Plan Review Details - Permit 15111031
Plan Review Stops For Permit 15111031
Review Stop AD ADDRESSING
Rev No 4 Status P Date 2016-03-10 Cont ID  
Sent By shill Date 2016-03-10 Time 13:16 Rev Time 0.00
Received By shill Date 2016-03-10 Time 13:15 Sent To  
Notes
2016-03-10 13:16:20PROVISO - APPLICANT HAS AGREED TO OBTAIN BTR
  
  

Review Stop AD ADDRESSING
Rev No 3 Status F Date 2016-03-10 Cont ID  
Sent By shill Date 2016-03-10 Time 12:14 Rev Time 0.00
Received By shill Date 2016-03-10 Time 12:14 Sent To  
Notes
2016-03-10 12:18:51****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. SUBMIT A BUSINESS TAX APPLICATION FOR THE
 RESIDENTIAL RENTAL. PLEASE NOTIFY WHEN THIS HAS BEEN
 SUBMITTED.
  
  
  

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2016-02-29 Cont ID  
Sent By shill Date 2016-02-29 Time 12:29 Rev Time 0.00
Received By shill Date 2016-02-29 Time 12:29 Sent To  
Notes
2016-02-29 12:29:40****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. I WAS UNABLE TO FIND ANY BUSINESS TAX RECEIPTS FOR
 THE SECOND FLOOR. HOW MANY APARTMENT UNITS ARE ON THE
 SECOND FLOOR? PLEASE PROVIDE INFORMATION REGARDING THIS
 AREA.
  
 PROVIDE INFORMATION REGARDING THE SECOND FLOOR AND ALL
 ADDRESSES CURRENTLY USED FOR THIS BUILDING.
  
  

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2016-01-07 Cont ID  
Sent By shill Date 2016-01-07 Time 10:46 Rev Time 0.00
Received By shill Date 2016-01-07 Time 09:31 Sent To  
Notes
2016-01-07 16:51:27****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. I WAS UNABLE TO FIND ANY BUSINESS TAX RECEIPTS FOR
 THE SECOND FLOOR. HOW MANY APARTMENT UNITS ARE ON THE
 SECOND FLOOR? PLEASE PROVIDE INFORMATION REGARDING THIS
 AREA.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2016-03-10 Cont ID  
Sent By shill Date 2016-03-10 Time 12:14 Rev Time 0.00
Received By shill Date 2016-03-10 Time 11:03 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2016-02-29 Cont ID  
Sent By shill Date 2016-02-29 Time 14:46 Rev Time 0.00
Received By shill Date 2016-02-26 Time 18:59 Sent To  
Notes
2016-02-29 14:52:44****PROVISO****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 PRODUCT APPROVALS REVIEWED BY DESIGNER OF RECORD ARE
 REQUIRED FOR THE MECH STAND, STOREFRONT, AND DOORS.
 THEY ARE TO BE SUBMITTED, REVIEWED AND APPROVED PRIOR
 TO INSTALLATION.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2015-12-05 Cont ID  
Sent By shill Date 2015-12-05 Time 14:53 Rev Time 0.00
Received By shill Date 2015-12-05 Time 14:53 Sent To  
Notes
2015-12-05 14:57:34****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. A5, AREA PER OCCUPANT CANNOT BE LESS THAN THE TABLE,
 FBC 5TH ED. TABLE 1004. 100 SF PER OCCUPANT SHOWN;
 MERCANTILE REQUIRES 30 SF PER OCCUPANT MAX; REVISE.
  
 2. A2, THIS IS A CHANGE OF OCCUPANCY FROM ASSEMBLY TO
 MERCANTILE. INCORPORATE THIS INTO THE PLAN AND SHOW
 COMPLIANCE WITH REQUIREMENTS OF FBC 5TH EDITION
 EXISTING BUILDING CHAPTER 10.
  
