Plan Review Details - Permit 15111037
Plan Review Stops For Permit 15111037
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-03-14 Cont ID  
Sent By jwitmer Date 2016-03-14 Time 09:20 Rev Time 0.00
Received By jwitmer Date 2016-03-14 Time 09:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-12-09 Cont ID  
Sent By jwitmer Date 2015-12-09 Time 08:53 Rev Time  
Received By jwitmer Date 2015-12-09 Time 07:45 Sent To  
Notes
2015-12-09 08:53:09BUILDING PLAN REVIEW
 W. P. B. PERMIT: 15111037
 ADD: 120 S. OLIVE AVE. SUITE?
 CONT: TBD
 TEL: 561-659-2383
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
  
 1ST REVIEW
 DATE: WED. DEC. 09/2015
 ACTION: DENIED
  
 1) ADDITIONAL INFORMATION IS REQUIRED. 107.2.1.3. THE
 PERMIT APPLICATION LIST THE ADDRESS OF 120 S. OLIVE
 AVE. NO SUITE NUMBER IS GIVEN. THE PLANS SHEET A-0.00
 INDICATE THIS IS A NEW SUITE # 600. IS THIS A
 SUB-DIVISION OF THE EXISTING SUITE 600? SHEET A-0.00
 INDICATES (2) NEW SUITES, 600, 601, AND 602. PLEASE
 NOTE IF SO A NEW TENANT SUITE NUMBER WILL BE REQUIRED.
 THE OTHER ISSUE IS IF THE SUITE 600 WAS SUB-DIVIDED
 THEN IT WILL NEED TO BE RECORDED SINCE THIS IS A
 COMMERCIAL CONDOMINIUM, DECLARATION OF CONDOMINIUM.
  
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK
 PROPOSED.
 2014 FBC-B 501.2 ADDRESS IDENTIFICATION.
  
 2) SHEET A-0.00 SOMEONE HAS X-ED OUT THE WORK SHOWN ON
 THE PLAN FOR THE 2ND FLOOR. THIS IS NOT BEEN INITIALED
 BY THE DESIGNER OF RECORD AND DATED.
 IN THE CODE ANALYSIS THE WRITTEN DESCRIPTION OF WORK
 STILL SHOWS WORK TO BE PREFORMED ON THE 2ND FLOOR.
 107.2.1.3 DISCREPANCY IN PLANS, PLEASE PROVIDE
 ADDITIONAL INFORMATION. ONLY THE DESIGNER OF RECORD CAN
 MODIFY THE PLANS BY APPLYING THERE INITIALS AND DATING
 THE RED LINED DRAWING. FL ADMIN CODE 61G16.003
 ARCHITECTS.
  
 3) SHEET A-0.00 SUITE # 602 THE EAST ENTRY DOOR IT
 APPEARS THERE IS ONLY 12 INCHES ON THE LATCH SIDE OF
 THE INSWING DOOR. THE 2014 FBC-ACCESSIBILITY CODE
 SECTION 404.2.4 MANEUVERING CLEARANCES REQUIRES A
 MINIMUM OF 18 INCHES. ALSO SEE FIGURE 404.2.4.1(A).
  
 4) NONE OF THE ARCHITECTURALS SHEETS PROVIDES
 IDENTIFICATION OF DOORS NOR IS THERE A DOOR SCHEDULE TO
 BE ABLE TO VERIFY CODE COMPLIANCE WITH:
 2014 FBC-B 1008.1.1 MINIMUM EGRESS DOOR SIZE.
 2014 FBC-ACCESSIBILITY 404.2.3 CLEAR WIDTH.
  
 5) SHEET A-0.00 THE ROOM JUST TO THE RIGHT AND ADJACENT
 TO THE EAST STAIR DOES NOT CLEARLY STATE IF DEPICTED IS
 A FLOOR SINK, WORK ROOM SINK OR A BREAK ROOM SINK IS IN
 THE NORTH EAST CORNER OF THE ROOM. IT IS NOT CLEAR IF
 COMPLIANCE WITH THE 2014 FBC-ACCESSIBILITY CODE 606.
 1-5 IS REQUIRED?
  
