Plan Review Details - Permit 15120184
Plan Review Stops For Permit 15120184
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-02-01 Cont ID  
Sent By cthroop Date 2016-02-01 Time 10:02 Rev Time 0.00
Received By cthroop Date 2016-02-01 Time 10:02 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2016-01-21 Cont ID  
Sent By cthroop Date 2016-01-21 Time 14:05 Rev Time 0.00
Received By cthroop Date 2016-01-21 Time 14:05 Sent To  
Notes
2016-01-21 14:26:40CHRISTOPHER S. THROOP, C.B.O.
 BLDG. PLANS EXAMINER ? PX3169
 (561) 805-6718
 [email protected]
  
 PROVIDE ROUGH OPENING DEMENSIONS FOR WINDOWS AND DOORS
 ON FLOOR PLAN.
 PROVIDE DOOR SCHEDULE.
 PROVIDE PRODUCT APPROVAL FOR PROPOSED ROOF SHINGLES.
 SUBMIT APPLICATION FOR ROOFING PERMIT.
  
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES
 SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE
 TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE
 FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE
 DESIGN. (SEE ALSO SECTION 107.3.5).
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2016-01-13 Cont ID  
Sent By cthroop Date 2016-01-13 Time 11:34 Rev Time 0.00
Received By cthroop Date 2016-01-13 Time 11:34 Sent To  
Notes
2016-01-13 11:50:20CHRISTOPHER S. THROOP, C.B.O.
 BLDG. PLANS EXAMINER ? PX3169
 (561) 805-6718
 [email protected]
  
 SUBMIT PERMIT APPLICATION FOR ROOFING SYSTEM.
 PROVIDE DOOR SCHEDULE.
 PROVIDE SOILS REPORT.
 PROVIDE PRODUCT APPROVAL FOR HARDIE SIDING.
 DEMONSTRATE COMPLIANCE WITH BUILDING THERMAL ENVELOPE
 REQUIREMENTS.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE EXTERIOR CLADDING SUBMITTALS.
 FBCE-103.2.1.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM 402
 SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO
 DEMONSTRATE CODE COMPLIANCE BY THIS METHOD.
  
 FBCE-103.2.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM 405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 R403.1 GENERAL.
 ALL EXTERIOR WALLS SHALL BE SUPPORTED ON CONTINUOUS
 SOLID OR FULLY GROUTED MASONRY OR CONCRETE FOOTINGS,
 CRUSHED STONE FOOTINGS, WOOD FOUNDATIONS, OR OTHER
 APPROVED STRUCTURAL SYSTEMS WHICH SHALL BE OF
 SUFFICIENT DESIGN TO ACCOMMODATE ALL LOADS ACCORDING TO
 SECTION R301 AND TO TRANSMIT THE RESULTING LOADS TO THE
 SOIL WITHIN THE LIMITATIONS AS DETERMINED FROM THE
 CHARACTER OF THE SOIL. FOOTINGS SHALL BE SUPPORTED ON
 UNDISTURBED NATURAL SOILS OR ENGINEERED FILL. CONCRETE
 FOOTING SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE
 WITH THE PROVISIONS OF SECTION R403 OR IN ACCORDANCE
 WITH ACI 332.
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-02-01 Cont ID  
Sent By mvaldes Date 2016-02-01 Time 12:58 Rev Time 0.00
Received By mvaldes Date 2016-02-01 Time 12:58 Sent To  
Notes
2016-02-01 13:01:47FBC 2014 5TH ED. NEC 2011/RESIDENTIAL
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 516-805-6700
 [email protected]
 ALTERNATE CONTACT
 MIKE ALBARRAN
 561-805-6746
 [email protected]
  
  
 PASSED WITH A PROVISO :
  
 - SMOKE ALARMS REQUIRED PER RESIDENTIAL CODE SECTIONS
 314 & 315
 - GROUNDING OF SYSTEM TO INCLUDE 2 GROUNDING ELECTRODES
 AND INTERSYSTEM BONDING.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-01-25 Cont ID  
Sent By skennedy Date 2016-01-25 Time 12:16 Rev Time 0.00
Received By skennedy Date 2016-01-25 Time 12:16 Sent To  
Notes
2016-01-25 12:17:59APPLICANT HAS AGREED TO RESUBMIT BASED ON COUNTER
 DISCUSSION.

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2016-01-11 Cont ID  
Sent By fmittner Date 2016-01-11 Time 11:15 Rev Time 0.00
Received By fmittner Date 2016-01-11 Time 11:15 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-02-05 Cont ID  
Sent By jgomez Date 2016-02-05 Time 13:54 Rev Time 0.00
Received By jgomez Date 2016-01-25 Time 11:21 Sent To  
Notes
2016-01-26 11:22:01R21

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-01-25 Cont ID  
Sent By skennedy Date 2016-01-25 Time 12:19 Rev Time 0.00
Received By skennedy Date 2015-12-04 Time 10:14 Sent To  
Notes
2015-12-06 10:14:38R03

