Plan Review Details - Permit 15120533
Plan Review Stops For Permit 15120533
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-05-04 Cont ID  
Sent By cthroop Date 2016-05-04 Time 08:43 Rev Time 0.00
Received By cthroop Date 2016-05-04 Time 08:43 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-01-19 Cont ID  
Sent By cthroop Date 2016-01-19 Time 13:41 Rev Time 0.00
Received By cthroop Date 2016-01-19 Time 13:41 Sent To  
Notes
2016-01-19 13:45:53CHRISTOPHER S. THROOP, C.B.O.
 BLDG. PLANS EXAMINER ? PX3169
 (561) 805-6718
 [email protected]
  
 PROVIDE ENERGY CALCS.
 PROVIDE DETAIL FOR LOAD BEARING WALL OPENINGS.
 PROVIDE PRODUCT APPROVALS FOR NEW WINDOWS AND DOORS,
 (INCLUDE PRODUCT APPROVALS FOR WINDOW MULLIONS).
  
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND
 SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM
 OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS,
 WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE
 TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC,
 AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE
 OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5).
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE WINDOW, AND DOOR SUBMITTALS.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-04-25 Cont ID  
Sent By mvaldes Date 2016-04-25 Time 12:58 Rev Time 0.00
Received By mvaldes Date 2016-04-25 Time 12:58 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-01-20 Cont ID  
Sent By mvaldes Date 2016-01-20 Time 10:42 Rev Time 0.00
Received By mvaldes Date 2016-01-20 Time 10:41 Sent To  
Notes
2016-01-20 10:43:36JOB PERMIT NUMBER: 15120533
 JOB ADDRESS: 215 MARLBOROUGH RD
 WEST PALM BEACH 33405
 DATE: JAN 20, 2016
  ELECTRICAL PLAN REVIEW COMMENTS
 THE PLANS FOR THE ABOVE MENTIONED PERMIT APPLICATION
 HAVE BEEN REVIEWED FOR COMPLIANCE WITH THE EDITION OF
 THE NEC, (NATIONAL ELECTRICAL CODE) AND THE FBC,
 (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST
 PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF
 SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED.
  
 1- PLEASE PROVIDE A RISER DIAGRAM AND LOAD CALCULATIONS
 . FBC- 107.3.5.3 ? ELECTRIC SERVICE RISER WITH WIRE
 SIZES, CONDUIT DETAIL AND GROUNDING DETAIL. COMPLETE
 LOAD CALCULATIONS, PANEL SCHEDULES AND SHOW CIRCUITS ON
 FLOOR PLAN.
 2- MISSING GFCI SERVICE RECEPTACLE FOR CU-1. FBC-R E
 390.11 - PROVIDE A GFI SERVICE OUTLET FOR WITHIN 25? OF
 MECHANICAL EQUIPMENT.
 3- MISSING LIGHTING OUTLET BY ATTIC ENTRANCE TO SERVICE
 HVAC EQUIPMENT. FBC-R E3903.4
 4- PERMANENT LADDERS OR STAIRWAYS SHALL BE PROVIDED TO
 GIVE SAFE ACCESS TO THE WORKING SPACE AROUND ELECTRICAL
 EQUIPMENT INSTALLED IN ATTICS. NEC 110.33 B
 PLEASE REVISE YOUR DRAWINGS TO REFLECT THE ABOVE
 MENTIONED DEFICIENCIES.
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE
 LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE
 STANDARD CITY RE-SUBMITTAL FORM. THE NARRATIVE SHOULD
 INCLUDE THE PLAN REVIEWER?S COMMENTS AND YOUR RESPONSE
 OR ACTION TO SAME. ADDITIONALLY, PLEASE INSERT
 CORRECTED PAGES INTO THE SUBMITTAL AND LEAVE THE
 PREVIOUSLY REVIEWED SHEETS FOR COMPARISON.
 CLOUDING THE CHANGES WILL BE GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 1ST REVIEW: FBC 2014 5TH ED. NEC 2011/RESIDENTIAL
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 516-805-6700
 [email protected]
 ALTERNATE CONTACT
 MIKE ALBARRAN
 561-805-6746
 [email protected]
  
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2016-05-04 Cont ID  
Sent By fmittner Date 2016-05-04 Time 14:23 Rev Time 0.00
Received By fmittner Date 2016-05-04 Time 14:23 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2015-12-23 Cont ID  
Sent By fmittner Date 2015-12-23 Time 14:30 Rev Time 0.00
Received By fmittner Date 2015-12-23 Time 14:30 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-05-04 Cont ID  
Sent By cpuell Date 2016-05-04 Time 14:37 Rev Time 0.00
Received By cpuell Date 2016-04-21 Time 14:14 Sent To  
Notes
2016-04-21 14:14:53R26

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-01-29 Cont ID  
Sent By ccole Date 2016-01-29 Time 10:17 Rev Time 0.00
Received By ccole Date 2015-12-15 Time 14:56 Sent To  
Notes
2015-12-23 14:56:36R02

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2016-04-25 Cont ID  
Sent By skennedy Date 2016-04-25 Time 10:03 Rev Time 0.00
Received By skennedy Date 2016-04-25 Time 10:03 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-01-29 Cont ID  
Sent By ccole Date 2016-01-29 Time 10:05 Rev Time 0.00
Received By ccole Date 2016-01-29 Time 10:05 Sent To  
Notes
2016-01-29 10:17:421ST REVIEW: FBC 2014 MECHANICAL
 PERMIT 315120533
 1/29/16
  
