Plan Review Details - Permit 15111020
| Plan Review Stops For Permit 15111020 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2017-02-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-02-06 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-02-06 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2018-07-09 16:36:10 | PROVISO 4-1 WAS RESOLVED UNDER SUBMITTAL 17110020 (REG) | | 2017-02-06 14:01:03 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15111020 | | | ADD: 1100 S. FLAGLER DR. | | | CONT: SUFFOLK CONSTRUCTION CO. | | | TEL: 561-832-1616 | | | E-MAIL: [email protected] / ED HANRATTY | | | | | | 2010 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 5TH REVIEW | | | DATE: MON. FEB. 06/ 2017 | | | ACTION:BUILDING PROVISO | | | | | | | | | NOTE: THIS REVIEW IS GOING TO BE COMPLETED AS A MIXED | | | USE BUILDING,(FEMA REGULATIONS) AND THE REQUIREMENTS AS | | | SUCH. 2010 FBC-B 1612.4 DESIGN & CONSTRUCTION SHALL BE | | | IN ACCORDANCE WITH ASCE 24-05. ASCE 24-05 TABLE 6-1 | | | MINIMUM ELEVATION OF FLOODPROOFING, RELATIVE TO THE | | | BASE FLOOD (BFE) OR DESIGN FLOOD ELEVATION (DFE)- | | | OUTSIDE OF HIGH RISK FLOOD HAZARD AREAS. STRUCTURE | | | CATEGORY- II (FOOTNOTE) C. (C) DRY FLOODPROOFING OF | | | RESIDENTIAL BUILDINGS AND RESIDENTIAL PORTIONS OF MIXED | | | USE BUILDINGS SHALL NOT BE PERMITTED. | | | | | | | | | 1) BUILDING PROVISO: DEFERRED SUBMITTAL. ELEVATOR | | | PRODUCT DATA SHEET FOR OTIS GEN 2 ELEVATOR. | | | | | | FEMA TECHNICAL BULLETIN 4-93. FEMA REGULATION | | | 60.3(A)(3) IF A PROPOSED BUILDING SITE WILL BE | | | REASONABLY SAFE FROM FLOODING. IF A PROPOSED BUILDING | | | SITE IS IN A FLOOD PRONE AREA, ALL NEW CONSTRUCTION AND | | | SUBSTANTIAL IMPROVEMENTS SHALL? BE CONSTRUCTED WITH | | | MATERIALS RESISTANT TO FLOOD DAMAGE,(III) BE | | | CONSTRUCTED BY METHODS AND PRACTICES THAT MINIMIZE | | | FLOOD DAMAGES, AND (IV) BE CONSTRUCTED WITH | | | ELECTRICAL... EQUIPMENT AND OTHER SERVICES FACILITIES | | | THAT ARE DESIGNED AND / OR LOCATED SO AS TO PREVENT | | | WATER DAMAGE FROM ENTERING OR ACCUMULATING WITHIN THE | | | COMPONENTS DURING CONDITIONS OF FLOODING. | | | TO KEEP THE ELEVATOR CABS FROM HAVING SUBSTANTIAL | | | DAMAGE FROM FLOODWATERS, IS THERE A INTERLOCKING | | | CONTROL OR FLOAT SWITCH THAT WHEN ACTIVATED WILL KEEP | | | THE CAB FROM DESCENDING INTO THE FLOODWATERS. | | | | | | 2) PROVISO: ANY EUROPEAN CAR LIFT SYSTEM WILL NEED TO | | | SUBMIT PRODUCT LISTINGS WHERE THEY HAVE AN NRTL | | | (NATIONALLY RECOGNIZED TESTING LABORATORY) ACCREDITED | | | BY THE US AUTHORITY OCCUPATIONAL SAFETY AND HEALTH | | | ADMINISTRATION AND STAMPED FOR US MARKETS. | | | | | | 3) BUILDING PROVISO: THE PLANS SHOW AT THE ENTRY LEVEL | | | OF THE LOBBY A RECEPTION/ REGISTRATION DESK. PLEASE | | | PROVIDE COMPLIANCE WITH FAIR HOUSING SPECIFICATION OF | | | ANSI 4.31 ALSO SEE REACH RANGES. | | | | | | 4) BUILDING PROVISO: DEFERRED SUBMITTALS : TEST REPORTS | | | SHOWING COMPLIANCE WITH: | | | | | | 4)(1) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND. | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | | | 4)(2) FBC-B 2014 1207.2 AIR-BORNE SOUND. | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | | E 90. | | | | | | 4)(3) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2. | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | | | 5) BUILDING PROVISO: DEFERRED SUBMITTALS: SHEET | | | 431-M4-01 MECHANICAL DETAILS EQUIPMENT SUPPORT CURB | | | DETAIL & THYBAR VIBRATION CURB III DETAIL FOR OAU-1 & | | | 2. PLEASE PROVIDE THE PRODUCT APPROVALS FOR CURB | | | DETAILS. TO BE REVIEWED BY THE STRUCTURAL ENGINEER OF | | | RECORD, AND WITH THEIR SHOP DRAWING STAMP OF APPROVAL. | | | PLEASE NOTE THE STRUCTURAL ANCHOR TO THE BASE OR | | | SUPPORT AS WELL AS THE UNIT TO THE CURB FOR MOMENT OF | | | OVERTURNING, WILL NEED TO BE DESIGNED BY THE STRUCTURAL | | | ENGINEER OR HIS DELEGATE WITH THE STRUCTURAL ENGINEERS | | | APPROVAL BEFORE SUBMITTAL TO THE BUILDING DEPARTMENT | | | FOR REVIEW. | | | FL 61G-15-30.006 (3) THE DELEGATED ENGINEER SHALL | | | FORWARD THE DELEGATED ENGINEERING DOCUMENTS TO THE | | | ENGINEER OF RECORD FOR REVIEW. | | | | | | 6)BUILDING PROVISO: DEFERRED SUBMITTAL FOR | | | ARCHITECTURAL TRIM AND EMBELLISHMENTS METAL FINS ON | | | LEVEL 26. 1407.5 APPROVAL. RESULTS OF APPROVED TESTS OR | | | AN ENGINEERING ANALYSIS SHALL BE SUBMITTED TO THE | | | BUILDING OFFICIAL TO VERIFY COMPLIANCE WITH THE | | | REQUIREMENTS OF CHAPTER 16 FOR WIND LOADS. 1407.6 | | | WEATHER RESISTANCE. IF DELEGATED ENGINEERING THEN THE | | | DOCUMENTS NEED TO BE FORWARDED TO THE ENGINEER OF | | | RECORD FOR REVIEW AND APPROVAL BEFORE SUBMITTING TO THE | | | BUILDING DEPARTMENT. 61G15-30.003. | | | | | | 7) BUILDING PROVISO: DEFERRED SUBMITTAL FOR THE TERRA | | | COTTA WALL CLADDING UNITS. FOR ARCHITECTURAL TRIM AND | | | EMBELLISHMENTS THE TERRA COTTA UNITS WILL NEED TO | | | COMPLY WITH 2010 FBC-B 1407.5 APPROVAL. RESULTS OF | | | APPROVED TESTS OR AN ENGINEERING ANALYSIS SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO VERIFY COMPLIANCE | | | WITH THE REQUIREMENTS OF CHAPTER 16 FOR WIND LOADS. | | | 1407.6 WEATHER RESISTANCE. IF DELEGATED ENGINEERING | | | THEN THE DOCUMENTS NEED TO BE FORWARDED TO THE ENGINEER | | | OF RECORD FOR REVIEW AND APPROVAL BEFORE SUBMITTING TO | | | THE BUILDING DEPARTMENT. 61G15-30.003. | | | | | | 8) BUILDING PROVISO: DEFERRED SUBMITTAL | | | POLYISOCYANURATE BOARD. WITH SINGLE PLY RECOVERY BOARD | | | AND SINGLE PLY PVC ROOFING MEMBRANE ROOFING. PLEASE | | | PROVIDE THE PRODUCT APPROVALS FOR EACH OF THE MEMBERS. | | | FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY ALL ROOFING | | | SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES FOR ROOF | | | ZONE # 1. REVIEW THE PRODUCT APPROVAL LIMITATIONS, IF | | | ENHANCED FASTENING IS ALLOWED FOR ROOF ZONES 2 & 3. | | | FASTENER DENSITIES SHALL BE INCREASED FOR BOTH | | | INSULATION & THE BASE SHEET AS CALCULATED IN COMPLIANCE | | | WITH ROOFING APPLICATION STANDARDS RAS 117. CALCULATION | | | PREPARED, SIGNED AND SEALED BY A FLORIDA REGISTERED | | | PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT. | | | FL 61G-15-30.006 (3) THE DELEGATED ENGINEER SHALL | | | FORWARD THE DELEGATED ENGINEERING DOCUMENTS TO THE | | | ENGINEER OF RECORD FOR REVIEW. | | | | | | 9)BUILDING PROVISO: DEFERRED SUBMITTALS. DETAILS 3 & 4 | | | BOTH SHOW A TILE DECK ABOVE THE ROOFING SYSTEM. THE | | | ROOFING SYSTEM WELL NEED TO PROVIDE PRODUCT APPROVALS | | | FOR WIND AS WELL AS ENGINEERING FOR THE TILE DECK | | | INSTALLATION THEY WILL MEET THE WIND LOADS FOR THE | | | LOCATION ON THE BUILDING.2010 FBC-B COMPONENTS AND | | | CLADDING. 1609.6.4.4.1 COMPONENTS & CLADDING. | | | | | | 10) BUILDING PROVISO: DEFERRED SUBMITTAL. CANOPY | | | SYSTEMS. ADDITIONAL ENGINEERING SHEETS (SHOP DRAWINGS) | | | TO BE SUBMITTED AS A DEFERRED SUBMITTAL. PLEASE ALSO | | | PROVIDE HOW CODE COMPLIANCE WITH 2010 FBC-B 2405.2 | | | ALLOWABLE GLAZING MATERIALS AND LIMITATIONS WILL BE | | | COMPLIED WITH. FL 61G-15-30.006 (3) THE DELEGATED | | | ENGINEER SHALL FORWARD THE DELEGATED ENGINEERING | | | DOCUMENTS TO THE ENGINEER OF RECORD FOR REVIEW. | | | | | | 11) BUILDING PROVISO: 107.3.4.2 DEFERRED SUBMITTALS. | | | 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING | | | | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. ROOF HATCHES. | | | (B) WINDOWS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, CURBS, INTAKE AND | | | EXHAUST FANS ? | | | (E) SHUTTERS | | | (F) SKYLIGHTS | | | (G) PRE-ENGINEERED A/C STANDS | | | 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA | | | RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN WRITING BY | | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2017-01-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-01-30 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-01-30 |
Time |
|
Sent To |
|
|
| Notes |
| 2017-01-30 10:48:26 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15111020 | | | ADD: 1100 S. FLAGLER DR. | | | CONT: SUFFOLK CONSTRUCTION CO. | | | TEL: 561-832-1616 | | | E-MAIL: [email protected] / ED HANRATTY | | | | | | 2010 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 4TH REVIEW | | | DATE: MON. JAN. 30/ 2017 | | | ACTION: DENIED | | | | | | | | | NOTE: THIS REVIEW IS GOING TO BE COMPLETED AS A MIXED | | | USE BUILDING,(FEMA REGULATIONS) AND THE REQUIREMENTS AS | | | SUCH. 2010 FBC-B 1612.4 DESIGN & CONSTRUCTION SHALL BE | | | IN ACCORDANCE WITH ASCE 24-05. | | | ASCE 24-05 TABLE 6-1 MINIMUM ELEVATION OF | | | FLOODPROOFING, RELATIVE TO THE BASE FLOOD (BFE) OR | | | DESIGN FLOOD ELEVATION (DFE)- OUTSIDE OF HIGH RISK | | | FLOOD HAZARD AREAS. STRUCTURE CATEGORY- II (FOOTNOTE) | | | C. (C) DRY FLOODPROOFING OF RESIDENTIAL BUILDINGS AND | | | RESIDENTIAL PORTIONS OF MIXED USE BUILDINGS SHALL NOT | | | BE PERMITTED. | | | | | | 1) DENIED!!!!!!!! 2ND REQUEST!!!!!!. PLANS STILL SHOW | | | AN OPENING WITHIN 10 FEET OF THE EXIT STAIR # 9. SEE | | | 079-A2-0P1, 182-A5-28 & 182-A5-28 NOR THE STRUCTURAL | | | SHEETS 358-S2-0P1. | | | THE MECHANICAL SHEET 397-M2-)P1 SHOWS (2) FIRE DAMPERS | | | PGEF P2-1A & PGP2-1B THESE FIRE DAMPERS DO NOT LINE UP | | | OR ARE SIZED FOR THE EXTERIOR WALL OPENINGS SEPARATING | | | THE EXTERIOR OF THE BUILDING. THE LAST DATE THIS PLAN | | | WAS UPDATED WAS 11/22/2016. THE BRISTOL MEETING | | | ADDRESSING THIS ISSUE WAS ON JAN 11/2017. | | | , MECHANICAL REVIEW HAS ASKED THIS COMMENT REPEATEDLY | | | SEE SHEET 182-A5-28 THE DETAILS SHOW 2 ISSUES: | | | 1A) THE EXTERIOR EXIT STAIR SHOWS LOUVERS IN THE | | | EXTERIOR WALL AND WITHIN 10 FEET OF THE EXTERIOR | | | STAIRS. PLEASE REVIEW SECTION 2010 FBC-B 1026.6 | | | EXTERIOR STAIRWAY AND RAMP PROTECTION. | | | EXTERIOR EXIT STAIRWAYS AND RAMPS SHALL BE SEPARATED | | | FROM THE INTERIOR OF THE BUILDING AS REQUIRED IN | | | SECTION 1022.2. OPENINGS SHALL BE LIMITED TO THOSE | | | NECESSARY FOR EGRESS FROM NORMALLY OCCUPIED SPACES. | | | 1) BUILDING PROVISO: DEFERRED SUBMITTAL. ELEVATOR | | | PRODUCT DATA SHEET FOR OTIS GEN 2 ELEVATOR. | | | | | | FEMA TECHNICAL BULLETIN 4-93. FEMA REGULATION | | | 60.3(A)(3) IF A PROPOSED BUILDING SITE WILL BE | | | REASONABLY SAFE FROM FLOODING. IF A PROPOSED BUILDING | | | SITE IS IN A FLOOD PRONE AREA, ALL NEW CONSTRUCTION AND | | | SUBSTANTIAL IMPROVEMENTS SHALL? BE CONSTRUCTED WITH | | | MATERIALS RESISTANT TO FLOOD DAMAGE,(III) BE | | | CONSTRUCTED BY METHODS AND PRACTICES THAT MINIMIZE | | | FLOOD DAMAGES, AND (IV) BE CONSTRUCTED WITH | | | ELECTRICAL... EQUIPMENT AND OTHER SERVICES FACILITIES | | | THAT ARE DESIGNED AND / OR LOCATED SO AS TO PREVENT | | | WATER DAMAGE FROM ENTERING OR ACCUMULATING WITHIN THE | | | COMPONENTS DURING CONDITIONS OF FLOODING. | | | TO KEEP THE ELEVATOR CABS FROM HAVING SUBSTANTIAL | | | DAMAGE FROM FLOODWATERS, IS THERE A INTERLOCKING | | | CONTROL OR FLOAT SWITCH THAT WHEN ACTIVATED WILL KEEP | | | THE CAB FROM DESCENDING INTO THE FLOODWATERS. | | | | | | 2) PROVISO: ANY EUROPEAN CAR LIFT SYSTEM WILL NEED TO | | | SUBMIT PRODUCT LISTINGS WHERE THEY HAVE AN NRTL | | | (NATIONALLY RECOGNIZED TESTING LABORATORY) ACCREDITED | | | BY THE US AUTHORITY OCCUPATIONAL SAFETY AND HEALTH | | | ADMINISTRATION AND STAMPED FOR US MARKETS. | | | | | | 3) BUILDING PROVISO: THE PLANS SHOW AT THE ENTRY LEVEL | | | OF THE LOBBY A RECEPTION/ REGISTRATION DESK. PLEASE | | | PROVIDE COMPLIANCE WITH FAIR HOUSING SPECIFICATION OF | | | ANSI 4.31 ALSO SEE REACH RANGES. | | | | | | 4) BUILDING PROVISO: DEFERRED SUBMITTALS : TEST REPORTS | | | SHOWING COMPLIANCE WITH: | | | | | | 4)(1) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND. | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | | | 4)(2) FBC-B 2014 1207.2 AIR-BORNE SOUND. | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | | E 90. | | | | | | 4)(3) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2. | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | | | 5) BUILDING PROVISO: DEFERRED SUBMITTALS: SHEET | | | 431-M4-01 MECHANICAL DETAILS EQUIPMENT SUPPORT CURB | | | DETAIL & THYBAR VIBRATION CURB III DETAIL FOR OAU-1 & | | | 2. PLEASE PROVIDE THE PRODUCT APPROVALS FOR CURB | | | DETAILS. TO BE REVIEWED BY THE STRUCTURAL ENGINEER OF | | | RECORD, AND WITH THEIR SHOP DRAWING STAMP OF APPROVAL. | | | PLEASE NOTE THE STRUCTURAL ANCHOR TO THE BASE OR | | | SUPPORT AS WELL AS THE UNIT TO THE CURB FOR MOMENT OF | | | OVERTURNING, WILL NEED TO BE DESIGNED BY THE STRUCTURAL | | | ENGINEER OR HIS DELEGATE WITH THE STRUCTURAL ENGINEERS | | | APPROVAL BEFORE SUBMITTAL TO THE BUILDING DEPARTMENT | | | FOR REVIEW. | | | FL 61G-15-30.006 (3) THE DELEGATED ENGINEER SHALL | | | FORWARD THE DELEGATED ENGINEERING DOCUMENTS TO THE | | | ENGINEER OF RECORD FOR REVIEW. | | | | | | 6)BUILDING PROVISO: DEFERRED SUBMITTAL FOR | | | ARCHITECTURAL TRIM AND EMBELLISHMENTS METAL FINS ON | | | LEVEL 26. 1407.5 APPROVAL. RESULTS OF APPROVED TESTS OR | | | AN ENGINEERING ANALYSIS SHALL BE SUBMITTED TO THE | | | BUILDING OFFICIAL TO VERIFY COMPLIANCE WITH THE | | | REQUIREMENTS OF CHAPTER 16 FOR WIND LOADS. 1407.6 | | | WEATHER RESISTANCE. IF DELEGATED ENGINEERING THEN THE | | | DOCUMENTS NEED TO BE FORWARDED TO THE ENGINEER OF | | | RECORD FOR REVIEW AND APPROVAL BEFORE SUBMITTING TO THE | | | BUILDING DEPARTMENT. 61G15-30.003. | | | | | | 7) BUILDING PROVISO: DEFERRED SUBMITTAL FOR THE TERRA | | | COTTA WALL CLADDING UNITS. FOR ARCHITECTURAL TRIM AND | | | EMBELLISHMENTS THE TERRA COTTA UNITS WILL NEED TO | | | COMPLY WITH 2010 FBC-B 1407.5 APPROVAL. RESULTS OF | | | APPROVED TESTS OR AN ENGINEERING ANALYSIS SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO VERIFY COMPLIANCE | | | WITH THE REQUIREMENTS OF CHAPTER 16 FOR WIND LOADS. | | | 1407.6 WEATHER RESISTANCE. IF DELEGATED ENGINEERING | | | THEN THE DOCUMENTS NEED TO BE FORWARDED TO THE ENGINEER | | | OF RECORD FOR REVIEW AND APPROVAL BEFORE SUBMITTING TO | | | THE BUILDING DEPARTMENT. 61G15-30.003. | | | | | | 8) BUILDING PROVISO: DEFERRED SUBMITTAL | | | POLYISOCYANURATE BOARD. WITH SINGLE PLY RECOVERY BOARD | | | AND SINGLE PLY PVC ROOFING MEMBRANE ROOFING. PLEASE | | | PROVIDE THE PRODUCT APPROVALS FOR EACH OF THE MEMBERS. | | | FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY ALL ROOFING | | | SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES FOR ROOF | | | ZONE # 1. REVIEW THE PRODUCT APPROVAL LIMITATIONS, IF | | | ENHANCED FASTENING IS ALLOWED FOR ROOF ZONES 2 & 3. | | | FASTENER DENSITIES SHALL BE INCREASED FOR BOTH | | | INSULATION & THE BASE SHEET AS CALCULATED IN COMPLIANCE | | | WITH ROOFING APPLICATION STANDARDS RAS 117. CALCULATION | | | PREPARED, SIGNED AND SEALED BY A FLORIDA REGISTERED | | | PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT. | | | FL 61G-15-30.006 (3) THE DELEGATED ENGINEER SHALL | | | FORWARD THE DELEGATED ENGINEERING DOCUMENTS TO THE | | | ENGINEER OF RECORD FOR REVIEW. | | | | | | 9)BUILDING PROVISO: DEFERRED SUBMITTALS. DETAILS 3 & 4 | | | BOTH SHOW A TILE DECK ABOVE THE ROOFING SYSTEM. THE | | | ROOFING SYSTEM WELL NEED TO PROVIDE PRODUCT APPROVALS | | | FOR WIND AS WELL AS ENGINEERING FOR THE TILE DECK | | | INSTALLATION THEY WILL MEET THE WIND LOADS FOR THE | | | LOCATION ON THE BUILDING.2010 FBC-B COMPONENTS AND | | | CLADDING. 1609.6.4.4.1 COMPONENTS & CLADDING. | | | | | | 10) BUILDING PROVISO: DEFERRED SUBMITTAL. CANOPY | | | SYSTEMS. ADDITIONAL ENGINEERING SHEETS (SHOP DRAWINGS) | | | TO BE SUBMITTED AS A DEFERRED SUBMITTAL. PLEASE ALSO | | | PROVIDE HOW CODE COMPLIANCE WITH 2010 FBC-B 2405.2 | | | ALLOWABLE GLAZING MATERIALS AND LIMITATIONS WILL BE | | | COMPLIED WITH. FL 61G-15-30.006 (3) THE DELEGATED | | | ENGINEER SHALL FORWARD THE DELEGATED ENGINEERING | | | DOCUMENTS TO THE ENGINEER OF RECORD FOR REVIEW. | | | | | | 11) BUILDING PROVISO: 107.3.4.2 DEFERRED SUBMITTALS. | | | 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING | | | | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. ROOF HATCHES. | | | (B) WINDOWS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, CURBS, INTAKE AND | | | EXHAUST FANS ? | | | (E) SHUTTERS | | | (F) SKYLIGHTS | | | (G) PRE-ENGINEERED A/C STANDS | | | 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA | | | RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN WRITING BY | | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2016-12-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-12-21 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-12-19 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2016-12-21 12:10:40 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15111020 | | | ADD: 1100 S. FLAGLER DR. | | | CONT: SUFFOLK CONSTRUCTION CO. | | | TEL: 561-832-1616 | | | E-MAIL: [email protected] / ED HANRATTY | | | | | | 2010 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 3RD REVIEW | | | DATE: WED. DEC. 21/ 2016 | | | ACTION: DENIED | | | | | | | | | NOTE: THIS REVIEW IS GOING TO BE COMPLETED AS A MIXED | | | USE BUILDING,(FEMA REGULATIONS) AND THE REQUIREMENTS AS | | | SUCH. 2010 FBC-B 1612.4 DESIGN & CONSTRUCTION SHALL BE | | | IN ACCORDANCE WITH ASCE 24-05. | | | ASCE 24-05 TABLE 6-1 MINIMUM ELEVATION OF | | | FLOODPROOFING, RELATIVE TO THE BASE FLOOD (BFE) OR | | | DESIGN FLOOD ELEVATION (DFE)- OUTSIDE OF HIGH RISK | | | FLOOD HAZARD AREAS. STRUCTURE CATEGORY- II (FOOTNOTE) | | | C. (C) DRY FLOODPROOFING OF RESIDENTIAL BUILDINGS AND | | | RESIDENTIAL PORTIONS OF MIXED USE BUILDINGS SHALL NOT | | | BE PERMITTED. | | | | | | 1) NEW BUILDING COMMENT, MECHANICAL REVIEW HAS ASKED | | | THIS COMMENT REPEATEDLY SEE SHEET 182-A5-28 THE DETAILS | | | SHOW 2 ISSUES: | | | 1A) THE EXTERIOR EXIT STAIR SHOWS LOUVERS IN THE | | | EXTERIOR WALL AND WITHIN 10 FEET OF THE EXTERIOR | | | STAIRS. PLEASE REVIEW SECTION 2010 FBC-B 1026.6 | | | EXTERIOR STAIRWAY AND RAMP PROTECTION. | | | EXTERIOR EXIT STAIRWAYS AND RAMPS SHALL BE SEPARATED | | | FROM THE INTERIOR OF THE BUILDING AS REQUIRED IN | | | SECTION 1022.2. OPENINGS SHALL BE LIMITED TO THOSE | | | NECESSARY FOR EGRESS FROM NORMALLY OCCUPIED SPACES. | | | | | | 1B) DETAILS SHOW REENTRY INTO THE BUILDING, THIS DESIGN | | | DOES NOT COMPLY WITH FBC-B 1027.1 THE EXIT DISCHARGE | | | SHALL NOT REENTER A BUILDING. | | | | | | | | | 1) BUILDING PROVISO: DEFERRED SUBMITTAL. ELEVATOR | | | PRODUCT DATA SHEET FOR OTIS GEN 2 ELEVATOR. | | | | | | FEMA TECHNICAL BULLETIN 4-93. FEMA REGULATION | | | 60.3(A)(3) IF A PROPOSED BUILDING SITE WILL BE | | | REASONABLY SAFE FROM FLOODING. IF A PROPOSED BUILDING | | | SITE IS IN A FLOOD PRONE AREA, ALL NEW CONSTRUCTION AND | | | SUBSTANTIAL IMPROVEMENTS SHALL? BE CONSTRUCTED WITH | | | MATERIALS RESISTANT TO FLOOD DAMAGE,(III) BE | | | CONSTRUCTED BY METHODS AND PRACTICES THAT MINIMIZE | | | FLOOD DAMAGES, AND (IV) BE CONSTRUCTED WITH | | | ELECTRICAL... EQUIPMENT AND OTHER SERVICES FACILITIES | | | THAT ARE DESIGNED AND / OR LOCATED SO AS TO PREVENT | | | WATER DAMAGE FROM ENTERING OR ACCUMULATING WITHIN THE | | | COMPONENTS DURING CONDITIONS OF FLOODING. | | | TO KEEP THE ELEVATOR CABS FROM HAVING SUBSTANTIAL | | | DAMAGE FROM FLOODWATERS, IS THERE A INTERLOCKING | | | CONTROL OR FLOAT SWITCH THAT WHEN ACTIVATED WILL KEEP | | | THE CAB FROM DESCENDING INTO THE FLOODWATERS. | | | | | | 2) PROVISO: ANY EUROPEAN CAR LIFT SYSTEM WILL NEED TO | | | SUBMIT PRODUCT LISTINGS WHERE THEY HAVE AN NRTL | | | (NATIONALLY RECOGNIZED TESTING LABORATORY) ACCREDITED | | | BY THE US AUTHORITY OCCUPATIONAL SAFETY AND HEALTH | | | ADMINISTRATION AND STAMPED FOR US MARKETS. | | | | | | 3) BUILDING PROVISO: THE PLANS SHOW AT THE ENTRY LEVEL | | | OF THE LOBBY A RECEPTION/ REGISTRATION DESK. PLEASE | | | PROVIDE COMPLIANCE WITH FAIR HOUSING SPECIFICATION OF | | | ANSI 4.31 ALSO SEE REACH RANGES. | | | | | | 4) BUILDING PROVISO: DEFERRED SUBMITTALS : TEST REPORTS | | | SHOWING COMPLIANCE WITH: | | | | | | 4)(1) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND. | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | | | 4)(2) FBC-B 2014 1207.2 AIR-BORNE SOUND. | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | | E 90. | | | | | | 4)(3) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2. | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | | | 5) BUILDING PROVISO: DEFERRED SUBMITTALS: SHEET | | | 431-M4-01 MECHANICAL DETAILS EQUIPMENT SUPPORT CURB | | | DETAIL & THYBAR VIBRATION CURB III DETAIL FOR OAU-1 & | | | 2. PLEASE PROVIDE THE PRODUCT APPROVALS FOR CURB | | | DETAILS. TO BE REVIEWED BY THE STRUCTURAL ENGINEER OF | | | RECORD, AND WITH THEIR SHOP DRAWING STAMP OF APPROVAL. | | | PLEASE NOTE THE STRUCTURAL ANCHOR TO THE BASE OR | | | SUPPORT AS WELL AS THE UNIT TO THE CURB FOR MOMENT OF | | | OVERTURNING, WILL NEED TO BE DESIGNED BY THE STRUCTURAL | | | ENGINEER OR HIS DELEGATE WITH THE STRUCTURAL ENGINEERS | | | APPROVAL BEFORE SUBMITTAL TO THE BUILDING DEPARTMENT | | | FOR REVIEW. | | | FL 61G-15-30.006 (3) THE DELEGATED ENGINEER SHALL | | | FORWARD THE DELEGATED ENGINEERING DOCUMENTS TO THE | | | ENGINEER OF RECORD FOR REVIEW. | | | | | | 6)BUILDING PROVISO: DEFERRED SUBMITTAL FOR | | | ARCHITECTURAL TRIM AND EMBELLISHMENTS METAL FINS ON | | | LEVEL 26. 1407.5 APPROVAL. RESULTS OF APPROVED TESTS OR | | | AN ENGINEERING ANALYSIS SHALL BE SUBMITTED TO THE | | | BUILDING OFFICIAL TO VERIFY COMPLIANCE WITH THE | | | REQUIREMENTS OF CHAPTER 16 FOR WIND LOADS. 1407.6 | | | WEATHER RESISTANCE. IF DELEGATED ENGINEERING THEN THE | | | DOCUMENTS NEED TO BE FORWARDED TO THE ENGINEER OF | | | RECORD FOR REVIEW AND APPROVAL BEFORE SUBMITTING TO THE | | | BUILDING DEPARTMENT. 61G15-30.003. | | | | | | 7) BUILDING PROVISO: DEFERRED SUBMITTAL FOR THE TERRA | | | COTTA WALL CLADDING UNITS. FOR ARCHITECTURAL TRIM AND | | | EMBELLISHMENTS THE TERRA COTTA UNITS WILL NEED TO | | | COMPLY WITH 2010 FBC-B 1407.5 APPROVAL. RESULTS OF | | | APPROVED TESTS OR AN ENGINEERING ANALYSIS SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO VERIFY COMPLIANCE | | | WITH THE REQUIREMENTS OF CHAPTER 16 FOR WIND LOADS. | | | 1407.6 WEATHER RESISTANCE. IF DELEGATED ENGINEERING | | | THEN THE DOCUMENTS NEED TO BE FORWARDED TO THE ENGINEER | | | OF RECORD FOR REVIEW AND APPROVAL BEFORE SUBMITTING TO | | | THE BUILDING DEPARTMENT. 61G15-30.003. | | | | | | 8) BUILDING PROVISO: DEFERRED SUBMITTAL | | | POLYISOCYANURATE BOARD. WITH SINGLE PLY RECOVERY BOARD | | | AND SINGLE PLY PVC ROOFING MEMBRANE ROOFING. PLEASE | | | PROVIDE THE PRODUCT APPROVALS FOR EACH OF THE MEMBERS. | | | FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY ALL ROOFING | | | SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES FOR ROOF | | | ZONE # 1. REVIEW THE PRODUCT APPROVAL LIMITATIONS, IF | | | ENHANCED FASTENING IS ALLOWED FOR ROOF ZONES 2 & 3. | | | FASTENER DENSITIES SHALL BE INCREASED FOR BOTH | | | INSULATION & THE BASE SHEET AS CALCULATED IN COMPLIANCE | | | WITH ROOFING APPLICATION STANDARDS RAS 117. CALCULATION | | | PREPARED, SIGNED AND SEALED BY A FLORIDA REGISTERED | | | PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT. | | | FL 61G-15-30.006 (3) THE DELEGATED ENGINEER SHALL | | | FORWARD THE DELEGATED ENGINEERING DOCUMENTS TO THE | | | ENGINEER OF RECORD FOR REVIEW. | | | | | | 9)BUILDING PROVISO: DEFERRED SUBMITTALS. DETAILS 3 & 4 | | | BOTH SHOW A TILE DECK ABOVE THE ROOFING SYSTEM. THE | | | ROOFING SYSTEM WELL NEED TO PROVIDE PRODUCT APPROVALS | | | FOR WIND AS WELL AS ENGINEERING FOR THE TILE DECK | | | INSTALLATION THEY WILL MEET THE WIND LOADS FOR THE | | | LOCATION ON THE BUILDING.2010 FBC-B COMPONENTS AND | | | CLADDING. 1609.6.4.4.1 COMPONENTS & CLADDING. | | | | | | 10) BUILDING PROVISO: DEFERRED SUBMITTAL. CANOPY | | | SYSTEMS. ADDITIONAL ENGINEERING SHEETS (SHOP DRAWINGS) | | | TO BE SUBMITTED AS A DEFERRED SUBMITTAL. PLEASE ALSO | | | PROVIDE HOW CODE COMPLIANCE WITH 2010 FBC-B 2405.2 | | | ALLOWABLE GLAZING MATERIALS AND LIMITATIONS WILL BE | | | COMPLIED WITH. FL 61G-15-30.006 (3) THE DELEGATED | | | ENGINEER SHALL FORWARD THE DELEGATED ENGINEERING | | | DOCUMENTS TO THE ENGINEER OF RECORD FOR REVIEW. | | | | | | 11) BUILDING PROVISO: 107.3.4.2 DEFERRED SUBMITTALS. | | | 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING | | | | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. ROOF HATCHES. | | | (B) WINDOWS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, CURBS, INTAKE AND | | | EXHAUST FANS ? | | | (E) SHUTTERS | | | (F) SKYLIGHTS | | | (G) PRE-ENGINEERED A/C STANDS | | | 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA | | | RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN WRITING BY | | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2016-08-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-08-29 |
Time |
17:12 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-08-23 |
Time |
08:38 |
Sent To |
|
|
| Notes |
| 2016-08-29 17:12:53 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15111020 | | | ADD: 1100 S. FLAGLER DR. | | | CONT: SUFFOLK CONSTRUCTION CO. | | | TEL: 561-832-1616 | | | E-MAIL: [email protected] / ED HANRATTY | | | | | | 2010 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2ND REVIEW | | | DATE: SAT.- AUG. 26- /2016 | | | ACTION: DENIED | | | | | | NOTE: THIS REVIEW IS GOING TO BE COMPLETED AS A MIXED | | | USE BUILDING,(FEMA REGULATIONS) AND THE REQUIREMENTS AS | | | SUCH. 2010 FBC-B 1612.4 DESIGN & CONSTRUCTION SHALL BE | | | IN ACCORDANCE WITH ASCE 24-05. | | | ASCE 24-05 TABLE 6-1 MINIMUM ELEVATION OF | | | FLOODPROOFING, RELATIVE TO THE BASE FLOOD (BFE) OR | | | DESIGN FLOOD ELEVATION (DFE)- OUTSIDE OF HIGH RISK | | | FLOOD HAZARD AREAS. STRUCTURE CATEGORY- II (FOOTNOTE) | | | C. (C) DRY FLOODPROOFING OF RESIDENTIAL BUILDINGS AND | | | RESIDENTIAL PORTIONS OF MIXED USE BUILDINGS SHALL NOT | | | BE PERMITTED. | | | | | | 1) SHEET 078-A2-0P2 PARKING 2 (LOWER LEVEL): | | | | | | 1A) COMPLIED2010 FBC-B 1612.4 DESIGN & CONSTRUCTION | | | SHALL BE IN ACCORDANCE WITH ASCE 24-05. ASCE 24-05 | | | TABLE 6-1. (FOOTNOTE) C. ( C ) DRY FLOODPROOFING OF | | | RESIDENTIAL BUILDINGS AND RESIDENTIAL PORTIONS OF MIXED | | | USE BUILDINGS SHALL NOT BE PERMITTED. | | | | | | 1B)2ND REQUEST. THE RESPONSE LETTER INDICATES THE | | | ELEVATOR IS A TRACTION ELEVATOR AS IDENTIFIED. THERE IS | | | NO REFERENCE TO THE ELEVATOR BEING A TRACTION ELEVATOR | | | OR A REVISION NUMBER AND BEING CLOUDED, BUBBLED OR A | | | DELTA. | | | ELEVATOR # 9 IS NOT IDENTIFIED ON SHEET 012-LS-P1/ P2. | | | SHEET 176-A5.15 DOES NOT INDICATE IF THIS ELEVATOR IS A | | | HYDRAULIC ELEVATOR? PLEASE IF THE ELEVATOR IS HYDRAULIC | | | SHOW COMPLIANCE WITH 2010 FBC-B 3011. (1-4). IF THIS | | | ELEVATOR IS HYDRAULIC IN WILL THE SUMP PUMP BE TIED | | | INTO THE EMERGENCY ELECTRICAL PANEL TO KEEP DAMAGE TO | | | THE HYDRAULIC SYSTEM AND CAB A MINIMUM. FEMA BULLETIN | | | 4-93. | | | | | | 1C) 2ND REQUEST. THE RESPONSE LETTER INDICATES THE | | | ELEVATOR IS A TRACTION ELEVATOR, WHICH IS MACHINE | | | ROOMLESS ELEVATOR AS IDENTIFIED. THERE IS NO REFERENCE | | | TO THE ELEVATOR BEING A TRACTION ELEVATOR OR A REVISION | | | NUMBER AND BEING CLOUDED, BUBBLED OR A DELTA. | | | ELEVATOR # 9 PLEASE IDENTIFY WHERE THE MACHINE ROOM FOR | | | ELEVATOR # 9 IS LOCATED? PLEASE SHOW COMPLIANCE WITH | | | 2010 FBC-B 3006.4. 1 HOUR FIRE RATING. | | | | | | 1D) 2ND REQUEST. THE RESPONSE INDICATES THE ELEVATOR TO | | | BE A OTIS GEN 2 AND INCLUDES FLOAT SWITCH AND SOFTWARE, | | | IT WOULD APPEAR THERE WOULD BE PRODUCT LITERATURE | | | SUBMITTED, RESEARCHED THE EQUIPMENT SPEC SHEETS 33 | | | SHEETS NOT INCLUDED IN THIS FILE. | | | THE OTHER ISSUE WITH ALL OF THE OTHER ELEVATORS THAT | | | TRAVEL TO THE LOWER P2 PARKING LEVEL DEALS WITH THE | | | FEMA TECHNICAL BULLETIN 4-93. FEMA REGULATION | | | 60.3(A)(3) IF A PROPOSED BUILDING SITE WILL BE | | | REASONABLY SAFE FROM FLOODING. IF A PROPOSED BUILDING | | | SITE IS IN A FLOOD PRONE AREA, ALL NEW CONSTRUCTION AND | | | SUBSTANTIAL IMPROVEMENTS SHALL? BE CONSTRUCTED WITH | | | MATERIALS RESISTANT TO FLOOD DAMAGE,(III) BE | | | CONSTRUCTED BY METHODS AND PRACTICES THAT MINIMIZE | | | FLOOD DAMAGES, AND (IV) BE CONSTRUCTED WITH | | | ELECTRICAL... EQUIPMENT AND OTHER SERVICES FACILITIES | | | THAT ARE DESIGNED AND / OR LOCATED SO AS TO PREVENT | | | WATER DAMAGE FROM ENTERING OR ACCUMULATING WITHIN THE | | | COMPONENTS DURING CONDITIONS OF FLOODING. | | | TO KEEP THE ELEVATOR CABS FROM HAVING SUBSTANTIAL | | | DAMAGE FROM FLOODWATERS, IS THERE A INTERLOCKING | | | CONTROL OR FLOAT SWITCH THAT WHEN ACTIVATED WILL KEEP | | | THE CAB FROM DESCENDING INTO THE FLOODWATERS. | | | THE OTHER QUESTION, IS NORMALLY WITH LOSS OF POWER THE | | | ELEVATOR CABS DESCEND TO THE LOWEST LEVEL , WILL THE | | | INTERLOCK AND OR FLOAT SWITCH ALLOW THE OVERRIDE? | | | DURING TIMES OF FLOOD THIS WILL ENABLE ACCESSIBILITY TO | | | THE LOWER PARKING GARAGE UNLESS THE OCCUPANT TRAVELS | | | DOWN THE STAIRS. | | | | | | 1E) COMPLIED. SMOKE DOORS. DOORS P202/ ELEV. LOBBY 1, | | | DOOR P203/ ELEV. LOBBY 2, DOOR P205 ELEV. LOBBY 3/ DOOR | | | P206/ ELEV. LOBBY #4. , | | | | | | 1F) COMPLIED. FBC-B 905.3. STANDPIPES IN STAIRWELLS. | | | | | | 1G)SEMI-COMPLIED, SHEET 166-A5-01 IDENTIFIES VARIOUS | | | WALLS WITH TAGS: | | | | | | 1G)(1) WALL IDENTIFICATION TAGGED WALLS 70, 71, 73, 74 | | | & 75 ALL SHOW AN ANGLE IRON BRACING SYSTEM ATTACHED TO | | | THE UNDERSIDE OF THE NEXT CONCRETE SLAB AND A NOTE | | | INDICATING A CONTINUOUS FIRE RESISTIVE JOINT SYSTEM. | | | UL LISTING U905 & U906 ARE THE LISTING FOR THE WALL | | | ONLY. PLEASE PROVIDE COMPLIANCE WITH 2010 FBC-B 714.2 | | | AN RATED ASSEMBLY FOR THE DISSIMILAR MATERIALS AT THE | | | JOINT WALL /SLAB JOINT (FIRE ?RESISTANT JOINT SYSTEM). | | | | | | 1ST ROUND COMMENT. THE BUILDING CORES CONTAINING | | | STAIRWELLS 1 & 2 AND 3 & 4 DO NOT HAVE WALL | | | IDENTIFICATION TAGS AS THE WALLS SURROUNDING THE | | | PERIMETER OF THE BUILDING. SHEET 012-A0-31 THE LIFE | | | SAFETY SHEET FOR THE PARKING GARAGES INDICATES FIRE | | | RATED WALLS. 107.2.1.3 ADDITIONAL INFORMATION IS | | | REQUIRED. | | | | | | 1H) SEMI-COMPLIED. THE RESPONSE INDICATES THE VOID | | | SPACE BETWEEN THE INTERSTITIAL FLOOR OF THE FPL VAULT | | | WILL BE FILLED WITH STRUCTURAL GEOFOAM. PLEASE PROVIDE | | | TESTING IN COMPLIANCE WITH 2603.3 SURFACE BURNING | | | CHARACTERISTICS. ASTM E84 OR UL 723. | | | | | | 1ST ROUND OF COMMENTS. THE EAST WALL OF THE FPL VAULT | | | DOES NOT INDICATE A WALL TAG. THE FLOOR ELEVATION IS | | | INDICATED AT ELEVATION 6?-0? THIS WALL WILL STILL BE ON | | | THIS LEVEL. 107.2.1.3 ADDITIONAL INFORMATION IS | | | REQUIRED, WALL NOT IDENTIFIED AS TO TYPE. | | | | | | NEW COMMENTS: | | | 1I) COMMON COMMENT TO ALL FLOORS THE DOOR SCHEDULES | | | FOUND ON SHEETS 331_A8.11 & 332_A8.12 LABEL ALL FIRE | | | RATED DOORS AS B OR C LABEL. PLEASE RATE THEM IN | | | MINUTES AND HOURS AS FBC-B TABLE 715.5. | | | | | | 2) SHEET 079-A2-0P1 (PARKING LEVEL 1 UPPER LEVEL): | | | | | | 2A-D) COMPLIED | | | | | | | | | | | | | | | 2E) SEMI-COMPLIED. PLEASE BE AWARE THIS IS A EUROPEAN | | | SYSTEM THAT PROBABLY DOES NOT HAVE AN UL LISTING, NOR | | | WILL THE 50 HZ 3-PHASE HOOK UP TO THE US STANDARD 60 HZ | | | ELECTRICAL SYSTEM. | | | ELECTRICAL NOTE # 6 INDICATES THE NEED OF A CORNER PIT | | | IN THE FLOOR. ADDITIONAL INFORMATION REQUIRED WHEREAS | | | THE PIT LOCATION AND THE SIZE OF THE PIT. 107.2.1.3. | | | 1ST REVIEW COMMENT. THIS LEVEL SHOWS STACKED PARKING, | | | PLEASE PROVIDE DETAILS FOR THIS TYPE OF LIFT. HOW THE | | | LIFT WILL OPERATE, MANUFACTURERS SPEC, ANCHORAGE FOR | | | LIFT, IS THERE A VALET THAT PUTS THE CARS ON THE LIFT, | | | ETC. 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 2F-G) COMPLIED | | | | | | 3) SHEET 013-A)-32 & 080-A2-01 LEVEL 1 (LOBBY): | | | | | | 3A-D) COMPLIED. | | | | | | 3E) SEMI-COMPLIED. ON THE LOBBY LEVEL THE DOORS TO THE | | | GUEST SUITES LABELED GS01 ARE NOT FOUND IN THE DOOR | | | SCHEDULE PAGE 331_A8-11. | | | | | | 1ST ROUND COMMENT. PLEASE BE AWARE THAT THE DOORS ARE | | | NOT IDENTIFIED ON THIS SHEET, NOR ARE THEY IDENTIFIED | | | ON SHEET 166-A5-01. 107.2.1.3 ADDITIONAL INFORMATION IS | | | REQUIRED. | | | | | | 3F)SEMI-COMPLIED. SHEET 098_A2-51A GUEST SUITE 1 COMMON | | | WALL BATHROOM TO ATRIUM IS LABELED A WALL TYPE 3A. THIS | | | WALL IS A 1 HOUR WALL AND HAS A STC RATING OF 47. | | | PLEASE SEE FBC-B 1207.2 AIR-BORNE SOUND MINIMUM STC OF | | | 50, ASTM E90. | | | 1ST ROUND COMMENTS. PLEASE BE AWARE THAT THE WALL | | | IDENTIFICATION TAGS ON THIS SHEET ARE MISSING AS WELL | | | AS ON SHEET 166-A5-01. 107.2.1.3 ADDITIONAL INFORMATION | | | IS REQUIRED. | | | | | | 3G)2ND REQUEST. PLEASE NOTE IS FOR ALL FLOORS WITH | | | ELEVATOR DOOR OPENINGS. THE PLANS DO NOT INDICATE A | | | FIRE RATED DOOR ON THE ELEVATOR SHAFT. FBC-B 3002.1.1 | | | OPENING PROTECTIVES OPENINGS IN HOISTWAY ENCLOSURES | | | SHALL BE PROTECTED AS REQUIRED IN CHAPTER 7. OPENING | | | PROTECTIVES TABLE 715.5.EXCEPTION THE FLOOR LEVEL | | | DESIGNATED FOR RECALL SHALL REMAIN OPEN DURING PHASE I | | | EMERGENCY RECALL OPERATION. WHAT FLOOR LEVEL WILL BE | | | THE LEVEL DESIGNATED FOR RECALL? | | | 1ST ROUND OF COMMENTS. GUEST ROOM CORRIDOR 102 SHOWS | | | THE WALLS TO BE A MINIMUM OF A 1 HOUR FIRE RATING WITH | | | THE EXCEPTION OF THE ELEVATOR OPENING? PLEASE PROVIDE | | | COMPLIANCE WITH 2010 FBC-B TABLE 1018.1. | | | | | | 3H-K) COMPLIED.. | | | | | | 3L) 2ND REQUEST. THE 1ST LEVEL SHEET 080-A2-01/ | | | 013-A)-32 LIFE SAFETY AND 2ND LEVEL SHEET 081-A2-02/ | | | 014-A0-33 LIFE SAFETY 2ND LEVEL. THESE SHEETS DEPICT A | | | 2 STORY ATRIUM. I?M NOT SPEAKING OF THE STAIRWAY TO | | | BELOW. THE LOBBY FLOOR SHEET 080_A2.01 AND THE SHEET | | | 081_A2.02 LEVEL 2 OF AMENITIES CONSTITUTES AN ATRIUM, | | | WHERE THE AIR COMMUNICATES BETWEEN 2 STORIES. THESE | | | WALLS IN COMMON SHOULD BE FIRE RATED FBC-B 404.6 WITH | | | OPENING PROTECTIVES IN ACCORDANCE WITH TABLE 715.5. | | | | | | 1ST ROUND OF COMMENTS. THE 1ST LEVEL SHEET 080-A2-01/ | | | 013-A)-32 LIFE SAFETY AND 2ND LEVEL SHEET 081-A2-02/ | | | 014-A0-33 LIFE SAFETY 2ND LEVEL. THESE SHEETS DEPICT A | | | 2 STORY ATRIUM. WHAT THE LIFE SAFETY SHEETS FAIL TO | | | PROVIDE IS THE 1 HOUR FIRE BARRIER (2010 FBC-B 404.6) | | | CONSTRUCTED IN ACCORDANCE WITH SECTION 707. THE PLANS | | | DO NOT SHOW A CUT SECTION WHERE ONE OF THE EXCEPTIONS | | | WAS TAKEN. ONE HOUR FIRE RATED WALLS WOULD BE REQUIRED | | | WITH ANY SPACE THAT COMMUNICATED WITH THE ATRIUM AND | | | OPENING PROTECTIVE IN COMPLIANCE WITH 2010 FBC-B TABLE | | | 715.4. SMOKE CONTROL IS NOT REQUIRED SINCE THIS IS A 2 | | | STORY ATRIUM. | | | | | | 3M-O) COMPLIED. 