 6) THERE ARE NO FIRE SPRINKLER PLANS SUBMITTED SHOWING
 THE LOCATION OF THE EXISITNG SPRINKLER HEADS, IF HEADS
 NEED TO BE MOVED? THERE WERE DEMOLTION PLANS SUBMITTED
 SHOWING WHAT WALLS ARE OLD AND WHICH WALLS ARE MOVED
 AND OR NEW WALLS. 2014 FLORIDA BUILDING CODE W 2014
 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION 107.3.5.1.1 MINIMUM
 PLAN REVIEW CRITERIA FOR COMMERCIAL BUILDINGS.(5)
 SCHEMATIC FIRE SPRINKLERS.
  
 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2016-01-20 Cont ID  
Sent By albarran Date 2016-01-20 Time 17:52 Rev Time 0.00
Received By albarran Date 2016-01-20 Time 16:31 Sent To  
Notes
2016-01-20 17:53:17NOTICE TO ELECTRICAL CONTRACTOR
 ALL ELECTRICAL BOXES IN A DEMISING WALL SHALL COMPLY
 WITH NEC 300.21 & FBC-B SECTION 714. ANY FIRE-RATED
 STRUCTURE OR SURFACE THAT IS COMPROMISED SHALL BE
 RETURNED TO ITS ORIGINAL FIRE-RATING WITH APPROVED FIRE
 SEALING MATERIAL.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status N Date 2016-01-12 Cont ID  
Sent By   Date 2016-01-12 Time   Rev Time 0.00
Received By   Date 2016-01-12 Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-12-03 Cont ID  
Sent By pleduc Date 2015-12-03 Time   Rev Time 0.00
Received By pleduc Date 2015-12-03 Time 15:03 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status N Date 2015-12-16 Cont ID  
Sent By aaponte Date 2015-12-16 Time 14:25 Rev Time 0.00
Received By aaponte Date   Time   Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-03-18 Cont ID  
Sent By ccole Date 2016-03-18 Time 17:08 Rev Time 0.00
Received By ccole Date 2016-03-08 Time 13:18 Sent To  
Notes
2016-03-08 13:18:48B14

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-01-21 Cont ID  
Sent By ccole Date 2016-01-21 Time 06:54 Rev Time 0.00
Received By ccole Date 2015-11-25 Time 15:56 Sent To  
Notes
2015-12-01 15:57:20B14

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2016-03-18 Cont ID  
Sent By ccole Date 2016-03-18 Time 17:08 Rev Time 0.00
Received By ccole Date 2016-03-18 Time 16:50 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2016-01-21 Cont ID  
Sent By ccole Date 2015-12-08 Time 06:54 Rev Time 0.00
Received By ccole Date 2015-12-08 Time 08:07 Sent To  
Notes
2015-12-08 08:23:041ST REVIEW 2014 MECHANICAL
 PERMIT #15111037
 12/8/15
  
 1) SHEET M5.1: OUTDOOR AIR CALCULATIONS FOR THE AC
 SYSTEMS OPERATING ON THE 2ND FLOOR ARE IN THE SCHEDULE,
 HOWEVER NO AC PLANS FOR THE 2ND FLOOR ARE INCLUDED IN
 THE PLAN SETS: PLEASE PROVIDE THE PLANS.
 2) M1.2 AND M5.1: PLEASE LABEL THE OFFICE ROOMS ON THE
 AC PLANS TO MATCH THE LABELING IN THE O/A SCHEDULE.
 3) M1.2 AND M5.1: THE O/A SCHEDULE INDICATES AIR BEING
 PROVIDED TO CORRIDOR 5 IN SUITE 601, HOWEVER THERE ARE
 NO AC DROPS SHOWN IN THE LAYOUT PLANS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 2 Status N Date 2016-03-17 Cont ID  
Sent By gjohnson Date 2016-03-17 Time 11:42 Rev Time 0.00
Received By gjohnson Date 2016-03-17 Time 11:42 Sent To  
Notes
2016-03-17 11:43:40 
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 ALL PLUMBING SHOWN AS EXISTING.

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-12-06 Cont ID  
Sent By gjohnson Date 2015-12-06 Time 13:08 Rev Time 0.00
Received By gjohnson Date 2015-12-06 Time 13:08 Sent To  
Notes
2015-12-06 13:12:101ST REVIEW: FBC 2014
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
 1. PLEASE CLARIFY IT DOES NOT APPEAR TO HAVE ANY WORK
 BEING DONE ON PLUMBING SYSTEM.

Review Stop Z ZONING
Rev No 1 Status N Date 2015-12-16 Cont ID  
Sent By aaponte Date 2015-12-16 Time 14:24 Rev Time 0.00
Received By aaponte Date 2015-12-16 Time 14:24 Sent To  
Notes
***NONE***