 3. ADVISORY ONLY: PRODUCT APPROVALS REVIEWED BY
 DESIGNER OF RECORD ARE REQUIRED FOR THE MECH STAND,
 STOREFRONT, AND DOORS. THEY ARE TO BE SUBMITTED,
 REVIEWED AND APPROVED PRIOR TO INSTALLATION.
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2016-03-09 Cont ID  
Sent By albarran Date 2016-03-09 Time 14:48 Rev Time 0.00
Received By albarran Date 2016-03-09 Time 14:35 Sent To P
Notes
2016-03-09 14:50:073/9/16 ALL PREVIOUSLY MENTIONED DEFICIENCIES HAVE BEEN
 SATISFACTORILY ADDRESSED. WALKED FILE OVER TO GJOHNSON
 FOR PLUMBING REVIEW.,

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2016-02-23 Cont ID  
Sent By albarran Date 2016-02-23 Time 14:58 Rev Time 0.00
Received By albarran Date 2016-02-23 Time 12:35 Sent To  
Notes
2016-02-23 14:59:152ND ELECTRICAL REVIEW NOTES FOR PERMIT #:15111031
 REVIEWED FOR COMPLIANCE WITH:
 FBC 5TH EDITION 2014
 NFPA 70 2011 (NEC)
  
 CORRECTIONS REQUIRED:
 1. SHEET CS1 SECTION 4 PROJECT DESCRIPTION REFERS TO
 THE 2008 EDITION OF THE NEC. THE APPLICABLE NEC CODE IN
 EFFECT IS THE 2011 EDITION. CORRECT THE NOTE
 ACCORDINGLY.
 2. AS PREVIOUSLY MENTIONED, NEC 300.21 AS WELL AS THE
 FBC HAVE SPECIFIC REQUIREMENTS FOR FIRE STOPPING.
 SUBMIT A FIRE STOPPING DETAIL FOR ELECTRICAL BOXES
 INSTALLED IN A DEMISING OR FIRE RATED WALL.
 3. YOU HAVE NOT PROVIDED A LIGHTING DIAGRAM AS REQUIRED
 BY FBC-EC405. THIS REQUIRES THAT YOU SUBMIT A FIXTURE
 SCHEDULE, LIGHT DENSITY ALLOWANCE CHART ALONG WITH THE
 REQUIRED LIGHTING CONTROLS. IN ADDITION TO THIS SHOW
 THE LIGHTING CIRCUITS ON THE FLOOR PLAN BECAUSE AS
 INDICATED IN NEC 700.12 THE EMERGENCY LIGHTING SHALL BE
 TIED IN TO THE LIGHTING CIRCUIT OF THE AREA THEY
 OCCUPY.
 4. THE STAIRWAYS CONTINUE TO BE MISSING THE REQUIRED
 EMERGENCY LIGHTING.
 5. YOU SHALL SUBMIT MANUFACTURER SPEC SHEET FOR THE
 TWH.
 6. THE RISER DIAGRAM FAILS TO SHOW THE REQUIRED
 INTER-SYSTEM BONDING TERMINAL INDICATED IN NEC 250.94.
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER
 (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER
 WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD
 CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID
 AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR
 COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE
 GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 THANK YOU,
 MIKE ALBARRAN
 ELECTRICAL PLANS EXAMINER
 PH: 561-805-6746
 EMAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2016-01-06 Cont ID  
Sent By albarran Date 2016-01-06 Time 19:21 Rev Time 0.00
Received By albarran Date 2016-01-06 Time 17:39 Sent To  
Notes
2016-01-06 19:22:05THE PLANS FOR THE ABOVE MENTIONED REVISION HAS BEEN
 REVIEWED FOR COMPLIANCE WITH THE EDITION OF THE NEC,
 (NATIONAL ELECTRICAL CODE), FIRE CODES AND THE FBC,
 (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST
 PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF
 SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED.
  
