Plan Review Details - Permit 15120344
Plan Review Stops For Permit 15120344
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-03-01 Cont ID  
Sent By jwitmer Date 2016-03-01 Time 15:36 Rev Time 0.00
Received By jwitmer Date 2016-03-01 Time 14:56 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-02-22 Cont ID  
Sent By jwitmer Date 2016-02-22 Time 12:00 Rev Time 0.00
Received By jwitmer Date 2016-02-22 Time 10:24 Sent To  
Notes
2016-02-22 12:00:42BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15120344
 MASTER: 15060045
 ADD: 2224 PALM BEACH LAKES BLVD.
 CONT: MACHIN MECHANICAL
 TEL: 954-702-3390
 E-MAIL:
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
  
 2ND REVIEW
 DATE: MON. FEB.22/2016
 ACTION: DENIED
  
 1-6) COMPLIED
  
 7) A REPORT SUBMITTED BY DOUGLAS RUGGIANO P.E. FOR THE
 WIND ANALYSIS AND STRUCTURAL CALCULATIONS FOR FASTENING
 REQUIREMENTS OF TRANE A/C ROOF TOP EQUIPMENT IS A
 COPIED REPORT DATED 8/02/12. THIS REPORT ONLY HAS THE
 COVERSHEET SEALED (COPY).
 PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS
 PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR
 PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE
 DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT.
 FL ADMIN CODE 61G15-23.002 ENGINEERS
 EFFECTIVE DATE 05/06/2009
 (2)(A) EVERY SHEET OF PLANS AND PRINTS WHICH MUST BE
 SEALED UNDER THE PROVISIONS OF CHAPTER 471, F.S., SHALL
 BE SEALED, SIGNED AND DATED BY THE PROFESSIONAL
 ENGINEER IN RESPONSIBLE CHARGE.
  
 61G15-23.002(2) FL. ADMIN. CODE. A COVER SHEET OR INDEX
 SHEET FOR ENGINEERING SPECIFICATIONS MAY BE USED AND
 THAT SHEET MUST BE SIGNED IN RESPONSIBLE CHARGE OF THE
 PRODUCTION & PREPARATION OF EACH SECTION OF THE
 ENGINEERING SPECIFICATION WITH SUFFICIENT INFORMATION
 ON THE COVER SHEET OR INDEX LISTING HOW MANY PAGES ARE
 COVERED UNDER THE COVER SHEET OR INDEX SHEET. .
  
 8) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-12-14 Cont ID  
Sent By jwitmer Date 2015-12-14 Time 16:44 Rev Time 0.00
Received By jwitmer Date 2015-12-14 Time   Sent To  
Notes
2015-12-14 16:44:05 
 BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15120344
 MASTER: 15060045
 ADD: 2224 PALM BEACH LAKES BLVD.
 CONT: MACHIN MECHANICAL
 TEL: 954-702-3390
 E-MAIL:
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
  
 1ST REVIEW
 DATE: MON. DEC. 21/2015
 ACTION: DENIED
  
 1) THE MASTER PERMIT ON SHEETS 39/72 M0.1 AND SHEET S-2
 SHEET 59/72 BOTH SHOW GENERIC CONNECTIONS OF THE ROOF
 TOP CURB UNITS. SUBMITTAL # 10 PAGE 17OF 36 SHOWS A
 ROOF TOP CURB TRANE U. S. DIMENSIONAL PLAN. NOTE THIS
 IS NOT A PRODUCT APPROVAL. FLORIDA DEPARTMENT OF
 COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 (31)
 SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT
 WILL REQUIRE PRODUCT APPROVALS:
 (31) (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP
 CURBS, ROOF TOP INTAKE AND EXHAUST FANS, AND PRODUCTS
 INTRODUCED AS A RESULT OF NEW TECHNOLOGY.
  
 2) 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA
 RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN WRITING BY
 THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL.
  
 3) DISCREPANCY IN PLANS. THE SHEET 40 OF 72 SHEET M0.2
 SHOWS THE ROOF TOP PACKAGED UNITS AS LENNOX MODELS
 WHERE AS THE PAPERWORK BEING SUBMITTED UNDER THIS
 REVIEW ARE TRANE ROOF TOP CURBS AND ROOF TOP PACKAGE
 UNITS. 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED, IT
 APPEARS A REVISION MAY BE REQUIRED?
  