2010 FBC-B 404.8 INTERIOR FINISHES. | | | | | | 3O)(6) SEMI-COMPLIED. SHEET 184A-A5-52, THE DESIGNER OF | | | RECORD HAS PROVIDED THE CHART SHOWING THE EXIT STAIR & | | | RESIDENTIAL UNIT DISTRIBUTION TABLE. THE QUESTION STILL | | | IS HOW WILL THE FIRE FIGHTERS KNOW THIS CHART EXIST, | | | WILL A COPY OF THIS CHART BE POSTED IN THE FIRE COMMAND | | | ROOM OR IN AN OVERALL FIRE MANUAL? | | | | | | 1ST ROUND OF COMMENTS. A CUT SECTION THROUGH THE | | | BUILDING SHOWING WHICH STAIRWELLS SERVICE WHICH SUITES | | | SINCE THE FLOORS WITH 3 SUITES USE STAIRWELLS 2 & 3 SO | | | FIRE FIGHTERS WILL KNOW WHICH STAIRWELLS AND FIREMENS | | | ELEVATORS TO USE FOR FIREFIGHTING AND OR EMERGENCIES. | | | 107.2.1.3 ADDITIONAL INFORMATION REQUIRED. | | | | | | 3P-R) COMPLIED. 2010 FBC-B SECTION 403.3.2 WATER SUPPLY | | | TO REQUIRED FIRE PUMPS | | | | | | 3S) BUILDING PROVISO: THE PLANS SHOW AT THE ENTRY LEVEL | | | OF THE LOBBY A RECEPTION/ REGISTRATION DESK. PLEASE | | | PROVIDE COMPLIANCE WITH FAIR HOUSING SPECIFICATION OF | | | ANSI 4.31 ALSO SEE REACH RANGES. | | | | | | 3T) 2ND REQUEST. THIS COMMENT WILL STAND FOR ALL FLOORS | | | WITH MULTIPLE R2 DWELLING UNITS ON THE SAME FLOOR OR | | | DWELLING UNITS ABOVE OR BELOW THE OCCUPIED UNIT. PLEASE | | | NOTE ALL 3 TEST ARE REQUIRED FOR ANY FLOOR | | | UNDERLAYMENT. IF THERE IS TO BE TILE AND OR MARBLE THE | | | UNDERLAYMENT HAS TO BEEN TESTED ALL 3 TEST, THIS HOLDS | | | TRUE FOR WOOD VENEERS AS WELL. PLEASE KEEP THE 3 TEST | | | CRITERIA TOGETHER, IF THEY ARE POSTED ON THE SAME PLANS | | | SHEET, WE CAN THEN LET THE ACTUAL TEST APPROVALS TO BE | | | A DEFERRED SUBMITTAL AFTER THE ISSUANCE OF THE PERMIT. | | | WE NEED THE CONTRACTOR OR SUB-CONTRACTORS OR VENDORS TO | | | SEE THERE ARE 3 DIFFERENT CRITERIA IN THE SELECTING | | | FLOOR UNDER-LAYMENTS. THANK YOU FOR YOUR HELP IN THIS | | | MATTER. | | | | | | PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH: | | | | | | 3T)(1) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND. | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | | | 3T)(2) FBC-B 2014 1207.2 AIR-BORNE SOUND. | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | | E 90. | | | | | | 3T)(3) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2. | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | | | 3U) COMPLIED. | | | | | | | | | 4) SHEET 014-A0-33/ 082-A2-03: 2ND LEVEL GUEST SUITES. | | | | | | 4A) COMPLIED. GUEST SUITES ARE PURCHASED BY THE CURRENT | | | OWNERS TO BE USED AS A ALTERNATE SLEEPING ROOM. | | | 4B)2ND REQUEST. THE SHAFT WALLS HAVE NOW BEEN | | | IDENTIFIED AS WALL IDENTIFICATION TAGS, 1 & 52. PLEASE | | | NOTE THESE WALLS ARE COMMON WITHIN THE TENANT SPACE AND | | | ONLY HAVE A STC RATING OF 47 NOT THE REQUIRED 50. | | | FBC-B 2010 SECTION 1207.2 AIR-BORNE SOUND. | | | | | | 1ST ROUND OF COMMENTS. THERE IS A DISCREPANCY IN PLANS | | | IT WOULD APPEAR. SHEET 014-A0-33 LEVEL 2 GUEST SUITES | | | IT APPEARS THE MECHANICAL UNIT HP-1IN GUEST SUITES 11 & | | | 12 ARE LOCATED IN A ONE HOUR SHAFT WHEREAS THE UNITS 9 | | | & 10 THE UNITS ARE NOT LOCATED IN A RATED WALL. IT | | | APPEARS IN UNITS 11 & 12 THERE IS A VERTICAL 8X16 INCH | | | EXHAUST DUCT NOT SHOWN IN A SHAFT, MECHANICAL SHEETS | | | INDICATE THAT IN SOME AREA 2 HOUR FLAME BAR IS TO BE | | | INSTALLED. PLEASE PROVIDE DETAILED INFORMATION IN | | | RESPONSE AS TO WHAT AREAS ARE TO BE SHAFTS, HOUR RATING | | | OF SHAFTS, WHERE THE FLAME BAR IS TO BE INSTALLED AND | | | FIRE STOPPING ASSEMBLIES FOR THROUGH PENETRATIONS. THIS | | | COMMENT WILL BE COMMON FOR THE 3 FLOORS OF GUEST | | | SUITES. 2010 FBC-B 708.2.4 /716.6 HORIZONTAL | | | ASSEMBLIES. THIS CONDITION APPEARS ON THE 3RD LEVEL OF | | | GUEST SUITES AS WELL. | | | | | | 4C-D) COMPLIED | | | . | | | | | | 5) SHEET 014-A)-33/ 098-A2-51A2: 2ND LEVEL AMENITIES/ | | | 103-A2.53A THE 3RD LEVEL GUEST SUITES. | | | | | | 5A-B) COMPLIED. | | | | | | 5C)2ND REQUEST. SHEET 098_A2-51A2 &/ 103-A2.53A THE 3RD | | | LEVEL GUEST SUITES IS MISSING BOTH THE WALL & DOOR | | | IDENTIFICATION TAGS. CODE COMPLIANCE CANNOT BE | | | DETERMINED. 107.2.1.3 ADDITIONAL INFORMATION IS | | | REQUIRED. | | | | | | 5D) 2ND REQUEST. SHEET 014-A)-33 IS THE 2ND LEVEL OF | | | THE ATRIUM. THIS SHEETS DEPICTS THE 2ND FLOOR OF THE | | | ATRIUM. WHAT THE LIFE SAFETY SHEETS FAIL TO PROVIDE IS | | | THE 1 HOUR FIRE BARRIER (2010 FBC-B 404.6) CONSTRUCTED | | | IN ACCORDANCE WITH SECTION 707. THE PLANS DO NOT SHOW A | | | CUT SECTION WHERE ONE OF THE EXCEPTIONS WAS TAKEN. ONE | | | HOUR FIRE RATED WALLS WOULD BE REQUIRED WITH ANY SPACE | | | THAT COMMUNICATED WITH THE ATRIUM AND OPENING | | | PROTECTIVE IN COMPLIANCE WITH 2010 FBC-B TABLE 715.4. | | | SMOKE CONTROL IS NOT REQUIRED SINCE THIS IS A 2 STORY | | | ATRIUM. PLEASE NOTE THE 3 LEVELS OF THE R2 GUEST ROOMS | | | TRAVEL THROUGH A 1 HOUR FIRE RATED ACCESS CORRIDOR INTO | | | THE ATRIUM. | | | | | | 5E) COMPLIED | | | | | | 5F) 2ND REQUEST. THIS SHEET INDICATES THE BRIDGE | | | SECTION OF THE 2ND LEVEL IS INDICATED AS A MEZZANINE | | | LOBBY. THE 2ND FLOOR AREA THAT IS OPEN AND COMMUNICATES | | | IS OVER THE 1/3RD OF THE OPEN AREAS ALLOWED BY FBC-B | | | 505.2 EXCEPTION # 2 FOR TYPE I TYPE II BUILDINGS. THIS | | | IS A TRUE 2 STORY ATRIUM, FBC-B 404.6 ENCLOSURES OF | | | ATRIUMS. | | | | | | 5G)2ND REQUEST. SHEET 014-A0-33 POOL DECK STAIR # 6 & 7 | | | SHOW THE USE OF AN AREA OF RESCUE ASSISTANCE. | | | THE RESPONSE INDICATES TWO-WAY COMMUNICATION SYSTEM HAS | | | BEEN PROVIDED, SEE SHEET A0.33. | | | PLEASE SHOW COMPLIANCE WITH ALL ASPECTS OF THE 2003 IBC | | | 1007.6. | | | | | | AREA OF REFUGE. 2003 IBC-B 1007.6 .3 TWO-WAY | | | COMMUNICATION. AREAS OF REFUGE SHALL BE PROVIDED WITH | | | TWO-WAY COMMUNICATION SYSTEM BETWEEN THE AREA OF REFUGE | | | AND A CONTROL POINT. IF THE CENTRAL CONTROL POINT IS | | | NOT CONSTANTLY ATTENDED, THE AREA OF REFUGE SHALL ALSO | | | HAVE CONTROLLED ACCESS TO A PUBLIC TELEPHONE SYSTEM. | | | LOCATION OF THE CENTRAL CONTROL POINT SHALL BE APPROVED | | | BY THE FIRE DEPARTMENT. TWO-WAY COMMUNICATION SYSTEM | | | SHALL INCLUDE BOTH AUDIBLE AND VISIBLE SIGNALS. | | | | | | 1007.6.4 INSTRUCTIONS. IN AREAS OF REFUGE THAT HAVE A | | | TWO-WAY EMERGENCY COMMUNICATIONS SYSTEM, INSTRUCTIONS | | | ON THE USE OF THE AREA UNDER EMERGENCY CONDITIONS SHALL | | | BE POSTED ADJOINING THE COMMUNICATIONS SYSTEM. THE | | | INSTRUCTIONS SHALL INCLUDE ALL OF THE FOLLOWING; | | | 1) DIRECTIONS TO FIND OTHER MEANS OF EGRESS. | | | 2) PERSONS ABLE TO USE THE EXIT STAIRWAY DO SO AS SOON | | | AS POSSIBLE, UNLESS THEY ARE ASSISTING OTHERS. | | | 3) INFORMATION ON THE PLANNED AVAILABILITY OF | | | ASSISTANCE IN THE USE OF STAIRS OR SUPERVISED OPERATION | | | OF ELEVATORS AND HOW TO SUMMON SUCH ASSISTANCE. 4) | | | DIRECTIONS FOR THE USE OF THE EMERGENCY COMMUNICATIONS | | | SYSTEM. | | | | | | 1007.6.5 IDENTIFICATION. EACH DOOR PROVIDING ACCESS TO | | | AN AREA OF REFUGE FROM AN ADJACENT FLOOR AREA SHALL BE | | | IDENTIFIED BY A SIGN COMPLYING WITH ICC A117., STATING | | | AREA OF REFUGE, AND INCLUDING THE INTERNATIONAL SYMBOL | | | OF ACCESSIBILITY. WHERE EXIT SIGN ILLUMINATION IS | | | REQUIRED BY SECTION 1011.2, THE AREA OF REFUGE SIGN | | | SHALL BE ILLUMINATED. ADDITIONALLY, TACTILE SIGNAGE | | | COMPLYING WITH ICC A117.1 SHALL BE LOCATED AT EACH DOOR | | | TO AN AREA OF REFUGE. | | | | | | 1007.7. SIGNAGE. AT EXITS AND ELEVATORS SERVING A | | | REQUIRED ACCESSIBLE SPACE BUT NOT PROVIDING AN APPROVED | | | ACCESSIBLE MEANS OF EGRESS, SIGNAGE SHALL BE INSTALLED | | | INDICATING THE LOCATION OF ACCESSIBLE MEANS OF EGRESS | | | | | | 1ST ROUND COMMENT. SHEET 014-A0-33 POOL DECK STAIR # 6 | | | & 7 SHOW THE USE OF AN AREA OF RESCUE | | | ASSISTANCE. THE 2010 FBC-B 1007.1 ACCESSIBLE MEANS OF | | | EGRESS. ACCESSIBLE MEANS OF EGRESS SHALL BE PROVIDED IN | | | ACCORDANCE WITH THE APPLICABLE SECTIONS OF THE FLORIDA | | | BUILDING CODE, ACCESSIBILITY. | | | 2010 FBC-ACCESSIBILITY CODE. ACCESSIBLE MEANS OF EGRESS | | | . 207.1 GENERAL. MEANS OF EGRESS SHALL COMPLY WITH | | | SECTION 1003.2.13 OF THE INTERNATIONAL BUILDING CODE | | | (2000 EDITION AND 2001 SUPPLEMENT) OR SECTION 1007 OF | | | THE INTERNATIONAL BUILDING CODE (2003 EDITION) | | | (INCORPORATED BY REFERENCE, SEE "REFERENCED STANDARDS" | | | IN CHAPTER 1). | | | PLEASE SHOW FULL COMPLIANCE FOR THE AREA OF REFUGE | | | ASSISTANCE, 2003 IBC-B REQUIREMENTS 1007.6.(1-7) & | | | 1007.8(1-3). | | | | | | | | | START REVIEWS MON. 8/29/16 | | | | | | | | | 5H) COMPLIED. FAIR HOUSING. THE DINING ROOM, BEAUTY | | | PARLOR AND GUEST ROOMS ARE UNDER FAIR HOUSING ACT. FAIR | | | HOUSING IS TO BE APPLIED THEN ONLY ACCESS TO THE POOL | | | DECK WILL BE REQUIRED. | | | | | | 5I) COMPLIED. FAIR HOUSING. AN ACCESSIBLE ROUTE TO THE | | | LOWER POOL DECK AREA. FAIR HOSING ANSI A117.1 4.3 (C) | | | CONNECTING ACCESSIBLE BUILDING OR FACILITY ENTRANCES | | | WITH ACCESSIBLE SPACES AND ELEMENTS WITHIN THE BUILDING | | | OR FACILITY, INCLUDING ADAPTABLE DWELLING UNITS. | | | | | | 5J) COMPLIED. FAIR HOUSING COMPLIANCE FOR THE STEAM | | | ROOMS AND SAUNAS. FAIR HOUSING COMMON USE SPACES AND | | | FACILITIES. WHEN ANSI DOES NOT CONTAIN SPECIFICATIONS | | | FOR SPECIFIC FACILITIES OR FEATURE IN QUESTION RELATED | | | HUMAN FACTORS AND PERFORMANCE SPECIFICATIONS MUST BE | | | USED TO ACHIEVE ACCESSIBILITY. SUCH SPECIFICATIONS | | | INCLUDE, BUT ARE NOT LIMITED TO, 4.2 SPACE ALLOWANCES | | | AND REACH RANGES, 4.3 ACCESSIBLE ROUTE, 4.4 PROTRUDING | | | OBJECTS, 4.5 GROUND & FLOOR SURFACES, AND 4.25 | | | OPERATING MECHANISMS. | | | | | | 5K) 2ND REQUEST, SEMI-COMPLIED, THE RESPONSE INDICATES | | | HOW COMPLIANCE CAN BE OBTAINED. COMPLIANCE WITH COMMENT | | | 5G MUST BE MET FOR COMMENT TO BE COMPLIED WITH. | | | 1ST ROUND COMMENT. SHEET 014-A0-33 THE LOWER POOL DECK | | | IT APPEARS THERE IS ONLY ONE RAMP (NOT MARKED, NOR | | | ELEVATION CHANGES GIVEN) BETWEEN THE POOL DECK AND POOL | | | THERE ARE 116 OCCUPANTS AND WHAT APPEARS TO BE ONLY ONE | | | ACCESSIBLE MEANS OF EGRESS. PLEASE SHOW COMPLIANCE | | | WITH: 2010 FBC-BUILDING CODE 1007.1 ACCESSIBLE MEANS OF | | | EGRESS. ACCESSIBLE MEANS OF EGRESS SHALL BE PROVIDED IN | | | ACCORDANCE WITH THE APPLICABLE SECTIONS OF THE FLORIDA | | | BUILDING CODE, ACCESSIBILITY. | | | 2010 FBC-ACCESSIBILITY CODE SECTION 207.1 MEANS OF | | | EGRESS SHALL COMPLY WITH SECTION 1003.2.13 OF THE | | | INTERNATIONAL BUILDING CODE (2000 EDITION AND 2001 | | | SUPPLEMENT) OR SECTION 1007 OF THE INTERNATIONAL | | | BUILDING CODE (2003 EDITION). | | | 2003 IBC-B 1007.1 WHERE MORE THAN ONE MEANS OF EGRESS | | | IS REQUIRED BY SECTIONS 1014.1 OR 1018.1 FROM ANY | | | ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF THE SPACE | | | SHALL BE SERVED BY NOT LESS THAN TWO MEANS OF EGRESS. | | | | | | | | | | | | 6) SHEETS 015-A0-34 LEVELS 5-10. 11-17 (TIER 1) LEVELS | | | 18-19 TIER 2. / 083-A2-05 LEVEL 5/ 084-A2-06 LEVELS | | | 6-9, 11 TIER 1; | | | 6A) 2ND REQUEST. THIS COMMENT IS A COMMON COMMENT FOR | | | ALL DWELLING UNITS TIER 1 LEVELS 5-9 &11. THE LIFE | | | SAFETY PLAN SHOWS (2) REQUIRED MEANS OF EGRESS PER UNIT | | | OVER 3 STORIES, COMMON PATH OF TRAVEL EXCEEDED WITH ONE | | | MEANS OF EGRESS, BECAUSE THEY ARE OVER THE 125 FEET | | | REQUIRED BY 2010 FBC-B 1014.3 EXCEPTION # 4. | | | | | | 6A)(1) COMPLIED. THE PLANS SHOW THE 1ST COMMON PATH OF | | | TRAVEL EXITING THROUGH THE FRONT ENTRY DOORS THROUGH AN | | | ELEVATOR LOBBY, THE LIFE SAFETY PLANS WILL NEED TO | | | INDICATE IF THE ELEVATOR HOIST WAYS ARE PRESSURIZED TO | | | ALLOW EXITING THROUGH THE ELEVATOR LOBBY. 2010 FBC-B | | | 708.14.1 ELEVATOR LOBBIES. | | | | | | 6A)(2) 2ND REQUEST. THE RESPONSE INDICATES A ISSUE WITH | | | LOCKABLE DOORS ONLY NOT THE CODE SECTION OF NO EGRESS | | | THROUGH STORAGE ROOMS, CLOSETS OR SPACES USED FOR | | | SIMILAR PURPOSES. | | | | | | 1ST ROUND COMMENTS. THE 2ND ISSUE IS THE COMMON PATH OF | | | TRAVEL THROUGH THE LAUNDRY/ STORAGE/ UTILITY ROOM. | | | PLEASE SEE THE 2010 FBC-B SECTION 1014.2.1(4) 4. EGRESS | | | SHALL NOT PASS THROUGH KITCHENS, STORAGE ROOMS, CLOSETS | | | OR SPACES USED FOR SIMILAR PURPOSES. NOTE THE EXCEPTION | | | IS ONLY FOR A KITCHEN AREA SERVING ADJOINING ROOMS | | | CONSTITUTING PART OF THE SAME DWELLING UNIT OR SLEEPING | | | UNIT. | | | | | | 6B) COMPLIED. COMMON COMMENT FOR ALL FLOORS. EXITING | | | CAPACITY ANALYSIS FOR ALL TIERS SHOW A 36 INCH DOORWAY | | | AND THE EXIT CAPACITY AT 180 OCCUPANTS. THIS WOULD MEAN | | | YOU HAVE OFFSET HINGES ON THE EXIT DOORS SO THERE IS A | | | FULL 36 INCHES CLEAR WIDTH FROM THE FACE OF THE DOOR | | | WHEN OPEN AT 90 DEGREES TO THE OPPOSING LATCH SIDE OF | | | THE DOOR AND NOT INCLUDING THE DOOR STOP. SEE 2010 | | | FBC-B 1008.1.1. CLEAR OPENINGS OF DOORWAYS WITH | | | SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF | | | THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES. | | | THE ACTUAL ALLOWABLE MAXIMUM OCCUPANT LOAD IS CLOSER TO | | | 167. | | | | | | 7) 2ND REQUEST. SHEET 016-A0-35 LEVELS 20 & 21 / | | | 090-A2-20 LEVEL 20 REFERS TO SHEET 089- A2.18 FOR UNITS | | | A & B. SHEET 090-A2-20 FOR UNIT C. SAME COMMENTS AND | | | ISSUES AS COMMENTS 6A AND 6B. | | | | | | 8)2ND REQUEST. SHEET 017-A0-36 LIFE SAFETY PLANS FOR | | | LEVEL 22 & 23/ 092-A2-22 & 093-A2-23. SAME COMMENTS AND | | | ISSUES AS COMMENTS 6A AND 6B. | | | | | | 9) PROVISO: SHEET 017-A0-36 LIFE SAFETY PLANS FOR LEVEL | | | 23/ SHEET 093-A2-23. AT OWN RISK!!!!! | | | THE COMMON PATH OF TRAVEL THROUGH THE LAUNDRY/ STORAGE/ | | | UTILITY ROOM. PLEASE SEE THE 2010 FBC-B SECTION | | | 1014.2.1(4) 4. EGRESS SHALL NOT PASS THROUGH KITCHENS, | | | STORAGE ROOMS, CLOSETS OR SPACES USED FOR SIMILAR | | | PURPOSES. NOTE THE EXCEPTION IS ONLY FOR A KITCHEN AREA | | | SERVING ADJOINING ROOMS CONSTITUTING PART OF THE SAME | | | DWELLING UNIT OR SLEEPING UNIT. | | | | | | 10) SHEET 018-A0-37 LEVELS 24 &25/ SHEET 094-A2-24 | | | LEVEL 24 & 095-A2-25. | | | | | | 10A)2ND REQUEST. UNIT PH-24N & PH25N HAS THE SAME | | | ISSUES AS COMMENT 6A)(1) ELEVATOR LOBBY & 6A)(2) EGRESS | | | THROUGH STORAGE/ UTILITY CLOSET / LAUNDRY ROOM. THE | | | 2010 FBC-B SECTION 1014.2.1(4) 4. EGRESS SHALL NOT PASS | | | THROUGH KITCHENS, STORAGE ROOMS, CLOSETS OR SPACES USED | | | FOR SIMILAR PURPOSES. | | | | | | 10B) COMPLIED 2010 FBC-B 708.14.1 ELEVATOR SHAFTS ARE | | | PRESSURIZED. | | | | | | 11) SHEET 019-A)-38 LEVEL 26 MECHANICAL FLOOR - ROOF / | | | 096-A2-26 ARCH. MECHANICAL FLOOR | | | PLAN. A122-A2-76ALEVEL 26 NORTH, 411-M2-26 & 374.S2-26 | | | STRUCTURAL MECHANICAL ROOF FRAMING PLAN. | | | | | | | | | | | | 11A) NEW COMMENT.. SHEET 122-A2-76A ONE WALL THAT | | | ENCLOSES STAIR # 2 IS IDENTIFIED WITH A WALL TAG # 78 | | | THIS WALL DESIGNATION IS NOT FOUND ON SHEET 330-A8-02. | | | 1ST ROUND OF COMMENTS. SHEET 122-A2-76A NONE OF THE | | | ARCHITECTURAL NOR STRUCTURAL SHEETS, PROVIDE A ROOM & | | | WALL IDENTIFICATION TAG FOR THE WALL IN THE UPPER RIGHT | | | CORNER OF THE BUILDING, THE SAME WALL IS ALSO COMMON TO | | | STAIR TOWER #2 AND FIREMANS VESTIBULE 2601. ADDITIONAL | | | INFORMATION IS REQUIRED BOTH THE FIREMANS VESTIBULE | | | (1HR.) AND THE STAIR SHAFT(2 HR.) ARE FIRE RATED | | | PROTECTED. 3007.4.2 & 708.4. | | | | | | 11B-G) COMPLIED. | | | | | | 11H)COMPLIED. SHEET 122-A2-76A LEVEL 26 PLEASE NOTE | | | ROOFTOP AND FLOOR ELEVATION TAGS ARE PROVIDED. | | | | | | 11I) 2ND REQUEST. SEMI-COMPLIED. RESPONSE INDICATES SEE | | | SHEETS A2,56A AND A2.76B. SHEET A2-76B SHOWS THE DOORS | | | WITH IDENTIFICATION TAGS BUR NOT THE WALLS. SHEET | | | A2.56A IS THE FLOOR LEVELS 5-9, 11-17? DO YOU MEAN | | | A2-26 NEITHER THE WALLS NOR DOORS ARE IDENTIFIED? | | | 107.2.1.3. ADDITIONAL INFORMATION IS REQUIRED. | | | 1ST ROUND OF COMMENTS. SHEET 171-A5-06 PLEASE NOTE NONE | | | OF THE WALLS NOR DOORS ARE PROVIDED WITH IDENTIFICATION | | | TAGS, PLANS ARE INCOMPLETE, 107.2.1.3 ADDITIONAL | | | INFORMATION IS REQUIRED. | | | | | | 11J) COMPLIED. SHEET 171-A5-06 AND 096-A2-26 ELEVATOR | | | CONTROL ROOM 3, 4 &6. | | | | | | 11K-N) COMPLIED. | | | | | | 11O) 2ND REQUEST. THE SHEET 123_A2-76B DOES HAVE A NOTE | | | WHERE THE VERTICAL BRACING OCCURS IN THE EXTERIOR | | | CORRIDOR 2604 OUTLINE OF SCREEN WALL & STEEL BRACING | | | ABOVE. THE STRUCTURAL SHEETS 374_S2-26 DOES NOT | | | INDICATE SUCH DETAILS. A DIFFERENT VERSION IS FOUND ON | | | SHEET 375_S2-27 WHERE THE VERTICAL LEG AND BRACING | | | STILL APPEAR TO BE IN THE CORRIDOR. | | | 1ST ROUND COMMENT. SHEET 096-A2-26 THE MECHANICAL | | | EQUIPMENT SCREEN BRACING SYSTEM AS DRAWN HAS LEGS THAT | | | GO INTO THE CORRIDOR 2604 BLOCKING ACCESS, BLOCKING | | | ENTRY TO A EXTERIOR MECHANICAL ROOM 2603 AND ALSO TO | | | ROOM 2606. PLEASE CORRECT THESE AREAS. | | | | | | 12) SEMI- COMPLIED. SHEET 431-M4-01 MECHANICAL DETAILS, | | | DETAIL 20 COOLING TOWER VIBRATION ISOLATOR. | | | RESPONSE INDICATES SEE SHEET 395_A-S5-31 SEE DETAIL # 4 | | | FOR CONCRETE PIER FOR A/C ROOF TOP EQUIPMENT. PLEASE | | | PROVIDE REQUIRED CLEARANCES BELOW RAISED ROOF MOUNTED | | | MECHANICAL UNITS, SEE TABLE 1509.7 | | | FBC-B. TAKE THE MEASUREMENTS FROM THE LOWEST HORIZONTAL | | | FRAMING MEMBER. | | | | | | 1ST ROUND OF COMMENTS. SHEET 431-M4-01 MECHANICAL | | | DETAILS, DETAIL 20 COOLING TOWER VIBRATION ISOLATOR | | | DETAIL TO BE REVIEWED BY THE STRUCTURAL ENGINEER OF | | | RECORD, AND WITH THEIR SHOP DRAWING STAMP OF APPROVAL. | | | PLEASE NOTE THE STRUCTURAL BASE OR SUPPORT WILL NEED TO | | | BE DESIGNED BY THE STRUCTURAL ENGINEER OR HIS DELEGATE | | | WITH THE STRUCTURAL ENGINEERS APPROVAL BEFORE SUBMITTAL | | | TO THE BUILDING DEPARTMENT FOR REVIEW. | | | FL 61G-15-30.006 (3) THE DELEGATED ENGINEER SHALL | | | FORWARD THE DELEGATED ENGINEERING DOCUMENTS TO THE | | | ENGINEER OF RECORD FOR REVIEW. | | | | | | | | | 13) BUILDING PROVISO: DEFERRED SUBMITTALS: SHEET | | | 431-M4-01 MECHANICAL DETAILS EQUIPMENT SUPPORT CURB | | | DETAIL & THYBAR VIBRATION CURB III DETAIL FOR OAU-1 & | | | 2. PLEASE PROVIDE THE PRODUCT APPROVALS FOR CURB | | | DETAILS. TO BE REVIEWED BY THE STRUCTURAL ENGINEER OF | | | RECORD, AND WITH THEIR SHOP DRAWING STAMP OF APPROVAL. | | | PLEASE NOTE THE STRUCTURAL ANCHOR TO THE BASE OR | | | SUPPORT AS WELL AS THE UNIT TO THE CURB FOR MOMENT OF | | | OVERTURNING, WILL NEED TO BE DESIGNED BY THE STRUCTURAL | | | ENGINEER OR HIS DELEGATE WITH THE STRUCTURAL ENGINEERS | | | APPROVAL BEFORE SUBMITTAL TO THE BUILDING DEPARTMENT | | | FOR REVIEW. | | | FL 61G-15-30.006 (3) THE DELEGATED ENGINEER SHALL | | | FORWARD THE DELEGATED ENGINEERING DOCUMENTS TO THE | | | ENGINEER OF RECORD FOR REVIEW. | | | | | | 14) SHEET 131-A3-21. | | | 14A) COMPLIED. | | | | | | 14B) ELEVATORS 2/4 DO NOT CONTINUE THROUGH TO THE ROOF. | | | PLEASE PROVIDE WHERE COMPLIANCE WITH SECTIONS OF THE | | | 2010 FBC-B CAN BE FOUND: | | | | | | 14B)(1) 2ND REQUEST IDENTIFY THE SHAFT THAT GOES TO THE | | | ROOF TOP. 3004.1 VENTS REQUIRED. HOISTWAYS OF ELEVATORS | | | PENETRATING MORE THAN THREE STORIES SHALL BE PROVIDED | | | WITH A MEANS FOR VENTING SMOKE AND HOT GASES TO THE | | | OUTER AIR IN CASE OF FIRE. FOR R1 AND R2 OCCUPANCIES | | | VENTING IS REQUIRED. | | | | | | 14B)(2) 2ND REQUEST IDENTIFY THE SHAFT AND ROOF TOP | | | VENT, SIZE OF THE AREA VENTING. 3004.2 LOCATION OF | | | VENTS. VENTS SHALL BE LOCATED AT THE TOP THE HOISTWAY | | | AND SHALL OPEN EITHER DIRECTLY TO THE OUTER AIR OR | | | THROUGH NONCOMBUSTIBLE DUCTS TO THE OUTER AIR. | | | NONCOMBUSTIBLE DUCTS SHALL BE PERMITTED TO PASS THROUGH | | | THE ELEVATOR MACHINE ROOM, PROVIDED THAT PORTIONS OF | | | THE DUCTS LOCATED OUTSIDE THE HOISTWAY OR MACHINE ROOM | | | ARE ENCLOSED BY CONSTRUCTION HAVING NOT LESS THAN THE | | | FIRE-RESISTANCE RATING REQUIRED FOR THE HOISTWAY. HOLES | | | IN THE MACHINE ROOM FLOORS FOR THE PASSAGE OF ROPES, | | | CABLES OR OTHER MOVING ELEVATOR EQUIPMENT SHALL BE | | | LIMITED AS NOT TO PROVIDE GREATER THAN 2 INCHES (51 MM) | | | OF CLEARANCE ON ALL SIDES. | | | | | | 14)(3) 2ND REQUEST. 3004.3 AREA OF VENTS. EXCEPT AS | | | PROVIDED FOR IN SECTION 3004.3.1, THE AREA OF THE VENTS | | | SHALL NOT BE LESS THAN 31/2 PERCENT OF THE AREA OF THE | | | HOISTWAY NOR LESS THAN 3 SQUARE FEET (0.28 M2) FOR EACH | | | ELEVATOR CAR, AND NOT LESS THAN 31/2 PERCENT NOR LESS | | | THAN 0.5 SQUARE FEET (0.047 M2) FOR EACH DUMBWAITER CAR | | | IN THE HOISTWAY, WHICHEVER IS GREATER. OF THE TOTAL | | | REQUIRED VENT AREA, NOT LESS THAN ONE-THIRD SHALL BE | | | PERMANENTLY OPEN. CLOSED PORTIONS OF THE REQUIRED VENT | | | AREA SHALL CONSIST OF OPENINGS GLAZED WITH ANNEALED | | | GLASS NOT GREATER THAN 1/8 INCH (3.2 MM) IN THICKNESS. | | | | | | | | | 15) SHEET 137-A3-31 DETAILS 1 & 2 & SHEET A0.23 | | | EXTERIOR SYSTEMS. | | | | | | 15A)2ND REQUEST. THE SHEET 137-A3-31 SHOWS VARIOUS | | | AREAS WHERE METAL PANELS ARE GOING TO BE INSTALLED ON | | | THE EXTERIOR OF THE BUILDING. TO DATE NO PLANS HAVE | | | BEEN SUBMITTED FOR COMPLIANCE. THE RESPONSE STATES | | | THESE PANELS ARE METAL PLATE PANELS AND POSSIBLY THE | | | USE OF MCM PANELS. THE SYSTEM IS GOING TO HAVE TO BE | | | BETTER DEFINED AS TO USAGE WEATHER ABILITY, MATERIALS | | | AND ANCHORAGE FOR THE COMPONENT PORTION OF THE | | | BUILDING. | | | AT THE 26TH LEVEL THERE ARE METAL SKINNED ARCHES | | | ARCHITECTURAL ELEMENTS AS WELL AS LEVEL 1 FIN , THAT | | | NEED STRUCTURAL DETAILS THE PAGES REFERENCED S5.31 ARE | | | FOR THE A/C CHILLER SCREEN AND FOR PILLARS FOR THE A/C | | | CHILLER. IS THIS AN ELEMENT THAT YOU WOULD LIKE TO A | | | DEFERRED SUBMITTAL. | | | | | | BOTH INDICATE THE USE OF METAL WALL PANELS, THERE ARE | | | NO CUT SECTIONS INDICATING MORE INFORMATION ON THE | | | PANELS. COMPONENTS AND CLADDING FBC-B, 1609.6.4.4.1 | | | COMPONENTS & CLADDING. PLEASE SEE THE 2010 FBC-B | | | SECTION 1407.3 ARCHITECTURAL TRIM AND EMBELLISHMENTS. | | | MCM USED AS ARCHITECTURAL TRIM OR EMBELLISHMENTS SHALL | | | COMPLY WITH SECTIONS 1407.7 THROUGH 1407.14. | | | 1407.4 STRUCTURAL DESIGN. MCM SYSTEMS SHALL BE DESIGNED | | | AND CONSTRUCTED TO RESIST WIND LOADS AS REQUIRED BY | | | CHAPTER 16 FOR COMPONENTS AND CLADDING. | | | | | | 1407.5 APPROVAL. RESULTS OF APPROVED TESTS OR AN | | | ENGINEERING ANALYSIS SHALL BE SUBMITTED TO THE BUILDING | | | OFFICIAL TO VERIFY COMPLIANCE WITH THE REQUIREMENTS OF | | | CHAPTER 16 FOR WIND LOADS. 1407.6 WEATHER RESISTANCE. | | | | | | 15B) COMPLIED. BALCONY DIVIDER GLASS TO HAVE A ARTIC | | | SNOW PVB INNER CORE, FBC-B 2407 | | | | | | 15C) COMPLIED. | | | | | | 16)2ND REQUEST. SHEETS 108-A2-68A & DETAIL # 2/ | | | 278-A6-85C BALCONY DEMISING GLASS WALL. THE FLOOR PLAN | | | 108-A2-68A DOES SHOW THE USE OF BALCONY DEMISING GLASS | | | WALL AS WELL AS THE ELEVATION SHEET 137-A3-31. THE | | | DETAIL 2 ON SHEET 278-A6-85C APPEAR TO BE FOR INSULATED | | | SPANDREL PANEL BUT NOT FOR THE GLASSED DEMISING WALL IT | | | WOULD APPEAR THIS IS THE WRONG DETAIL. | | | | | | 17) SHEET 157-A4-14 DETAIL 11 SHOWS THE INSTALLATION OF | | | A TERRA COTTA RAIN SCREEN. REFERENCES DETAIL 11/ | | | 157-A4-14 PLEASE PROVIDE COMPLIANCE WITH 2010 FBC-B | | | SECTIONS: | | | | | | 17A) 2ND REQUEST, PLEASE PROVIDE PRODUCT TESTING. | | | 1403.2 WEATHER PROTECTION. | | | | | | 17B) 2ND REQUEST. RESPONSE INDICATES REFER TO | | | STRUCTURAL LOADS REPORT. THE PLANS DO NOT PROVIDE | | | ANCHORAGE, TYPE OF ANCHOR, AT WHAT SPACING AN NO | | | PRODUCT DATA HAS BEEN SUBMITTED FOR THIS SYSTEM. 1403.3 | | | STRUCTURAL. EXTERIOR WALLS, AND THE ASSOCIATED | | | OPENINGS, SHALL BE DESIGNED AND CONSTRUCTED TO RESIST | | | SAFELY THE SUPERIMPOSED LOADS REQUIRED BY CHAPTER 16. | | | | | | 17C) 2ND REQUEST. THE PLANS DO NOT PROVIDE ANCHORAGE, | | | TYPE OF ANCHOR, AT WHAT SPACING AN NO PRODUCT DATA HAS | | | BEEN SUBMITTED FOR THIS SYSTEM. | | | | | | 1405.9 TERRA COTTA. ANCHORED TERRA COTTA OR CERAMIC | | | UNITS NOT LESS THAN 15/8 INCHES (41 MM) THICK SHALL BE | | | ANCHORED DIRECTLY TO MASONRY, CONCRETE OR STUD | | | CONSTRUCTION. TIED TERRA COTTA OR CERAMIC VENEER UNITS | | | SHALL BE NOT LESS THAN 15/8 INCHES (41 MM) THICK WITH | | | PROJECTING DOVETAIL WEBS ON THE BACK SURFACE SPACED | | | APPROXIMATELY 8 INCHES (203 MM) O.C. THE FACING SHALL | | | BE TIED TO THE BACKING WALL WITH CORROSION-RESISTANT | | | METAL ANCHORS OF NOT LESS THAN NO. 8 GAGE WIRE | | | INSTALLED AT THE TOP OF EACH PIECE IN HORIZONTAL BED | | | JOINTS NOT LESS THAN 12 INCHES (305 MM) NOR MORE THAN | | | 18 INCHES (457 MM) O.C.; THESE ANCHORS SHALL BE SECURED | | | TO 1/4-INCH (6.4 MM) CORROSION-RESISTANT PENCIL RODS | | | THAT PASS THROUGH THE VERTICAL ALIGNED LOOP ANCHORS IN | | | THE BACKING WALL. THE VENEER TIES SHALL HAVE SUFFICIENT | | | STRENGTH TO SUPPORT THE FULL WEIGHT OF THE VENEER IN | | | TENSION. THE FACING SHALL BE SET WITH NOT LESS THAN A | | | 2-INCH (51 MM) SPACE FROM THE BACKING WALL AND THE | | | SPACE SHALL BE FILLED SOLIDLY WITH PORTLAND CEMENT | | | GROUT AND PEA GRAVEL. IMMEDIATELY PRIOR TO SETTING, THE | | | BACKING WALL AND THE FACING SHALL BE DRENCHED WITH | | | CLEAN WATER AND SHALL BE DISTINCTLY DAMP WHEN THE GROUT | | | IS POURED. | | | | | | 18) 2ND REQUEST. SHEET 395-S5-33 HAS A CONCEPTUAL | | | DRAWING INDICATING THE TYPE OF TUBE STEEL HSS20X12X | | | ?(LSH) THERE ARE NO DIMENSION FOR ANY OF THE ELEMENTS, | | | ANGLE BETWEEN FRAMING MEMBERS, WELDS, TYPE OF | | | ATTACHMENT TO DECKS BOTH TOP AND BOTTOM. 197.2.1.3 | | | ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 1ST REVIEW. SHEETS 160-A4.15 PODIUM METAL FIN, | | | 161-A4.16 PODIUM METAL FIN, THE DETAIL # 2 ON SHEET 160 | | | INDICATES A HSS TUBE POST, REFER TO STRUCTURAL SHEETS. | | | THE STRUCTURAL SHEETS DO NOT PROVIDE DETAILS OF THIS | | | STRUCTURAL TUBE. SHEET 395-S5-33 HAS A CONCEPTUAL | | | DRAWING INDICATING THE TYPE OF TUBE STEEL HSS20X12X | | | ?(LSH) THERE ARE NO DIMENSION FOR ANY OF THE ELEMENTS, | | | ANGLE BETWEEN FRAMING MEMBERS, WELDS, TYPE OF | | | ATTACHMENT TO DECKS BOTH TOP AND BOTTOM. 197.2.1.3 | | | ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 19) SHEET 162-A4-31 ROOF DETAILS: | | | 19A) DETAILS 1 & 2 SHOW THE USE OF POLYISOCYANURATE | | | BOARD. WITH SINGLE PLY RECOVERY BOARD AND SINGLE PLY | | | PVC ROOFING MEMBRANE ROOFING. PLEASE PROVIDE THE | | | PRODUCT APPROVALS FOR EACH OF THE MEMBERS. FOR ALL | | | ROOFING PRODUCTS PLEASE IDENTIFY ALL ROOFING | | | SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES FOR ROOF | | | ZONE # 1. REVIEW THE PRODUCT APPROVAL LIMITATIONS, IF | | | ENHANCED FASTENING IS ALLOWED FOR ROOF ZONES 2 & 3. | | | FASTENER DENSITIES SHALL BE INCREASED FOR BOTH | | | INSULATION & THE BASE SHEET AS CALCULATED IN COMPLIANCE | | | WITH ROOFING APPLICATION STANDARDS RAS 117. CALCULATION | | | PREPARED, SIGNED AND SEALED BY A FLORIDA REGISTERED | | | PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT. | | | FL 61G-15-30.006 (3) THE DELEGATED ENGINEER SHALL | | | FORWARD THE DELEGATED ENGINEERING DOCUMENTS TO THE | | | ENGINEER OF RECORD FOR REVIEW. | | | | | | 19B) DEFERRED SUBMITTALS. DETAILS 3 & 4 BOTH SHOW A | | | TILE DECK ABOVE THE ROOFING SYSTEM. THE ROOFING SYSTEM | | | WELL NEED TO PROVIDE PRODUCT APPROVALS FOR WIND AS WELL | | | AS ENGINEERING FOR THE TILE DECK INSTALLATION THEY WILL | | | MEET THE WIND LOADS FOR THE LOCATION ON THE | | | BUILDING.2010 FBC-B COMPONENTS AND CLADDING. | | | 1609.6.4.4.1 COMPONENTS & CLADDING. | | | | | | 20) BUILDING PROVISO: SHEETS 164-A4-41 AND 165-A4-41A | | | S2.02 PROVIDE A BASIC DESIGN FOR THE CANOPY SYSTEMS. | | | ADDITIONAL ENGINEERING SHEETS (SHOP DRAWINGS) TO BE | | | SUBMITTED AS A DEFERRED SUBMITTAL. PLEASE ALSO PROVIDE | | | HOW CODE COMPLIANCE WITH 2010 FBC-B 2405.2 ALLOWABLE | | | GLAZING MATERIALS AND LIMITATIONS WILL BE COMPLIED | | | WITH. FL 61G-15-30.006 (3) THE DELEGATED ENGINEER SHALL | | | FORWARD THE DELEGATED ENGINEERING DOCUMENTS TO THE | | | ENGINEER OF RECORD FOR REVIEW. | | | | | | 21) BUILDING PROVISO: 107.3.4.2 DEFERRED SUBMITTALS. | | | 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING | | | | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. ROOF HATCHES. | | | (B) WINDOWS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, CURBS, INTAKE AND | | | EXHAUST FANS ? | | | (E) SHUTTERS | | | (F) SKYLIGHTS | | | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C | | | STANDS | | | 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA | | | RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN WRITING BY | | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | | | | 22) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2016-02-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-02-01 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-01-27 |
Time |
05:58 |
Sent To |
|
|
| Notes |
| 2016-02-01 10:44:07 | BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 15111020 | | | ADD: 1100 S. FLAGLER DR. | | | CONT: SUFFOLK CONSTRUCTION CO. | | | TEL: 561-832-1616 | | | E-MAIL: [email protected] / ED HANRATTY | | | | | | 2010 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | | | | 1ST REVIEW | | | DATE: MON. FEB. 01/2016 | | | ACTION: DENIED | | | | | | NOTE: THIS REVIEW IS GOING TO BE COMPLETED AS A MIXED | | | USE BUILDING, AND THE REQUIREMENTS FOR THE FOUNDATION | | | PERMIT WILL BE MET AND THE ISSUANCE OF THE FOUNDATION | | | PERMIT WILL BE FORTH COMING. PLEASE NOTE SOME COMMENTS | | | MAY APPEAR AS WAS IN THE FOUNDATION PERMIT. | | | 2010 FBC-B 1612.4 DESIGN & CONSTRUCTION SHALL BE IN | | | ACCORDANCE WITH ASCE 24-05. | | | ASCE 24-05 TABLE 6-1 MINIMUM ELEVATION OF | | | FLOODPROOFING, RELATIVE TO THE BASE FLOOD (BFE) OR | | | DESIGN FLOOD ELEVATION (DFE)- OUTSIDE OF HIGH RISK | | | FLOOD HAZARD AREAS. STRUCTURE CATEGORY- II (FOOTNOTE) | | | C. (C) DRY FLOODPROOFING OF RESIDENTIAL BUILDINGS AND | | | RESIDENTIAL PORTIONS OF MIXED USE BUILDINGS SHALL NOT | | | BE PERMITTED. | | | | | | 1) SHEET 078-A2-0P2 PARKING 2 (LOWER LEVEL) : | | | 1A) PLEASE SEE NOTE ABOVE THE LOWER LEVEL OF THE | | | PARKING GARAGE CANNOT BE USED FOR THE PARKING OF | | | RESIDENTIAL VEHICLES OR STORAGE FOR THE RESIDENTS OF | | | THE BUILDING. THE PLANS INDICATE 9 PRIVATE PARKING | | | GARAGES AND VARIOUS AREAS THROUGHOUT THE LOWER PARKING | | | AREA THAT INDICATE RESIDENT STORAGE. | | | 2010 FBC-B 1612.4 DESIGN & CONSTRUCTION SHALL BE IN | | | ACCORDANCE WITH ASCE 24-05. ASCE 24-05 TABLE 6-1. | | | (FOOTNOTE) C. ( C ) DRY FLOODPROOFING OF RESIDENTIAL | | | BUILDINGS AND RESIDENTIAL PORTIONS OF MIXED USE | | | BUILDINGS SHALL NOT BE PERMITTED. | | | | | | 1B) ELEVATOR # 9 IS NOT IDENTIFIED ON SHEET 012-LS-P1/ | | | P2. SHEET 176-A5.15 DOES NOT INDICATE IF THIS ELEVATOR | | | IS A HYDRAULIC ELEVATOR? PLEASE IF THE ELEVATOR IS | | | HYDRAULIC SHOW COMPLIANCE WITH 2010 FBC-B 3011. (1-4). | | | IF THIS ELEVATOR IS HYDRAULIC IN WILL THE SUMP PUMP BE | | | TIED INTO THE EMERGENCY ELECTRICAL PANEL TO KEEP DAMAGE | | | TO THE HYDRAULIC SYSTEM AND CAB A MINIMUM. FEMA | | | BULLETIN 4-93. | | | | | | 1C) ELEVATOR # 9 PLEASE IDENTIFY WHERE THE MACHINE ROOM | | | FOR ELEVATOR # 9 IS LOCATED? PLEASE SHOW COMPLIANCE | | | WITH 2010 FBC-B 3006.4. 1 HOUR FIRE RATING. | | | | | | 1D) THE OTHER ISSUE WITH ALL OF THE OTHER ELEVATORS | | | THAT TRAVEL TO THE LOWER P2 PARKING LEVEL DEALS WITH | | | THE FEMA TECHNICAL BULLETIN 4-93. FEMA REGULATION | | | 60.3(A)(3) IF A PROPOSED BUILDING SITE WILL BE | | | REASONABLY SAFE FROM FLOODING. IF A PROPOSED BUILDING | | | SITE IS IN A FLOOD PRONE AREA, ALL NEW CONSTRUCTION AND | | | SUBSTANTIAL IMPROVEMENTS SHALL? BE CONSTRUCTED WITH | | | MATERIALS RESISTANT TO FLOOD DAMAGE,(III) BE | | | CONSTRUCTED BY METHODS AND PRACTICES THAT MINIMIZE | | | FLOOD DAMAGES, AND (IV) BE CONSTRUCTED WITH | | | ELECTRICAL... EQUIPMENT AND OTHER SERVICES FACILITIES | | | THAT ARE DESIGNED AND / OR LOCATED SO AS TO PREVENT | | | WATER DAMAGE FROM ENTERING OR ACCUMULATING WITHIN THE | | | COMPONENTS DURING CONDITIONS OF FLOODING. | | | TO KEEP THE ELEVATOR CABS FROM HAVING SUBSTANTIAL | | | DAMAGE FROM FLOODWATERS, IS THERE A INTERLOCKING | | | CONTROL OR FLOAT SWITCH THAT WHEN ACTIVATED WILL KEEP | | | THE CAB FROM DESCENDING INTO THE FLOODWATERS. | | | THE OTHER QUESTION, IS NORMALLY WITH LOSS OF POWER THE | | | ELEVATOR CABS DESCEND TO THE LOWEST LEVEL , WILL THE | | | INTERLOCK AND OR FLOAT SWITCH ALLOW THE OVERRIDE? | | | DURING TIMES OF FLOOD THIS WILL ENABLE ACCESSIBILITY TO | | | THE LOWER PARKING GARAGE UNLESS THE OCCUPANT TRAVELS | | | DOWN THE STAIRS. | | | | | | 1E) DOORS P202/ ELEV. LOBBY 1, DOOR P203/ ELEV. LOBBY | | | 2, DOOR P205 ELEV. LOBBY 3/ DOOR P206/ ELEV. LOBBY #4, | | | ON THE DOOR SCHEDULE SHEET 332-A8-11 DO NOT INDICATE A | | | FIRE RATING, PLEASE SEE 2010 FBC-B 708.14.1 REQUIRING A | | | FIRE PARTITION AS IN 709 OR ONE OF THE EXCEPTIONS. | | | | | | 1F) STAIR # 1 IS MISSING THE STAND PIPE IN THE | | | STAIRWELL. 2010 FBC-B 905.3. REQUIRED INSTALLATION. | | | ALSO NOT SHOWN ON 177-A5-21. | | | | | | 1G) THE BUILDING CORES CONTAINING STAIRWELLS 1 & 2 AND | | | 3 & 4 DO NOT HAVE WALL IDENTIFICATION TAGS AS THE WALLS | | | SURROUNDING THE PERIMETER OF THE BUILDING. SHEET | | | 012-A0-31 THE LIFE SAFETY SHEET FOR THE PARKING GARAGES | | | INDICATES FIRE RATED WALLS. 107.2.1.3 ADDITIONAL | | | INFORMATION IS REQUIRED. | | | | | | 1H) THE EAST WALL OF THE FPL VAULT DOES NOT INDICATE A | | | WALL TAG. THE FLOOR ELEVATION IS INDICATED AT ELEVATION | | | 6?-0? THIS WALL WILL STILL BE ON THIS LEVEL. 107.2.1.3 | | | ADDITIONAL INFORMATION IS REQUIRED, WALL NOT IDENTIFIED | | | AS TO TYPE. | | | | | | 2) SHEET 079-A2-0P1 (PARKING LEVEL 1 UPPER LEVEL): | | | 2A) ROOM # P123, THE FPL VAULT INDICATES AN EXTERIOR | | | PAIR OF DOORS P123B AS THE ONLY DOORS. THE DOOR | | | SCHEDULE INDICATES FOR THIS ROOM DOORS P123A AND P123B | | | BOTH SETS OF DOORS ARE PAIRS OF DOORS. WHERE IS THE 2ND | | | SET OF DOORS? 107.2.1.3 ADDITIONAL INFORMATION IS | | | REQUIRED. MISSING DOOR LOCATION. | | | | | | 2B) THE FPL VAULT DOORS SHOW ON THE HARDWARE SCHEDULE, | | | HARDWARE TYPE 41. THERE ARE NO SHEETS IN THE INDEX THAT | | | SHOW A HARDWARE SCHEDULE. PLEASE NOTE IF THE HARDWARE | | | SCHEDULE IS IN A SPEC BOOK, WE DO NOT REVIEW SPEC | | | BOOKS. PLEASE PROVIDE THE HARDWARE SCHEDULE. 