 1. NEC 300.21 SPREAD OF FIRE OR PRODUCTS OF COMBUSTION.
 OPENINGS AROUND ELECTRICAL PENETRATIONS INTO OR THROUGH
 FIRE-RESISTANT-RATED WALL, PARTITIONS, FLOORS OR
 CEILINGS SHALL BE FIRE-STOPPED USING APPROVED METHODS
 TO MAINTAIN THE FIRE RESISTANCE RATING. SEE FBC-B
 SECTION 714.
 2. NEC 406.9(B) RECEPTACLES IN WET LOCATIONS. 15 AND 20
 AMPERE, 125 AND 250 VOLT RECEPTACLES INSTALLED IN A WET
 LOCATION SHALL HAVE AN ENCLOSURE THAT IS WEATHERPROOF
 WHETHER OR NOT THE ATTACHMENT PLUG CAP IS INSERTED. ALL
 15 AND 20 AMPERE, 125 AND 250 VOLT NONLOCKING
 RECEPTACLES SHALL BE LISTED WEATHER-RESISTANT TYPE
 ?WR?.
 3. NEC 700.12 (F) (4) - EMERGENCY LIGHTING SHALL BE FED
 BY LIGHTING CIRCUIT OF SAME LOCAL AREA. *IF 3 OR MORE
 LIGHTING CIRCUITS SUPPLY THE AREA, EM LIGHTS MAY BE ON
 OWN CIRCUIT.
 4. STAIRS SHALL BE PROVIDED WITH EMERGENCY
 ILLUMINATION.
 5. FBC-E C402.4.8 RECESSED LIGHTING. RECESSED LIGHTING
 INSTALLED IN THE BUILDING THERMAL ENVELOPE SHALL BE IC
 RATED AND BE SEALED TO LIMIT AIR LEAKAGE BETWEEN
 CONDITIONED & UNCONDITIONED SPACES.
 6. NEC 300.50 UNDERGROUND INSTALLATIONS. (F) WHERE A
 RACEWAY ENTERS FROM AN UNDERGROUND SYSTEM, THE ENDS
 SHALL BE SEALED WITH A LISTED COMPOUND TO PREVENT THE
 ENTRANCE OF MOISTURE OR GASES CONTACTING LIVE PARTS.
  
 WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR
 RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE
 LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE
 STANDARD CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE
 INSERT CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK
 VOID AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR
 COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE
 GREATLY APPRECIATED.
  
 IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO
 CONTACT ME DIRECTLY.
  
 THANK YOU,
 MIKE ALBARRAN
 ELECTRICAL PLANS EXAMINER
 PH: 561-805-6746
 EMAIL: [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2016-03-07 Cont ID  
Sent By pleduc Date 2016-03-07 Time   Rev Time 0.00
Received By pleduc Date 2016-03-04 Time 16:51 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2016-02-11 Cont ID  
Sent By pleduc Date 2016-02-11 Time   Rev Time 0.00
Received By pleduc Date 2016-02-10 Time 16:38 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2015-12-04 Cont ID  
Sent By pleduc Date 2015-12-04 Time   Rev Time 0.00
Received By pleduc Date 2015-12-04 Time 10:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2016-03-10 Cont ID  
Sent By shill Date 2016-03-10 Time 13:16 Rev Time 0.00
Received By shill Date 2016-03-03 Time 14:19 Sent To  
Notes
2016-03-03 14:19:42B28

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2016-02-29 Cont ID  
Sent By shill Date 2016-02-29 Time 12:29 Rev Time 0.00
Received By shill Date 2016-02-08 Time 15:00 Sent To  
Notes
2016-02-08 15:00:30B27

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2016-01-07 Cont ID  
Sent By shill Date 2016-01-07 Time 16:52 Rev Time 0.00
Received By shill Date 2015-11-25 Time 13:19 Sent To  
Notes
2015-11-25 13:19:49B05

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2016-01-07 Cont ID  
Sent By shill Date 2016-01-07 Time 16:51 Rev Time 0.00
Received By shill Date 2016-01-07 Time 09:31 Sent To  
Notes
2016-01-07 16:52:36GREEN CARD SHOWS FOUR RETAIL UNITS FIRST FLOOR; IMPACT
 FEE ASSESSMENT NOT REQUIRED PER MICHELLE BONANNI
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2016-03-10 Cont ID  
Sent By ccole Date 2016-03-10 Time 07:48 Rev Time 0.00
Received By ccole Date 2016-03-10 Time 07:48 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2016-02-16 Cont ID  
Sent By ccole Date 2016-02-16 Time 10:22 Rev Time 0.00
Received By ccole Date 2016-02-16 Time 10:22 Sent To  
Notes
2016-02-16 10:49:422ND REVIEW: FBC 2014 MECHANICAL
 PERMIT #15111031
 2/16/16
  