 4) SUBMITTAL/ TRANSMITTAL # 11 IS FOR AAON ROOFTOP
 CURBS, THE COVERSHEET FOR THESE REPORTS WAS NOT
 INCLUDED IN THIS SUBMITTAL INDICATING THE REPORT IS A
 FLORIDA REPORT OR A MIAMI-DADE NOA? NEED TO IDENTIFY
 THE TESTING AGENCY AND PRODUCT APPROVAL NUMBER. THERE
 ARE VARIOUS REPORTS 10-AOI-0001, 15-2535 WHICH
 REPRESENT VARIOUS UNITS, PLEASE IDENTIFY THE REPORT TO
 THE UNIT. THE SECOND ISSUE WITHIN BOTH REPORTS
 TECHNICAL SHEET # 1 IDENTIFY THE CURB TYPE TYPE TIER
 1-4.
 TECHNICAL SHEET 5 IDENTIFY STEEL CLIP SCHEDULE STANDARD
 CURB VERSES HEAVY DUTY CURB. DETAIL 3 OF SHEET # 5 NOTE
 CLIP TYPE 1 & 2 MAY BE USED INTERCHANGEABLY WITH THIS
 DESIGN, SELECTION OF THE CLIP SHALL BE BY OTHERS, AGAIN
 IDENTIFY CLIP.
  
 5) EXHAUST FAN #6 SUBMITTAL/ TRANSMITTAL # 12 NOA-
 15-0729.19 TECHNICAL SHEET 1/3 PLEASE IDENTIFY THE
 MODEL AND CURB DIMENSIONS. PAGE 3 OF 3 PLEASE IDENTIFY
 MODEL, DECK TYPE AND AMOUNT OF FASTENERS FOR ANCHORING
 THE FANS CURB TO ROOF. 107.2.1.3 ADDITIONAL INFORMATION
 REQUIRED.
  
 6) FOR ALL 3 SUBMITTALS/ TRANSMITTALS THE MECHANICAL
 ENGINEER AFFIXED THEIR SHOP DRAWING STAMP OF APPROVALS,
 THE STRUCTURAL ENGINEER OF RECORD GERSHON KLIEGER SHOUD
 BE THE ENGINEER OF RECORD REVIEWING THESE SUBMITTALS
 SINCE THEY ARE COMPONENTS AND CLADDING AND DEAL WITH
 WIND.
  
 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-03-01 Cont ID  
Sent By jwitmer Date 2016-03-01 Time 15:36 Rev Time 0.00
Received By jwitmer Date 2016-03-01 Time 09:43 Sent To  
Notes
2016-03-01 09:43:24ROUTED TO CHRIS COLE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-02-22 Cont ID  
Sent By jwitmer Date 2016-02-22 Time 12:00 Rev Time 0.00
Received By jwitmer Date 2016-02-16 Time 10:17 Sent To  
Notes
2016-02-16 10:17:20RESUB ROUTED TO CCOLE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2015-12-14 Cont ID  
Sent By jwitmer Date 2015-12-14 Time 16:45 Rev Time 0.00
Received By jwitmer Date 2015-12-09 Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2016-03-01 Cont ID  
Sent By ccole Date 2016-03-01 Time 10:39 Rev Time 0.00
Received By ccole Date 2016-03-01 Time 10:39 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2016-02-17 Cont ID  
Sent By ccole Date 2016-02-17 Time 09:17 Rev Time 0.00
Received By ccole Date 2016-02-17 Time 09:17 Sent To  
Notes
2016-02-17 09:45:142ND REVIEW: FBC 2014 MECHANICAL
 PERMIT #15120344
 2/17/16
  
