| Plan Review Stops For Permit 15111031 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
4 |
Status |
P |
Date |
2016-03-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-03-10 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-03-10 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2016-03-10 13:16:20 | PROVISO - APPLICANT HAS AGREED TO OBTAIN BTR | | | | | | |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
F |
Date |
2016-03-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-03-10 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-03-10 |
Time |
12:14 |
Sent To |
|
|
| Notes |
| 2016-03-10 12:18:51 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. SUBMIT A BUSINESS TAX APPLICATION FOR THE | | | RESIDENTIAL RENTAL. PLEASE NOTIFY WHEN THIS HAS BEEN | | | SUBMITTED. | | | | | | | | | |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2016-02-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-02-29 |
Time |
12:29 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-02-29 |
Time |
12:29 |
Sent To |
|
|
| Notes |
| 2016-02-29 12:29:40 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. I WAS UNABLE TO FIND ANY BUSINESS TAX RECEIPTS FOR | | | THE SECOND FLOOR. HOW MANY APARTMENT UNITS ARE ON THE | | | SECOND FLOOR? PLEASE PROVIDE INFORMATION REGARDING THIS | | | AREA. | | | | | | PROVIDE INFORMATION REGARDING THE SECOND FLOOR AND ALL | | | ADDRESSES CURRENTLY USED FOR THIS BUILDING. | | | | | | |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2016-01-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-01-07 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-01-07 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2016-01-07 16:51:27 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. I WAS UNABLE TO FIND ANY BUSINESS TAX RECEIPTS FOR | | | THE SECOND FLOOR. HOW MANY APARTMENT UNITS ARE ON THE | | | SECOND FLOOR? PLEASE PROVIDE INFORMATION REGARDING THIS | | | AREA. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2016-03-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-03-10 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-03-10 |
Time |
11:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2016-02-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-02-29 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-02-26 |
Time |
18:59 |
Sent To |
|
|
| Notes |
| 2016-02-29 14:52:44 | ****PROVISO**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | PRODUCT APPROVALS REVIEWED BY DESIGNER OF RECORD ARE | | | REQUIRED FOR THE MECH STAND, STOREFRONT, AND DOORS. | | | THEY ARE TO BE SUBMITTED, REVIEWED AND APPROVED PRIOR | | | TO INSTALLATION. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2015-12-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2015-12-05 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-12-05 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2015-12-05 14:57:34 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. A5, AREA PER OCCUPANT CANNOT BE LESS THAN THE TABLE, | | | FBC 5TH ED. TABLE 1004. 100 SF PER OCCUPANT SHOWN; | | | MERCANTILE REQUIRES 30 SF PER OCCUPANT MAX; REVISE. | | | | | | 2. A2, THIS IS A CHANGE OF OCCUPANCY FROM ASSEMBLY TO | | | MERCANTILE. INCORPORATE THIS INTO THE PLAN AND SHOW | | | COMPLIANCE WITH REQUIREMENTS OF FBC 5TH EDITION | | | EXISTING BUILDING CHAPTER 10. | | | | | | 3. ADVISORY ONLY: PRODUCT APPROVALS REVIEWED BY | | | DESIGNER OF RECORD ARE REQUIRED FOR THE MECH STAND, | | | STOREFRONT, AND DOORS. THEY ARE TO BE SUBMITTED, | | | REVIEWED AND APPROVED PRIOR TO INSTALLATION. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2016-03-09 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-03-09 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-03-09 |