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2016-02-09 Cont ID  
Sent By jgomez Date 2016-02-09 Time 08:25 Rev Time 0.00
Received By jgomez Date 2016-02-09 Time 08:07 Sent To  
Notes
2016-02-09 08:26:32$180.65 PAID. MU-2016-2865.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2016-01-20 Cont ID  
Sent By skennedy Date 2016-01-20 Time 12:10 Rev Time 0.00
Received By skennedy Date 2016-01-20 Time 12:10 Sent To  
Notes
2016-01-20 12:11:20PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE PLAN AND
 TAKE TO THAT OFFICE FOR REVIEW. PLEASE RETURNED STAMPED
 WITH A COPY OF RECEIPT AS APPLICABLE.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2016-02-08 Cont ID  
Sent By jgomez Date 2016-02-09 Time 13:54 Rev Time 0.00
Received By jgomez Date 2016-02-09 Time 08:06 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-01-25 Cont ID  
Sent By skennedy Date 2016-01-25 Time 12:18 Rev Time 0.00
Received By skennedy Date 2016-01-25 Time 12:18 Sent To  
Notes
2016-01-25 12:19:04APPLICANT HAS AGREED TO RESUBMIT BASED ON COUNTER
 DISCUSSION.

Review Stop P PLUMBING
Rev No 3 Status P Date 2016-01-30 Cont ID  
Sent By tklarge Date 2016-01-30 Time 07:47 Rev Time 0.00
Received By tklarge Date 2016-01-30 Time 07:28 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2016-01-22 Cont ID  
Sent By tklarge Date 2016-01-22 Time 15:05 Rev Time 0.00
Received By tklarge Date 2016-01-22 Time 14:52 Sent To  
Notes
2016-01-22 15:05:38THE COMMENTS FROM THE REVIEW ON 12/10/16 HAVE NOT BEEN
 ADDRESSED. COMPLY WITH ALL PREVIOUS COMMENTS.

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-12-10 Cont ID  
Sent By gjohnson Date 2015-12-10 Time 13:11 Rev Time 0.00
Received By gjohnson Date 2015-12-10 Time 13:11 Sent To  
Notes
2015-12-10 13:33:511ST REVIEW: FBC 2014
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. THE FIXTURE DRAIN FOR WASHING MACHINE MUST TIE INTO
 BUILDING DRAIN DOWNSTREAM OF THE BATHROOM GROUP. PER
 FBC P SEC 912.1
 SHEET P-1 REFERS TO PLUMBING CODE AS FBC 2901 IT SHALL
 BE FBC 2014.
 3. P-1 AND E-1 DO NOT COMPLY WITH FAC SEC 61G15-23.003
 PROCEDURES FOR PHYSICALLY SIGNING AND SEALING PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
 ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR OTHER
 DOCUMENTS WHICH MUST BE SIGNED, DATED AND SEALED IN
 ACCORDANCE WITH THE PROVISIONS OF SECTION 471.025,
 F.S., AND RULE 61G15-23.001, F.A.C. MAY BE PHYSICALLY
 SIGNED, DATED AND SEALED AS PROVIDED HEREIN BY THE
 PROFESSIONAL ENGINEER IN RESPONSIBLE CHARGE.
 (1) THE LICENSEE SHALL SIGN BY HAND AN ORIGINAL OF THE
 LICENSEE?S SIGNATURE ON EACH PAGE REQUIRED TO BE
 SEALED. A SCANNED, FACSIMILE, DIGITALLY CREATED OR
 COPIED IMAGE OF THE LICENSEE?S SIGNATURE SHALL NOT BE
 USED.
 (2) THE LICENSEE MUST THEN USE A WET SEAL, A DIGITALLY
 CREATED SEAL, OR AN EMBOSSING SEAL PLACED PARTIALLY
 OVERLAPPING THE LICENSEE?S SIGNATURE ON EACH PAGE
 REQUIRED TO BE SEALED. THE PLACEMENT OF THE SEAL SHALL
 NOT RENDER THE SIGNATURE ILLEGIBLE
 4. APPLICATION REFERENCES SWIMMING POOL BUT ITS NOT ON
 THE PRINT PLEASE CLARIFY. PER WPB AMEND. TO FBC SEC
 107.2.1
  

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2016-02-01 Cont ID  
Sent By cthroop Date 2016-02-01 Time 10:02 Rev Time 0.00
Received By cthroop Date 2016-02-01 Time 10:02 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2016-01-21 Cont ID  
Sent By cthroop Date 2016-01-21 Time 14:03 Rev Time 0.00
Received By cthroop Date 2016-01-21 Time 14:03 Sent To  
Notes
2016-01-21 14:04:49CHRISTOPHER S. THROOP, C.B.O.
 BLDG. PLANS EXAMINER ? PX3169
 (561) 805-6718
 [email protected]
  
 PROVIDE PRODUCT APPROVALS FOR PROPOSED ROOF SHINGLES.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS.
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2016-01-13 Cont ID  
Sent By cthroop Date 2016-01-13 Time 11:32 Rev Time 0.00
Received By cthroop Date 2016-01-13 Time 11:32 Sent To  
Notes
2016-01-13 11:34:36CHRISTOPHER S. THROOP, C.B.O.
 BLDG. PLANS EXAMINER ? PX3169
 (561) 805-6718
 [email protected]
  
 PROVIDE PRODUCT APPROVALS FOR ROOFING MATERIALS.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS.
  

Review Stop Z ZONING
Rev No 1 Status P Date 2016-01-11 Cont ID  
Sent By fmittner Date 2016-01-11 Time 11:16 Rev Time 0.00
Received By fmittner Date 2016-01-11 Time 11:15 Sent To  
Notes
***NONE***