2010 FBC-B | | | 1008.1.10 PANIC AND FIRE EXIT HARDWARE. ELECTRICAL | | | ROOMS WITH EQUIPMENT RATED 1,200 AMPERES OR MORE AND | | | OVER 6 FEET (1829 MM) WIDE THAT CONTAIN OVERCURRENT | | | DEVICES, SWITCHING DEVICES OR CONTROL DEVICES WITH EXIT | | | OR EXIT ACCESS DOORS SHALL BE EQUIPPED WITH PANIC | | | HARDWARE OR FIRE EXIT HARDWARE. THE DOORS SHALL SWING | | | IN THE DIRECTION OF EGRESS TRAVEL. | | | | | | 2C) THE DOOR SCHEDULE SHEET 331-A8-11 DOOR # UNDER THE | | | HEADING OF NOTES INDICATES EXTERIOR DOOR WITH FLOOD | | | BARRIER. PLEASE PROVIDE WHAT STEPS ARE GOING TO TAKE | | | PLACE FOR A FLOOD BARRIER FOR THIS DOOR. THIS CONDITION | | | WILL NEED TO BE PART OF THE FLOOD EMERGENCY OPERATION | | | PLAN, INSPECTION AND MAINTENANCE PLAN AND MINIMUM | | | ENGINEERING CONSIDERATIONS (2) SEE FEMA?S TECHNICAL | | | BULLETIN 3-93 NON-RESIDENTIAL FLOODPROOFING- | | | REQUIREMENTS AND CERTIFICATION. | | | | | | 2D) THE MAIN ELECTRIC ROOM P124 DOES INDICATE 2 DOORS | | | BUT ONE DOOR HAS DIFFERENT HARDWARE THAN THE FPL VAULT | | | AND THE OTHER DOOR OF THE ELECTRICAL ROOM. HARDWARE | | | TYPE 44 THE OTHER DOORS HAVE A HARDWARE TYPE 41. THERE | | | IS NO HARDWARE SCHEDULE TO IDENTIFY THE TYPES OF | | | HARDWARE. PLEASE PROVIDE CODE COMPLIANCE WITH 2010 | | | FBC-B B 1008.1.10 PANIC AND FIRE EXIT HARDWARE. | | | ELECTRICAL ROOMS WITH EQUIPMENT RATED 1,200 AMPERES OR | | | MORE AND OVER 6 FEET (1829 MM) WIDE THAT CONTAIN | | | OVERCURRENT DEVICES, SWITCHING DEVICES OR CONTROL | | | DEVICES WITH EXIT OR EXIT ACCESS DOORS SHALL BE | | | EQUIPPED WITH PANIC HARDWARE OR FIRE EXIT HARDWARE. THE | | | DOORS SHALL SWING IN THE DIRECTION OF EGRESS TRAVEL. | | | | | | 2E) THIS LEVEL SHOWS STACKED PARKING, PLEASE PROVIDE | | | DETAILS FOR THIS TYPE OF LIFT. HOW THE LIFT WILL | | | OPERATE, MANUFACTURERS SPEC, ANCHORAGE FOR LIFT, IS | | | THERE A VALET THAT PUTS THE CARS ON THE LIFT, ETC? | | | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 2F) THE SOUTH CORE PLAN SHOWS A WALL IDENTIFICATION TAG | | | # 76 AS A 6 INCH CMU NON-BEARING WALL WITH A 2 HOUR | | | FIRE RATING. PLEASE SHOW HOW A 2 HOUR FIRE RESISTANCE | | | RATING WILL BE ACHIEVED. 2010 FBC-B TABLE 721.3.2. | | | PLEASE PROVIDE FROM THE BLOCK MANUFACTURERS EQUIVALENT | | | THICKNESS IN COMPLIANCE. | | | | | | 2G) TRASH ROOM P114 IS MISSING THE DOOR IDENTIFICATION | | | TAG AND OPENING PROTECTIVE FIRE RATING. 2010 FBC-B | | | TABLE 715.4. | | | | | | 3) SHEET 013-A)-32 & 080-A2-01 LEVEL 1 (LOBBY) : | | | 3A) STAIR # 1 VERSUS THE FIRE EXIT CORRIDOR. THE STAIR | | | EXIT CORRIDOR IS ACTUALLY AN EXIT PASSAGE WAY, WHICH | | | REQUIRES THE EXIT ENCLOSURE TO BE SEPARATED FROM THE | | | EXIT PASSAGEWAY BY A FIRE BARRIER. A FIRE DOOR ASSEMBLY | | | COMPLYING WITH SECTION 715.4/ TABLE 715.4 (1 ? HR. | | | PROTECTIVE) SHALL BE INSTALLED IN THE FIRE BARRIER TO | | | PROVIDE A MEANS OF EGRESS FROM THE EXIT ENCLOSURE TO | | | THE EXIT PASSAGE WAY. SEE 2010 FBC-B 1022.1. | | | | | | 3B) PLEASE SEE THE STAIR # 1 WITH THE NEW 1 ? HR. | | | OPENING PROTECTIVE ON THE VERTICAL EXIT SEPARATING THE | | | VERTICAL EXIT FROM THE EXIT PASSAGEWAY WILL NEED THE | | | PLANS REVISED BECAUSE THE 2 DOORWAYS THAT SWING INTO | | | THE EXIT PASSAGE WAY WILL CREATE A BOTTLENECK AND BLOCK | | | ONE OF THE DOORS THAT SWING INTO THE EXIT PASSAGEWAY. | | | 2010 FBC-B 1003.3 PROTRUDING OBJECTS. | | | | | | 3C) PLEASE BE AWARE OF FBC-B 1023.6. PENETRATIONS. | | | PENETRATIONS INTO AND OPENINGS THROUGH AN EXIT | | | PASSAGEWAY ARE PROHIBITED EXCEPT FOR REQUIRED EXIT | | | DOORS, EQUIPMENT AND DUCTWORK NECESSARY FOR INDEPENDENT | | | PRESSURIZATION, SPRINKLER PIPING, STANDPIPES, | | | ELECTRICAL RACEWAY FOR FIRE DEPARTMENT COMMUNICATION | | | AND ELECTRICAL RACEWAY SERVING THE EXIT PASSAGEWAY AND | | | TERMINATING AT A STEEL BOX NOT EXCEEDING 16 SQUARE | | | INCHES. | | | | | | 3D) STAIR # 1 IS MISSING THE REQUIRED STANDPIPE 2010 | | | FBC-B 905.3.1. THIS STATEMENT WILL STAND FOR ALL | | | FLOORS. | | | | | | 3E) PLEASE BE AWARE THAT THE DOORS ARE NOT IDENTIFIED | | | ON THIS SHEET, NOR ARE THEY IDENTIFIED ON SHEET | | | 166-A5-01. 107.2.1.3 ADDITIONAL INFORMATION IS | | | REQUIRED. | | | | | | 3F) PLEASE BE AWARE THAT THE WALL IDENTIFICATION TAGS | | | ON THIS SHEET ARE MISSING AS WELL AS ON SHEET | | | 166-A5-01. 107.2.1.3 ADDITIONAL INFORMATION IS | | | REQUIRED. | | | | | | 3G) GUEST ROOM CORRIDOR 102 SHOWS THE WALLS TO BE A | | | MINIMUM OF A 1 HOUR FIRE RATING WITH THE EXCEPTION OF | | | THE ELEVATOR OPENING? PLEASE PROVIDE COMPLIANCE WITH | | | 2010 FBC-B TABLE 1018.1. | | | | | | 3H) THE CORRIDOR 102 FOR THE GUEST SUITES REQUIRES THE | | | 1 HOUR RATING, THE 2010 FBC-B 1018.6 CORRIDOR | | | CONTINUITY. FIRE-RESISTANCE-RATED CORRIDORS SHALL BE | | | CONTINUOUS FROM THE POINT OF ENTRY TO AN EXIT, AND | | | SHALL NOT BE INTERRUPTED BY INTERVENING ROOMS. | | | EXCEPTION: FOYERS, LOBBIES OR RECEPTION ROOMS | | | CONSTRUCTED AS REQUIRED FOR CORRIDORS SHALL NOT BE | | | CONSTRUED AS INTERVENING ROOMS. | | | PLEASE NOTE THE 1 HOUR FIRE RATING WAS NOT CONTINUED TO | | | THE EXIT DOORWAY, LOBBY DOORS. | | | | | | 3I) STAIR TOWER # 4 IS MISSING THE REQUIRED FIRE DOOR | | | BETWEEN THE VERTICAL EXIT AND THE EXIT PASSAGE WAY. | | | 2010 FBC-B. A FIRE DOOR ASSEMBLY COMPLYING WITH SECTION | | | 715.4/ TABLE 715.4 (1 ? HR. PROTECTIVE) SHALL BE | | | INSTALLED IN THE FIRE BARRIER TO PROVIDE A MEANS OF | | | EGRESS FROM THE EXIT ENCLOSURE TO THE EXIT PASSAGE WAY. | | | SEE 2010 FBC-B 1022.1. | | | | | | 3J) ROOM 143 THERE IS WHAT APPEARS TO BE A 2 HOUR RATED | | | SHAFT ENCLOSURE NEXT TO A COLUMN WITH ONE END OF THE | | | SHAT ENCLOSURE NOT RATED. 2010 FBC-B 708.4. 2 HOUR | | | SHAFT ENCLOSURE REQUIRED. | | | | | | 3K) PLEASE REVIEW THE (2) PAIR OF DOUBLE DOORS IN | | | CORRIDOR 114 AND THE BEAUTY SALON 143. THERE IS LESS | | | THAN 4 FEET BETWEEN DOORS. FAIR HOUSING ANSI A117-1998 | | | SECTION. 404.2.6 DOORS IN SERIES. | | | | | | 3L) THE 1ST LEVEL SHEET 080-A2-01/ 013-A)-32 LIFE | | | SAFETY AND 2ND LEVEL SHEET 081-A2-02/ 014-A0-33 LIFE | | | SAFETY 2ND LEVEL. THESE SHEETS DEPICT A 2 STORY ATRIUM. | | | WHAT THE LIFE SAFETY SHEETS FAIL TO PROVIDE IS THE 1 | | | HOUR FIRE BARRIER (2010 FBC-B 404.6) CONSTRUCTED IN | | | ACCORDANCE WITH SECTION 707. THE PLANS DO NOT SHOW A | | | CUT SECTION WHERE ONE OF THE EXCEPTIONS WAS TAKEN. ONE | | | HOUR FIRE RATED WALLS WOULD BE REQUIRED WITH ANY SPACE | | | THAT COMMUNICATED WITH THE ATRIUM AND OPENING | | | PROTECTIVE IN COMPLIANCE WITH 2010 FBC-B TABLE 715.4. | | | SMOKE CONTROL IS NOT REQUIRED SINCE THIS IS A 2 STORY | | | ATRIUM. | | | | | | 3M) ATRIUM. PLEASE SHOW HOW CODE COMPLIANCE WITH | | | SECTION OF THE 2010 FBC-B 404.8 INTERIOR FINISHES. THE | | | INTERIOR FINISHES OF WALLS AND CEILINGS OF THE ATRIUM | | | SHALL NOT BE LESS THAN CLASS B WITH NO REDUCTIONS IN | | | CLASS FOR SPRINKLER PROTECTION. | | | | | | 3N) BOTH ELEVATOR 7 & 9 BOTH ARE MISSING THE ELEVATOR | | | LOBBY OR ONE OF THE EXCEPTIONS FOR ELEVATORS IN A | | | HIGH-RISE BUILDING. 2010 FBC-B 708.14.1 AND OR | | | EXCEPTIONS. PLEASE REVIEW BOAF (BUILDING OFFICIALS | | | INFORMAL INTERPRETATION 3762. | | | DATE: TUE JUN 28 2005 | | | REPORT #: 3762 | | | CODE: BUILDING | | | SECTION: 412.6 | | | QUESTION: | | | IS IT THE INTENT OF SECTION 412.6 TO REQUIRE THE | | | ELEVATOR LOBBIES FOR ALL ELEVATORS WITHIN A HIGH-RISE | | | BUILDING? ARE ELEVATORS THAT DO NOT SERVE THE HIGH-RISE | | | PORTION OF THE BUILDING EXEMPT FROM THE ELEVATOR | | | LOBBY REQUIREMENTS? | | | ANSWER: | | | YES. ELEVATOR LOBBIES ARE REQUIRED FOR LOW-RISE | | | PORTIONS OF HIGH-RISE BUILDINGS. ELEVATOR LOBBIES SERVE | | | AS | | | A STAGING AREA FOR EMERGENCY PERSONNEL DURING A FIRE | | | EMERGENCY AND A COMPARATIVELY SMOKE-FREE SPACE | | | FOR HANDLING OCCUPANTS NEEDING SPECIAL ASSISTANCE WITH | | | EVACUATION. | | | COMMENTARY: | | | IT IS THE INTENT OF SECTION 412.6 TO, AMONG OTHER | | | THINGS, (1)PREVENT MIGRATION OF HEAT AND HARMFUL | | | PRODUCTS OF COMBUSTION THROUGH THE ELEVATOR HOISTWAY TO | | | OTHER FLOORS IN HIGH-RISE BUILDINGS (2)PROVIDE | | | PROTECTION FOR FIRE FIGHTER OPERATIONS IN THE EVENT THE | | | ELEVATORS ARE USED FOR EMERGENCY RESPONSE IN A | | | HIGH-RISE STRUCTURE (3)INHIBIT POTENTIAL EFFECTS OF THE | | | ELEVATOR HOISTWAY ON THE PERFORMANCE OF HIGH-RISE SMOKE | | | CONTROL SYSTEMS AND (4) ENHANCE LIFE SAFETY IN EXIT | | | ACCESS CORRIDORS THAT REQUIRE OCCUPANTS TO TRAVERSE AN | | | ELEVATOR LOBBY THAT SERVES AS PART OF THE EXIT ACCESS | | | IN A HIGH-RISE BUILDING. | | | NOTICE: | | | THE BUILDING OFFICIALS ASSOCIATION OF FLORIDA, IN | | | COOPERATION WITH THE FLORIDA BUILDING COMMISSION, THE | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS, ICC, AND | | | INDUSTRY AND PROFESSIONAL EXPERTS OFFER THIS | | | INTERPRETATION OF THE FLORIDA BUILDING CODE IN THE | | | INTEREST OF CONSISTENCY IN THEIR APPLICATION STATEWIDE. | | | THIS INTERPRETATION IS INFORMAL, NON-BINDING AND | | | SUBJECT TO ACCEPTANCE AND APPROVAL BY THE LOCAL | | | BUILDING OFFICIAL. | | | | | | 3O) THE FIRE COMMAND CENTER MEETS THE 200 SQUARE FOOT | | | REQUIREMENT BUT PLEASE PROVIDE A DETAILED LAYOUT OF THE | | | FIRE COMMAND CENTER TO BE APPROVED BY FIRE PRIOR TO | | | INSTALLATION. 2010 FBC-B 911.1.4. | | | PLEASE REVIEW FBC-B 911.1.5 FOR REQUIRED FEATURES. | | | | | | 3O)(1) PLEASE SHOW COMPLIANCE WITH 2010 FBC-B: 403.4.3 | | | EMERGENCY VOICE/ALARM COMMUNICATION SYSTEM. | | | | | | 3O)(2) PLEASE SHOW COMPLIANCE WITH 2010 FBC-B: 403.4.4 | | | EMERGENCY RESPONDER RADIO COVERAGE. AN EMERGENCY | | | VOICE/ALARM COMMUNICATION SYSTEM SHALL BE PROVIDED IN | | | ACCORDANCE WITH SECTION 907.5.2.2. | | | EMERGENCY RESPONDER RADIO COVERAGE SHALL BE PROVIDED IN | | | ACCORDANCE WITH THE FLORIDA FIRE PREVENTION CODE. | | | SECTION 907.5.2.2. | | | | | | 3O)(3) PLEASE SHOW COMPLIANCE WITH 2010: 403.5.3 | | | STAIRWAY DOOR OPERATION. STAIRWAY DOORS OTHER THAN THE | | | EXIT DISCHARGE DOORS SHALL BE PERMITTED TO BE LOCKED | | | FROM THE STAIRWAY SIDE. STAIRWAY DOORS THAT ARE LOCKED | | | FROM THE STAIRWAY SIDE SHALL BE CAPABLE OF BEING | | | UNLOCKED SIMULTANEOUSLY WITHOUT UNLATCHING UPON A | | | SIGNAL FROM THE FIRE COMMAND CENTER. | | | | | | 3O)(4) 403.5.3.1 STAIRWAY COMMUNICATION SYSTEM. A | | | TELEPHONE OR OTHER TWO-WAY COMMUNICATIONS SYSTEM | | | CONNECTED TO AN APPROVED CONSTANTLY ATTENDED STATION | | | SHALL BE PROVIDED AT NOT LESS THAN EVERY FIFTH FLOOR IN | | | EACH STAIRWAY WHERE THE DOORS TO THE STAIRWAY ARE | | | LOCKED. | | | | | | 3O)(5) 403.5.5 LUMINOUS EGRESS PATH MARKINGS. LUMINOUS | | | EGRESS PATH MARKINGS SHALL BE PROVIDED IN ACCORDANCE | | | WITH 2010 FBC-B SECTION 1024. | | | | | | 3O)6) A CUT SECTION THROUGH THE BUILDING SHOWING WHICH | | | STAIRWELLS SERVICE WHICH SUITES SINCE THE FLOORS WITH 3 | | | SUITES USE STAIRWELLS 2 & 3 SO FIRE FIGHTERS WILL KNOW | | | WHICH STAIRWELLS AND FIREMEN?S ELEVATORS TO USE FOR | | | FIREFIGHTING AND OR EMERGENCIES. 107.2.1.3 ADDITIONAL | | | INFORMATION REQUIRED. | | | | | | 3P) PLEASE PROVIDE WHERE COMPLIANCE WITH THE 2010 FBC-B | | | SECTION 403.3.2 WATER SUPPLY TO REQUIRED FIRE PUMPS. | | | REQUIRED FIRE PUMPS SHALL BE SUPPLIED BY CONNECTIONS TO | | | A MINIMUM OF TWO WATER MAINS LOCATED IN DIFFERENT | | | STREETS. SEPARATE SUPPLY PIPING SHALL BE PROVIDED | | | BETWEEN EACH CONNECTION TO THE WATER MAIN AND THE | | | PUMPS. EACH CONNECTION AND THE SUPPLY PIPING BETWEEN | | | THE CONNECTION AND THE PUMPS SHALL BE SIZED TO SUPPLY | | | THE FLOW AND PRESSURE REQUIRED FOR THE PUMPS TO | | | OPERATE. | | | | | | EXCEPTION: TWO CONNECTIONS TO THE SAME MAIN SHALL BE | | | PERMITTED PROVIDED THE MAIN IS VALVED SUCH THAT AN | | | INTERRUPTION CAN BE ISOLATED SO THAT THE WATER SUPPLY | | | WILL CONTINUE WITHOUT INTERRUPTION THROUGH AT LEAST ONE | | | OF THE CONNECTIONS. TO BE APPROVED BY THE FIRE | | | DEPARTMENT. | | | | | | 3R) THE LAUNDRY ROOM WILL NEED TO MEET FAIR HOUSING, AT | | | LEAST ONE OF EACH TYPE OF APPLIANCES PROVIDED IN EACH | | | LAUNDRY AREA, EXPECT THAT LAUNDRY ROOMS SERVING COVERED | | | MULTIPLE-FAMILY DWELLINGS WOULD NOT BE REQUIRED TO HAVE | | | FRONT-LOADING WASHERS IN ORDER TO MEET THE REQUIREMENTS | | | OF 100.205?(1). (WHERE FRONT LOADING WASHERS ARE NOT | | | PROVIDED, MANAGEMENT WILL BE EXPECTED TO PROVIDE | | | ASSISTANCE DEVICES ON REQUEST IF NECESSARY TO PERMIT A | | | RESIDENT TO USE A TOP LOADING WASHER. ANSI | | | A117.1SECTION 4.32.6. ALSO IF COIN OPERATED VENDING | | | MACHINES ARE AVAILABLE ANSI A117.1 4.25 OPERATING | | | MECHANISMS. | | | | | | 3S) THE PLANS SHOW AT THE ENTRY LEVEL OF THE LOBBY A | | | RECEPTION/ REGISTRATION DESK. PLEASE PROVIDE COMPLIANCE | | | WITH FAIR HOUSING SPECIFICATION OF ANSI 4.31 ALSO SEE | | | REACH RANGES. | | | | | | 3T) THIS COMMENT WILL STAND FOR ALL FLOORS WITH | | | MULTIPLE R2 DWELLING UNITS ON THE SAME FLOOR OR | | | DWELLING UNITS ABOVE OR BELOW THE OCCUPIED UNIT. PLEASE | | | PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH: | | | | | | 3T)(1) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND. | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | | | 3T)(2) FBC-B 2014 1207.2 AIR-BORNE SOUND. | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | | E 90. | | | | | | 3T)(3) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2. | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | | | 3U) THE STRUCTURAL SHEETS INDICATE THE THICKNESS OF THE | | | FLOOR SLABS FOR THE MOST PART. I COULD NOT IDENTIFY THE | | | THICKNESS OF THE FLOOR SLABS FOR SHEETS: | | | 0360-S2.01M | | | 361-S2.02 GUEST SUITES LEVELS 2 & 3 | | | S361-S2.02 LEVEL 2 | | | S362-S2.02A POOL DECK FRAMING | | | | | | LEVEL DECK 1 (LOBBY) IS 12 INCH DECK | | | ALL OTHER DECKS ARE 10 INCH WITH EXCEPTION OF LEVEL 20 | | | WHICH IS ? OF DECK 14 INCHES DECK. | | | | | | | | | 4) SHEET 014-A0-33/ 082-A2-03: 2ND LEVEL GUEST SUITES. | | | | | | 4A) THE PLANS INDICATE 3 FLOORS OF GUEST SUITES. THE | | | TERM GUEST SUITES LEAD ONE TO BELIEVE THAT THE SUITES | | | ARE FOR SHORT TERM USE. IT IS UNCLEAR IF THESE UNITS | | | SHOULD BE REVIEWED UNDER FAIR HOUSING OR IF THEY SHOULD | | | BE REVIEWED UNDER THE FLORIDA ACCESSIBILITY CODE OR | | | BOTH. PLEASE SEE 2010 FBC-ACCESSIBILITY CODE | | | DEFINITIONS: RESORT CONDOMINIUM. (SECTION 509.242, | | | F.S.). A RESORT CONDOMINIUM IS ANY UNIT OR GROUP OF | | | UNITS IN A CONDOMINIUM, COOPERATIVE, OR TIME-SHARE PLAN | | | WHICH IS RENTED MORE THAN THREE TIMES A CALENDAR YEAR | | | FOR PERIODS OF LESS THAN 30 DAYS OR ONE CALENDAR MONTH, | | | WHICHEVER IS LESS, OR WHICH IS ADVERTISED OR HELD OUT | | | TO THE PUBLIC AS A PLACE REGULARLY RENTED FOR PERIODS | | | OF LESS THAN 30 DAYS OR ONE CALENDAR MONTH, WHICHEVER | | | IS LESS (SEE ALSO, PLACES OF LODGING). | | | | | | 4B) THERE IS A DISCREPANCY IN PLANS IT WOULD APPEAR. | | | SHEET 014-A0-33 LEVEL 2 GUEST SUITES IT APPEARS THE | | | MECHANICAL UNIT HP-1IN GUEST SUITES 11 & 12 ARE LOCATED | | | IN A ONE HOUR SHAFT WHEREAS THE UNITS 9 & 10 THE UNITS | | | ARE NOT LOCATED IN A RATED WALL. IT APPEARS IN UNITS 11 | | | & 12 THERE IS A VERTICAL 8X16 INCH EXHAUST DUCT NOT | | | SHOWN IN A SHAFT, MECHANICAL SHEETS INDICATE THAT IN | | | SOME AREA 2 HOUR FLAME BAR IS TO BE INSTALLED. PLEASE | | | PROVIDE DETAILED INFORMATION IN RESPONSE AS TO WHAT | | | AREAS ARE TO BE SHAFTS, HOUR RATING OF SHAFTS, WHERE | | | THE FLAME BAR IS TO BE INSTALLED AND FIRE STOPPING | | | ASSEMBLIES FOR THROUGH PENETRATIONS. THIS COMMENT WILL | | | BE COMMON FOR THE 3 FLOORS OF GUEST SUITES. 2010 FBC-B | | | 708.2.4 /716.6 HORIZONTAL ASSEMBLIES. THIS CONDITION | | | APPEARS ON THE 3RD LEVEL OF GUEST SUITES AS WELL. | | | | | | 4C) SUITE # 7 & 11 IS MISSING THE SHOWER ENCLOSURE ON | | | 014-A0-33. 107.2.1.3 ADDITIONAL INFORMATION REQUIRED. | | | | | | 4D) SUITE # 5 & 9 IS MISSING THE SHOWER ON SHEET | | | 014-A0-33. 107.2.1.3 ADDITIONAL INFORMATION REQUIRED. | | | | | | 5) SHEET 014-A)-33/ 081-A2-02: 2ND LEVEL AMENITIES/ 3RD | | | LEVEL GUEST SUITES. | | | 5A) SHEET 081-A2-02, STAIR # 1 ON THE 3RD LEVEL OF THE | | | GUEST ROOMS IS MISSING THE 1 ? HR. FIRE RATED DOOR. | | | 2010 FBC-B TABLE 715.4. | | | | | | 5B) SHEET 014-A)-33 STAIR # 1 IS MISSING THE | | | ILLUSTRATED DOWN PORTION OF STAIRS IN THE STAIRWELL | | | ENCLOSURE. 107.2.1.3 ADDITIONAL INFORMATION, TYPO. | | | | | | 5C) SHEET 081-A2-02 IS MISSING BOTH THE WALL & DOOR | | | IDENTIFICATION TAGS. CODE COMPLIANCE CANNOT BE | | | DETERMINED. 107.2.1.3 ADDITIONAL INFORMATION IS | | | REQUIRED. | | | | | | 5D) SHEET 014-A)-33 IS THE 2ND LEVEL OF THE ATRIUM. | | | THIS SHEETS DEPICTS THE 2ND FLOOR OF THE ATRIUM. WHAT | | | THE LIFE SAFETY SHEETS FAIL TO PROVIDE IS THE 1 HOUR | | | FIRE BARRIER (2010 FBC-B 404.6) CONSTRUCTED IN | | | ACCORDANCE WITH SECTION 707. THE PLANS DO NOT SHOW A | | | CUT SECTION WHERE ONE OF THE EXCEPTIONS WAS TAKEN. ONE | | | HOUR FIRE RATED WALLS WOULD BE REQUIRED WITH ANY SPACE | | | THAT COMMUNICATED WITH THE ATRIUM AND OPENING | | | PROTECTIVE IN COMPLIANCE WITH 2010 FBC-B TABLE 715.4. | | | SMOKE CONTROL IS NOT REQUIRED SINCE THIS IS A 2 STORY | | | ATRIUM. PLEASE NOTE THE 3 LEVELS OF THE R2 GUEST ROOMS | | | TRAVEL THROUGH A 1 HOUR FIRE RATED ACCESS CORRIDOR INTO | | | THE ATRIUM. | | | | | | 5E) . PLEASE SHOW HOW CODE COMPLIANCE WITH SECTION OF | | | THE 2010 FBC-B 404.8 INTERIOR FINISHES. THE INTERIOR | | | FINISHES OF WALLS AND CEILINGS OF THE ATRIUM SHALL NOT | | | BE LESS THAN CLASS B WITH NO REDUCTIONS IN CLASS FOR | | | SPRINKLER PROTECTION. | | | | | | 5F) THIS SHEET INDICATES THE BRIDGE SECTION OF THE 2ND | | | LEVEL IS INDICATED AS A MEZZANINE LOBBY. THE 2ND FLOOR | | | AREA THAT IS OPEN AND COMMUNICATES IS OVER ? OF THE | | | OPEN AREAS ALLOWED BY FBC-B 505.2 EXCEPTION # 2 FOR | | | TYPE I TYPE II BUILDINGS. THIS IS A TRUE 2 STORY | | | ATRIUM, FBC-B 404.6 ENCLOSURES OF ATRIUMS. | | | | | | 5G) SHEET 014-A0-33 POOL DECK STAIR # 6 & 7 SHOW THE | | | USE OF AN AREA OF RESCUE ASSISTANCE. THE 2010 FBC-B | | | 1007.1 ACCESSIBLE MEANS OF EGRESS. ACCESSIBLE MEANS OF | | | EGRESS SHALL BE PROVIDED IN ACCORDANCE WITH THE | | | APPLICABLE SECTIONS OF THE FLORIDA BUILDING CODE, | | | ACCESSIBILITY. | | | 2010 FBC-ACCESSIBILITY CODE. ACCESSIBLE MEANS OF EGRESS | | | . 207.1 GENERAL. MEANS OF EGRESS SHALL COMPLY WITH | | | SECTION 1003.2.13 OF THE INTERNATIONAL BUILDING CODE | | | (2000 EDITION AND 2001 SUPPLEMENT) OR SECTION 1007 OF | | | THE INTERNATIONAL BUILDING CODE (2003 EDITION) | | | (INCORPORATED BY REFERENCE, SEE "REFERENCED STANDARDS" | | | IN CHAPTER 1). | | | PLEASE SHOW FULL COMPLIANCE FOR THE AREA OF REFUGE | | | ASSISTANCE, 2003 IBC-B REQUIREMENTS 1007.6.(1-7) & | | | 1007.8(1-3). | | | | | | 5H) DEPENDING ON THE CLASSIFICATION AND OR OF THE | | | DINING ROOM, BEAUTY PARLOR AND GUEST ROOMS THERE MAYBE | | | ELEMENTS OF THIS BUILDING THAT MAY FALL UNDER THE 2010 | | | FBC-ACCESSIBILITY CODE. THE POOL DECK AND ACCESS TO THE | | | POOL WOULD THEN NEED TO MEET THE REQUIREMENTS OF 1009. | | | SWIMMING POOLS AND SPAS AS WELL AS WHERE PROVIDED, POOL | | | LIFTS SLOPED ENTRIES, TRANSFER WALLS, TRANSFER SYSTEMS, | | | AND POOL STAIRS SHALL COMPLY WITH 1009. IF THE END | | | RESULT OF THE RESEARCH IS COMPLETED AND ONLY FAIR | | | HOUSING IS TO BE APPLIED THEN ONLY ACCESS TO THE POOL | | | DECK WILL BE A FACTOR. | | | | | | 5I) PLEASE NOTE THE POOL DECK DOES SHOW STEPS BUT THERE | | | ARE NO RAMPS DESIGNATED ON THE PLANS FOR AN ACCESSIBLE | | | ROUTE TO THE LOWER POOL DECK AREA. FAIR HOSING ANSI | | | A117.1 4.3 (C) CONNECTING ACCESSIBLE BUILDING OR | | | FACILITY ENTRANCES WITH ACCESSIBLE SPACES AND ELEMENTS | | | WITHIN THE BUILDING OR FACILITY, INCLUDING ADAPTABLE | | | DWELLING UNITS. | | | | | | 5J) PLEASE PROVIDE FAIR HOUSING COMPLIANCE FOR THE | | | STEAM ROOMS AND SAUNAS. FAIR HOUSING COMMON USE SPACES | | | AND FACILITIES. WHEN ANSI DOES NOT CONTAIN | | | SPECIFICATIONS FOR SPECIFIC FACILITIES OR FEATURE IN | | | QUESTION RELATED HUMAN FACTORS AND PERFORMANCE | | | SPECIFICATIONS MUST BE USED TO ACHIEVE ACCESSIBILITY. | | | SUCH SPECIFICATIONS INCLUDE, BUT ARE NOT LIMITED TO, | | | 4.2 SPACE ALLOWANCES AND REACH RANGES, 4.3 ACCESSIBLE | | | ROUTE, 4.4 PROTRUDING OBJECTS, 4.5 GROUND & FLOOR | | | SURFACES, AND 4.25 OPERATING MECHANISMS. | | | | | | 5K) SHEET 014-A0-33 THE LOWER POOL DECK IT APPEARS | | | THERE IS ONLY ONE RAMP (NOT MARKED, NOR ELEVATION | | | CHANGES GIVEN) BETWEEN THE POOL DECK AND POOL THERE ARE | | | 116 OCCUPANTS AND WHAT APPEARS TO BE ONLY ONE | | | ACCESSIBLE MEANS OF EGRESS. PLEASE SHOW COMPLIANCE | | | WITH: 2010 FBC-BUILDING CODE 1007.1 ACCESSIBLE MEANS OF | | | EGRESS. ACCESSIBLE MEANS OF EGRESS SHALL BE PROVIDED IN | | | ACCORDANCE WITH THE APPLICABLE SECTIONS OF THE FLORIDA | | | BUILDING CODE, ACCESSIBILITY. | | | 2010 FBC-ACCESSIBILITY CODE SECTION 207.1 MEANS OF | | | EGRESS SHALL COMPLY WITH SECTION 1003.2.13 OF THE | | | INTERNATIONAL BUILDING CODE (2000 EDITION AND 2001 | | | SUPPLEMENT) OR SECTION 1007 OF THE INTERNATIONAL | | | BUILDING CODE (2003 EDITION). | | | 2003 IBC-B 1007.1 WHERE MORE THAN ONE MEANS OF EGRESS | | | IS REQUIRED BY SECTIONS 1014.1 OR 1018.1 FROM ANY | | | ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF THE SPACE | | | SHALL BE SERVED BY NOT LESS THAN TWO MEANS OF EGRESS. | | | | | | 6) SHEETS 015-A0-34 LEVELS 5-10. 11-17 (TIER 1) LEVELS | | | 18-19 TIER 2. / 083-A2-05 LEVEL 5/ 084-A2-06 LEVELS | | | 6-9, 11 TIER 1; | | | 6A) THIS COMMENT IS A COMMON COMMENT FOR ALL DWELLING | | | UNITS TIER 1 LEVELS 5-9 &11. THE LIFE SAFETY PLAN SHOWS | | | (2) REQUIRED COMMON PATHS OF TRAVEL BECAUSE THEY ARE | | | OVER THE 125 FEET REQUIRED BY 2010 FBC-B 1014.3 | | | EXCEPTION # 4. | | | | | | 6A) (1)THE PLANS SHOW THE 1ST COMMON PATH OF TRAVEL | | | EXITING THROUGH THE FRONT ENTRY DOORS THROUGH AN | | | ELEVATOR LOBBY, THE LIFE SAFETY PLANS WILL NEED TO | | | INDICATE IF THE ELEVATOR HOIST WAYS ARE PRESSURIZED TO | | | ALLOW EXITING THROUGH THE ELEVATOR LOBBY. 2010 FBC-B | | | 708.14.1 ELEVATOR LOBBIES. | | | | | | 6A)(2) THE 2ND ISSUE IS THE COMMON PATH OF TRAVEL | | | THROUGH THE LAUNDRY/ STORAGE/ UTILITY ROOM. PLEASE SEE | | | THE 2010 FBC-B SECTION 1014.2.1(4) 4. EGRESS SHALL NOT | | | PASS THROUGH KITCHENS, STORAGE ROOMS, CLOSETS OR SPACES | | | USED FOR SIMILAR PURPOSES. NOTE THE EXCEPTION IS ONLY | | | FOR A KITCHEN AREA SERVING ADJOINING ROOMS CONSTITUTING | | | PART OF THE SAME DWELLING UNIT OR SLEEPING UNIT. | | | | | | 6B) COMMON COMMENT FOR ALL FLOORS. EXITING CAPACITY | | | ANALYSIS FOR ALL TIERS SHOW A 36 INCH DOORWAY AND THE | | | EXIT CAPACITY AT 180 OCCUPANTS. THIS WOULD MEAN YOU | | | HAVE OFFSET HINGES ON THE EXIT DOORS SO THERE IS A FULL | | | 36 INCHES CLEAR WIDTH FROM THE FACE OF THE DOOR WHEN | | | OPEN AT 90 DEGREES TO THE OPPOSING LATCH SIDE OF THE | | | DOOR AND NOT INCLUDING THE DOOR STOP. SEE 2010 FBC-B | | | 1008.1.1. CLEAR OPENINGS OF DOORWAYS WITH SWINGING | | | DOORS SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR | | | AND THE STOP, WITH THE DOOR OPEN 90 DEGREES. THE ACTUAL | | | ALLOWABLE MAXIMUM OCCUPANT LOAD IS CLOSER TO 167. | | | | | | 7) SHEET 016-A0-35 LEVELS 20 & 21 / 090-A2-20 LEVEL 20 | | | REFERS TO SHEET 089- A2.18 FOR UNITS A & B. SHEET | | | 090-A2-20 FOR UNIT C. SAME COMMENTS AND ISSUES AS | | | COMMENTS 6A AND 6B. | | | | | | 8) SHEET 017-A0-36 LIFE SAFETY PLANS FOR LEVEL 22 & 23/ | | | 092-A2-22 & 093-A2-23. SAME COMMENTS AND ISSUES AS | | | COMMENTS 6A AND 6B. | | | | | | 9) SHEET 017-A0-36 LIFE SAFETY PLANS FOR LEVEL 22 & 23/ | | | SHEET 093-A2-23. ON NEITHER THE LIFE SAFETY PLAN NOR | | | THE ARCHITECTURAL SHEET ARE THE WALLS FILED IN TO SEE | | | IF THE TRAVEL DISTANCES SHOWN ARE CORRECT. 107.2.1.3 | | | ADDITIONAL INFORMATION IS REQUIRED. 2010 FBC-B 1014.3 | | | EXCEPTION # 4. | | | | | | 10) SHEET 018-A0-37 LEVELS 24 &25/ SHEET 094-A2-24 | | | LEVEL 24 & 095-A2-25. | | | 10A) UNIT PH-24N & PH25N HAS THE SAME ISSUES AS COMMENT | | | 6A)(1) ELEVATOR LOBBY & 6A)(2) EGRESS THROUGH STORAGE/ | | | UTILITY CLOSET / LAUNDRY ROOM. | | | | | | 10B) UNIT PH-24S &PH-25S ONLY NEEDS THE VERIFICATION OF | | | 2010 FBC-B 708.14.1 ELEVATOR LOBBY?S AND OR EXCEPTION. | | | | | | 11) SHEET 019-A)-38 LEVEL 26 MECHANICAL FLOOR - ROOF / | | | 096-A2-26 ARCH. MECHANICAL FLOOR | | | PLAN. A122-A2-76ALEVEL 26 NORTH, 411-M2-26 & 374.S2-26 | | | STRUCTURAL MECHANICAL ROOF FRAMING PLAN. | | | | | | 11A) SHEET 122-A2-76A NONE OF THE ARCHITECTURAL NOR | | | STRUCTURAL SHEETS, PROVIDE A ROOM & WALL IDENTIFICATION | | | TAG FOR THE WALL IN THE UPPER RIGHT CORNER OF THE | | | BUILDING, THE SAME WALL IS ALSO COMMON TO STAIR TOWER | | | #2 AND FIREMAN?S VESTIBULE 2601. ADDITIONAL INFORMATION | | | IS REQUIRED BOTH THE FIREMAN?S VESTIBULE (1HR.) AND THE | | | STAIR SHAFT(2 HR.) ARE FIRE RATED PROTECTED. 3007.4.2 & | | | 708.4. | | | | | | 11B) THIS SAME ROOM IN THE UPPER RIGHT HAND CORNER OF | | | THE MECHANICAL PENTHOUSE SHOWS MECHANICAL EQUIPMENT | | | SHEET 411-M2-26 MECHANICAL LEVEL 26. NONE OF THE PLANS | | | SHOW ACCESS TO THE EQUIPMENT IN THIS ROOM. USE OF ROOM | | | NOR IS THE ROOM IDENTIFIED ON NEITHER PLANS NOR ACCESS. | | | 2010 FBC-B 302.1 STRUCTURES OR PORTIONS OF STRUCTURES | | | SHALL BE CLASSIFIED WITH RESPECT TO OCCUPANCY IN ONE OR | | | MORE OF THE GROUPS LISTED BELOW. A ROOM OR SPACE THAT | | | IS INTENDED TO BE OCCUPIED AT DIFFERENT TIMES FOR | | | DIFFERENT PURPOSES SHALL COMPLY WITH ALL OF THE | | | REQUIREMENTS THAT ARE APPLICABLE TO EACH OF THE | | | PURPOSES FOR WHICH THE ROOM OR SPACE WILL BE OCCUPIED. | | | | | | 11C) THIS SAME ROOM SHOWS THE WALLS OF THIS ROOM | | | CONTINUING INTO THE EXTERIOR WALL TO THE CENTERLINE OF | | | THE SHEER WALL CONSTRUCTION? 107.2.1.3 ADDITIONAL | | | INFORMATION IS REQUIRED. TYPO. | | | | | | 11D) ROOM 2607 IS IDENTIFIED AS AN ELEVATOR STORAGE? IS | | | THE USE AN ELEVATOR MACHINE ROOM? 107.2.1.3 ADDITIONAL | | | INFORMATION IS REQUIRED. | | | | | | 11E) THE ROOM IN THE UPPER LEFT HAND CORNER OF THE | | | SHEET IS NOT IDENTIFIED, THE USE NOR IS THE DOOR. | | | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 11F) THE STAIRWELL 1 & 2 BOTH INDICATE HANDRAILS ON | | | BOTH SIDES OF THE STAIRS, THE PLANS ARE NOT CLEAR AS IF | | | THERE IS A KNEEWALL OR A GUARDRAIL AT THE LANDING | | | ADJACENT TO THE STAIRS. FBC-B 1013.1. | | | | | | 11G) DOORS ARE MISSING FROM THE DOOR SCHEDULE ON | | | 331-A8-11 DOORS 2602 & 2604A. 107.2.1.3 ADDITIONAL | | | INFORMATION IS REQUIRED. | | | | | | 11H)SHEET 122-A2-76A LEVEL 26 PLEASE NOTE ROOFTOP AND | | | FLOOR ELEVATION TAGS ARE NOT PROVIDED. | | | EXTERIOR OF THE BUILDING GRID LINES ARE GIVEN TO THE | | | HIGH POINTS AND ROOF DRAINS AS TO THE HIGH AND LOW | | | POINTS AGAIN ELEVATION TAGS WERE NOT PROVIDED. WILL THE | | | ROOF DECK BE SLOPED OR WILL ROOFTOP INSULATION MAKE UP | | | THE DIFFERENCE IN HEIGHT, WHAT TYPE OF ROOF TOP | | | INSULATION WILL BE USED? 107.2.1.3 ADDITIONAL | | | INFORMATION REQUIRED, PLANS LACKING DETAILS OR SECTIONS | | | THROUGH TO LOCATE DOCUMENTS WITH THIS INFORMATION. | | | | | | 11I) SHEET 171-A5-06 PLEASE NOTE NONE OF THE WALLS NOR | | | DOORS ARE PROVIDED WITH IDENTIFICATION TAGS, PLANS ARE | | | INCOMPLETE, 107.2.1.3 ADDITIONAL INFORMATION IS | | | REQUIRED. | | | | | | 11J) SHEET 171-A5-06 AND 096-A2-26 THERE IS A | | | DISCREPANCY IN THE PLANS, SHEET 096-A2-26 HAS AN | | | ADDITIONAL DOOR INTO THE ELEVATOR CONTROL ROOM 3, 4 &6. | | | | | | 11K) SHEET 171-A5-06, 096-A2-26 & 374-S2-26 NONE OF | | | THESE SHEETS DEPICT A SECTION THROUGH CORRIDOR 2604 AS | | | TO IF THIS IS WITHIN THE BUILDING OR ON THE EXTERIOR OF | | | THE BUILDING. AS OF WHAT MATERIALS IT WILL BE | | | CONSTRUCTED FROM. THE STRUCTURAL DRAWING 3374-S2-26 | | | SHOWS A VERTICAL TUBE, THE SIZE, MATERIAL, SPACING NOR | | | ATTACHMENT DETAILS ARE NOT PROVIDED. INCOMPLETE | | | PLANS.107.2.1.3. ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 11M) SHEET 096-A2-26 SHOWS WHAT APPEARS TO BE A | | | MECHANICAL EQUIPMENT SCREEN. THE STRUCTURAL SHEETS DO | | | NOT PROVIDE DETAILS OF THIS SYSTEM. PLEASE PROVIDE CODE | | | COMPLIANCE WITH 2010 FBC-B SECTIONS; | | | | | | 1509.6 MECHANICAL EQUIPMENT SCREENS. MECHANICAL | | | EQUIPMENT SCREENS SHALL BE CONSTRUCTED OF THE MATERIALS | | | SPECIFIED FOR THE EXTERIOR WALLS IN ACCORDANCE WITH THE | | | TYPE OF CONSTRUCTION OF THE BUILDING. WHERE THE FIRE | | | SEPARATION DISTANCE IS GREATER THAN 5 FEET (1524 MM), | | | MECHANICAL EQUIPMENT SCREENS SHALL NOT BE REQUIRED TO | | | COMPLY WITH THE FIRE-RESISTANCE RATING REQUIREMENTS. | | | WIND DESIGN CRITERIA NOT GIVEN. | | | | | | 1509.6.1 HEIGHT LIMITATIONS. MECHANICAL EQUIPMENT | | | SCREENS SHALL NOT EXCEED 18 FEET (5486 MM) IN HEIGHT | | | ABOVE THE ROOF DECK, AS MEASURED TO THE HIGHEST POINT | | | ON THE MECHANICAL EQUIPMENT SCREEN. | | | | | | 11N) SHEET 096-A2-26 THE MECHANICAL EQUIPMENT SCREEN | | | APPEARS TO HAVE BRACING LEGS, MATERIAL NOT KNOWN, SIZE | | | OF MATERIAL NOT KNOWN, SPACING NOT GIVEN NOR THE | | | ATTACHMENT TO NEITHER THE EQUIPMENT SCREEN NOR THE WALL | | | OR FLOOR ASSEMBLY. PLANS NOT COMPLETE. 107.2.1.3 | | | ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 11O) SHEET 096-A2-26 THE MECHANICAL EQUIPMENT SCREEN | | | BRACING SYSTEM AS DRAWN HAS LEGS THAT GO INTO THE | | | CORRIDOR 2604 BLOCKING ACCESS, BLOCKING ENTRY TO A | | | EXTERIOR MECHANICAL ROOM 2603 AND ALSO TO ROOM 2606. | | | PLEASE CORRECT THESE AREAS. | | | | | | 12) SHEET 431-M4-01 MECHANICAL DETAILS, DETAIL 20 | | | COOLING TOWER VIBRATION ISOLATOR DETAIL TO BE REVIEWED | | | BY THE STRUCTURAL ENGINEER OF RECORD, AND WITH THEIR | | | SHOP DRAWING STAMP OF APPROVAL. PLEASE NOTE THE | | | STRUCTURAL BASE OR SUPPORT WILL NEED TO BE DESIGNED BY | | | THE STRUCTURAL ENGINEER OR HIS DELEGATE WITH THE | | | STRUCTURAL ENGINEER?S APPROVAL BEFORE SUBMITTAL TO THE | | | BUILDING DEPARTMENT FOR REVIEW. | | | FL 61G-15-30.006 (3) THE DELEGATED ENGINEER SHALL | | | FORWARD THE DELEGATED ENGINEERING DOCUMENTS TO THE | | | ENGINEER OF RECORD FOR REVIEW. | | | | | | | | | 13) SHEET 431-M4-01 MECHANICAL DETAILS EQUIPMENT | | | SUPPORT CURB DETAIL & THYBAR VIBRATION CURB III DETAIL | | | FOR OAU-1 & 2. PLEASE PROVIDE THE PRODUCT APPROVALS FOR | | | CURB DETAILS. TO BE REVIEWED BY THE STRUCTURAL ENGINEER | | | OF RECORD, AND WITH THEIR SHOP DRAWING STAMP OF | | | APPROVAL. PLEASE NOTE THE STRUCTURAL ANCHOR TO THE BASE | | | OR SUPPORT AS WELL AS THE UNIT TO THE CURB FOR MOMENT | | | OF OVERTURNING, WILL NEED TO BE DESIGNED BY THE | | | STRUCTURAL ENGINEER OR HIS DELEGATE WITH THE STRUCTURAL | | | ENGINEER?S APPROVAL BEFORE SUBMITTAL TO THE BUILDING | | | DEPARTMENT FOR REVIEW. | | | FL 61G-15-30.006 (3) THE DELEGATED ENGINEER SHALL | | | FORWARD THE DELEGATED ENGINEERING DOCUMENTS TO THE | | | ENGINEER OF RECORD FOR REVIEW. | | | | | | 14) SHEET 131-A3-21. | | | 14A) THROUGH THE CUT SECTION OF THE BUILDING THERE ARE | | | VARIOUS FLOORS (EXAMPLE ELEV. # 1 LEVELS 23-20, 15-12, | | | 10 IN THE UPPER PORTION OF THE ELEVATOR LOBBY A RED | | | OBJECT THAT EITHER IS HANGING FORM THE CEILING OR CLOSE | | | TO THE CEILING. THIS DEPICTED THROUGHOUT THE SHEET IN | | | VARIOUS ELEVATOR LOBBY LOBBIES? 107.2.1.3 ADDITIONAL | | | INFORMATION IS REQUIRED. | | | | | | 14B) ELEVATORS 2/4 DO NOT CONTINUE THROUGH TO THE ROOF. | | | PLEASE PROVIDE WHERE COMPLIANCE WITH SECTIONS OF THE | | | 2010 FBC-B CAN BE FOUND: | | | | | | 14B)(1) 3004.1 VENTS REQUIRED. HOISTWAYS OF ELEVATORS | | | AND DUMBWAITERS PENETRATING MORE THAN THREE STORIES | | | SHALL BE PROVIDED WITH A MEANS FOR VENTING SMOKE AND | | | HOT GASES TO THE OUTER AIR IN CASE OF FIRE. FOR R1 AND | | | R2 OCCUPANCIES VENTING IS REQUIRED. | | | | | | 14B)(2) 3004.2 LOCATION OF VENTS. VENTS SHALL BE | | | LOCATED AT THE TOP THE HOISTWAY AND SHALL OPEN EITHER | | | DIRECTLY TO THE OUTER AIR OR THROUGH NONCOMBUSTIBLE | | | DUCTS TO THE OUTER AIR. NONCOMBUSTIBLE DUCTS SHALL BE | | | PERMITTED TO PASS THROUGH THE ELEVATOR MACHINE ROOM, | | | PROVIDED THAT PORTIONS OF THE DUCTS LOCATED OUTSIDE THE | | | HOISTWAY OR MACHINE ROOM ARE ENCLOSED BY CONSTRUCTION | | | HAVING NOT LESS THAN THE FIRE-RESISTANCE RATING | | | REQUIRED FOR THE HOISTWAY. HOLES IN THE MACHINE ROOM | | | FLOORS FOR THE PASSAGE OF ROPES, CABLES OR OTHER MOVING | | | ELEVATOR EQUIPMENT SHALL BE LIMITED AS NOT TO PROVIDE | | | GREATER THAN 2 INCHES (51 MM) OF CLEARANCE ON ALL | | | SIDES. | | | | | | 14)(3) 3004.3 AREA OF VENTS. EXCEPT AS PROVIDED FOR IN | | | SECTION 3004.3.1, THE AREA OF THE VENTS SHALL NOT BE | | | LESS THAN 31/2 PERCENT OF THE AREA OF THE HOISTWAY NOR | | | LESS THAN 3 SQUARE FEET (0.28 M2) FOR EACH ELEVATOR | | | CAR, AND NOT LESS THAN 31/2 PERCENT NOR LESS THAN 0.5 | | | SQUARE FEET (0.047 M2) FOR EACH DUMBWAITER CAR IN THE | | | HOISTWAY, WHICHEVER IS GREATER. OF THE TOTAL REQUIRED | | | VENT AREA, NOT LESS THAN ONE-THIRD SHALL BE PERMANENTLY | | | OPEN. CLOSED PORTIONS OF THE REQUIRED VENT AREA SHALL | | | CONSIST OF OPENINGS GLAZED WITH ANNEALED GLASS NOT | | | GREATER THAN 1/8 INCH (3.2 MM) IN THICKNESS. | | | | | | | | | 15) SHEET 137-A3-31 DETAILS 1 & 2 & SHEET A0.23 | | | EXTERIOR SYSTEMS. | | | | | | 15A) BOTH INDICATE THE USE OF METAL WALL PANELS, THERE | | | ARE NO CUT SECTIONS INDICATING MORE INFORMATION ON THE | | | PANELS. COMPONENTS AND CLADDING FBC-B, 1609.6.4.4.1 | | | COMPONENTS & CLADDING. PLEASE SEE THE 2010 FBC-B | | | SECTION 1407.3 ARCHITECTURAL TRIM AND EMBELLISHMENTS. | | | MCM USED AS ARCHITECTURAL TRIM OR EMBELLISHMENTS SHALL | | | COMPLY WITH SECTIONS 1407.7 THROUGH 1407.14. | | | 1407.4 STRUCTURAL DESIGN. MCM SYSTEMS SHALL BE DESIGNED | | | AND CONSTRUCTED TO RESIST WIND LOADS AS REQUIRED BY | | | CHAPTER 16 FOR COMPONENTS AND CLADDING. | | | | | | 1407.5 APPROVAL. RESULTS OF APPROVED TESTS OR AN | | | ENGINEERING ANALYSIS SHALL BE SUBMITTED TO THE BUILDING | | | OFFICIAL TO VERIFY COMPLIANCE WITH THE REQUIREMENTS OF | | | CHAPTER 16 FOR WIND LOADS. 1407.6 WEATHER RESISTANCE. | | | | | | 15B) GLASS EXTERIOR HAND/ GUARD RAIL SYSTEMS. PLEASE | | | PROVIDE COMPLIANCE WITH FBC-B 1607.7.1 & SECTION 2407. | | | WILL THE BALCONY DEMISING GLASS WALL SECTIONS HAVE | | | PATTERNS IN THE GLASS OR SANDBLASTED GLASS IN THE | | | FRAMES? IF SO COMPLIANCE WITH 2404.3 | | | . 