 1) PROVIDE AC COOLING AND HEATING CALCULATIONS FOR THE
 NEW SYSTEMS ON THE SECOND FLOOR AND IN THE COTTAGE- SEE
 SECTION R403.6 FBC-14 ENERGY CONSERVATION.
 2) PLEASE REVIEW SECTION R403.2.4 FBC-14 ENERGY
 CONSERVATION IN REGARD TO AHU-1 IN THE ATTIC, AND
 SUBMIT PERFORMANCE BASED ENERGY CALCULATIONS AND REVISE
 THE PLAN TO SHOW COMPLIANCE: R403.2.4 AIR-HANDLING
 UNITS.
 AIR HANDLING UNITS SHALL NOT BE INSTALLED IN THE ATTIC
 WHEN A HOME IS BROUGHT INTO CODE COMPLIANCE BY SECTION
 R402. AIR-HANDLING UNITS SHALL BE ALLOWED IN ATTICS FOR
 COMPLIANCE BY SECTION R405 ONLY IF THE FOLLOWING
 CONDITIONS ARE MET:
 1. THE SERVICE PANEL OF THE EQUIPMENT IS LOCATED WITHIN
 6 FEET (1829 MM) OF AN ATTIC ACCESS.
 2. A DEVICE IS INSTALLED TO ALERT THE OWNER OR SHUT THE
 UNIT DOWN WHEN THE CONDENSATION DRAIN IS NOT WORKING
 PROPERLY.
 3. THE ATTIC ACCESS OPENING IS OF SUFFICIENT SIZE TO
 REPLACE THE AIR HANDLER.
 4. A NOTICE IS POSTED ON THE ELECTRIC SERVICE PANEL
 INDICATING TO THE HOMEOWNER THAT THE AIR HANDLER IS
 LOCATED IN THE ATTIC. SAID NOTICE SHALL BE IN ALL
 CAPITALS, IN 16 POINT TYPE, WITH THE TITLE AND FIRST
 PARAGRAPH IN BOLD:
 NOTICE TO HOMEOWNER
 A PART OF YOUR AIR-CONDITIONING SYSTEM, THE AIR
 HANDLER, IS LOCATED IN THE ATTIC. FOR PROPER,
 EFFICIENT, AND ECONOMIC OPERATION OF THE
 AIR-CONDITIONING SYSTEM, YOU MUST ENSURE THAT REGULAR
 MAINTENANCE IS PERFORMED. YOUR AIR-CONDITIONING SYSTEM
 IS EQUIPPED WITH ONE OR BOTH OF THE FOLLOWING: (1) A
 DEVICE THAT WILL ALERT YOU WHEN THE CONDENSATION DRAIN
 IS NOT WORKING PROPERLY OR (2) A DEVICE THAT WILL SHUT
 THE SYSTEM DOWN WHEN THE CONDENSATION DRAIN IS NOT
 WORKING. TO LIMIT POTENTIAL DAMAGE TO YOUR HOME, AND TO
 AVOID DISRUPTION OF SERVICE, IT IS RECOMMENDED THAT YOU
 ENSURE PROPER WORKING ORDER OF THESE DEVICES BEFORE
 EACH SEASON OF PEAK OPERATION.
 3) THE 8" TRANSFER DUCTS FROM BEDROOM 2 & 3 ARE
 UNDERSIZED PER SECTION M1602.4. PLEASE PROVIDE MINIMUM
 9" DUCTS FOR COMPLIANCE.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-04-25 Cont ID  
Sent By skennedy Date 2016-04-25 Time 10:03 Rev Time 0.00
Received By skennedy Date 2016-04-25 Time 10:03 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-12-29 Cont ID  
Sent By gjohnson Date 2015-12-29 Time 07:38 Rev Time 0.00
Received By gjohnson Date 2015-12-29 Time 07:38 Sent To  
Notes
2015-12-29 07:51:181ST REVIEW: FBC 2014
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
  
 1. SHEET P101 SANITARY RISER IT APPEARS THAT THE 11/2
 WASTE ARM FOR THE LAV IN MASTER BATH EXCEEDS 6FT IT
 MUST COMPLY WITH FBCP SEC 909.1 OR 910.1 INDIVIDUAL
 VENT PERMITTED.
 2. PLEASE SHOW DEMENTIONS OF MASTER BATHROOM AND NEW
 BATHROOM IN COTTAGE. PER WPB AMEND TO FBC SEC 107.2.1
 3.SHEET P101 THE RISER DIAGRAM AND PIPING ON FLOOR PLAN
 DON'T MATCH FOR MASTER BATH. PLEASE CORRECT PER WPB
 AMEND TO FBC 107.2.1

Review Stop Z ZONING
Rev No 2 Status P Date 2016-05-04 Cont ID  
Sent By fmittner Date 2016-05-04 Time 14:24 Rev Time 0.00
Received By fmittner Date 2016-05-04 Time 14:24 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2015-12-23 Cont ID  
Sent By fmittner Date 2015-12-23 Time 14:31 Rev Time 0.00
Received By fmittner Date 2015-12-23 Time 14:31 Sent To B
Notes
***NONE***