 1) THE SUBMITTED AC CALCULATIONS ARE BASED ON DESIGN
 TEMPERATURES FROM MIAMI FL. PLEASE REVISE THE
 CALCULATIONS USING DESIGN TEMPERATURES FROM WEST PALM
 BEACH- REFER TO ACCA MANUAL N- SEE SECTION C403.2.1
 FBC-14 ENERGY CONSERVATION
 2) PLEASE INDICATE THE DIRECTIONAL ORIENTATIONS OF THE
 TENANT SPACES ON THE AC CALCULATIONS- SECTION C403.2.1.
 3) PLEASE PROVIDE AC EQUIPMENT SCHEDULES ON THE PLAN-
 THE IS NO WAY TO VERIFY THE COMPLIANCE DATA FOR THE
 SYSTEMS LISTED IN THE SUBMITTED ASHRAE 90.1 ENERGY COST
 BUDGET OPTION FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2015-12-01 Cont ID  
Sent By ccole Date 2015-12-01 Time 15:33 Rev Time  
Received By ccole Date   Time   Sent To  
Notes
2015-12-01 16:44:101ST REVIEW 2014 MECHANICAL
 PERMIT #15111031
 12/1/15
  
 1) PROVIDE AC COOLING AND HEATING LOAD CALCULATIONS IN
 ACCORDANCE WITH ASHRAE/ACCA STANDARD 183 OR ACCA MANUAL
 N- SEE SECTION C303.2.1 FBC-14 ENERGY CALCULATIONS.
 2) THE PLANS INDICATES A CHANGE IN OCCUPANCY
 CLASSIFICATION FROM THE PREVIOUS ASSEMBLY OCCUPANCY TO
 FOUR NEW MERCANTILE OCCUPANCIES- COMPLIANCE WITH THE
 FBC-14 ENERGY CONSERVATION CODE IS REQUIRED. PLEASE SEE
 SECTION C101.4.4 AND SUBMIT EITHER THE PRESCRIPTIVE
 COMPLIANCE FORM R402, OR THE ENERGY GAUGE PERFORMANCE
 BASED FORM 506-2014.
 3) SHEET A-8: THE DOOR SCHEDULE INDICATES WOOD LOUVERED
 DOORS FOR THE NEW AIR HANDLER CLOSETS- REFER TO SECTION
 602 FBC-14 MECHANICAL, AND C403.2.7.2 FBC-14 ENERGY
 CONSERVATION AND PROVIDE NON-COMBUSTIBLE DOORS.
 4) M-1: PROVIDE TOILET ROOM EXHAUST DUCT DETAILS OR
 NOTES FOR RETAIL SPACES #2 & #3.
 5) M-2: PROVIDE THE WIND LOAD DESIGN CRITERIA FOR TIE
 DOWN OF THE CONDENSERS TO THE EXISTING STANDS- SEE
 SECTION 301.15 FBC-14 MECHANICAL.
 6) M-2: THE MINIMUM 18" SPACING BETWEEN THE CONDENSERS
 ON THE ROOF STANDS MUST BE VERIFIED TO BE IN ACCORDANCE
 WITH THE MANUFACTURER'S RECOMMENDATIONS- PLEASE SUBMIT
 DOCUMENTATION.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2016-03-09 Cont ID  
Sent By gjohnson Date 2016-03-09 Time 15:26 Rev Time 0.00
Received By gjohnson Date 2016-03-09 Time 15:25 Sent To  
Notes
2016-03-09 15:27:32PLUMBING PROVISO
 PLAN APPROVED WITH EXCEPTION !! FAILURE TO CORRECT
 LISTED DEFICIENCIES PRIOR TO INSPECTION WILL RESULT IN
 FAILED INSPECTIONS AND REINSPECTION FEES
 1. HOT WATER REQUIRED AT SERVICE SINK. PER FBC PL. SEC
 607.1
  
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  
  
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2016-02-19 Cont ID  
Sent By gjohnson Date 2016-02-19 Time 16:35 Rev Time 0.00
Received By gjohnson Date 2016-02-19 Time 16:35 Sent To  
Notes
2016-02-19 16:56:132ND REVIEW: FBC 2014
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. UNDER THIS PERMIT EACH UNIT IS REQUIRED TO COMPLY
 WITH FBC PL SEC 403.1 TABLE 403.1
  
 (A) WATER FOUNTAINS ARE REQUIRED AND SHALL COMPLY WITH
 FBC ACC SEC. 602+307 AND FBC PL SEC. 410.2
  
 (B) A SERVICE SINK.
  