2404.3.3 VERTICAL PATTERNED GLASS. PATTERNED GLASS | | | SLOPED 15 DEGREES (0.26 RAD) OR LESS FROM VERTICAL IN | | | WINDOWS, CURTAIN AND WINDOW WALLS, DOORS AND OTHER | | | EXTERIOR APPLICATIONS SHALL BE DESIGNED TO RESIST THE | | | WIND LOADS IN SECTION 1609 FOR COMPONENTS AND CLADDING | | | ACCORDING TO THE FOLLOWING EQUATION: | | | FGW < 1.0 FGE (EQUATION 24-9) | | | 2404.3.5 VERTICAL SANDBLASTED GLASS. | | | SANDBLASTED GLASS SLOPED 15 DEGREES (0.26 RAD) OR LESS | | | FROM VERTICAL IN WINDOWS, CURTAIN AND WINDOW WALLS, | | | DOORS, AND OTHER EXTERIOR APPLICATIONS SHALL BE | | | DESIGNED TO RESIST THE WIND LOADS IN SECTION 1609 FOR | | | COMPONENTS AND CLADDING ACCORDING TO THE FOLLOWING | | | EQUATION: | | | FG< 0.5 FGE (EQUATION 24-12) | | | | | | 15C) 137-A3-31 DETAILS 1 & 2 & SHEET A0.23 EXTERIOR | | | SYSTEMS & 144-A4-01. DETAILS 10 & 11. BOTH THESE | | | DETAILS SHOW A 1 INCH AIR GAP BETWEEN THE EDGE OF THE | | | SLAB AND THE METAL SLAB EDGE COVER PLATE. | | | | | | | | | 16) SHEETS 138-A3-32, 108-A2-68A & DETAIL # 2/ | | | 278-A6-85C BALCONY DEMISING GLASS WALL. THIS WILL MEAN | | | THE GLASS HAND RAIL SYSTEM IS FULLY SUPPORTED BY THE | | | VERTICAL FRAMING ELEMENT. THERE IS NO CLEAR DETAIL IN | | | EITHER THE ARCHITECTURAL SHEETS NOR THE STRUCTURAL | | | SHEETS AS TO THE ANCHORAGE OF SYSTEM NOR THE SPACING OF | | | THE HANDRAIL. THERE IS NO COMMENT THESE DETAILS ARE TO | | | BE SUPPLIED FROM A DELEGATE ENGINEER EITHER. WITH FBC-B | | | 1607.7.1 & SECTION 2407. | | | | | | THE FLOOR PLAN 108-A2-68A DOES SHOW THE USE OF BALCONY | | | DEMISING GLASS WALL AND DETAIL 2/0278-A6.85C AS WELL AS | | | THE ELEVATION SHEET 137-A3-31. THE DETAIL 2 ON SHEET | | | 278-A6-85C APPEAR TO BE FOR INSULATED SPANDREL PANEL | | | BUT NOT FOR THE GLASSED DEMISING WALL. PLEASE SHOW HOW | | | CODE COMPLIANCE WILL BE ACHIEVED FOR SECTION 439.2 | | | SEPARATION WALLS. WALLS SEPARATING DWELLING UNITS IN | | | THE SAME BUILDING, WALLS SEPARATING SLEEPING UNITS IN | | | THE SAME BUILDING AND WALLS SEPARATING DWELLING OR | | | SLEEPING UNITS FROM OTHER OCCUPANCIES CONTIGUOUS TO | | | THEM IN THE SAME BUILDING SHALL BE CONSTRUCTED AS FIRE | | | PARTITIONS IN ACCORDANCE WITH SECTION 709. UL U# 419 IS | | | NOT A GLASS DEMISING WALL. | | | | | | 17) SHEET 157-A4-14 DETAIL 11 SHOWS THE INSTALLATION OF | | | A TERRA COTTA RAIN SCREEN. REFERENCES DETAIL 11/ | | | 157-A4-14 PLEASE PROVIDE COMPLIANCE WITH 2010 FBC-B | | | SECTIONS: | | | | | | 17A) 1403.2 WEATHER PROTECTION. | | | | | | 17B) 1403.3 STRUCTURAL. EXTERIOR WALLS, AND THE | | | ASSOCIATED OPENINGS, SHALL BE DESIGNED AND CONSTRUCTED | | | TO RESIST SAFELY THE SUPERIMPOSED LOADS REQUIRED BY | | | CHAPTER 16. | | | | | | 17C) 1405.9 TERRA COTTA. ANCHORED TERRA COTTA OR | | | CERAMIC UNITS NOT LESS THAN 15/8 INCHES (41 MM) THICK | | | SHALL BE ANCHORED DIRECTLY TO MASONRY, CONCRETE OR STUD | | | CONSTRUCTION. TIED TERRA COTTA OR CERAMIC VENEER UNITS | | | SHALL BE NOT LESS THAN 15/8 INCHES (41 MM) THICK WITH | | | PROJECTING DOVETAIL WEBS ON THE BACK SURFACE SPACED | | | APPROXIMATELY 8 INCHES (203 MM) O.C. THE FACING SHALL | | | BE TIED TO THE BACKING WALL WITH CORROSION-RESISTANT | | | METAL ANCHORS OF NOT LESS THAN NO. 8 GAGE WIRE | | | INSTALLED AT THE TOP OF EACH PIECE IN HORIZONTAL BED | | | JOINTS NOT LESS THAN 12 INCHES (305 MM) NOR MORE THAN | | | 18 INCHES (457 MM) O.C.; THESE ANCHORS SHALL BE SECURED | | | TO 1/4-INCH (6.4 MM) CORROSION-RESISTANT PENCIL RODS | | | THAT PASS THROUGH THE VERTICAL ALIGNED LOOP ANCHORS IN | | | THE BACKING WALL. THE VENEER TIES SHALL HAVE SUFFICIENT | | | STRENGTH TO SUPPORT THE FULL WEIGHT OF THE VENEER IN | | | TENSION. THE FACING SHALL BE SET WITH NOT LESS THAN A | | | 2-INCH (51 MM) SPACE FROM THE BACKING WALL AND THE | | | SPACE SHALL BE FILLED SOLIDLY WITH PORTLAND CEMENT | | | GROUT AND PEA GRAVEL. IMMEDIATELY PRIOR TO SETTING, THE | | | BACKING WALL AND THE FACING SHALL BE DRENCHED WITH | | | CLEAN WATER AND SHALL BE DISTINCTLY DAMP WHEN THE GROUT | | | IS POURED. | | | | | | 18) SHEETS 160-A4.15 PODIUM METAL FIN, 161-A4.16 PODIUM | | | METAL FIN, THE DETAIL # 2 ON SHEET 160 INDICATES A HSS | | | TUBE POST, REFER TO STRUCTURAL SHEETS. THE STRUCTURAL | | | SHEETS DO NOT PROVIDE DETAILS OF THIS STRUCTURAL TUBE. | | | 197.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 19) SHEET 162-A4-31 ROOF DETAILS: | | | 19A) BETWEEN THE DIFFERENT DETAILS THEY SHOW A | | | DIFFERENCE BETWEEN SPRAY FOAM INSULATION ON THE ROOF | | | DECK DETAIL 14 TO THE USE OF TAPERED INSULATION BOARD. | | | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | ENGINEERED DRAWINGS FOR THE TAPERED ROOF INSULATION | | | WILL BE REQUIRED, AND TO BE REVIEWED BY THE ENGINEER OF | | | RECORD BEFORE SUBMITTAL TO THE BUILDING DEPARTMENT. FL | | | 61G-15-30.006 (3) THE DELEGATED ENGINEER SHALL FORWARD | | | THE DELEGATED ENGINEERING DOCUMENTS TO THE ENGINEER OF | | | RECORD FOR REVIEW. | | | | | | 19B) DETAILS 3 & 4 BOTH SHOW A TILE DECK ABOVE THE | | | ROOFING SYSTEM. THE ROOFING SYSTEM WELL NEED TO PROVIDE | | | PRODUCT APPROVALS FOR WIND AS WELL AS ENGINEERING FOR | | | THE TILE DECK INSTALLATION THEY WILL MEET THE WIND | | | LOADS FOR THE LOCATION ON THE BUILDING.2010 FBC-B | | | COMPONENTS AND CLADDING. 1609.6.4.4.1 COMPONENTS & | | | CLADDING. | | | | | | 20) SHEETS 164-A4-41 AND 165-A4-41A CANOPY SYSTEMS | | | SHEETS ARE CONCEPTUAL DRAWINGS AT BEST, THERE ARE NO | | | PLANS IN THE STRUCTURAL DOCUMENTS PROVIDES STRUCTURAL | | | ELEMENTS OR LOADS TO BE RESISTED. THESE LOADS WILL NEED | | | TO BE KNOWN FOR THE ECCENTRIC LOADING ONTO THE FRAMING | | | MEMBERS. ONCE THE LOADS ARE KNOWN THEN THE STRUCTURAL | | | DRAWINGS WILL BE ABLE TO REACT TO THE ECCENTRIC LOADS | | | BEING PLACED ON THE VARIOUS COLUMNS AND BEAMS. IF THE | | | CANOPY IS TO BE DESIGNED BY A DELEGATE ENGINEER THEN | | | COMPLIANCE WITH FL 61G-15-30.006 WILL NEED TO BE MET. | | | FL 61G-15-30.006 (3) THE DELEGATED ENGINEER SHALL | | | FORWARD THE DELEGATED ENGINEERING DOCUMENTS TO THE | | | ENGINEER OF RECORD FOR REVIEW. | | | | | | 21) THIS REVIEW NO PRODUCT APPROVALS WERE SUBMITTED. | | | THE DESIGNER OF RECORD OR THE CONTRACTOR CAN ELECT TO | | | SUBMIT THE PRODUCT APPROVALS FOR THE EXTERIOR CLADDING | | | AS A DEFERRED SUBMITTAL PER: | | | 2010 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION 107.3.4.2 DEFERRED SUBMITTALS. FOR THE | | | PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS ARE | | | DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE NOT | | | SUBMITTED AT THE TIME OF THE APPLICATION AND THAT ARE | | | TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A | | | SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL | | | HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE | | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | | SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION | | | DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | 21A) 2010 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING | | | | | | FLORIDA DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. | | | 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION | | | SYSTEMS THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31)(A) EXTERIOR DOORS. ROOF HATCHES. | | | (B) WINDOWS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, CURBS, INTAKE AND | | | EXHAUST FANS ? | | | (E) SHUTTERS | | | (F) SKYLIGHTS | | | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C | | | STANDS | | | | | | | | | 21B) 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY | | | DCA RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN WRITING | | | BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | | | | 22) THE PLANS WERE SUBMITTED EARLY FOR REVIEW BEFORE | | | THE FOUNDATION PERMIT WOULD BE ISSUED. THE SUBMITTED | | | BUILDING PLANS WERE NOT 100% DRAWINGS AND WILL NEED TO | | | BE RESUBMITTED BEFORE A THROUGH REVIEW CAN BE | | | COMPLETED. | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | | COOPERATION. | | | A THOROUGH REVIEW CANNOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2017-01-30 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-01-30 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-01-30 |
Time |
15:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2016-12-08 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-12-08 |
Time |
12:05 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-12-08 |
Time |
11:54 |
Sent To |
|
|
| Notes |
| 2016-12-08 12:09:53 | PROVISO: | | | | | | FPL LETTER WILL BE PROVISO; WE WILL NEED COPY FOR OUR | | | RECORDS. AIC CALCS PENDING NEC 110.9-10 | | | NOTE TO RISER INDICATING SELECTIVE COORDINATION | | | REQUIRED FOR GFP OF MAINS SHOWN HAS BEEN PROVIDED. | | | STUDY REQUIRED. | | | | | | VAL PEREZ | | | *6717 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2016-08-03 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-08-03 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-07-28 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2016-08-03 11:48:20 | 2ND ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 | | | PENDING COMMENTS: | | | | | | 1. MAIN ELECTRICAL ROOMS MUST COMPLY WITH NEC 110.26C2, | | | THERE SHALL BE ONE ENTRANCE AT EACH END OF THE WORKING | | | SPACE. SHOW TWO MEANS OF EGRESS. PER OUR MEETING, | | | SECOND OPENING NOT REFLECTED. PLEASE SHOW LOCATION OF | | | SECOND MEANS OF EGRESS. | | | 2. SHEET E2-01- IDENTIFY ALL AREAS ON FLOOR PLAN. | | | MINIMUM CRITERIA FOR PLAN REVIEW, ALL PANEL AND CIRCUIT | | | DESIGNATIONS FOR LIGHTING FIXTURES WITH CIRCUIT NUMBERS | | | ASSIGNED TO EQUIPMENT SHOWN. SOME AREAS ARE STILL NOT | | | DESIGNATED. | | | 3. FPL LETTER WILL BE PROVISO; WE WILL NEED COPY FOR | | | OUR RECORDS. AIC CALCS PENDING NEC 110.9-10 | | | 4. COULDN?T LOCATE VOLTAGE DROP CALCULATIONS FOR | | | FEEDERS AND BRANCH PER FBC EC C405.7 | | | 5. NOTE TO RISER INDICATING SELECTIVE COORDINATION | | | REQUIRED FOR GFP OF MAINS SHOWN. | | | 6. NOTE THAT THE FIRE PUMP CONDUCTORS STATE COPPER ON | | | RISER AND ALUMINUM ON PANEL SCHEDULE. FIRE PUMP BREAKER | | | IN GDP PANEL TO COMPLY WITH NEC 695.6 AND 430.52 TABLE | | | 7. SHEET 2-54A- SEE KITCHEN AREAS NEXT TO CIRCUIT #7, | | | ADDRESS COUNTERTOP AREAS SPACING TO COMPLY WITH NEC | | | 210.52C1- NOT ADDRESSED PLEASE ADD A GENERAL NOTE | | | INDICATING NEC 210.52 KITCHEN SPACING REQUIREMENTS. | | | 8. COMMENTS MAY FOLLOW UPON RE-REVIEW. PLEASE FEEL FREE | | | TO CONTACT ME SHOULD YOU HAVE ANY QUESTIONS REGARDING | | | THIS PROJECT. | | | | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2016-02-10 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2016-02-10 |
Time |
06:37 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2016-02-08 |
Time |
15:03 |
Sent To |
|
|
| Notes |
| 2016-02-10 06:37:21 | INITIAL ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2010 | | | NFPA 70- 2008 NEC | | | COMMENTS: | | | | | | 1. GENERAL NOTES TO CONSTRUCTION DOCUMENTS: PLEASE | | | PROVIDE A BLOCK NOTE INDICATING THE REQUIRED SEPARATE | | | PERMITS AND DATA CUT SHEET SUBMITTALS FOR ALL SITE | | | LIGHTING AND ASSOCIATED EQUIPMENT, GENERATOR, ALL LOW | | | VOLTAGE SYSTEMS TO INCLUDE BUT NOT LIMITED TO FIRE | | | ALARM, ACCESS CONTROLS, CCTV, PHONE AND DATA, SIGNAGE, | | | WIRELESS SYSTEMS, ELEVATORS, CAR CHARGING STATIONS, | | | ETC. A NOTE WILL SUFFICE. | | | 2. SHEET E1.01- PLEASE ADD A GENERAL NOTE TO SHEET TO | | | INDICATE THE REQUIREMENTS OF NEC 300.5D3 AND TABLE | | | 300.5 FOR MINIMUM COVER REQUIREMENTS FOR CONDUITS AND | | | THE PLACEMENT OF A WARNING RIBBON FOR THE SERVICE | | | LATERAL CONDUCTORS SHOWN FOR THIS PROJECT. A NOTE WILL | | | SUFFICE | | | 3. SHEET E1.01- ADD A NOTE TO MAINTAIN ALL ELECTRICAL | | | EQUIPMENT ABOVE THE BASELINE FLOOD ELEVATION PER STATE | | | AND CITY REGULATORY AGENCIES. | | | 4. SHEET E2.0P1- SHOW ON FLOOR PLAN THE ELEVATOR PIT | | | CIRCUIT DESIGNATIONS FOR PIT LIGHTING, RECEPTACLES AND | | | PUMP EQUIPMENT AS NOTED IN NEC 620.24 A,B AND C | | | 5. SHEET E2.0P1- REFLECT ON FLOOR PLAN, PER FBC 107, | | | MINIMUM CRITERIA FOR PLAN REVIEW, ALL PANEL AND CIRCUIT | | | DESIGNATIONS FOR LIGHTING FIXTURES, RECEPTACLES AND | | | MECHANICAL DISCONNECT WITH CIRCUIT NUMBERS ASSIGNED TO | | | EQUIPMENT SHOWN. ALSO ID THE CIRCULATING FANS SHOWN. | | | 6. SHEET E2-0P2- REFLECT ON FLOOR PLAN, PER FBC 107, | | | MINIMUM CRITERIA FOR PLAN REVIEW, ALL PANEL AND CIRCUIT | | | DESIGNATIONS FOR LIGHTING FIXTURES, RECEPTACLES AND | | | MECHANICAL DISCONNECT WITH CIRCUIT NUMBERS ASSIGNED TO | | | EQUIPMENT SHOWN. ALSO ID THE CIRCULATING FANS AND | | | ROLLING DOORS | | | 7. SHEET E2-01- IDENTIFY ALL AREAS ON FLOOR PLAN. GFCI | | | PROTECTION REQUIRED WITHIN 6FT OF EVERY SINK PER NEC | | | 210.8B5, SEE LAUNDRY ROOM ADJACENT AREA. MINIMUM | | | CRITERIA FOR PLAN REVIEW, ALL PANEL AND CIRCUIT | | | DESIGNATIONS FOR LIGHTING FIXTURES, RECEPTACLES AND | | | MECHANICAL DISCONNECT WITH CIRCUIT NUMBERS ASSIGNED TO | | | EQUIPMENT SHOWN. | | | 8. SHEET E2-01L- SEE NOTE ABOVE REGARDING | | | IDENTIFICATION OF ALL ELECTRICAL OUTLETS, LUMINAIRES | | | ETC. FBC 107. ENTIRE SHEET TO BE ADDRESSED FOR A | | | COMPLETE REVIEW. | | | 9. SHEET E2-02- SAME AS ABOVE COMMENT #8. ALSO GFCI | | | PROTECTION IS REQUIRED FOR THE SPA AND RESTROOMS AREAS | | | SHOWN. | | | 10. SHEET E2-05 THROUGH E2-17, E2.18 THROUGH E2.26L- | | | SAME AS ABOVE COMMENT #8. FURTHER COMMENTS TO FOLLOW | | | UPON RE-REVIEW. | | | 11. SHEET 2.26L- PER NEC 700.20 SWITCH REQUIREMENTS- | | | 3WAY SWITCHES SHALL NOT BE USED AS SHOWN ON EMERGENCY | | | LIGHTING CIRCUITS. PLEASE CLARIFY DESIGN INTENT. | | | 12. SHEET 2-27- PROVIDE A NOTE TO INDICATE LIGHTNING | | | PROTECTION AND EQUIPMENT TO BE SUBMITTED UNDER SEPARATE | | | PERMIT. ALSO PROVIDE THE OBSTRUCTION LIGHT/AIRCRAFT | | | WARNING LIGHTS. | | | 13. SHEET 2-51A THROUGH 2-53A- SAME AS ABOVE COMMENT #8 | | | 14. SHEET 2-54A- SEE KITCHEN AREAS NEXT TO CIRCUIT #7, | | | ADDRESS COUNTERTOP AREAS SPACING TO COMPLY WITH NEC | | | 210.52C1 | | | 15. SHEET 2-54B- SEE KITCHEN AREAS NEXT TO CIRCUIT #7, | | | ADDRESS COUNTERTOP AREAS SPACING TO COMPLY WITH NEC | | | 210.52C1 | | | 16. SHEET 2-55A- SEE KITCHEN AREAS NEXT TO CIRCUIT #7, | | | ADDRESS COUNTERTOP AREAS SPACING TO COMPLY WITH NEC | | | 210.52C1 | | | 17. SHEET 2-55B- SEE KITCHEN AREAS NEXT TO CIRCUIT #7, | | | ADDRESS COUNTERTOP AREAS SPACING TO COMPLY WITH NEC | | | 210.52C1 | | | 18. SHEET 2-56A- SEE KITCHEN AREAS NEXT TO CIRCUIT #7, | | | ADDRESS COUNTERTOP AREAS SPACING TO COMPLY WITH NEC | | | 210.52C1 | | | 19. SHEET 2-56B- SEE KITCHEN AREAS NEXT TO CIRCUIT #7, | | | ADDRESS COUNTERTOP AREAS SPACING TO COMPLY WITH NEC | | | 210.52C1 | | | 20. SHEET 2-58B- SEE KITCHEN AREAS NEXT TO CIRCUIT #3, | | | ADDRESS COUNTERTOP AREAS SPACING TO COMPLY WITH NEC | | | 210.52C1 | | | 21. SHEET 2-59A- SEE KITCHEN AREAS NEXT TO CIRCUIT #7, | | | ADDRESS COUNTERTOP AREAS SPACING TO COMPLY WITH NEC | | | 210.52C1 | | | 22. RISER DIAGRAM AND PANEL SCHEDULES SHEET 5-01 | | | THROUGH E6-12- PLEASE PROVIDE AVAILABLE FAULT CURRENT | | | AVAILABLE AT THE FPL SERVICE. ATTACH TO DOCUMENTS | | | LETTER FROM FLORIDA POWER & LIGHT INDICATING AIC. SHOW | | | AIC CALCULATION BASED ON INFORMATION PROVIDED BY | | | UTILITY FOR APPROVAL. NEC 110.24 FBC 107 | | | 23. SHOW THE SIZE OF THE TAP BOX ON RISER DIAGRAM. FBC | | | 107 | | | 24. MAINS THAT ARE OVER 1000AMP 277/480VOLTS TO BE GFCI | | | PROTECTED. NEC 240.13 | | | 25. PROVIDE VOLTAGE DROP CALCULATIONS NOT ONLY FOR | | | FEEDERS BUT ALSO THE BRANCH CIRCUIT FBC EC 505.7 | | | 26. PANEL HR NOT ON PANEL SCHEDULE TO VERIFY LOADS AS | | | SHOWN ON RISER DIAGRAM, PLEASE CLARIFY. FBC 107 | | | 27. THE SUBMETTERING STANDBY POWER TO RESIDENTIAL UNITS | | | ARE TOO VAGUE AS FAR AS MEETING THE REQUIREMENTS OF NEC | | | 702.5A, B2. CLARIFY INTENT. | | | 28. WILL NEED TO CORRELATE PANEL DESIGNATIONS SHOWN | | | FEEDING FROM OTHER PANEL BOARDS; FOR EXAMPLE PANEL HS3 | | | FROM HS2, NO OVERCURRENT PROTECTION SHOWN ON PANEL | | | SCHEDULE. THIS IS JUST ONE EXAMPLE AS THIS CONDITION | | | REPEATS ITSELF THROUGHOUT DESIGN. PLEASE REVISE A SHOW | | | ALL CORRECTLY. FBC 107 | | | 29. THERE ARE MULTIPLE PANEL LOAD SCHEDULES THAT | | | REFLECT DIFFERENT AMPERAGES THAT THOSE SHOWN ON RISER | | | DIAGRAM. EXAMPLE ; SEE PANEL EM | | | 30. DESIGNATION OF PANEL BOARDS IS NOT ACCURATE. GEAR | | | LABELED M1 IS ALSO LABELED MDP1. M2 IS LABELED MDP2. | | | MAINTAIN CONSISTENCY TO PROVIDE AN ACCURATE REVIEW OF | | | CONDUCTOR?S SIZES ETC. FBC 107 | | | 31. ONE-LINE DIAGRAM TO REFLECT CONDUCTOR SIZES | | | THROUGHOUT. | | | 32. REVISIT LOAD CALCULATIONS FOR ACCURACY. SEE PANEL | | | GDP WHICH IS SHOWN WITH NO CALCULATED LOADS YET RISER | | | SHOWS LOADS OBVIOUSLY BEING DRAWN FROM THIS PANEL | | | BOARD. NEED TO REVIEW MULTIPLE PANELS WITH SAME | | | CONDITION. SELECTED CONDUCTORS ARE ALSO UNDERSIZED PER | | | NEC 310.16 FOR 250AL. AS SHOWN. TOO MANY ITEMS TO LIST. | | | NEC 220, FBC 107. | | | 33. CORRECT AMPERAGE FOR GDP PANEL BOARD SHOWN AT | | | 3000AMP ON RISER DIAGRAM BUT 800 AMPS MAIN BUS. PLEASE | | | CLARIFY. | | | 34. ATS #3 NOT SHOWN ON GDP PANEL BOARD SCHEDULE. SEE | | | RISER DIAGRAM. SAME SCENARIO REPEATS ITSELF THROUGHOUT | | | DESIGN. NEED TO ADDRESS. | | | 35. NOTE THAT CONNECTED CALCULATED LOADS AND TOTAL | | | DEMANDS ARE INACCURATE. ADDRESS PANEL BOARDS | | | CALCULATION, FOR EXAMPLE SEE PANEL P, LNR, AND HNR, | | | ETC. MULTIPLE PANEL BOARDS. NEC 220 FBC 107. | | | 36. MAIN ELECTRICAL ROOMS MUST COMPLY WITH NEC | | | 110.26C2, THERE SHALL BE ONE ENTRANCE AT EACH END OF | | | THE WORKING SPACE. SHOW TWO MEANS OF EGRESS. ALSO NEC | | | 110.26C3 REQUIRES PERSONNEL DOORS TO BE EQUIPPED WITH | | | PANIC HARDWARE AND OPEN IN THE DIRECTION OF EGRESS. A | | | NOTE WILL SUFFICE. | | | 37. PROVIDE INFORMATION ON DRAWINGS AND DATA SHEETS FOR | | | LIGHTING CONTROL PANEL, NOT ADDRESSED FOR REVIEW. | | | 38. ALL ELECTRICAL ROOMS THAT CONTAIN TRANSFORMER MUST | | | BE ID TO INDICATE IF TRANSFORMERS ARE BEING HUNG OR | | | NOT,TO VERIFY CLEARANCE REQUIREMENTS PER NEC 110.26. | | | SEE ROOM LEVEL 11, 18 AND 25. | | | 39. CLARIFY AS NO ELEVATOR MACHINE ROOMS ARE SHOWN TO | | | COMPLY WITH NEC 620.23 A,B AND C. | | | 40. SHOW ELECTRICAL REQUIREMENTS FOR THE GENERATOR FUEL | | | TANK. | | | 41. COMMENTS MAY FOLLOW UPON RE-REVIEW. PLEASE FEEL | | | FREE TO CONTACT ME SHOULD YOU HAVE ANY QUESTIONS | | | REGARDING THIS PROJECT. | | | | | | | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2016-12-13 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2016-12-13 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2016-12-13 |
Time |
|
Sent To |
I |
|
| Notes |
| 2016-12-13 10:28:45 | PLAN SUBMITTED WITH LANDSCAPING IS NOT IN CONFLICT WITH | | | CITY OF WPB PUBLIC UTILITIES. | | | | | | MANUEL JULIAN GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | PUBLIC WORKS DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | EMAIL: [email protected] | | | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS | | | /FORMS,-PERMITS-APPLICATIONS | | | | | | IMPORTANT MESSAGE: AS OF DECEMBER 20, 2015 THE CITY OF | | | WEST PALM BEACH | | | CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED, | | | MAKING KNOWN THAT "ALL BACKFLOW DEVICES MUST BE LEAD | | | FREE." | | | FOR MORE INFORMATION REFER TO THE LINK BELOW: | | | HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLI | | | CATIONS/BACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL | | | | | | | | | |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2016-03-31 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2016-03-31 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2016-03-31 |
Time |
|
Sent To |
Z |
|
| Notes |
| 2016-03-31 19:38:58 | RESPOND TO COMMENTS IN WIRTING: | | | | | | #1 FIRE HYDRANT FLOW TEST(S) SHALL BE NOTED ON CIVIL | | | PLAN WHERE SERVICES ENTER THE SITE. | | | | | | #2 ADDRESS FIRE REIVIEW COMMENTS AND REVISE ENGINEERING | | | DEVELOPMENT REVIEW SUBMITTAL. | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2017-02-01 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-02-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-01-30 |
Time |
08:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2016-12-22 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-12-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-12-22 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2016-12-22 14:50:48 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | | | | 1) THERE ARE NO INDICATIONS THAT THE PREVIOUS FIRE | | | COMMENTS WERE ADDRESSED. | | | | | | PLEASE PROVIDE THE APPLICABLE RESPONSES TO THE PREVIOUS | | | FIRE COMMENTS. | | | | | | | | | | | | 1) SHEET AO 32 - THE 2 DOORS OF THE EMERGENCY ROOM AND | | | THE DOOR TO THE POOL EQUIPMENTROOM SWING INTO THE EXIT | | | CORRIDOR - | | | | | | PER NFPA 101 CHAPTER 7, MEANS OF EGRESS | | | 7.2.1.4.3 DOOR LEAF ENCROACHMENT | | | 7.2.1.4.3.1 DURING ITS SWING, ANY DOOR LEAF IN A MEANS | | | OF EGRESS SHALL LEAVE NOT LESS THAN ONE-HALF OF THE | | | REQUIRED WIDTH OF AN AISLE, A CORRIDOR, A PASSAGEWAY, | | | OR A LANDING UNOBSTRUCTED AND SHALL NOT PROJECT NOT | | | MORE THAN 7 IN. INTO THE REQUIRED WIDTH OF AN AISLE, A | | | CORRIDOR, A PASSAGE WAY, OR A LANDING, WHEN FULLY OPEN, | | | UNLESS BOTH OF THE FOLLOWING CONDITIONS ARE MET: | | | (1) THE DOOR OPENING PROVIDES ACCESS TO A STAIR IN AN | | | EXISTING BUILDING. | | | (2) THE DOOR OPENING MEETS THE REQUIREMENTS THAT LIMITS | | | PROJECTION TO NOT MORE THAN 7 IN. INTO THE REQUIRED | | | WIDTH OF THE STAIR LANDING WHEN THE DOOR LEAF IS FULLY | | | OPEN. | | | | | | PLEASE REVIEW AND CORRECT OR JUSTIFY. | | | | | | | | | 2) SHEET AO 32 - A NOTE IS INDICATED STATING FOR A | | | STAIR WIDER THAN 44" "THE FOLLOWING FORMULA WAS | | | PROVIDED BY THE WEST PALM BEACH FIRE DEPARTMENT". | | | | | | I HAVE BEEN THE SOLE CONTACT FOR THE FIRE DEPARMTNAT | | | AND I DO NOT RECALL PROVIDING THIS FORMULA; HOWEVER, IT | | | CAN BE USED PER NFPA 101, CHAPTER 7, 7.3.3.2. | | | | | | HOWEVER, THE SUM OF THE CALCULATION PROVIDED APPEARS TO | | | BE INCORRECT. 60-44/.218 + 146.7 = 220; NOT 495 WHICH | | | IS INDICATED AND INCORRECT | | | | | | PLEASE REVIEW AND CORRECT OR JUSTIFY. | | | | | | | | | 3) SHEET AO 32 & ALL A2'S - THE FRONT DOORS TO ALL | | | UNITS ON EACH LIFE SAFETY PLAN SHEET INDICATE IT WITHIN | | | IN AN 1 HOUR ORANGE WALL. THE DOOR SCHEDULE SHEET | | | INDICATE THOSE DOORS AS U01A AND HAVE NO FIRE RATING. | | | | | | WHICH IS CORRECT ? | | | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | | 4) SHEET AO 32 - THE LOBBY LEVEL EXIT CAPACITY LOADS | | | ARE DIFFICULT TO FOLLOW AND THE FRONT LOBBY DOOR | | | APPEARS TO BE TOO SMALL. | | | | | | PLEASE PROVIDE A DETAILED EXIT LOAD CALCULATION FROM | | | EACH OCCUPANY AREA THAT EQUALS 89 AT THE FRONT DOOR. MY | | | CALCULATIONS INDICATE NEARLY MORE AT THE FRONT DOOR.100 | | | @ THE LOBBY, 27 @ THE LOBBY LOUNGE, 6 @ THE GUEST | | | SUITES, 185 @ COMBO # 2 STAIR,(48 FROM BELOW 137 ABOVE) | | | = 318. | | | | | | PLEASE REVIEW, CORRECT OR JUSTIFY. | | | | | | | | | 5) SHEET AO 32 - UNDER THE GENERAL NOTES # 6 IT | | | INDICATES FOR STAIRWAY # 3 NO REENTRY FOR LEVELS 23, | | | 24, 25. PER NFPA 101, CHAPTER 7 APPEARS TO BE IN | | | CONFLICT WITH REQUIRERMENT (3). | | | | | | 7.2.1.5.8.1 DOOR ASSEMBLIES ON STAIR ENCLOSURES SHALL | | | BE PERMITTED TO BE EQUIPPED WITH HARDWARE THAT PREVENTS | | | RE-ENTRY INTO THE INTERIOR OF THE BUILDING, PROVIDED | | | THAT ALL OF THE FOLLOWING CRITERIA ARE MET: | | | (1) THERE SHALL BE NOT LESS THAN TWO LEVELS WHERE IT IS | | | POSSIBLE TO LEAVE THE STAIR ENCLOSURE TO ACCESS ANOTHER | | | EXIT. | | | (2) THERE SHALL BE NOT MORE THAN FOUR STORIES | | | INTERVENING BETWEEN STORIES WHERE IT IS POSSIBLE TO | | | LEAVE THE STAIR ENCLOSURE TO ACCESS ANOTHER EXIT. | | | (3) RE-ENTRY SHALL BE POSSIBLE ON THE TOP STORY OR | | | NEXT-TO-TOP STORY SERVED BY THE STAIR ENCLOSURE, AND | | | SUCH STORY SHALL ALLOW ACCESS TO ANOTHER EXIT. | | | (4) DOOR ASSEMBLIES ALLOWING RE-ENTRY SHALL BE | | | IDENTIFIED AS SUCH ON THE STAIR SIDE OF THE DOOR LEAF. | | | (5) DOOR ASSEMBLIES NOT ALLOWING RE-ENTRY SHALL BE | | | PROVIDED WITH A SIGN ON THE STAIR SIDE INDICATING THE | | | LOCATION OF THE NEAREST DOOR OPENING, IN EACH DIRECTION | | | OF TRAVEL, THAT ALLOWS RE-ENTRY OR EXIT. | | | | | | | | | PLEASE REVIEW AND CORRECT OR JUSTIFY. | | | | | | | | | 6) SHEET FP 201 - FIRE CODE REFERENCES REMIAN | | | INCORRECT. PLEASE REVIEW AND ENSURE COMPLIANCE WITH THE | | | CURRENT FLORIDA FIRE PREVENTION CODE, 5TH EDITION AND | | | ALL APPLICABLE CODES REFERENCES CONTAINED WITHIN IT. | | | | | | | | | PLEASE REVIEW AND CORRECT - 1, 10, 13, 14, 20, 37, 88A | | | & 101. | | | | | | | | | 7) SHEET A5 27, AO 32 & A2 01 - THE DIMENSIONS OF THE | | | EAST OUTSIDE STAIR ARE NOT INDICATED AND CAN NOT BE | | | CONFIMRED TO MEET THE EGRESS REQUIREMENTS. I WAS UNABLE | | | TO IDENTIFY ANY SHEET WITH THE DIMENSIONS. | | | | | | PLEASE CORRECT OR PROVIDE THE REFERNECED SHEET | | | | | | | | | 8) SHEET A2 51A - A FIREPLACE IS INDICATED IN THE | | | LOUNGE 2; HOWEVER, NO FUEL SOURCE OR VENTING COULD BE | | | IDENTIFIED. | | | | | | PLEASE REVIEW AND CORRECT AND/OR IDENTIFY THE SHEET. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2016-08-24 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-08-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-08-12 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2016-08-23 09:29:54 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) SHEET AO 32 - THE 2 DOORS OF THE EMERGENCY ROOM AND | | | THE DOOR TO THE POOL EQUIPMENTROOM SWING INTO THE EXIT | | | CORRIDOR - | | | | | | PER NFPA 101 CHAPTER 7, MEANS OF EGRESS | | | 7.2.1.4.3 DOOR LEAF ENCROACHMENT | | | 7.2.1.4.3.1 DURING ITS SWING, ANY DOOR LEAF IN A MEANS | | | OF EGRESS SHALL LEAVE NOT LESS THAN ONE-HALF OF THE | | | REQUIRED WIDTH OF AN AISLE, A CORRIDOR, A PASSAGEWAY, | | | OR A LANDING UNOBSTRUCTED AND SHALL NOT PROJECT NOT | | | MORE THAN 7 IN. INTO THE REQUIRED WIDTH OF AN AISLE, A | | | CORRIDOR, A PASSAGE WAY, OR A LANDING, WHEN FULLY OPEN, | | | UNLESS BOTH OF THE FOLLOWING CONDITIONS ARE MET: | | | (1) THE DOOR OPENING PROVIDES ACCESS TO A STAIR IN AN | | | EXISTING BUILDING. | | | (2) THE DOOR OPENING MEETS THE REQUIREMENTS THAT LIMITS | | | PROJECTION TO NOT MORE THAN 7 IN. INTO THE REQUIRED | | | WIDTH OF THE STAIR LANDING WHEN THE DOOR LEAF IS FULLY | | | OPEN. | | | | | | PLEASE REVIEW AND CORRECT OR JUSTIFY. | | | | | | | | | 2) SHEET AO 32 - A NOTE IS INDICATED STATING FOR A | | | STAIR WIDER THAN 44" "THE FOLLOWING FORMULA WAS | | | PROVIDED BY THE WEST PALM BEACH FIRE DEPARTMENT". | | | | | | I HAVE BEEN THE SOLE CONTACT FOR THE FIRE DEPARMTNAT | | | AND I DO NOT RECALL PROVIDING THIS FORMULA; HOWEVER, IT | | | CAN BE USED PER NFPA 101, CHAPTER 7, 7.3.3.2. | | | | | | HOWEVER, THE SUM OF THE CALCULATION PROVIDED APPEARS TO | | | BE INCORRECT. 60-44/.218 + 146.7 = 220; NOT 495 WHICH | | | IS INDICATED AND INCORRECT | | | | | | PLEASE REVIEW AND CORRECT OR JUSTIFY. | | | | | | | | | 3) SHEET AO 32 & ALL A2'S - THE FRONT DOORS TO ALL | | | UNITS ON EACH LIFE SAFETY PLAN SHEET INDICATE IT WITHIN | | | IN AN 1 HOUR ORANGE WALL. THE DOOR SCHEDULE SHEET | | | INDICATE THOSE DOORS AS U01A AND HAVE NO FIRE RATING. | | | | | | WHICH IS CORRECT ? | | | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | | 4) SHEET AO 32 - THE LOBBY LEVEL EXIT CAPACITY LOADS | | | ARE DIFFICULT TO FOLLOW AND THE FRONT LOBBY DOOR | | | APPEARS TO BE TOO SMALL. | | | | | | PLEASE PROVIDE A DETAILED EXIT LOAD CALCULATION FROM | | | EACH OCCUPANY AREA THAT EQUALS 89 AT THE FRONT DOOR. MY | | | CALCULATIONS INDICATE NEARLY MORE AT THE FRONT DOOR.100 | | | @ THE LOBBY, 27 @ THE LOBBY LOUNGE, 6 @ THE GUEST | | | SUITES, 185 @ COMBO # 2 STAIR,(48 FROM BELOW 137 ABOVE) | | | = 318. | | | | | | PLEASE REVIEW, CORRECT OR JUSTIFY. | | | | | | | | | 5) SHEET AO 32 - UNDER THE GENERAL NOTES # 6 IT | | | INDICATES FOR STAIRWAY # 3 NO REENTRY FOR LEVELS 23, | | | 24, 25. PER NFPA 101, CHAPTER 7 APPEARS TO BE IN | | | CONFLICT WITH REQUIRERMENT (3). | | | | | | 7.2.1.5.8.1 DOOR ASSEMBLIES ON STAIR ENCLOSURES SHALL | | | BE PERMITTED TO BE EQUIPPED WITH HARDWARE THAT PREVENTS | | | RE-ENTRY INTO THE INTERIOR OF THE BUILDING, PROVIDED | | | THAT ALL OF THE FOLLOWING CRITERIA ARE MET: | | | (1) THERE SHALL BE NOT LESS THAN TWO LEVELS WHERE IT IS | | | POSSIBLE TO LEAVE THE STAIR ENCLOSURE TO ACCESS ANOTHER | | | EXIT. | | | (2) THERE SHALL BE NOT MORE THAN FOUR STORIES | | | INTERVENING BETWEEN STORIES WHERE IT IS POSSIBLE TO | | | LEAVE THE STAIR ENCLOSURE TO ACCESS ANOTHER EXIT. | | | (3) RE-ENTRY SHALL BE POSSIBLE ON THE TOP STORY OR | | | NEXT-TO-TOP STORY SERVED BY THE STAIR ENCLOSURE, AND | | | SUCH STORY SHALL ALLOW ACCESS TO ANOTHER EXIT. | | | (4) DOOR ASSEMBLIES ALLOWING RE-ENTRY SHALL BE | | | IDENTIFIED AS SUCH ON THE STAIR SIDE OF THE DOOR LEAF. | | | (5) DOOR ASSEMBLIES NOT ALLOWING RE-ENTRY SHALL BE | | | PROVIDED WITH A SIGN ON THE STAIR SIDE INDICATING THE | | | LOCATION OF THE NEAREST DOOR OPENING, IN EACH DIRECTION | | | OF TRAVEL, THAT ALLOWS RE-ENTRY OR EXIT. | | | | | | | | | PLEASE REVIEW AND CORRECT OR JUSTIFY. | | | | | | | | | 6) SHEET FP 201 - FIRE CODE REFERENCES REMIAN | | | INCORRECT. PLEASE REVIEW AND ENSURE COMPLIANCE WITH THE | | | CURRENT FLORIDA FIRE PREVENTION CODE, 5TH EDITION AND | | | ALL APPLICABLE CODES REFERENCES CONTAINED WITHIN IT. | | | | | | | | | PLEASE REVIEW AND CORRECT - 1, 10, 13, 14, 20, 37, 88A | | | & 101. | | | | | | | | | 7) SHEET A5 27, AO 32 & A2 01 - THE DIMENSIONS OF THE | | | EAST OUTSIDE STAIR ARE NOT INDICATED AND CAN NOT BE | | | CONFIMRED TO MEET THE EGRESS REQUIREMENTS. I WAS UNABLE | | | TO IDENTIFY ANY SHEET WITH THE DIMENSIONS. | | | | | | PLEASE CORRECT OR PROVIDE THE REFERNECED SHEET | | | | | | | | | 8) SHEET A2 51A - A FIREPLACE IS INDICATED IN THE | | | LOUNGE 2; HOWEVER, NO FUEL SOURCE OR VENTING COULD BE | | | IDENTIFIED. | | | | | | PLEASE REVIEW AND CORRECT AND/OR IDENTIFY THE SHEET. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2016-02-08 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2016-02-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2016-01-12 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2016-01-14 12:00:08 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1. SHEET 008-A0-25 - THERE IS AN INCORRECT REFERENCE TO | | | THE FIRE CODE. | | | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | | 5TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING | | | THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | | APPLICABLE CODES OR STANDARDS. | | | FIRE SPRINKLER WORK SHALL COMPLY WITH THE REQUIREMENTS | | | OF NFPA 13, 2010 EDITION. | | | FIRE ALARM WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 72, 2010 EDITION. | | | CONSTRUCTION WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 241, 2009 EDITION. | | | FIRE EXTINGUISHERS SHALL COMPLY WITH THE REQUIREMENTS | | | OF NFPA 10, 2010 EDITION. | | | ELECTRIC WORK SHALL COMPLY WITH NFPA 70, 2011 EDITION. | | | | | | 2. SHEET 027-C3-01 - THE LOCATION OF THE FIRE HYDRANTS | | | AND FDC'S IS LIMITED AND NOT CONDUCIVE TO FIRE GROUND | | | OPERATIONS.AND NOT APPROVED. | | | | | | THE FIRE LANE AROUND THE ENTIRE BUILDING IS NOT | | | REQUIRED AND CAN BE ELIMINATED. | | | | | | RELOCATION OF THE FIRE HYDRANT AND FDC ON THE NORTH | | | SIDE TO THE LANDSCAPE ISLAND AREA IN THE FRONT ON THE | | | MAIN ENTRANCE ACCESS. ON SHEET 071-L9-10 THE AREA | | | MARKED WITH TREES FD9 AND 4FD IS STRONGLY ENCOURAGED. | | | 3FT TO THE SIDE AND REAR IS REQUIRED AND, IF DESIRED, | | | THE EQUIPMENT CAN BE COLORED TO MATCH THE LANDSCAPE. | | | | | | RELOCATION OF THE SOUTHEAST FIRE HYDRANT AND FDC TO THE | | | AREA OF THE BACK FLOW PREVENTORS BEFORE THE GATE IS | | | STRONGLY ENCOURAGED. | | | | | | CLOSE COORDINATION WITH THE PREVNETION BUREAU WOULD BE | | | EXTRMELY BENEFICIAL. | | | | | | 3. SHEET 603-FP2-OP1 & OP2 - PROVIDE NOTE INDICATING | | | THAT FIRE SPRINKLER COVERAGE COMPLIES WITH THE | | | REQUIRMENTS AND DESIGN OF STACKED PARKING WHERE | | | APPLICABLE. | | | | | | 4. SHEET 603-FP2-OP1 - NO SPRINKLER PROTECTION SHOWN IN | | | CENTER CORE AREAS. COMPLETE FIRE SPRINKLER SYSTEM IS | | | REQUIRED BE NFPA 1, 101, AND 13. | | | | | | 5. SHEET 605 FP2-01 - NO SPRINKLER PROTECTION SHOWN IN | | | EMEGENCY RM. | | | | | | 6. SHEET 605 FP2-01 - NO FIRE PROTECTION SHOWN IN FPL | | | VAULT RM. | | | | | | 7. SHEET 605 FP2-01 - NO SPRINKLER PROTECTION SHOWN IN | | | EXIT CORRIDOR 114 ALONG LAUNDRY RM. | | | | | | 8. SHEET 605 FP2-01 - NO SPRINKLER PROTECTION IN TRASH | | | CHUTE ( NOT SHOWN FOR THE ENTIRE BLDG) | | | | | | 9. SHEET 606 FP2-02 - A FCVA COULD NOT BE LOCATED OR IS | | | NOT INDICATED. | | | | | | (PROVIDE A NOTE FOR EACH FCVA ON EACH FLOOR ON WHAT IT | | | SHUTS DOWN.) | | | | | | 10. SHEET 606 FP2-24 - A FCVA COULD NOT BE LOCATED OR | | | IS NOT INDICATED ON THE 18TH & 19TH LEVEL. | | | | | | 11. SHEET 608 FP2-05 - A FCVA COULD NOT BE LOCATED OR | | | IS NOT INDICATED. | | | | | | 12. SHEET 612 FP2-20 - A FCVA COULD NOT BE LOCATED AND | | | INDICATED ITS ON THE 18TH & 19TH LEVEL. | | | | | | 13. SHEET 613 FP2-21 - A FCVA COULD NOT BE LOCATED AND | | | INDICATED ITS ON THE 18TH & 19TH LEVEL. | | | | | | 14. SHEET 614 FP2-22 - A FCVA COULD NOT BE LOCATED AND | | | INDICATED ITS ON THE 18TH & 19TH LEVEL. | | | | | | 15. SHEET 615 FP2-23 - A FCVA COULD NOT BE LOCATED AND | | | INDICATED ITS ON THE 18TH & 19TH LEVEL. | | | | | | 16. SHEET 617-FP2-25 - A FCVA COULD NOT BE LOCATED AND | | | INDICATED ITS ON THE 18TH & 19TH LEVEL. | | | | | | 17. SHEET 621-FP4-03 - A REGULATING HOSE VALVE IS NOT | | | INDICATED. ( EACH FLLOR SHALL HAVE A NOTE INDICATING | | | THE PSI AND LOCATION OF A RHV PER NFPA 14) | | | | | | 18. SHEET 180-A5-26 - NO DETAIL IS PROVIDED FOR | | | INDICATED HANDRAILS, ALL HANDRAILS SHALL COMPLY WITH | | | NFPA 101. CHAPTER 7, 7.2.2.4.4.1. MIN. 34" | | | | | | 19. SHEET 181-A5-27 - NO DETAIL IS PROVIDED FOR | | | INDICATED HANDRAILS, ALL HANDRAILS SHALL COMPLY WITH | | | NFPA 101. CHAPTER 7, 7.2.2.4.4.1. MIN. 34". | | | | | | 20. SHEET 182-A5-28 - NO DETAIL IS PROVIDED FOR | | | INDICATED HANDRAILS, ALL HANDRAILS SHALL COMPLY WITH | | | NFPA 101. CHAPTER 7, 7.2.2.4.4.1. MIN. 34". | | | | | | 21. SHEET 184-A5-51 - SECTIONS 1 & 2 HANDRAILS SHALL | | | COMPLY WITH NFPA 101. CHAPTER 7, 7.2.2.4.4.1. MIN. 34". | | | | | | 22. GENRAL STAIRWAY SHEETS - STAIRWAY TREAD MARKING AND | | | HANDRAIL MARKINGS SHALL COMPLY WITH NFPA 101, CHAPTER | | | 7, 7.2.2.5.4.3, THROUGH 7.2.2.5.5.3 | | | | | | 23. SHEET 187-A5-21 - PROVIDE STAIWAY IDENTIFICATION | | | SIGNAGE IS NOT INDICATED. STAIRWAY INDENTIFICATION | | | SHALL COMPLY WITH NFPA 101, CHAPTER 7, 7.2.2.5.4. | | | | | | 24. MECHANICAL SHEETS 396 - 430 - IT IS NOT CLEARLY | | | INDICATED WHAT AREAS WILL BE SMOKE CONTROL, SMOKE EVAC, | | | STAIRWELL PRESSURIZATION OR ELEVATOR SHAFT | | | PERSSURIZATION. | | | | | | 25. ELECTRICAL SHEETS 448 - 469 = IT IS NOT CLEARLY | | | INDICATED THE LOCATION OF EXIT LIGHTING ON ANY LEVEL. | | | | | | 26. GENERAL SHEETS - IT IS NOT CLEARLY INDICATED THE | | | INITIAL OR BACK-UP POWER OF THE FIRE PUMP. | | | | | | 27. GENERAL SHEETS - IT IS NOT CLEARLY INDICATED, IF | | | ANY, THE EMERGENCY POWER TO THE EMERGENCY GENERATOR. | | | | | | 28. THE FIRE COMMAND CENTER SHALL COMPLY WITH NFPA 1, | | | CHAPTER 11, BUILDING SERVICES; 11.9 AND SHALL CONTAIN | | | THE FOLLOWING FEATURES: | | | | | | 1. SHALL BE A MINIMUM OF 200 FT SQUARED WITH A MINIMUM | | | DIMENSION OF 10 FT. | | | 2. THE FIRE DEPARTMENT COMMUNICATIONS SYSTEM. | | | 3. A TELEPHONE FOR FIRE DEPARTMENT USE WITH CONTROLLED | | | ACCESS TO THE PUBLIC TELEPHONE SYSTEM | | | 4. SCHEMATIC BUILDING PLANS INDICATING THE TYPICAL | | | FLOOR PLAN AND DETAILING THE BUILDING CORE, MEANS OF | | | EGRESS, FIRE PROTECTION SYSTEMS, FIRE-FIGHTING | | | EQUIPMENT AND FIRE DEPARTMENT ACCESS AND THE LOCATION | | | OF FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE | | | BARRIERS AND SMOKE PARTITIONS | | | 5. A WORK TABLE. | | | 6. IF APPLICABLE, A HAZARDOUS MATERIAL MANAGEMENT PLAN | | | FOR THE BUILDING. | | | 7. THE EMERGENCY VOICE/ALARM COMMUNICATION SYSTEM | | | CONTROL UNIT. | | | 8. ANNUNCIATOR UNIT VISUALLY INDICATING THE LOCATION OF | | | THE ELEVATORS AND WHETHER THEY ARE OPERATIONAL | | | 9. STATUS INDICATORS AND CONTROLS FOR AIR DISTRIBUTION | | | SYSTEMS. | | | 10. CONTROLS FOR UNLOCKING STAIRWAY DOORS | | | SIMULTANEOUSLY | | | 11. SPRINKLER VALVE AND WATER FLOW DETECTOR DISPLAY | | | PANELS | | | 12. EMERGENCY AND STANDBY POWER STATUS INDICATORS | | | 13. FIRE PUMP STATUS INDICATORS | | | 14. GENERATOR SUPERVISION DEVICES AND MANUAL START AND | | | TRANSFER FEATURES. | | | 15. PUBLIC ADDRESS SYSTEM, WHERE SPECIFICALLY REQUIRED | | | BY OTHER SECTIONS OF THIS CODE | | | 16. CONTROLS REQUIRED FOR SMOKE CONTROL | | | 17. ELEVATOR FIRE RECALL SWITCH IN ACCORDANCE WITH ASME | | | A17.1. | | | 18. ELEVATOR EMERGENCY OR STANDBY POWER SELECTOR | | | SWITCH(ES), WHERE EMERGENCY OR STANDBY POWER IS | | | PROVIDED | | | | | | 29. THE BUREAU'S APPROVAL OF THIS SUBMITTED PROJECT | | | DOES NOT CONSTITUTE IT'S FINAL REVIEW OR APPROVAL. | | | | | | 35. THE BUREAU SHALL REVIEW ALL RE-SUBMITTED BUILDING | | | PLANS AT THE APPROPRIATE TIME AND IN ACCORDANCE WITH | | | THE REQUIREMENTS OF ALL APPLICABLE CODES AND STANDARDS. | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2017-02-06 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-02-06 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-02-06 |
