Plan Review Details - Permit 15111025
| Plan Review Stops For Permit 15111025 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2015-12-17 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2015-12-17 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
2015-12-17 |
Time |
16:06 |
Sent To |
I |
|
| Notes |
| 2015-12-17 16:14:03 | 1ST REVIEW: FBC 2014 5TH ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 516-805-6700 | | | [email protected] | | | ALTERNATE CONTACT | | | MIKE ALBARRAN | | | 561-805-6746 | | | [email protected] | | | | | | | | | PROVISO | | | | | | (B) WET LOCATIONS. THE INTERIOR OF ENCLOSURES OR | | | RACEWAYS | | | INSTALLED UNDERGROUND SHALL BE CONSIDERED TO BE A WET | | | LOCATION. | | | INSULATED CONDUCTORS AND CABLES INSTALLED IN THESE | | | ENCLOSURES | | | OR RACEWAYS IN UNDERGROUND INSTALLATIONS SHALL BE | | | LISTED FOR USE | | | IN WET LOCATIONS AND SHALL COMPLY WITH 310.10(C). ANY | | | CONNECTIONS | | | OR SPLICES IN AN UNDERGROUND INSTALLATION SHALL BE | | | APPROVED | | | FOR WET LOCATIONS. | | | | | | (1) GENERAL. IN INDOOR LOCATIONS OTHER THAN DWELLINGS | | | AND | | | ASSOCIATED ACCESSORY STRUCTURES, FLUORESCENT LUMINAIRES | | | THAT UTILIZE | | | DOUBLE-ENDED LAMPS AND CONTAIN BALLAST(S) THAT CAN BE | | | SERVICED IN PLACE SHALL HAVE A DISCONNECTING MEANS | | | EITHER INTERNAL | | | OR EXTERNAL TO EACH LUMINAIRE. FOR EXISTING INSTALLED | | | LUMINAIRES | | | WITHOUT DISCONNECTING MEANS, AT THE TIME A BALLAST IS | | | REPLACED, A DISCONNECTING MEANS SHALL BE INSTALLED. THE | | | LINE | | | SIDE TERMINALS OF THE DISCONNECTING MEANS SHALL BE | | | GUARDED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2015-12-03 |
|
|
Cont ID |
|
| Sent By |
mvaldes |
Date |
2015-12-03 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
mvaldes |
Date |
2015-12-03 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2015-12-03 14:26:02 | 1ST REVIEW: FBC 2014 5TH ED. NEC 2011 | | | MARIO VALDES | | | ELECTRICAL PLAN EXAMINER | | | 516-805-6700 | | | [email protected] | | | ALTERNATE CONTACT | | | PHIL PETTY | | | 561-805-6742 | | | [email protected] | | | | | | | | | | | | 600.6 DISCONNECTS. EACH SIGN AND OUTLINE LIGHTING | | | SYSTEM, | | | FEEDER CIRCUIT OR BRANCH CIRCUIT SUPPLYING A SIGN, | | | OUTLINE | | | LIGHTING SYSTEM, OR SKELETON TUBING SHALL BE CONTROLLED | | | BY AN | | | EXTERNALLY OPERABLE SWITCH OR CIRCUIT BREAKER THAT | | | OPENS ALL | | | UNGROUNDED CONDUCTORS AND CONTROLS NO OTHER LOAD. THE | | | SWITCH OR CIRCUIT BREAKER SHALL OPEN ALL UNGROUNDED | | | CONDUCTORS | | | SIMULTANEOUSLY ON MULTI-WIRE BRANCH CIRCUITS IN | | | ACCORDANCE | | | WITH 210.4(B). SIGNS AND OUTLINE LIGHTING SYSTEMS | | | LOCATED WITHIN FOUNTAINS SHALL HAVE THE DISCONNECT | | | LOCATED | | | IN ACCORDANCE WITH 680.12. | | | | | | (1) WITHIN SIGHT OF THE SIGN. THE DISCONNECTING MEANS | | | SHALL | | | BE WITHIN SIGHT OF THE SIGN OR OUTLINE LIGHTING SYSTEM | | | THAT IT | | | CONTROLS. WHERE THE DISCONNECTING MEANS IS OUT OF THE | | | LINE OF | | | SIGHT FROM ANY SECTION THAT IS ABLE TO BE ENERGIZED, | | | THE DISCONNECTING | | | MEANS SHALL BE CAPABLE OF BEING LOCKED IN THE OPEN | | | POSITION. THE PROVISION FOR LOCKING OR ADDING A LOCK TO | | | THE | | | DISCONNECTING MEANS MUST REMAIN IN PLACE AT THE SWITCH | | | OR | | | CIRCUIT BREAKER WHETHER THE LOCK IS INSTALLED OR NOT. | | | PORTABLE | | | MEANS FOR ADDING A LOCK TO THE SWITCH OR CIRCUIT | | | BREAKER SHALL | | | NOT BE PERMITTED. | | | | | | | | | ENERGY CODE SECTION C 504 | | | FBC-EC 505.2.4 - PROVIDE A TIME CLOCK OR ASTRONOMICAL | | | SWITCH TO TURN OFF DURING DAYLIGHT HOURS | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2015-12-17 |
|
|
Cont ID |
|
| Sent By |
albarran |
Date |
2015-12-17 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
albarran |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2015-12-17 16:21:06 | 12/17/15 PASSED ELECTRICAL WITH PROVISOS AS NOTED. | | | CONTRACTOR NOTIFIED VIA EMAIL. SENT TO SMALL DENIED BIN | | | "S". MA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2015-12-03 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2015-12-03 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2015-11-25 |
Time |
13:28 |
Sent To |
|
|
| Notes |
| 2015-11-25 13:28:17 | ELEC <5K |
|
|
|
Account Summary | Usage Policy | Privacy Policy