:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-12-23 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-12-23 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-12-23 |
Time |
14:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-05-04 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2016-05-04 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2016-04-21 |
Time |
14:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-01-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-01-29 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2015-12-15 |
Time |
14:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2016-04-25 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-04-25 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-04-25 |
Time |
10:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-01-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-01-29 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-01-29 |
Time |
10:05 |
Sent To |
|
|
| Notes |
| 2016-01-29 10:17:42 | 1ST REVIEW: FBC 2014 MECHANICAL | | | PERMIT 315120533 | | | 1/29/16 | | | | | | 1) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE | | | NEW SYSTEMS ON THE SECOND FLOOR AND IN THE COTTAGE- SEE | | | SECTION R403.6 FBC-14 ENERGY CONSERVATION. | | | 2) PLEASE REVIEW SECTION R403.2.4 FBC-14 ENERGY | | | CONSERVATION IN REGARD TO AHU-1 IN THE ATTIC, AND | | | SUBMIT PERFORMANCE BASED ENERGY CALCULATIONS AND REVISE | | | THE PLAN TO SHOW COMPLIANCE: R403.2.4 AIR-HANDLING | | | UNITS. | | | AIR HANDLING UNITS SHALL NOT BE INSTALLED IN THE ATTIC | | | WHEN A HOME IS BROUGHT INTO CODE COMPLIANCE BY SECTION | | | R402. AIR-HANDLING UNITS SHALL BE ALLOWED IN ATTICS FOR | | | COMPLIANCE BY SECTION R405 ONLY IF THE FOLLOWING | | | CONDITIONS ARE MET: | | | 1. THE SERVICE PANEL OF THE EQUIPMENT IS LOCATED WITHIN | | | 6 FEET (1829 MM) OF AN ATTIC ACCESS. | | | 2. A DEVICE IS INSTALLED TO ALERT THE OWNER OR SHUT THE | | | UNIT DOWN WHEN THE CONDENSATION DRAIN IS NOT WORKING | | | PROPERLY. | | | 3. THE ATTIC ACCESS OPENING IS OF SUFFICIENT SIZE TO | | | REPLACE THE AIR HANDLER. | | | 4. A NOTICE IS POSTED ON THE ELECTRIC SERVICE PANEL | | | INDICATING TO THE HOMEOWNER THAT THE AIR HANDLER IS | | | LOCATED IN THE ATTIC. SAID NOTICE SHALL BE IN ALL | | | CAPITALS, IN 16 POINT TYPE, WITH THE TITLE AND FIRST | | | PARAGRAPH IN BOLD: | | | NOTICE TO HOMEOWNER | | | A PART OF YOUR AIR-CONDITIONING SYSTEM, THE AIR | | | HANDLER, IS LOCATED IN THE ATTIC. FOR PROPER, | | | EFFICIENT, AND ECONOMIC OPERATION OF THE | | | AIR-CONDITIONING SYSTEM, YOU MUST ENSURE THAT REGULAR | | | MAINTENANCE IS PERFORMED. YOUR AIR-CONDITIONING SYSTEM | | | IS EQUIPPED WITH ONE OR BOTH OF THE FOLLOWING: (1) A | | | DEVICE THAT WILL ALERT YOU WHEN THE CONDENSATION DRAIN | | | IS NOT WORKING PROPERLY OR (2) A DEVICE THAT WILL SHUT | | | THE SYSTEM DOWN WHEN THE CONDENSATION DRAIN IS NOT | | | WORKING. TO LIMIT POTENTIAL DAMAGE TO YOUR HOME, AND TO | | | AVOID DISRUPTION OF SERVICE, IT IS RECOMMENDED THAT YOU | | | ENSURE PROPER WORKING ORDER OF THESE DEVICES BEFORE | | | EACH SEASON OF PEAK OPERATION. | | | 3) THE 8" TRANSFER DUCTS FROM BEDROOM 2 & 3 ARE | | | UNDERSIZED PER SECTION M1602.4. PLEASE PROVIDE MINIMUM | | | 9" DUCTS FOR COMPLIANCE. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2016-04-25 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-04-25 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-04-25 |
Time |
10:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-12-29 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2015-12-29 |
Time |
07:38 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2015-12-29 |
Time |
07:38 |
Sent To |
|
|
| Notes |
| 2015-12-29 07:51:18 | 1ST REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | | | | 1. SHEET P101 SANITARY RISER IT APPEARS THAT THE 11/2 | | | WASTE ARM FOR THE LAV IN MASTER BATH EXCEEDS 6FT IT | | | MUST COMPLY WITH FBCP SEC 909.1 OR 910.1 INDIVIDUAL | | | VENT PERMITTED. | | | 2. PLEASE SHOW DEMENTIONS OF MASTER BATHROOM AND NEW | | | BATHROOM IN COTTAGE. PER WPB AMEND TO FBC SEC 107.2.1 | | | 3.SHEET P101 THE RISER DIAGRAM AND PIPING ON FLOOR PLAN | | | DON'T MATCH FOR MASTER BATH. PLEASE CORRECT PER WPB | | | AMEND TO FBC 107.2.1 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2016-05-04 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2016-05-04 |
Time |
14:24 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2016-05-04 |
Time |
14:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2015-12-23 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2015-12-23 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2015-12-23 |
Time |
14:31 |
Sent To |
B |
|
| Notes |
|
|