Time |
16:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2016-12-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-12-28 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-12-28 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2016-12-28 16:30:32 | | | | | | | 2ND REVIEW: FBC 2010 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | GAS COMMENTS:3RD REQUEST | | | | | | 6. SUBMIT CALCULATIONS FOR COMBUSTION AIR FOR EACH | | | APPLIANCE WITH CUBIC FT. REQUIRED AND WHAT IS PROVIDED | | | PER THE FBC-2010 FUEL GAS CODE SEC. 304. | | | | | | 8. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | | TERMINATION OF THE GAS VENTS PER FBC-2010 FUEL GAS CODE | | | SEC. 502 THRU 505. | | | | | | 3RD REVIEW: | | | | | | 1. BTU LOADS ON THE GAS RISER ARE SHOWN AS CFH SHOULD | | | THEY BE MBH OR BTU PLEASE CLARIFY. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 2. UNDER THE GAS CALCULATIONS THE TOTAL GAS | | | CONSUMMATION IS SHOWN AS CFH PLEASE CLARIFY. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | 3.TABLE LISTED FOR SIZING IS FOR LESS THAN 2PSI WITH A | | | PRESSURE DROP OF 0.6 IN. THE MAIN SYSTEM IS SHOWN AS | | | 2PSI PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 4. PLEASE PROVIDE A RISER DIAGRAM FOR UNIT SHOWING | | | LOCATION IF THE UNITS. PER WPB AMEND TO FBC 107.2.1 | | | | | | IN ORDER TO EXPEDITE ISSUANCE OF THIS PERMIT I SUGGEST | | | THE WE SET UP A MEETING PLEASE CONTACT ME CONTACT INFO | | | I | | | | | | | | | | | | DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND | | | THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON | | | RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS. | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2016-08-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-08-17 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-08-17 |
Time |
10:11 |
Sent To |
|
|
| Notes |
| 2016-08-17 10:38:40 | | | | | | | 2ND REVIEW: FBC 2010 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | GAS COMMENTS: 1ST REVIEW HAVE NOT COMPLIED | | | | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL | | | CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS FOR 2PSI | | | AND .5PSI SYSTEMS PER FBC-2010 FUEL GAS, SECS. 402.4.1, | | | 402.4.2. | | | | | | | | | | | | | | | | | | 4. BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD ON | | | THE SYSTEM. REFER TO THE FBC-2010 FUEL GAS SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU 402.4(37). | | | | | | | | | | | | 6. SUBMIT CALCULATIONS FOR COMBUSTION AIR FOR EACH | | | APPLIANCE WITH CUBIC FT. REQUIRED AND WHAT IS PROVIDED | | | PER THE FBC-2010 FUEL GAS CODE SEC. 304. | | | | | | | | | | | | 8. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | | TERMINATION OF THE GAS VENTS PER FBC-2010 FUEL GAS CODE | | | SEC. 502 THRU 505. | | | | | | 2ND REVIEW: | | | | | | 1. IN THE NOTE FOR GAS CALCULATIONS YOU LISTED TABLE | | | 402.4(6) IN THE FBC FUEL GAS THIS TABLE IS FOR COPPER | | | TUBING THE PLAN SHOWS SCHEDULE 40 METALLIC PLEASE | | | CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | 2. NOTE #1 PLEASE CLARIFY WHAT TYPE OF PIPING IS GOING | | | TO BE USED UNDERGROUND. METALLIC PIPING IS EXTREMELY | | | RESTRICTIVE ON USE UNDERGROUND. PER WPB AMEND TO FBC | | | 107.2.1 FBC FUEL GAS 404.9 | | | 3. SHOW REGULATORS AND DRIP LEGS.1. IN THE NOTE FOR GAS | | | CALCULATIONS YOU LISTED TABLE 402.4(6) IN THE FBC FUEL | | | GAS THIS TABLE IS FOR COPPER TUBING THE PLAN SHOWS | | | SCHEDULE 40 METALLIC PLEASE CLARIFY. PER WPB AMEND TO | | | FBC 107.2.1 | | | | | | | | | 4. BRANCH SIZE FOR TYPICAL UNIT ON GAS RISER 4 SHOWS | | | 3/4 THE REST OF THE RISERS SHOW 1/2 PLEASE CLARIFY. PER | | | WPB AMEND TO FBC 107.2.1 | | | 5. NOTE #4 PROVIDE ISOMETRIC AND FLOOR PLAN DRAWING | | | SHOWING THE VENT LOCATIONS OF THE PRESSURE REGULATORS. | | | PER WPB AMEND TO FBC 107.2.1 | | | 6. SHOW GAS LINE ON A FLOOR PLAN. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | | | | DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND | | | THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON | | | RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS. | | | | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2016-01-29 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-01-29 |
Time |
17:33 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-01-29 |
Time |
17:33 |
Sent To |
|
|
| Notes |
| 2016-01-29 17:36:06 | | | | | | | 1ST REVIEW: FBC 2014 | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | GAS COMMENTS: | | | | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL | | | CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS PER | | | FBC-2014 FUEL GAS, SECS. 402.4.1, 402.4.2. | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE EHD NUMBER OF CORRUGATED STAINLESS | | | STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. WPB | | | AMENDMENTS TO FBC SEC. 107.2.1. | | | | | | 3. TYPE OF GAS, (LP OR NATURAL). | | | | | | 4. BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD ON | | | THE SYSTEM. REFER TO THE FBC-2014 FUEL GAS SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU 402.4(37). | | | | | | 5. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, | | | (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING | | | AND/OR SYSTEM PER THE FBC-2014 FUEL GAS APPENDIX A ? | | | USE OF CAPACITY SECTION A.3.1(4) & 2014 FUEL GAS CODE | | | SEC. 402.4.1. | | | | | | 6. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | | FBC-2014 FUEL GAS CODE SEC. 304. | | | | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) PER FBC-2014 | | | FUEL GAS SEC. 402.2. IF NATURAL GAS SPECIFY .5 PSI OR 2 | | | PSI. | | | | | | 8. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | | TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE | | | SEC. 502 THRU 505. | | | | | | 9. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2017-02-10 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-02-10 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-01-24 |
Time |
14:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-01-11 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-01-11 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2016-11-23 |
Time |
08:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2016-10-20 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2016-10-20 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2016-07-26 |
Time |
14:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2016-04-13 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2016-04-13 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2016-01-07 |
Time |
08:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
P |
Date |
2017-02-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-01-30 |
Time |
10:06 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-01-30 |
Time |
10:06 |
Sent To |
|
|
| Notes |
| 2017-02-01 14:31:33 | 2/01/2017 RECEIVED AND VERIFIED PALM BEACH COUNTY | | | IMPACT FEE RECEIPT: | | | MU-2017-001622-0000 | | | TOTALFEES: $516294.03 | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | 2017-01-30 10:07:07 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2016-12-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-12-20 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-12-20 |
Time |
13:30 |
Sent To |
|
|
| Notes |
| 2016-12-20 13:30:15 | IMPACT FEES | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER PX,CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2016-08-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-08-29 |
Time |
17:13 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-08-29 |
Time |
17:13 |
Sent To |
|
|
| Notes |
| 2016-08-29 17:13:48 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2016-01-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-01-23 |
Time |
09:34 |
Rev Time |
|
| Received By |
jwitmer |
Date |
2016-01-23 |
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2016-01-23 09:54:06 | IMPACT FEES | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2017-02-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-02-07 |
Time |
12:08 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-02-03 |
Time |
13:58 |
Sent To |
|
|
| Notes |
| 2017-02-07 12:13:35 | MECHANICAL PROVISOS: | | | 2/7/17 | | | | | | 1) A REVISION TO THE APPROVED PLANS IS REQUIRED TO SHOW | | | THE MISSING FIRE OR FIRE/SMOKE DAMPERS AT THE LOCATIONS | | | LISTED BELOW. | | | | | | * M2.0P2 NORTH CORE: 4X4 O/A DUCT PENETRATION RESIDENT | | | STORAGE WALL | | | * M2.0P2 EAST: 6X4 O/A DUCT PENETRATING STORAGE ROOM | | | WALL AT EAST SIDE OF BUILDING. | | | * M2.0P1: 4X4 O/A DUCT AT WATER FEATURE WALL | | | * M2.0P1: 4X4 O/A DUCT AT MAINTENANCE WALL | | | * M2.0P1: 6X6 O/A DUCT AT RESIDENT STORAGE | | | * M2.0P1: 4X4 O/A DUCT AT CORRIDOR | | | * M2.0P1: 6' FLEX DUCT AT STORAGE P116. | | | * M2.0P1: 12X6 DUCT PENETRATING WALLS AT MEP/CAR | | | WASH/DOG SPA. | | | * M2.0P1: 12X12 EXHAUST DUCT AT DOG SPA. | | | * M2.01: INTAKE OPENING AND EXHAUST OUTLET AT GENERATOR | | | ROOM. | | | * M2.01: EXHAUST DUCT AT MANICURE ROOM WALL. | | | * M2.01: 12X6 O/A DUCT AT CORRIDOR | | | * M2.02: SOUTH CORE- 10X10 DUCT AT JANITOR/FIRE VEST. & | | | FIRE VEST./ELEV. LOBBY. | | | * M2.02: 26X12 DUCT AT MEP CLOSET. | | | * M2.02 18X10 DUCT AT YOGA ROOM.. | | | * M2.05: SOUTH CORE- 18X10 DUCT PENETRATING THE SHAFT | | | NEAR STAIR #3. | | | * M2.05: NORTH CORE- TWO DUCTS SHOWN IN STAIR #1 | | | ENCLOSURE PENETRATING STAIR ENCLOSURE/UTILITY ROOM | | | WALL. | | | * M2.17, 18, 20, 21, 22: 18X10 DUCT ATR SHAFT | | | PENETRATION. | | | * M2.22: SOUTH CORE- 50X16 O/A DUCT AND 14X6 SUPPLY | | | DUCT AT SHAFT. | | | * M2.22 NORTH CORE- 22X6 O/A DUCT AT SHAFT PENETRATION. | | | * M2.23: NORTH CORE- 22X6 O/A DUCT AT SHAFT | | | PENETRATION. | | | * M2.24: SOUTH CORE- EXHAUST DUCTS PENETRATING SHAFTS. | | | * M2.25: SOUTH CORE- 18X10 AT SHAFT. | | | * M2.26: SOUTH CORE: EXHAUST DUCT KEF #3 AT SHAFT. | | | * M2.26: NORTH CORE: OA-1 DUCT AT SHAFTI | | | | | | 2) ACCESS FOR MAINTENANCE AND REPLACEMENT OF ALL | | | MECHANICAL EQUIPMENT SHALL BE PROVIDED. SUBMIT | | | STRUCTURAL DETAILS FOR PANELS WHERE NECESSARY. | | | | | | 3) THE FOLLOWING LIST OF DEFERRED SUBMITTALS SHALL BE | | | SUBMITTED PRIOR TO FIELD INSPECTION REQUESTS: | | | | | | A) STRUCTURAL DETAILS AND WIND LOAD ENGINEERING FOR ALL | | | ROOFTOP AND EXTERIOR MECHANICAL EQUIPMENT AND | | | COMPONENTS INCLUDING THE COOLING TOWER, THE DOA UNITS, | | | THE FANS AND FAN CURBS, LOUVERS, ETC. | | | | | | B) STRUCTURAL DRAWINGS AND DETAILS FOR THE COOLING | | | TOWER ACCESS PLATFORM AND LADDER. | | | | | | C) MANUFACTURER'S SPECIFICATIONS FOR: | | | COOLING TOWER | | | GENERATOR | | | SMOKE CONTROL AND PRESSURIZATION FANS | | | BOILER AND BOILER VENTING | | | HEAT EXHANGERS | | | FLAMEBAR DUCT | | | FSD & FD DAMPERS | | | O/A MOTORIZED DAMPERS | | | CO AND NO2 DETECTORS | | | FIRESTOPPING | | | ACCESS PANELS FOR ABOVE CEILNG HP'S | | | CHILLED WATER PIPING INSULATION | | | | | | D) FLORIDA PRODUCT APPROVALS AND/OR MIAMI-DADE NOA'S | | | FOR LOUVERS AND ROOF STANDS | | | | | | 1) DEFERRED SUBMITTAL: 107.3.4.2 DEFERRED SUBMITTALS. | | | FOR THE PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS | | | ARE DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE | | | NOT SUBMITTED AT THE TIME OF THE | | | APPLICATION AND THAT ARE TO BE SUBMITTED TO THE | | | BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. DEFERRAL | | | OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR APPROVAL OF | | | THE BUILDING OFFICIAL. THE REGISTERED DESIGN | | | PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST THE | | | DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS FOR | | | REVIEW BY THE BUILDING OFFICIAL. | | | | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | 2) DEFERRED SUBMITTAL. 2010 FBC 107.3.4.1 PRODUCT | | | APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED BY THE | | | DCA RULE 9N-03 SHALL BE REVIEWED AND APPROVED IN | | | WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2017-01-30 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-01-30 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-01-27 |
Time |
10:50 |
Sent To |
|
|
| Notes |
| 2017-01-30 11:06:02 | 4TH REVIEW FBC-2014 MECHANICAL | | | PERMIT #15111020 | | | 1/27/17 | | | | | | THE FOLLOWING LIST OF COMMENTS FROM THE 3RD REVIEW | | | STILL EXIST OR HAVE NOT BEEN ADDRESSED IN ENTIRETY. | | | | | | 1) COMMENT #1: THE REVISED PLANS UPLOADED ON 1/20/2017 | | | HAVE ELECTRONIC SEALS AND SIGNATURES. ALL OTHER | | | EXISTING PLAN SHEETS DO NOT. | | | | | | 2) COMMENT #3: THE REVISED ENERGYGAUGE COMPLIANCE MUST | | | BE ELECTRONICALLY SIGNED AND SEALED. | | | | | | 3) COMMENT #5: PLAN SHEETS M2.0P1, M2.0P2, & M6.02 HAVE | | | NOT BEEN REVISED PER THE COMMENTS OR NARRATIVE | | | RESPONSE. | | | | | | 4) COMMENT #8, M2.0P1: REQUESTED SEPARATION DISTANCE | | | BETWEEN THE GENERATOR AIR INTAKE AND EXHAUST NOT | | | PROVIDED. | | | | | | 5) COMMENT #9, M2.0P1: REQUESTED MOTORIZED DAMPERS FOR | | | O/A DUCTS TO GUESTROOMS. | | | | | | 6) COMMENT #11, M6.02: FAN SCHEDULE NOTES NOT UPDATED. | | | | | | 7) COMMENT #12, M5.04: PRINT ON PLAN SHEET STILL FAINT | | | AND ILLEGIBLE. | | | | | | 8) COMMENT #13, M6.02: SCHEDULE NOT UPDATED TO PROVIDE | | | CORRECT NOTES AND NOA #S. | | | | | | 9) COMMENT #14, M2.0P1: PLAN NOT REVISED TO SHOW | | | RELOCATION OF GARAGE EXHAUST FANS OVER STAIRWELL AS | | | STATED IN THE RESPONSE NARRATIVE. | | | | | | 10) COMMENT #17, M2.01: REQUESTED COMBUSTION AIR | | | CALCULATIONS NOT PROVIDED. | | | | | | 11) COMMENT #18, M2.01: REQUESTED AIR BALANCE | | | CALCULATIONS NOT PROVIDED. | | | | | | 12) COMMENT #21, M2.01: REQUESTED DEMAND CONTROLLED | | | VENTILATION NOT SHOWN IN THE CLUB DINING ROOM. | | | | | | 13) COMMENT #23, M2.02: ABOVE CEILING PLENUM SPACES NOT | | | IDENTIFIED CLEARLY. | | | | | | 14) COMMENT #25, M2.23: REQUESTED DUCTWORK NOT SHOWN. | | | | | | 15) BELOW IS A LIST OF MISSING FIRE OR FIRE/SMOKE | | | DAMPERS FOR DUCTS PENETRATING RATED WALLS. PLEASE | | | PROVIDE THE DAMPERS FOR DUCTS WHERE REQUIRED, OR IF | | | CLAIMING ANY EXCEPTIONS WRITTEN IN THE CODE, PLEASE | | | PROVIDE THE SECTION NUMBER. | | | | | | * M2.0P2 NORTH CORE: 4X4 O/A DUCT PENETRATION RESIDENT | | | STORAGE WALL | | | * M2.0P2 EAST: 6X4 O/A DUCT PENETRATING STORAGE ROOM | | | WALL AT EAST SIDE OF BUILDING. | | | * M2.0P1: 4X4 O/A DUCT AT WATER FEATURE WALL | | | * M2.0P1: 4X4 O/A DUCT AT MAINTENANCE WALL | | | * M2.0P1: 6X6 O/A DUCT AT RESIDENT STORAGE | | | * M2.0P1: 4X4 O/A DUCT AT CORRIDOR | | | * M2.0P1: 6" FLEX DUCT AT STORAGE P116. | | | * M2.0P1: 12X6 DUCT PENETRATING WALLS AT MEP/CAR | | | WASH/DOG SPA. | | | * M2.0P1: 12X12 EXHAUST DUCT AT DOG SPA. | | | * M2.01: INTAKE OPENING AND EXHAUST OUTLET AT GENERATOR | | | ROOM. | | | * M2.01: EXHAUST DUCT AT MANICURE ROOM WALL. | | | * M2.01: 8X6 O/A DUCT AT CORRIDOR | | | * M2.02: 10X10 DUCT AT JANITOR/FIRE VEST. & FIRE | | | VEST./ELEV. LOBBY. | | | * M2.02: 26X12 DUCT AT MEP CLOSET. | | | * M2.02 18X10 DUCT AT YOGA ROOM. | | | * M2.03: TRANSFER DUCT AT CORRIDOR BY GUEST SUITE 11. | | | PLEASE NOTE THAT THE CORRIDOR CANNOT BE USED AS A | | | SUPPLY, RETURN, EXHAUST, RELIEF, OR AS A VENTILATION | | | AIR DUCTS. SECTION 601.2. | | | * M2.03: DUCTS PENETRATING RATED SHAFTS BY RESTROOMS IN | | | GUEST SUITES 9, 10, & 11. | | | * M2.05: SOUTH CORE- 18X10 DUCT IN STAIR #3 ENCLOSURE | | | NOT PERMITTED AND NOT DAMPERED. | | | * M2.05: NORTH CORE- TWO DUCTS SHOWN IN STAIR #1 | | | ENCLOSURE /UTILITY NOT PERMITTED/NOT DAMPERED. | | | * M2.17, 18, 20, 21, 22: DUCTS NOT PERMITTED OR | | | DAMPERED IN STAIR #3 ENCLOSURE. | | | * M2.22: SOUTH CORE- 50X16 O/A DUCT AND 14X6 SUPPLY | | | DUCT AT SHAFT. | | | * M2.22 NORTH CORE- 16X8 AT SHAFT. | | | * M2.23: NORTH CORE- NO DUCTS SHOWN IN DRAWING. | | | * M2.24: SOUTH CORE- EXHAUST DUCTS PENETRATING SHAFTS. | | | * M2.25: SOUTH CORE- 18X10 AT SHAFT. | | | * M2.25: NORTH CORE: NO SIZE OR DAMPER FOR DUCT AT | | | FIREMAN'S VEST./CORRIDOR WALL. | | | * M2.26: SOUTH CORE: EXHAUST DUCT KEF #3 AT SHAFT. | | | * M2.26: NORTH CORE: OA-1 DUCT AT SHAFT. | | | | | | 16) IN ORDER TO EXPEDITE THE REVIEW OF THE SUBMITTED AC | | | CALCULATIONS FOR THE APARTMENTS, PLEASE LABEL THE | | | APARTMENT NUMBERS AND ZONES ON THE ENLARGED MECHANICAL | | | FLOOR PLANS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2016-12-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-12-21 |
Time |
17:47 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-12-20 |
Time |
11:31 |
Sent To |
|
|
| Notes |
| 2016-12-21 17:48:24 | 3RD REVIEW FBC-2014 MECHANICAL | | | PERMIT #15111020 | | | 12/20/16 | | | | | | 1) ALL SUBMITTED ENGINEERED MECHANICAL PLANS, | | | DOCUMENTS, AND CALCULATIONS SHALL BEAR THE ELECTRONIC | | | SEAL AND SIGNATURE OF THE ENGINEER OF RECORD- SECTION | | | 471.025 F.S. AND SECTION 61G15-23.005 FLORIDA | | | ADMINISTRATIVE CODE. CURRENTLY NONE OF THE UPLOADED | | | PLANS, DOCUMENTS, OR CALCULATIONS ARE IN COMPLIANCE. | | | | | | 2) THE FOLLOWING SHEETS DO NOT BEAR THE TITLE BLOCK OF | | | THE APPARENT ENGINEER OF RECORD- EDWARDS & ZUCK: SHEETS | | | M2.54E, M2.54F, M4.01- M4.05, & M5.01- M5.03, & M6.01. | | | | | | 3) 3RD REQUEST FOR THE ENERGYGAUGE SUBMITTAL TO BE | | | CORRECTED TO MATCH THE EQUIPMENT SCHEDULES- 3RD REQUEST | | | TO COMPLY. REFER BACK TO 1ST REVIEW COMMENT #1 | | | | | | 4) 3RD REQUEST FOR AC COOLING AND HEATING CALCULATIONS. | | | REFER BACK TO 1ST REVIEW COMMENT #2 | | | | | | 5) SHEET M2.0P1 & M2.0P2: PLACE A NOTE ON THE PLANS | | | REFERENCING SHEET M5-07 FOR CONTROLS OPERATIONS FOR THE | | | GARAGE EXHAUST FANS. REVISE THE NOTES ON M5-07 TO SHOW | | | A CONTINUOUS MINIMUM EXHAUST RATE OF .05 CFM PER | | | SQ.FT.- SECTION 404.2 | | | | | | 6) M2.0P1 & M6.02: THE NOTES IN THE FAN SCHEDULE | | | INDICATE THE GARAGE EXHAUST FANS ARE NOT HIGH WIND | | | RATED. | | | | | | 7) M2.0P2 & M6.02: PGEF-P2- 1C & 1D LISTED IN THE | | | EXHAUST CALCULATIONS ARE NOT IN THE SCHEDULE. | | | PGEF-P2-1A & 1B DO NOT HAVE LARGE ENOUGH CAPACITY TO | | | EXHAUST THE REQUIRED 38,790 CFMS OF EXHAUST. | | | | | | 8) M2.01: VERIFY WITH NOTES ON MEASUREMENTS THE | | | SEPARATION DISTANCES BETWEEN THE GENERATOR AND TANK | | | ROOM EXHAUST OUTLETS AND THE GENERATOR ROOM AIR INTAKE | | | LOUVER. THE ELEVATION DRAWING APPEARS TO INDICATE | | | NON-COMPLIANCE- SEE SHEET A3.35. | | | | | | 9) M2.01: IT APPEARS THAT THE DRYER AND IRONER EXHAUST | | | DUCTS ARE RUNNING THROUGH AN ABOVE CEILING PLENUM WHICH | | | IS PROHIBITED PER SECTION 504.4. PLEASE CLEARLY | | | DESIGNATE THE LOCATIONS OF ABOVE CEILING PLENUMS. | | | | | | 10) M2.01: IT APPEARS MOTORIZED DAMPERS ARE MISSING FOR | | | THE O/A SUPPLY TO THE GUESTROOMS. | | | | | | 11) M5.04 & M6.02: REFER TO THE SUMMARY TABLE ON PAGE | | | 26 OF THE SMOKE CONTROL RATIONAL ANALYSIS. THE | | | LOCATIONS OF THE STAIRWELL PRESSURIZATIONS FANS AND FAN | | | CAPACITIES SPECIFIED IN THE UPDATED REPORT DIFFER FROM | | | THE SPECIFICATIONS IN THE DRAWINGS AND THE SCHEDULE. A) | | | THE NOTES IN THE SCHEDULE INDICATE THE STAIRWELL AND | | | ELEVATOR PRESSURIZATION FANS ARE NOT HIGH-WIND RATED, | | | AND NOT UL LISTED FOR SMOKE CONTROL. | | | | | | 12) M5.04: ALL OF THE PRINTED NOTES AND LABELS ON THE | | | PLAN ARE BARELY LEGIBLE AND NEED TO BE EMBOLDENED. THE | | | LETTERS "N.C." ARE SHOWN AT EACH HORIZONTAL SHAFT | | | OPENING. PLEASE CLARIFY WHAT THOSE LETTERS STAND FOR. | | | | | | 13) M6.02 FAN SCHEDULE: THE NOTES IN THE REMARKS COLUMN | | | ARE CONFUSING FOR THE TEF'S AND THE KEF'S. SOME OF THE | | | TEF'S ON THE ROOF HAVE NOAS AND SOME DON'T. AND HOW CAN | | | A TEF AND A KEF HAVE THE SAME NOA NUMBER? PLEASE NOTE | | | NOA#14-0325-06 LISTED IN THE NOTES WAS NOT FOUND ON THE | | | MIAMI-DADE PRODUCT CONTROL WEBSITE. | | | | | | 14) A5.28: THE GARAGE EXHAUST FAN OUTLETS CANNOT BE | | | LOCATED OVER STAIRWELL #9 PLATFORM AND STAIRS- SEE | | | SECTIONS 501.3, 501.3.1(10) & 501.3.1.1. | | | | | | 15) M5.05 & M5.06: PLEASE CIRCLE OR HIGHLIGHT THE | | | LOCATION OF OAU-3 IN THE CONDENSER WATER RISER DRAWING. | | | | | | 16) M2.01: IN REFERENCE TO COMMENT #28 FROM THE 2ND | | | REVIEW, THE PLAN STILL APPEARS TO INDICATE HP-1L-5 AND | | | HP-1L-6 ARE SHARING A COMMON PLENUM WHICH WOULD REQUIRE | | | A SMOKE DETECTOR. I AM NOT SEEING A DUCTED RETURN FROM | | | THE CONFERENCE ROOM AS STATED IN THE NARRATIVE. | | | | | | 17) M2.01: COMMENT #29 FROM THE 2ND REVIEW STILL | | | EXISTS: PROVIDE COMBUSTION AIR CALCULATIONS FOR THE | | | DRYERS AND IRONER- SEE SECTION 304 FBC-14 FUEL GAS. A) | | | SEE PREVIOUS COMMENT #9. | | | | | | 18) M2.01: PROVIDE AIR BALANCE CALCULATIONS FOR THE | | | LAUNDRY AND MANICURE ROOMS. | | | | | | 19) M2.01: TELECOM HP NOT LABELED AS REQUESTED. | | | | | | 20) M2.01: COMMENT #35 FROM THE 2ND REVIEW STILL | | | EXISTS- PLEASE COMPLY. | | | | | | 21) M2.01: DEMAND CONTROLLED VENTILATION IS REQUIRED | | | FOR THE CLUB DINING ROOM- SECTION 503.2.1 FBC-10 ENERGY | | | CONSERVATION. INDICATE A MEANS ON THE PLANS. | | | | | | 22) M2.02: AS PREVIOUSLY REQUESTED LABEL THE EXHAUST | | | FANS IN THE WOMEN'S AMENITY AREA. | | | | | | 23) M2.02: PLEASE CLEARLY DESIGNATE ON THE PLAN THE | | | LOCATIONS OF ALL ABOVE CEILING PLENUM SPACES. | | | | | | 24) M2.02 & A6.87: REFER TO SECTION 602.2 & 606.2.1 AND | | | VERIFY THE LIGHT COVES BEING USED AS RETURN GRILLS ARE | | | IN COMPLIANCE. | | | | | | 25) M2.03 AND ALL OTHER PLAN SHEETS SHOWING CHILLED | | | WATER PIPING: IDENTIFY ALL HP UNITS BEING SERVICED BY | | | THE PIPING ON EACH FLOOR. | | | | | | 26) M2.23: THE DUCTWORK IS NOT SHOWN IN THE NORTH CORE. | | | | | | 27) M2.5B: PROVIDE A NOTE OR DETAIL SHOWING THE 2HR. | | | RATED SOFFIT ENCLOSING THE RETURN DUCT IN THE NORTH | | | STAIR TOWER, AND PROVIDE FS DAMPERS AT RATED WALL | | | PENETRATIONS. | | | | | | 28) BASED ON THE RESPPONSES TO THE COMMENTS THERE WILL | | | BE MANY DEFERRED SUBMITTALS FOR THE PROPOSED PROJECT. | | | PLESASE REVIEW THE FOLLWOING SECTIONS FROM THE WPB | | | AMENDMENTS TO THE FLORIDA BUILDING CODE. | | | | | | 1) DEFERRED SUBMITTAL: 107.3.4.2 DEFERRED SUBMITTALS. | | | FOR THE PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS | | | ARE DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE | | | NOT SUBMITTED AT THE TIME OF THE | | | APPLICATION AND THAT ARE TO BE SUBMITTED TO THE | | | BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. DEFERRAL | | | OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR APPROVAL OF | | | THE BUILDING OFFICIAL. THE REGISTERED DESIGN | | | PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST THE | | | DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS FOR | | | REVIEW BY THE BUILDING OFFICIAL. | | | | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | 2) DEFERRED SUBMITTAL. 2010 FBC 107.3.4.1 PRODUCT | | | APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED BY THE | | | DCA RULE 9N-03 SHALL BE REVIEWED AND APPROVED IN | | | WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. | | | | | | THE CURRENT LIST OF DEFERRED SUBMITTALS BASED ON | | | COMMENT RESPONSES ARE: | | | A) STRUCTURAL DETAILS AND WIND LOAD ENGINEERING FOR ALL | | | ROOFTOP AND EXTERIOR MECHANICAL EQUIPMENT AND | | | COMPONENTS INCLUDUNG THE COOLING TOWER, THE DOA UNITS, | | | THE FANS AND FAN CURBS, LOUVERS, ETC. | | | B) STRUCTURAL DRAWINGS AND DETAILS FOR THE COOLING | | | TOWER ACCESS PLATFORM AND LADDER. | | | C) MANUFACTURER'S SPECIFICATIONS FOR THE COOLING TOWER, | | | CHILLED WATER PIPING INSULATION, SMOKE CONTROL AND | | | PRESSURIZATION FANS, BOILER AND BOILER VENTING, THE | | | HEAT EXHANGERS, FLAMEBAR DUCT, FS DAMPERS, O/A | | | MOTORIZED DAMPERS, CO DETECTORS, AND FIRESTOPPING | | | SEALERS AND CAULKS. | | | D) ACCESS PANELS FOR ABOVE CEILNG HP'S | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2016-08-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-08-19 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-08-11 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2016-08-19 16:03:50 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #15111020 | | | 8/8/16 | | | | | | THIS SECOND REVIEW OF THE PLANS WILL REFERENCE COMMENTS | | | FROM THE 1ST REVIEW THAT EITHER STILL EXIST, OR HAVE | | | BEEN PARTIALLY RESOLVED. PLEASE NOTE THAT A | | | PRE-SUBMITTAL MEETING WAS HELD ON JUNE 20TH MEETING | | | HERE AT THE WPB BUILDING DEPARTMENT WHICH I ATTENDED. | | | AT THAT MEETING THE DESIGN TEAM FOR THE PROJECT | | | REVIEWED THE 1ST REVIEW MECHANICAL COMMENTS IN ENTIRETY | | | AND CONCLUDED THAT ALL ISSUES WOULD BE RESOLVED ON THE | | | SECOND SUBMITTAL. | | | | | | | | | 1 ) COMMENT #1 INCLUDING SUB-COMMENTS 1-A THROUGH 1-I | | | STILL EXIST. ALTHOUGH THE NARRATIVE RESPONSE STATES | | | THAT THESE ISSUES HAVE BEEN ADDRESSED, THE CORRECTED | | | DOCUMENTS AND PLANS WERE NOT SUBMITTED. | | | | | | 2) COMMENT # 2A STILL EXISTS. PROVIDE THE AC COOLING | | | AND HEATING CALCULATIONS FOR THE SYSTEMS. COMMENT #2B | | | HAS BEEN PARTIALLY ADDRESSED BUT MANY OF THE REQUESTED | | | VENTILATION CALCULATIONS HAVE NOT BEEN PROVIDED- SEE | | | ADDITIONAL COMMENTS BELOW. | | | | | | 3) COMMENT #2C, SHEET M2.0P1: THE REQUESTED EXHAUST | | | VENTILATION CALCULATIONS FOR THE P1 PARKING GARAGE | | | LEVEL HAVE NOT BEEN PROVIDED. PLEASE CLARIFY HOW MAKEUP | | | AIR FOR P1 EXHAUST IS BEING PROVIDED- THE RESPONSE | | | NARRATIVE FROM THE DESIGN PROFESSIONALS STATE THAT THE | | | PGSF- 1A & 1B SHOWN AT LEVEL P1 ARE MAKEUP AIR FANS FOR | | | LEVEL P2 EXHAUST. | | | 3A) EXHAUST VENTILATION CALCULATIONS FOR THE DOG SPA | | | NOT PROVIDED. PLEASE SUBMIT SPECS FOR THE PET DRYER IN | | | THE SPA AND PROVIDE EXHAUST DUCT DETAILS (IF | | | APPLICABLE). | | | | | | 4) MANY OF THE EXHAUST FANS SHOWN ON THE PLANS DO NOT | | | HAVE EQUIPMENT SCHEDULES. PLEASE PROVIDE SCHEDULES FOR | | | EF-P1-1, EF-P2-2, EF-P2-3, PEEF-1, PEEF-2, PEEF-3, | | | PESF-1, PGEF-P1-E, PGEF-P2-C, AND ANY OTHERS NOT | | | CURRENTLY SHOWN IN THE SCHEDULES. | | | | | | 5) COMMENT #2 D, SHEET M2.01: THE EXHAUST CALCULATIONS | | | FOR THE GENERATOR AND TANK ROOMS ARE NOT IN COMPLIANCE | | | WITH TABLE 403.3 (NOTE 1). PLEASE INDICATE WHICH CODE | | | STANDARD WAS USED TO ESTABLISH THE EXHAUST OR ACH | | | RATES. | | | | | | 6) COMMENT #2B, SHEET M2.01: THE GUEST SUITE ID NUMBERS | | | IN THE O/A SCHEDULE DO NOT MATCH THE SUITE NUMBERS ON | | | THE PLANS. CALCULATIONS NOT PROVIDED FOR CLUB DINING, | | | SERVICE PANTRY, LOBBY LOUNGE, LOUNGE 2, ENTRY LOBBY, | | | ELEVATOR LOBBIES, MAIL AND STORAGE ROOMS- PLEASE COMPLY | | | AS PREVIOUSLY REQUESTED. | | | | | | 7) COMMENT #3 INCLUDING 3A, B, & C STILL EXIST. THE | | | INCONSISTENCIES AND CONFLICTS BETWEEN THE MECHANICAL | | | PLANS, AND SPECIFICATIONS, AND THE SMOKE CONTROL | | | RATIONAL ANALYSIS HAVE NOT BEEN ADDRESSED AND | | | CORRECTED. PLEASE COMPLY. SHEET M5.04: NOTE THE AIR | | | FLOW DIRECTIONAL ARROWS FOR OAU-1 & 2 ARE POINTING IN | | | THE OPPOSITE DIRECTION OF THE FLOW. | | | | | | 8) COMMENT #3D STILL EXISTS AND IS REPRINTED HERE: D) | | | SHEETS M2.26, M2.27, M5.05, M-602: THE FOLLOWING LIST | | | OF PRESSURIZATION AND SMOKE CONTROL FANS ARE SHOWN IN | | | THE SCHEDULE AND RISER BUT NOT SHOWN ON THE 26TH LEVEL | | | OR ROOF LEVEL MECHANICAL PLANS: SPF-2, SPF-3, EPF-2, | | | EPF-4, AND SEF-1. PLEASE SHOW THE LOCATIONS OF THE FANS | | | ON THE ROOF PLANS AND PROVIDE CLEARANCE DISTANCE | | | MEASUREMENTS FOR ALL INLETS TO MECHANICAL AND GRAVITY | | | EXHAUST OUTLETS. REFER TO SECTION 708.14.2.1 FBC-10 | | | BUILDING FOR PRESSURIZATION INLET MINIMUM CLEARANCE | | | DISTANCES TO EXHAUST OUTLETS. | | | 9) COMMENT #5 STILL EXISTS. PLEASE PROVIDE THE | | | REQUESTED EQUIPMENT SCHEDULES FOR THE TOILET AND | | | KITCHEN EXHAUST FANS. | | | | | | 10) COMMENT # 8 STILL EXISTS, SEE DETAIL 2 ON SHEET | | | A3.35: IT APPEARS THAT THE OUTLETS FOR THE GARAGE | | | EXHAUST FANS PGEF-P2-1A & 1B ARE DIRECTLY OVER STAIR | | | #9. | | | 10 A) SHEETS A3.31- A3.37: PLEASE IDENTIFY AND LABEL | | | THE LOCATIONS OF ALL EXHAUST OUTLETS AND AIR INTAKE | | | OPENINGS ON LEVELS P1, P2, 1, 2 & 3 AND PROVIDE NOTES | | | AND DIMENSIONS ON THE PLANS TO VERIFY COMPLIANCE WITH | | | CLEARANCE DISTANCE REQUIREMENTS. | | | | | | 11 COMMENT #9 HAS AN INCOMPLETE RESPONSE. THE FIRE | | | RATED ASSEMBLIES ON SHEET A8.31 ARE THE FIGURES | | | ASSOCIATED WITH THE ASSEMBLIES, HOWEVER THE PRINTED | | | NOTES AND SPECIFICATIONS FOR EACH ASSEMBLY WERE NOT | | | INCLUDED. | | | | | | 12) COMMENT #11D STILL EXISTS. AS PREVIOUSLY PLEASE | | | SHOW THE LOCATIONS OF THE NITROGEN DIOXIDE DETECTORS ON | | | THE PARKING LEVELS. | | | | | | 13) COMMENT #11E STILL EXISTS. THE RESPONSE NARRATIVE | | | STATES THAT THE REQUESTED FLAMEBAR SPECIFICATIONS AND | | | DRAWINGS ARE FOUND ON SHEET M4.07, HOWEVER THAT PLAN | | | SHEET WAS NOT INCLUDED IN THE UPLOADED PLAN SETS. | | | | | | 14) COMMENTS #11G, 11H, 11I, 11J, 11K, 11L, 11M, 11O, | | | 11Q, & 11P, 11Q, 11R, 11S, 11T, & 11V STILL EXIST: | | | REFER BACK TO 1ST REVIEW COMMENTS AND CORRECT THE PLANS | | | ACCORDINGLY. | | | | | | 15) COMMENT #12A: REQUESTED EVIDENCE OF FLOOD PROOF | | | CONSTRUCTION TO PROTECT MECHANICAL EQUIPMENT NOT | | | PROVIDED. THE COMMENT FROM THE 1ST REVIEW IS REPRINTED | | | HERE: | | | A) SHEET M2.0P2: REFER TO SECTION 301.16 AND PROVIDE | | | EVIDENCE TO INDICATE COMPLIANCE FOR MECHANICAL | | | EQUIPMENT LOCATED IN A FLOOD HAZARD AREA. SOME OF THE | | | EQUIPMENT INCLUDED ARE THE HEAT PUMPS, THE FANS, THE | | | DAMPERS, THE DUCTWORK, THE DETECTORS, THE LOUVERS ETC. | | | 301.16 FLOOD HAZARD. | | | FOR STRUCTURES LOCATED IN FLOOD HAZARD AREAS, | | | MECHANICAL SYSTEMS, EQUIPMENT AND APPLIANCES SHALL BE | | | LOCATED AT OR ABOVE THE ELEVATION REQUIRED BY SECTION | | | 1612 OF THE FLORIDA BUILDING CODE, BUILDING FOR | | | UTILITIES AND ATTENDANT EQUIPMENT. | | | EXCEPTION: MECHANICAL SYSTEMS, EQUIPMENT AND APPLIANCES | | | ARE PERMITTED TO BE LOCATED BELOW THE ELEVATION | | | REQUIRED BY SECTION 1612 OF THE OF THE FLORIDA BUILDING | | | CODE, BUILDING FOR UTILITIES AND ATTENDANT EQUIPMENT | | | PROVIDED THAT THEY ARE DESIGNED AND INSTALLED TO | | | PREVENT WATER FROM ENTERING OR ACCUMULATING WITHIN THE | | | COMPONENTS AND TO RESIST HYDROSTATIC AND HYDRODYNAMIC | | | LOADS AND STRESSES, INCLUDING THE EFFECTS OF BUOYANCY, | | | DURING THE OCCURRENCE OF FLOODING UP TO SUCH ELEVATION. | | | | | | 16) COMMENT #12D, 12F, 12G, 12H STILL EXIST. REFER BACK | | | TO 1ST REVIEW COMMENTS AND CORRECT THE PLANS | | | ACCORDINGLY. | | | | | | 17) COMMENT #12I STILL EXISTS: THE REQUESTED LOUVER | | | IDENTIFICATIONS AND CLEARANCES NOT SHOWN AS INDICATED | | | IN THE RESPONSE NARRATIVE. | | | 18) COMMENT #12J STILL EXISTS: DUCT FIRESTOPPING DETAIL | | | AT MEMBRANE PENETRATION NOT PROVIDED. PLEASE NOTE THAT | | | THE FLAMEBAR INSTALLATION DETAILS AND FIRESTOPPING | | | ASSEMBLIES HAVE NOT BEEN SUBMITTED. | | | | | | 19) COMMENT #12K STILL EXISTS: FAN SCHEDULE AND | | | CLEARANCE HEIGHTS FOR THE GARAGE CIRCULATION FANS NOT | | | PROVIDED. | | | | | | 20) COMMENT #12L STILL EXISTS: DUCT CLEARANCE HEIGHTS | | | IN THE PARKING GARAGES NOT PROVIDED. | | | | | | 21) COMMENTS #12N & 12O STILL EXIST: NO CORRECTIONS OR | | | UPDATES TO THE PLAN SHEETS HAVE BEEN MADE IN REGARD TO | | | THESE COMMENTS. | | | | | | 22 ) COMMENT #13B: THE NOTE REGARDING TRANSFER TIME | | | FULL STANDBY POWER FOR THE GENERATOR HAS NOT BEEN ADDED | | | TO THE RATIONAL ANALYSIS AS INDICATED IN THE NARRATIVE. | | | PLEASE INDICATE ON WHICH ELECTRICAL PAGE THE EQUIPMENT | | | SCHEDULE FOR THE GENERATOR CAN BE FOUND, AND AS | | | PREVIOUSLY REQUESTED, PROVIDE THE MANUFACTURER?S | | | SPECIFICATIONS FOR THE GENERATOR AND FUEL TANK. | | | | | | 23) COMMENTS 13C, 13D, & 13E: SEE SHEET A3.36 (AS | | | INDICATED IN THE RESPONSE NARRATIVE) AND LABEL THE | | | GENERATOR AND TANK ROOM AIR INLETS AND EXHAUST OUTLETS. | | | | | | 24) COMMENT #13F STILL EXISTS: THE RESPONSE NARRATIVE | | | STATES "SEE PLUMBING DRAWINGS". PLEASE INDICATE WHICH | | | PLUMBING PLAN SHEET THE PIPING DIAGRAMS AND | | | SPECIFICATIONS FOR THE GENERATOR AND FUEL TANK CAN BE | | | FOUND. | | | | | | 25) COMMENTS #13G, 13H, & 13I STILL EXIST: AS STATED IN | | | THE NARRATIVE PLEASE SHOW AND LABEL THE LOCATIONS OF | | | THE AIR INLETS AND EXHAUST OUTLETS IN QUESTION- REFER | | | TO 1ST REVIEW COMMENTS. | | | | | | 26) COMMENT #13J1 STILL EXISTS: SOME OF THE REQUESTED | | | DETAILS AND PLAN VIEWS OF THE MANICURE AND PEDICURE | | | EXHAUST SYSTEMS WERE FOUND ON SHEET M4.06. PLEASE ADD | | | THIS INFORMATION TO THE DRAWINGS: A) TYPE OF EXHAUST | | | DUCTWORK. B) SEQUENCE OF OPERATION FOR THE EXHAUST | | | SYSTEM. | | | | | | 27) COMMENT #13J2 STILL EXISTS: NAIL SALON EXHAUST FAN | | | EQUIPMENT SCHEDULE NOT PROVIDED. | | | | | | 28 ) COMMENT #13J3 STILL EXISTS: RECIRCULATION OF AIR | | | FROM THE HAIR DRESSING AND NAIL SALON TO THE CONFERENCE | | | ROOM IS PROHIBITED- HP-1L-5 & HP-1L6 ARE SHARING A | | | COMMON PLENUM. THE REQUIRED SMOKE DETECTOR HAS NOT BEEN | | | PROVIDED AND SHOWN IN THE PLENUM. | | | | | | 29) SHEET M2.01: THE 8 IN. FLEX DUCTS IN THE SALON | | | SUPPLYING 400 CFMS OF AIR ARE UNDERSIZED. PLEASE REVIEW | | | ALL FLEX DUCT SIZES FOR COMPLIANCE WITH ASHRAE SIZING | | | STANDARDS. | | | | | | 30) COMMENTS #13K1-7 STILL EXIST. SHEET M2.01: THE FIRE | | | DAMPER SYMBOL AT THE SHAFT WAS NOT PLACED ON THE PLAN. | | | M4.06: THE INFORMATION PROVIDED IN THE NARRATIVE | | | RESPONSE SHOULD BE ADDED TO THE EXHAUST DETAILS. SEE | | | SECTION 504.8 FOR ADDITIONAL COMPLIANCES AND REVISE THE | | | DETAIL TO INDICATE COMPLIANCE FPR: GAUGE OF EXHAUST | | | DUCT STEEL, LOCATION OF THE EXHAUST FAN MOTOR | | | (EF-GL-1), CONTINUOUS EXHAUST