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2015-12-06 Cont ID  
Sent By gjohnson Date 2015-12-06 Time 11:56 Rev Time 0.00
Received By gjohnson Date 2015-12-06 Time 11:45 Sent To  
Notes
2015-12-06 11:56:251ST REVIEW: FBC 2014
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1.WATER FOUNTAINS ARE REQUIRED PER FBC PL SEC 404.1 AND
 TABLE 403.1. SHALL COMPLY WITH FBC ACC. SEC 602
 2.THE WATER CLOSET SHALL BE POSITIONED WITH A WALL OR
 PARTITION TO THE REAR AND TO ONE SIDE. THE CENTERLINE
 OF THE WATER CLOSET SHALL BE 16 INCHES (405 MM) MINIMUM
 TO 18 INCHES (455 MM) MAXIMUM FROM THE SIDE WALL OR
 PARTITION. PER FBC ACC SEC 604.2
 3. GRAB BARS SHALL BE MEASURED TO THE TOP OF THE
 GRIPPING SURFACE TO FINISHED FLOOR. PER FBC ACC. SEC
 609.4
 4.HOT WATER OR TEMPERED WATER SHALL BE SUPPLIED FOR
 BATHING AND WASHING PURPOSES INCLUDING HAND WASHING
 .PER FBC PL SEC.607.1

Review Stop Z ZONING
Rev No 3 Status P Date 2016-03-10 Cont ID  
Sent By dkittred Date 2016-03-10 Time 08:53 Rev Time 0.00
Received By dkittred Date 2016-03-10 Time 08:53 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2016-02-18 Cont ID  
Sent By dkittred Date 2016-02-18 Time 18:03 Rev Time 0.00
Received By dkittred Date 2016-02-18 Time 08:38 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2015-12-07 Cont ID  
Sent By dkittred Date 2015-12-07 Time 16:48 Rev Time 0.00
Received By dkittred Date 2015-12-07 Time 10:38 Sent To  
Notes
2015-12-07 16:46:43PLANNING AND ZONING COMMENTS: ***FAILED***
  
 12/7/15
  
 1. PROVIDE EVIDENCE THAT THE PROPOSED AC UNITS ON THE
 ROOF WILL NOT BE VISIBLE FROM THE STREET. IF THE UNITS
 WILL BE HIGHER THAN THE PARAPET, SCREENING WILL NEED TO
 BE PROVIDED AROUND THE UNITS AND MUST BE SHOWN ON THE
 PLAN.
  
 GENERAL COMMENTS:
  
 A. PROPOSED AWNINGS WILL REQUIRED A SEPARATE PERMIT,
 PLAN REVIEW, AND FEE. PLEASE BE ADVISED THAT AT TIME OF
 SUBMITTAL FOR THE AWNINGS, A PROPERTY SURVEY MUST BE
 SUBMITTED TO DEMONSTRATE WHETHER OR NOT THE AWNINGS
 ENCROACH OVER THE PUBLIC RIGHT-OF-WAY. ANY ENCROACHMENT
 OF THE AWNINGS OVER THE PUBLIC RIGHT-OF-WAY ALONG DIXIE
 HIGHWAY WILL REQUIRE APPROVAL BY FDOT AS DIXIE HIGHWAY
 IS A STATE ROAD.
  
 B. PLEASE BE ADVISED THAT WHEN RENOVATION COSTS EXCEED
 50% THE VALUE OF THE STRUCTURE, A LANDSCAPE PLAN IN
 ACCORDANCE WITH ZLDR ARTICLE XIV WILL BE REQUIRED TO BE
 SUBMITTED TO BRING THE SITE INTO COMPLIANCE WITH
 LANDSCAPING REQUIREMENTS. AS OF THIS PERMIT, THE
 PROPOSED CONSTRUCTION COST IS $186,000 WHICH IS JUST
 UNDER 50% THE VALUE OF THE STRUCTURE ( $376,860)
 ACCORDING TO THE PALM BEACH COUNTY PROPERTY APPRAISER
 RECORDS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT:
  
 DANIELLE J. KITTREDGE, AICP
 SENIOR PLANNER
 PLANNING & ZONING DIVISION
 PHONE: (561)-822-1443
 EMAIL: [email protected]
  