 1) AN ENGINEERING PACKAGE FOR INSTALLATION OF TRANE
 RTU'S HAS BEEN SUBMITTED WITH AN OUTDATED COPIED
 SIGNATURE AND SEAL FROM DOUGLAS RUGGIANO P.E. PLEASE
 NOTE THAT ALL ENGINEERING SUBMITTALS SHALL BE CURRENTLY
 DATED, AND BEAR THE ORIGINAL SIGNATURE AND SEAL OF THE
 ENGINEER OF RECORD- SECTION 61G15-23.002 FLORIDA
 ADMINISTRATIVE CODE. PLEASE CLARIFY WHICH STRUCTURAL
 ENGINEER IS THE EOR FOR TIE DOWN OF THE TRANE RTU'S-
 MR. RUGGIANO OR G.D. KLIEGER WHOSE SIGNATURE AND SEAL
 APPEARS ON THE REVISED STRUCTURAL DRAWINGS. THE
 MECHANICAL ENGINEERS- CREDO APPEAR TO BE ON BOARD WITH
 MR. RUGGIANO BY VIRTUE OF THEIR SHOP DRAWING APPROVAL
 STAMPS ON THE TRANE DOCS.
 2) A PERMIT APPLICATION AND SPECIFICATIONS FOR THE
 GLYCOL BEER CHILLER SYSTEMS HAS BEEN ATTACHED NOW TO
 THIS PERMIT, HOWEVER THERE IS NO VALUE SHOWN ON THE
 APPLICATION. PLEASE NOTE THE APPROVED PLANS FOR THE
 TWIN PEAKS RESTAURANT (PERMIT #15060045) SHOWS THE
 GLYCOL SYSTEM TO BE INSTALLED "BY OTHERS"- SEE SHEETS
 FS-2.1 AND M2.1. THE FOUR ROOF TOP CONDENSERS AND BEER
 RUN LINES ARE SHOWN FOR REFERENCE ONLY. IN ACCORDANCE
 WITH SECTION 109.3 WPB AMENDMENTS TO THE FBC-10
 BUILDING CODE, A TOTAL VALUE THAT INCLUDES LABOR,
 MATERIALS, AND EQUIPMENT SHALL BE PLACED ON THE
 APPLICATION. IF THE CONTRACTOR DOES NOT PROVIDE AN
 ACCURATE COST FOR THE PROJECT, THAN A VALUE WILL BE
 PLACED ON THE APPLICATION BASED ON CURRENT NATIONAL
 VALUATION TABLES, AND APPROPRIATE PERMITTING FEES WILL
 BE CHARGED.
 3) PROVIDE SITE SPECIFIC WIND LOAD TIE-DOWN ENGINEERING
 FOR THE FOUR GLYCOL SYSTEM CONDENSERS AND ROOF STANDS-
 SECTION 301.12 FBC-10 MECHANICAL.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-12-11 Cont ID  
Sent By ccole Date 2015-12-11 Time 07:08 Rev Time 0.00
Received By ccole Date 2015-12-11 Time 07:08 Sent To  
Notes
2015-12-11 07:30:091ST REVIEW 2014 MECHANICAL
 PERMIT SUBMITTAL #15120344
 MASTER #15060045
 12/11/15
  
 1) THE RTU SUBMITTAL IS FOR TRANE MODEL UNITS, HOWEVER
 LENNOX MODELS ARE SHOWN ON THE MAIN BUILDING PLANS.
 PROVIDE A SUBMITTAL FOR THE LENNOX MODELS, OR REVISE
 THE MAIN PLAN TO INDICATE TRANE MODELS.
 2) THE AAON SUBMITTAL INCLUDES FL. PRODUCT APPROVAL #
 WITH MULTIPLE CURB MODELS THAT HAVE TO BE MATCHED WITH
 THE UNIT MODEL SELECTED FOR INSTALLATION. THE EOR MUST
 MARKUP THE DOCUMENT INDICATING WHICH CURB (STANDARD OR
 HEAVY DUTY), AND WHICH ATTACHMENT CLIP HE IS SELECTING
 FOR INSTALLATION- SEE PAGE 5. PLEASE NOTE THAT THE RTU
 INSTALLATION DETAILS BY KLIEGER P.E THAT ARE SHOWN ON
 THE MAIN PLAN SHEET S-2 SHOW A DIFFERENT METHOD OF
 INSTALLATION, AND ARE NOT SPECIFIC TO THE SELECTED
 ROOFTOP UNITS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  
  