Time |
14:35 |
Sent To |
P |
|
| Notes |
| 2016-03-09 14:50:07 | 3/9/16 ALL PREVIOUSLY MENTIONED DEFICIENCIES HAVE BEEN | | | SATISFACTORILY ADDRESSED. WALKED FILE OVER TO GJOHNSON | | | FOR PLUMBING REVIEW., |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2016-02-23 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-02-23 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-02-23 |
Time |
12:35 |
Sent To |
|
|
| Notes |
| 2016-02-23 14:59:15 | 2ND ELECTRICAL REVIEW NOTES FOR PERMIT #:15111031 | | | REVIEWED FOR COMPLIANCE WITH: | | | FBC 5TH EDITION 2014 | | | NFPA 70 2011 (NEC) | | | | | | CORRECTIONS REQUIRED: | | | 1. SHEET CS1 SECTION 4 PROJECT DESCRIPTION REFERS TO | | | THE 2008 EDITION OF THE NEC. THE APPLICABLE NEC CODE IN | | | EFFECT IS THE 2011 EDITION. CORRECT THE NOTE | | | ACCORDINGLY. | | | 2. AS PREVIOUSLY MENTIONED, NEC 300.21 AS WELL AS THE | | | FBC HAVE SPECIFIC REQUIREMENTS FOR FIRE STOPPING. | | | SUBMIT A FIRE STOPPING DETAIL FOR ELECTRICAL BOXES | | | INSTALLED IN A DEMISING OR FIRE RATED WALL. | | | 3. YOU HAVE NOT PROVIDED A LIGHTING DIAGRAM AS REQUIRED | | | BY FBC-EC405. THIS REQUIRES THAT YOU SUBMIT A FIXTURE | | | SCHEDULE, LIGHT DENSITY ALLOWANCE CHART ALONG WITH THE | | | REQUIRED LIGHTING CONTROLS. IN ADDITION TO THIS SHOW | | | THE LIGHTING CIRCUITS ON THE FLOOR PLAN BECAUSE AS | | | INDICATED IN NEC 700.12 THE EMERGENCY LIGHTING SHALL BE | | | TIED IN TO THE LIGHTING CIRCUIT OF THE AREA THEY | | | OCCUPY. | | | 4. THE STAIRWAYS CONTINUE TO BE MISSING THE REQUIRED | | | EMERGENCY LIGHTING. | | | 5. YOU SHALL SUBMIT MANUFACTURER SPEC SHEET FOR THE | | | TWH. | | | 6. THE RISER DIAGRAM FAILS TO SHOW THE REQUIRED | | | INTER-SYSTEM BONDING TERMINAL INDICATED IN NEC 250.94. | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | | RE-SUBMITTAL, PLEASE PROVIDE A RESPONSE LETTER | | | (NARRATIVE) ADDRESSING EACH ITEM AND THE PAGE NUMBER | | | WHERE THE CORRECTIONS APPEAR ALONG WITH THE STANDARD | | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK VOID | | | AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | | GREATLY APPRECIATED. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU, | | | MIKE ALBARRAN | | | ELECTRICAL PLANS EXAMINER | | | PH: 561-805-6746 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-01-06 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2016-01-06 |
Time |
19:21 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2016-01-06 |
Time |
17:39 |
Sent To |
|
|
| Notes |
| 2016-01-06 19:22:05 | THE PLANS FOR THE ABOVE MENTIONED REVISION HAS BEEN | | | REVIEWED FOR COMPLIANCE WITH THE EDITION OF THE NEC, | | | (NATIONAL ELECTRICAL CODE), FIRE CODES AND THE FBC, | | | (FLORIDA BUILDING CODE) AS WELL AS THE CITY OF WEST | | | PALM BEACH AMENDMENTS IN EFFECT AT THE TIME OF | | | SUBMITTAL. BELOW IS A LIST OF THE DEFICIENCIES NOTED. | | | | | | 1. NEC 300.21 SPREAD OF FIRE OR PRODUCTS OF COMBUSTION. | | | OPENINGS AROUND ELECTRICAL PENETRATIONS INTO OR THROUGH | | | FIRE-RESISTANT-RATED WALL, PARTITIONS, FLOORS OR | | | CEILINGS SHALL BE FIRE-STOPPED USING APPROVED METHODS | | | TO MAINTAIN THE FIRE RESISTANCE RATING. SEE FBC-B | | | SECTION 714. | | | 2. NEC 406.9(B) RECEPTACLES IN WET LOCATIONS. 