OPERATION AND CONNECTION | | | TO STANDBY POWER, LINKAGE TO MAKEUP AIR SOURCE, | | | LOCATION AND DETAILS FOR REQUIRED CLEANOUT. | | | | | | 31) SHEET M4.06: A B-VENT IS SHOWN FOR THE IRONER | | | EXHAUST. CLARIFY IF THE IRONER AND DRYERS ARE GAS-FIRED | | | AND PROVIDE COMBUSTION AIR CALCULATIONS, AND INDICATE | | | HOW THE COMBUSTION AIR IS TO BE PROVIDED IF APPLICABLE- | | | SEE SECTION 304 FBC-10 FUEL GAS. REFER TO TABLE | | | 504.2(1) AND PROVIDE COMPLETE VENTING DIAGRAMS, AND AS | | | PREVIOUSLY REQUESTED, PROVIDE MANUFACTURER?S | | | SPECIFICATIONS FOR THE APPLIANCES, INCLUDING | | | MANUFACTURER?S GUIDELINES FOR VENTING. | | | | | | 32) COMMENT 13L STILL EXISTS: EXHAUST SYSTEM FOR THE | | | SOUTH CORE TRASH ROOM NOT PROVIDED. A) THERE IS A | | | MISSING FIRE DAMPERS FOR THE 10"X6" DUCT PENETRATING | | | THE FIRE-RATED TRASH/STORAGE ROOM WALL. | | | | | | 33) COMMENT #13N STILL EXISTS: LABEL THE HEAT PUMPS IN | | | THE PACKAGE ROOM AND THE TEL/ELEC ROOMS AND INCLUDE | | | THEM IN THE SCHEDULES. MECHANICAL CLOSET AND PLENUM | | | DETAILS NOT PROVIDED AS REQUESTED. | | | | | | 34) COMMENT #13O STILL EXISTS- REFER TO 1ST REVIEW | | | COMMENT. | | | | | | 35 ) COMMENTS #13Q, 13R, & 13S STILL EXIST- REFER TO | | | 1ST REVIEW COMMENTS. PLEASE NOTE: IN REGARD TO 13R, | | | ACCESS PANELS SHALL BE PROVIDED FOR ALL MECHANICAL | | | EQUIPMENT AND APPLIANCES THAT ARE LOCATED ABOVE HARD | | | CEILINGS. REVISE THE PLANS TO SHOW THE LOCATIONS OF | | | REQUIRED PANELS AND PROVIDE ARCHITECTURAL AND | | | INSTALLATION DETAILS. | | | | | | 36) COMMENT #13T, SHEET M2.01: IT APPEARS THAT O/A IS | | | NOW BEING PROVIDED MECHANICALLY TO THE GUEST SUITES, | | | HOWEVER THE NARRATIVE IS STATING THAT NATURAL | | | VENTILATION WILL BE PROVIDED THROUGH OPERABLE OPENINGS- | | | SEE MECHANICAL DRAWINGS. | | | | | | 37) COMMENT #13U, SHEET M2.01: THE RESPONSE NARRATIVE | | | INDICATES ACCESS FOR MAINTENANCE OF THE HP-1 UNITS IN | | | THE GUEST SUITES WILL BE THROUGH THE RETURN GRILLS. | | | PROVIDE THE DIMENSIONS OF THE GRILLS AND VERIFY THEY | | | WILL BE SIZED LARGE ENOUGH TO REPLACE THE UNITS- SEE | | | SECTION 306.1. AS PREVIOUSLY REQUESTED IN THE 1ST | | | REVIEW, PROVIDE AN ENLARGED DETAIL OF THE HP CLOSET. | | | | | | 38) COMMENT #14A STILL EXISTS: LABEL THE AIR INTAKE AND | | | EXHAUST OUTLET OPENINGS ON THE ARCHITECTURAL | | | ELEVATIONS. | | | | | | 39) COMMENT #14H STILL EXISTS: PROVIDE AN EXHAUST | | | SYSTEM FOR THE TRASH ROOM AND THE JANITOR'S CLOSET- | | | TABLE 6-4 ASHRAE 62.1-2007. | | | | | | 40) COMMENT #14K STILL EXISTS: FIRE DAMPERS ARE MISSING | | | FOR THE 26?X12? SUPPLY AND RETURN DUCTS OF HP-2L-3. THE | | | RESPONSE NARRATIVE IS CLAIMING AN EXCEPTION PER SECTION | | | 716.5.2 FBC-10 BUILDING. PLEASE INDICATE WHICH OF THE | | | THREE EXCEPTIONS LISTED IN THE SECTION IS BEING CLAIMED | | | AND PLACE NOTES ON THE PLAN TO CLARIFY. | | | | | | 41) COMMENT #14L STILL EXISTS: SEE COMMENT #37 ABOVE | | | FOR COMPLIANCE INFORMATION. | | | | | | 42) COMMENT #14M FROM THE 1ST REVIEW WAS ?ADVISORY? | | | PENDING BUILDING REVIEW REGARDING THE 2-STORY ATRIUM AT | | | THE LOBBY. | | | | | | 43) SHEET M2.02: PROVIDE AIR BALANCE CALCULATIONS | | | | | | 44) M2.02: PROVIDE EQUIPMENT SCHEDULES FOR THE VARIOUS | | | UNLABELED (EF) EXHAUST FANS SERVING THE MEN'S AND | | | WOMEN'S BATH AND LOCKER ROOMS IN THE SOUTH CORE. | | | | | | 45) M2.02: SHOW THE RETURN SYSTEM IN THE MASSAGE ROOM. | | | | | | 46) M2.02: PROVIDE A MOTORIZED DAMPER FOR THE O/A DUCT | | | TO HP-2L-1. | | | | | | 47) M2.02: PROVIDE A DETAIL FOR THE RETURN AIR THROUGH | | | THE CEILING COVES, AND INDICATE THE RETURN AIR CFM | | | CAPACITIES OF THE DEVICES- SEE NOTE #2. | | | | | | 48) COMMENTS #15 STILL EXISTS: AS DIRECTED BY THE | | | RESPONSE NARRATIVE, I REVIEWED SHEET M2.53A, HOWEVER | | | THE DUCT LAYOUT PLANS APPEAR INCOMPLETE WITH MANY OF | | | THE DUCT SIZES IN THE CORE AND THE SUITES NOT SHOWN AND | | | DIFFUSERS AND OTHER COMPONENTS NOT IDENTIFIED OR TAGGED | | | PROPERLY. ADDITIONALLY THERE IS AN UNIDENTIFIED DUCT | | | FROM THE NORTH CORE SHAFT THAT APPEARS TO BE CONVEYING | | | O/A INTO THE CORRIDOR AND AIR INTO THE GUEST SUITE 11-1 | | | BATH. THIS DOES NOT MATCH THE REVISE O/A SYSTEM SHOWN | | | ON M2.02. A) PLEASE CLARIFY WHY CONDENSER WATER PIPING | | | IS SHOWN ON THIS RCP PLAN. TYPICALLY THE PIPING LAYOUTS | | | AND DETAIL ARE PLACED ON MECHANICAL PIPING PLAN SHEETS. | | | | | | 49) COMMENTS #16- 19 STILL EXIST FOR SHEETS M2.03, | | | M2.05, M2.17, M2.18, M2.20, M2.21, M2.22, M2.23, M2.24, | | | & M2.25 ALL OF THESE PLAN SHEETS HAVE INCOMPLETE DUCT | | | LAYOUT PLANS IN THE NORTH AND SOUTH CORES, AND ONLY | | | PROVIDE RCP FOR THE RESIDENTIAL AREAS. THE NARRATIVE | | | STATES THAT THE DETAILS ARE FOUND ON THE ENLARGED | | | SHEETS, HOWEVER THE CORE LAYOUTS ON THESE SHEETS ARE | | | ALSO INCOMPLETE. PLEASE REVIEW AND REVISE. PLEASE NOTE | | | THAT SOME SHEETS HAVE WATER PIPING DETAILS WHICH, AS | | | STATED BEFORE, SHOULD BE ON SEPARATE MECHANICAL SHEETS. | | | | | | 50) COMMENTS #20A, 20B, & 20C REGARDING THE BOILER | | | INSTALLATION AND VENTING ARE RESERVED PENDING SUBMITTAL | | | OF MANUFACTURER'S SPECIFICATIONS WITH APPROVAL | | | SIGNATURE BY THE EOR. | | | | | | 51) COMMENT #20D IS RESERVED PENDING APPROVED | | | SUBMITTALS. | | | | | | 52 ) COMMENT #20E STILL EXISTS: THE NARRATIVE | | | REFERENCES SHEET M4.01 FOR THE REQUESTED DETAILS | | | HOWEVER THE DETAILS ARE SHOWN ARE INCOMPLETE. PLEASE | | | PROVIDE THE CLEARANCE HEIGHT ABOVE THE ROOF SURFACE TO | | | THE BOTTOM OF THE COOLING TOWER- SEE DETAIL (4/S5.31) | | | AND PROVIDE THE DIMENSION. PLEASE NOTE THAT SHEET | | | | | | 53 ) COMMENT #20F STILL EXISTS. AS NOTED IN THE DETAILS | | | ON SHEET M4.01, PROVIDE COMPLETE ENGINEERED PLANS AND | | | DETAILS FOR INSTALLATION OF ALL ROOFTOP MECHANICAL | | | EQUIPMENT AND SUPPORTS. | | | | | | 54) COMMENT #20G IS RESERVED PENDING FURTHER | | | INFORMATION AND PLAN REVISIONS. | | | | | | 55) SHEET M5.03: PLEASE REVIEW THE FOLLOWING LIST OF | | | MECHANICAL CODE COMPLIANCES FOR THE DRYER EXHAUST: | | | | | | 504.8 COMMON EXHAUST SYSTEMS FOR CLOTHES DRYERS LOCATED | | | IN MULTISTORY STRUCTURES. | | | WHERE A COMMON MULTISTORY DUCT SYSTEM IS DESIGNED AND | | | INSTALLED TO CONVEY EXHAUST FROM MULTIPLE CLOTHES | | | DRYERS, THE CONSTRUCTION OF THE SYSTEM SHALL BE IN | | | ACCORDANCE WITH ALL OF THE FOLLOWING: | | | | | | 1. THE SHAFT IN WHICH THE DUCT IS INSTALLED SHALL BE | | | CONSTRUCTED AND FIRE-RESISTANCE RATED AS REQUIRED BY | | | THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2. DAMPERS SHALL BE PROHIBITED IN THE EXHAUST DUCT. | | | PENETRATIONS OF THE SHAFT AND DUCTWORK SHALL BE | | | PROTECTED IN ACCORDANCE WITH SECTION 607.5.5, EXCEPTION | | | 2. | | | | | | 3. RIGID METAL DUCTWORK SHALL BE INSTALLED WITHIN THE | | | SHAFT TO CONVEY THE EXHAUST. THE DUCTWORK SHALL BE | | | CONSTRUCTED OF SHEET STEEL HAVING A MINIMUM THICKNESS | | | OF 0.0187 INCH (0.4712 MM) (NO. 26 GAGE) AND IN | | | ACCORDANCE WITH SMACNA DUCT CONSTRUCTION STANDARDS. | | | | | | 4. THE DUCTWORK WITHIN THE SHAFT SHALL BE DESIGNED AND | | | INSTALLED WITHOUT OFFSETS. | | | | | | 5. THE EXHAUST FAN MOTOR DESIGN SHALL BE IN ACCORDANCE | | | WITH SECTION 503.2. | | | | | | 6. THE EXHAUST FAN MOTOR SHALL BE LOCATED OUTSIDE OF | | | THE AIRSTREAM. | | | | | | 7. THE EXHAUST FAN SHALL RUN CONTINUOUSLY, AND SHALL BE | | | CONNECTED TO A STANDBY POWER SOURCE. | | | | | | 8. EXHAUST FAN OPERATION SHALL BE MONITORED IN AN | | | APPROVED LOCATION AND SHALL INITIATE AN AUDIBLE OR | | | VISUAL SIGNAL WHEN THE FAN IS NOT IN OPERATION. | | | | | | 9. MAKEUP AIR SHALL BE PROVIDED FOR THE EXHAUST SYSTEM. | | | | | | 10. A CLEANOUT OPENING SHALL BE LOCATED AT THE BASE OF | | | THE SHAFT TO PROVIDE ACCESSTO THE DUCT TO ALLOW FOR | | | CLEANING AND INSPECTION. THE FINISHED OPENING SHALL BE | | | NOT LESS THAN 12 INCHES BY 12 INCHES (305 MM BY 305 | | | MM). | | | | | | 11. SCREENS SHALL NOT BE INSTALLED AT THE TERMINATION. | | | | | | 12. THE COMMON MULTISTORY DUCT SYSTEM SHALL SERVE ONLY | | | CLOTHES DRYERS AND SHALL BE INDEPENDENT OF OTHER | | | EXHAUST SYSTEMS. | | | | | | PROVIDE NOTES AND DETAILS ON THE PLANS TO INDICATE | | | COMPLIANCE WITH ALL REQUIREMENTS. A) SHOW THE LOCATION | | | OF THE DRYER EXHAUST SHAFT MAKE UP AIR DUCTS AND | | | DAMPERS ON THE MECHANICAL FLOOR PLANS. PROVIDE | | | CALCULATIONS. | | | | | | 56) SHEET M5.07 SHOWS CT-01 AND CT-2, HOWEVER THE | | | COOLING TOWER IS INDICATED AS CT-1 ON ALL OTHER SHEETS- | | | PLEASE CLARIFY. | | | | | | 57) M2.54A: THE 30"X10" DUCT CANNOT PENETRATE INTO | | | STAIR #3- SECTION 1022.4 FBC-10 BUILDING A) LABEL ALL | | | THE EXHAUST FAN CHASES. B) SHOW ALL COMPONENTS OF THE | | | RETURN AIR SYSTEMS AND PROVIDE DETAILS B) CLARIFY HOW | | | THE UNITS WILL BE VENTILATED- NATURALLY OR MECHANICALLY | | | AND PROVIDE DETAILS AND CALCULATIONS. C) PROVIDE AN AIR | | | DEVICE SCHEDULE D) INDICATE HOW ACCESS FOR SERVICE AND | | | REPLACEMENT OF THE HP UNITS WILL BE PROVIDED. E) SHOW | | | ALL DUCT DIMENSIONS IN THE NORTH CORE. F) INDICATE HOW | | | THE TEL/ELEC ROOMS WILL BE VENTILATED. | | | | | | 58) M2.54B: THE 18"X10" RETURN DUCT TO HP-F CANNOT | | | PENETRATE INTO STAIR #1- SECTION 1022.4 FBC-10 BUILDING | | | A) LABEL ALL THE EXHAUST FAN CHASES. B) SHOW ALL | | | COMPONENTS OF THE RETURN AIR SYSTEMS AND PROVIDE | | | DETAILS B) CLARIFY HOW THE UNITS WILL BE VENTILATED- | | | NATURALLY OR MECHANICALLY, AND PROVIDE DETAILS AND | | | CALCULATIONS. C) PROVIDE AN AIR DEVICE SCHEDULE D) | | | INDICATE HOW ACCESS FOR SERVICE AND REPLACEMENT OF THE | | | HP UNITS WILL BE PROVIDED. E) SHOW ALL DUCT DIMENSIONS | | | IN THE SOUTH CORE. F) INDICATE HOW THE TEL/ELEC ROOMS | | | WILL BE VENTILATED. | | | | | | 59) SHEETS M2.55A&B, M2.56A B, M2.56A&B, M2.57A&B, | | | M2.58B, M2.59A&B, M2.60B, M2.61A & M2.61A: THE DUCTS | | | PENETRATING THE EXIST STAIRWAY ENCLOSURES ARE NOT | | | PERMITTED PER SECTION 1022.4 FBC-10 BUILDING. PLEASE | | | REVIEW AND REVISE THE PLANS PER COMMENTS #57 & 58 A-F | | | PRINTED ABOVE. SHOW ALL DUCT, DIFFUSER, AND RETURN | | | GRILL DIMENSIONS AND CFM CAPACITIES. | | | | | | 60) IN ORDER TO EXPEDITE THE REVIEW PROCESS, PLEASE | | | OVERLAY THE LIFE SAFETY PLANS ONTO THE MECHANICAL DUCT | | | LAYOUT PLANS SO THAT FIRE-RATED AND REQUIRED FD'S AND | | | FSD'S ARE READILY IDENTIFIED. IT IS ALSO HELPFUL TO | | | PROVIDE ROOM IDENTIFICATIONS ON THE PLANS. | | | | | | THIS SECOND REVIEW IS CONCLUDED, HOWEVER THERE MAY BE | | | ADDITIONAL COMMENTS FOLLOWING RESUBMITTAL OF CORRECTED | | | PLANS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2016-02-04 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2016-02-04 |
Time |
15:13 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2016-01-27 |
Time |
12:10 |
Sent To |
|
|
| Notes |
| 2016-02-04 15:14:26 | | | | 1ST REVIEW: FBC 2014 MECHANICAL | | | PERMIT # 15111020 | | | THE BRISTOL | | | 1/28/16 | | | | | | 1) PLEASE COMPARE THE DATA FOR THE AC SYSTEMS LISTED IN | | | THE SUBMITTED ENERGY CALCULATION FORM 506-2010 WITH THE | | | EQUIPMENT SCHEDULES ON SHEETS M6.01 & M6.02 AND THE | | | CONDENSER WATER RISERS SHOWN ON SHEETS M5.05 AND M5.06. | | | THE CONFLICTS AND INCONSISTENCIES IN UNIT | | | IDENTIFICATIONS AND SIZING ARE TOO NUMEROUS TO LIST IN | | | THIS REVIEW BUT HERE ARE SOME OF THE MORE APPARENT | | | ISSUES A) THE RISERS INDICATE 191 HEAT PUMPS HOWEVER | | | THE TOTAL NUMBER OF HEAT PUMPS LISTED IN THE | | | CALCULATIONS IS 39. B) THE RISER DRAWING SHOWS HP 135, | | | 136, AND 215, WHICH APPEAR TO BE DESIGNATED AS OAU- 1, | | | 2, & 3 IN THE SCHEDULES AND CALCULATIONS, HOWEVER THE | | | CAPACITIES SHOWN FOR THESE UNITS IN THE RISERS DO NOT | | | MATCH THE CAPACITIES LISTED IN THE SCHEDULES. | | | C) THE CALCULATIONS SHOW 1-TON, 1.25-TON, AND 10-TON | | | HEAT PUMPS WHICH ARE NOT SHOWN IN THE WSHP EQUIPMENT | | | SCHEDULES ON SHEET M-601. D) OAU #2, AND THE 2.5-TON, | | | 3-TON, AND 5-TON HEAT PUMPS ARE NOT INCLUDED IN THE | | | CALCULATIONS. E) THE AREA CALCULATION ON THE FRONT | | | COVER OF THE ENERGY FORM INDICATES 412741 SF, HOWEVER | | | THE PERMIT APPLICATION INDICATES 319,010 SF. F) THE | | | FORM INDICATES A COOLING CAPACITY OF 183657 BTUH FOR A | | | 1.5 TON UNIT? G) THE EER'S LISTED IN THE CALCULATIONS | | | FOR MANY OF THE SYSTEMS DO NOT MATCH THE EER'S LISTED | | | IN THE SCHEDULES. H) NO COMPLIANCE DATA IS LISTED FOR | | | THE SUPPLY AND RETURN CONDENSER WATER PIPING AND | | | INSULATIONS. I) IT APPEARS THAT THERE ARE ALSO MANY | | | CONFLICTS BETWEEN THE CONDENSER PIPING RISERS AND THE | | | MECHANICAL LAYOUT PLANS PERTAINING TO UNIT | | | IDENTIFICATIONS AND WATER PIPING SIZES NOT MATCHING. | | | PLEASE CORRECT ALL OF THE PLANS, RISERS AND | | | CALCULATIONS SO THEY MATCH AND PROVIDE A COMPLETE, | | | ACCURATE ENERGY SUBMITTAL. | | | | | | 2) CALCULATIONS REQUIRED BUT NOT PROVIDED: A) AC | | | COOLING AND HEATING SYSTEM SIZING FOR ALL OF THE HEAT | | | PUMPS AND DEDICATED OUTSIDE AIR UNITS- SECTION 503.2.1 | | | FBC-10 ENERGY CONSERVATION. B) MINIMUM VENTILATION | | | CALCULATIONS FOR ALL OCCUPIED ROOMS AND SPACES- TABLE | | | 403.3 FBC-10 MECHANICAL. PROVIDE A TABLE THAT INDICATES | | | THE REQUIRED AND PROVIDED CFM'S OF OUTDOOR AIR. C) | | | EXHAUST VENTILATION CALCULATIONS FOR THE PARKING | | | GARAGES AND PRIVATE GARAGES- REFER TO SECTION 404 AND | | | TABLE 403.1. D) EXHAUST VENTILATION CALCULATIONS FOR | | | REQUIRED ROOMS AND AREAS INCLUDING THE TRASH STORAGE, | | | NAIL SALON, POOL EQUIPMENT ROOMS, GENERATOR AND TANK | | | ROOMS, ETC. | | | | | | 3) SMOKE CONTROL AND STAIRWELL/ELEVATOR PRESSURIZATION | | | PLANS: THERE APPEARS TO BE SOME CONFLICTS AND MISSING | | | INFORMATION BETWEEN THE ARCHITECTURAL AND MECHANICAL | | | PLANS AND RISERS, AND THE RATIONAL ANALYSIS FROM SLF | | | FIRE PROTECTION ENGINEERS. A) THE CAPACITIES AND | | | LOCATIONS OF THE STAIRWAY AND ELEVATOR HOIST-WAY | | | PRESSURIZATION FANS AS SHOWN ON THE PLANS AND THE | | | EQUIPMENT SCHEDULES DIFFER FROM WHAT IS SPECIFIED IN | | | THE SMOKE CONTROL ANALYSIS FROM SLS FIRE PROTECTION | | | ENGINEERS. THE ANALYSIS SPECIFIES STAIRS #1-4 | | | PRESSURIZATIONS OF 10,000 CFM AT THE 25TH LEVEL AND | | | 5000 CFM'S AND THE 1ST LEVEL, HOWEVER THE RISER DRAWING | | | ON SHEET M5.04 INDICATES 15,000 CFM FANS AT THE 26TH | | | LEVEL FOR STAIRS #1-3, AND 15,000 CFM'S FOR STAIR #4 AT | | | THE GROUND FLOOR PARKING LEVEL. THESE CFM CAPACITIES | | | CONFLICT WITH THE FAN SCHEDULE ON SHEET M-602 WHICH | | | INDICATES 10,000 CFM INLINE FANS FOR STAIRS #1-4. B) | | | THE ANALYSIS SPECIFIES 20,000 CFM PRESSURIZATION FOR | | | ELEVATOR HOIST-WAYS #1-4 AT THE 25TH LEVEL, HOWEVER THE | | | SCHEDULE LISTS THEM AT 15,000 CFM'S, AND THE RISER | | | SHOWS CAPACITIES OF 20,000 CFM'S FOR #1 & 2 AND 30,000 | | | CFM?S FOR #3 & 4. C) SHEET A3.21 SHOWS ELEVATOR | | | HOIST-WAYS #2 & 4 TERMINATING AT THE 24TH LEVEL, BUT | | | THE RISER DRAWING SHOWS THEM TERMINATING AT THE 26TH | | | LEVEL. D) SHEETS M2.26, M2.27, M5.05, M-602: THE | | | FOLLOWING LIST OF PRESSURIZATION AND SMOKE CONTROL FANS | | | ARE SHOWN IN THE SCHEDULE AND RISER BUT NOT SHOWN ON | | | THE 26TH LEVEL OR ROOF LEVEL MECHANICAL PLANS: SPF-2, | | | SPF-3, EPF-2, EPF-4, AND SEF-1. PLEASE SHOW THE | | | LOCATIONS OF THE FANS ON THE ROOF PLANS AND PROVIDE | | | CLEARANCE DISTANCE MEASUREMENTS FOR ALL INLETS TO | | | MECHANICAL AND GRAVITY EXHAUST OUTLETS. REFER TO | | | SECTION 708.14.2.1 FBC-10 BUILDING FOR PRESSURIZATION | | | INLET MINIMUM CLEARANCE DISTANCES TO EXHAUST OUTLETS. | | | E) PLEASE NOTE THAT ALL MANUFACTURER?S SPECIFICATIONS | | | FOR MECHANICAL EQUIPMENT AND COMPONENTS OF THE SMOKE | | | CONTROL SYSTEM ( FANS, DAMPERS, DUCT AND AREA SMOKE | | | DETECTORS, AIR INTAKE AND EXHAUST LOUVERS ETC.) SHALL | | | BE REVIEWED AND APPROVED BY THE ENGINEER OF RECORD, AND | | | SHALL BE PART OF THE SUBMITTAL PACKAGE- REFER TO | | | SECTIONS 909.10 - 909-10.5 FBC-10 BUILDING. | | | | | | 4) PROVIDE AIR DEVICE AND AIR DISTRIBUTION SCHEDULES | | | FOR ALL COMPONENTS OF THE HVAC AND SMOKE CONTROL | | | SYSTEMS- MANY DEVICE SYMBOLS ARE SHOWN ON THE PLANS | | | WITH NO SCHEDULE TO REFERENCE. | | | | | | 5) SHEETS M2.26 & M2.27: THE PLANS INDICATE MANY ROOF | | | LEVEL TEF'S AND KEF'S. WHERE ARE THE EQUIPMENT | | | SCHEDULES FOR THESE FANS?- I AM NOT SEEING THEM ON | | | EITHER M-601 OR M-602. | | | | | | 6) PROVIDE A CONDENSATE DISPOSAL RISER AND ALSO PIPING | | | DIAGRAMS FOR EACH LEVEL. INDICATE THE TYPES AND SIZES | | | OF THE PIPING, PIPING INSULATIONS AND DISCHARGE | | | LOCATIONS. PLEASE NOTE THAT SEC. 90-126 WPB CODE OF | | | ORDINANCES PROHIBITS CONDENSATE FROM COOLING COILS TO | | | BE DISCHARGED INTO THE SANITARY SEWER SYSTEM. | | | | | | 7) AS NUMEROUS MECHANICAL COMPONENTS SUCH AS LOUVERS | | | AND EQUIPMENT STANDS SUBJECT TO WIND LOAD ARE SHOWN IN | | | THE PLANS PLEASE NOTE THAT FLORIDA PRODUCT APPROVALS | | | AND/OR MIAMI-DADE NOA'S MUST BE SUBMITTED WITH REVIEW | | | AND APPROVAL SIGNATURES FROM THE EOR. IF ANY OF THESE | | | PRODUCTS ARE TO BE SUBMITTED AFTER PERMITTING, PLEASE | | | REVIEW THE FOLLOWING SECTIONS FOR THE WPB AMENDMENTS TO | | | THE FBC-10 BUILDING: DEFERRED SUBMITTAL: 107.3.4.2 | | | DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS SECTION, | | | DEFERRED SUBMITTALS ARE DEFINED AS THOSE PORTIONS OF | | | THE DESIGN THAT ARE NOT SUBMITTED AT THE TIME OF THE | | | APPLICATION AND THAT ARE TO BE SUBMITTED TO THE | | | BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. DEFERRAL | | | OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR APPROVAL OF | | | THE BUILDING OFFICIAL. THE REGISTERED DESIGN | | | PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST THE | | | DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS FOR | | | REVIEW BY THE BUILDING OFFICIAL. DOCUMENTS FOR DEFERRED | | | SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE WHO SHALL | | | REVIEW THEM AND FORWARD THEM TO THE BUILDING OFFICIAL | | | WITH A NOTATION INDICATING THAT THE DEFERRED SUBMITTAL | | | DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE IN GENERAL | | | CONFORMANCE TO THE DESIGN OF THE BUILDING. THE DEFERRED | | | SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE | | | DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE | | | BUILDING OFFICIAL. A)DEFERRED SUBMITTAL. 2010 FBC | | | 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE | | | REGULATED BY THE DCA RULE 9N-03 SHALL BE REVIEWED AND | | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | | SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 8) THE VARIOUS AIR INTAKES AND EXHAUST OUTLETS LOCATED | | | ON THE EXTERIOR WALLS OF THE BUILDING MUST BE REVIEWED | | | TO MEET COMPLIANCE WITH REQUIRED CLEARANCE DISTANCES AS | | | OUTLINED IN SECTION 401.1 AND 501.2.1. PROVIDE CLEAR, | | | DIMENSIONED ELEVATION VIEWS OF THE OPENINGS AND NOTES | | | IN ORDER TO VERIFY COMPLIANCE. | | | | | | 9) PROVIDE UL TESTED AND APPROVED FIRE-STOPPING | | | ASSEMBLIES AND DETAILS FOR ALL DUCTS PENETRATING RATED | | | WALLS AND SHAFTS. IF THE DETAILS ARE SHOWN ON A | | | ARCHITECTURAL PLAN, PLEASE PROVIDE A NOTE REFERENCING | | | THAT PLAN SHEET. | | | | | | 10) PROVIDE A DETAIL FOR A TYPICAL FIRE DAMPER ACCESS | | | PANEL, AND SYMBOLS ON THE PLANS TO INDICATE LOCATIONS. | | | | | | 11) SHEET M2.0P1: | | | A) THE PLAN SHEET IS LABELED AS BOTH P1 AND P2: PLEASE | | | CORRECT. | | | B) VERIFY THE AIR INTAKES FOR SPF-4 ARE IN COMPLIANCE | | | WITH SECTION 513.10.3. PROVIDE AN ELEVATION VIEW AND | | | CLEARANCE DISTANCE MEASUREMENTS. | | | C) CLARIFY THE PURPOSES OF THE AIR SUPPLY FANS PGSF-1A | | | & 1B AND HOW THEY WERE SIZED. ARE THEY PROVIDING THE | | | MAKE-UP AIR FOR THE GARAGE EXHAUST? IF THAT IS THE | | | PURPOSE, PLEASE INCLUDE THEM IN THE CONTROL DIAGRAM ON | | | SHEET M5.07. PROVIDE AN ELEVATION VIEW AND CLEARANCE | | | DISTANCE MEASUREMENTS FOR THE INLETS. | | | D) NITROGEN DIOXIDE DETECTORS IN CONJUNCTION WITH | | | CARBON MONOXIDE DETECTORS ARE REQUIRED IN THE PARKING | | | GARAGE, HOWEVER THE PLAN IS INDICATING ONLY THE CO | | | DETECTORS. PLEASE NOTE THAT THE MANUFACTURER'S | | | SPECIFICATIONS FOR THE DETECTORS SHALL BE REVIEWED AND | | | APPROVED BY THE E.O.R AND BE PART OF THE SUBMITTAL | | | PACKAGE. REFER BACK TO COMMENT #2C FOR EXHAUST | | | CALCULATION REQUIREMENT. | | | E) PROVIDE DUCT CONNECTION, REINFORCEMENT, SEALING, AND | | | HANGING DETAILS FOR THE 2HR. FIRE-RATED FLAMEBAR DUCT, | | | AND THE OUTSIDE AIR DUCTS IN THE GARAGE. INDICATE THE | | | HEIGHTS OF THE DUCTS ABOVE THE FINISHED GARAGE FLOOR. | | | PLEASE NOTE MANUFACTURER'S SPECIFICATIONS AND | | | INSTALLATIONS FOR THE DUCTWORK MUST BE REVIEWED AND | | | APPROVED BY THE E.O.R. AND INCLUDED IN THE SUBMITTAL | | | PACKAGE. | | | F) PROVIDE SUPPORT AND PROTECTION DETAILS FOR ALL | | | EXPOSED PIPING IN THE GARAGE INCLUDING THE CONDENSER | | | WATER SUPPLY AND RETURN PIPING, AND THE GENERATOR FUEL | | | OIL PIPING. PROVIDE A SUBMITTAL FOR THE PIPE | | | INSULATION. | | | G) PROVIDE AN ELEVATION VIEW AND CLEARANCE DISTANCE | | | MEASUREMENTS FOR THE OUTDOOR AIR INTAKE ON THE NORTH | | | SIDE THAT IS SUPPLYING THE CORES- SEE SECTION 401.4. | | | H) LABEL THE OUTSIDE AIR INTAKE FOR OAU-3 AND PROVIDE | | | CLEARANCE DISTANCE MEASUREMENTS- SECTION 401.4 | | | I) PROVIDE ELEVATION VIEWS AND CLEARANCE DISTANCE | | | MEASUREMENTS FOR THE GARAGE AND TRASH EXHAUST OUTLETS | | | ON THE NORTH SIDE- REFER TO SECTION 501.3.1. PLEASE | | | INCLUDE THE OUTLETS FOR PGEF-P2-1A & 1B BY THE STAIR #9 | | | J) SOUTH CORE: LABEL THE SUPPLY AND RETURN CFM'S AT THE | | | SUPPLY DIFFUSER AND RETURN GRILLS IN THE FIREMAN'S | | | VESTIBULE | | | K) SOUTH CORE: PROVIDE AN EXHAUST FAN SCHEDULE FOR | | | EF-P2-2. | | | L) SOUTH CORE: FIRE AND FIRE/SMOKE DAMPERS MISSING AT | | | ALL DUCTS PENETRATING THE EXTERIOR AND INTERIOR | | | FIRE-RATED WALLS OF THE CORE. | | | M) SOUTH CORE: INDICATE HOW ACCESS FOR SERVICE AND | | | REPLACEMENT OF THE HEAT PUMPS ABOVE THE CEILING WILL BE | | | PROVIDED. SHOW THE LOCATIONS OF THE PANELS AND | | | CONSTRUCTION DETAILS. | | | N) NORTH CORE: NO OUTSIDE AIR DUCT CONNECTIONS TO THE | | | HEAT PUMPS INSIDE THE CORE ARE SHOWN IN THE DRAWING. | | | O) NORTH CORE: THE SUPPLY AND RETURN DIFFUSERS AND | | | GRILLS ARE NOT LABELED AND NO CFM'S ARE SHOWN. | | | P) NORTH CORE: FIRE DAMPERS MISSING AT MOST OF THE DUCT | | | PENETRATING THE EXTERIOR AND INTERIOR FIRE-RATED WALLS | | | OF THE CORE. | | | Q) NORTH CORE: INDICATE HOW ACCESS FOR SERVICE AND | | | REPLACEMENT OF THE HEAT PUMPS ABOVE THE CEILING WILL BE | | | PROVIDED. SHOW THE LOCATIONS OF THE PANELS AND | | | CONSTRUCTION DETAILS. | | | R) MEP ROOM: FIRE DAMPER MISSING FOR THE 28"X12" DUCT | | | PENETRATING THE RATED MEP ROOM WALL. | | | S) MEP ROOM: OAU-3 IS A WATER-COOLED UNIT PER THE | | | SCHEDULE. INDICATE HOW WATER IS BEING SUPPLIED TO THE | | | UNIT. | | | T) POOL EQUIPMENT ROOM: IDENTIFY AND LABEL ALL | | | EQUIPMENT IN THE ROOM AND PROVIDE SCHEDULES FOR EACH. | | | PROVIDE EXHAUST VENTILATION CALCULATIONS FOR THE ROOM, | | | FAN SCHEDULES FOR PEEF-1 AND PESF-1 (SHOWN ON THE LOBBY | | | 1 LEVEL), AND SUBMITTALS FOR THE SUPPLY AND EXHAUST | | | DUCTWORK AND FANS REVIEWED AND APPROVED BY THE EOR. SEE | | | SECTION 304.3.1 FOR REQUIREMENTS FOR FUEL-FIRED | | | APPLIANCES IN THE ROOM. | | | U) INDOOR DOG RUN: PROVIDE AN EXHAUST VENTILATION | | | SYSTEM IN ACCORDANCE WITH TABLE 403.3. INCLUDE | | | CALCULATIONS, FAN SCHEDULES, EXHAUST DUCT RUN DETAILS | | | AND TERMINATION LOCATIONS, AND HOW MAKE-UP AIR IS TO BE | | | PROVIDED. | | | V) PROVIDE EQUIPMENT SCHEDULES FOR THE CIRCULATION FANS | | | AND INDICATE THE HEIGHT MEASUREMENTS OF THE FANS FROM | | | THE FINISH FLOORS TO THE LOWEST EDGE OF THE FAN- SEE | | | SECTION 304.6. | | | | | | 12) SHEET M2.0P2: | | | A) REFER TO SECTION 301.16 AND PROVIDE EVIDENCE TO | | | INDICATE COMPLIANCE FOR MECHANICAL EQUIPMENT LOCATED IN | | | A FLOOD HAZARD AREA. SOME OF THE EQUIPMENT INCLUDED ARE | | | THE HEAT PUMPS, THE FANS, THE DAMPERS, THE DUCTWORK, | | | THE DETECTORS ETC. 301.16 FLOOD HAZARD. | | | FOR STRUCTURES LOCATED IN FLOOD HAZARD AREAS, | | | MECHANICAL SYSTEMS, EQUIPMENT AND APPLIANCES SHALL BE | | | LOCATED AT OR ABOVE THE ELEVATION REQUIRED BY SECTION | | | 1612 OF THE FLORIDA BUILDING CODE, BUILDING FOR | | | UTILITIES AND ATTENDANT EQUIPMENT. | | | EXCEPTION: MECHANICAL SYSTEMS, EQUIPMENT AND APPLIANCES | | | ARE PERMITTED TO BE LOCATED BELOW THE ELEVATION | | | REQUIRED BY SECTION 1612 OF THE OF THE FLORIDA BUILDING | | | CODE, BUILDING FOR UTILITIES AND ATTENDANT EQUIPMENT | | | PROVIDED THAT THEY ARE DESIGNED AND INSTALLED TO | | | PREVENT WATER FROM ENTERING OR ACCUMULATING WITHIN THE | | | COMPONENTS AND TO RESIST HYDROSTATIC AND HYDRODYNAMIC | | | LOADS AND STRESSES, INCLUDING THE EFFECTS OF BUOYANCY, | | | DURING THE OCCURRENCE OF FLOODING UP TO SUCH ELEVATION. | | | B) GARAGE EXHAUST SYSTEM: CLARIFY HOW THE GARAGE | | | EXHAUST VENT OPENING ON THE NORTH SIDE AND THE EXHAUST | | | FANS (PGEF-P2-1A & 1B SHOWN ON M2.0P1) WERE SIZED- | | | REFER TO COMMENT #2C. PROVIDE THE DIMENSIONS OF THE | | | VENT OPENING AND CONSTRUCTION DETAILS. | | | C) CLARIFY HOW MAKE-UP AIR IS BEING SUPPLIED FOR THE | | | GARAGE EXHAUST. | | | D) PGEF-P1-E AT THE LOADING DOCK IS NOT INCLUDED IN THE | | | FAN SCHEDULE ON M-602, AND THE EXACT LOCATION OF THE | | | FAN IS NOT CLEAR ON THE PLAN. PLEASE CORRECT AND | | | PROVIDE EXHAUST VENTILATION CALCULATIONS. | | | E) PROVIDE A MEANS OF VENTILATION FOR THE CORRIDORS | | | ADJOINING THE PRIVATE GARAGES IN COMPLIANCE WITH | | | SECTION 404.3. | | | F) NITROGEN DIOXIDE DETECTORS IN CONJUNCTION WITH | | | CARBON MONOXIDE DETECTORS ARE REQUIRED IN THE PARKING | | | GARAGE, HOWEVER THE PLAN IS INDICATING ONLY THE CO | | | DETECTORS. PLEASE NOTE THAT THE MANUFACTURER?S | | | SPECIFICATIONS FOR THE DETECTORS SHALL BE REVIEWED AND | | | APPROVED BY THE EOR AND BE PART OF THE SUBMITTAL | | | PACKAGE. REFER BACK TO COMMENT #2C FOR EXHAUST | | | CALCULATION REQUIREMENT. | | | G) PROVIDE EQUIPMENT SCHEDULES FOR THE PRIVATE GARAGE | | | INLINE FANS AND THE OTHER INLINE FANS SHOWN THROUGHOUT | | | THE SPACE. AS PREVIOUSLY NOTED PROVIDE EXHAUST | | | VENTILATION CALCULATIONS FOR THE PRIVATE GARAGES. | | | H) PROVIDE FIRE DAMPERS FOR THE VENT LOUVERS SHOWN AT | | | THE FPL VAULT AND LOADING DOCK WALLS. | | | I) A SERIES OF LOUVERS ARE SHOWN ALONG THE SOUTH EAST | | | WALLS OF THE LOADING DOCK. HOW WERE THESE OPENINGS | | | SIZED AND ARE THEY BELOW THE FLOOD HEIGHT LEVEL. | | | PROVIDE AN ELEVATION VIEW THAT SHOWS REQUIRED CLEARANCE | | | DISTANCE MEASUREMENTS FOR AIR INTAKE AND EXHAUST. | | | SUBMITTALS FOR THE LOUVERS AND DAMPERS REVIEWED AND | | | APPROVED BY THE EOR ARE REQUIRED. | | | J) PROVIDE A THROUGH UL PENETRATION FIRE-STOPPING | | | ASSEMBLY DETAIL FOR THE O/A EXITING THE SHAFT ABOVE. | | | PROVIDE NOTES BY THE SHAFT INDICATING WHERE THE SHAFT | | | AND FIRE-STOPPING ASSEMBLY DETAILS CAN BE LOCATED IN | | | THE ARCHITECTURAL PAGES. | | | K) PROVIDE EQUIPMENT SCHEDULES FOR THE CIRCULATION FANS | | | AND INDICATE THE HEIGHT MEASUREMENTS OF THE FANS FROM | | | THE FINISH FLOORS TO THE LOWEST EDGE OF THE FAN- SEE | | | SECTION 304.6. | | | L) PROVIDE DUCT CONNECTION, REINFORCEMENT, SEALING, AND | | | HANGING DETAILS FOR THE OUTSIDE AIR AND EXHAUST DUCTS | | | IN THE GARAGE. INDICATE THE HEIGHTS OF THE DUCTS ABOVE | | | THE FINISHED GARAGE FLOOR. PLEASE NOTE MANUFACTURER'S | | | SPECIFICATIONS AND INSTALLATIONS FOR THE DUCTWORK MUST | | | BE REVIEWED AND APPROVED BY THE E.O.R. AND INCLUDED IN | | | THE SUBMITTAL PACKAGE. | | | M) PROVIDE SUPPORT AND PROTECTION DETAILS FOR ALL | | | EXPOSED PIPING IN THE GARAGE INCLUDING THE CONDENSER | | | WATER SUPPLY AND RETURN PIPING. PROVIDE SUBMITTALS FOR | | | ALL PIPE INSULATIONS. | | | N) SOUTH CORE, NORTH CORE, AND ADJACENT RESIDENT | | | STORAGE ROOMS: THE AC LAYOUT PLANS ARE IN- COMPLETE- | | | PROVIDE DUCT SIZES, DIFFUSER AND RETURN GRILL SIZES, | | | CFM CAPACITIES AT THE DIFFUSERS AND GRILLS, LOCATIONS | | | OF REQUIRED FIRE AND FIRE/SMOKE DAMPERS AT DUCT | | | PENETRATIONS, CONDENSER WATER PIPE SIZES ETC. | | | O) SOUTH CORE, NORTH CORE: INDICATE HOW ACCESS FOR | | | SERVICE AND REPLACEMENT OF THE HEAT PUMPS ABOVE THE | | | CEILING WILL BE PROVIDED. SHOW THE LOCATIONS OF THE | | | PANELS AND CONSTRUCTION DETAILS. | | | | | | 13) SHEET M2.01: | | | A) PROVIDE AN ELEVATION VIEW OF THE GENERATOR EXHAUST | | | LOUVER INDICATING REQUIRED CLEARANCE DISTANCE | | | MEASUREMENTS PER SECTION 501.2.1. | | | B) PROVIDE MANUFACTURER'S SPECIFICATIONS FOR THE | | | GENERATOR AND FUEL TANK REVIEWED AND APPROVED BY THE | | | EOR, AND INCLUDE IN THE REQUIRED SUBMITTAL PACKAGE. | | | PLEASE NOTE THAT IN ACCORDANCE WITH SECTION 909.11 | | | FBC-10 BUILDING, THE TRANSFER TO FULL STANDBY POWER | | | SHALL BE AUTOMATIC AND WITHIN 60 SECONDS OF FAILURE OF | | | THE PRIMARY POWER SYSTEMS. PLEASE REVIEW AND PROVIDE | | | THIS NOTE IN THE RATIONAL ANALYSIS OF THE SMOKE CONTROL | | | SYSTEM. | | | C) INDICATE THE REQUIRED CLEARANCE DISTANCES FOR THE | | | GENERATOR ROOM EXHAUST (501.2.1), SIZING CALCULATIONS | | | FOR THE FANS, AND FAN SCHEDULES. | | | D) PROVIDE AN ELEVATION VIEW OF THE GENERATOR ROOM | | | COMBUSTION AIR LOUVER INDICATING REQUIRED CLEARANCE | | | DISTANCE MEASUREMENTS, AND PROVIDE COMBUSTION AIR | | | CALCULATIONS. MANUFACTURER'S SPECIFICATIONS FOR THE | | | INTAKE LOUVER SHALL BE REVIEWED AND APPROVED BY THE EOR | | | AND INCLUDED IN THE SUBMITTAL PACKAGE WITH A FLORIDA | | | PRODUCT APPROVAL OR MIAMI-DADE NOA CERTIFYING WIND | | | RESISTANCE AND IMPACT PROTECTION. | | | E) PROVIDE ELEVATION VIEWS OF THE TANK ROOM AIR INTAKE | | | AND EXHAUST OUTLET WITH CLEARANCE DISTANCE | | | MEASUREMENTS. PROVIDE SIZING CALCULATIONS FOR THE | | | SYSTEM AS PREVIOUSLY NOTED AND A EQUIPMENT SCHEDULE FOR | | | THE FAN. PLEASE NOTE MANUFACTURER'S SPECIFICATIONS FOR | | | THE TANK SHALL BE REVIEWED AND APPROVED BY THE EOR AND | | | INCLUDED IN THE SUBMITTAL PACKAGE. | | | F) PROVIDE ENLARGED FUEL PIPING DIAGRAMS FOR THE | | | GENERATOR AND TANK. | | | G) INDICATE THE CLEARANCE DISTANCE MEASUREMENTS FOR THE | | | TWO O/A INTAKE INLETS ON THE EAST WALL ABOVE THE | | | LOADING DOCK- SECTION 401.1. | | | H) INDICATE THE CLEARANCE DISTANCE MEASUREMENTS FOR THE | | | MANI/PEDI EXHAUST OUTLET ON THE EAST WALL- SECTION | | | 501.2.1. | | | I) APPLY COMMENTS G & H ABOVE FOR THE POOL EQUIPMENT | | | ROOM VENTILATION INLET AND OUTLET ON THE SOUTH WALL. | | | J) NAIL SALON, REFER TO TABLE 403.3 FOOTNOTES B AND H | | | PERTAINING TO THE NAIL SALON: 1) INDICATE HOW THE | | | CONTAMINANTS AND ODORS FROM THE NAIL POLISHES ARE BEING | | | CAPTURED AT THEIR SOURCES- THE MANICURE AND PEDICURE | | | STATIONS. ADDITIONAL DETAILS AND PLAN VIEWS ARE | | | REQUIRED. 2) PROVIDE AN EXHAUST FAN EQUIPMENT SCHEDULE. | | | 3) CLARIFY HOW MAKE-UP AIR FOR THE EXHAUST IS BEING | | | PROVIDED AND REFER TO SECTION 403.2.1 (3) RECIRCULATION | | | OF THE AIR FROM THE SPACE IS PROHIBITED. HOW WILL THAT | | | BE ACCOMPLISHED WITH THE ABOVE CEILING PLENUM? PLEASE | | | SHOW THE LOCATIONS OF THE RETURN GRILLS. 3) SHOW THE | | | SUPPLY CFM?S AT THE DIFFUSER LOCATIONS, AND REFER TO | | | SECTION 606.2.2 FOR REQUIRED SMOKE DETECTOR FOR THE | | | COMMON PLENUM. | | | K) LAUNDRY ROOM: 1) PROVIDE A FD SYMBOL AT THE 28?X12? | | | DUCT PENETRATION INTO THE FIRE-RATED SHAFT. 2) THE | | | DRYER EXHAUST MUST BE INDEPENDENT AND NOT CONNECTED | | | WITH THE IRONER EXHAUST- SEE SECTION- 504.1. AND | | | CORRECT. 3) SUBMIT MANUFACTURER?S SPECIFICATIONS FOR | | | THE DRYERS AND IRONER WITH REVIEW AND APPROVAL | | | SIGNATURES BY THE EOR- SEE SECTION 504.7 AND SHOW THE | | | LOCATION OF THE EXHAUST FANS, AND INCLUDE FAN EQUIPMENT | | | SCHEDULES (IF APPLICABLE). 4) PROVIDE EXHAUST DUCT | | | DETAILS FOR BOTH THE DRYERS AND IRONER INCLUDING THE | | | TYPES AND SIZES OF DUCTS, SUPPORT AND HANGING DETAILS- | | | SEE SECTIONS 504.6.2, 504.6.4, 504.6.4.2, AND 504.7. 5) | | | PROVIDE PLAN AND ELEVATION VIEWS SHOWING DUCT | | | CONNECTIONS TO THE APPLIANCES, AND REQUIRED CLEARANCE | | | DISTANCES TO COMBUSTIBLES. 6) PROVIDE FIRE-STOPPING | | | DETAILS FOR DUCTS PENETRATING RATED WALLS. 