Plan Review Details - Permit 15120414
| Plan Review Stops For Permit 15120414 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2015-12-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-12-18 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-12-18 |
Time |
10:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-12-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-12-18 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-12-18 |
Time |
10:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2015-12-17 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-12-17 |
Time |
06:51 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-12-17 |
Time |
06:48 |
Sent To |
|
|
| Notes |
| 2015-12-17 06:51:01 | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | | FBC-R, SEC. G2404.3. | | | | | | PLUMBING PLAN REVIEW | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | 561-805-6692 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2015-12-11 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2015-12-11 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2015-12-11 |
Time |
11:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-12-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2015-12-18 |
Time |
10:59 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2015-12-11 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2015-12-11 14:20:18 | ROUTED TO ZONING |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2015-12-17 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2015-12-17 |
Time |
06:47 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2015-12-17 |
Time |
06:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2015-12-11 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2015-12-11 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2015-12-11 |
Time |
11:23 |
Sent To |
|
|
| Notes |
| 2015-12-11 11:23:21 | PROVISO | | | | | | EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE OR | | | SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT ACCESS | | | BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF THE | | | RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED. | | | BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN | | | HEIGHT ABOVE GRADE. | | | | | | ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE THROUGH A | | | BUILDING OR THROUGH A SELF-CLOSING AND SELF-LATCHING | | | GATE OR THROUGH A SCREEN ENCLOSURE DOOR WITH LATCHES | | | PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF GATE. AT | | | LEAST 90 PERCENT OF THE SURFACE AREA OF ALL SCREEN | | | ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH WHICH | | | AIR SHALL FLOW. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT | | | JOHN ROACH, PRINCIPAL PLANNER, AT | | | [email protected] OR (561) 822-1448. | | | |
|
|
|