15 AND 20 | | | AMPERE, 125 AND 250 VOLT RECEPTACLES INSTALLED IN A WET | | | LOCATION SHALL HAVE AN ENCLOSURE THAT IS WEATHERPROOF | | | WHETHER OR NOT THE ATTACHMENT PLUG CAP IS INSERTED. ALL | | | 15 AND 20 AMPERE, 125 AND 250 VOLT NONLOCKING | | | RECEPTACLES SHALL BE LISTED WEATHER-RESISTANT TYPE | | | ?WR?. | | | 3. NEC 700.12 (F) (4) - EMERGENCY LIGHTING SHALL BE FED | | | BY LIGHTING CIRCUIT OF SAME LOCAL AREA. *IF 3 OR MORE | | | LIGHTING CIRCUITS SUPPLY THE AREA, EM LIGHTS MAY BE ON | | | OWN CIRCUIT. | | | 4. STAIRS SHALL BE PROVIDED WITH EMERGENCY | | | ILLUMINATION. | | | 5. FBC-E C402.4.8 RECESSED LIGHTING. RECESSED LIGHTING | | | INSTALLED IN THE BUILDING THERMAL ENVELOPE SHALL BE IC | | | RATED AND BE SEALED TO LIMIT AIR LEAKAGE BETWEEN | | | CONDITIONED & UNCONDITIONED SPACES. | | | 6. NEC 300.50 UNDERGROUND INSTALLATIONS. (F) WHERE A | | | RACEWAY ENTERS FROM AN UNDERGROUND SYSTEM, THE ENDS | | | SHALL BE SEALED WITH A LISTED COMPOUND TO PREVENT THE | | | ENTRANCE OF MOISTURE OR GASES CONTACTING LIVE PARTS. | | | | | | WHEN RESUBMITTING, FOR A QUICKER RETURN ON YOUR | | | RE-SUBMITTAL, YOU ARE REQUIRED TO PROVIDE A RESPONSE | | | LETTER (NARRATIVE) ADDRESSING EACH ITEM ALONG WITH THE | | | STANDARD CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE | | | INSERT CORRECTED PAGES INTO THE SUBMITTAL PACKAGE. MARK | | | VOID AND LEAVE THE PREVIOUSLY REVIEWED SHEETS FOR | | | COMPARATIVE REVIEW. CLOUDING THE CHANGES WILL BE | | | GREATLY APPRECIATED. | | | | | | IF YOU HAVE FURTHER QUESTIONS, PLEASE DON?T HESITATE TO | | | CONTACT ME DIRECTLY. | | | | | | THANK YOU, | | | MIKE ALBARRAN | | | ELECTRICAL PLANS EXAMINER | | | PH: 561-805-6746 | | | EMAIL: [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2016-03-07 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-03-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-03-04 |
Time |
16:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2016-02-11 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-02-11 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-02-10 |
Time |
16:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2015-12-04 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2015-12-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2015-12-04 |
Time |
10:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2016-03-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-03-10 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-03-03 |
Time |
14:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-02-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-02-29 |
Time |
12:29 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-02-08 |
Time |
15:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-01-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-01-07 |
Time |
16:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2015-11-25 |
Time |
13:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2016-01-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2016-01-07 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2016-01-07 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2016-01-07 16:52:36 | GREEN CARD SHOWS FOUR RETAIL UNITS FIRST FLOOR; IMPACT | | | FEE ASSESSMENT NOT REQUIRED PER MICHELLE BONANNI | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2016-03-10 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-03-10 |