7) PLEASE | | | NOTE COMMON DRYER EXHAUST DUCTS SHALL RUN CONTINUOUSLY | | | OR BE INTERLOCKED TO RUN TOGETHER. | | | L) SOUTH CORE: PROVIDE AN EXHAUST SYSTEM FOR THE TRASH | | | ROOM PER TABLE 6-4 ASHRAE 62.1-2010. PLEASE INCLUDE | | | CALCULATIONS, EXHAUST FAN SCHEDULE, EXHAUST DUCT | | | LAYOUT, TERMINATION LOCATION ETC. | | | M) SOUTH CORE: SHOW THE EXHAUST DUCT RUNS AND DUCT | | | SIZES AT THE MEN'S AND WOMEN'S TOILET ROOMS. | | | N) SOUTH CORE: IDENTIFY THE 3.5 TON UNIT IN THE PACKAGE | | | ROOM CLOSET. VERIFY A NON-COMBUSTIBLE DOOR WILL BE | | | INSTALLED FOR THE CLOSET AND ALL OTHER MECHANICAL | | | CLOSETS IN THE BUILDING- SECTION 603.1. SHOW THE | | | LOCATION OF THE PLENUM RETURN GRILL AT THE CLOSET, AND | | | THE LOCATIONS OF CEILING RETURN GRILLS IN THE LOBBY | | | LOUNGE. PLEASE INCLUDE DIMENSIONS AND CFM CAPACITIES | | | FOR EACH GRILL. | | | O) SOUTH CORE CORRIDOR: THE AC PLAN IS INCOMPLETE. | | | P) NORTH CORE: NO AC OR MEANS OF VENTILATION SHOWN IN | | | THE TEL/ELEC ROOM. | | | Q) NORTH CORE: CLARIFY IF A HP WILL BE INSTALLED FOR | | | THE FIREMAN'S VESTIBULE IN THE SAME MANNER ONE IS SHOWN | | | FOR THE SOUTH CORE, AN WHAT EQUIPMENT IS TO BE LOCATED | | | IN MECH. CL. 127. | | | R) NORTH CORRIDOR, LOUNGE 2, CLUB DINING: SHOW THE | | | LOCATIONS OF THE VAV BOXES AND PROVIDE EQUIPMENT | | | SCHEDULES. INDICATE HOW ACCESS FOR SERVICE AND | | | REPLACEMENT FOR THE BOXES ABOVE THE CEILING WILL BE | | | PROVIDED. SHOW THE LOCATION OF THE PLENUM RETURN GRILL | | | AT THE MECHANICAL CLOSET FOR THE 17.5 T SYSTEM, AND IN | | | THE CEILINGS OF THE CLUB DINING, LOUNGE 2, AND CORRIDOR | | | 105. PLEASE INCLUDE DIMENSIONS AND CFM CAPACITIES FOR | | | EACH GRILL. | | | S) GUEST SUITE 1-1 IS ALSO LABELED GUEST SUITE 1-2. | | | T) GUEST SUITES 1-1, 2-1, 4, & 4-4: INDICATE HOW | | | REQUIRED O/A IS BEING SUPPLIED TO THESE SUITES. | | | U) GUEST SUITES AC CLOSETS: INDICATE HOW ACCESS FOR | | | SERVICE AND REPLACEMENT OF THE HP-1 UNITS IN THE | | | CLOSETS WILL BE PROVIDED- THERE ARE NO DOORS SHOWN AT | | | THE CLOSETS. PLEASE PROVIDE ENLARGED PLAN VIEWS OF THE | | | CLOSETS INDICATED REQUIRED CLEARANCES, THE MEANS OF | | | RETURN AIR, PRIMARY AND SECONDARY AND CONDENSATE | | | DISPOSAL, AND CONDENSER WATER PIPING DIAGRAMS. | | | V) CLUB DINING AND SERVICE PANTRY: CLARIFY IF ANY | | | COOKING APPLIANCES WILL BE INSTALLED AND PROVIDE | | | DETAILS. PLEASE NOTE, TYPE I OR TYPE II EXHAUST HOODS | | | MAY BE REQUIRED. | | | | | | 14) M2.02: | | | A) REFER BACK TO COMMENT #8- REQUIRED CLEARANCE | | | DISTANCES FOR O/A INTAKES AND EXHAUST OUTLETS, AND SHOW | | | COMPLIANCE. | | | B) SOUTH: PROVIDE EQUIPMENT SCHEDULES FOR THE SAUNA AND | | | STEAM ROOM EXHAUST FANS AND SIZING CALCULATIONS. PLEASE | | | NOTE THE EXHAUST IS NOT SHOWN ACCURATELY PLACED IN THE | | | WOMEN'S ROOMS, AND NO MAKE-UP AIR IS BEING PROVIDED FOR | | | EITHER THE MEN'S OR WOMEN'S ROOMS. | | | C) SOUTH: REQUIRED EXHAUST SYSTEMS FOR THE WOMEN'S | | | SHOWER AND MEN'S HANDICAP SHOWER NOT SHOWN ON THE PLAN- | | | TABLE 403.3 | | | D) SOUTH: MECHANICAL CLOSETS ON THE EAST AND WEST SIDES | | | OF THE CORE BY THE RESTROOMS ARE SHOWN IN THE | | | ARCHITECTURAL PLANS- PLEASE IDENTIFY THE CLOSETS ON | | | THIS PLAN AND INDICATE WHAT EQUIPMENT IS CONTAINED IN | | | THE CLOSETS. | | | E) SOUTH: PLEASE SHOW THE LOCATIONS OF ALL RETURN | | | GRILLS AT THE MECH CLOSETS AND AT ALL OF THE CEILINGS | | | OF THE ROOMS AND THE SPACES. PROVIDE GRILL DIMENSIONS | | | AND CFM CAPACITIES. | | | F) ATRIUM: PROVIDE THE DIMENSIONS AND CFM CAPACITY OF | | | THE RETURN GRILL FOR HP-L2-5. | | | G) ATRIUM: SHOW THE REQUIRED DUCT SMOKE DETECTOR IN THE | | | SUPPLY PLENUM OF HP-L2-5. | | | H) NORTH CORE: PROVIDE AN EXHAUST SYSTEM FOR THE TRASH | | | ROOM PER TABLE 6-4 ASHRAE 62.1-2010. | | | I) NORTH CORE: PROVIDE VENTILATION FOR THE STORAGE ROOM | | | J) NORTH: PLEASE SHOW THE LOCATIONS OF ALL RETURN | | | GRILLS AT THE MECH CLOSETS AND AT ALL OF THE CEILINGS | | | OF THE ROOMS AND THE SPACES. PROVIDE GRILL DIMENSIONS | | | AND CFM CAPACITIES. | | | K) FIRE DAMPERS MISSING FOR THE 26"X12" DUCTS | | | PENETRATING THE FIRE-RATED MECHANICAL CLOSET WALLS. | | | L) NORTH GUEST SUITES: INDICATE HOW REQUIRED O/A IS | | | BEING SUPPLIED TO THESE SUITES. INDICATE HOW ACCESS FOR | | | SERVICE AND REPLACEMENT OF THE HP-1 UNITS IN THE | | | CLOSETS WILL BE PROVIDED- THERE ARE NO DOORS SHOWN AT | | | THE CLOSETS. PLEASE PROVIDE ENLARGED PLAN VIEWS OF THE | | | CLOSETS INDICATED REQUIRED CLEARANCES, THE MEANS OF | | | RETURN AIR, PRIMARY AND SECONDARY AND CONDENSATE | | | DISPOSAL, AND CONDENSER WATER PIPING DIAGRAMS. | | | M) PLEASE NOTE THAT SUBJECT TO PLAN REVISIONS BASED ON | | | STRUCTURAL REVIEW COMMENTS, ADDITIONAL FIRE AND | | | FIRE/SMOKE DAMPERS FOR DUCTS MAY BE REQUIRED ON BOTH | | | LOBBY LEVEL-1 AND AMENITY LEVEL-2. | | | | | | 15) M2.03: INCOMPLETE RCP PLANS- THE AC DIFFUSERS AND | | | GRILLS IN THE ROOMS ARE NOT LABELED AND NO DIMENSIONS | | | ARE SHOWN. PLEASE REFER TO COMMENT #14(L) PRINTED ABOVE | | | FOR THE GUEST SUITES ON THIS FLOOR. IDENTIFY ALL HP | | | UNITS BEING SERVED BY THE SUPPLY AND RETURN WATER | | | PIPING. DUCT LAYOUT PLANS FOR THE NORTH AND SOUTH CORES | | | NOT SHOWN | | | | | | 16) M2.05: INCOMPLETE RCP PLANS- THE AC DIFFUSERS AND | | | GRILLS ARE NOT LABELED IN THE ROOMS AND NO DIMENSIONS | | | ARE SHOWN. IDENTIFY ALL HP UNITS BEING SERVED BY THE | | | SUPPLY AND RETURN WATER PIPING TAGS SHOWN. F/S DAMPERS | | | MISSING AT THE NORTH CORE AC CLOSET AND AT WEST WALL OF | | | THE NORTH CORE BY CORRIDOR. | | | | | | 17) M2.17- M2.22: INCOMPLETE RCP PLANS- THE AC | | | DIFFUSERS AND GRILLS ARE NOT LABELED IN THE ROOMS AND | | | NO DIMENSIONS ARE SHOWN. IDENTIFY ALL HP UNITS BEING | | | SERVED BY THE SUPPLY AND RETURN WATER PIPING TAGS | | | SHOWN. F/S DAMPERS MISSING AT NORTH AND SOUTH CORES ON | | | M2.17- PLEASE CHECK ALL CORES ON ALL PLANS FOR MISSING | | | DAMPERS. | | | | | | 18) M2.23: INCOMPLETE RCP PLANS- THE AC DIFFUSERS AND | | | GRILLS ARE NOT LABELED IN THE ROOMS AND NO DIMENSIONS | | | ARE SHOWN. IDENTIFY ALL HP UNITS BEING SERVED BY THE | | | SUPPLY AND RETURN WATER PIPING TAGS SHOWN. THERE IS NO | | | FLOOR PLAN LAYOUT FOR THE SOUTH SIDE SHOWING ROOMS AND | | | SPACES. | | | | | | 19) M2.25 & M2.25: INCOMPLETE RCP PLANS- THE AC | | | DIFFUSERS AND GRILLS ARE NOT LABELED IN THE ROOMS AND | | | NO DIMENSIONS ARE SHOWN. IDENTIFY ALL HP UNITS BEING | | | SERVED BY THE SUPPLY AND RETURN WATER PIPING TAGS | | | SHOWN. | | | | | | 20) M2.26 & M2.27 | | | A) PROVIDE COMBUSTION AIR CALCULATIONS FOR THE BOILERS | | | AND INDICATE HOW THE AIR IS BEING PROVIDED- SEE SECTION | | | 304 FBC-10 FUEL GAS. | | | B) PROVIDE ENLARGED PLAN AND ELEVATION VIEWS OF THE | | | BOILERS AND HEAT EXCHANGERS INDICATING REQUIRED WORKING | | | CLEARANCES AND ID TAGS FOR ALL PARTS AND COMPONENTS. | | | C) PROVIDE BOILER VENTING PLANS AND DETAILS- INCLUDING | | | THE TYPES AND SIZES OF VENTS, LENGTH OF THE VENT RUNS, | | | AND TERMINATION LOCATIONS. | | | D) PROVIDE EOR REVIEWED AND APPROVED MANUFACTURER'S | | | SPECS AND SHOP DRAWINGS FOR ALL MECHANICAL EQUIPMENT ON | | | THE 26TH AND ROOF LEVELS INCLUDING THE BOILERS, HEAT | | | EXHANGERS, COOLING TOWERS, AND PUMPS. ALL EQUIPMENT | | | SHALL BE INCLUDED IN THE SUBMITTAL PACKAGE. | | | E) PROVIDE ENLARGED VIEWS OF THE COOLING TOWERS AND OAU | | | 1 & 2 SHOWING THE REQUIRED CLEARANCE DISTANCES FROM THE | | | FINISHED ROOF SURFACE TO THE BOTTOM OF THE UNITS. | | | F) REFER TO SECTION 301.12 AND PROVIDE WIND LOAD | | | ENGINEERING FOR TIE-DOWN OF ALL MECHANICAL EQUIPMENT | | | AND COMPONENTS EXPOSED TO WIND ON THE 26TH LEVEL AND | | | ROOF LEVELS OF THE BUILDING INCLUDING THE COOLING | | | TOWERS, OAU-1 & 2, THE PRESSURIZATIONS FANS, THE | | | EXHAUST FANS, THE SUPPLY AND EXHAUST DUCTWORK, PIPE AND | | | DUCT STANDS ETC. IF THESE DETAILS ARE PROVIDED ON THE | | | STRUCTURAL AND ARCHITECTURAL PLANS, PLEASE PROVIDE | | | NOTES INDICATING THE PLAN SHEETS. | | | G) PLEASE NOTE GUARDS AND PERMANENT LADDERS MAY BE | | | REQUIRED FOR SOME OF THE EQUIPMENT- REFER TO SECTIONS | | | 304.11 AND 306.5. | | | | | | 21) BASED ON THE PREVIOUS COMMENTS I HAVE PERFORMED | | | ONLY A CURSORY REVIEW OF THE RESIDENTIAL SUITE PLANS. | | | IT APPEARS THAT MANY OF THE ISSUES FOUND IN THE | | | REVIEWED PLANS ARE OCCURRING IN THOSE PLANS ALSO. AT | | | THIS TIME I AM CONCLUDING MY FIRST REVIEW OF THE PLANS | | | AND WILL LOOK FORWARD TO A SECOND REVIEW OF THE REVISED | | | AND CORRECTED PLANS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2017-02-06 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-02-06 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-02-06 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2017-02-06 16:48:54 | POOL PLANS APPROVED 2/6/17 BY GPJ |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2017-02-06 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-02-06 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-01-30 |
Time |
10:11 |
Sent To |
|
|
| Notes |
| 2017-02-06 15:48:39 | PLUMBING APPROVED WITH PROVISO | | | | | | 1. PROVIDE FLOOR PLANS P2-0P21, P2-01,P2-02, P2-03 WITH | | | ALL THE SANITARY RISERS CLEARLY LABELED TO MATCH | | | ISOMETRIC DRAWINGS. | | | | | | 2. SHTS. P5-03C,D,E PLEASE SHOW THE LEVELS ON THE | | | ISOMETRIC DRAWINGS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2016-12-29 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-12-29 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-12-03 |
Time |
08:57 |
Sent To |
|
|
| Notes |
| 2016-12-29 13:36:00 | 3RD REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: FROM 1ST REVIEW HAVE NOT BEEN FULLY | | | COMPLIED | | | | | | 41.PROVIDE MANUFACTURE SPEC SHEETS FOR ALL PUMPS | | | ,THERMOSTATIC MIXING VALVES, TANKS, WATER HEATERS ECT. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 THE DETAILLS ON THE | | | PLANS ARE NOT THE MANUFACTURE SPECIFICATION THESE CAN | | | BE A DEFERRED SUBMITTAL. | | | | | | 45.SHOW CONNECTION OF IRRIGATION SYSTEM ON WATER RISER | | | DIAGRAM. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 A BACK FLOW IS | | | REQUIRED | | | | | | 47.SHT.M4-02 NOTE ON GENERATOR DETAIL STATES THAT FUEL | | | PIPPING IS TO BE DONE BY ELECTRICAL CONTRACTOR. THAT IS | | | NOT IN THERE SCOPE OF REG ALLOWED BY THE STATE PLEASE | | | CLARIFY. SHEET HAS NOT BEEN REVISED | | | | | | 51.PROVIDE PROVIDE DETAILED PIPING RISER DIAGRAM FOR | | | DIESEL FUEL PIPING. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 PROVIDE SIZE AND | | | TYPE OF PIPING | | | | | | 2ND REVIEW COMMENTS: NOT COMPLIED | | | | | | 6. PROVIDE A NOTE FOR BACKFLOW ON POOL FILL. PER WPB | | | AMEND. TO FBC SEC. 107.2.1 | | | | | | 7. PLEASE PROVIDE PLUMBING FLOOR PLAN-FOR LEVEL 1 AND | | | 2-3 ASININITY'S WITH GRID LINES 9-17 . PER WPB AMEND. | | | TO FBC SEC. 107.2.1 SHT. P2-52B IS MISSING. | | | | | | 8. SHT. P5-28 THE HOT AND COLD WATER ISOMETRIC FOR SPA | | | IS MISSING THE 2 SHOWERS IN WOMENS SPA. PER WPB AMEND. | | | TO FBC SEC. 107.2.1 | | | | | | 9. SHT. P5-01+02 DOES NOT SHOW BRANCHES FOR AMENITY'S | | | AND GUEST SUITES PLEASE CLARIFY. PER WPB AMEND. TO FBC | | | SEC. 107.2.1 | | | | | | 12. PLEASE PROVIDE HOT AND COLD WATER ISOMETRICS FOR | | | UNITS ON LEVELS 18,19, PH 20,26 PER WPB AMEND. TO FBC | | | SEC. 107.2.1 A ISOMETRIC THAT IS SIMILAR DOES NOT | | | COMPLY ALL FIXTURES MUST BE SHOWN! | | | | | | 15. SHT. P5-27 ISOMETRIC FOR UNIT C IS MISSING THE | | | LAUNDRY SINK. PER WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | 16. SHT. P5-01 SHOW CONNECTION FOR TRASH SHOOT WASH | | | RING ON RISER. PER WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | 22. P5-23 SHOWS 12IN LINE FROM POOL DECK DRAINS SHT | | | P5-04 SHOWS 8IN CLARIFY. PER WPB AMEND. TO FBC SEC. | | | 107.2.1 | | | | | | | | | 27. SHT. P-28 SHOWS 2 SINKS NEXT TO WASHING MACHINES I | | | COULD NOT FIND THEM ON THE FLOOR PLAN. PER WPB AMEND. | | | TO FBC SEC. 107.2.1 SHOW ON PLUMBING FLOOR PLAN! | | | | | | 28. P5-06 LABEL RISER AN AND INDICATE LOCATION ON FLOOR | | | PLAN. PER WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | 29. P5-06 THRU 21 ISOMETRICS ARE UNCLEAR WHERE PIPES | | | CONNECT SOME PIPES DO NOT CONNECT . PROVIDE A CLEAR AND | | | CONCISE DRAWING SHOWING ALL PIPE SIZING AND VENT STACKS | | | VS SOIL STACKS , EXPAND THE ISOMETRICS LARGER SO | | | BATHROOM GROUPS DON'T RUN TOGETHER AND APPEAR TO | | | CONNECT.LABEL EACH ISOMETRIC WITH LOCATION OR FLOOR | | | LEVEL. PER WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | 3RD REVIEW: | | | | | | 1. SHT. P5-03D AND 03E LABEL LOCATION OF EACH ISOMETRIC | | | AND EXPAND EACH ISOMETRIC. PER WPB AMEND TO FBC 107.2.1 | | | | | | 2. SHT. A0-45 THE FLORIDA BUILDING ACCESSIBILITY CODE | | | SHOULD BE 2014 5TH EDITION NOT 2012 | | | | | | 3. SHT. A0-45B THE ACCESSIBLE SHOWERS SHALL COMPLY WITH | | | FBC ACC 608 IF YOUR GOING TO USE TH ALTERNATE ROLL IN | | | TYPE SHOWER COMPARTMENTS SHALL BE 36 INCHES WIDE EXACT. | | | THE WAY THEY ARE DESIGNED NOW IS NOT COMPLIANT. | | | | | | 4. SHT. A0-45B THE BATHROOM IN THE WOMENS SPA THE | | | CLEARANCE AROUND THE THE TOILET CAN NOT HAVE ANY THING | | | ELSE IN IT THE WING WALL ON THE RIGHT SIDE OF THE | | | TOILET DOES NOT COMPLY. PER FBC ACC 604.3.2 | | | | | | 5. PLEASE PROVIDE DETAILS FOR HIGHT DIMENSIONS FOR | | | ACCESSIBILITY IN COMMON AREAS. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 6. SHT. P5-03B S16 ON LEVEL 16 IS MISSING THE SHOWER IN | | | MASTER BATHROOM BETWEEN HIS AND HERS UNIT C. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | 7. SHT P5-03B S13 SHOWS A SHOWER THE FLOOR PLAN SHOWS A | | | T8UB PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 8. SHT. P2-54E-F THE WALLS AND FIXTURES DID NOT SHOW UP | | | PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 9. SHT. P5- 03B S10 SHOWS DOUBLE LAVS AND A SHOWER THE | | | FLOOR PLAN SHOWS A TUB AND A SINGLE LAV PLEASE CLARIFY. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | 10. SHT. P2-54C BATH 4 SHOWS ATUB S11 SHOWS A SHOWER | | | PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 11. SHT. P5 -11 RISER TAGS MISSING PLEASE CLARIFY. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | 12. SHT. P2-54C+ B REMOVE NOTE ON KITCHEN REFERRING TO | | | AAV IF A LOOP VENT IS BEING USED. PLEASE CLARIFY. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | 13. IF THE OIL SEPARATOR IS INSTALLED IN A PIT A DRAIN | | | IS REQUIRED. PER WPB AMEND TO FBC 107.2.1 | | | | | | 14. SHT. P5-01 ON LEVEL 3 THE RISER FOR HW-9 SHOWS 1" | | | THE DETAIL ON SHT. P5-28 SHOWS 11/2 FOR HW-9 + CW-9 . | | | PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 15. SHT.P5-01 + 02 THE BRANCHES FOR LEVELS 1,2,3 ARE | | | NOT SHOWN . PLEASE CLARIFY. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 16. SHT. P5-27 THE RISER DETAI FOR TYP. UNIT A 5-17 IS | | | MISSING BATH2 . PLEASE CLARIFY. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | IN ORDER TO EXPEDITE THIS PERMIT I WOULD ADVISE A | | | MEETING TO GO OVER COMMENT AND CLARIFY ANY ISSUES | | | PLEASE CONTACT ME. [email protected] OR 561-805-6711 | | | | | | DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND | | | THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON | | | RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS. | | | | | | | | | | | | | | | | | | POOL COMMENTS: | | | | | | 1. POOL ,HOT SPA POOL , HIS AND HER JACUZZIS AND ALL | | | WATER FEATURES REQUIRE SEPARATE PERMIT FROM MAIN | | | BUILDING.\ | | | 2. SHALL OBTAIN OPERATING PERMIT FROM PALM BEACH COUNTY | | | HEALTH DEPARTMENT. SHOW NOTE ON PLAN | | | PER FBC SEC. 454 | | | NOTE: OTHER ADMINISTRATIVE AND PROGRAMMATIC PROVISIONS | | | APPLY. SEE DEPARTMENT OF HEALTH (DOH) RULE 64E-9, | | | FLORIDA ADMINISTRATIVE CODE AND CHAPTER 514, FLORIDA | | | STATUTES. THE REGULATION AND ENFORCEMENT OF THE INITIAL | | | AND ANNUAL OPERATION PERMIT FOR PUBLIC POOLS ARE | | | PREEMPTED TO THE DOH. THE CONSTRUCTION PERMIT HOLDER IS | | | RESPONSIBLE FOR OBTAINING AN OPERATION PERMIT ISSUED BY | | | DOH, AS A PUBLIC SWIMMING POOL SHALL NOT BE PUT INTO | | | OPERATION WITHOUT AN INSPECTION AND OPERATION PERMIT | | | ISSUED FROM THE DOH. DOH MAY GRANT VARIANCES FROM THE | | | PROVISIONS OF THE FLORIDA BUILDING CODE SPECIFICALLY | | | PERTAINING TO PUBLIC SWIMMING POOLS AND BATHING PLACES | | | AS AUTHORIZED BY SECTION 514.0115, FLORIDA STATUTES. | | | BUILDING OFFICIALS SHALL RECOGNIZE AND ENFORCE VARIANCE | | | ORDERS ISSUED BY THE DEPARTMENT OF HEALTH PURSUANT TO | | | SECTION 514.0115(5), FLORIDA STATUTES INCLUDING ANY | | | CONDITIONS ATTACHED TO THE GRANTING OF THE VARIANCE. | | | | | | | | | 14. ONE URINAL IS REQUIRED IN MEN?S POOL BATHROOM. PER | | | FBC PL TABLE 403.6 AND SEC 403.6 SHT. A2.52B DOES NOT | | | SHOW URINAL IN MENS BATHROOM. | | | | | | 18. SHOW COMPLIANCE FOR OZONE EQUIPMENT ROOM | | | VENTILATION MUST COMPLY WITH FBC SEC. 545.1.6.5.16.4.5 | | | PLEASE PROVIDE SHT. NUMBERS | | | | | | 24. PROVIDE MSDS SHEETS FOR ALL CHEMICALS USED. PER WPB | | | AMEND. TO FBC 107.2. | | | | | | 28. OZONE GENERATING EQUIPMENT ELECTRICAL COMPONENTS | | | AND WIRING SHALL COMPLY WITH THE REQUIREMENTS OF | | | CHAPTER 27 OF THIS CODE AND THE MANUFACTURER SHALL | | | PROVIDE A CERTIFICATE OF CONFORMANCE. THE PROCESS | | | EQUIPMENT SHALL BE PROVIDED WITH AN EFFECTIVE MEANS TO | | | ALERT THE USER WHEN A COMPONENT OF THIS EQUIPMENT IS | | | NOT OPERATING PER FBC 454.1.6.5.16.4.1 SHOW NOTE ON | | | PLAN | | | | | | 29. PROVIDE SPECS FOR CHANNEL DRAINS FOR SPAL. PER WPB | | | AMEND. TO FBC SEC. 107.2.1 | | | | | | NEW COMMENTS | | | | | | 1. FOR THE TRANSFER WALL AT HOT SPA SHOW COMPLIANCE | | | WITH FBC ACC (A) 1009.4.1 CLEAR DECK SPACE. | | | A CLEAR DECK SPACE OF 60 INCHES (1525 MM) MINIMUM BY 60 | | | INCHES (1525 MM) MINIMUM WITH A SLOPE NOT STEEPER THAN | | | 1:48 SHALL BE PROVIDED AT THE BASE OF THE TRANSFER | | | WALL. WHERE ONE GRAB BAR IS PROVIDED, THE CLEAR DECK | | | SPACE SHALL BE CENTERED ON THE GRAB BAR. WHERE TWO GRAB | | | BARS ARE PROVIDED, THE CLEAR DECK SPACE SHALL BE | | | CENTERED ON THE CLEARANCE BETWEEN THE GRAB BARS. | | | (B)1009.4.2 HEIGHT. | | | THE HEIGHT OF THE TRANSFER WALL SHALL BE 16 INCHES (405 | | | MM) MINIMUM AND 19 INCHES (485 MM) MAXIMUM MEASURED | | | FROM THE DECK. | | | (C)1009.4.5 GRAB BARS. | | | AT LEAST ONE GRAB BAR COMPLYING WITH 609 SHALL BE | | | PROVIDED ON THE TRANSFER WALL. GRAB BARS SHALL BE | | | PERPENDICULAR TO THE POOL WALL AND SHALL EXTEND THE | | | FULL DEPTH OF THE TRANSFER WALL. THE TOP OF THE | | | GRIPPING SURFACE SHALL BE 4 INCHES (100 MM) MINIMUM AND | | | 6 INCHES (150 MM) MAXIMUM ABOVE TRANSFER WALLS. WHERE | | | ONE GRAB BAR IS PROVIDED, CLEARANCE SHALL BE 24 INCHES | | | (610 MM) MINIMUM ON BOTH SIDES OF THE GRAB BAR. WHERE | | | TWO GRAB BARS ARE PROVIDED, CLEARANCE BETWEEN GRAB BARS | | | SHALL BE 24 INCHES (610 MM) MINIMUM. | | | | | | 2. DETAILS NOT SHOWN FOR BACKFLOW /AIR GAP ON FILL | | | LINES AND OVER FLOW FILL LINE BOX FOR WATER FEATURE. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | 3. THE CRYSTAL FOUNTAIN SHOWS AN OVERFLOW CONNECTING TO | | | A SEWER YOU SHALL RECEIVE APPROVAL FROM ENGINEERING | | | DEPARTMENT TO CONNECT ANY OVERFLOW FROM WATER FEATURES | | | OR POOL EQUIPMENT CONTACT MANUEL GONZALEZ 561-494-1085 | | | | | | | | | | | | | | | | | | | | | | | | DO TO THE DEFICIENCY'S AND SOME SHEETS BEING UNCLEAR A | | | COMPLETE AND COMPREHENSIVE REVIEW OF THE PLUMBING | | | SYSTEMS CAN NOT BE COMPLETED AT THIS TIME. THIS MAY | | | GENERATE MORE COMMENTS UPON SECOND REVIEW. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2016-08-31 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-08-31 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-08-01 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2016-08-11 08:55:42 | 2ND REVIEW | | | | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | | | | PLUMBING COMMENTS: | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: FROM 1ST REVIEW HAVE NOT BEEN FULLY | | | COMPLIED | | | | | | 1. SHT. A6-70F DETAIL 3 IS CALLING OUT BATH 2 FOR SPEC | | | B FHA, DETAIL 2 IS CALLING OUT BATH 2 AS STANDARD ,IT | | | APPEARS TO BE A TYPO PLEASE CLARIFY. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 2. SHOLL WHICH BATHROOM IS DESIGNATED FOR FHA UNIT | | | 21A-21B. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | | | | 5. SHOW ACCESSIBILITY LEVEL FOR AMENITY BATH ROOMS ON | | | LEVEL 1-3. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | 11. SHT. P5-01 SHOWS 6IN. CW RISER RUNNING UP FROM | | | PUMPS TO BLADDER TANKS WHERE DOES IT CONNECT WITH THE | | | REST OF THE WATER RISER PLEASE CLARIFY. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | 14.INDICATE DIRECTION OF FLOW MORE CLEARLY ON HOT WATER | | | RECIRCULATION SYSTEM. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | 16.SHT. P5-13 SHOWS S-13A NOT SHOWN ON P5-05 PLEASE | | | CLARIFY. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | | | | 31. SHT.P2-01 DD-2 BETWEEN LINES 1-2 AND A-D IS MISSING | | | ON RISER DIAGRAM ON SHT. P5-24 ALSO MISSING PD BETWEEN | | | LINES 1-2 A-D. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | 34.SHT. C3-01 SHOWS EXISTING SEWER TO BE USED AS DRAIN | | | FOR FOUNTAIN. WATER FROM FOUNTAIN POOLS AND WATER | | | FEATURES SHALL NOT DRAIN INTO SANITARY PER. WPB ORD. | | | SEC. 90-126.(5) | | | 35. PROVIDE CALCULATIONS FOR STORM SUMP PUMP AND OIL | | | SAND SEPARATORS. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 36. SHT. P5-24 SHORT TRENCH DRAINS MISSING SQ FT CALC . | | | PLEASE PROVIDE. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | 39. PROVIDE MANUFACTURE SECS FOR OIL SAND SEPARATOR. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | 41.PROVIDE MANUFACTURE SPEC SHEETS FOR ALL PUMPS | | | ,THERMOSTATIC MIXING VALVES, TANKS, WATER HEATERS ECT. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | 45.SHOW CONNECTION OF IRRIGATION SYSTEM ON WATER RISER | | | DIAGRAM. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 46. SEPARATE PERMITS REQUIRED FOR BACKFLOW PREVENTER'S | | | AT METERS. FOR IRRIGATION, DOMESTIC, AND COOLING TOWERS | | | POOL FILL,FIRE | | | 47.SHT.M4-02 NOTE ON GENERATOR DETAIL STATES THAT FUEL | | | PIPPING IS TO BE DONE BY ELECTRICAL CONTRACTOR. THAT IS | | | NOT IN THERE SCOPE OF REG ALLOWED BY THE STATE PLEASE | | | CLARIFY. | | | | | | 51.PROVIDE PROVIDE DETAILED PIPING RISER DIAGRAM FOR | | | DIESEL FUEL PIPING. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 52. WHERE DOES THE SUMP DRAINS ON FUEL PUMPS DISCHARGE | | | TO. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | IN YOUR RESPONSE LETTER MANY OF YOUR NARRATIVES JUST | | | SAY REFER TO REVISED SHEET THIS DOES NOT GIVE ME MUCH | | | INFORMATION. IF YOU COULD REFERENCE A SPECIFIC SHEET IT | | | WOULD GREATLY EXPEDITE MY PLAN REVIEW PROCESS AND BE | | | GREATLY APPRECIATED THANK YOU. | | | | | | | | | 2ND REVIEW COMMENTS: | | | | | | 1. IN REFERENCE TO PREVIOUS COMMENT #5 PLEASE PROVIDE | | | DETAILS SHOWING COMPLIANCE WITH TH E FBC ACC. SHOW ALL | | | THE HEIGHTS OF GRAB BARS, TOILET SEATS, LAVATORY'S, | | | MIRRORS, TOILET PAPER DISPENSERS, SHOWER CONTROL | | | LOCATIONS AND SHOWER SEATS, DRINKING FOUNTAIN SHOW | | | CLEAR FLOOR SPACE FOR ALL FIXTURES. PER WPB AMEND. TO | | | FBC SEC. 107.2.1 | | | | | | 2. SHT. A2-52A SHOW INSIDE DIMENSIONS OF BATHROOMS | | | 207-205. PER WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | 3. BATHROOMS NEXT TO JACUZZI IN MENS AND WOMENS SPA | | | SHALL BE ACCESSIBLE.PER FBC ACC. 213.2 | | | | | | 4. USING YOUR OCCUPANT TYPE AND LOAD FROM SHT. A0-32 I | | | HAVE DETERMINED THAT ON THE 1ST LEVEL ( LOBBY) IT IS | | | REQUIRED TO HAVE 4 WATER CLOSETS FOR THE MEN AND 4 FOR | | | THE WOMEN 6 LAVS 2 DRINKING FOUNTAINS AND 1 SERVICE | | | SINK . IT APPEARS THAT YOU ARE SHORT 3 WATER CLOSETS 5 | | | LAVS PER SEX AND 2 DRINKING FOUNTAIN AND 1 SERVICE | | | SINK. PER FBC PL TABLE 403.1 | | | | | | 5. 4. USING YOUR OCCUPANT TYPE AND LOAD FROM SHT. A0-33 | | | I HAVE DETERMINED THAT ON THE 2ND LEVEL (AMENITY'S) IT | | | IS REQUIRED TO HAVE 3 WATER CLOSETS FOR THE MEN AND 4 | | | FOR THE WOMEN 2 LAVS PER SEX 2 DRINKING FOUNTAINS AND 1 | | | SERVICE SINK . IT APPEARS THAT YOU ARE SHORT 1 WATER | | | CLOSET-FOR THE WOMEN 2 DRINKING FOUNTAIN AND 1 SERVICE | | | SINK. PER FBC PL TABLE 403.1 | | | | | | 6. PROVIDE A NOTE FOR BACKFLOW ON POOL FILL. PER WPB | | | AMEND. TO FBC SEC. 107.2.1 | | | | | | 7. PLEASE PROVIDE PLUMBING FLOOR PLAN-FOR LEVEL 1 AND | | | 2-3 ASININITY'S WITH GRID LINES 9-17 . PER WPB AMEND. | | | TO FBC SEC. 107.2.1 | | | | | | 8. SHT. P5-28 THE HOT AND COLD WATER ISOMETRIC FOR SPA | | | IS MISSING THE 2 SHOWERS IN WOMENS SPA. PER WPB AMEND. | | | TO FBC SEC. 107.2.1 | | | | | | 9. SHT. P5-01+02 DOES NOT SHOW BRANCHES FOR AMENITY'S | | | AND GUEST SUITES PLEASE CLARIFY. PER WPB AMEND. TO FBC | | | SEC. 107.2.1 | | | | | | 10. SHT. P5-27 ISOMETRICS FOR UNITS 3,7,11 ARE MISSING | | | THE WATER CLOSET AND LAVATORY'S. PER WPB AMEND. TO FBC | | | SEC. 107.2.1 | | | | | | 11. SHT. P5-27 THE PIPE SIZING IS TO LITE TO BE EASILY | | | READ PLEASE CHECK ALL SHEETS AND CORRECT. PER WPB | | | AMEND. TO FBC SEC. 107.2.1 | | | | | | 12. PLEASE PROVIDE HOT AND COLD WATER ISOMETRICS FOR | | | UNITS ON LEVELS 18,19, PH 20,26 PER WPB AMEND. TO FBC | | | SEC. 107.2.1 | | | | | | 13. SHT. P5-27 ISOMETRIC FOR UNIT A IS MISSING THE TUB | | | IN THE BATHROOM AT GRID LINES S+6 ON SHT. P2-54C. PER | | | WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | 13 SHT P5-27 THE ISOMETRIC FOR UNIT B IS MISSING THE | | | LAV IN THE BATHROOM AT GRID LINES P-8.5 ON SHT P2-54C. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | 14. SHT.P5-27 THE BATHROOM ON GRID LINES P.5-6 ON SHT | | | P2-54C IS SHOWN AS A SHOWER ON THE ISOMETRIC AND A TUB | | | ON THE FLOOR PLAN PLEASE CLARIFY. PER WPB AMEND. TO FBC | | | SEC. 107.2.1 | | | | | | 15. SHT. P5-27 ISOMETRIC FOR UNIT C IS MISSING THE | | | LAUNDRY SINK. PER WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | 16. SHT. P5-01 SHOW CONNECTION FOR TRASH SHOOT WASH | | | RING ON RISER. PER WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | 17. SHT. P5-01 AT THE MECHANICAL LEVEL IT SHOWS THE 4IN | | | AND 6IN CW CONNECTING TOGETHER CONNECTING TWICE PROVIDE | | | A RISER THAT CLEARLY SHOWS WHERE PIPES CONNECT AND | | | WHERE THEY CROSS. PER WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | 18. UNABLE TO LOCATE SANITARY RISER FROM LEVEL 16 DOWN. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | 19. SHT P5-06 LABEL STACKS AND INDICATE ON THE DRAWING | | | FLOOR LEVEL . PER WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | 20. SHT P5-03-10 FIXTURE LAYOUT AND PIPE SIZING DO NOT | | | MATCHISOMETRCS ON P5-10 THEYE UNCLEAR AND DON'T SEAM TO | | | BE COMPLETE SOME OF THE BRANCHES SEAM TO CONNECT AT TWO | | | DIFFERENT STACKS SOME STACKS DON'T CONNECT ANY WHERE. | | | PLEASE CLARIFY. PER WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | 21. PLEASE LABEL STORM RISERS ON THE ISOMETRIC DRAWINGS | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | 22. P5-23 SHOWS 12IN LINE FROM POOL DECK DRAINS SHT | | | P5-04 SHOWS 8IN CLARIFY. PER WPB AMEND. TO FBC SEC. | | | 107.2.1 | | | | | | 23. SHT- 23 DETAIL #2 I WAS UNABLE TO LOCATE THESE | | | DRAINS ON FOR PLANS LABEL WITH LOCATION. PER WPB AMEND. | | | TO FBC SEC. 107.2.1 | | | | | | 24. SHT P5-04 PROVIDE SQFT ON RISERS. PER WPB AMEND. TO | | | FBC SEC. 107.2.1 | | | | | | 25. SHT. P5-21 INDICATE ON PLAN AT WHAT PITCH THE | | | PIPING WILL BE INSTALLED AND-SHOW SQFT ON EACH SECTION | | | OF PIPE. PER WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | 26. SHT. P5-21 THE ISOMETRIC FOR RD 11,19,20,21IT IS | | | UNCLEAR HOW OR WHERE TO THE RISERS. PER WPB AMEND. TO | | | FBC SEC. 107.2 | | | | | | 27. SHT. P-28 SHOWS 2 SINKS NEXT TO WASHING MACHINES I | | | COULD NOT FIND THEM ON THE FLOOR PLAN. PER WPB AMEND. | | | TO FBC SEC. 107.2.1 | | | | | | 28. P5-06 LABEL RISER AN AND INDICATE LOCATION ON FLOOR | | | PLAN. PER WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | 29. P5-07THRU21 ISOMETRICS ARE UNCLEAR WHERE PIPES | | | CONNECT SOME PIPES DO NOT CONNECT . PROVIDE A CLEAR AND | | | CONCISE DRAWING SHOWING ALL PIPE SIZING AND VENT STACKS | | | VS SOIL STACKS , YOU MAY HAVE TO EXPAND THE ISOMETRICS | | | LARGER SO BATHROOM GROUPS DON'T RUN TOGETHER AND APPEAR | | | TO CONNECT. PER WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | | | | IN YOUR RESPONSE LETTER MANY OF YOUR NARRATIVES JUST | | | SAY REFER TO REVISED SHEET THIS DOES NOT GIVE ME MUCH | | | INFORMATION. IF YOU COULD REFERENCE A SPECIFIC SHEET IT | | | WOULD GREATLY EXPEDITE MY PLAN REVIEW PROCESS AND BE | | | GREATLY APPRECIATED THANK YOU. | | | | | | DUE TO THE DEFICIENCIES OF THIS PLAN A COMPLETE AND | | | THOROUGH REVIEW CANNOT BE DONE AT THIS TIME. UPON | | | RESUBMITTAL THERE MAYBE ADDITIONAL COMMENTS. | | | | | | | | | | | | | | | | | | POOL COMMENTS: | | | | | | 1. POOL ,HOT SPA POOL , HIS AND HER JACUZZIS AND ALL | | | WATER FEATURES REQUIRE SEPARATE PERMIT FROM MAIN | | | BUILDING.\ | | | 2. SHALL OBTAIN OPERATING PERMIT FROM PALM BEACH COUNTY | | | HEALTH DEPARTMENT. SHOW NOTE ON PLAN | | | PER FBC SEC. 454 | | | NOTE: OTHER ADMINISTRATIVE AND PROGRAMMATIC PROVISIONS | | | APPLY. SEE DEPARTMENT OF HEALTH (DOH) RULE 64E-9, | | | FLORIDA ADMINISTRATIVE CODE AND CHAPTER 514, FLORIDA | | | STATUTES. THE REGULATION AND ENFORCEMENT OF THE INITIAL | | | AND ANNUAL OPERATION PERMIT FOR PUBLIC POOLS ARE | | | PREEMPTED TO THE DOH. THE CONSTRUCTION PERMIT HOLDER IS | | | RESPONSIBLE FOR OBTAINING AN OPERATION PERMIT ISSUED BY | | | DOH, AS A PUBLIC SWIMMING POOL SHALL NOT BE PUT INTO | | | OPERATION WITHOUT AN INSPECTION AND OPERATION PERMIT | | | ISSUED FROM THE DOH. DOH MAY GRANT VARIANCES FROM THE | | | PROVISIONS OF THE FLORIDA BUILDING CODE SPECIFICALLY | | | PERTAINING TO PUBLIC SWIMMING POOLS AND BATHING PLACES | | | AS AUTHORIZED BY SECTION 514.0115, FLORIDA STATUTES. | | | BUILDING OFFICIALS SHALL RECOGNIZE AND ENFORCE VARIANCE | | | ORDERS ISSUED BY THE DEPARTMENT OF HEALTH PURSUANT TO | | | SECTION 514.0115(5), FLORIDA STATUTES INCLUDING ANY | | | CONDITIONS ATTACHED TO THE GRANTING OF THE VARIANCE. | | | | | | | | | 14. ONE URINAL IS REQUIRED IN MEN?S POOL BATHROOM. PER | | | FBC PL TABLE 403.6 AND SEC 403.6 SHT. A2.52B DOES NOT | | | SHOW URINAL IN MENS BATHROOM. | | | | | | 18. SHOW COMPLIANCE FOR OZONE EQUIPMENT ROOM | | | VENTILATION MUST COMPLY WITH FBC SEC. 545.1.6.5.16.4.5 | | | PLEASE PROVIDE SHT. NUMBERS | | | | | | 24. PROVIDE MSDS SHEETS FOR ALL CHEMICALS USED. PER WPB | | | AMEND. TO FBC 107.2. | | | | | | 28. OZONE GENERATING EQUIPMENT ELECTRICAL COMPONENTS | | | AND WIRING SHALL COMPLY WITH THE REQUIREMENTS OF | | | CHAPTER 27 OF THIS CODE AND THE MANUFACTURER SHALL | | | PROVIDE A CERTIFICATE OF CONFORMANCE. THE PROCESS | | | EQUIPMENT SHALL BE PROVIDED WITH AN EFFECTIVE MEANS TO | | | ALERT THE USER WHEN A COMPONENT OF THIS EQUIPMENT IS | | | NOT OPERATING PER FBC 454.1.6.5.16.4.1 SHOW NOTE ON | | | PLAN | | | | | | 29. PROVIDE SPECS FOR CHANNEL DRAINS FOR SPAL. PER WPB | | | AMEND. TO FBC SEC. 107.2.1 | | | | | | NEW COMMENTS | | | | | | 1. FOR THE TRANSFER WALL AT HOT SPA SHOW COMPLIANCE | | | WITH FBC ACC (A) 1009.4.1 CLEAR DECK SPACE. | | | A CLEAR DECK SPACE OF 60 INCHES (1525 MM) MINIMUM BY 60 | | | INCHES (1525 MM) MINIMUM WITH A SLOPE NOT STEEPER THAN | | | 1:48 SHALL BE PROVIDED AT THE BASE OF THE TRANSFER | | | WALL. WHERE ONE GRAB BAR IS PROVIDED, THE CLEAR DECK | | | SPACE SHALL BE CENTERED ON THE GRAB BAR. WHERE TWO GRAB | | | BARS ARE PROVIDED, THE CLEAR DECK SPACE SHALL BE | | | CENTERED ON THE CLEARANCE BETWEEN THE GRAB BARS. | | | (B)1009.4.2 HEIGHT. | | | THE HEIGHT OF THE TRANSFER WALL SHALL BE 16 INCHES (405 | | | MM) MINIMUM AND 19 INCHES (485 MM) MAXIMUM MEASURED | | | FROM THE DECK. | | | (C)1009.4.5 GRAB BARS. | | | AT LEAST ONE GRAB BAR COMPLYING WITH 609 SHALL BE | | | PROVIDED ON THE TRANSFER WALL. GRAB BARS SHALL BE | | | PERPENDICULAR TO THE POOL WALL AND SHALL EXTEND THE | | | FULL DEPTH OF THE TRANSFER WALL. THE TOP OF THE | | | GRIPPING SURFACE SHALL BE 4 INCHES (100 MM) MINIMUM AND | | | 6 INCHES (150 MM) MAXIMUM ABOVE TRANSFER WALLS. WHERE | | | ONE GRAB BAR IS PROVIDED, CLEARANCE SHALL BE 24 INCHES | | | (610 MM) MINIMUM ON BOTH SIDES OF THE GRAB BAR. WHERE | | | TWO GRAB BARS ARE PROVIDED, CLEARANCE BETWEEN GRAB BARS | | | SHALL BE 24 INCHES (610 MM) MINIMUM. | | | | | | 2. DETAILS NOT SHOWN FOR BACKFLOW /AIR GAP ON FILL | | | LINES AND OVER FLOW FILL LINE BOX FOR WATER FEATURE. | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | 3. THE CRYSTAL FOUNTAIN SHOWS AN OVERFLOW CONNECTING TO | | | A SEWER YOU SHALL RECEIVE APPROVAL FROM ENGINEERING | | | DEPARTMENT TO CONNECT ANY OVERFLOW FROM WATER FEATURES | | | OR POOL EQUIPMENT CONTACT MANUEL GONZALEZ 561-494-1085 | | | | | | | | | | | | | | | | | | | | | | | | DO TO THE DEFICIENCY'S AND SOME SHEETS BEING UNCLEAR A | | | COMPLETE AND COMPREHENSIVE REVIEW OF THE PLUMBING | | | SYSTEMS CAN NOT BE COMPLETED AT THIS TIME. THIS MAY | | | GENERATE MORE COMMENTS UPON SECOND REVIEW. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2016-02-02 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2016-01-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2016-01-28 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2016-02-01 14:58:47 | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHT. A6-70F DETAIL 3 IS CALLING OUT BATH 2 FOR SPEC | | | B FHA, DETAIL 2 IS CALLING OUT BATH 2 AS STANDARD ,IT | | | APPEARS TO BE A TYPO PLEASE CLARIFY. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 2. SHOLL WHICH BATHROOM IS DESIGNATED FOR FHA UNIT | | | 21A-21B. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 3.SHT. A2-75A REFERS TO A2-60A THEY DO NOT MATCH PLEASE | | | CLARIFY. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 4.SHOW HEIGHT OF SINK IN ADMINISTRATION OFFICE TO | | | COMPLY WITH FBC ACC. SEC. 606.3 | | | 5. SHOW ACCESSIBILITY LEVEL FOR AMENITY BATH ROOMS ON | | | LEVEL 1-3. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 6. SHT. P5-01 AND P5-01 THE LINES FOR FLOOR LEVELS AND | | | WATER PIPES LOOK THE SAME. PROVIDE CLEAR ISOMETRIC | | | WATER RISER DIAGRAM. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 7. PROVIDE AN EXPANDED ISOMETRIC HOT AND COLD WATER | | | RISER DIAGRAM FOR UNITS AND AMENITYS AND GUEST SUITES. | | | PER WPB AMEND. TO FBC SEC. 107.2. | | | 8.LABEL WATER RISERS TO COINCIDE WITH UNIT DESIGNATION. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 9. WATER HAMMER ARRESTOR REQUIRED FOR TRASH SHUTE FLUSH | | | RING TO COMPLY WITH FBC PL.SEC. 604.9 | | | 10. PROVIDE ISOMETRIC FOR COOLING TOWER FILL PIPING. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 11. SHT. P5-01 SHOWS 6IN. CW RISER RUNNING UP FROM | | | PUMPS TO BLADDER TANKS WHERE DOES IT CONNETC WITH THE | | | REST OF THE WATER RISER PLEASE CLARIFY. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 12. PROVIDE HOT WATER ISOMETRIC.RISER DIAGRAM. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 13. SIZE ALL SECTIONS OF PIPE ON HOT AND COLD ISOMETRIC | | | RISER DIAGRAM. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 14.INDICATE DIRECTION OF FLOW MORE CLEARLY ON HOT WATER | | | RECIRCULATION SYSTEM. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 15. PLEASE PROVIDE ISOMETRIC RISER DIAGRAM FOR SANITARY | | | SHT.P5-03 | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 16.SHT. P5-13 SHOWS S-13A NOT SHOWN ON P5-05 PLEASE | | | CLARIFY. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 17.AAV. ARE NOT ALLOWED BELOW FOURTH BRANCH INTERVAL | | | DOWN FROM THE TOP OF THE STACK. SHALL COMPLY WITH. FBC | | | PL. SEC.918.3.1 | | | | | | 18. PLEASE LABEL ALL STACKS TO MATCH | | | .PER WPB AMEND. TO FBC SEC. 107.2. | | | 19. PROVIDE EXPANDED ISOMETRIC DRAWINGS FOR ALL | | | DWELLING UNITS AND AMENITY'S ONES PROVIDED ARE TO | | | COMPACK. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 20. INDICATE BATHROOM # ON SANITARY ISOMETRIC DETAILS. | | | PER WPB AMEND. TO FBC SEC. 107.2. | | | 21.SHT P5.06 DOES NOT MATCH PLEASE CLARIFY. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 22.SHT P5-03 SHOW ALL STACKS MISSING | | | S3/S6-8/S11/S14-16/S18-19/S21-15/S28-30. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 23. FIXTURE DRAINS FOR WASHING MACHINE SHALL BE 3IN. | | | PER FBC PL.SEC.406.2 | | | 24.SHT. P5-20 SHOW TRAP PRIMERS ON ALL FLOOR DRAINS AND | | | HUB DRAINS. | | | SHALL COMPLY WITH FBC PL.SEC. 1002.4 | | | 25.PROVIDE FLOOR PLAN WITH PLUMBING FOR MECHANICAL ROOM | | | AND ISOMETRIC. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 26.ALL VENTS THROUGH ROOF SHALL BE A MINIMUM OF 10FT | | | AWAY FROM ANY AIR INTAKE. | | | SHALL COMPLY WITH FBC PL. SEC.903.5 | | | 27. P5-04 PROVIDE ISOMETRIC RISER DIAGRAM SHALL ALL | | | RWL. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 28. MISSING RD1-2 ON RISER DIAGRAM SHT. P5-21 ,BETWEEN | | | LINES Q+S/11+12 ON SHT.P2-26. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 29. SHT. P5-04 SHOW ALL RWL WITH SIZE AND SQ FT | | | DRAINED. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 30.SHT. P5-23 DETAIL #2 LOCATION CLARIFY | | | LOCATION,CLARIFY NOTE *IN RWL FOR OVERFLOW. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 31. SHT.P2-01 DD-2 BETWEEN LINES 1-2 AND A-D IS MISSING | | | ON RISER DIAGRAM ON SHT. P5-24 ALSO MISSING PD BETWEEN | | | LINES 1-2 A-D. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 32.SHT. P5-24 DETAIL #1 LABEL LOCATION. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 33. LABEL WITH LOCATION ALL DD+PD+AD ON RISER DIAGRAM | | | AND PLUMBING FLOOR PLAN. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 34.SHT. C3-01 SHOWS EXISTING SEWER TO BE USED AS DRAIN | | | FOR FOUNTAIN. WATER FROM FOUNTAIN POOLS AND WATER | | | FEATURES SHALL NOT DRAIN INTO SANITARY PER. WPB ORD. | | | SEC. 90-126.(5) | | | 35. PROVIDE CALCULATIONS FOR STORM SUMP PUMP AND OIL | | | SAND SEPARATORS. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 36. SHT. P5-24 SHORT TRENCH DRAINS MISSING SQ FT CALC . | | | PLEASE PROVIDE. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 37. ALL OVER FLOW DRAINS MUST BE SIZED SAME AS MAIN | | | DRAINS SHALL COMPLY WITH FBC PL. SEC. 1108.3 | | | 38. PLEASE REMOVE ALL UNUSED DETAIL FROM PLUMBING | | | DETAIL SHEETS. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 39. PROVIDE MANUFACTURE SECS FOR OIL SAND SEPARATOR. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 40. SHT. P4-06 DETAIL #3 IS THIS THE OIL SAND SEPARATOR | | | YOU ARE USING PLEASE CLARIFY. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 41.PROVIDE MANUFACTURE SPEC SHEETS FOR ALL PUMPS | | | ,THERMOSTATIC MIXING VALVES, TANKS, WATER HEATERS ECT. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 42. CLEAN OUTS REQUIRED AT THE BASE OF ALL STACKS SHOW | | | COMPLIANCE WITH. FBC PL SEC. 708.3.4 | | | 43. SHT.P5-20 + P2-26 IT APPEARS THAT YOU ARE DRAINING | | | THE CONDENSATE OR COOLING WATER INTO THE SANITARY | | | SYSTEM . CONDENSATE AND COOLING TOWER WATER MUST DRAIN | | | INTO STORM AND BE INCLUDED IN SIZING CALCULATIONS. | | | PER. WPB ORD. SEC. 90-126(5) | | | 44. PROVIDE COMPLETE CONDENSATE RISER DIAGRAM WITH | | | SIZING CALCULATIONS. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 45.SHOW CONNECTION OF IRRIGATION SYSTEM ON WATER RISER | | | DIAGRAM. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 46. SEPARATE PERMITS REQUIRED FOR BACKFLOW PREVENTER'S | | | AT METERS. FOR IRRIGATION, DOMESTIC, AND COOLING TOWERS | | | POOL FILL,FIRE | | | 47.SHT.M4-02 NOTE ON GENERATOR DETAIL STATES THAT FUEL | | | PIPPING IS TO BE DONE BY ELECTRICAL CONTRACTOR. THAT IS | | | NOT IN THERE SCOPE OF REG ALLOWED BY THE STATE PLEASE | | | CLARIFY. | | | 48. SHT. M4-04 DETAIL FOR AIR SEPARATOR, EXPANSION TANK | | | SHOWS CONNECTION TO WATER SUPPLY PLEASE CLARIFY WHAT | | | THIS SYSTEM IS FOR. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 49. PROVIDE MANUFACTURE SPEC SHEETS FOR GENERATOR. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 50. PLEASE PROVIDE MSDS SHEETS FOR DIESEL FUEL. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 51.PROVIDE PROVIDE DETAILED PIPING RISER DIAGRAM FOR | | | DIESEL FUEL PIPING. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 52. WHERE DOES THE SUMP DRAINS ON FUEL PUMPS DISCHARGE | | | TO. | | | PER WPB AMEND. TO FBC SEC. 107.2.1 | | | | | | DO TO THE DEFICIENCY'S AND SOME SHEETS BEING UNCLEAR A | | | COMPLETE AND COMPREHENSIVE REVIEW OF THE PLUMBING | | | SYSTEMS CAN NOT BE COMPLETED AT THIS TIME. THIS MAY | | | GENERATE MORE COMMENTS UPON SECOND REVIEW. | | | | | | POOL COMMENTS: | | | | | | 1. POOL ,HOT SPA POOL , HIS AND HER JACUZZIS AND ALL | | | WATER FEATURES REQUIRE SEPARATE PERMIT FROM MAIN | | | BUILDING.\ | | | 2. SHALL OBTAIN OPERATING PERMIT FROM PALM BEACH COUNTY | | | HEALTH DEPARTMENT. | | | PER FBC SEC. 454 | | | NOTE: OTHER ADMINISTRATIVE AND PROGRAMMATIC PROVISIONS | | | APPLY. SEE DEPARTMENT OF HEALTH (DOH) RULE 64E-9, | | | FLORIDA ADMINISTRATIVE CODE AND CHAPTER 514, FLORIDA | | | STATUTES. THE REGULATION AND ENFORCEMENT OF THE INITIAL | | | AND ANNUAL OPERATION PERMIT FOR PUBLIC POOLS ARE | | | PREEMPTED TO THE DOH. THE CONSTRUCTION PERMIT HOLDER IS | | | RESPONSIBLE FOR OBTAINING AN OPERATION PERMIT ISSUED BY | | | DOH, AS A PUBLIC SWIMMING POOL SHALL NOT BE PUT INTO | | | OPERATION WITHOUT AN INSPECTION AND OPERATION PERMIT | | | ISSUED FROM THE DOH. DOH MAY GRANT VARIANCES FROM THE | | | PROVISIONS OF THE FLORIDA BUILDING CODE SPECIFICALLY | | | PERTAINING TO PUBLIC SWIMMING POOLS AND BATHING PLACES | | | AS AUTHORIZED BY SECTION 514.0115, FLORIDA STATUTES. | | | BUILDING OFFICIALS SHALL RECOGNIZE AND ENFORCE VARIANCE | | | ORDERS ISSUED BY THE DEPARTMENT OF HEALTH PURSUANT TO | | | SECTION 514.0115(5), FLORIDA STATUTES INCLUDING ANY | | | CONDITIONS ATTACHED TO THE GRANTING OF THE VARIANCE. | | | 3. SHT.W0-0.01 GENERAL NOTES SEC H ADA COMPLIANCE #1 | | | SWIMMING POOL SHALL COMPLY WITH FBC ACC. 2014. | | | 4. PROVIDE INSTALL GUIDE AND SPEC SHEETS FOR | | | ACCESSIBILITY LIFT. | | | NOTE: OTHER ADMINISTRATIVE AND PROGRAMMATIC PROVISIONS | | | APPLY. SEE DEPARTMENT OF HEALTH (DOH) RULE 64E-9, | | | FLORIDA ADMINISTRATIVE CODE AND CHAPTER 514, FLORIDA | | | STATUTES. THE REGULATION AND ENFORCEMENT OF THE INITIAL | | | AND ANNUAL OPERATION PERMIT FOR PUBLIC POOLS ARE | | | PREEMPTED TO THE DOH. THE CONSTRUCTION PERMIT HOLDER IS | | | RESPONSIBLE FOR OBTAINING AN OPERATION PERMIT ISSUED BY | | | DOH, AS A PUBLIC SWIMMING POOL SHALL NOT BE PUT INTO | | | OPERATION WITHOUT AN INSPECTION AND OPERATION PERMIT | | | ISSUED FROM THE DOH. DOH MAY GRANT VARIANCES FROM THE | | | PROVISIONS OF THE FLORIDA BUILDING CODE SPECIFICALLY | | | PERTAINING TO PUBLIC SWIMMING POOLS AND BATHING PLACES | | | AS AUTHORIZED BY SECTION 514.0115, FLORIDA STATUTES. | | | BUILDING OFFICIALS SHALL RECOGNIZE AND ENFORCE VARIANCE | | | ORDERS ISSUED BY THE DEPARTMENT OF HEALTH PURSUANT TO | | | SECTION 514.0115(5), FLORIDA STATUTES INCLUDING ANY | | | CONDITIONS ATTACHED TO THE GRANTING OF THE VARIANCE. | | | 5. SHOW ACCESSIBILITY TO HOT SPA. SHALL COMPLY WITH FBC | | | ACC. SEC. 1009.4 | | | 6. SHT.W0-1.12 MENS SPA JACUZZI SHOWS A TOILET IN THE | | | JACUZZI THE TOILET IS MISSING IN THE BATHROOM NEXT TO | | | IT PLEASE CORRECT. | | | PERWPB AMEND. TO FBC SEC.107.2.1 | | | 7. SHT. W1-1.02 SHOW DIMENSIONS ON ALL FLOOR INLETS MAX | | | SPACING BETWEEN 20 FT MAX DISTANCE FROM ADJACENT WALL | | | 10FT TO COMPLY WITH FBC SEC.454.1.6.5.9.2 | | | 8. PROVIDE DIMENSIONS AND VOLUME OF ALL COLLECTOR TANKS | | | SHALL COMPLY WITH FBC SEC.454.1.6.5.10.5 | | | 9. PROVIDE MATCH LINES ON ALL DRAWING TO SHOW | | | CONTINUATION OF PIPING. PER WPBAMEND. TO FBC | | | SEC.107.2.1 | | | 10. PROVIDE MANUFACTURE SPECS FOR PUMPS AND OTHER | | | EQUIPMENT .MAIN DRAIN AND SKIMMERS. PER WPBAMEND. TO | | | FBC SEC.107.2.1 | | | 11. DETAILS AND PLAN VIEWS FOR WATER FEATURES ARE | | | UNCLEAR PLEASE PROVIDE COMPLETE PIPING DIAGRAMS AND | | | DIMENSIONAL DEPTH OF ALL WATER FEATURES. PER WPBAMEND. | | | TO FBC SEC.107.2.1 | | | 12. SHT. W2-4.01 REFERS TO DETAIL 8 FOR BOTH DETAILS IN | | | SEC B ONE SHOULD REFER TO DETAIL 7. PLEASE CLARIFY. PER | | | WPBAMEND. TO FBC SEC.107.2.1 | | | 13. SHOW ALL BACKFLOW DEVICES REQUIRED ON ALL FILL BOXS | | | AND AUTO FILLS. TO COMPLY WITH FBC PL. SEC.608.1 | | | 14. ONE URINAL IS REQUIRED IN MEN?S POOL BATHROOM. PER | | | FBC PL TABLE 403.6 AND SEC 403.6 | | | 15. EACH POOL BATHROOM SHALL BE EQUIPPED WITH BABY | | | CHANGING TABLE .PER FBC PL. SEC. 403.6 | | | 16. PROVIDE MANUFACTURE SPECS ON ALL POOL EQUIPMENT AND | | | CHEMICAL TANKS. PER WPB AMEND. TO FBC 107.2. | | | 17. ON ALL POOL, HOT SPA, JACUZZI, SPLASH PAD AND WATER | | | FEATURES. PLEASE SHOW CONTINUATION OF PIPING LABEL AND | | | LIST PAGE FOR CONTINUATION. PER WPB AMEND. TO FBC SEC. | | | 107.2.1 | | | 18. SHOW COMPLIANCE FOR OZONE EQUIPMENT ROOM | | | VENTILATION MUST COMPLY WITH FBC SEC. 545.1.6.5.16.4.5 | | | 19. SHOW COMPLIANCE WITH FBC SEC.545.1.6.5.16.4.6 FOR | | | SELF-CONTAINED BREATHING APPARATUS. | | | 20. CONCENTRATION OR OZONE IN THE RETURN LINE TO THE | | | SPLASH PAD SHALL NOT EXCEED 0.1MG/2 PER FBC SEC. | | | 454.1.6.5.16.4.3 | | | 21. SHT. W4-1.03 EQUIPMENT TAG # DT-301 SHALL BE | | | INSTALLED IN VERTICAL POSITION PER MANUFACTURE | | | INSTALLATION GUIDE. | | | 22. ALL CARTRIDGE FILTERS SHALL COMPLY WITH FBC | | | .1.6.5.5.1 FOR FILTRATION RATE CAPACITIES. | | | 23. ALL BACKFLOW PREVENTERS SHALL BE LEAD FREE AND | | | LISTED ON THE UNIVERSITY OF SOUTHERN CALIFORNIA LIST OF | | | APPROVED DEVICES. PER FBC PL SEC. 605.2 AND 605.2.1 | | | 24. PROVIDE MSDS SHEETS FOR ALL CHEMICALS USED. PER WPB | | | AMEND. TO FBC 107.2. | | | 25. SHT. W4-3.01 CHECK THE FLOW ARROWS @ EQUIPMENT TAG | | | CL-401 THE SCHEMATIC SHOWS THE FLOW IN OPPOSITE | | | DIRECTION@ CL-401 SHALL COMPLY WITH FBC 454.1.6.5.16 | | | 26. SHT. W4-3.01 A FIXED THERMOSTAT SHALL BE MOUNTED ON | | | IN POOL RECIRCULATION LINE DOWNSTREAM FROM THE POOL | | | HEATER OUTLET. THERMOSTAT MOUNTED ON POOL HEATER | | | OUTLETS DOES NOT MEET THIS REQUIREMENT. PER FBC SEC. | | | 454.1.6.5.14 CHECK ALL SYSTEMS FOR COMPLIANCE. | | | 27. SHT. W4-3.02 FLOW ARROWS FROM CL-501 ARE REVERSED | | | SHALL COMPLY WITH FBC 454.1.6.5.16 | | | 28. OZONE GENERATING EQUIPMENT ELECTRICAL COMPONENTS | | | AND WIRING SHALL COMPLY WITH THE REQUIREMENTS OF | | | CHAPTER 27 OF THIS CODE AND THE MANUFACTURER SHALL | | | PROVIDE A CERTIFICATE OF CONFORMANCE. THE PROCESS | | | EQUIPMENT SHALL BE PROVIDED WITH AN EFFECTIVE MEANS TO | | | ALERT THE USER WHEN A COMPONENT OF THIS EQUIPMENT IS | | | NOT OPERATING PER FBC 454.1.6.5.16.4.1 | | | 29. PROVIDE SPECS FOR CHANNEL DRAINS FOR SPA AND MAIN | | | DRAINS FOR POOL. PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 30. PROVIDE SPECS FOR STEAM GENERATOR AND SHOW WHAT IT | | | IS GOING TO BE USED FOR. PER WPB AMEND. TO FBC SEC. | | | 107.2.1 | | | 31. LABEL ALL EQUIPMENT AND CONTROLLERS ON ISOMETRIC | | | VIEWS. PER WPB AMEND. TO FBC SEC. 107.2.1 | | | 32. SHOW THE DEPTH OF ALL WATER FEATURES ON SECTION | | | DRAWING PER WPB AMEND. TO FBC SEC. 107.2.1. | | | | | | | | | DO TO THE DEFICIENCY'S AND SOME SHEETS BEING UNCLEAR A | | | COMPLETE AND COMPREHENSIVE REVIEW OF THE PLUMBING | | | SYSTEMS CAN NOT BE COMPLETED AT THIS TIME. THIS MAY | | | GENERATE MORE COMMENTS UPON SECOND REVIEW. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2016-08-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-08-29 |
Time |
17:16 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-08-29 |
Time |
17:16 |
Sent To |
|
|
| Notes |
| 2016-08-29 17:16:25 | ROOFING PLAN REVIEW | | | W. P. B. PERMIT: 15111020 | | | ADD: 1100 S. FLAGLER DR. | | | CONT: SUFFOLK CONSTRUCTION CO. | | | TEL: 561-832-1616 | | | E-MAIL: [email protected] | | | | | | 2010 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2ND REVIEW | | | DATE: MON. AUGUST 29 27/2016 | | | ACTION: BUILDING PROVISO | | | | | | 1) DEFERRED SUBMITTALS:107.3.4.2. | | | | | | , 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA | | | DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 | | | (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS | | | THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31) | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP CURBS, | | | (F) SKYLIGHTS | | | (G) PRE-ENGINEERED A/C STANDS | | | | | | 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA | | | RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN WRITING BY | | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2016-01-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-01-23 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-01-23 |
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2016-01-23 10:07:46 | ROOFING PLAN REVIEW | | | W. P. B. PERMIT: 15111020 | | | ADD: 1100 S. FLAGLER DR. | | | CONT: SUFFOLK CONSTRUCTION CO. | | | TEL: 561-832-1616 | | | E-MAIL: [email protected] | | | | | | 2010 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2010EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: WED. JAN. 27/2016 | | | ACTION: DENIED | | | | | | 1) NO PRODUCT APPROVALS WERE SUBMITTED FOR THIS REVIEW. | | | | | | , 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA | | | DEPARTMENT OF COMMUNITY AFFAIRS RULE 9N-3 NOV. 01/ 2010 | | | (31) SUB-CATEGORY OF PRODUCTS OR CONSTRUCTION SYSTEMS | | | THAT WILL REQUIRE PRODUCT APPROVALS: | | | (31) | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP CURBS, | | | (F) SKYLIGHTS | | | (G) PRE-ENGINEERED A/C STANDS | | | | | | 107.3.4.1 THOSE PRODUCTS WHICH ARE REGULATED BY DCA | | | RULE 9N-3 SHALL BE REVIEWED AND APPROVED IN WRITING BY | | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | | | | JAMES A. WITMER CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
P |
Date |
2017-02-10 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-02-10 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-02-10 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2017-02-07 12:12:00 | CCOLE, 2/7/17 | | | MECHANICAL PLAN SHEETS, ENERGYGAUGE COMPLIANCE | | | SUBMITTAL, AND AC CALCULATIONS VERIFIED. | | | | | 2017-02-06 17:06:54 | 2/6/17 PLUMBING,GAS AND POOL SHEETS OK/ GPJ | | 2017-02-06 13:50:06 | MON. FEB. 06/2017 ARCHITECTURAL & STRUCTURAL SHEETS | | | REVIEWED FOR SIGNATURE, OK. JW |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2017-02-10 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-02-10 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-02-10 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2017-01-30 10:17:04 | 3RD BUILDING REVIEW, STILL THE ARCHITECTURAL SHEETS NOT | | | SIGNED AND SEALED ELECTRONICALLY. | | | STRUCTURAL ENGINEERED SHEETS ELECTRONICALLY SEALED. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION/ DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2017-02-10 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-02-10 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-02-10 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2016-12-29 13:45:14 | 12/29 /16 | | | | | | NONE OF THE PLUMBING OR POOL SHEETS ARE DIGITALLY | | | SIGNED ALL NEED TO BE . | | | PER 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING | | | ELECTRONICALLY TRANSMITTED PLANS, SPECIFICATIONS, | | | REPORTS OR OTHER DOCUMENTS | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | | | | | | | | | | | | 2016-12-20 13:55:20 | DEC. 20/2016 THERE ARE NO DIGITAL SIGNATURES ON ANY OF | | | THE ARCHITECTURAL NOR STRUCTURAL SHEETS. ANOTHER REVIEW | | | WILL BE REQUIRED TO VERIFY NONE OF THE ARCHITECTIRAL OR | | | STRUCTURAL SHEETS HAVE BEEN CHANGED ONCE THE PLANS ARE | | | DIGITALLY SIGNED!!!!!!!! | | | STRUCTURAL CALCULATIONS NOT ELECTRONICCALY SIGNED. | | | COMPONENTS AND CLADDING REPORT COVERSHEET NOR THE TABLE | | | OF CONTENTS IS DIGITALLY SIGNED. | | | SMOKE CONTROL RATIONAL ANAYSIS REPORT COVERSHEET NOR | | | THE TABLE OF CONTENTS IS DIGITALLY SIGNED. | | | | | | | | | 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING | | | ELECTRONICALLY TRANSMITTED PLANS, SPECIFICATIONS, | | | REPORTS OR OTHER DOCUMENTS | | | | | | | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2016-03-22 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2016-03-22 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2016-03-22 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2016-03-22 17:02:11 | 1ST REVIEW: FBC 2014 5TH ED. | | | | | | PURSUANT TO FAC RULES 61G15 & 61G16, PLANS MUST CONTAIN | | | APPROPRIATE TITLE BLOCK INFORMATION, AND IF DIGITALLY | | | SIGNED AND SEAL, SUCH SHALL BE AS SET FORTH IN THE | | | RULES. ADDITIONALL, DESIGN PROFESSIONALS AND FIRMS MUST | | | BE APPROPRIATELY REGISTEREED WITH THE STATE OF FLORIDA. | | | | | | | | | STEVEN KENNEDY, CBO | | | CHIEF PLANS EXAMINER | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
1 |
Status |
P |
Date |
2016-12-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2016-12-20 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2016-12-20 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2016-12-20 13:32:32 | THRESHOLD AGREEMENT SIGNED UNDER THE FOUNDATION PERMIT | | | :15050292 AS WELL AS THE BUILDING PERMIT 15111020. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2017-02-07 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2017-02-07 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2017-02-07 |
Time |
11:34 |
Sent To |
|
|
| Notes |
| 2017-02-07 11:36:25 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 02.07.2017 | | | PERMIT NO.: 15111020 | | | ADDRESS: 1100 SOUTH FLAGLER DRIVE | | | CONTRACTOR/CONTACT: DAN PETROVIC | | | TELEPHONE NO.: 305.590.5000 | | | SCOPE OF REVIEW: NEW CONDOMINIUM BUILDING. | | | ___________________________________________ | | | | | | REVIEW STATUS: PASSED WITH PROVISOS | | | ___________________________________________ | | | | | | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | | PROVISOS: | | | | | | 1. ALL LANDSCAPE PLANS SHALL BE SUBMITTED AND REVIEWED | | | UNDER A SEPARATE LANDSCAPE PERMIT APPLICATION. | | | | | | 2. THE PROPOSED PLANTING WITHIN THE CITY'S RIGHT-OF-WAY | | | SHALL BE SUBJECT TO THE REVIEW AND APPROVAL BY THE | | | CITY'S ENGINEERING SERVICES DEPARTMENT. | | | | | | 3. PRIOR TO THE ISSUANCE OF THE LANDSCAPE PERMIT, THE | | | APPLICANT SHALL SUBMIT THE MOST RECENT APPROVED | | | LANDSCAPE PLANS AND TREE MITIGATION CHART AS A REVISION | | | TO THE TREE ALTERATION PERMIT. | | | | | | 4. PRIOR TO APPROVAL OF THE FINAL LANDSCAPE INSPECTION, | | | LANDSCAPE MATERIAL SHALL BE PROVIDED AROUND THE | | | UTILITIES (BACKFLOW PREVENTERS, DOUBLE CHECK DETECTORS, | | | ETC.) AT THE SOUTH END OF THE PROPERTY, ALONG SOUTH | | | FLAGLER DRIVE, TO MINIMIZE THEIR VISUAL IMPACT. SUCH | | | MATERIAL MAY CONSIST OF SHRUBS AND/OR GROUNDCOVER USED | | | TO DISGUISE THE UTILITIES. ADDITIONALLY, THE UTILITIES | | | SHALL BE PAINTED IN A COLOR THAT MINIMIZES THEIR | | | VISIBILITY. | | | | | | 5. A MINOR PD AMENDMENT SHALL BE SUBMITTED TO THE | | | DEVELOPMENT SERVICES DEPARTMENT - PLANNING DIVISION TO | | | UPDATE ALL PLANS PREVIOUSLY-APPROVED AS PART OF THE | | | RESIDENTIAL PLANNED DEVELOPMENT (RPD), REFLECTING ALL | | | REVISIONS THAT HAVE OCCURRED TO DATE. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2017-01-11 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2017-01-11 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2017-01-11 |
Time |
09:18 |
Sent To |
|
|
| Notes |
| 2017-01-11 09:19:35 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 01.11.2017 | | | PERMIT NO.: 15111020 | | | ADDRESS: 1100 SOUTH FLAGLER DRIVE | | | CONTRACTOR/CONTACT: DAN PETROVIC | | | TELEPHONE NO.: 305.590.5000 | | | SCOPE OF REVIEW: NEW CONDOMINIUM BUILDING. | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. THE FOLLOWING ITEMS ARE OF CONCERN AND DO NOT MATCH | | | THAT WHICH WAS APPROVED THROUGH THE MINOR PD AMENDMENT | | | ISSUED ON SEPTEMBER 9, 2015: | | | | | | A. REGARDING THE PARKING LAYOUT FOR P-2, AS SHOWN ON | | | SHEET A0.31 AND A2.0P2: | | | | | | I. STRUCTURAL COLUMNS APPEAR TO ENCROACH INTO SEVERAL | | | PARKING SPACES. | | | | | | II. PARKING SPACES ORIGINALLY IDENTIFIED ON THE | | | PREVIOUSLY-APPROVED PLANS HAVE BEEN REPLACED WITH A DOG | | | SPA AND CAR WASH; HAVE THESE SPACES BEEN RELOCATED? ARE | | | THEY BEING ELIMINATED FROM THE PARKING COUNT? | | | | | | B. REGARDING THE PARKING LAYOUT FOR P-1, AS SHOWN ON | | | SHEET A0.31 AND A2.0P1: | | | | | | I. STRUCTURAL COLUMNS APPEAR TO ENCROACH INTO SEVERAL | | | PARKING SPACES. | | | | | | II. PARKING SPACES ORIGINALLY IDENTIFIED ON THE | | | PREVIOUSLY-APPROVED PLANS HAVE BEEN ELIMINATED (1 WAS | | | REPLACED BY THE NEWLY-IDENTIFIED TURNAROUND). ARE THESE | | | SPACES BEING ELIMINATED FROM THE PARKING COUNT? | | | | | | THE FOLLOWING COMMENTS ARE NOT REQUIRED TO BE ADDRESSED | | | PRIOR TO ISSUANCE OF THE BUILDING PERMIT, AND DO NOT | | | REQUIRE MODIFICATIONS TO THE BUILDING PLANS AS PART OF | | | THIS SUBMITTAL, BUT SHOULD BE CONSIDERED AS PROVISOS: | | | | | | 1. ALL LANDSCAPE PLANS SHALL BE SUBMITTED AND REVIEWED | | | UNDER A SEPARATE LANDSCAPE PERMIT APPLICATION. | | | | | | 2. THE PROPOSED PLANTING WITHIN THE CITY'S RIGHT-OF-WAY | | | SHALL BE SUBJECT TO THE REVIEW AND APPROVAL BY THE | | | CITY'S ENGINEERING SERVICES DEPARTMENT. | | | | | | 3. PRIOR TO THE ISSUANCE OF THE LANDSCAPE PERMIT, THE | | | APPLICANT SHALL SUBMIT THE MOST RECENT APPROVED | | | LANDSCAPE PLANS AND TREE MITIGATION CHART AS A REVISION | | | TO THE TREE ALTERATION PERMIT. | | | | | | 4. PRIOR TO APPROVAL OF THE FINAL LANDSCAPE INSPECTION, | | | LANDSCAPE MATERIAL SHALL BE PROVIDED AROUND THE | | | UTILITIES (BACKFLOW PREVENTERS, DOUBLE CHECK DETECTORS, | | | ETC.) AT THE SOUTH END OF THE PROPERTY, ALONG SOUTH | | | FLAGLER DRIVE, TO MINIMIZE THEIR VISUAL IMPACT. SUCH | | | MATERIAL MAY CONSIST OF SHRUBS AND/OR GROUNDCOVER USED | | | TO DISGUISE THE UTILITIES. ADDITIONALLY, THE UTILITIES | | | SHALL BE PAINTED IN A COLOR THAT MINIMIZES THEIR | | | VISIBILITY. | | | | | | 5. A MINOR PD AMENDMENT SHALL BE SUBMITTED TO THE | | | DEVELOPMENT SERVICES DEPARTMENT - PLANNING DIVISION TO | | | UPDATE ALL PLANS PREVIOUSLY-APPROVED AS PART OF THE | | | RESIDENTIAL PLANNED DEVELOPMENT (RPD), REFLECTING ALL | | | REVISIONS THAT HAVE OCCURRED TO DATE. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2016-08-23 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2016-08-23 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2016-08-23 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2016-08-23 16:20:18 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 8.23.2016 | | | PERMIT NO.: 15111020 | | | ADDRESS: 1100 SOUTH FLAGLER DRIVE | | | CONTRACTOR/CONTACT: DAN PETROVIC | | | TELEPHONE NO.: 305.590.5000 | | | SCOPE OF REVIEW: NEW CONDOMINIUM BUILDING. | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. THE FOLLOWING ITEMS ARE OF CONCERN AND DO NOT MATCH | | | THAT WHICH WAS APPROVED THROUGH THE MINOR PD AMENDMENT | | | ISSUED ON SEPTEMBER 9, 2015: | | | | | | A. REGARDING THE PARKING LAYOUT FOR P-2, AS SHOWN ON | | | SHEET A0.31 AND A2.0P2: | | | | | | I. A PARKING TURN-AROUND NEEDS TO BE PROVIDED IN THE | | | NORTHWEST CORNER OF THE GARAGE AS THIS IS A DEAD-END. | | | | | | II. STRUCTURAL COLUMNS APPEAR TO ENCROACH INTO | | | SEVERAL PARKING SPACES. | | | | | | B. REGARDING THE PARKING LAYOUT FOR P-1, AS SHOWN ON | | | SHEET A0.31 AND A2.0P1: | | | | | | I. A PARKING TURN-AROUND NEEDS TO BE PROVIDED IN THE | | | NORTHEAST CORNER OF THE GARAGE AS THIS IS A DEAD-END. | | | | | | II. STRUCTURAL COLUMNS APPEAR TO ENCROACH INTO | | | SEVERAL PARKING SPACES. | | | | | | 2. PARKING STRIPING DETAIL SHALL BE PROVIDED. | | | | | | 3. IT IS STAFF'S UNDERSTANDING THAT THE FIRE LANE ON | | | THE SOUTH, EAST, AND NORTH SIDES OF THE BUILDING IS NO | | | LONGER REQUIRED. IT IS STRONGLY ENCOURAGED THAT THIS | | | AREA BE LOOKED AT FOR ADDITIONAL LANDSCAPING AND DESIGN | | | ELEMENTS THAT MAY NOW BE INSTALLED. | | | | | | 4. PLEASE PROVIDE THE OUTLINE OF THE TOWER ON THE SITE | | | PLAN, ENSURING COMPLIANCE WITH THE APPROVED SETBACK. | | | | | | 5. FURTHER EXPLANATION AND DISCUSSION NEEDS TO BE HAD | | | REGARDING GUEST SUITES. ACCORDING TO THE PLANS IT | | | APPEARS THAT 12 GUEST SUITES ARE PROPOSED. | | | | | | 6. PHOTOMETRIC PLANS SHALL BE PROVIDED FOR ALL EXTERIOR | | | LIGHTING, AND LEVELS SHALL NOT EXCEED 0.5 FOOTCANDLES | | | WHEN MEASURED AT THE PROPERTY LINE. | | | | | | THE FOLLOWING COMMENTS ARE NOT REQUIRED TO BE ADDRESSED | | | PRIOR TO ISSUANCE OF THE BUILDING PERMIT, AND DO NOT | | | REQUIRE MODIFICATIONS TO THE BUILDING PLANS AS PART OF | | | THIS SUBMITTAL, BUT SHOULD BE CONSIDERED AS PROVISOS: | | | | | | 1. ALL LANDSCAPE PLANS SHALL BE SUBMITTED AND REVIEWED | | | UNDER A SEPARATE LANDSCAPE PERMIT APPLICATION. | | | | | | 2. THE PROPOSED PLANTING WITHIN THE CITY'S RIGHT-OF-WAY | | | SHALL BE SUBJECT TO THE REVIEW AND APPROVAL BY THE | | | CITY'S ENGINEERING SERVICES DEPARTMENT. | | | | | | 3. PRIOR TO THE ISSUANCE OF THE LANDSCAPE PERMIT, THE | | | APPLICANT SHALL SUBMIT THE MOST RECENT APPROVED | | | LANDSCAPE PLANS AND TREE MITIGATION CHART AS A REVISION | | | TO THE TREE ALTERATION PERMIT. | | | | | | 4. PRIOR TO APPROVAL OF THE FINAL LANDSCAPE INSPECTION, | | | LANDSCAPE MATERIAL SHALL BE PROVIDED AROUND THE | | | UTILITIES (BACKFLOW PREVENTERS, DOUBLE CHECK DETECTORS, | | | ETC.) AT THE SOUTH END OF THE PROPERTY, ALONG SOUTH | | | FLAGLER DRIVE, TO MINIMIZE THEIR VISUAL IMPACT. SUCH | | | MATERIAL MAY CONSIST OF SHRUBS AND/OR GROUNDCOVER USED | | | TO DISGUISE THE UTILITIES. ADDITIONALLY, THE UTILITIES | | | SHALL BE PAINTED IN A COLOR THAT MINIMIZES THEIR | | | VISIBILITY. | | | | | | 5. A MINOR PD AMENDMENT SHALL BE SUBMITTED TO THE | | | DEVELOPMENT SERVICES DEPARTMENT - PLANNING DIVISION TO | | | UPDATE ALL PLANS PREVIOUSLY-APPROVED AS PART OF THE | | | RESIDENTIAL PLANNED DEVELOPMENT (RPD), REFLECTING ALL | | | REVISIONS THAT HAVE OCCURRED TO DATE. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | | | | 1/8/15 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2016-04-13 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2016-04-13 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2016-04-13 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2016-04-13 16:20:53 | ZONING PLAN REVIEW | | | ___________________________________________ | | | | | | DATE OF REVIEW: 04.13.2016 | | | PERMIT NO.: 15111020 | | | ADDRESS: 1100 SOUTH FLAGLER DRIVE | | | CONTRACTOR/CONTACT: DAN PETROVIC | | | TELEPHONE NO.: 305.590.5000 | | | SCOPE OF REVIEW: NEW CONDOMINIUM BUILDING. | | | ___________________________________________ | | | | | | REVIEW STATUS: FAILED | | | ___________________________________________ | | | | | | PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN | | | REVIEW COMMENTS: | | | | | | 1. ALL LANDSCAPE PLANS SHALL BE SUBMITTED AND REVIEWED | | | UNDER A SEPARATE LANDSCAPE PERMIT APPLICATION. | | | | | | 2. THE PROPOSED PLANTING WITHIN THE CITY?S RIGHT-OF-WAY | | | SHALL BE SUBJECT TO THE REVIEW AND APPROVAL BY THE | | | CITY?S ENGINEERING SERVICES DEPARTMENT. | | | | | | 3. THE ROYAL PALMS PROPOSED TO BE LOCATED WITHIN THE | | | CITY?S RIGHT-OF-WAY SHALL MATCH THE HEIGHT OF THOSE | | | CURRENTLY LOCATED ALONG SOUTH FLAGLER DRIVE, SOUTH OF | | | THE PROPOSED DEVELOPMENT; PLEASE INDICATE THIS ON THE | | | PLANS. | | | | | | 4. ALL GLASS MATERIALS SHALL BE REVIEWED AND APPROVED | | | BY THE CITY?S DEVELOPMENT SERVICES DEPARTMENT ? | | | PLANNING DIVISION, AND SHALL CONFORM TO THE FLORIDA | | | BUILDING CODE. ALL GLASS SHALL BE HIGHLY TRANSPARENT | | | AND SHALL NOT BE HEAVILY TINTED WITH A COLOR, INCLUDING | | | BUT NOT LIMITED TO BLUE OR GREEN. PLEASE CLARIFY THAT | | | GLAZING MATERIAL THAT HAS BEEN SPECIFIED AS ?SPANDREL | | | GLASS? WITH ?CHARCOAL GREY? COVERAGE. | | | | | | 5. ANY EXHAUST FANS REQUIRED FOR THE VENTILATION OF THE | | | ENCLOSED PARKING GARAGE SHALL BE DIRECTED AWAY FROM | | | ADJACENT RESIDENTIAL DEVELOPMENT SO AS NOT TO CREATE A | | | NUISANCE FROM NOISE AND/OR FUMES. | | | | | | 6. PRIOR TO THE ISSUANCE OF THE LANDSCAPE PERMIT, THE | | | APPLICANT SHALL SUBMIT THE MOST RECENT APPROVED | | | LANDSCAPE PLANS AND TREE MITIGATION CHART AS A REVISION | | | TO THE TREE ALTERATION PERMIT. | | | | | | 7. PRIOR TO APPROVAL OF THE FINAL LANDSCAPE INSPECTION, | | | LANDSCAPE MATERIAL SHALL BE PROVIDED AROUND THE | | | UTILITIES (BACKFLOW PREVENTERS, DOUBLE CHECK DETECTORS, | | | ETC.) AT THE SOUTH END OF THE PROPERTY, ALONG SOUTH | | | FLAGLER DRIVE, TO MINIMIZE THEIR VISUAL IMPACT. SUCH | | | MATERIAL MAY CONSIST OF SHRUBS AND/OR GROUNDCOVER USED | | | TO DISGUISE THE UTILITIES. ADDITIONALLY, THE UTILITIES | | | SHALL BE PAINTED IN A COLOR THAT MINIMIZES THEIR | | | VISIBILITY. | | | | | | 8. ALL LANDSCAPE MATERIAL WITHIN THE VIEW CORRIDOR FROM | | | SOUTH FLAGLER DRIVE TO THE INTRACOASTAL WATERWAY, | | | LOCATED SOUTH OF THE PROPOSED BUILDING, SHALL BE | | | MAINTAINED AT A HEIGHT SUCH THAT IT DOES NOT BLOCK THE | | | VIEWS. | | | | | | 9. SUBJECT TO THE REVIEW AND APPROVAL BY THE CITY?S | | | DEVELOPMENT SERVICES ? PLANNING DIVISION STAFF, SMALL | | | PEDESTRIAN-SCALE SIGNAGE SHALL BE PLACED AT THE NORTH | | | AND SOUTH ENDS OF THE PUBLIC WALKWAY, IN CLOSE | | | PROXIMITY TO SOUTH FLAGLER DRIVE, IDENTIFYING THE | | | WALKWAY AS BEING OPEN FOR USE BY THE GENERAL PUBLIC AS | | | WELL AS THE HOURS WITH WHICH IT IS OPEN. SUCH SIGNAGE | | | SHALL BE INSTALLED PRIOR TO THE ISSUANCE OF THE FIRST | | | CERTIFICATE OF OCCUPANCY. | | | | | | 10. THE ZONING TABLE ON SHEET A0.25 IS NOT COMPLETE. A | | | DATA TABLE SHALL BE PROVIDED INDICATING THE FOLLOWING: | | | | | | A. EXISTING/PROPOSED LAND USE AND ZONING. | | | | | | B. TOTAL ACRES OF THE PROJECT. | | | | | | C. TOTAL GROSS BUILDING SQUARE FOOTAGE. | | | | | | D. PERCENT OF OPEN SPACE, LANDSCAPING, BUILDING | | | COVERAGE & IMPERMEABLE SURFACE. | | | | | | E. DENSITY AND NUMBER OF DWELLING UNITS (RESIDENTIAL). | | | | | | F. PARKING COMPUTATIONS (PARKING REQUIRED, PROVIDED, | | | ETC.) | | | | | | G. FLOOR AREA RATIO (FAR). | | | | | | 11. THE FOLLOWING ITEMS ARE OF CONCERN AND DO NOT MATCH | | | THAT WHICH WAS APPROVED THROUGH THE MINOR PD AMENDMENT | | | ISSUED ON SEPTEMBER 9, 2015: | | | | | | A. REGARDING THE PARKING LAYOUT FOR P-2, AS SHOWN ON | | | SHEET A0.31 AND A2.0P2: | | | | | | I. A PARKING TURN-AROUND NEEDS TO BE PROVIDED IN THE | | | NORTHWEST CORNER OF THE GARAGE AS THIS IS A DEAD-END. | | | | | | II. STRUCTURAL COLUMNS APPEAR TO ENCROACH INTO | | | SEVERAL PARKING SPACES. | | | | | | III. PARKING SPACES ARE SHOWN IN THE CENTER OF THE | | | BUILDING, BETWEEN THE TWO (2) CENTRAL CORES, WHICH ARE | | | INACCESSIBLE. | | | | | | B. REGARDING THE PARKING LAYOUT FOR P-1, AS SHOWN ON | | | SHEET A0.31 AND A2.0P1: | | | | | | I. A PARKING TURN-AROUND NEEDS TO BE PROVIDED IN THE | | | NORTHEAST CORNER OF THE GARAGE AS THIS IS A DEAD-END. | | | | | | II. STRUCTURAL COLUMNS APPEAR TO ENCROACH INTO | | | SEVERAL PARKING SPACES. | | | | | | III. PARKING SPACES ARE SHOWN IN THE CENTER OF THE | | | BUILDING, BETWEEN THE TWO (2) CENTRAL CORES, WHICH ARE | | | INACCESSIBLE. | | | | | | C. A WALKWAY AND CORRESPONDING MODIFICATIONS HAVE BEEN | | | ADDED CONNECTING THE MAIN ENTRANCE TO THE PUBLIC | | | WALKWAY ALONG THE SOUTH PROPERTY LINE. | | | | | | 12. PARKING STRIPING DETAIL SHALL BE PROVIDED. | | | | | | 13. PLEASE NOTE THAT THE TEMPORARY STRIPING OF FLAGLER | | | DRIVE THAT WAS DONE AS PART OF THE FIRST BAPTIST CHURCH | | | IMPROVEMENTS IS TO BE EVALUATED TO DETERMINE IF ANY | | | ADJUSTMENTS ARE NEEDED PRIOR TO | | | MILLING/RESURFACING/STRIPING. ADDITIONALLY, PURSUANT TO | | | RESOLUTION NO. 140-14? ?TO THE MAXIMUM EXTENT POSSIBLE, | | | THE DEVELOPER SHALL WORK WITH ALL APPLICABLE | | | CONTROLLING GOVERNMENT AGENCIES FOR THE DESIGN AND | | | INSTALLATION OF A MEDIAN IN SOUTH FLAGLER DRIVE ALONG | | | THE DEVELOPMENT?S FRONTAGE. THE MEDIAN MAY CONTAIN THE | | | APPROPRIATE TURN LANES DEEMED NECESSARY. THE DESIGN OF | | | THE MEDIAN SHALL BE COMPLETE PRIOR TO THE ISSUANCE OF A | | | BUILDING PERMIT FOR THE RESIDENTIAL CONDOMINIUM, AND | | | CONSTRUCTION OF THE MEDIAN SHALL BE COMPLETE PRIOR TO | | | THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. THE | | | DEVELOPER SHALL BE RESPONSIBLE FOR ALL COSTS ASSOCIATED | | | WITH PERMITTING, CONSTRUCTION, ETC. AND SHALL BE | | | RESPONSIBLE FOR MAINTENANCE IN PERPETUITY. IF IT IS | | | DETERMINED BY THE APPLICABLE CONTROLLING GOVERNMENT | | | AGENCIES THAT A MEDIAN WILL NOT BE VIABLE, THE | | | DEVELOPER SHALL BE RELIEVED OF THIS OBLIGATION.? | | | | | | 14. IT IS STAFF?S UNDERSTANDING THAT THE FIRE LANE ON | | | THE SOUTH, EAST, AND NORTH SIDES OF THE BUILDING IS NO | | | LONGER REQUIRED. IT IS STRONGLY ENCOURAGED THAT THIS | | | AREA BE LOOKED AT FOR ADDITIONAL LANDSCAPING AND DESIGN | | | ELEMENTS THAT MAY NOW BE INSTALLED. | | | | | | 15. PLEASE PROVIDE THE OUTLINE OF THE TOWER ON THE SITE | | | PLAN, ENSURING COMPLIANCE WITH THE APPROVED SETBACK. | | | | | | 16. FURTHER EXPLANATION AND DISCUSSION NEEDS TO BE HAD | | | REGARDING GUEST SUITES. ACCORDING TO THE PLANS IT | | | APPEARS THAT 12 GUEST SUITES ARE PROPOSED. | | | | | | 17. PLEASE PROVIDE ELEVATION POINTS AS SHOWN ON THE | | | SITE PLAN APPROVED THROUGH THE MINOR PD AMENDMENT. | | | SHEET A1.01 OF THE PERMIT PLANS HAS AN ELEVATION OF | | | 22?6? FOR THE PATIO/DECK AT THE NORTHEAST CORNER OF THE | | | BUILDING; THIS IS 1?6? HIGHER THAN WHAT WAS INDICATED | | | ON THE MINOR PD AMENDMENT. PLEASE CLARIFY ANY | | | MODIFICATIONS THAT HAVE BEEN MADE SINCE THE SEPTEMBER | | | 9, 2015, APPROVAL. | | | | | | 18. NOTE, THE SPA CANNOT BE OPEN TO THE PUBLIC AND | | | SHALL ONLY BE MADE AVAILABLE TO RESIDENTS. | | | | | | 19. PHOTOMETRIC PLANS SHALL BE PROVIDED FOR ALL | | | EXTERIOR LIGHTING, AND LEVELS SHALL NOT EXCEED 0.5 | | | FOOTCANDLES WHEN MEASURED AT THE PROPERTY LINE. | | | | | | 20. DETAILS SHALL BE PROVIDED REGARDING ALL SITE | | | LIGHTING, INCLUDING POLE HEIGHT. | | | | | | 21. THE WALLS/GATES IN THE SOUTHWEST CORNER OF THE | | | PROPERTY HAVE BEEN MODIFIED SINCE THE SEPTEMBER 9, 2015 | | | APPROVAL OF THE MINOR PD AMENDMENT. | | | | | | 22. PRODUCT SPECIFICATIONS SHALL BE PROVIDED FOR THE | | | ARTIFICIAL TURF INDICATING COMPLIANCE WITH THE MINIMUM | | | STANDARDS OF SECTION 94?451 OF THE CITY?S ZONING AND | | | LAND DEVELOPMENT REGULATIONS. | | | | | | 23. THE ENTRY GATE, WALL, AND SIGNAGE HAS ALL BEEN | | | MODIFIED SINCE THE SEPTEMBER 9, 2015, APPROVAL OF THE | | | MINOR PD AMENDMENT. THERE NEEDS TO BE DISCUSSION | | | REGARDING THE IMPLICATIONS OF THIS CHANGE AND | | | COMPLIANCE WITH THE SIGN REGULATIONS OF THE CITY?S | | | ZONING AND LAND DEVELOPMENT REGULATIONS. | | | | | | 24. ON SHEET L4.10, THE PAGE REFERENCES FOR SOME OF THE | | | DETAILS ARE INCORRECT. FOR EXAMPLE, SHEET L4.10 REFERS | | | TO DETAIL 3 ON SHEET L4.50 FOR AN ELEVATION OF THE | | | PEDESTRIAN GATE CROSSING THE PUBLIC PROMENADE; DETAIL 3 | | | ON SHEET L4.50 IS THE EXIT GATE ELEVATION. ENSURE THAT | | | ALL PAGE # AND DETAIL # REFERENCES ARE CORRECT. | | | 25. THE PROPOSED FENCE/GATE MATERIALS AND SOME SIZES | | | HAVE BEEN MODIFIED FROM WHAT WAS PREVIOUSLY APPROVED, | | | AND THERE IS CONCERN REGARDING WHAT IS PROPOSED. | | | | | | 26. IT APPEARS THAT WITH MODIFICATIONS TO THE LANDSCAPE | | | PLAN, FENCING, ETC., THE VIEW CORRIDOR AND OPEN LAWN | | | AREA ON THE SOUTH SIDE OF THE BUILDING HAS ALMOST | | | ENTIRELY BEEN ELIMINATED AND NO LONGER COMPLIES WITH | | | THAT WHICH WAS PREVIOUSLY APPROVED. DISCUSSION NEEDS TO | | | OCCUR REGARDING THIS MATTER. | | | ___________________________________________ | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | ___________________________________________ | | | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | | 401 CLEMATIS STREET - P.O. BOX 3147 | | | WEST PALM BEACH, FLORIDA 33402 | | | | | | P: 561.822.1448 | | | F: 561.822.1460 | | | | | | E: [email protected] | | | | | | W: WPB.ORG | | | | | 2016-01-08 13:46:23 | 1/8/15 |
|
|
|