Plan Review Details - Permit 15120092
Plan Review Stops For Permit 15120092
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-01-14 Cont ID  
Sent By jwitmer Date 2016-01-14 Time 12:30 Rev Time 0.00
Received By jwitmer Date 2016-01-14 Time 11:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-12-09 Cont ID  
Sent By   Date 2015-12-09 Time 06:45 Rev Time 0.00
Received By jwitmer Date 2015-12-09 Time 06:09 Sent To E
Notes
2015-12-09 06:50:57BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15120092
 ADD: 510 43RD ST.
 CONT: CBJ CONSTRUCTION
 TEL: 305-219-9791
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
  
 1ST REVIEW
 DATE: WED. DEC. 09/ 2015
 ACTION: DENIED
  
 1) SHEET A-1 CODE CRITERIA;
  
 1A) THE PLANS INDICATE THE CODE USED IN THE DESIGN OF
 THESE DOCUMENTS WAS THE 2010 FBC. PLEASE NOTE JUNE 30/
 2015 STATEWIDE THE 5TH EDITION OF THE FAMILY OF FLORIDA
 BUILDING CODE (FBC 2014) WAS ADOPTED STATEWIDE.
  
 1B) THE WIND DESIGN CRITERIA INDICATES THIS STRUCTURE
 IS IN A WIND ZONE OF 175 MPH. PLEASE NOTE THAT UNDER
 THE 2014 FBC-B CATEGORY II BUILDINGS LIE IN A 170 MPH
 VULT WIND ZONE. SEE 2014 FBC-B FIGURE 1609A.
  
 2) SHEET A-1 BUILDING TYPE & OCCUPANCY:
 2A) THE DESIGNER OF RECORD HAS LISTED THE OCCUPANCY AS
 A R3 -SINGLE FAMILY. UNDER THE BUSINESS TAX FOR THIS
 ADDRESS IT IS LISTED FOR 10 APARTMENTS MAKING ALL
 DWELLING UNITS A R2 OCCUPANCY. 2014 FBC-B 310.4
  
 2B) IT APPEARS THERE IS A DISCREPANCY IN EITHER THE
 SCOPE OF WORK OR IN THE LEVEL OF ALTERATION THAT IS
 TAKING PLACE UNDER THIS PERMIT. SCOPE OF WORK LISTED IN
 THE PLANS MAKES IT SOUND AS THIS IS A LEVEL 1
 ALTERATION :
  
 2014 EXST. BLDG. CODE 503.1 SCOPE. LEVEL 1 ALTERATIONS
 INCLUDE THE REMOVAL AND REPLACEMENT OR THE COVERING OF
 EXISTING MATERIALS, ELEMENTS, EQUIPMENT, OR FIXTURES
 USING NEW MATERIALS, ELEMENTS, EQUIPMENT, OR FIXTURES
 THAT SERVE THE SAME PURPOSE.
  
 WHERE AS THE PLANS INDICATE A LEVEL II ALTERATION :
 504.1 SCOPE. LEVEL 2 ALTERATIONS INCLUDE THE
 RECONFIGURATION OF SPACE, THE ADDITION OR ELIMINATION
 OF ANY DOOR OR WINDOW, THE RECONFIGURATION OR EXTENSION
 OF ANY SYSTEM, OR THE INSTALLATION OF ANY ADDITIONAL
 EQUIPMENT.
  
 WHAT PART OF THE TENANT SPACE IS BEING RECONFIGURED OR
 WHAT SYSTEM IS BEING ECONFIGURATION OR EXTENSION OF ANY
 SYSTEM, OR THE INSTALLATION OF ANY ADDITIONAL
 EQUIPMENT?
  
 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2016-01-20 Cont ID  
Sent By mvaldes Date 2016-01-20 Time 15:54 Rev Time 0.00
Received By mvaldes Date 2016-01-20 Time 15:54 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-01-06 Cont ID  
Sent By mvaldes Date 2016-01-06 Time 10:08 Rev Time 0.00
Received By mvaldes Date 2016-01-06 Time 10:08 Sent To  
Notes
2016-01-06 10:10:34 
 1ST REVIEW: FBC 2014 5TH ED. NEC 2011/RESIDENTIAL
 MARIO VALDES
 ELECTRICAL PLAN EXAMINER
 516-805-6700
 [email protected]
 ALTERNATE CONTACT
 MIKE ALBARRAN
 561-805-6746
 [email protected]
  
  
  
 .2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 ELECTRONIC MEDIA 107DOCUMENTS SHALL BE
 SUBMITTED WHEN APPROVED BY THE BUILDING OFFICIAL.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES
 SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE
 TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE
 FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE
 DESIGN. (SEE ALSO SECTION 107.3.5).
  
 DFINE SCOPE OF WORK AND SHOW ALL OUTLETS IN PLANS.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2016-01-25 Cont ID  
Sent By pleduc Date 2016-01-25 Time   Rev Time 0.00
Received By pleduc Date 2016-01-25 Time 16:11 Sent To PC
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-12-03 Cont ID  
Sent By J.Walker Date 2015-12-03 Time   Rev Time 0.10
Received By   Date 2015-12-03 Time   Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-01-25 Cont ID  
Sent By pleduc Date 2016-01-25 Time   Rev Time 0.00
Received By pleduc Date 2016-01-21 Time 08:48 Sent To  
Notes
2016-01-21 08:48:17ROUTED TO FIRE - THEY NEED TO PUT THEIR STAMP ON THE
 NEW PLANS WAS MISSED IN INITIAL INCOMING

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-01-21 Cont ID  
Sent By lmarchan Date 2016-01-21 Time 08:05 Rev Time 0.00
Received By lmarchan Date 2016-01-08 Time 16:12 Sent To  
Notes
2016-01-08 16:12:43B21

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-01-06 Cont ID  
Sent By cpuell Date 2016-01-06 Time 14:17 Rev Time 0.00
Received By cpuell Date 2015-12-02 Time 11:01 Sent To  
Notes
2015-12-02 11:16:28B13

Review Stop P PLUMBING
Rev No 2 Status P Date 2016-01-16 Cont ID  
Sent By gjohnson Date 2016-01-16 Time 09:22 Rev Time 0.00
Received By gjohnson Date 2016-01-16 Time 09:22 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-12-06 Cont ID  
Sent By tklarge Date 2015-12-06 Time 06:51 Rev Time 0.00
Received By tklarge Date 2015-12-06 Time 06:43 Sent To  
Notes
2015-12-06 06:47:341) CLEARLY DESCRIBE ON THE PLANS THE TYPE OF "REPAIR"
 THAT IS BEING DONE TO THE SANITARY AND WATER LINES.
 THIS IS A VAGUE DESCRIPTION. WPB AMEND. TO FBC SEC.
 107.2.1.
 2) CLEARLY INDICATE ON THE PLANS IF ANY OF THE PLUMBING
 FIXTURES ARE BEING REPLACED. WPB AMEND. TO FBC SEC.
 107.2.1.
  
 PLUMBING PLAN REVIEW
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 561-805-6692
 [email protected]
  