Time |
07:48 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-03-10 |
Time |
07:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2016-02-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-02-16 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-02-16 |
Time |
10:22 |
Sent To |
|
|
| Notes |
| 2016-02-16 10:49:42 | 2ND REVIEW: FBC 2014 MECHANICAL | | | PERMIT #15111031 | | | 2/16/16 | | | | | | 1) THE SUBMITTED AC CALCULATIONS ARE BASED ON DESIGN | | | TEMPERATURES FROM MIAMI FL. PLEASE REVISE THE | | | CALCULATIONS USING DESIGN TEMPERATURES FROM WEST PALM | | | BEACH- REFER TO ACCA MANUAL N- SEE SECTION C403.2.1 | | | FBC-14 ENERGY CONSERVATION | | | 2) PLEASE INDICATE THE DIRECTIONAL ORIENTATIONS OF THE | | | TENANT SPACES ON THE AC CALCULATIONS- SECTION C403.2.1. | | | 3) PLEASE PROVIDE AC EQUIPMENT SCHEDULES ON THE PLAN- | | | THE IS NO WAY TO VERIFY THE COMPLIANCE DATA FOR THE | | | SYSTEMS LISTED IN THE SUBMITTED ASHRAE 90.1 ENERGY COST | | | BUDGET OPTION FORM. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2015-12-01 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2015-12-01 |
Time |
15:33 |
Rev Time |
|
| Received By |
ccole |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2015-12-01 16:44:10 | 1ST REVIEW 2014 MECHANICAL | | | PERMIT #15111031 | | | 12/1/15 | | | | | | 1) PROVIDE AC COOLING AND HEATING LOAD CALCULATIONS IN | | | ACCORDANCE WITH ASHRAE/ACCA STANDARD 183 OR ACCA MANUAL | | | N- SEE SECTION C303.2.1 FBC-14 ENERGY CALCULATIONS. | | | 2) THE PLANS INDICATES A CHANGE IN OCCUPANCY | | | CLASSIFICATION FROM THE PREVIOUS ASSEMBLY OCCUPANCY TO | | | FOUR NEW MERCANTILE OCCUPANCIES- COMPLIANCE WITH THE | | | FBC-14 ENERGY CONSERVATION CODE IS REQUIRED. PLEASE SEE | | | SECTION C101.4.4 AND SUBMIT EITHER THE PRESCRIPTIVE | | | COMPLIANCE FORM R402, OR THE ENERGY GAUGE PERFORMANCE | | | BASED FORM 506-2014. | | | 3) SHEET A-8: THE DOOR SCHEDULE INDICATES WOOD LOUVERED | | | DOORS FOR THE NEW AIR HANDLER CLOSETS- REFER TO SECTION | | | 602 FBC-14 MECHANICAL, AND C403.2.7.2 FBC-14 ENERGY | | | CONSERVATION AND PROVIDE NON-COMBUSTIBLE DOORS. | | | 4) M-1: PROVIDE TOILET ROOM EXHAUST DUCT DETAILS OR | | | NOTES FOR RETAIL SPACES #2 & #3. | | | 5) M-2: PROVIDE THE WIND LOAD DESIGN CRITERIA FOR TIE | | | DOWN OF THE CONDENSERS TO THE EXISTING STANDS- SEE | | | SECTION 301.15 FBC-14 MECHANICAL. | | | 6) M-2: THE MINIMUM 18" SPACING BETWEEN THE CONDENSERS | | | ON THE ROOF STANDS MUST BE VERIFIED TO BE IN ACCORDANCE | | | WITH THE MANUFACTURER'S RECOMMENDATIONS- PLEASE SUBMIT | | | DOCUMENTATION. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2016-03-09 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-03-09 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-03-09 |
Time |
15:25 |
Sent To |
|
|
| Notes |
| 2016-03-09 15:27:32 | PLUMBING PROVISO | | | PLAN APPROVED WITH EXCEPTION !! FAILURE TO CORRECT | | | LISTED DEFICIENCIES PRIOR TO INSPECTION WILL RESULT IN | | | FAILED INSPECTIONS AND REINSPECTION FEES | | | 1. HOT WATER REQUIRED AT SERVICE SINK. PER FBC PL. SEC | | | 607.1 | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2016-02-19 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-02-19 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-02-19 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2016-02-19 16:56:13 | 2ND REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. UNDER THIS PERMIT EACH UNIT IS REQUIRED TO COMPLY | | | WITH FBC PL SEC 403.1 TABLE 403.1 | | | | | | (A) WATER FOUNTAINS ARE REQUIRED AND SHALL COMPLY WITH | | | FBC ACC SEC. 602+307 AND FBC PL SEC. 410.2 | | | | | | (B) A SERVICE SINK. | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2015-12-06 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2015-12-06 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2015-12-06 |
Time |
11:45 |
Sent To |
|
|
| Notes |
| 2015-12-06 11:56:25 | 1ST REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1.WATER FOUNTAINS ARE REQUIRED PER FBC PL SEC 404.1 AND | | | TABLE 403.1. SHALL COMPLY WITH FBC ACC. SEC 602 | | | 2.THE WATER CLOSET SHALL BE POSITIONED WITH A WALL OR | | | PARTITION TO THE REAR AND TO ONE SIDE. THE CENTERLINE | | | OF THE WATER CLOSET SHALL BE 16 INCHES (405 MM) MINIMUM | | | TO 18 INCHES (455 MM) MAXIMUM FROM THE SIDE WALL OR | | | PARTITION. PER FBC ACC SEC 604.2 | | | 3. GRAB BARS SHALL BE MEASURED TO THE TOP OF THE | | | GRIPPING SURFACE TO FINISHED FLOOR. PER FBC ACC. SEC | | | 609.4 | | | 4.HOT WATER OR TEMPERED WATER SHALL BE SUPPLIED FOR | | | BATHING AND WASHING PURPOSES INCLUDING HAND WASHING | | | .PER FBC PL SEC.607.1 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2016-03-10 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2016-03-10 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2016-03-10 |
Time |
08:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2016-02-18 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2016-02-18 |
Time |
18:03 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2016-02-18 |
Time |
08:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2015-12-07 |
|
|
Cont ID |
|
| Sent By |
dkittred |
Date |
2015-12-07 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
dkittred |
Date |
2015-12-07 |
Time |
10:38 |
Sent To |
|
|
| Notes |
| 2015-12-07 16:46:43 | PLANNING AND ZONING COMMENTS: ***FAILED*** | | | | | | 12/7/15 | | | | | | 1. PROVIDE EVIDENCE THAT THE PROPOSED AC UNITS ON THE | | | ROOF WILL NOT BE VISIBLE FROM THE STREET. IF THE UNITS | | | WILL BE HIGHER THAN THE PARAPET, SCREENING WILL NEED TO | | | BE PROVIDED AROUND THE UNITS AND MUST BE SHOWN ON THE | | | PLAN. | | | | | | GENERAL COMMENTS: | | | | | | A. PROPOSED AWNINGS WILL REQUIRED A SEPARATE PERMIT, | | | PLAN REVIEW, AND FEE. PLEASE BE ADVISED THAT AT TIME OF | | | SUBMITTAL FOR THE AWNINGS, A PROPERTY SURVEY MUST BE | | | SUBMITTED TO DEMONSTRATE WHETHER OR NOT THE AWNINGS | | | ENCROACH OVER THE PUBLIC RIGHT-OF-WAY. ANY ENCROACHMENT | | | OF THE AWNINGS OVER THE PUBLIC RIGHT-OF-WAY ALONG DIXIE | | | HIGHWAY WILL REQUIRE APPROVAL BY FDOT AS DIXIE HIGHWAY | | | IS A STATE ROAD. | | | | | | B. PLEASE BE ADVISED THAT WHEN RENOVATION COSTS EXCEED | | | 50% THE VALUE OF THE STRUCTURE, A LANDSCAPE PLAN IN | | | ACCORDANCE WITH ZLDR ARTICLE XIV WILL BE REQUIRED TO BE | | | SUBMITTED TO BRING THE SITE INTO COMPLIANCE WITH | | | LANDSCAPING REQUIREMENTS. AS OF THIS PERMIT, THE | | | PROPOSED CONSTRUCTION COST IS $186,000 WHICH IS JUST | | | UNDER 50% THE VALUE OF THE STRUCTURE ( $376,860) | | | ACCORDING TO THE PALM BEACH COUNTY PROPERTY APPRAISER | | | RECORDS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT: | | | | | | DANIELLE J. KITTREDGE, AICP | | | SENIOR PLANNER | | | PLANNING & ZONING DIVISION | | | PHONE: (561)-822-1443 | | | EMAIL: [email protected] | | | |
|
|